Loading...
HomeMy WebLinkAbout20-22756 CITY OF ZEPHYRHILLS 5335-STH STREET (813)780-0020 22756 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION:INFORMATION. Permit#:22756 Issued: 4/21/2020 Address: 3089 LYTTON HALL DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 225,863.25 Total Fees: 18,769.97 Subdivision: HIDDEN RIVER Amount Paid: 18,769.97 Date Paid: 4/21/2020 Parcel Number: 24-26-21-0110-00000-1520 CONTRACTOR INFORMATION OWNER INFORMATION = Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA, FL 33607-5995 Phone: (813)574-5743 Lic: Phone: (813)574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,005 SQ FT APPLICATION FEES P MBING FEE 175.50 SEWER CONNECTION RES DEN- 2,090.00 ELECTRICAL FEE 263.25 WATER CONNECTION RESIDENT 1,010.00 MECHANICAL FEE 122.85 SCHOOL IMPACT FEE-sfr/1% 83.28 SCHOOL IMPACT FEE-sfr/100% 8,328.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,268.40 PARK FEES SF 769.56 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 WATER METER RES 3/4" 473.78 Inspection Required F OTER 2ND ROUGH PLUMB MIS INSULATION CEIL-ING- FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. '51"tUtWT ATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER j PASCO COUNTY, FLORIDA Det PeOnitted�� 7 2 r Name Control Builder NamelOwne hJGft/Zdf Y t(/m f.$ ' t County Parcel No. z z�r Z 1-D/1l}-0 subDty: dAn Address/location Classiticallon/Type of Usry A-1 �ti' T7Lmr I i TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Zj 605 Exempt ❑Yes ❑No How Datermined I Impact Fee Amount s,302.00 Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single•Famlly Detached House Amount (057) Mobile Home (058) Other Residential 23) Collection Fee ilk Exempt b Yes ❑No How Determined PARKS AND RECREATION FEE Land Account lend Credit Land Total � ' I Recreation Account Recreation Credit ,Recreation Total Zone TOTALAMOUNT $ 7W 56 j Exempt ❑Yes ❑No How Determined LIBRARY FEE Land Account Land Credit Land Total j Faclilly.Account Facility Credit FaclUtyTotal J Exempt ❑Yes ❑No How Determined Total Amcunf ft— I RESOURCEFEE ERU TOTALAMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE ,BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Acknowledgement below doe*not Imply acceptance of concurrence,but*imply receipt ofa copy of thts form,placing the buMn permit owner on noUce of thts assessment and the condition*or payment for some. DATE RECEIVED BY RECEIPT NO. DATE BY Lennar Homes-3089 Lytton Hall Dr:2,005 sqft Column SO. FEET PRICE MAIN OR LIVING: 2,005 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 225,863.25 FEE SHEET $ 1,170.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,268.40 ELECTRICAL: $ 263.25 PLUMBING: $ 175.50 MECHANICAL: $ 122.85 SUB-TOTAL $ 1,830.00 TOTAL $ 1,830.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,957.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 8,328.00 100.0% $ 8,328.00 1.0% $ 83.28 TOTAL: $ 8,411.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,769.97 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received MAR 2 4 2020 Phone Contact for Permitting 813 363 _ 2891 Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 3089 Lytton Hall Drive LOT# 0152 SUBDIVISION Hidden River Phase 2 PARCEL ID# 24-26-21-0110-00000-1520 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR e ADD/ALT 0 SIGN 0 Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR = COMM = OTHER TYPE OF CONSTRUCTION BLOCK = FRAME = STEEL = DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 2005 SQ FOOTAGE 1555 HEIGHT 1 Story' 1"ITI'TrITI'7TITrTnT1"1'T'TI"ITIT7�T1"1"I�PTTIT ITITR9TT1"1"I1T1" BUILDING $ VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE ® PROGRESS ENERGY Q W.R.E.C. r PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS W1 ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES DO -1-1-1-�I--1--1-4-E�1--1-1-f-�1--1--4- H-1--���N-1--�1--1-FI--1-�1--1-1--1-�F-Hal--1-4.1--�1--1--1-1-t-�1--F-1-1--1-� BUILDER COMPANY I Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y!N Address 4600 W.Cypre L Ste.200, ampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE F REGISTERED Y/ N FEE CURREN Address 1034 Skipper ad,Tampa, FL 33613 License# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, ayonet, 34674-5308 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address P.O. Box 5308 ayonet,FL 34674-5308 License# I CAC058062 OTHER COMPANY C Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address 4211 Shoal Li Blvd, Spring Hill, FL 34607 License# CCC057991 111111111111111 111111111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety'Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. .1ititi-oins: Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (AlC upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW Single Family Dwelling Plan Review Comments 1. V.F.E. shall be a inim'mum of 8"above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W.use permit: All 4 sides of driveway thin the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All.property markers shall be uncovered and marked at time of first inspection. 8: All A.D.A.'requirements shall be znet: 9-. No electric,.plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11.Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M 1308:1 14. Return air in all bedrooms. F.B.C. M1620A 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16: All glazing requirements are to be in accordance with R308.4 of the F.&C. 17. All means of egress are to be in accordance with R311 of the F.B.C.. 18. "Green gypsumboard" shall not be used as a backer in showers or tubs. R7o2.4.2 F B.C. 191 Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20.'Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plurilbing,inechariical, and electrical shall be separate from unit to unit: This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. _r y 23. Tamper-Resistant Receptacles in accordance with 406.11 ofthe 2016-N.E:C 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around'the structure. 25: R403.5.3Ho(Waterpipe insulation Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the following: Piping 3/. inch (19'.1 mm) and larger innominal diameter.. Piping serving more than.one dwelling unit. Piping Jocated outside the conditioned space: Piping from the mates heater to a-distribution manifold:, Piping.located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower door test shall be provided before C.O: 26.A copy of the enerjzy carts shall be with permit at all times 27. Copy of final'insulation-report shall be provided ivith perfnit before&nal 28 No fence,pool onscreen enclosure Is issued with:this permit F.F.E.-Finished Floor Elevation RB.C--Florida Building Code 6t'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) 148 FF EL r ;{ r' , r , ,1,0 '° t `• ! �y ~ r Y► r r 7F EL ."'."-.�.,'� .�j \'`�`�- r ' t, 1 \\•��� . 149 � L f { 1j { A +�0 ' �i t"� 2`� j t� � F FFEt `• ���, /yam• / 1 0 4 LtL 267 q rj 1�O FFEI � 1 � � 72:50 r� ~� ��l a(� 1 1. �, : r0� 72.45 f T I ,q 30g � / L, 0 2 2 FFEL rf ra'f � `�i,�\ __ �y _ Et • } + r ;1 pp ` ,� `1 f � L <'`e,+��e.,� Ta.Us ''1 ti�1 FF EL 1 l B �315 266 ! 'r ` .yt-♦ a/$ 5 -'`' .r'' EL 293 2{0 3 ra. F F Et--7 j U ,.. �y ,� �.� ;;�as:,'7•:_�w�s;.;:�;,t:. c��;y' i P i ;`-�-�"�,7r'1C-..,._-. ,+..„� �" f 7 r� �, F L �'``. �.•,,� _ ,,,_ .•-- 1'' lt'. 1� vi�06 294 FF F r : J _ _ { st EL 1 E hZ 74.05 'i t �t �/�� �+► `r` e t 229 FF j f t f � T3.30 A :1 m; !'�1 I Ah A �"��� :"y'x"k3' ": ;�p• � P`� p � � � r--..,,�_- $r i �L Et r ,264 1 " ....'—;-....".r. ...._-.—�' • 'titi �!, '+�; '53 �� a �� I I'`` A 305 1``' FF� 'r ./ , `t �,tn �-^ „ '`p�� •_•. {p j R �4 tri 1``',U' 295 7 3.$s `k 1 1 ~``'' j ��"i j1 230 A ('�` i eS 1 •` Et 1 r r �� t t FF E! \t 3.26 r t tt 7 60 1 .11,54 7$$g � ��� ii �� ,� ~` ..0��� ��'' i .- 1k ''� y+y '��� � A r�' p�y�f �s pF EL � 304`°� 231 7gs0 `r � I`,�r r ,.`4 FEEL � �l, ',S•.i 1� o f w r''�.-".'� ,� i� J�..,,,. f�,.-- 't`. '` x �`�t Y�} '.G�..- !�yar� FF EL "VrG EL Y� j1. 7 �- -. - �1-� - FF EL 3 'tr�.- ,�•!.- , 73.4a'•� � 3.35 r.� r�.,,• �i,r' 23 J2.15 1� +. A r 297 IN FF EL .h i 1 11 .�•^'� 73.15 V41 f rr PLOT PLAN NOT ASBOUNDARYKETCH ONLYSURVEY SEC. 24 , TN/P. 26 S, RNG. 21 E. LOT )52 BEARING BASIS: HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00*23'02" E PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND PRELIMINARY DRAWING* ON LOT AREA CALCULATIONS N NOTES TAKE PREFERENCE. THIS PLAN IS FOR PERMITTING PURPOSES LOT =--Z0—Z971Z--SQ. FT. ALL DATA SHOWN HEREON BASED ON THE ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA FT. o ENGINEERING PLANS OF KIMLEY-HORN AND ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY 40 --SQ. FT. ASSOCIATES, INC., PROVIDED BY LENNAR HOMES. GARAGE 406 --SQ, FT. LEGEND: COVERED LANAI =--N/A--SQ. FT. 10' PUBLIC UTILITY EASEMENT = PROPOSED DRAINAGE FLOW PATIO 23 ---SQ. FT. (00.00) PROPOSED GRADE CONC. DRIVE 458 -SQ. FT. E-00.00 = EXISTING GRADE A/C & CONC PAD =-A---SQ. FT. PRIVATE SIDEWALK =28---SQ. FT. NOTES: IMPERVIOUS = 36--% LOT GRADING TYPE = B =--Z.5-Z-CL—SQ. FT. PROPOSED PAD ELEVATION = N/A SOD 4537 --SQ. FT. FRONT SETBACK = 20' SIDE SETBACK 10' OFF LOT AREA CALCULATIONS REAR SETBACK = 10' RIGHT OF WAY =--683--70--SQ. FT. DRIVE APRON FT. PUBLIC SIDEWALK FT. SOD = 310--SQ, FT. TOTALS AREA = 7740.87 SQ, FT. S 83-47'02"E DRIVEWAY = 602--SQ. FT. 25,00' SIDEWALK =---15-8L—SQ. FT. SOD 4847 __sq. FT. a- LOT 151 L.Li 0 (5 q0, > N 89-50'30" E O�, 110.00' ry R C) o ct: 46.00' .......... ............ ............ Ld 4- p0 a z C14 0 TRACT "B" �EZLA LID ct -L M rn 8.'D. ......�0. HIDDEN RIVER PHASE 014E A C14 31,51' ....I �6 0-0 (PLAT BOOK 74, PAGES 101-121) 0 ............. ........ 0- WETLAND CONSERVATION p I AREA 54'-0" 20.1 136 Lo 4.0 ' ..­ i "** 86!28'09'W ............ 25 0 110.00 S 83*05 491, PLAT LOT 153 BOUNDARY 4 DESCRIPTION: LOT 152, MAP OR PLAT ENTITLED "HIDDEN PROPOSED: RIVER PHASE 2", AS RECORDED IN PLAT BOOK LOWEST FLOOR ELEVATIONS: 079, PAGES 102 THROUGH 110, OF THE LIVING AREA: 72.30' j PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA: 4 ELEVATIONS REFERENCED TO CURVE RADIUS I ARC I CHORD BEARING DELTA NATIONAL GEODETIC VERTICAL 1 54.52' 1 54.49' OE2�28" C253 490.00' 57.68- 1 57.65- 1 S 03-31-51- E 06!44-40" 1 DATUM OF 1929. MEAN SEA C262 1 500.00 70.63- 1 70.59' 1 N 03-31-51- W 06-44'40- 1 LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101CO458F EFFECTIVE DATE: 09/26/2014 Square Feet: 7057.17 t LENNAR HOMES (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, ¢= CENTERUNE, A/C AIR. CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/F= EDGE OF-PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.- MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK,-PCP='PERMANENT-,CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D=--SET NAIL & DISK No.4493, TBM= TEMPORARY BENCHMARK, ULP= UTILITY POLE, W/F= WOOD FENCE Drawn By: JOHN R.BEACH&ASSOCIATES,INC. SMS SURVEYORS AND MAPPERS Checked B t 911 WEST ST. PETERSBURG DRIVE JRB y: ONE OLDSMAR, FLORIDA 34677 Scale: WAY (813) 854-1276 FAX (813) 855-8370 /Zab 5 NOT VALID WITHOUT ORIGINAL SIGNATURE Date: PLOT PLAN 3/17/2020 ACS 5 AND SEAL OF A FLORIDA LICENSED NATD�� JDATE SURVEYOR AND MAPPER JOHN R. BEA 5 Revisions: FLORIDA REG1AND SURVEYOR No. 2984 LB#4493 JEFF M. U&R<EY NAL SURVEYOR & MAPPER No.7123 INSTR4 2020066295 OR BK 1 0090 PG 344 Page 1 of 1 04l2P1202D 11:2D AM Rcpt 2155430 Rao.10.00 DS:ODD IT:D.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller Permit No. Parcel 10 No 24.26-21-0110-00000-1620 NOTICE OF COMMENCEMENT state of Florida -_ _-- County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,end In accordance with Chapter 713,Florida Statutes, the following hdorme0on In provided in thls Notice of Commencement: 1. Dawtpgon of Property:Legal HIDDEN RIVER PHASE 2 PB 711 PGS 102-110 LOT 162 StrestAdamas: 3089 Lvftn Hall Drive zepltiyhilis Ft. SM41 -- 2. General Descipgon of Improvement=Single Family Residence I Pool t Screen Enclosure!Fence 3. Ownerhttommation: Lennar Homes,LLC. N - 46D0'�1VCvpte5Tame Ste200 S m2a FL.33607 Address--"-' -City - - State hnerest in Property: Name of Feo Sknple Tlflaholder.,.NIA - of other than ohlrer) __ _ ey�i ► "��I�` Address Stets N 4. Contractor. Lennar Homes,,LLC . a - � 4600 W C Nary ime s-St,Ste 200 Tampa FL,,33607 Address City state Centraeorti Telephona No.: 813.674.5700 �t 5. swttr..' "NIA to- - • 7nu rvamer S e. Address Gry state • . Amount of Bond:S _ - -- Telephone No.:. - a. L can WA 1887 Name Address -- --- - city - - stele Lander'sTelaphdwNa:- 7. Persons within lha State of Florida designated by the owner upon whom notices or other documents may be served an provided by Section 713.13(1)(a)17),Florida Ststetes t Nanrra L pn2r Hwiies:LLC' tii —L U-j Q U J J r 460resW Cvoress St,Ste.200._ Tampa FL�,33607 ft) i j _ _ r Adds City state LL. Telephone Numberaf Dos%noted Person: 813.574.5700_ ".- c3 0 O Z 0 (1) - N 0_ a. In sddillon to himself,the owner dsetnetes_N/A of 0 ;5 5 -F 1 p ,u L to receive a copy of"Uenors Notice as provided in Section 713.13(1)(b),Florida Statutes. < W to Telepon he Nu of Person or Entity Designated by Owner. - (L OC w ` w `� 4 Q D. Expiration date of Notice al Commanrement le one year from the date of rev rating urdess a different data Is specified: N f WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT F S C> —1 t ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART i, SECnON 713.13, FLORIDA STATUTES, AND CAN t— >- LL, b RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE 0 C6 RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONsuLT � 4 O Ll,) IMTH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. w STATE OF FLORIDA U in LL 0 COUNTY OF PINELS .�,.G.'�.�✓ - - - - � L_ 1 S z G O IA SignsWroof Owner orOwnersAuihortmdOnkerrD1923 .WerlMenagor - fY Q Vice President _ ti ut a p a Signore"7111e/Olfica -4 rJ U cc The foregoing Instrument was edorowiedged before me thin 11 day of March ._ ,by td.O Z 0 Steve Robert Smith. -_ as.maa President gyps ataathomyr,a.,ofltCur,hestee,attonwy M fact}far 0 cn d Lennar Homes LLC LL, w Li (name of pa ore Instrwrrent was executed). Q { =) Personallyi(nown(i 0 Produced identification C) Notary$' a' ��''i^^�- b" _ , � M z Ctl Type of identification Prodoced Name(Pam) Vim Holleran � � � � � Verification pursuant to Section 92M5,Florida Statutes.tinder Penalties of penury,i dedare that I have read the fmagdng and that the fads stated in it are true to the beat of my knowledge and hormf. 11LH011$111N Signature of Natural Person Signing Above Caaa�tteelFFitdd3tT r�flnJunsA ,2lt2g "dolatCerbesform: =2 2t�trrarvat06ai53pII C PASCO COUNTY Receipt Date: 04%1.1%201ti CONSTRUCTIONS ES Re Number 9972686 BUILDING _. SERVICES- Receipt I .. 8731 Citizens:Drive P-A'-*-S-LOTJN'P,Y FI;OA-1 Suite 230 OrFri Sgec6s:[huwinPr PincEs; New Po&,Richey,FL°34654 ,. .._ 727;847-8126. ** NOT A PERMIT '** 'Pald.By, Check# CC.Auth# Cashier,ID Workstation i Chddk 01454965 MLARNOLD BGCCR59W -Fee Description. Arrtount Paid, Impact'Fee:I2esidential Solid'Waste Single Family 32,94 Total Payments: $42.94 Pavor Address Phone LENNAR - Comments:. 2275ti 24-260'40110-0000071520 3089'L'YTTOK HALL DRc while;yo4 will be paying your bill With:Pasco Cdunty:BUllding{onstructlon Services;the full amount of[he credit card ore,-check fees;,Mot shown above;Is collected by First 8411rig payrneh[senilces: - - _ .__ myreports/reports//PASCOPROD/PASCO%Customer Receipt v1f rpt Print Date:, 07/13/2020. Page 1 of 1 09 IEr�§ineerir#g lnsp ction Specialists July 8, 2020 Mr. Bill Burgess, CBO—Building Official City of Zephyrhills Building Department 5335 8th Street Zephyrhills, FL 33542 RE: P.N.—22756 3089 Lytton Hall Dr.Zephyrhills FL 33540 Hidden River Lot 152 Missed Slab Inspection Dear Mr. Burgess; It is our understanding that at the project referenced above the contractor missed the required slab inspection by City of Zephyrhills personnel. On 7/07/20 Lennar Homes requested that LogistX provide a slab inspection verification. Be it known,that a quality assurance inspection,a portion of which encompasses the components to be inspected during the municipality slab inspection, was conducted by a LogistX inspector under my supervision on 6/25/20. Based on the results of this inspection, to the best of my belief and ability, the building components covered by the municipality inspection were completed and installed in conformance with the approved plans and the Florida Building Code, 6th Edition. If you have any questions or require additional information, please feel free to contact me. Respectfully Submitted, This item has been digitally signed and sealed by Paul 'QQ'"� cErvS��F� D.Kidwell,P.E.on the date f adjacent to the seal. No.52683 Paul D. Kidwell, P.E. .*o * * i Printed Copies of this FL Reg#52683 �JO STATE OFP document are not 4 o R,o considered signed and `.��NALE� sealed,and the signature Ref— 20-00823 I AGREE TO THE SPECIFIEDPORTKINSOF THIS DOCUMENT. must be verified on any THIS ELECTRONIC SEAL APPLIES ONLYTO THOSE SHEETS CONTAINING THE ENGINEERS NAME BLOCK.SEALED FOR FOR STRUCTURAL ONLY,NONSTRUCTURAL ITEMS ARE electronic copies. SHOYM FOR ILLUSTRATION AND CLARIFICATION ONLY. 2020.07.13 11:12:15-04'00' BDH Consulting, LLC.d/b/a/LogistX 1-833-LOGISTX(564-4789) P.O.Box 252,Seffner,Florida 33583 Certificate of Authorization-#32424 IS.iZ*46k Er�oirieoe ins,Inspection Speciolists W July 8, 2020 Mr. Bill Burgess, CBO—Building Official City of Zephyrhills Building Department 5335 8th Street Zephyrhills, FL 33542 RE: P.N.—22756 3089 Lytton Hall Dr. Zephyrhills FL 33540 Hidden River Lot 152 Missed Ufer Inspection Dear Mr. Burgess; It is our understanding that at the project referenced above the contractor missed the required ufer inspection by City of Zephyrhills personnel. On 7/07/20 Lennar Homes requested that LogistX provide a ufer inspection verification. Be it known,that a quality assurance inspection, a portion of which encompasses the components to be inspected during the municipality ufer inspection, was conducted by a LogistX inspector under my supervision on 6/25/20. Based on the results of this inspection, to the best of my belief and ability, the building components covered by the municipality inspection were completed and installed in conformance with the approved plans and the Florida Building Code, 6th Edition. If you have any questions or require additional information, please feel free to contact me. Respectfully Submitted, _ This item has been digitally signed and sealed by Paul D.Kidwell,P.E.on f` the date adjacent to the * No.52683 * seal. Printed Copies of this Paul D. Kidwell, P.E. .� * p FL Reg#52683 = J3 STATE OF document are not 4 O RID considered signed and Ref—20-00823 .�ONAL ENG%' sealed,and the signature I AGREE TO THE SPECIFIED PORTIONS OF THIS DOCUMENT. must be verified on any THIS ELECTRONIC SEAL APPLIES ONLY TO THOSE SHEETS CONTAINING THE ENGINEERS NAME BLOCK.SEALED FOR FOR STRUCTURAL ONLY,NONSTRUCTURAL ITEMS ARE electronic copies. SHOWN FOR ILLUSTRATION AND CLARIFICATION ONLY. 2020.07.13 11:13:09-04'00' BDH Consulting,LLC.d/b/a/LogistX 1-833-LOGISTX(564-4789) P.O.Box 252,Seffner,Florida 33583 Certificate of Authorization-#32424