Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-22611
CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020 22611 ELECTRICAL PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit#:22611 Issued: 3/20/2020 Address: 5904 9TH ST Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 35,806.00 Total Fees: 390.00 Subdivision: CITY OF ZEPHYRHILLS Amount Paid: 390.00 Date Paid: 3/20/2020 Parcel Number: 11-26-21-0010-01500-0150 CONTRACTOR INFORMATION OWNER INFORMATION Name: SOLAR BEAR LLC Name: DELROY, THOMAS Addr: 6101 JOHNS RD STE 8 Address: 5904 9TH ST TAMPA, FL 33634 ZEPHYRHILLS, FL. 33542 Phone: (727)235-8519 Lic: Phone: 305-363-8960 Work Desc: INSTALL ROOF MOUNT SOLAR W/ELECTRIC PANEL UPGRADE 200 AMPS APPLICATION FEES ELECTRICAL FEE 322.50 BUILDING FEE 67.50 ROUGH ELECTRIC INSPECTIONS REQUIRED CONSTRUCTI( W POLE FEE-METER V FINAL REINSPECTION FEES:(c)With respect to Reinspection fees will comply-with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. ;�7 �f.CfJ� ONTRACTOR PER OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received 2� �Z rrrrrr Phone Contact for Permitting 727 940,3256 -ITrI Owner's Name THOMAS DELROY A Owner Phone Number 3053638960 Owner's Address 1 5904 9TH STREET,ZEPHYRHILLS,FL 33542 Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 5904 9TH STREET,ZEPHYRH ILLS,FL 33542 LOT# 15&16 SUBDIVISION CITY OF ZEPHYRHILLS PARCEL ID# 11-26-21-0010-01500-0150 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR B ADD/ALT � SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK INSTALL ROOF MOUNTED SOLAR PV SYSTEM. 8.37KW BUILDING SIZE I SO FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ 34,306 AMP SERVICE = PROGRESS ENERGY Q W.R.EJ.C. =PLUMBING $ (/ �� =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION O L �(/'�•3 �oG =GAS = ROOFING = SPECIALTY = OTHER= \ FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA YES NO ( !W!/ 1Rr�uc/ryI� BUILDER r- �A -ti COMPANY , ems_ SIGNATUREREGISTERED I Y/ N FEE cuRRen Y/N Address License# ELECTRICIANS r' P 'L '1 ti It O OLAR BEAR MPANY S LLC SIGNATURE `r �- s� REGISTERED N FEE CURREK Y/N Address 6101 JOHNS RD STE B TAMPA FL 33634 1 License# 1 EC13009020 PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURREN I Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREA I Y/N Address License# IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII11111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal dale. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal dale. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) •• Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW CITY OF " NOTICE / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE , ADDRESS DATE PERMIT THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the lob will be accepted. co I, LftY- r-�, S ra,, � It is unlawful.for any Ca nter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR �l G, --- I �f ll �j V4 ��' 2-2--� jj r �,�� � . i �� NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the'owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and.sworn-to,(or-affirmed)before•me this by by Who is/are personally known to me or hasihave produced Who is/are personally known to me or hasihave produced DL as identification. DL as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 727 940.3256 ->—ITr17--rr Owner's Name THOMAS DELROY A Owner Phone Number 3053638960 Owner's Address 1 5904 9TH STREET,ZEPHYRHILLS,FL 33542 Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 5904 9TH STREET,ZEPHYRHILLS,FL 33542 LOT# 15&16 SUBDIVISION CITY OF ZEPHYRHILLS I PARCEL ID# 1 1-26-21-001 0-01 500-01 50 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT Q SIGN 0 0 DEMOLISH INSTALL REPAIR PROPOSED USE Q SFR Q COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK SERVICE PANEL UPGRADE TO 200 AMPS BUILDING SIZE SO FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION ©ELECTRICAL $ 1500 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREK Y/N Address License# ELECTRICIAN COMPANY SOLAR BEAR LLC SIGNATURE REGISTERED &V N FEE CURREK Address 6101 JOHNS RD STE B TAMiPA FL 33634 License# EC13009020 PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREK Y/N Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREK Y/N Address I License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREK Y/N Address License# Illlllllllllltlllllllllllllllllllillllllllllllllllllltlllllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs 9 shingles Sewers Service Upgrades A/C Fences(PIDt/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy'or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner',I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,Cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by by Who is/are personally known to me or hasihave produced Who is/are personally known to me or hasthave produced DL as identification. DL as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped INSTR#2020032863 OR BK 10059 PG61 P,g,l .fl 02125/2020 02:44 PM Rcpt:2138796 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq., Pasco County Clerk&Comptroller PREPARED BY:SOLAR BEAR LLC 6101 JOHNS RD STE B TAMPA FL 33634 perml 1-1-26-*21-0'010'-01509-OFTSO-' NOTICE OF COMMENCEMENT Stale of Florida Co;inly of PASCO THE UNDERSIGNED hem.4 gives N�w Mal kWwmgM va be made to cg4ah Mal VWM,and in=Kunos wgh Sectim 71113 of Me Florida St3h&&ft WDW V h'wwbm is vvAled In fts NOTICE OF COMMENCEMENT. llbeso#don of pro"(kg33 descqt[off): CITY OF ZEPHYRHILLS PB 1 PG 54 LOTS 15&16 BLOCK 15 "it SL at Uobw- sSi'_ 51aq. .ql In. tGcnic�I resat` INSTAU Sot.AiAi SYsYf-:M D*cq -1�0#A5 5104 C)wetwiftPMPwy. 100.%.- 4.1001ttractorwornlation ".. a)Nara ard addr= NORMAN PURKV.SOUR 13An UC-6101 JOHNS Flo STE 8 TAMPA FL 23&U ..� I % b)'tel0phooeNoz 7271-440.3256 Fax No-,(opftial Lswety(d 4 ow ue.a c oiy if vi iaya:.ent 6wd iam ih 0) a)Name w4 akt= WA ff b)Tewm No_ a)Team Waddress: JY=A ------ b)TabOmNo.: 713.13 11)(a)7,Paida SWL= a)XWW and addressFUA b); NW FaxVw(WWA x UJ of 1AJ <to receive g copycopyof co Wres Nace as provkted in Sechm 713.13(1)(b),Floridar. Z 0 SbW — U) 0 0 (n Lu u- u- 0 F- 9.ExpM=data of D1000 dccjm==e=id Ift expiration date may W be before ft woellmd=WUOM arld tw parxmt to Ina oz =C-) (n -J Q — — < btilw3bed hm the date d moor&V wires a differentdale 1sqwffi4., 20 U) 0 0 U., 0 w WARNING TO=M-ANY PA-Y`M Ek S'jtAbE BY THE OM6UFTilt TIfE eXPMTM CO OF THE NOTICE OF UE-K-=E-R-T-ARE 0. w CQX=EM LvROpER M pAygE UNDER CHAPTER 7113,PART L SECTION TW3,FLORIDA STATUTES,AND &L = P 40 TVXE FOR ggM AND CAN RESULT IN YOUR Er < pREM TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON ON 0 LL AYL ui THE JOB SITE BEFORE IM FIRST INSPECTION.IF YOU INTEND TO OBTA24 FINANCING,CONSULT WITH YOUR LENDER OR AN It WT 0 U AMMODEFOR COMMENCING WORXOR RECORDING YOUR NOTICE OFCONMENCEMENT. C-) E z 0 C Urglarlm,ally WpijM'l diolim-lit hiim mad the WeVM WIW*Aiimei>cemeritikidkkii 6c13 0 CL x Lut twwt 7d a rx!b 0&r")— -) 0 z U, U- V*Q Ld =3 z 0 w a- < >-- 0 u 6 L_j dayof Uj 0 0 >- ry 0 0 for x ,_; 1 200u) > J6 Z U.1 CnJ U 3 < _J — LU T-1J z TrA Cd ID OL Cr z 0 z pamm EWMARIN WCOMM #00 314344 UM 161archI9,20n TIMUNDWY DIRECTORY OF PAGES ,�;� SCOPE OF WORK P-133173 PV-1 PROJECTSUMMARY Q e THIS PROJECT INVOLVES THE INSTALLATION OF A PV-2 SINGLE-LINE DIAGRAM �y�t`Pv PHOTOVOLTAIC POWER SYSTEM,SOLAR PANELS WILL BE RACKED USING A PR ENGIN ERED RACKING SYSTEM.THE PV-3 SAFETY LABELS - J'� RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH O DC TO AC POWER INVERTERS AND INTERCONNECTED TO THEMODULE DATASHEET Si OPTIMIZER D TASHEET 1 WITH THE RULES ENFORCED BY THE LOCLOCAL UTILITY USING MEANSAND ADS�ON YAND STENT P A A X _ PERMITTING JURISDICTION. z ASH DISCONNECT DATEET ' a INVERTER OAT SHEET ♦ THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF W W IL ? DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH MOUNTING SYSTEM ENGINEERING LETTER ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH U APPLICABLE CODES AND REGULATIONS.THE DOCUMENT U) Z CV UL27IXi GROUND AND BONDING CERTIFICATION Pie SHALL NOT BE RELIED UPON ASA SUBSTITUTE FOR >- ys FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. C/) 0 LL THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS COPROJECT DETAILS USTING AND INSTALLATION INSTRUCTIONS,AS WELL AS ALL CA CM APPUCABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE W LLJ F- J PROPERTY OWNER DELROY THOMAS INTERPRETED IN A WAY THAT OVERRIDES THEM. � w U) I.1_- 59049TH ST,ZEPHYRH ILLS,FL33542 ,o CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL PROPERTY ADDRESS US a CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT. d ¢ U) ZONING RESIDENTIAL - r , W J USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING ^a hap dot.02M SYSTEM DETAILS p rn CLASSIFICATION GROUP(GROUP R3) NEWGRID-INTERACTIVE 1 PLOT DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO O ~ Lo >- UTILITY COMPANY PROGRESS ENERGY FLORIDA INC U)PV-1 SCALE:TUTS BATTERY STORAGE } _ ELECTRICAL CODE 2014 NEC(NFPA 70) _ __ DC RATING OF SYSTEM 8,370W O FIRE CODE 2015 NFPA 1 AC RATING OF SYSTEM 7,600W N LU OTHER BUILDING Q - - '""T- as - I c W CODES 2017 FL BUILDING CODEIrv'' AC OUTPUT CURRENT 32.OA Q . Richland; INVERTER(S) 1 X SOLAR EDGE SE7600H-US I , CONTRACTOR INFORMATION _. �,cy - - !' MODULE JBIL'FABSlA310M COMPANYBAY AREA PROJECT SOLUTIONS "' "- '' � ARRAY WIRING ING OF I3- ING OF 14 2512 BAY FIELD CT,HOLIDAY,FL ADDRESS 34691 INTERCONNECTION DETAILS PHONE NUMBER Q27)543b361 �- _ � Rcd North r' "® NEW SUPPLY SIDE AC CONNECTION POINT OF CONNECTION PER NEC705.12(A) �Ze Westills'"Zeph rhdls .4Hi'Upper'."•"TI4�'�"',,,,'_r�,- ,e-3 UTILITY SERVICE 120/240V 1� _ f sboio""ugh L - .3 Q"i SkydlvedCity%Z=Hiils,®`^ Pies'erv."e rJ SITE DETAILS 70pfry41lll0 South ASHRAE EXTREME LOW 1°C(34°F) o\ ASHRAE 2%HIGH 34°C(93°F) ® I jN.-r' ® "-I CLIMATE DATA SOURCE ST.PETERSBURG CLEAR(KSPG) PROJECT Map data WIND SPEED 160MPH(ASCE7-10) SUMMARY _,__ �21LOCALE RISK CATEGORY II DOC ID:133173-165361-1 WIND EXPOSURE C DATE:2/25120 PV-1 SCALE:NTS CATEGORY CREATOR: REVIEWER: REVISIONS PV-1 JPM MODULE MODULES GENERAL ELECTRICAL NOTES P-133173 I I OPTIMIZER / REF. GTr. MAXEANDMODE. PMAX FTC ISC IMP vW VMP TEMP.006F.aFVW FUSERNTNc UTILITY HAS24HRUNRESTRICTEDACCESSTOALL I I MMt-a n sILFABswIBM 310N ze7w esx B33A Now Saw alzrvrc(a3+srq 75q 1 PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE PM1.27 INVERTERS SERVICE ENTRANCE. I I 31OW �� REF T'7 MAXEANOMODEL AC VOLTAGE GRWND MAX OCPD RATIND RATED POT— MA%OUiPUTWRRENT MAXINRNTCIIRRENT MAXINPUTVWTAGE CECWEGHTEDEFROENCY n + saaREDEEsvmMTus z4w uNrnWnDED 40A 7,60AN 320A z°w 480v eBDBB 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 3. 114W 1131N QQ % (STRING ISiRINC POWER OPTIMIZERS CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS I I REF. QTY. MODEL RATEDINPUTPONER MAXOUTPUTCURRFNi MAXINPUTISC MAXCCVOLTAGE WEIGHT®EFFICIENCY 3 SUNLIGHT RESISTANT PER NEC ARTICLE300.6(C)(1)AND BAY VAR IA PGI-z7 n SDw4EDGEP320 32oW 15A n.a - — ARTICLE 310.8(D). A I I PASS-THRU BOXES AND COMBINERS CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE r-- REF DIY. MAKE ANDMWE. RATED CURRENT MAXRATEOVOLTPGE ( BI (ENERL(EIIAW&T XOREOIry 30A 2awncNOmuoc 4 SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE j 1 DISCONNECTS OCPDS 310.8(C). �JUNCTIONBOX �. MAXEANDMODE RATEDCURRENT MRATEDVOLTAGE REF. OIY RATED CIIRRE4i MAXVWTAGE W SWI 1 EATCNDGRdNR EOJIV 6oA 2dwPD F1-] 2 d0A 24P/AC W GROUNDING NOTES H r— RIYSTEMSUMIMARYYSTEM SUMMARY NOTES N UzSTWNGI STRINGz I ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE � Z C;I- OCPIIABZHtSPROJIDERAROSHUTOQYNFUWTONAUTYREWIP£OBYNt�fi9012 1REQUIREMENTS OF NEC ARTICLES 2508690 WNVERTERW�If WRREM IS4 154 �,(� ERIEs ORPl4DTHESEOPIIVJffRSHAVEANINPUT TA(EW)PID NDEEi01X#ITO PVMODULESSHALLBEGROUNDEDTOMOUNTINGRAILS � cl MwLTecE pCµy TE1NEg11y TA ERANGEO TKEMCOULEATTHEOESIMTEl1PERATMS VEAMAXINMTWRRMTRAVI THATISABWETNEW USING MODULE LUGS OR RACKING INTEGRATED W (nNGCURRBNT W F—ER B.37w4 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. u� WACC 71� UNGRWNDmSY51ENDCCMDWTd SHALLBEMMIX MOMFIXLOWSOCPOSITNESIWLBEREO(ORMAW(EOREO)ANDDCNEGOTIVESH LBEBINX ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED c _ cd OUTNF7 7.WUV oR MaxED BLa x) USING UL-LISTED LAY-IN LUGS. N F-- jJERgRPJf 7,575W AILMETALENWOSUREAS,RACEWAYS,CABLESANDEPOSEDNONWRRENTCMR NOWTALPARTSOFEQUPMENTSH SEMWNDEDTOEPATHASRMUR® INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS ofrn J_ I �WNEC2504(B)ANDPARTIIIOFNECARIICIE] MDEWIRAENTGRWNDINGWINOUCTORSSIWLBESIMACCOROINGTONE M45THEGRWNDING 3 BEEN EVALUATED FOR COMPLIANCE WITH UL2703 O = I E.ECTRWESYSH SW MHERE7OM47(8)AND25alM.THEWGRWNOIWaEC .ESHALLBESI7E0ACCORDINGT025D1M I 'GROUNDING AND BONDING'WHEN USED WITH PROPOSED O = rn ll� 4 ANADDIRONN.ARRAY GROUNDING ELECTRODE SHALL.BE INSTALLED IN ACCORDANCE NTH NEC SECTIONS 25D52AND 25054 UNLESS THEARRAY STRUCTURE IS PV MODULE. C/3 F— � �- --- ®SUITABLETOSERVEASAGRWNDING EIECTRODEAS PERNEC SECTION 2502,THELOADSERVED BYTHEAAAAY IS INTEGRALWTH THEARRAY.DRTHEPREMISEs ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED I 1-2 PVSYSTEM EMSTINGWIRINGaZITROOE IS LOCATED NMTHIN BET,AS PEANECSECTIONM47(0) 4 m /� L--- A DISCONNECT FOR THEIR PURPOSE W O W T. SW7 M%XDCVO.TAGEOF Y FRED BY THE INVERTER AT 4WV REGARDLESS OF TENPERATURE THE MAXDCVOLTAGSOF THE MODULEAT I-C IS E)MTED TO BE �11`THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE I-- w IV BOA 432V(I•C-VC)Xd.I2IVC-4)25V-432V) 5 VERIFIABLE GROUNDING ELECTRODE,IT IS THE pp L 1 5 QWSYSTEMDISCONNECTSHALLBEAMSIBIEKWFEBLADE TYPE DISCONNECTTHATISACCESSIBtE"LCCKAHEBYMEIRIUTY THE DISCCNE SHALL CONTRACTOR'SUNDINGELECTRODE,IY TO TISTH I (200AMSPWQwAMCB) LOCATED WHHIN IOFTOF UTILITY MElE0. ALL A LE-, m ® a , SR YsmEOFSDMCEDISWNWT,A7ALar�4LYnPmG®WNNEcnoFaNr.usNCLDcuLYnPrnwEDMEInAND SUPPLEMENTAL GROUNDING ELECTRODE. HMARFINCD.RWCEWTHNEC012! AC SYSTEM GROUNDING ELECTRODE CON DUCTOR(GEC) Loans 6 SHALL BE A MINIMUM SIZE#8AWG WHEN INSULATED,#6AWG CONDUCTOR AND CONDUIT SCHEDULE W7ELECTRICAL CALCULATIONS IF BARE WIRE. t WRREnTrA Wnnc ® �EQUIIPMENT GROUNDING CONDUCTORS SHALL BE SIZED CONDATI TEMP CORR FILL CONT. MA%WRRENT EASE BERATED TERM AMP TERM Qj 1YflCN. CONDUCTOR LONOUCIORS IN WNOAi/ OCPo EX CABLE CABLE FACTOR FACTOR CURRENT (1a) AMP. AHP. TEMP.RATING TEMP.RATNO ACCORDING TO NEC ARTICLE 690.45,AND BEA MINIMUM OF 2JTUTY401120 10,3W I I +O AWGPV WIRE. FREENR WA WA BANGBARE,COPPER 07115BC) 10 15A 187M 5SA mm 75'C 5M 7 , V Ac �"MR z4wt20v IQ,3w WPPER #tOAWG WHEN NOT EXPOSED TO DAMAGE,AND#6AWG DEC 2 1 HIA�1�Z 075 DIA VNC 4 NIA 10A�2 071(WC) 08 15A IB75A aDA 2272A DO'c NBA SHALL BE USED WHEN EXPOSED TO DAMAGE ll)l W WRF, JGROUNDING AND BONDING CONDUCTORS,IF INSULATED, 3 1 COWER FREENR WA WA BANG BAAE,fAPPEA D711scc) to 15a Ie7sA 55A 39 BSA 7sro 5°^ 8 SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF I)I B PWGIMNN2 1DANG IHYYN-2 4 1 05'DA LFNC 2 WA ow(N-C) 10 32A 404 SSA Sim 75-C 5O4 WPPER COPPER #AMONG OR LARGER 5 1 COPPER 2' 05'DALFNC 2 40AX2 -2' 0..00(34-C) 1.0 32A 40A 55A 52&A 75-C 50A ���llllllllll��' SINGLE-LINE DIAGRAM PROJECT ID:133173 DATE: 0225120 CREATED BY: SDT CHECKED BY: REVISIONS SINGLE-LINE DIAGRAM PV-2 SCALE: NTS •A� TIOpLO.YMSWWMENTHASBEENWEATEDFO MEWMMOFME IONGRENSONOFAR1OPo MOMOLTNCPONER5Y5TEMMMENOUWDTNLTOMMONS lCWAIM'M MNLAPRICABLECOOE9ANOREGUATIONSTNEMMMENTSHMMNWSEMMUMNASASII&ST MFOR �" FOMWACNRERNST,WATIONMINUAI51N5TADERUM WSTALLNLEOJIPA£NTINA¢010AN¢IMiHIMNUF MRINSTADATMAWNOALSNONINGINTHI5000UMENTMMWBEINTENAETEDINAWAYMATOYERNOESMEINSTRUCYIONSMMUFACNPEFWSTNIATMN UNS, V L EACH CE E ENERGIZED, DC RACEWAYS O SEE NOTE N0.4(DC RACEWAYS) O POINT-OF-INTERCONNECTION OR AT MAIN O UNGROUNDED CIRCUITS UITS MAY EXPOSED LABELING NOTES P-133173 OSERMCEOISCONNECT(MSP) DURING SERVICE.(JB1,11) 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC 1 - I AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. LABELS,WARNING(S)AND MARKING SHALL COMPLY �Jjk JB1-TRANSITION BOX POWERITO TiHS BUILDIN.G'1111, O�FRO_M.ROOF I©6 OG T _D WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, (MODEL NOT SPECIFIED PHOTOVOLTAIC••� MOUNTED�SOIAR'ARRAYWITH SAFETY CO 'Tt7R O -AI AS HEADER WARNINGCO ORS,HEADER AND CAUTION GTEXT,AND SAFETY ANS USED THE LERTARD DISCONNECTSAS SHOWN NGROL D MAY' E F,tLED. SYMBOL ON EACH LABEL THE ANSI STANDARD O O REQUIRES A HEADING THAT IS AT LEAST 501ATALLER NEC 690.31(G)(3)AND IN 605.11.1 NEC 690.56(B) NEC 690.35(F) THAN THE BODY TEXT,IN ACCORDANCE WITH NEC 110.21(B). SWl-DISCONNECT EACHDISCONNECTINGMEANSFOR Lu W O4 O DC DISCONNECT01) O AC DISCONNECT(SWI) APERMANENT PLAQUE OR DIRECTORY SHALL BE 1— 0 EATON OG222NR8 PHOTOVOLTAIC EOUIPMEM(J81,SW7,11) INSTALLED PROVIDING THE LOCATION OF THE SERVICE 3 DISCONNECTING O4 O O NS AND THE PHOTOVOLTAIC O O � �.j SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME } W I:zr - E C GO T H LOCATION IN ACCORDANCE WITH NEC 690.56(B). � 0 60- M 11-INVERTER LOA 3MA F L CEO N LABEL(S)WITH MARKING,'WARNING PHOTOVOLTAIC W SOLAR EDGE SE7600f4US POWER SOURCE;SHALL BE LOCATED AT EVERY 10 W .__I T, FEET OF EACH DC RACEWAY AND WITHIN ONE FOOT OF � w N L3-. EVERY TURN OR BEND AND WITHIN ONE FOOT ABOVE O O O NEC 690.17(E) NEC690.53 NEC 690.64 4 AND BELOW ALL PENETRATIONS OF ROOF/CEILING Q to ASSEMBLIES,WALLS AND BARRIERS.THE LABEL SHALL J ANY AC ELECTRICAL PANEL THAT IS FED BY HAVE 3/6'TALL LETTERS AND BE REFLECTIVE WITH ir .__I MSP-MAIN SERVICE PANEL O ACSOLARDISCONNECT(SWi) O8 SEENOTEN0.5(SW1) O9 BOTH THE UTILITY AND THE PHOTOVOLTAIC REDBACKGROUND O 'a' _ SYSTEM(SW1,MSP) LABEL(S)WITH MARKING,'PHOTOVOLTAIC SYSTEM = M O O EQUIPPED WITH RAPID SHUTDOWN;SHALL BE LOCATED �' Lo >- G� AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE } _ • •• I WARNING I v DISCONNECT THE LABEL SHALL HAVE 3/8'TALL 0 0 EL RAPID DU PO ER SOU - 'CONND S LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A W W WITH PfiOTL•pwjcS STEM REDBACKGROUND I N � W NEC 690.13(B) NEC 690.56(C)AND IFC605.11.1 NEC 705.12(DX3) 0 0 f� r 1� SAFETY'IA LS �///IIII11111, DOC ID:133173-165361-1 DATE:2125120 CREATOR: REVIEWER: REVISIONS PU ........ Electrical Specifications � Test Conditions STC T NOCT �� Module Power wp 310i 234 _ Maximum power voltage(Vpmax) V --33A5 29.7 Maximum power current(lpmax) A 9.38 7.88 �® Open circuit voltage(Voc) v 40.25 37.2 �� Short circuit current(Isc) A 9.93 8.14 (' ' ' Module efficiency % 19.0 17.9 r$OLAR Maximum system voltage(VDC) v 1000 Series fuse rating A 15 Power Tolerance Wp -0/+5 ® Measurementrcahb—anmfe ce ladut M15•Temperature 25Y•,dn char,de,A, •Measurement anrnrt 1by% r, •Sunamula rnddi.-reference 1.2-s(.5 FraunM1cf n,sn C peGnral charaRenslli1.s- vary Eyes%a caadndyy3 r.SW. Temperature Ratings Sl Temperature Coefficient Isc %/K 0.03 Temperature Coefficient Voc %/K -0.30 Temperature Coefficient Pmax %/K -0.38 100%MAXIMUM POWER DENSITY NOCT(t 2=c) C 45 ' ® Silfab's SLA-M 310 ultra-high-efficiency Operating temperature 'C -40/+85 modules are optimized for both Residential and Commercial projects where maximum power density is preferred. Module weight(t 1 kg) kg 19 Dimensions(H x L x D;t l mm) mm 1650 x 990x 38 100%NORTH AMERICAN Maximum surface load(wind/snow)• N/m' 5400 QUALITY MATTERS Hail impact resistance o 25 mm at 83 km/h Cells 60_Si monocrystalline-4 or 5 busbar•156.75 x 156.75 mm ensures fully-automated manufacturing facility Glass 3.2 mm high transmittance,tempered,andref!ctive coating • ensurees precision engineering is applied at Badrsheet Multilayer polyester-based every stage.Superior reliability and performance Frame Anodaed AI- combine to produce one of the highest Bypass diodes 3 diodes-45V/12A,IP67/IP68 quality modules With the lowest defect rate Cables and connectors(See installation manual) 1200 mm o 5.7 mm(4 mm2),MC4 compatible in the industry. NORTH AM ERICAN Module product warranty 12 years - CUSTOMIZED SERVICE 25 years - Silfab's 100%North American based team z 97%end of 1°year leverages just-In-time manufacturing to deliver Linear power performance guarantee z 90%end of 12'year a 82%end of 25�year unparalleled service,on-time delivery and flexible project solutions. rimtl Product ULC ORD C1703,UL 1703,IEC 61215,IEC 61730,IEC 61701,CEC listed e _UL Fire Rating:Type 2 hype 1 on request) Factory 1509001:2008 s Warning:Read[he installation and User Manual before handling,Installing and operating modules. •,n....e f, Third-parry generated pan files from ���•"ate r , ,I , ` • PV Evolution Labs available •- I r for download at: /lq • �, www.silfab.ca/downloads 11H Pallet Count:26 $ 11 Container Count:936 $t• Silfab _ row M Silfab Solar Inc. •�• , 240 Courtneypark Drive East•Mississauga, m-••••� a•••�•.. Ontario Canada LST 255 a - Tel+1 905-255-2501•Fax 905-696-0267 3 info@silfab.ca•www.silfab.ca / Power Optimizer -� For North America Power Optimizer O P320/P340/P370/P400/P405/P505 For North America "" P320/P340/P370/P400/P405/P505 .dul�s) I"'"' INPUT Rated Input DC Power 320 340 3]0 400 405 505 w Ab:owre Maxunum mP,t Wltage 48 10 80 1251 83ro We — — O (Vac at bwcs e raWre) h1PPT CperapM ng P Rannge 8-48 8-6D 8-80 125-105 12.5-83 We Maze Short Crt KCun 11 50.1 14 Adc . '1 la T W.—DC MN Current 13.75 12.63 17.5 Mc v Maximum Eft—ncy 995 % Vleght Efficrency 98.8 ye.6 % O—ft ge Category i 8 �I OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current I 15 Atic Maximum Output WRage 60 BS We OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) se Output Wltage per 1 x 0.1 We Powr Opbmleer STANDARD COMPLIANCE Eh1C FCC Part15 CWss B,IEC6100D-6-2,IEC61000-6-3 Sa`ety RC62109-1(Vass D safety),U11]41 R Hs Ip INSTALLATION SPECIFICATIONS hU.—Alb-d System 1000 We hag. Compatible—a- AO 5o1arEdge 5,n91e Phase and Three Phase inverters D—som(Wx Lx H) 128.152 x 28/5x 5.97.1.1 128x152x 161 128x152x50/ 128x152'59/ mm/in 5 x5.9]x1.42 5x 5.97 x1.96 5x 5.97 x 2.32 Weight(,Kluding cables) 630/14 750/1.7 845/1.9 1064/23 gr/lb Input Connecor MC41 atNt Wire Type/Connector Double Insulatd;h1C4 atNt Wire Length 095/3.0 1 1.2/39 m/k Input%re LeNth 0.16/0.52 Operatlrg Temperature Range -00-+AS/-00-.185 PV power optimization at the module-level POteRlon Rating IP68/NEMA6P Rehm Humldny 0-100 % m Pmed SiC pacerNMe rtaduk MWae of up m•0%po-er mlerena ahwM u�NEC 7017 re9ulms msx mWt sah pe pe nm mot Man BOV / Specifically designed to work with SolarEdge / Fast installation with a single bolt maprevxa mnntcm�rype'paam tame saerEage inverters / Next generation maintenance with module- / Up to 25%more energy level monitoring • r h6nirtwm SVvg Lergth P P340,P3R1, B 10 18 / Superior efficiency(99.5%) / Meets NEC requirements for arc fault (wwr opt—er') Pms/Pros fi e 14 protection(AFC[)and Photovoltaic Rapid M—m Stang LmgN / Mitigates all types of module mismatch losses, Shutdown System(PVRSS) p crow`ommi: ') 5700(600Dw h 2s 2s som from manufacturing tolerance to partial Manmom per Sm g SE7600-US-SE11400- 525D .1 1275M' W shading / Module-level voltage shutdown for installer Paralhlsv� u rgs of DMerent Lengths 1N5 and firefighter safety oronentatons / Flexible system design for maximum space •PwdamneatMrsg-alagma�mmr„,rekrm ntro7n,ww:aaredgemrnm�ner�,lrmkvsang_Ppng.mwr m It rs na eYaveE tp mix Po05?505 wM P3i0Na10/P3)04'40p In arse stung utilization A, gore Men 30 Opmnizers does urn meet NEC raptl9mMrnrn requremems,sakryvatage MII Ee abpe[he 30V requirement ^Fa SEI44KUShEd1.7KUS.a 1s a:b-xd ro IrnmA up 11 p 11 persmng ssfien 3 9nngsare connectMro Me Inserter D smngs R'r unn(or gEa31KU0)an0-Men Mem30WS/pourerd1 `6 Mween Mes't Is upm 1.000W -SE30KUS/SE31.lKUS/BE066K11075E100KU5'6 rs alloxred m Install up m 15.OW W per stMg when)Mugs art connMM ro Me Inserer(3 Mngs per unit br sE66.6KUSrYE]OOKUS) end when Me maximum pvmr dlHerenm betrrecn Me svmgs rs up ro7,000W solaredge.com solar • • = ........p �;��,� �p� p�o .re.e��d .�4tmam�rm� .t�a g�.� t .re mtp4 MwM� mmtM CC RoHS FA,kT*N Product compliance:No Data Powering Business Worldwide pe.eaton.com ©2016 Eaton.All rights reserved. Eaton general duty cartridge ' fuse safety switch DG222NRB UPC:782113144221 Dimensions: •Height:14.38 IN •Length:14.8 IN Width:9.7 IN Weight:10 LB Notes:Maximum hp ratings apply only when dual element fuses are used.3-Phase hp rating shown is a grounded B phase rating,UL listed. Warranties: • Eaton Selling Policy 25.000,one(1)year from the date of installation of the Product or eighteen(18)months from the date of shipment of the Product,whichever occurs first. Specifications: •Type:General duty,cartridge fused •Amperage Rating:60A •Enclosure:NEMA 3R •Enclosure Material:Painted galvanized steel •Fuse Class Provision:Class H fuses •Fuse Configuration:Fusible with neutral •Number Of Poles:Two-pole •Number Of Wires:Three-wire Product Category:General duty safety switch •Voltage Rating:240V Supporting documents: •Eatons Volume 2-Commercial Distribution •Eaton Specification Sheet-DG222NRB Certifications: • UL Listed Af Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/ Single Phase Inverter Z SE760OH-US/SE1000OH-US/SE1140OH-US with HD-Wave Technology <T OUTPUT to FF FF FF F ■ ■ Rated AC Power 3Bm @ 240V 600D @ 208V 1N00 @ 240v Q'tput 3000 33W @ 208V Sf10D 5000 @ 209V 76W 10m0 t00W @ 209V VA M.—m AC Power Output 3o0p 380D @ 240V SOm fi0o0 @ 240V 7600 M)RO 11400 @ 240V VA for North America T 33W@ 08V woo@2 V 1oom@2oev AC Gnput Wltage Mn:Nom-Max. V V V ♦ Uac SE3000H-US/SE3800H.-US/SE5000H-US/SE6000H-US/ _I AcOul8-264) _1 083-203 229) W.-N.—Mu. Vac SE760OH-US/SE1000OH-US/SE1140OH-US ACFm u—y(1) �„� AC FrequencylWmtnaq 593-w-60.5^' Nz Maximum Con—ms Output 125 16 21 1 25 32 42 475 A p np.Y re�^ro Maximum Continuous Output ool Current @2DBV 16 2a d85 A GFDI Threshdd 1 A N UtIq W,,tonng.lsland,,g ProtMon,Country C-figurable 1Ns INPUT •s ='"'i`z' :'1"'�u ',',� �i'0: V J Maximum DC Power @240V 4650 59m 77w 93m 11900 15500 1]6w W Maximum DC Po-@mBV - 5100 ]]w - - 155m W Transformer less Ungrounded Y s ' Max mum Input Voltage 480 We Nominal DC Input Wbbge 380 4m We Maximum Input Current@240V" 85 10.5 13520 27 30.5 Adc p ?;.:, s'p Maximuminputcurrent@2BBW - 9 - 13.5 - - 27 Adc Max.lnput Short Crcut Current 45 Adc /"*' ""'It!tf p 'or @ Reverse Polarry Pmtectwn Yas Ground-Fault Isolation Detwon RkO Se,&q Maxmum Inverter EPzency 99 992 % CEC Wegh[ed Eficenq 99 99 @ 240V % Nighttime Power Consumptwn r W ADDITIONAL FEATURES Supported Com...i tbn Interfaces RS4e5,Ethernet Z1,(optbnap,Ce[Wr(optb,,4 Revenue Grade Data,ANSI 0220 Oplbn.M Rapd Shutdown-NEC 2014 aM Automat[Rapid Shutdown upon AC GM O.,mnnea Optimized installation with HD-Wave technology 28,7690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL16998,CSA C22.2,Canadian AFCI accodingto T.I.L.M-W / Specifically designed to work with / Extremely small Grid Connection Standards IEEE1547,Rule 21,R,k 14 NO power optimizers Emt:,bne IFCC Past 15 CW,s B / Record-breaking efficiency / Built-in module-level monitoring INSTALLATION SPECIFICATIONS AC MW C.M,See/AWG 3/4'minimum/14-6AWG 3/4'm.—/14d AWG Range / Fixed voltage inverter for longer strings / Outdoor and indoor installation DC Input Conduit Size/P of Strings/ 3/4'minimum/12 strings/14-6 AWG 3/4'mmimum/13 Wrings/14-6 AWG AWG Rance / Integrated arc fault rotectionandra Id shutdown for p 9 D�menF.onawttnsabtyswttm 17.7x14.6x6.0/450x370x174 21.3x14.6x7.3/540x370x185 9 p p / Optional:Revenue grade data,ANSI C12.20 (HM.D) NEC 2014 and 2017,per article 690.11 and 690.12 Class 0.5(0.5%accuracy) Weght thSaretysw4ch 22/w 25.1/11A 26.2/1L9 388/17.6 m/Eg Noise '25 <50 dBA / UL1741 SA certified,for CPUC Rule 21 grid C-g Natural mnve�twn compliance ON Ang Temperature Range 40[o•140/-25 to.mw 40(- 'F/40'C optton)w 'F/'C Pmteetwn Rating NEMA 4x(Inverter with Safety Switch) F.oMer reg mal se rgF pkasamntnn So 1r aPPa+F 3', ,'solar wA 9er ro m �u��et ,N,wal.mlttitroatN�nrwp rove, �4 •aerenue Qade t^K�rercm sE�w4lsoopHr+a sclafedge.com v F�po^erde+aorq lnro,maran relr ro:tux,,w.wwt,reogecmVv:„xraave:.,n<-m,perawre cerarw,nom,x,,.r uenim PM SEnN1U5rppt✓H W ROHS i .orlc� . 'b TT t vol ivo fit T iF � �" ��!: ����q..-'•IG T S� ��' ems}.,N t,�.+-"',. ;,a.'x'S y+bpi. '4" k `R `.4 }: »f .a f xr �k $� `»uS-"s--'A .+ llFt "' '�•, r e i ."" ""K. ok Akl WVT IL Om ^ y ,ip yak:... 4, ty., ` '.`•F ,yL•b,�y,.. , . . ,fir .gyp., IL x 'sK ' �."4�����lv�� •it �M1 M! ... �4 1! � ,k� � � �' �Kv �iS.- �* yM�F������v'` DocuSign Envelope ID:87315599-4694-4BA7-A1A5-9B6B834FB903 SOLAR°BEAR SOLAR BEAR LLC 6101 Johns Road,Suite 8,Tampa,FL 33634 Your Solar Solutions Provider (727)471-7442 W W W.OU RSO LAR B EAR.CO M EC13009020 SOLAR HOME IMPROVEMENT AGREEMENT DATE: CUSTOMER NAME(hereinafter,the"Customer") 02-17-20 Delroy Thomas ADDRESS: 5904 9th st CITY,STATE,ZIP:zephyrhi l l s, Fl 33542 HOME PHONE NUMBER: WORK PHONE NUMBER: MOBILE PHONE NUMBER: Na 305-363-8960 EMAIL: Marleymech8@gmail.com This Solar Home Improvement Agreement(this"Agreement")is between Solar Bear LLC("Solar Bear","we"or"Contractor")and you("Customer")for the sale and installation of the solar system described below(the"Project"or the"System")at your home (the"Property"or your"Home").The Parties agree as follows: 1.Was a full years usage of the customers electric bills provided? YES x❑ NO F 2. If no, does the customer understand we can not guarantee a 95%-105%of the previous YES NO years usage. El 3. Does the customer understand the 26%TAX CREDIT is based on their taxable income?YES FX NO IF YOU DO NOT PAY INCOME TAXES YOU DO NOT GET A TAX CREDIT PROPOSED SYSTEM SIZE PURCHASED SYSTEM SIZE (Based on 12 months previous usage) 8.37 KW 11,640 KWH ANNUALLY 8.37 KW 11,640 KWH ANNUALLY CONTRACT PRICE AND TERMS OF PAYMENTS. I understand,that if I cancel, I will be held financially responsible for the cost of the permit and any work that Total System Cost: 34,306 may have take 6 gg,,ea by. Check Here If Any Portion of the project Sign � by fG bwtaS Total System Cost is Financed. 2/19/2020 If checked,the Customer will receive a separate Date agreement from the Finance Provider outlying their terms and conditions. AMOUNT PAID TODAY:$ 0 BALANCE REMAINING:$ 34,306 os •An explanation of the Recommended System Size has been explained to me and I have a copy *An explanation of the Federal Investment Tax Credit(ITC) has been explained to me and I have a copy INITIAL NOTICE OF RIGHT TO CANCEL THIS IS A LEGAL BI NDING AGREEMENT AND YOU MAY ONLY CANCEL THIS AGREEMENT PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE YOU SIGN THIS AGREEMENT.TO CANCEL THIS AGREEMENT,PLEASE SEE THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF TH IS RIGHT.THANK YOU FOR YOUR ALLOWING US TO SERVE YOU I Ooo6p d°" 2/19/2020 Customer Signature: �i1oy,?0 as Date: Customer Signature: Date: 2/19/2020 Representative: I 'G` Date: ♦ i ,. , v.yam_ ;,�• City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: slkr &_ Date Received: 7— Site: �CS' Permit Type: Approved w/no comments. Approved w/the below comments: El Denied w/the below Lfments9❑ This comment she shall erlc pt with the permit and/or plans. MAP 1 P 9"9h Kalvin . i —Plans Examiner Date Contractor and/or Homeowner (Required when comments are present)