HomeMy WebLinkAbout20-22609 CITY OF ZEPHYRHILLS 5335-8th Street (813)78C-0020 22609 ELECTRICAL PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit#:22609 Issued: 3/19/2020 Address: 6377 COBBLE BLISS ST Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 35,457.00 Total Fees: 390.00 Subdivision: SILVERADO Amount Paid: 390.00 Date Paid: 3/19/2020 Parcel Number: 04-26-21-0110-00900-0060 CONTRACTOR INFORMATION OWNER INFORMATION Name: SUNPRO SOLAR Name: LEE, KEVIN & MAYRA Addr: 22171 MCH RD Address: 6377 COBBLE BLISS ST MANDEVILLE,LA 70471 ZEPHYRHILLS, FL 33541 Phone: (813)460-9097 Lic: Phone: 201-920-7902 Work Desc: INSTALL 30 ROOF MOUNT SOLAR PANELS APPLICATION FEES ELECTRICAL FEE 315.00 BUILDING FEE 75.00 INSPEC I NS REQUIRED ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first rinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. C TRACTOR PER OFFI PERMIT EXPIRES I MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER S U N P R ;4MV S� l SOLAR ENERGY SPECIALISTS 1,Ronnie Padgett,am the license holder of Marc Jones Co ''I L tate of �� Y•ky - ' > Florida License Number HC13001242. :- � I hereby authorize the following individuals to act as my agent and,in my absence,give authority to sign for all permits on my behalf and the behalf Marc Jones Constriction,LLC. Name Address Driver's License # Devon Conyers: . 2204 Ram Bay Rd.'Manning, SC SC DL #100557689 29102 James Veasey 7455 S Finale Pt Homosassa, FL FLDL #V200453883300 34446 Wesley 8995 60' St. N.Pinellas Park, FL FL DL#M256-896-83-46270 Macmurchy 33782 Jose Montelongo. 3506 Walter Court,Plailt.City, FL DL#M534-433-94-344-0 FL, 33563 Jordan Rhymes, 5807 Legacy Crescent PL 202, FL DL# R520-424-95-216-0 Rivel-view, FL 33578 2 Ronnie Padgett LICENSE HOLDER'S SIGNATURE PRINTED NAME STATE OF FLORIDA COUNTY OF PASCO I HEREBY CERTIFY that on this 26 day of February 20 20 before me,personally appeared Ronnie Padgett . the License Holder of record for the above-referenced company,_ who is: Personally,known to me X Produced FL DL as Identification FE4" RA JEANCROUCH k+:.ry Public-State of Florida -mmission # GG 321540y Commission ExpiresApril 9, 2023 "TIR p _.. t � .:. .. #. ,r: RTE �' A - I March 14, 2020 Kevin D.and Mayra Lee 6377 Cobble Bliss St. Zephyrhills FL 33541 NOTICE OF APPROVAL RE: 6377 Cobble Bliss St. Dear Kevin D.and Mayra Lee Congratulations!The request for an architectural change,as described below, has been approved. Ticket#19065-Solar Panels The Architectural Application to install Solar Panels on the roof of the house has been APPROVED. .00 to M oXte a, t I o 40. --IN �� ". = .o pia t . Project must begin within 90 days and be complete by 180 days after approval letter.The HOA reserves the right to make a final inspection upon completion of the approved changes to ensure compliance. Please be advised that any modifications of the original request will require an additional form to be submitted. Please remember to adhere to all local building codes and setback requirements. If a building permit is necessary, it is the responsibility of the applicant to obtain. The HOA approval is based solely on the aesthetics of the proposed change. This approval should not be j construed as a certification of the structural integrity of any construction. Be aware that it is the I responsibility tyof the applicant to contact the ap propriate utility companies prior to digging. Sincerely, I Angela Lynch Community Manager On behalf of Silverado Ranch North Homeowners Association, Inc. I I y 1 Corporate office Championsgate 1� 1631£- Vine St. I Suite 300 8390 Charripionsgate Blvd I� Suite 304 Palm Coast Ki,, m 1 s, mee,FL.34744 ChampionsQate,FL 3339G 6 Meridian Home Ln, I Suite-,,()I Palm Coast,FL 3s137 1 0,407-705.2190 1 F 407-604-630A I 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received ul Ms Phone Contact for Perlritting 1( ) if EfEEEi 'iiEEi Owner's Name KEVIN LEE Owner Phone Number 201-920-7902 owner's Address 1 6377 COBBLE BLISS ST Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6377 COBBLE BLISS ST ZEPHYRHILLS FL 33541 LOT# SUBDIVISION PARCEL ID#04-26-21-0110-0090-0060 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED ® NEW CONSTR B ADD/ALT 0 SIGN Q Q DEMOLISH INSTALL REPAIR PROPOSED USE ® SFR 0 COMM 0 OTHER TYPE OF CONSTRUCTION Q BLOCK 0 FRAME STEEL 0 DESCRIPTION OF WORK INSTALL 30 SOLAR PANELS ON ROOF OF HOME BUILDING SIZE SQ FOOTAGE HEIGHT ©BUILDING $33,957 VALUATION OF TOTAL CONSTRUCTION XDELECTRICAL $1,500 AMP SERVICE 200A 0 PROGRESS ENERGY 0 W.R.E.C. q OPLUMBING $ ro =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION 01 GAS ROOFING 0 SPECIALTY = OTHER 211FL FINISHED FLOOR ELEVATIONS FrrLOOD ZONE AREA DYES NO BUILDER 5 `'"v OMPANY� -':' -j e .7,u.�SIGNATURE v l �,RE.GIsT RED -- 'Y7-N-- 4 E7CURREN—Y`/'N Address License# ELECTRICIAN 2� COMPANY SIGNATURE ` REGISTERED I Y/N FEE CURREN Y(N Address 22171 MCH RD MANDEVILLE LA 70471 License# IEC13001242 PLUMBER COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN I Y/N Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new Construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(AIC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. _ UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid pdor to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the.Flodda Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTORWOWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in.any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT, FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR / Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by 26 y Who is/are personally known to me or has/have produced Who is/are1�err o ally known to or s/h a roduced as identification. FL UL a id tification. Notary Public Notary Public Commission No. Commission No.GG321540 SARA CROUCH Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped SARA JEAN CROUCH :Notary Public-State of Florida *E Commission # GG 321540 My Commission Expires April 9, 2023 A ..a�rro City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: C� Site: 63 -2--7 ro /z- 1; . 4 Permit Type: 1 .3 01�`f` �i hl �S f1N Yav 04c Approved w/no comments: Approved w/the below comments: O Denied w/the below comments: O This commeV sheet sh ll be kept with the permit and/or plans. y . MAR I.0 2020 Kalvi zer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) INSTR#2020025238 OR SK 10053 PG 1 Pa9e 1 of 1 02/1412020 08:13 AM Rcpt.2135407 Rec:10.00'DS:0.00 iT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller r Permit Number f Parcel ID Number NOTICE OF COMMENCEMENT State of Florida County of THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property,and In accordance with Section 713.13 of the y Florida Statutes,the following information Is provi=,jkrejgjp is NOTICE OF COMMENCEMENT. 1.Description of property(legal description)., Yczvvao ub . ha ie- EA N 4 J$ PG 033 131 LOI-i"�, a)Street(fob)Address: 63 7 7 CobbLe _13laGc 7 k S 2.Generai description of improvements: INSTALL SOLAR PV SYSTEM . i 3.Owner Information or Lessee information if the Lessee contracted for the Improvement: a)Name and address: kAzt,%" &3 7 of 1.p f3.cc s e Zell ac t 3 S 4 t b)Name and address of fee simple tilfeholder Of different than Owner listed above) NIA c)interest in property: 100% 4.Contractor Information a)Name and address: Ronnie Padgett,Marc Jones Construction,LLC dba Sunpro Solar-4654 Eagle Falls PL Tampa FL 33619 b)Telephone No.: 866.450.1012 Fax No.:(optional) NIA $.Surety(if applicable,a copy of the payment bond Is attached) a)Name and address: N/A b)Telephone No.: c)Amount of Bond: S S.Lender a)Name and address: N/A b)Telephone No.: 7.Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section ? 713.13(1)(a)7„Florida Statutes: a)Name and address: NiA _ b)Telephone No.: Fax No.:(optional) S.a.ln addition to himself or herself,Owner designates NrA of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. b)Phone Number of Person or entity designated by Owner: 9.Expiration date of notice of commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but wig be 1 year from the date of recording unless a different date is specified): ,20 WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE ! CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. iF YOU INTEND To OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN } ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penally of perjury,i declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge d belle(. acute of Ownep of Less ,ar 0wnWz po C ee's(AuUw+lzed 0flicae@uectoelParlow lanagep) (Pilnt Name and Floft SlgnaIW&TI1a10tgea) I Th a oing(rtstrument was acknowledged before me this day of �y 1 20 2j--- by _� as _— — (type of auUwtlly aA.ot➢uer,trustee,attapneyln fact) for ,as C)WY\O.v— s (Name of Person) (type of authority,...e.g.officer,trustee,attorney In fact) , for (name of parry on behalf of whom instrument was executed). 'orsanally Known ❑ Produced ID type of iD DL Notary Signature �•r— Print name "J'�'�'n,. SARA JEAN CROUCH `� Notary Puhiic•Stato of Fiaride *'c Commission N GG 321640 j ':3r,,so�P•' My Commission Expires A ri!9 �023 i DocuSign Envelope ID:EF61MEF-61D294ME-931D0-FE91C2318334 1 of hse O1// w•.0.ia S U N R SOLAR ENERGY SPECIALISTS CONTRACT PHOTOVOLTAIC ARRAY INSTALLATION Date: 1/23/2020 This Contract("Contract") is hereby entered into by and between Kevin Lee (hereinafter collectively referred to as"Owner"), and Marc Jones Construction LLC, doing business as Sunpro Solar(Hereinaf- ter referred to as"Sunpro".), 6377 Cobble Bliss Street Job Address Zephyrhills FL (City) (State) We, Owners, hereby contract with Sunpro, for the following described work, and authorize Sunpro to furnish all necessary material, labor and workmanship to install, construct, and place improvements according to the specifications, terms and conditions hereinafter described, at/on our residence. This contract document represent the entire agreement of both parties and supersedes any prior oral or written agreement.Any changes to this Contract must be approved by Sunpro in writing. Both parties agree that no verbal agreements will be recognized. SCOPE OF WORK Install a photovoltaic solar system (the"System)at the Owner's residence comprised of the following components; Major System Components Photovoltaic Panels Qty.— 30 Model: LG 335 Inverters Qty.— 30 Model: Enphase The purchase of any Enphase microinverter will include the installation of the Envoy energy management system with lifetime free online monitoring access provided by Enphase. Racking and Mounting Equipment Unirac Solar Mount rail system with PV Quickmount flashing system DS DS Initialed by: Owne Contracto tr Sunpro Solar 866-450-1012 www.gosunpro.com DocuSign Envelope ID:EF61 ASEF-61D294ME-931D0-FE91 C2318334 2 of 3 U Sblar ArrayInstallation U N P R I-1 SOLAR ENERGY SPECIALISTS DUTIES OF SUNPRO •Sunpro shall obtain all county and city permits necessary for the system to be installed. • Furnish current general liability and worker's compensation insurance upon request. • Install System to comply with all applicable codes and wind zone requirements, including 180 mph wind zone. •Sunpro shall remove all construction debris and leave the project in a broom clean condition. •Once homeowner has paid in full, Sunpro will issue all product&labor warranties and a power production guarantee to the Owner based on shade analysis performed at the time of the system installation. Sunpro will also complete the Monitoring system if applicable and will assist the Owner with entering into an Interconnect Agreement between Owner and the applicable utility company. OWNER •The Owner will have no control over or charge of installation means, methods,techniques, sequences, procedures, or for safety precautions and programs in connection with the installation of the System, since these are solely Sunpro's responsibility. •Owner is responsible for obtaining any approvals necessary from their Homeowners Association. •Owner will provide access point for Enphase envoy to connect to home internet service through a wired connection.This is typically done through the home's router. Owner will provide WIFI internet access to take advantage of Enphase's monitoring system. •Owner recognizes that Sunpro Solar is not qualified to offer any tax or legal advice. Owner should consult with a CPA or a qualified tax advisor to ensure owner receives any local, state or federal incentives that may be available. • Owner acknowledges that the federal incentive for costs associated with qualified solar property is in the form of a nonrefundable TAX CREDIT. UNKNOWN CONDITIONS Sunpro is not responsible for conditions that are encountered at the installation site which are concealed physical conditions or unknown physical conditions of an unusual nature, which differ naturally from those ordinarily found to exist. Sunpro is not responsible for existing electrical service deficiencies that mayor may not be code compliant. Existing electrical service components, including but not limited to, breaker boxes/panels, disconnects, meters, fuse boxes, wiring, conduit and all other necessary components to energize an existing structure are not the responsibility of Sunpro. At the sole discretion of Sunpro, Sunpro may cancel this Contract due to (i) any conditions encountered that impact the performance, installation or code requirements of the System's installation, or(ii) any other conditions that impact the safe and effective installation of the System. ARBITRATION AND LEGAL Any controversy or claim arising out of or relating to this Contract, or the breach thereof, shall be settled by arbitration administered by the American Arbitration Association under its Construction Industry Arbitration Rules, and judgment on the award rendered by the arbitrator(s) may be entered in any court having jurisdiction thereof. In the event of any arbitration or litigation relating to this Contract, the prevailing party shall be entitled to reasonable attorney fees, costs and expenses. If any amounts due under this contract are not paid when due, any such unpaid balances shall be charged interest at the rate of 1 1/2 %per month which is an annual percentage rate (APR) of 18%per year. CLASS ACTION WAIVER Arbitration shall proceed solely on an individual basis without the right for any Claims to be arbitrated on a class action basis or on bases involving claims brought in a purported representative capacity on behalf of others.The arbitrator's authority to resolve and make written awards is limited to Claims between Owner and Sunpro alone. Claims may not be joined or consolidated unless agreed to in writing by all parties. DS L-�Fi Initialed by: Owne �Contracto Sunpro Solar 866-450-1012 www.gosunpro.com DocuSign Envelope ID:EF61A8EF-6D29-4ME-93D0-FE91 C2318334 3 of 3 S U N P R Naigr Solar Array Installation ' SOLAR ENERGY SPECIALISTS PAYMENT TERMS Total Contract Price: $ 35,457.00 Rebate: $ 4,000.00 Customer Final Price: $ 31,457.00 Contract is contingent upon Owners approval for financing: , ❑ YES ❑NO Finance Partner: service Finance Loan Years: 20 Years Loan Interest Rate: 4.99% CASH TERMS Draw 1: Initial down payment at contract signing ( %): $ 0.00 Draw 2: 2nd Payment upon start of work ( %): $ 0.00 Draw 3: 3rd Payment upon completion of work* ( 0/0): $ 0.00 *Final payment for the solar energy system is due immediately upon passing of inspection and before utility tie-in. Contract Contingencies: You, the buyer, may cancel this transaction at any time prior to midnight of the third business day after the date of this transaction. See the attached notice of cancellation form for an explanation of this right. DocuSigned by: 1/2 3/2 0 2 0 9eM Oat Signature Date Kahlee Rollitt Sunpro Agent Print DocuSigned by: II . L�- 1/23/2020 �t�A.11A, PT �9i nature Date Kevin Lee Print Name Owner's Signature Date Print Name Sunpro Solar 866-450-1012 www.gosunpro.com License AL#06642,AZ#323436,AR#M-9565, FL#EC13001242, LA#49417, MS#21374, NM#395254, NC#U.32923, OK#186549. PROJECT DESCRIPTION• SHEET INDEX Castillo A-00 PLOT PLAN&VICINITY MAP• N PROJECT SITES EngineeMng�( 30x335 LG335N1C-V5(335W)MODULES A-01 SYMBOLS&SYSTEM DESCRIPTION S-01 ROOF PLAN&MODULES DESIGNED TO PEUMIT• ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES CASTILLO ENGINEERING S-02 STRUCTURAL ATTACHMENT DETAILS K SERVICES,LLC SYSTEM SIZE: 10.05 kW DC STC E-01 ELECTRICAL LINE DIAGRAM SERVICES. ARRAY AREA#1:55.32 SQ FT. E-02 WIRING CALCULATIONS 29ss w.STATE ROAD 434, sITER ARRAY AREA#2: 110.64 SQ FT. E-03 SYSTEM LABELING s LONG suITE 111 32779 TF (407)2Se-zs75 ERM0CRATES E.CASTILLO-FL PE 52590 FT. SQ ARRAY AREA#3:221.28 ARRAY AR EA#4: 165.96 SQ FT. DS-01 MODULE DATA SHEET DS-02 INVERTER DATA SHEET REVISIONS EQUIPMENT SUMMARY �� II DS 03 COMBINER BOX DATA SHEET DESCRIPTION a4TE REV 30 LG335N1C-V5(335W)MODULES 1g DS-04 RAIL DATA SHEET 30 ENPHASE IQ7-60-2-US MICROINVERTERS DS-05 ATTACHMENT DATA SHEET PROJECT INSTALLER UI PR• o ` ROOF#4 � G A ` / (09)LG335N1C-V5(335W) '• •• '' V/ MODULES 52590 it 2 HOUSE PHOTO �� • STA OF ' j A-00 SCALE:NTS i _ . CODES FLORIDA BUILDING CODE, o P••• NATIONAL ELECTRIC CODE, AND THE CiT`t OF ZEPHYRHILLS ,if•>f. � PROJECT SITE QINP A . _ 2-STORY 0Lu u) 3 HOUSE U M LLI m LL ROOF#1 ' # ° (E)MAIN DISTRIBUTION (03)LG335N1C V5(335W) CD J J PANEL MODULES m J �`'� L,L W 2 ROOF#3 _ 0 I W k (12)LG335N1C—V5(335W) ` J 2 MODULES T ROOF# s' cHLDQUN. 2 .9 EXISTING a- � ,©q (06)LG335N1C-V5(335W) �•O DRIVEWAY MODULES f fix , •p,,� SHEET NAME PLOT PLAN & GOVERNING CODES. (�A ' VICINITY MAP FLORIDA RESIDENTIAL CODE,6TH EDITION 2017(FRC) ✓ rf FLORIDA PLUMBING CODE,6TH EDITION 2017(FPC) FLORIDA BUILDING CODE,6TH EDITION 2017 EDITION(FBC) �� Q���✓ SHEET SIZE FLORIDA MECHANICAL CODE,6TH EDITION 2017(FMC) � l�� �/ _ ANSI B NEC 2014 CODE BOOK ; I�:1 FLORIDA FIRE PREVENTION CODE,6TH EDITION 2017(FFPC) I, X 17" WITH ROOF PLAN COPYRIGHTED BY CASTILLO 3 VICINITY MAP SHEET NUMBER 1 PLOT PLAN SCALE.NTS A-00 A_0O SCALE:1/16"=1-0" � �7. ENGINEERING SERVICES, LLC A-00 1 Castillo Engineering Symbols: Abbreviations: DESIGNED TO PERMIT• Sheet where CASTILL0 ENGINEERING Section.............. x section is located SERVICES,LLC x-xx AC Alternating Current " 2925 W.STATE ROAD 434, SUITE 111 LONGWOOD.FL 32779 Detail ID Letter APPROX Approximate TEL(407)259-2575 ERMOCRATES E.CASTILLO-FL PE 52590 Elevation........... x-XX Sheet where section is located AWG American Wire Gauge System Description REVISIONS Detail ID Letter DESCRIPTION DATE REV x CB Combiner Box Detail................ x Sheet where This system is a grid-tied, PV system, with PV generation consisting of 30 section is located DC Direct Current LG335N1C-V5 (335W) MODULES with a combined STC rated dc output power of i Detail ID Letter Detail................ x —.—Area to be enlarged DCD Direct Current Disconnect 10,050W. The modules are connected into 30 ENPHASE 1Q7-60-2-US MICROINVERTERS. (Enlarged Plan) x-'a Sheet where DISC Disconnect The inverter has electronic maximum power point tracking to maximize energy section is located captured by the PV modules. The inverter also has an internal ground fault detection PROJECT INSTALLER(E) Existi Keyed Notes.......... 1 Keyed note designation sting and interruption device that is set to disconnect the array in the event that a ground on applicable sheet EL Elevation fault that exceeds one ampere should occur. The inverter has DC and AC disconnect integrated system and labels areprovided as required by the National Electric Code Ground Terminal..... O EQ Equal g y q JB Junction Box pSeaI Grounding Point/rod.... ,IR. MCB Main Combiner Box �` C TI,LOI,,� MFR Manufacturer PV Modules Solar Panel......... or Box o 5259 ••; OOMicrolnveers Utility '1�ModulewithSource MIN Minimum rt � Polntof Circuit number JUo MISC Miscellaneous Connection * STAT OF Combiner Box.......... CB � •' ' (N) New Utility Meter QT OCPD OverCurrent Protection Device " DC Disconnect.......... DCD P0CC Point Of Common Coupling H- d When the sun is shining, power from the PV array is fed into the inverter, where I, Main Distribution MDP PV Photovoltaic it is converted from DC to AC. The inverter output is then used to contribute to the v to 2 Panel ...................... SF Squarefoot/feet power requirements of the occupancy. If PV power meets the requirements of the w m 11 loads of the occupancy, any remaining PV power is sold back to the utility. When w o cry Fuse ...................... STC Standard Test Conditions U) utility power is available, but PV power is not available, building loads are supplied by wW m TBD To Be Determined the utility. OvercurrentBreaker.. TYP Typical The inverter meets the requirements of IEEE 1547 and UL 1741. This means that W if it detects a loss of utility power, it will automatically disconnect from the utility. w VIF Verify In Field When utility voltage is restored, the inverter automatically reconnects to the utility Co N Inverter.................... WP Weather Proof grid after verifying utility voltage and frequency stability. 17 �p10 On a day with average Florida sunshine, this system outputs 38.61kWh per day Transformer............. . SHEET NAME on site. SYMBOLS& SYSTEM Automatic............... ATs DESCRIPTION Transfer Switch SHEET SIZE ANSI B 11" X17" COPYRIGHTED BY CASTILLO SHEET NUMBER ENGINEERING SERVICES, LLC A-01 MODULE TYPE, DIMENSIONS & WEIGHT NOTE:- $ GENERAL INSTALLATION PLAN NOTES: Castillo �A NUMBER OF MODULES=30 MODULES FIRE ACCESS AND PATHWAYS AS PER NFPA 11.12.2" (1)ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED AS Engineering MODULE TYPE=LG335N1C-V5(335W)MODULES �O SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE: DESI°NED To PERMIT• WEIGHT=37.69 LBS/17.1 KG. \P CASTILLO ENGINEERING MODULE DIMENSIONS=66.4"x 40"=18.44 SF '� G WIND ZONE 1:6'-0"O.C. SERVICES,LLC UNIT WEIGHT OF ARRAY=2.04 PSF S WIND ZONE 2:4'-0"O.C. WIND ZONE 3:2'-0"O.C. 2925 w.STATE ROAD 434, ARRAY & ROOF AREA 18"FIRE ACCESS E.W. sOOD i» WIND ZONE 3(TYP.) LorrGwooD,FLszns TEU(,07)289-2575 WIND ZONE 2(TYP.) SEE SHEET S-02 FOR SUPPORTING CALCULATIONS. E2MOCRATES E.CASTILLO-FL PE 52590 CALC'S (ROOF #1) WIND ZONE 1 (TYP.) REVISIONS ARRAY AREA= 55.32 SQ.FT. ROOF#4 2)EXISTING RESIDENTIAL BUILDING IS AN ASPHALT SHINGLE ROOF DESCRIPTION DATE REV ROOF FACE AREA= 172.31 SQ. FT. (09)LG335N1C-V5(335W) WITH MEAN ROOF HEIGHT 25 FT AND SYP 2X4 WOOD ROOF 55.32/172.31 =32.10%OF ROOF MODULES is TRUSSES SPACED 24" O.C. EXISTING ROOF SLOPE FOR SOLAR FACE AREA COVERED BY ARRAY SYSTEM RETROFIT IS 26.6 DEGREES. CONTRACTOR TO FIELD DESCRIPTION (ROOF #1) ° VERIFY AND SHALL REPORT TO THE ENGINEER IF ANY �60 0 5 ! DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD ROOF TYPE-ASPHALT SHINGLE ROOF �O�.`� �0 3' FIRE ACCESS FROM RIDGE CONDITIONS. ROOF TILT -26.6° c����,.' ROOF AZIMUTH-60° P�' ° I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN PROJECT INSTALLER TRUSSES SIZE-2"X4"@ 24"O.C. COMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3. BUILDING STRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFT ARRAY & ROOF AREA WIND LOADS,AND EQUIPMENT DEAD LOADS. • N P R• CALC'S (ROOF #2) F16 ARRAY & ROOF AREA ARRAY AREA= 110.64 SQ. FT. ROOF FACE AREA=238.42 SQ. FT. ROOF#1 CALC'S (ROOF #4) `� • 110.641238.42=46.41%OF ROOF • (03)LG335N1C-V5(335W) 35W) ARRAY AREA= 165.96 SQ. FT. �!.'•.•' E•N S FACE AREA COVERED BY ARRAY � : MODULES ROOF FACE AREA=729.92 SQ. FT. = � 165.96/729.92=22.74%OF ROOF p 0 DESCRIPTION (ROOF #2) FACE AREA COVERED BY ARRAY * ROOF TYPE-ASPHALT SHINGLE ROOF ROOF TILT -26.6° L�� ". ROOF#2 DESCRIPTION (ROOF#4) _ * ; ROOF AZIMUTH-150° (06)LG335N1C-V5(335W) ROOF TYPE-ASPHALT SHINGLE ROOF •: TATE OF '� MODULES ROOF TILT -26.6° TRUSSES SIZE-2"X4"@ 24"O.C. 1 1 • ,� ROOF AZIMUTH-330° •••• 4 TRUSSES SIZE-2"X4"@ 24"O.C. PROD Ci' ,• `,�� _ ARRAY & ROOF AREA 40„ CALC'S (ROOF #3) ARRAY AREA=221.28 SQ. FT. ROOF FACE AREA=384.30 SQ. FT. 221.28/384.30=57.58%OF ROOF ` d w AREA M FACE COVERED BY ARRAY DESCRIPTION (ROOF #3) �' w m i (66)PV ROOF ATTACHMENT ROOF TYPE-ASPHALT SHINGLE ROOF c 5 W @ 48"&72"O.C. MAX W ROOF TILT -26.6° W J ROOF AZIMUTH-240° . F' co (N)(30)ENPHASE IQ7-60-2-US m = TRUSSES SIZE-2'�C4"@ 24"O.C. c'0 ti1�p MICROINVERTERS w 0 9f, �� ' (N)UNIRAC RAIL(TYP.) LG335N1C-V5 w 0 >- (N)SOLADECK(TYP.) (335W) MODULES J ti a (E)UTILITY METER � 1"PVC CONDUIT RUN LEGEND CO N M W (E)MAIN DISTRIBUTION PANEL (N)AC DISCONNECT(IF REQUIRED ® -UTILITY METER Q c, P,0�•� BY UTILITY) S® -SOLADECK (N)PV METER(IF REQUIRED) lCB -COMBINER BOX SHEET NAME (N)ENPHASE IQ COMBINER BOX '� R' 1 ACo -AC DISCONNECT ROOF PLAN & O .�Q X36 F ROOF#3 l \OO 26 9-p O 0 -PRODUCTION METER MODULES (12)LG335N1C MOD ,\p ULES yNO' 2 P`� MDP -MAIN DISTRIBUTION PANEL A\ SHEET SIZE G�O\V INV -INVERTER ANSI B ��l \ O❑ -VENT,ATTIC FAN(ROOF OBSTRUCTION) 11"X 17" 0 -PV ROOF ATTACHMENT I ROOF PLAN & MODULES COPYRIGHTED BY CASTILLO -TRUSSES SHEET NUMBER S-01 SCALE:3/32"=1'-0" ENGINEERING SERVICES, LLC --- -CONDUIT S-01 • Castillo CHANNEL NUT 1s9 1 us Engineering 1 sae DESIGNED TO PS[MIT• 159 129 UNIRAC L-FOOT CASTILLO ENGINEERING SERVICES,LLC r ... "" COA#28395 br 2925W.STATE ROAD 434, SUITE 111 SOLAR MODULE 14e ' a 149 LONGWOOD,FL 32T79 159 .., TEL(4Dn X2575 GROUNDING END CLAMP FRMOCRATES E.CASTILLO FLPE52590 rr REVISIONS UNIRAC RAIL 149 r w. DESCRIPTION DATE REV 11 160 ASPHALT SHINGLE ROOF w'.. «mow 139 1. w....M 9w 1M1 FLASH KIT PRO FLASHING ,ar w•&a.r w"•a..pv.1,R,. n.y. 2"X4"TRUSSES @24"O.C. 2• ""'aieM+i°aao ii°""•"'°'" 169 "" 3. wow*ad cwt i WON so"aM' (E)ROOF SHEATHING 111111 w 1111"""1 'p"1111' .. 2"X4"MISSED TRUSS SPANNER """"'�t"'ODOM 1111'' 379 PROJECT INSTALLER (IF REQUIRED) :+ W erw I.'— rr eai4 s- 11119 ti.... 5.7s "."► r MO.78'11111).,.. 5/16"DIA.X 3"MIN. EMBEDMENT LAG SCREW •," ture wm Seal AT EACH ATTACHMENT POINT t1 ���� C A i�� INTO EXISTING FRAMING ( .•(% .. O,�i GROUNDING MID/END CLAMP �t 7EDE$16NWM13$l $.f�y�cf0kf ClltEti01C7Ni1 DMili#MR16tlI�E!$ E �li�. \ . c Wind ed Lit h Risk Cate 5 5 9 0 1 ATTACHMENT DETAIL UNIRAC RAIL Wind SpeedASD( h) •• S-02 SCALE-NTS ro Cate = •!r f Me n Roaf Hei ft Roof 9 de s iem+m Upiift Per E O F Module Area(sq ft) "fastener Wind Zone 1 UNIRAC L-FOOT Ktt 1 PerAm wkwWoodCoua - ��i •� ��� Height Adjustment Factor,A 1 NDi Il�rr YYithdraw load fodlr t ` ! 5/16•LA with huh 2.5' Embedment 'Roof attachements w 2 rails at itc/C W 1 19:4 -20.7 C/) th 2 19.4 -X3 z (/1 FLASH KIT PRO FLASHING 3 19.4 243 Maednlum Uplift per W J LL 'fastenerWindtonez 26_'3 0 - W U) ROOF SHEATHING PerAmericaa Wood Carndi- J J P net=4AKI_ztP_(net(30)): NOS MaxVA#dfaw load for 4 L Im — s/16`LAC with,2.5" 1 19.4 Embedment J 0 III 2 19.4 'Roo attadremeaes w 2 ratis at ft O/C 3 19.4 () W co N Maximum Uplift per 133.7 LO�© •fastener WInd torte 3 Q 1 L !l Per American Wood Council " 1 NDS Max Withdraw Load for SHEET NAME 2"x4"TRUSS SPANNER 5/16`1Atwih2s' 476 STRUCTURAL FOR MISSED TRUSS ATTACHMENT Ent ATTACHMENT (IF REQUIRED) 'Roofattad+enten1sw2ra[icats fto/C DETAILS 2"X 4"TRUSSES @ 24"O.C. SHEET SIZE ANSI B 5/16"DIA.X3"MIN. 4 " X 17" EMBEDMENT LAG SCREW 2 ATTACHMENT DETAIL (ENLARGED VIEW) AT EACH ATTACHMENT POINT COPYRIGHTED BY CASTILLO SHEET NUMBER INTO EXISTING FRAMING S-02 SCALE: NTS ENGINEERING SERVICES, LLC S-02 SOLAR ARRAY10.05 kU1FDC STC) Castlll U f (30) LG335N1C-VS(335W)MODULES Engineering (02) STRING OF 15 MODULES - - - - - - - - - - DESIGNED TO!llMiT• NOTE: CASTILLO ENGINEERING I QCABLEs 1.SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET SERVOIC# LLC THE REQUIREMENTS OF THE NEC 2014,AND THOSE SET 2925 W.STATE ROAD 434, _ _ _ _ - - _ - - _ - ti ti ti ti ti ti ti ti ti ti ti ti ti FORTH BY THE FLORIDA SOLAR ENERGY CENTER ����� CERTIFICATION, INCLUDING MAXIMUM NUMBER OF LONGWOOD,R 327J9 MODULE STRINGS,MAXIMUM NUMBER OF MODULES PER TEL(w_nLLO-6 ERMOCRATES E.ChSTiLLO-FL PE 5259D STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER REVISIONS ENPHASE IQ7-60-2-US AND MODEL NUMBER, INVERTER MANUFACTURER AND MICROINVERTERS MODEL NUMBER,AS APPLICABLE DESCRIPTION DATE REV PV MODULES 2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PROVIDE GROUNDING ELECTRODE PANEL GUTTER SPACE IS INADEQUATE. CONDUCTOR CONTINUOUS, NON-SPLICED AND BONDED TO METAL CONDUIT AND EACH END OF INTERCONNECTION METAL ENCLOSURES 250.64 120%RULE-NEC 705.12(D)(2)(3)(b) UTILITY FEED+SOLAR BACKFEED 200A+40A=240A PROJECT INSTALLER PROVIDE GROUNDING ELECTRODE BUSS RATING x 120% CONDUCTOR FROM THE ARRAY TO AN 200A x 120%=240A EXISTING SERVICE GROUNDING AI ELECTRODE PER 690.47(C)(3) TO UTILITY GRID (N)SOLADECK 600 V,NEMA 3R UL LISTED �Ll �L2 N , • L1 L (N)BI-DIRECTIONAL � ••C • S •O (N)AC DISCONNECT: 240V,60AMP UTILITY METER '• (N)125A ENPHASE IQ COMBINER 3 1-PHASE,240V N 5 590 GLi (X-IQ-AM1-240-3)[WITH UPTO(4) NEMA 3R,UL LISTED, 2-POLE BREAKERS AND ENVOY (N)PV METER LOCABLE AND NON-FUSIBLE COMMUNICATION GATEWAY] (IF REQUIRED) (IF REQUIRED BY UTILITY) L1 L2 N (E)MAIN DISTRIBUTION L1 L2 N PANEL,200A RATED, T TE L1 u u L1 L1 (E)MAIN BREA �. • Lz o o L2 L2 200Al2P,240V J . ��� N _ �tttFlilllll��``` (2)1212 ROMEX RUN IN ATTIC — — G — — G G — — — — G —•— G 10A (3)#6 AWG THWN-2 O co M I (1)#6 AWG THWN-2 GND IN 1"PVC OR EMT U_z: L1 W J Li.. CONDUIT RUN m L4 L1 -j - (2)#12 AWG THWN-2-RED (2)#12 AWG THWN-2-BLACK w m = (1)#6 AWG THWN-2 GND 40A/2PO IN PVC OR EMT L1 W >- L1 LU 1" (N)JUNCTION BOX CONDUIT RUN L2 J O I j I 600 V,NEMA 3 ULLISTED I CO N 20A/2P N qq L1 L1 L1 L - - - - G �OLO r20A/2P L1 L1 SHEET NAME Lz EIS TNG G OUSTING ELECTRICAL - - - LINE DIAGRAM L - - - - - - - G - - - G - - - [ j G SHEET SIZE ANSI B ELECTRICAL LINE DIAGRAM COPYRIGHTED BY CASTILLO 11"X 1711 SHEET NUMBER E-01 SCALE: NTS ENGINEERING SERVICES, LLC E-01 AC CONDUCTOR AMPACITY CALCULATIONS: AC CONDUCTOR AMPACITY CALCULATIONS: •Castillo FROM ROOF TOPSOLADECKTOLOADCENTER FROM AC COMBINER BOX TO MSP Engineering DESIGNED TO P[RMIT- LG CASTILL0 ENGINEERING LG335N 1 C-V5 VOC 41 )ec 1 t1,49 ELECTRICAL NOTES SERVICES,LLC ENPHASE VMPP 34.1 IMP 9",$3 OA0283/5 * 2925 W.STATE ROAD 434, ENPHASE IQ 7 TO Voc -0,2796/°C TC VMP 035961°r; 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND15 SUITE 111 LABELED FOR ITS APPLICATION. LONGWOOD,FL 32779 PMP 335.0 NDCT 45 °C TEL:(4D7)z25T5 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 ERMOCRATES E.CASTILLO-FL PE 52M 1 005 DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR . REVISIONS 240V 1-PHASE 75 DEGREE C. DESCRIPTION DATE REV 3. THE WIRES ARE SIZED ACCORDING TO NEC 110.14. 1-1-PH4. WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS OUTPUT VOLTAGE4QL-t..- SHALL BE ROUTED DIRECTLY TO,AND LOCATED AS CLOSE AS MIN. AMBIENT TEMP. °> MAX INPUT Dc VOLTAGE s De POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. CALCULATEDX. AMBIENT TEMP._F OPERATING AGERAN RANGEE 16.-40° .Voc 5. WORKING CLEARANCES AROUND ALL NEW AND EXISTING MAX. VOID MPPT VOLTAGE 27 37VOC � ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. MAX INPUT POWER 5c VA CALCULATED MIN VMP- START VOLTAGE ;22 wo 6. DRAWINGS INDICATE THE.GENERAL ARRANGEMENT OF SYSTEMS. ' CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, N UMBER-IIF CONDUITS CONTINUOUS AC POWER 240 VA SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE PROJECT INSTALLER CODES AND STANDARDS. 1.25 x 90 °C AMBIENT TEMP CONDUIT FILL DEBATED MAXIMUM CIRCUIT 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS R CIRCUIT MAX AMPS AWC3 ARE NOT SPECIFIED,THE CONTRACTOR SHALL SIZE THEM MAX AMPS AMPACITY TEMP F DEBATE FILL DEBATE AMPACITY BREAKER ACCORDINGLY. R 8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED CIRCUIT 1 15.0 30 0.96 0•$ AND READILY VISIBLE. i, CIRCUIT 2 15 0 1 2 30 0.96 4 0.B 20___A ¢ 9• MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE ����� C . 'L ',�� ADS a FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP ` S•'•. � MANUFACTURER'S INSTRUCTION. .. 3D.D = �_ 75 ��� �� � 1 �'��_ 2590 PANEL k7lratct � 0.96 �.,.�r, • 10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. - 11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE . 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL S ATE F PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. .1 CIRCUIT AWS CIRCULAR I V MAXMILLS LENGTH 13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 9CIRCUIT 1 6530 15.0 240 •' �`� 14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. CIRCUIT 2 6530 15.0 240 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS COMBINER PANEL OUTPUT. 26240 30.0 240 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6(C)(1)AND ARTICLE I- 310.10(D). (A LO 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE U (I) M FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10(C). Z J EMP AERATE BASED ON NEC TABLE 310..15(B)(2)(A) W 11' CONDUIT FILL DEBATE BASED ON NEC-TABLE 310.1 5(51(3)(A) C/) VJ Cl) 1NAXIMUM VOID CALCULATED USi4$MODULE MANUFACTURE TEMPERATURE COEFFICIENTS PER NEC 690.7(A) J UNLESS OTHERWISE SPECIFIED. ALL WIRING MUST BE THHN OR THWN-2 COPPER ENPHASE IQ7-60-2-US MICROINVERTER O CL) ALL WIRE SIZES LISTED ARE THE MINIMUM ALLOWABLE Input Data(DC) W O fY IN ANY CELL INDICATES THAT THE SYSTEM 45 SAFE AND COMPLIES WITH NEC REQUIREMENTS Recommended Input Power(STC) 235-350W+ J U = ra IN ANY CELL iNOICATEH.wPOTEP.IFLRLCY UNSAFE CONDITION Maximum Input DC Voltage 48V � INFORMATION INPUT BY SYSTEM DESIGNER N INFORMATON OBTAINED FROM MANUFACTURER DATASHEETS Peak Power Tracking Voltage 27V-37V CO LO 0 Operating Range 16V-48V Min./Max.Start Voltage 22V/48V Max DC Short Circuit Current 15A SHEET NAME Output Data(AC) WIRING Maximum Output Power 240W CALCULATIONS I ERMOCRATES CASTILLO PE# 52590 AN ENGINEER Nominal Output Current 1.0A LICENSED PURSUANT TO CHAPTER 471, CERTIFY SHEET SIZE Nominal Voltage/Range 240V/211-264V ANSI B THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL Nominal Frequency/Range Hz II " COMPONENTS ARE DESIGNED AND APPROVED USING �� X � THE STANDARDS CONTAINED IN THE MOST RECENT Extended FrequencyI Range 47-68 Hz VERSION OF THE FLORIDA BUILDING CODE. FBC 107. COPYRIGHTED BY CASTILLO Power Factor at rated power 1.0 SHEET NUMBER ENGINEERING SERVICES, LLC Maximum unit per 20A Branch Circuit 16(240 VAC) E-02 Castillo • • • • . . . . Engineering ELECTRIC SHOCK HAZARD • • • DESIGNED TO.fAMIT- DO NOT TOUCH TERMINALS • • CASTILLO ENGINEERING TERMINALS ON BOTH LINE AND • SERVICES,LLC LOAD SIDES MAY BE ENERGIZED LABEL LOCATION: 2925 W.STATE OAD 434, IN THE OPEN POSITION AC DISCONNECT,POINT OF INTERCONNECTION LABEL LOCATION: SUITE 111 LABEL LOCATION: (PER CODE:NEC690.54) AC DISCONNECT,DC DISCONNECT,POINT OF LONGWOOD,FL 32779 AC DISCONNECT,POINT OF INTERCONNECTION INTERCONNECTION TES.CAS"O-F PER CODE:NEC 690.17(E),CB • ' (PER CODE:NEC690.56(C)) ERnacluTESEVISIONS PEszsso REVISIONS • • OUTPUT • • . • • DESCRIPTION DATE REV LABEL LOCATION: LABEL LOCATION: POINT OF INTERCONNECTION CONDUIT,COMBINER BOX (PER CODE:NEC 705.12(D)(7)) I (PER CODE:NEC690.31(G)(3)(4)&NEC 690.13(G)(4) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] PROJECT INSTALLER LABEL LOCATION: DATA PER PANEL POINT OF INTERCONNECTION (PER CODE:NEC 705.12(D)(4)) [I]iIiLUS]J1 240 SU ADHESIVE FASTENED SIGNS: • • • 60 • . . •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. •• 240 •• i ' •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD �� I APPLIED LABELS,WARNINGS,AND MARKINGS SHOULD !`�' `� �I' { COMPLY WITH ANSI Z535.4[NEC 110.21(B)FIELD MARKING]. 1. LABEL LOCATION: ♦ >./•G•E • S�a •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF MAIN DISCONNECT PROPERLY ADHERED.VINYL SIGNS SHALL BE WEATHER • (PER CODE:NFPA 1 2015-11.12.2.1.5) N 52 5 9 0 RESISTANT[IFC 605.11.1.31 20 STATE F •:��U LABEL LOCATION: COMBINER BOX . (PER CODE:NEC690.52) , .. �••'��9�♦ ',' Q N��' - " �/fl tttt W U Cl) M z 0 J LL- -o WD Com 2 J O = 8 1 2c SHEET NAME SYSTEM LABELING SHEET SIZE ANSI B 11" X 17" COPYRIGHTED BY CASTILLO SHEET NUMBER ENGINEERING SERVICES, LLC E-03 - Engineer ng 1 DESIGNED TO PEI"IT• CASTILLO ENGINEERING SERVICES,LLC COAd 28345 2925 W.STATE ROAD 434, SUITE 111 LONGWOOD,FL 32779 LG N ON 2 _ TEL:i407)2�2575 ® 8 ERMOCRATES E.CASTLLO-FL PE 52590 erSA REVISIONS _ DESCRIFrnON DATE REV LG335N1C-VS a_ General Data Electrin( CeLPl pe6is(Mwiai(Type): Mormnlierkl N-type Mom . ..a ,�.1 vr calMJmr — ._...._ .:. .., .16 (WI 335 335W CeACanfiguatlan -- 6DCek(6X10) �h 341 USA ....._ ems�.,_Nuribarof.Bshaa Mod4e Dimarslaw(i.lcwxI 1,686mm n 1016-40 n 410 Mkight . 17.1 _983_ -___ 0.49 TeLGNeON2isLG'sbestsellingsolarmodule,andisoneofthemost UWARCoat4g a198 PROJECT INSTALLER powerful and versatile modules on the market today.Featuring LG's Cello '"u`e s¢(s u„e>lxrp a z►t.a.oe/000waa'.e ree s o3 90,.20t NI vs Technology,the LG NeON® 2 increases power output New updates ) ��"°�° include an extended performance warranty from 86% to 89.6% to Cbiee(Lh) 1000mm_20A Operatm CondJtions /Iwo give customers higher performance and reliability. 47i,Jr canecmr(Ifna�wrsl I L4/IA ���, �• -4o-sa CEO 20 D C®a �;r Certifications and fi : — SA00/113 [{6121St/-i-,22016,ffC 61730- ,�1� - 4,000!84 M -kxlAtl-DeYyr hadxShgFarskr(1.5) �� . Seal 1/?2(It 1 waPRc 4 UL 1703 CaUfinikarf 1509001,15Oi40o1,)5050001 PedIC0IWtiO,1 Vr7/"1) _ OHSAS1:212 T • •�•.• �' � Sd[NBstCultasioD"ks[ IEc 61701'20,2 6iwMftHQct, asu'_(L* � G.a M AmmDNaCprosiwrTet IEC 62716:2013 AandFarMlrla� 1,750• 1201 ModdeFirie ,mace Type i(M-1703) 4w N 2 590 Fie Radlq - ChesC PA79C ULC/0RDc 1703) - - 5d9ModlMP1odottwYar ty 25 Yeas �': '�' solve Modlk out9i* arrwlfy :.. liawrwama4y- Dimensions(mm/inch). •1)Fm ye 98%2)Aka i*yeee 035%amalderadar 3)89a%far 25 yeas' = ATE F 41J Tempereture Characteristics � Nhwr f-c1:: 42x3 __ �i ••E�T fl ••• t `�� matt IlIt1CT =0.36 ..• �?627 0.03 Iw:�ral „N Q',,���� •NMOT(NwrhiY ModMOpestagienpeaoaezkraiatmeoDWAN,AtrEhnctempewoee m•C t II wadspeed 1,efe,S .eAM 15 r.t r.r r Electrical N W Monti EG3351V C Ma4rurlPt_(Paw �.. 250. Cl) MPP rAW) ' ( 319 __ Z v! MPPCennl(knpp___(A Z" _.7.44 — 393 WW m LL Features 043 — W 0 Enhanced Performance Warranty 1 Enhanced Product Warranty (/) J J 25 I-V Curves U cn =I LG NeON®2 has an enhanced performance LG has extended the warranty of the NeON®2 o m a z. warranty.After 25 years,LG NeON®2 is guar- ----- to 25 years,which is among the top of industry tamw O Q anteed to perform at minimum 89.6%of initial standards. 10 0Lii Performance. — — — 60' M LUW pWf co Better Performance on a Sunny Day Roof Aesthetics °° LG NeON®2 now performs better on sunny LG NeON®2 has been designed with aesthetics in 20 zoaN C Gd days thanks to its improved temperature --- -- mind using thinner wires that appear all black at a So coefficient. distance.The LG NeON®2 can increase the aesthetic 00 10.0 200 300 400 value of your home with a more modem design. vbftw Iv) SHEET NAME MODULE About LG Electronics LGEI.Moeiswc R»dtawedRotlwwaesuhamdvin9ewltfoAnotim DATA SHEET IS Elsaoritswagirbal aadahrxLgricPoMcu in the deanawgynwkeo byoffe"soW PV perch and a 0ystorage opel*eThe90 tony foot ardakM atasdee-94wteraoa ¢a dtpran it 1985 Rapported byLG Stoop vox ererince M de sore-codoovo,LCD,dm maz mtry and aak kdories bm10.LG �V LG335N,C-VS_f6_11a01 5ahr ar�I IV rdsiW to first Maw( mries to the madeC 4,60090*available in 32 munnies The 14,050(prtrioas.MonoX°No0t4 Ne0Ne2,N,ao 2 LG 0201910 Ek[flmi[z/Wrigitsrnared wmtwadwlade,AWARD'M 2013,2015 and 2016,v.1echdenoo rates LG'oioodxshpad knototion MthesoWi any. ljfe'S Good telWzdre.A60069 SHEET SIZE ea aeaarlg-soiwenm ANSI B 11" X17" SHEET NUMBER DS-01 Castillo Engineering DESIGNED TO/IRMIT• CASTILLO ENGINEERING Data Sheet SERVICES,LLC Enphase Microinverters Enphase IQ 7 and IQ 7+ Microinverters �AT 2925 W.STATE ROAD 434, LONG WOOD FL 32779 Region:US INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US 2�'2576 ERMOCRATES E_CASnLLO-FL PE 52M Commonly used module pairings" 235W 350 W+ 235W 440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules REVISIONS Maximum input DC voltage 48 V DESCRIPTION DATE REV Peak power tracking voltage 27 V-37 V 27V-45V Operating range 16 V-48 V s � The high-powered smart grid-ready Min/Max start voltage 22V/48V 22V/60V Enphase Enphase IQ 7 Micro'"and Enphase IQ 7+Micro 1" Max Dc snort circuitcurrent(module isc) 15A Overvoltage class DC port li 11 �� 7dramatically simplify the installation process while and �Q 7+ DC port backfeed current OA 5.�� ' ,. " achieving the highest System efficiency. PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; Microinverters Part Of the En hase IQ System,the IQ 7 and AC side protection requires max 20A per branch circuit PROJECT INSTALLER Enphase OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter IQ 7+Microinverters integrate seamlessly with Peak output power 250VA 29SVft. " • " +.l TM n the Enphase IQ Envoy"',Enphase Q Aggregator 1", Maximum continuous output power 240 VA 290 VA Tw Nominal(L L)voltage/ranger 240 V! 208 V/ Enphase IQ Battery ,and the Enphase Enlighten 211-264V 18322 monitoring and analysis software. Maximum continuous output current 1.0A 1.15A 1.21 A 1.39 A Nominal frequency 60 Hz �� IQ Series Microinverters extend the reliability Extended frequency range 47-68 Hz 47-68 Hz re Signatu ,seal standards set forth by previous generations and AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A(L-L)branch circuity 16(240 VAC) 13(240 VAC) undergo over a million hours of power on testing, 13(208 VAC) 11(208 VAC) �'. enabling Enphase to provide an industry-leading overvoltage class AC port m III �. . w �.. •E•�SF••• �% warranty of up to 25 years. AC port backfeed current OA OA O 599 Power factor setting 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V — Peak CEC efficiency 97.6% 976% Easy to Install CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% a .4`. Lightweight and simple MECHANICAL DATA IQ 7 Microinverter M1 •• R •."r' Ambient temperature range` -40°C to+65°C • Faster Installation with improved,lighter two-wire cabling ��7 Relative humidity range 4%to 100%(condensing) 7fitT t I t 1 t!!! • Built-in rapid shutdown compliant(NEC 2014&2017) Connector type MC4(orArnphenol H4 UT . ._ i— Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) W C" It) Productive and Reliable Weight 1.08 kg(Z38Ibs) � ^pA � 4 rz O (n M Cooling Natural convection-No fans • Optimized for high powered 60-cell and 72-cell*modules Approved W J J for wet locations Yes; � -,� � W LL �a ; U • More than a million hours of testing Pollution degree PD3 • Class II double insulated enclosure Enclosure Class II double insulated," 1 ' C/) W_I J • UL listed Environmental category/UV exposure rating NEMA Type 6/outdoor W m - FEATURES W O II Communication Power Line Communicatl _ ate. �„ Smart Grid Ready p W U >- Monitoring Enlighten Manager and MyEnlighten monitoring options. J _ • Complies with advanced grid support,voltage and Both options require installation of an Enphase IQ Envoy. 0•, frequency ride-through requirements Disconnecting means The AC and DC connector M W disconnect required by N JCO• Remotely updates to respond to changing N Compliance CA Rule 21(UL 1741-SA) grid requirements UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B, • Configurable for varying grid profiles CAN/CSA-C22.2 NO.107.1-01 • Meets CA Rule 21(UL 1741-SA) This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC SHEET NAME and DC conductors,when installed according manufacturer's Instructions. U� *The 107+Micro is required to support 72-cell modules. INVERTER 1.No enforced DC/AC ratio.See the compatibility calculator at httpsJ/enohase.coin/en-us/support/module-compatlbllnv: 2.Nominal voltage range can be extended beyond nominal if required by the utility. DATA SHEET 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. EN PHASE E. To learn more about Enphase offerings,visit enphase.com SHEET SIZE To learn more about Enphase offerings,visit enphase.com v E N P HAS E, O 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. AN S 2018-02-08 11" X 17" SHEET NUMBER DS-02 Castillo C3 Engineering DESIGNED TO PIRMIT• CASTILLO ENGINEERING SERVICES,LLC COA#28345 Data Sheet Enphase IQ Combiner 3 2925 W. EE OAD 434, Enphase Networking M NUMBER LONcwUID,FL 32779 ODEL _ 7EL:t4DT)289-2575 IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase l ERMOCRATES E.CASTRLO-FL PE 52590 production metering(ANSI C � 'z REVISIONS ACCESSORIES and REPLACEMENT PARTS(not included,order separately) DESCRIPTION DATE REV Enphase Mobile Connect" h + IR , CELLMODEM-03(4G/12-year data plan) Plug and play Industrial grade CELLMODEM 01(3G/5-year data plan) microinverters.(Available in CELLMODEM-M1(4G based LTE-M/5-year data plan) where there is adequate cello tT Enphase The Enphase IQ Combiner 3'"with Enphase Consumption Monitoring"CT CT-200-SPLIT Split core current transformers enable whole home consumption metering(+/ 2.5%) IQ Envoy consolidates interconnection ' IQ Combiner 3 Circuit Breakers 5vppottsEa#onBR21QBR21 �, equipment into a single enclosure and BRK-10A 2-240 Circuit breaker,2 pole,IOA,E BRK-15A 2 240 Circuit breaker,2 pole,l5A Ei) r � � d � ���,�� � �"r�� (X-I AM1 24�-3� 9 y BRK-20A-2P-240 Circuit breaker,2 pole,20A,E � : Q- streamlines PV and storage installations b �v. •�� - - PROJECT INSTALLER EPLC-01 Power line carrier(communication bridge pair),quantity 2 providing a consistent,pre-wired Solution for XA-PLUG-120-3 Accessory receptacle forP-owerL ��� circuit SUNP1 residential applications. It offers up to four XA-ENV-PCBA-3 Replacement lQ Envoy printed circuitboard(PCB)forCombiner3 • ELECTRICAL SPECIFICATIONS 2-pole input circuits and Eaton BR series Rating Continuous duty busbar assembly. System voltage 120/240 VAC,60 Hz r " _ Eaton BR series busbar rating 125 A ♦♦♦ C /•• Max.continuous current rating(output to grid) 65 A E/i' •. O " Max.fuse/circuit rating(output) 90 A •�' Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not Included) Max.continuous current rating(input from PV) 64 A Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included — Smart Production Metering tT � ', 200A solid core pre-installed and wlIe4 10 Iti Env �° �,�� �. :�:. 4 0 A E 0 • Includes IQ Envoy for communication MECHANICAL DATA and control .n,. ._ -.. Dimensions(WXHXO) 49.5 x 37.5 x=16;Scm(19 8 x) E T • • Flexible networking supports Wi-Fi, i ' / •�C?♦♦ Ethernet,or cellular Weight 7.5 kg(16.5Ibs) X77 N• ••`G `�♦♦ Ambienttemperaturerange -40°Cto+46°C(-40°to 115° a� �s �71111IIl it1♦ Optional AC receptacle available for PLC .,, i bridge Cooling Natural convection,plus heat shield e e • Provides production metering and optional Enclosure environmental rating Outdoor,HITT:-certified,NEM ti consumption monitoring ` Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors W ('4) • 60 A breaker branch input:4 to 1/0 AWG copper conductors (.) M • Main lug combined output: 10 to 2/0 AWG copper conductors — Simple • Neutral and ground: 14 to 1/0 copper conductors Z J L j Always follow local code requirements for conductor sizing O m .w ,, � O a • Reduced size from previous combiner Altitude To 2ti00meters,(6,56Qfeet) W J • Centered mounting brackets support single INTERNET CONNECTION OPTIONS W J J_ stud mounting _„ Integrated Wi+i 802.11b/g/n c n m Z • Supports back and side conduit entry W Q Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) W U } • Up to four 2-pole branch circuits for 240 VAC Cellular Optional CEt LMODEM 01(3 - t W N. plug-in breakers(not included) (not included) , • 80 A total PV or storage branch circuits COMPLIANCE m W Compliance, UL 1741 Reliable CAN/CSAC22.2 No 107.1' 47 CFR,Part 15,Class B,ICES + Q�1 Production metering:ANSI Cl• TMfe 6 Durable NRTL-certified NEMA type Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 3R enclosure t H T NAME ti \ • Five-year warranty *Consumption monitoring is required for Enphase Storage Systems. CbM BIN ER BOX ®L UL listed DATA SHEET LISTED To learn more about Enphase offerings,visit enphase.com a'2018 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner j E N P H AS E. SHEET SIZE To learn more about Enphase offerings,visit enpfiase.corn v 2018-09-13 V ANSI B 11" X17" SHEET NUMBER DS-03 •Cas tillo Engineering 0 E:5IGNEO TO■EIMIT• CASTILLO ENGINEERING • • . •••• • SERVICES,LLC U N I RAC ��• • k U N I RA • i • •• 2925 W.STATE ROAD 434, A HILTI GROUP COMPANY A HILT]GROUP COMPANY SUITE 111 LONG WOOD,FL 32779 TEL:(407)299-2575 SolarMount Mid Clamp ERMOCRATES E.CAST91C-FL PE 52599 Part No.320008,320009,320019,320020,320021, REVISIONS 320084 320085,320086,320087,320120,320122 SolarMount Technical Datasheet • Mid clam material:One of theDESCRIPTION DATE REv Mid Pub 100602-ltd V1.0 June 2010 Bolt pfollowing extruded aluminum alloys:6005-T5,6105-T5,6061-T6 Clamp la Ultimate tensile:38ksi,Yield:35 ksi SolarMount Module Connection Hardware.................................................................. 1 Finish:Clear or Dark Anodized Bottom Up Module Clip.................................................................................................1 Mid clamp weight:0.050 lbs(23g) Mid Clamp u • Allowable and design loads are valid when components are ... ..........................................................................................2 assembled according to authonzed UNIRAC documents End Clamp ..... ......... 2 • Values represent the allowable and design SolarMount Beam Connection Hardware......................................................................3 load capacity single ` mid damp assembly when used with a SolarMount series beam to L-Foot...........................................................................................................................3 retain a module in the direction indicated PROJECT INSTALLER SolarMount Beams......... ............................................................................................4 • Assemble mid damp with one Unirac'/47-20 T bolt and one'/.'-20 ASTM F594 serrated tighten nut . � • Use anti-seize and totighten 10 ft-ibs of torque am • Resistance factors and safety factors are determined according to { part 1 section 9 of the 2005 Aluminum Design Manual and third- 11111. e z party test results from an PAS accredited laboratory >.aoolsurl� Applied Load Average Allowable -- Direction Safety Design Resistance SF•'•, SolarMount Module Connection Hardware BE,,,,,®I,�,,,� Ul imate Load Factor, Load Factor, O 525 0 Ti Tension,Y+ 2020(8987) 891(3963) 227 1348(5994) 0.667 SolarMount Bottom Up Module Clip 1 Transverse,& 520(2313) 229(1017) 227 346(1539) 0.665 . Part No.321001,321002 Y Sliding,Xt 1194(5312) 490(2179) 2.44 741(3295) 0.620 • A E O Bottom Up Clip material:One of the following extruded aluminum 'x •'•4 R •• Bottom alloys:6005-T5,6105-T5,6061-T6 Dimensions specified in inches unless noted Up Ultimate tensile:38ksi,Yield:35 ksi SolarMounta t ttt` • Finish:Clear Anodized SlM t End Clamp sh u • Bottom Up Clip weight:-4.031 Its(14g) Part No.320002,320003,320004,320005,320006, 320012,320013,320014,320015,320016,320017, Beam BoK • Allowable and design loads are valid when components are 320079,320080,320081,320082,320083,320117, assembled with SolarMount series beams according to authorized 320118,320123,320124,320173 320185,320220, • End Clamp material:One of the following extruded aluminum j UNIRAC documents 320233,320234,320331 alloys:6005-T5,6105-T5,6061-T6 • Assemble with one'/,"-20 ASTM F593 bolt,one W-20 ASTM F594 F•r • Ultimate tensile:38ksi,Yield:35 ksi W M serrated flange nut,and one 1/4"flat washer • Finish:Clear or Dark Anodized U C•) • Use anti-seize and tighten to 10 ft-lbs of torque • End clamp weight:varies based on height:-0.058 lbs(26g) Z • LL.Resistance factors and safety factors are determined according to #N is Wd Clamp • Allowable and design loads are valid when components are W m part 1 section 9 of the 2005 Aluminum Design Manual and third- is assembled according to authorized UNIRAC documents W Vj party test results from an PAS accredited laboratory ) q�� i • Values represent the allowable and design load capacity of a single Cl) J • Module edge must be fully supported by the beam end damp assembly when used with a SolarMount series beam to m _ * NOTE ON WASHER:Install washer on bolt head side of assembly. _ retain a module in the direction indicated O I DO NOT install washer under serrated flange nut • Assemble with one Unirac%'-20 T-bolt and one W-20 ASTM F594 W V } ea serrated flange nut J = Applied Load Average Allowable Safety Design Resistance • Use anti-seize and tighten to 10 ft Ib8 of torque • Resistance factors and safety factors are determined according to M W Direction Ultimate Load FactF Load Factor, part 1 section 9 of the 2005 Aluminum Design Manual and thirdN - Ibs(N) lbs(N) FS lbs(N) m Y 124 Tension,Y+ 1566 6967 686 3052 2,28 1038 4615 0.662 • party test results from an LAS acctedited laboratory ( ) ( ) ( ) Modules must be installed at least 1.5 in from either end of a beam q LOO Transverse,Xi 1128(5019) 329(1463) 3.43 497(2213) 0.441 ► (.+ im Applied X Load Average Allowable Safety Design Resistance Sliding,Zt 66(292) 27(119) 2.44 41(181) 0.619 NI OKM- SHEET NAME Direction Unkyu" f Factor, Loads Faeroe; RAIL Hoarr Dimensions specified In Indies unless noted Tension.Y+ 1321(5876) 529(2352) 2.50 800(3657) 0.605 DATA SHEET 71° Transverse,It 63(279) 14(61) 4.58 21(92) 0.330 Sliding,Xi 142(630) 52(231) 2.72 79(349) 0.555 SHEET SIZE Dimensions specified in tithes unless noted ANSI B ® 1111X17" SHEET NUMBER DS-04 • Engineering DEi16NED TO pIIT. RAC® CASTILLO S,LLC ENGINEERING FLASHKIT '. 2925 W-SUITETROAD 434. PROT .. NIRAC LN o GWOOD F1.32779 .. NI . { FEATURING 0 SHED G,SEAL TECHNOLOGY 0 ERraocwrr SE40c snLLO'�a�szseo INSTALLATION GUIDE FEATURING SPIED G.SEAL TECHNOLOGY REVISIONS FLASHKIT PRO is the complete attachment solution for composition shingle roofs. Featuring Unirac's patented DESCRIPTION DATE REV FLASHKIT PRO IS THE COMPLETE FLASHING AND ATTACHMENT SOLUTION FOR SHED & SEAL technology, a weather proof system which provides the ultimate protection against roof leaks. COMPOSITION ROOFS. Kilted in 10 packs for maximum convenience, flashings and hardware are available in Mill or Dark finishes. With FLASHKIT pro,you have everything you need for a quick,professional installation. PROJECT INSTALLER INSTALL FLASHKIT PRO FLASHING INSTALL L-FOOT ATTACH LF00TT0 RAIL S U N P I PPP PRE-INSTALL •Drive the lag bolt down until the 1-foot is held firmly in place. It is normal for the EPDM on the underside of the stainless steel backed .`� N s� • O ' •Locate roof rafters and snap chalk lines to mark the installation EPDM washer to compress and expand beyond the outside edge of . •.•. point for each roof attachment. the steel washer when the proper torque is applied. 0 52590 •Drill a 1/32"pilot hole at each roof attachment.Fill each pilot hole P: S with sealant. TI •Use iontoavoKl ov ADrqueingthelagboltifusingan irrpactdriver. • S ATE F STEP 1 INSTALL FLASHKIT PRO FLASHING -Repeat Steps 1 and 2 at each roof attachment point. '• ? ' •Add a U-shaped bead of roof sealant to the underside of the flashing with the open side of the U pointing down the roof slope.Slide STEP 3 ATTACH L-FOOT , TO RAIL the aluminum flashing underneath the row of shingles directly up •Insert the included 3/8"-16 T-bolts into the lower slot on the Rail slope from the pilot hole as shown.Align the indicator marks on the (sold separately),spacing the bolts to match the spacing between lower end of the flashing with the chalk lines on the roof to center the roof attachments. LO the raised hole in the flashing over the pilot hole in the roof.When U to M installed correctly,the flashing will extend under the two courses of •Position the Rail against the L-Foot and insert the threaded end of Z shingles above the pilot hole theT-Bolt through the continuous slot in the L-Foot Apply anti-seize to bolt threads to prevent galling of the 1-bolt and included 3/8" W �► serrated flange nut Place the 3/8"flange nut on the 1-bolt and Fa STEP 2 INSTALL[-FOOT finger tighten.Repeat STEP 3 until all 1-Feet are secured to the Rail IX m with a T-bolt Adjust the level and height of the Rail and torque each W O D •Fasten L- boltth 3011 1bs foot and Flashing into place by passing the included lag J S bolt and pre installed stainless steel backed EPDM washer through N.TRUSTED WATER SEAL FLASHINGS YOUR COMPLETE SOLUTION CONVENIENT 10 PACKS the L-foot EPDM grommet,and the raised hole in the flashing,into r~) w FEATURING 0 SHED&SEAL.TECHNOLOGY Hashirgs,bps,continuous sslot 1-Feet and hardware Packaged for speed and ease of handling the pilot hole in the roof rafter. m N SHEET NAME COMPLETE SOLUTION FASTER INSTALLATION. WARRANTY, ATTACHMENT DATA SHEET SHEET SIZE 1 1 / ' 1 R 1 I 1 / 1 R ANSI B 11"X 17" SHEET NUMBER DS-05