HomeMy WebLinkAbout20-22716 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 22716 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 22716 Address: 6329 COBBLE.BLISS ST Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: SILVERADO - Est. Value: Parcel Number: 04-26-21-0110-00900-0020 Improv. Cost: 1,190.00 OWNER INFORMATION Date Issued: 4/13/2020 Name: COYNE, WILLIAM & PAULA Total Fees: 150.00 Address: 6329 COBBLE BLISS ST Amount Paid: 150.00 ZEPHYRHILLS, FL 33541 Date Paid: 4/13/2020 Phone: 386-852-8744 Work Desc: CONSTRUCT SCRN RM 15 FT X 23 FT W/ CONCRETE PAD CONTRACTORS APPLICATION FEES TRUE ALUMINUM INC BUILDING FEE 150.00 Ins ections Re wired FOOTER 2 D ROUGH PLUMB MSC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY— PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental . entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. &___ bze� CTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received O 3 Phone Contact for Permitting ) [ — .aaaaaaaa aaaaa Owner's Name 1`1 CA Owner Phone Number Owner's Address 2-pp (�� `o LL l,� Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS J 2 l� b b'k- LOT# /t CO SUBDIVISION PARCEL ID# V Z - • 0 0 1 W L)Q 2-0 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW INSTALL STR B REPAIR SIGN = = DEMOLISH PROPOSED USE = SFR Q COMM = OTHER TYPE OF CONSTRUCTION = BLOCKp �Q/� FRAME = STEEL = DESCRIPTION OF WORK /� Q2/(�T�C 2 BUILDING SIZE I�/ l 2A SQ FOOTAGE ✓ -1 J HEIGHT t ''C'C_I" "�- C"t t"S"q-���"�[-i�C�['�"�C"['4-��";"�S-S-�i L BUILDING $ qQ O �G�/ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ �^✓ AMP SERVICE PROGRESS ENERGY Q W.R.E.C. =PLUMBING $ 1fj5 2 /Z_1& =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS SPECIALTY ' FINISHED FLOOR ELEVATIONS ROOFING FLOOD ZON ARE,q OTHER NO BUILDER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# OTHER I� OMPANY r A It,rv�l,tiloop SIG URE REGISTERED Y/N FEE CURREN I Y/N q Address License# I S C C S S f aaasaaaaaasaasaaasafaaa7aaaaaaaaaaaaialasaaalaasat!afaaEiaialaaasIaal RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-002U City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowners Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner',I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF C MMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU I END TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER QR AN ATTORNEY BEFORE REQ RDINGYOU NDTICE OF COMM EU CEM") FLORIDA JURAT(F.S.117.03) OWNER OR AGENT NTRACTO Subscribed and swom to(or affirmed)before me this and by om r affirmed)before me thisby Who is/are personally known to me or has/have produced Who is/ personally known to me or ha's/have produced as identification. 6e as.identification. �`y^`Q roLv Notary Public pal ,//�� 2 Notary Public Commission No. Commission No. l7&3;1 V3 I Name of Notary typed,printed or stamped Name Of Notary typed,printed or sfamped otAY EMILY SIKES Notary Public-State of Florida Commfssion k GG 317631 My Comm.Expires Apr 14,1013 Bonded through National Notary Assn. 01 0 (r% _ AS BUILT SURVEY(FINAL) SEC.. 04 , TWP.--.96 S, RNG. 21 E. LOT 2, BLOCK 9 BEARING BASIS: SILVERADO RANCH SUBDIVISION PHASE 5A PASCO COUNTY, FLORIDA. WEST BOUNDARY OF SUBJECT PLAT BEING N 36*42'29" E THIS SURVEY IS SUBJECT TO ANY FACTS THAT LEGTrND: MAY BE DISCLOSED BY A FULL AND ACCURATE E-000.0' - EXISTING GRADE N TITLE SEARCH. ALSO SUBJECT TO SETBACKS, PREPARED FOR AND CERTIFIED TO: EASEMENTS AND RESTRICTIONS OF RECORD. 4� e ROYAL PALM CALATLAINTIC TITLE INC- UNDERGROUND FOOTER, STEM WALL, AND 2'MAPLE CHICAGO TITLE INSURANCE COMPANY UNDERGROUND UTILITIES ARE NOT LOCATED OR EAGLE HOME MORTGAGE,LLC 11 SHOWN. svy WILLIAM R.COYNE 00 NOT SCALE THIS PRINT. DIMENSIONS AND 2'MAGNOLIA PAULA GEIGER COYNE NOTES TAKE PREFERENCE. 2'OAK PURPOSE OF SURVEY. TO OBTAIN HORIZONTAL AND/OR VERTICAL DIMENSIONAL DATA TO SHOW CONSTRUCTION IMPROVEMENTS. 10' UTILITY EASEMENT LOT I$ BLOCK 1 SILVERADO RANCH PHASES 2 3&4 (PLAT BOOK 73.PAGE 59) PLAT BOUNDARY Olt LOT 3 BLOCK 9 rD b 8 TRACT A - '5' DRAINAGE AREA SLVERADD RANCH PHASES 2,3&4 (PLAT BOOK 73,PAGE 59) 67 41 LOT 2 BLOCK 9 4, E-107-6 A:, 7 Lt T 'V 01 7 '!CG A, is LOT I BLOCK 9 A, 5 S 41 LOWEST FLOOR ELEVATIONS: LIVING AREA: 108.17' DESCRIPTION: GARAGE AREA. 107.67' LOT 2, BLOCK 9, MAP OR PLAT ENTITLED "SILVERADO RANCH ELEVATIONS REFERENCED TO NORTH AMERICAN VERTICAL SUBDIVISION PHASE 5A", AS RECORDED IN PLAT BOOK 078, PAGES 033 DATUM OF 1988. MEAN SEA THROUGH 037, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101C 0451 F & 0452 F EFFECTIVE DATE! 9/26/14 ISquare Feet: 7542.52 t LENNAR HOMES [ECENO (BFE)=:BASE FLOOD ELEVATION, (C)= CALCULATED DATA, (D)= DEED DATA. (M)- MEASURED DATA. (P)= PLAT DATA,rL- CENTERLINE, A/C= AIR CONDITIONER, B/C- BACK OF CURB,C/S-CONCRETE SLAB. CH-CHORD, CHB= CHORD BEARING. CUF= CHAIN UNK FENCE, CONC.- CONCRETE,COV.- COVERED, E/P= EDGE OF PAVEMENT,ELEV= ELEVATION, ESM'T- EASEMENT,F/C- FENCE CORNER, FCM- FOUND CONCRETE MONUMENT, FIP- FOUND IRON PIPE, FIR- FOUND IRON ROD, FN&O.FOUND NAIL &DISK,FFF- FOUND PINCHED PIPE.LFE= LOWEST FLOOR ELEVATION, MAS.- MASONRY, O.R­ OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP- PERMANENT CONTROL POINT, PRM=PERMANENT REFERENCE MONUMENT, R/W=RICHT OF WAY, R-RADIUS, (R)-RADIAL, SIR=SET 1/2-IRON ROD &CAP #4493, SN&D- SET NAIL&DISK #4493, TBM= TEMPORARY BENCHMARK, U/P- UTILITY POI-E, V/F- VINYL WCF_ ;/F= WOOD FENCE, ALUM. FENCE- ALUMINUM Brown y., HLRE CEFFr_. _IAADE__UNDFR MY 'RT B I �T 11-115 �IUKVLT WAS JOHN R.BEACH&ASSOCIATES,INC. sms RESPONSIBLE CHARGE AND MEETS THE APPLICABLE STANDARDS OF SURVEYORS AND MAPPERS Checked By. PRACTICE FOR SURVEYS AS SET FORTriBY THE-FLORIDA BOARD OF t 911 WEST ST. PETERSBURG DRIVE JREI LAND SURVEYORS IH CHAPTER S&L 7.051 THROUGH 5J-17.053, ONE OLDSMAR,FLORIDA 34677 FLOR A A ISTRATIVE CODE, PURSUANT TO SECTION 472.027 WAY (813) 854-1275 FAX(813) B55-8370 Scale: FLO D A STA NOT VAUD WITHOUT ORIGINAL SIGNATURE IDate: I DATE AND THE RAISED SEAL OF A FLORIDA FINAL 8/23/19 DWB A �LICENSED SURVEYOR AND MAPPER JOHN R. BEA Rvvlvlonw FORM ORD TIE IN 5/21/19 JMM, REVISED PER STREET NAME 5/30/19 JOS, REM FLORIDA REG. AND SURVEYOR NO. 2984 LB#4493 PER SCI=Egglojg'��6ffi 9 JOS, FOUNDATION TIE IN 6/-3/19 JMM n JEFF_'A�T X,:, 0 1:� 49FESS11O.AL SURVEYOR &MAPPER No. 7123 ,i • 7 i 1 City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: ��� �V)t n L)yt� Date Received: Site: 6 3 °�1 Permit<Type: C ' Z—COKCce-l-le Approved w/no comments: Approved w/the below comments: 0 Denied w/the below comments: El F} This comment sheet be kept with the permit and/or plans. NAR 2 9 2020 Kalvin Sw' er h6s Examiner Date Contractor and/or Homeowner (Required when comments are present) INSTR#202000S798 OR 6K 10092 PG 2572 Page 1 of 1 04/27/2020 02:53 PM Rcpt:2156868 Rec: 10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles, Esq.,Pasco County Clerk&Comptroller Permit No. Parcel ID No NOTICE OF COMMENCEMENT State of County of THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information Is provided in this Notice of Commencemen 1. Description of Property: Parcel Iden(ification No. — 21 1 — ` Street Address: e,. A-, 1` 3 S LI I 2 General Description of Improvement .e. 3. Owner Information or Lessee information if the Lessee contracted for the Improvement: —113 ZA C ob\AL b k.t s S ti��1S 33sc.� Name Address City State Interest in Property: Name of Fee Simple Titleholder. (If different from Owner listed above) Address City State 4. Contractor. Name '� 1.C Address ^ ^ ! ^ _ City State Contractors Telephone No.: 5. Surety. Name - Address _ City Stata Amount of Bond:$ Telephone No.: 6. Lender. Name Address City Slate Lendefa Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(t)(a)(7),Florida Statutes: Name Address City State Telephone Number of Designated Person: 8. In addition to himself,the owner designates of— to receive a copy of the Lienofs Notice as provided in Section 713.13(1)(b),Florida Statutes, i Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED;IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing no ce at commencement7andtt the fads stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO' gnat f Owner orLess ,ar.. s or Lessee's Authorized Officer/Dlrector/Partner/Manager Sign�attoo�ys�Title/Office j The foregoing instrument was acknowledged before me IN ��day of YNrI t .20�by T I as (type of authority,e.g.,officer,trustee,attorney in fact)for - (morn t party on ,half of om Instrument was executed). j Personally Known❑M Produced I�dentifiratio Notary Signature l n( i Type of Identification Produced 4J� Name(PdnQ l S t i►t��� EMILYSIKES Notary Public•State of Florida Commission#GG 327631 i dr r� My Comm.Expires Apr 24,2023 Bonded through National Notary Assn. wpdate/bcs/noticexwmmencement�c053048 • I I state Of Florida,County Of Pasco This is to certify that the foregoing is a •, true and correct copy of the document on file or of public record in this office. a a W'4. my hand nd offlCial seal this ,.- 'ay of V 2 � Nikki Alvarez-Sol 1887e ,Esq.,Clerk&Comptroller a ° Pasco nty,Flori �'3� �F�®RHO gy , Deputy Clerk General Notes 2.HEX BOLTS HAS TO BE ASTM A 325,PLATED WITH STANDARD ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED FLAT WASHERS AND NUTS. HOME. A.CONCRETE&FOUNDATION DESIGN: 3.ALL CONCRETE SCREWS SHALL BE,SIMPSON,HILTI,RAWL, 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA,THE 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 TAPCON,REDHEAD,DYNABOLT,PORTECT OR APPROVED ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING PSI MINIMUM. EQUAL. BARRIER REQUIREMENTS OF THE FBC 6th EDITION R 4501.17 IN 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE ITS ENTIRETY. MINIMUM,3 1/2"NOMINAL THICKNESS. HOT DIPPED GALVANIZED. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY 3. FIBERMESH(3/4"PER CUBIC YARD MIN.)MEETING 5.ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X CONTRACTOR. APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED BOLT DIAMETER INTO STRUCTURAL FRAMING(G=.42 MIN.). 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL IN LIEU OF WELDED WIRE MESH 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, 4. ALL SLABS ON GRADE SHALL BE 4"THICK WITH FIBERMESH. PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT ENSURE BONDING AGENT IS USED FIRST AND ADHERED WITH 5. ALL REINFORCING SHALL CONFORM TO ASTM A615,BE GRADE GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF MINIMUM 3000 PSI GROUT. 60(60 KSI MIND DEFORMED BARS,#3 BARS MAY BE GRADE 40 THE BOLT OR SCREW.ALL LAG BOLTS AND SCREWS SHALL BE 5. SCREENING MATERIAL SHALL BE 18X14X0.013 OR 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL INSERTED IN PILOT HOLES BY TURNING AND UNDER NO EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED BE 3000 PSI MIN.,2"MINIMUM.THICKNESS. CIRCUMSTANCES BY DRIVING WITH A HAMMER. ON DRAWING S-2. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 7.ALL EXPANSION ANCHORS SHALL BE DESIGNED IN PROFESSIONAL ENGINEER SEAL 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S ENGINEER OF RECORD: FOLLOWING: REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY OPC(PORTLAND CEMENT TYPE 1,-ASTM C 150). BE APPLIED IN CONDITIONS ACCEPTABLE TO David Y Y. Smith P.E. AGGREGATES-#6 STONE,ASTM C 33 SIZE NO.67 LESS THAN MANUFACTURER.FASTENERS SHALL BE A MINIMUM OF SAE �A� 3/4". GRADE#5 OR BETTER ZINC PLATED. FLORIDA LICENSE:53608 AIR ENTRAINING+/-1%-ASTM C 260. 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR DESIGN DATA: Thomas L. Hanson P.E WATER REDUCING AGENT-ASTM C 494. PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 1. ULTIMATE DESIGN WIND SPEED Vult,(3 SECOND GUST): 140 MPH CLEAN POTABLE WATER 18-8,UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES NOMINAL DESIGN WIND SPEED Vasd: 108 MPH FLORIDA LICENSE:38654 OTHER ADMIXTURES SHALL NOT BE PERMITTED. FOR USE WITH ACQ PRESSURE TREATED WOOD,OR 2. RISK CATEGORY: B Myron Max Neal P.E. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. OTHERWISE NOTED ON PLANS. 3. WIND EXPOSURE: Y 10.PREPARE&PLACE CONCRETE ACCORDING TO AMERICAN 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. 4. WIND LOADS: FLORIDA LICENSE:86663 CONCRETE INSTITUTE MANUAL STANDARD PRACTICE,PART 1, 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 SCREEN ROOF: N/A 2,&3 ALONG WITH HOT WEATHER CONDITIONS CLASS G-185. SCREEN WALLS: 27 PSF Joel Falardeau P.E. RECOMMENDATIONS. 11.FOR SMS,THE MINIMUM CENTER-T0.CENTER SPACING SOLID ROOF(SCREEN WALL): 23 PSF FLORIDA LICENSE:70667 11.IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, SHALL BE 3/4"AND MINIMUM CENTER-TO-EDGE SHALL BE 1/2" CONCRETE SHALL BE A MINIMUM OF 4"IN THICKNESS, UNLESS NOTED OTHER WISE. 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X14X0.0I3 Erik Stuart P.E. VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, OR EQUIVALENT DENSITY SCREEN MESH: 0.88 FLORIDA LICENSE:77605 SPALLING OR OTHER DETERIORATION. E.REFERENCE STANDARDS: 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 ASTM E 119 7. LIVE LOAD: B.MASONRY: ASTM E 1300 300 lb.VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. FBC Plans&Engineering 1.CONCRETE MASONRY UNITS(CMU)SHALL BE STANDARD CURRENT ASCE 7 200 1b.VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. Services Inc. HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON CURRENT ALUMINUM DESIGN MANUAL-AA ASM35,AND SPEC. 10 P°F VERTICAL DOWNLOAD ON SOLID ROOF. TYPE M OR S MORTAR FOR ALUMINUM PART 1-A,&1-B 8. PROPOSED 3"X8"W/(1)#5 REBAR W/25"OVERLAP ON 3"CHAIRS W/4"MONOLITHIC 6272 Abbott Station Dr.Unit 101 2.ALL MORTAR SHALL BE OF TYPE M OR S. ASTM C94 SLAB W/FIER-MESH FILLED W/3000 PSI SHALL BE ADEQUATE TO RESIST THE Zephyrhills,FL 33542 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE ASTM C150 UPLOADS FOR THE PROPOSED STRUCTURE. Ph#(813)788-5314 MAXIMUM COARSE AGGREGATE SIZE OF 3/8". ASTM C33 9. SCREEN ROOF TYPE: N/A 4. Fax#1-(866)824-7894 PROVIDE CLEAN-OUTS FOR REINFORCED CELLS CONTAINING ASTM C260 10. SOLID ROOF TYPE: 3"X48"X0.030"ELITE EPS COMPOSITE PANEL ROOF 11b FOAM REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0"IN ASTM C494 DENSITY,FLORIDA PRODUCT APPROVAL,FL 7561-R4. E-mail-erb@fbcplans.com HEIGHT. ASTM A615 Website www.fbcplans.com ASTM A185 C.O.A.-#29054 C.ALUMINUM: FLORIDA BUILDING CODE 6th EDITION (CHAPTERS 16,20&23). 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE ALUMINUM STRUCTURAL MEMBERS MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A u,p DATE: 03/11/2020 MINIMUM THICKNESS OF 0.040"FOR SUPPORTING MEMBERS. F.ABBREVIATIONS: REVIEW DATE,J _Z 0 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED HOLLOW SECTIONS DRAWN BY:ST 0.024"SHALL APPLY. TO REPRESENT ALL THOSE USED ON THESE DRAWINGS,BUT 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO"PART 1-A- 2 x 2:---------------------------------------2"x 2"x 0.044" CITY OF ZEP �YRH SPECIFICATIONS FOR ALUMINUM STRUCTURES-ALLOWABLE TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 2 x 3:---------------------------------------2"x 3"x 0.050" p(AN EXAMINER REVISION: DATE: STRESS DESIGN"OR"PART 1-B-SPECIFICATIONS FOR 1. SIMTYP-TYPICAL 2 x 4:---------------------------------------2"x 4"x 0.050" 2.SIM-SIMILAR RO 1 ALUMINUM STRUCTURES-BUILDING LOAD AND RESISTANCE 3. UON--UNLESS OTHERWISE NOTED 2 x 5:---------------------------------------2"x 5"x 0.050" FACTOR DESIGN"OF THE ALUMINUM DESIGN MANUAL 4.CONT--CONTINUOUS 3 x 3:---------------------------------------3"x 3"x 0.125" �n�t PLY �sREVAI 2 PREPARED BY THE ALUMINUM ASSOCIATION, 5. VIF-VERIFY IN FIELD AL.L1N ` INC.WASHINGTON D.C.THE FLORIDA BUILDING CODE 6th RO 3 EDITION(CHAPTER 16 STRUCTURAL DESIGN&CHAPTER 20 OPEN BACK SECTIONS CODES FLORIDABUC D HG CODE, G.RESPONSIBILITY: ALUMINUM). 1 x 2:----------------------------------------1"x 2"x 0.040" NATIONAL ELECTRIC ZEPHYRH�L�-S RO 4 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL,OR 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING 1 x 3:----------------------------------------1"X 3"x 0.045" AND THE CITY Job# 20_0311...192 PRESSURE TREATED LUMBER PROVIDE DIELECTRIC CODES,LOCAL ORDINANCES,ETC. ORDINANCES SEPARATION. CONTRA CTOR RACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, PROJECT ADDRESS: 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS 2. SNAP SECTIONS J 4 THAN#10 SMS 6"FROM THE ENDS AND 12"ON CENTER,IF NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS,FABRICATED ITEMS,OR ACTUAL FIELD 2 x 2 SMS:----------------------------------2"x 2"x 0.045" COYNE USING#12 SPACING MAY BE 24"ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE.THEY CONDITIONS. 2 x 3 SMS:---------------------------------2"x 3"x 0.072" 6329 COBBLE BLISS ST SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 2 x 4 SMS:---------------------------------2"x 4"x 0.045" ZEPHRYHILLS, FL 33541 "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND 'SUNROOM'ROOM ADDITION ELEMENTS AS PROVIDED BY THE 3 x 3 SMS:---------------------------------3"x 3"x 0.090" SPEEDS EXCEED 75 MPH".DECAL SHALL BE PLACED SO IT IS CONTRACTOR. VISIBLE WHEN PANEL IS INSTALLED. 4.ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED 7. 1"X2"X0.045"NON-STRUCTURAL MEMBERS SHALL BE ON INFORMATION PROVIDED BY THE CONTRACTOR AND SELF MATING (SMB) CONTRACTOR: ATTACHED TO HOST WITH l/4"0 X 1-3/4"EMBEDMENT&24" MANUFACTURER. 2 x 4 SMB:---------------------- 2"x 4"x 0.044"x 0.100" O.C.MASONRY SCREW FOR CONCRETE&EQUIVALENT SIZE 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A 2 x 5 SMB:---------------------- 2"x 5"x 0.050"x 0.118" TRUE ALUMINUM WOOD SCREW WHEN IN WOOD&#10X 1/2"EMBEDMENT SMS LICENSED P.E.IN ACCORDANCE WITH STANDARD 2 x 6 SMB:---------------------- 2"x 6"x 0.050"x 0.120" OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. ENGINEERING PRACTICES. 2 x 7 SMB:---------------------- 2"x 7"x 0.057"x 0.120" D.FASTENERS: H.MISCELLANEOUS: 2 x 8 SMB:---------------------- 2"x 8"x 0.072"x 0.224" 1. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A 2 x 9 SMB:---------------------- 2"x 9"x 0.072"x 0.224" 300 18-8,WITH STANDARD FLAT WASHER UNLESS MANUFACTURED HOME,TRAILER HOME,OR PRE-FAB HOME.IF 2 x 10 SMB:------------------- 2"x 10"x 0.092"x 0.374" MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE THE EXISTING STRUCTURE IS ONE OF THESE,A SEPARATE 4TH NOTES WITH ACQ PRESSURE TREATED WOOD. WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO TUBE SECTIONS S- 1 2x2:---------------------------------------2"x 2"x 0.090' • DOOR LOCATION MAY BE DETERMINED IN THE FIELD BY THE CONTRACTOR. -s jr 9' ...4"� �'-4"� PROFESSIOFIAL'ENGIIdEER SEAL 1 x2 ATTACH TO FASCIA 1X2 ENGINEER OF RECORD: I II David W. Smith P.E. III I 'III , FLORIDA LICENSE:53608 'ii ' III' ' Thomas L. Hanson P.E CO III I I III I (0 FLORIDA LICENSE:38654 • I x ,II II, X I Myron Max Neal P.E. III III T- I FLORIDA LICENSE:86663 111 II I III I Joel Falardeau P.E. 2x4SMB o of I , 2x4SMB I FLORIDA LICENSE:70667 OR 2X5 PT I wll ' 3" COMPOSITE PANEL ROOF II' OR 2X5 PT Erik Stuart P.E. �pII I SCREEN ROOM 'III I FLORIDA LICENSE:77605 C° ' ° III II' FBC Plans&Engineering III III i I Services,Inc. III 'II, cx i 6272 Abbott Station Dr.Unit 101 III' III I Zephyrhills,FL 33542 II —___ � 3-EpGE RM _ —— ——l I) Ph#(813)788-5314 __ Fax#1-(866)824-7894 E-mail-erb@fbcplans.com I , ,, Website-www.fbcplans.com 2 3 — C.O.A.-#29054 25'-0" PROPOSED 8"X 8" W/ DATE: 03/11/2020 MONOLITHIC SLAB DRAWN BY:ST REVISION: DATE: RO 1 R0 2 R03 x x x O N N N N N R04 job#20_0311_192 PROJECT ADDRESS: 2x3(typ) 2x3(typ) COYNEI 6329 COBBLE BLISS ST K.P.(typ) 1 x2 ZEPHRYHILLS, FL 33541 (typ) H CONTRACTOR: S-4 TRUE ALUMINUM FLOOR PLAN S-2 EXISTING HOST STRUCTURE BREAK FORM HEADER OR BREAK FORM HEADER OR RECEIVING CHANNEL - ` RECEIVING CHANNEL BREAK FORM HEADER OR `e.\ #10 SMS AT EACH RISER TRECEIVING CHANNEL FOR PAN OR#10SMS@ _ #10 SMS AT EACH RISER B"O.C.FOR COMPOSITE PANEL d SOLID ROOF FOR PAN OR#10 SMS @ 8"O.C.FOR COMPOSITE PANEL e `I •<? - d SOLID ROOF SOLID ROOF d A d n d #14 SMS@6"O.C. ✓. `4 FOR COMPOSITE PANEL #10 SMS @8"D.C. PROFESSIONAL ENGINEER SEAL FOR COMPOSITE PANEL 1-1/4" #10 SMS @ e"D.C. ENGINEER OF RECORD: (MIN) FOR COMPOSITE PANEL David W. Smith P.E. (4)#10 SCREWS PER 12" 1/4"X 3"CONCRETE ANCHORS(2)ROWS STAGGERED 24"O.C. WIDTH CONNECTING CONNECTING HEADER OR CHANNEL TO FASCIAPA FLjO,RIDA LICENSE:53608 OR TO BACK EADER OF PAN)BOTTOM 1/4"X3"CONCRETE ANCHORS 2 ROWS STAGGERED 24"O.C' Thomas L. Hanson P.E OR BACK PAN) CONNECTING HEADER OR CHANNEL TO FASCIA ROOF PANEL TO WALL CONNECTION DETAIL 1/4"X 3"LAG SCREWS(2)ROWS STAGGERED 24"O.C. (IF DIRECTLY UNDER SOFFIT) FLORIDA LICENSE:38654 CONNECTING HEADER OR CHANNEL TO FASCIA. ROOF PANEL TO WALL CONNECTION DETAILS SCALE:NTS Myron Max Neal P.E. ROOF PANEL TO FASCIA/HOST BEAM CONNECTION DETAILS SCALE:NTS FLORIDA LICENSE:86663 SCALE:NTS Joel Falardeau P.E. 1/4"0 UPRIGHT FLORIDA LICENSE:70667 Concrete Screw SECONDARY ANGLE MIN Erik Stuart P.E. Column Anchor (SEE NOTES)#12 X 3/4"SMS 0.125"THICK(NOT FLORIDA LICENSE:77605 Size FASTENING SECONDARY REQUIRED FOR 2X3 $ Mi .Spa ANGLE TO COLUMN MEMBER) -7 (TY HINGE LOCATION- FBC Plans&Engineering neerin 2x3 0" EACH SIDE) 2x4 1 3" PRIMARY 2"X2"X 2" / 1/40 x 2"-1 2 MASONRY ANCHOR (B)-3/8"0 CONCRETE SCREW X 0.125"ANGLE / Services,Inc. (2)#12 X 3/4"SMS FASTENING 2"x 2"EXTRUSION- 2"x 2"EXTRUSION / IF WOOD SUBSTITUTE IDENTICAL ANCHOR INTO SECONDARY COLUMN TO PRIMARY ANGLE V • WOOD SCREW OR LAG 6"FROM 6272 Abbott Station Dr.Unit 101 ANGLE(TYP EACH SIDE)(SEE O (TYP EACH SIDE) I / TOP&BOTTOM&@ 24"O.C. Zephyrhills,FL 33542 TABLE) O DOOR 3/8"0 O 1"X 2"BASE MEMBER HINGE LOCATION- / 1"X2"OPEN BACK Ph#(813)788-5314 Concrete Screw (TYP EACH SIDE) Column Anchor ANCHORSPA Fax#1-(866)824-7894 Size B Min.Spa (MIN)(TYP)(SEE TAB&) (1)-3/8"0 CONCRETE SCREW I / E-mail-erb@Ibcplans.com d ANCHOR INTO PRIMARY 2x5 1 ANGLE AND @ 1/4"0 CONCRETE /../� Website-www.IbCplans.com 2x6 1 4" 3"(MIN SCREW ANCHOR @ C.OA.#29054 2x7 1 5 24"O.C.BETWEEN COLUMNS NOTES: (TYP EACH SIDE) 2x9 2 4" 1.NUMBER OFANCHORS"B"IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR HINGE LOCATION 2x1O 2 4.5" INTO THE 1X2. DATE: 03/11/2020 2.MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-3/4"AT AT ALL UPRIGHT 1"X2"OPEN BACK DRAWN BY:ST LOCATIONS.ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED / �® EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. NOTES: - - --- 3.CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON FASTENERS APPROVED ON THE S-1 NOTES PAGE. 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/(3)#10 x 3/4"SMS MINIMUM. (2)#10 x 1-1J2"SMS MIN REVISION: DATE: 4.2X3W/1X2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE w/(2)HINGES MINIMUM. THRU SCREW BOSS OF S.FOR A 2X4 POST:FOLLOW FASTENING DETAIL ABOVE USING(2) 3. HINGES SHALL BE ATTACHED TO DOOR WITH(3)#10 x 3/4"SMS. FASTEN A 1"X2"OPEN BACK RO 1 2"X2"X2"X.125 ANGLE CLIPS ON EACH SIDE.USE(2)#12X3/4"SMS 1"x 2"x 0.044"TO UPRIGHT W/#12 x 1-1/2"SMS @12"O.C.AND WITHIN 3"FROM FASTENING COLUMN TO ANGLE CLIP(TYP @ EACH ANGLE CLIP) END OF THE UPRIGHT. OPEN BACK TO HOST STRUCTURE DETAIL RO 2 (4 TOTAL SCREWS ON EACH SIDE OF POST) SCALE:NTS POST OR SMB CONCRETE BASE CONNECTION RO 3 (NOTE:CONNECTION SHALL BE USED FOR TOP&BOTTOM WHEN APPLICABLE) TYPICAL SCREEN DOOR CONNECTION DETAIL SCALE:NTS RO 4 COLUMN OR POST CONCRETE BASE OR LEDGER CONNECTION SCALE:N.T.S. Jo b#20_0311_192 EXISTING MASONRY OPTION#1 PROJECT ADDRESS: SOLID GROUTED I I NE 1 NE o o @°CONNECTION (4)#1O x 114"SMS OPTION#2 1 GCE INTO SCREW BOSSES 6329 COBBLE BLISS ST 0o ZEPHRYHILLS, FL 33541 1/4"0 X 2-1/2" ___= (1)#S REBAR CONTINUOUS w/25" MASONRY SCREW 3"FROM DVERLAP AT ALL IOINTS ON 3" END&@24"O.C. _____ ____ 2"x_END BEAM CHAIRS (SEE SHEET S-2 FOR SIZE) CONTRACTOR: TYPE II MONOLITHIC SLAB 2"X2"OR 2"X3" 0.0625"ALUMINUM INTERNAL MODERATE SLOPE FTG SLOPE:2":12"-3":12" 2"x 2'x 1/8"x BEAM DEPTH" MEMBER OR EXTERNAL RECEIVING TRUE ALUMINUM CHANNEL W/(4)#10 X 3/4"INTO RECEIVING CHANNEL UPRIGHT OR BEAM NOTES FOR ALL FOUNDATION TYPES: W/(1)1/4"x 3"CONCRETE INTO BEAM OR UPRIGHT.(2) • SNAPORSELF 1"X2"OPEN BACK I IKICU MISTS MATING OR ANCHOR INTO WALL& #lOX 3/4'FA LEG INTO GIRT OR ATTACHED TO ALUMINUM L THE FOUNDATIONS SHOWN ARE BASED R A MINIMUM SOILHOLLOW (4)#10 x 3/4"SMS EACH PURLIN-(0.062"ANGLE CLIPS w/ MEMBER W/(1)#10 BEARING PRESSURE IC 1,500 PSF.THE BEARING CAPACITY OF THE SIDE INTO BEAM 3/4"!24 O.C SOIL VERIFIED BYA LICENSED CONTRACTOR PRIOR TO ANY POURING I I (2)#10X3/4"SMS EA LEG) OF CONCRETE. NOTE:WHEN ATTACHING TO WOOD STRUCTURES,WOOD LAG SCREW • 2.THE SLAB/FOUNDATION MUST BE CLEARED OF ALL DEBRIS,AND ANCHOR DESIGNS SHALL BE OF IDENTICAL SIZE AND EMBEDMENT AS THAT UPRIGHT OR BEAM-SNAP COMPACTED PRIOR TO POURING OF ANY CONCRETE. OF MASONRY ANCHOR SCREWS. R SELF MATING OR KICK PLATE ATTACHED TO ALUMINUM MEMBER DETAILS 3.CONCRETE MEET THE SPECIFICATIONS IN THE S-1 NOTES PAGE. HOLLOW END BEAM TO HOST STRUCTURE DETAIL S- 3 TYPE II MONOLJTHIC SLAB/FOOTING SCALE:NT5 PURLIN OR GIRT TO BEAM OR POST DETAIL SCALE:NTS ALUMINUM RISER PAN-. (4)#10 SMS W/3/4" WHERE ATTACHING TO I ALUMINUM RISER PAN WASHERS PER 12"PANEL USE#10X3/4"SMS2"FR0M 3"X12"RISER PAN PANEL EDGE EDGE& 3"O.C. BEAM IS 1 1 O, /1-1/4"NEOPRENE WASH THE SIZE AS UPRIGHT #12 SMS W/10 NEO-WASHERS (4)#10 SMS W/3/4" PER PANEL J3'X48'COMPOSITE @ 8"O.C.(USE SCREW LENGTH WASHERS PER 12"PANEL #12 SMS W/1"0 NEO-WASHERS #12x4"SMS ROOFPANEL I EQUAL TO COMPOSITE PANEL Detail C2 @ 8"O.C.(USE SCREW LENGTH 1-1/4"NEOPRENE THICKNESS PLUS(1)INCH) EQUAL TO COMPOSITE PANEL WASHER @8"O.C.PER THICKNESS PLUS(1)INCH) SEE DETAIL C2 FOR FASTEN.060 REC.CHAN.TO ALUMINUM RISER PANS Detail C2 BACKSIDE OF 2"XH"EDGE BEAM PI�OFE$$IOIVACeNG}NEER SEAL SEE DETAIL C2 FOR W/(5)#10 SMS W/3/4" ALUMINUM RISER PANS W/(H)#10 SMS W/3/4"ED ENGINEER OF RECORD: INTO SIDE FLANGES : ::::::: : 1"XS"AL 27BE S SHEET S-2 David W. Smith P.E. ® 2X[H) 1'X2'OPBN BATIXA7i'rACHHO SE S-2 FOR OPT[ONAL1"X2"FASTENED ® ® EDGE IZE) FLORIDA LICENSE:53608 (2)-1/4"0 MACHINE TO COLUMN WITH(2)#10 X 2" ® ® BEAM kloXlyF'SM1oxiItSMSSISMo.c BOLTS WITH 314"__/ SMS INTO SCREW BOSSES �� �� (4)#IOX3"INTO Thomas L. Hanson P.E. L f) SCREW Boss FLORIDA LICENSE:38654 WASHERS THROUGH AND FASTENED TO EDGE ®® 9 POST AND EDGE BEAM BEAM WITH(1)#10 X 1-1/2" APPLY EDGE BEAM W/REC.CHANNELS SMS WITHIN 6"OF COLUMN TO NOTCHED POST FASTEN.060 REC.CHAN.TO AND @12"O.C.MAX UNDERSIDE OF 2X_EDGE BEAM Myron Max Neal P.E. W/(4)#10 SMS W/3/4" CONTINUOUS EDGE BEAM POST 2EESHEETCOLUMN/UPRIGHT FLORIDA LICENSE:86663 POST STAGGERED CONTINUOUS EDGE BEAM W/(2)#10 SMS W/3/4" EESHEeeS-z FOR NOTE:EDGE BEAM(SEE SHEET S-2 FOR SIZE)SHALL BE ORIENTED IN DIRECTION SHOWN. INTO SIDE FLANGES I' II SIZE) Joel Falardeau P.E. NOTE:EDGE BEAM(SEE SHEET S-2 FOR SIZE)SHALL BE ORIENTED IN DIRECTION SHOWN. hi i LORIDA LICENSE:70667 ROOF PANEL TO EDGE BEAM CONNECTION DETAIL A REC.CHANNEL.060 MIN.,SAME WIDTH AS BEAM TYP. SCALE:NTS ROOF PANEL TO END BEAM CONNECTION DETAIL A rik Stuart P.E. ROOF PANEL TO EDGE BEAM CONNECTION DETAIL B SCALE:NTS FLORIDA LICENSE:77605 SCALE:NTS FBC Plans&Engineering Services,Inc. 6272 Abbott Station Dr.Unit 101 Zephyrhills,FL 33542 Ph#(813)788-5314 Fax#1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fbcplans.com C.O.A.-#29054 DATE: 03/11/2020 ALUMINUM RISER PAN DRAWN BY:ST (4)#10 SMS W/3/4" REVISION: DATE: WASHERS PER 12"PANEL RO 1 #12 SMS W/1"O NEO-WASHERS @ B"O.C. (USE SCREW LENGH EQUAL TO COMPOSITE RO 2 PANEL THICKNESS PLUS 1") Detail C 2 RO 3 SEE DETAIL C2 FOR COMP,ROOF RO 4 ALUMINUM RISER PANS Job#20 0311192 2xH EDGE BEAM `{ (SEE SHEET S-2 FOR SIZE) PROJECT CT ADDRESS: CO1NE 6329 COBBLE BLISS ST (4)#10X1-1/2,S.M.S. (4)#10X1-1/2"S.M.S. ZEPHRYHILLS, FL 33541 INTO SCREW BOSS INTO SCREW BOSS OPTIONAL 1"X 2"FASTENED TO COLUMN WITH(2)#10 X 2" CONTRACTOR: SMS INTO SCREW BOSSES FASTENED TO ED EBEAM WITH TRUE ALUMINUM 2xH SMB (S)#10 X 1-1/2"SMS WITHIN 6" (SEE SHEET S-2 FOR SIZE) OF COLUMN AND @ 12"O.C.MAX. ROOF PANEL TO SMB POST TO EDGE/END BEAM CONNECTION DETAIL C SCALE:NTS DETAILS S-4