HomeMy WebLinkAbout20-505 Q
F.CUIIIUfI City of Zephyrhills PERMIT NUMBER
5335 Eighth Street
Zephyrhills, FL 33542 BGC-000605-2020
K:`Y� Phone: (813)780-0020
Fax: (813)780-0021 Issue Date: 08/11/2020
Permit Type: Building General (Commercial)
Property Number Street Address
12 26 21 0020 00900 0940 MIS See Description 5530 21 St St
Owner Information - Permit Information Contractor Information
Name: Permit Type:Building General(Commercial) Contractor: DUKE ENERGY
Class of Work:Right of Way Temporary Use
Address: Building Valuation:
Electrical Valuation:
Phone: Mechanical Valuation: �, ✓
Plumbing Valuation:
Total Valuation.$0.00
Total Fees:
Amount Paid:
Date Paid:
Project-Description
MIS SEE DESCRIPTION 5530 21 ST ST/WO 37385168-FEE WAIVE
Application Fees
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit,-there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
WO: 37385168
MOTs: 603, 605
Right of Way Use Permit
CITY OF ZEPHYRHILLS - BUILDING DEPARTMENT
RIGHT-OF-WAY USE PERMIT 7�
DATE: 7/24/2020 PERMIT# �V
No construction under ground or above ground of any facility shall be accomplished on any
City Rights of Way without written approval from the City Building Department. Any application
for approval of construction operations on any City owned Rights of Way shall furnish a detailed
drawing showing the complete scope of the proposed work in triplicate to the office of the
Building Official for approval prior to the commencement of any work. A copy of this permit is to
be kept readily available at the site of the work at all times.
PARCEL I.D. # 12-26-21-0020-00900-0940 CITY
ROAD 5530 21ST STREET,ZEPHYRHILLS, FL 33542
DATE 7/24/2020
LOCATION (Legal Description) :
YINGLINGS ADDITION PB 2 PG 16 LOTS 94 95&96 BLOCK 9&WEST 8 FT OF VACATED ALLEY EAST OF LOTS 94 95&96 PER OR 3556 PG 1389 SUBJECT TO AN EASEMENT FOR UTILITIES OVER SAID 8 FT OF VACATED ALLEY
Permission is hereby granted
to Laurie Jackson Of Duke Energy
4427 Pet Lane ste 101,Lutz FL,33559 Email : coastalpermitting@duke-energy.com
---------------------------------------
for the construction and maintenance of: Phone Number: 13.909_1255
-----------------------------------
Install service to 5530 21st Ave and install)1 pole
i
subject to the following conditions:
i
I
1. The construction and maintenance of'such utility shall not interfere with the property
and rights of a prior occupant.
I
2. All work shall be done in keeping with the standards of the City Streets Department
and under the supervision of the City Building Official, who will be notified at
least one day prior to commencement of construction.
3. All materials and equipment shall be 'subject to inspection by the City Building Official.
I
4. During construction all safety regulations of the Department of Transportation shall be
observed and the City shall be relieved of all responsibility from damage of any
nature arising from this permit. Subject,to the same terms and conditions,
the permit holder may take such safety measures, including placing and display of
caution signs, as it mayl,deem necessary in conduct of construction and
maintenance work hereunder. It is the responsibility of the
permittee to ????
5. All private and all City properly shall be restored to its original condition as far as
practical in the opinion of the City Building Official.
6
6. All underground crossing installation's shall be laid at such depth as may be specified
by the City Building Official.
7. The sketch covering the details of this installation shall be made a part of this permit.
This permit is granted with the understanding that the applicant has notified all
other utility users in the area covered by the permit and takes full
responsibility for any damage incurred by prior installations as a result of his operations
in order that they may safe guard their interests.
I;
8. It is expressly stipulated that this permit is a license for permissive use only and that
the placing of facilities upon ;public property pursuant to this permit shall not
operate to create or to vest any property right in said holder.
I,
9. Whenever the City decides to further'exploit the City Rights of Way, any or all said
poles, wires, pipes, cables, or other facilities and appurtenances authorized
hereunder, shall be immediately removed from said Rights of Way,
or reset or relocated thereon as required by the City Building Official at
the expense of the holder of this permit'
I
I
j
i
10. The holder shall save and keep the City harmless from any and all damages, claims,
or injuries that may occur by reason of the construction, maintenance, and
operation of said facility.
11. The holder shall complete the requested work within days or this permit
shall become null and void. In the event the work requested is not completed
upon the expiration date of this permit, the City shall have the right to
complete such work and to charge the holder of the permit for all costs incurred in
completing said work.
12. The holder shall post a cash or surety bond with the City Manager in the sum
of$ dollars to guarantee performance of the obligations herein,
and to guarantee maintenance of the right-of-way described herein for a
period of one (1) year following completion of the requested installation. In the event a
surety bond is posted, the surety bond shall be made payable to the
City and shall obligate the surety to hold the City harmless in
the event the holder of this permit should fail to meet any of
its obligations hereunder. The bond shall also
indemnify the City for all court costs
and reasonable attorneys fees in the event legal
action is required to collect on said bond.
SUBMITTED BY:
(Permittee) Laurie Jackson Duke Energy
Signature &Title Cea�ri
Address 4427 Pet Lane ste 101, Lutz FL, 33559
APPROVED BY:
CITY OF ZEPHYRHILLS
i
Building Official
Date:
Utilities Supervisor
Date: Af
Public Works
Date:
City Manager
Date: --
USP: BREAKER:C851
Safety Reminders/Adverse Conditions Y
SAFETYFirst �aCte'r1 TRAFFIC AND PEDESTRIAN AWARENESS
p veRsowanccnuNraaurtT �'���yYJ �
p ncme cnr°wc
►wwRORccacenoR �4rE<+
REMEMBER:Work zone area conditions may have changed for this job[Everyone is responsible for verifying the above safety information is correct prior to any work being pertormed each day.
CALL FOR INSPECTION WITH AN 8 HOUR NOTICE AT 813-780-0020-
� Y °kEiM f-•'
Y �� N OXYYYPOq
P1 S!l •°'_
— �1, . waa®n annra sew
FIELD TAG 8629978 1-210-3-SN UG
E - 9X14 AG PED l-2"FLEX TH
P2
E - METER If-#2-3-SN OH
P3
NEW TAG 8702895 _—
I 30/6 ' P1
-- LINE CREW TREE TRIM S YiNGLIN
G AVE
L --..-"
Sl
P.3 _ 1 DUKE ENERGY
Z ON
S2
I, 727 820-4432
P DY
ENGINEERING PARTNER
a 55 Q ---`" LOGAN MIZE
- 813-909-1295
{l} _ 911 ADDRESS: WotXOrd.,Nombef 37385168
5530 21 ST ST c.toroedceotea
-- ` _— -- ZEPHYRHILLS, FL 33542 cmxa N..
S'
JOD SttoAtldmss
553021st Street
cny ZEPHYRHILLS
c«,my PASCO
state,ap _FL,33542
`~~ Deslgcer _CHAD STIVERS
.-It to C5Bl
SCOPE OF WORK: PiIII Yvo, 12.47n.2kV
INSTALL SERVICE TO 5530 21 ST AVE Penns R°y°„v,J Y.IX No_
INSTALL 1 POLE amNtry"o. CITY OF ZEPHYRHILLS
-..- F rt Typedto.2
__- - CONSTRUCTION NOTES: ' i P,,A Tv Ne9
1. ALL ACCESS OPEN Pt
bT 1� �•�DUKE sheet 1 OF 1719/2020
___ _- ENERGY® s-1e 1"=60'
WO#37385168 ITNAVENU£ � N .
F u
aW ,o i
N
BlakB Blak11
R
b 33
EI �+f
72-26-21-0020
YINGLINGS ADDITION TO ZEPNYRHILLS� RWNGLfNCAVENUE 12-28-
PB 2 PG'16 YINGLINGS ADDITP
Blocks 0 P_8.2
P
T i
5530 95 9 12 91 10 09
Biak 10
N
N
1
Po
t -bs
12-ze-2l-aoza
Blot�c3 5 i YINGLINGS ADDITION PTO 2EPMYRMILLS 2
PB 2 PG I6
----- -
UTH AVE ----
zB
68
39
WO#3738EJ .1'2 .-26-21-002A J
I B!ack'4 --Block 7— YJ�GUNOS ADDITION TO ZEPHY
2 -211-0668,
I r
�TICN TO Z��-----.YINGLIIIGS AD[-
1�21`r-116
- - -------- ------ 1121111 123 6
Vill
7TH AVE
�TAVENUE TT H AVE
Tr
BI-kAII I
- -----------I---------
_-----Block®---
J
------------------------:� 7
�J
----------
------------- ---------
-- - -----
10
Block 1
-U�=2021 10 12-26-2i-002A
------------- -------- 112-26 21 T YINGLINGS ADDITION TO ZEPHYRHILLS
PEI 2�G 16
YIN INq.S D.ITI.N TO ZEPHYRHILILS•
- ------------- P.2 P.16
51-5�53@1 0 9-
7TH AVE -------------
96
E,
5
Block 143 -------
Block 1.1
-----------
ps
3 3
YINGLINGS ADDITION TO ZEPHYRNiLLS
12-26-21-002A
-----------
I - I P.2P.1.
-----------
0-\u<
CIO
' L 0#37385168 `
�, ALL POLE _
+' FOR SERVICE
5530 21st STD`
- ___ �.�� ....1.' `I`r,..�_r.•-��ii.�o�.5=,`+'-'f`!1=Y•4'�sys�'Y��.gi..•�r5.� - — v"^s.iY::o--..c...
5T � 1;:�. .w.�L 3�w�:a.'.,'.-r•s�,.."w•n-�.-,.•err -
r. NK=': .c_.c S.C.. "``---. � ,. '�•'�o:�'�=,�___
Zv..i.:.y�4~�''�,�Fe�',-' •'i.� e`ct�.�v 'SS�+:.o, x,s:'rr:�. .��,-. .....;- �`^�Y,ry.^•.
���t; -_L�,;.._.•..+r.s�v.aJ'��tl,.�� .'.�t`'`-"��Yi.'+:i EL�Y��'y::�.«:�;"•:-'.d','�. :_.U��'t' ':�': �„o,:..-.•�.�•� � _�"s;b��- "`��`•�
s :k
4,`�.:.1., .I,-
:fir-•, =��i(�'r.•"3j '•jy ��1 +5VLi��K' rxE-".� -',•�� _ �t++;�-�•r^".G, �-
•Y••r-�> '` h•rf.'�f ';l J•G i��''nyi,�u a��,�����s�a��� _ __ --. _ _ _ _ _ _ "�-_,..>_?.`�:-_
..��=titil'y-.r'c��:Sf'i�?';�.,!� �3'r;�-a: K'^-y.. � ?°t'"� �,E.+�ti•.: y�' '.��,.��._'.` ,,�\�r,. - M•�
- •%'"r.�. .{+r j�fi" „."tc�`fe.' wR:: .��'G^ .-rr�� ytivu.�%`�.!'._�•:'_ - - .`�:.'� :.-{�
�'F-��_`:s-•Nti�.�.���zet+?,.8y: "
Hai A"lYreiri;S`,f'$v�'y..t,�,G-p>••. �yti�='.��K�T ;�yo;�Sz= ''`- ,-.�-., ���•'v +�
"'.t�',£r L�':'1,% e".r'`�'�`?�.a.+'+.—a5) ,.L.r•a.�,�. 7 �a. .eCA`r;.., _E; `` �\. _, ,:�_�:•!,
:+.MST -si„✓;i��.. ,>5;�v+�V'1 'h�`: `�.`.'` ++ '''�= - \
A ,s�w�y.�?{'�y`�'ti+Ly;�-,1��� �,C 't�• -Y-r�r �':'V:-",. •••ti'a t- '.t:` _ � .-� - .\.-T -—_ - •'a
ft x
ix
1%R• .r y�i•.P.�' -L�^�,S.'• f'�'`'•.1-, y.;. '''�'•1 �-.' .i'.{,'t•���,: �:a, f'i'.•''..•r '�'N,'� - - .. `�C - ..
ytf>f"ir:vli�J (.'r.�� ��si�.`?"".a•_'�=c.� •�.., .� '��• '.+.-� ;�1 i_.�-� -�'-'�,�.y, "•�� -
r':%,y-�-n .C�^i�J.F.�.�:�1;�xar ,f�+•'^;':,..Y•....it;V7fi1�C,.� s ( *!,'t "(:.'4.�e,:!� ^t''�' �[:-..:j-,^)'..C:��.�;•i�::-
:'�'r.tea;. 1w•�J,s��T` ,cC. 'Say.>'s/ .ti hti� J�y..,;:_ .,`'�... y-.,,....,_ � �•'`,'''t:)' tn1'''. �(,.•. ,._. _ ._ .Y• ��.:>r.=.��'. '141-,r_x.'-•r':/•�4Y..iS.�=l..i.SLU 1a.J..'1 ,•6_ti_i:_'F.',�'�t..m..1.4�...�:1'_•�
SYMBOLS:
® Work Area
• Channelizing Device(See Index 102-600)
[p Work Zone Sign Buffer
Space 250' C B A
LT' Flogger ee
b Lane Identification+Direction of Traffic Table 1 D
Pogo
�r� vPEv.E1RE➢ ftp,�E VrDPK
n T06tOP AHFAD gHEgO
_-_--__--__----------------------- - -_-____----_-_-________--__--_-____
b rLP LP
Work Area b
PogD Tangent Device Spacing(See Table 1)
1E
WOPK DlIENPE
gxego R,ve<xD PRE
TOsr7 Taper Length
D 50'To 100' x May Be omitted if ROAD WORK AHEAD sign is installed upstream within the project limits.
r
A B C
WITHOUT TEMPORARY RAISED RUMBLE STRIPS
GENERAL NOTES:
].Special Conditions may be required in accordance with these notes 4.When a side intersects the highway within the TTC zone,place TABLE I
and the following sheets: additional TTC de devices in accordance with other applicable TCZ Indexes. DEVICE SPACING
5.The two channelizing devices directly in front of the work area may be Maximum S Distance
A.Railroad Crossings: pacing Maximum Spacing o1
omitted provided vehicles in the work area have high-intensity rotating. Between
a.1f an active length
plus
crossing is located closer to the Wars Area than Posted o/Cones ke Type 1 or Type 11 Buffer
the queue length plus 300 feet,extend the Buffer Space as shown on flashing,oscillatmg,or strobe lights operating. Speed Tubular Markers Barr/codes/Panels/Drums Signs Space
Sheet 3. 6.When Buffer Space cannot be attained due to geometric constraints,use
b.!/the queuing of vehicles across an active railroad crossing cannot be On a On a On a On a
avoided,provide a uniformed traffic control officer or flagger at the the greatest attainable length,not less than 200/t,for posted speeds Ta er Tangent Ta
highway-rall grade crossing to prevent vehicles from stopping within greater than 25 mph. per Tangent
A B C D
the highway-rail grade crossing,even if automatic train warning 25 20' 504 2D 50' 2001 200' 200'[250'
755'
7.ROAD WORK AHEAD andcon iti BE PREPARED TO STOP signs may be omitted if
devices are in place. 30 20' 50' 20' 50' 200' 200' 200' 200'
B.If the Work Area encroaches on the Centerline,use the Layout for all of the following conditions are met:
Temporary Lane Shift to Shoulder on Sheet 3 only if the Existing 35 20' 50, 20' S0' 2001 200' 200' 250'
Paved Shoulder width is sufficient to provide for an 11'lane A.Work operations are 60 minutes or less. 40 20' 50' 20' so, 200' 209 200' 305'
between the Work Area and the Edge o1 Existing Paved Shoulder. B.Speed limit is 45 mph or less.
Reduce the posted speed when appropriate. C.There are no sight obstructions to vehicles approaching the work area for 45 20' 5V 2D 50, 350' 350' 350' 360,
a distance equal to the Buffer Space shown in Table 1. 50 29 50' 20' 100' SOD 500' 500' 425'
2.Temporary Raised Rumble Strips: O.Vehicles in the work area have high-intensity,rotating,flashing,oscillating, 55 2D 50' 20' 100' 264D ISOU ]000 49or strobe lights operating.A Use when both of the following conditions are met concurrently: E.Volume and complexity of the roadway has been considered. 60 2D 50 2D 100, 2640' 1500. 1000, 570'
a. Existing Posted Speed is 55 mph or greater; F.If a railroad crossing is present,vehicles will not queue across rail[racks. 65 20' 50' 20' 100 2640' 1500' IOOO 500'1 645'
b.Work duration is greater than 60 minutes. G.AFADs are not in use.
B.Use a consistent Strip color throughout the work zone. 70 20' 50' 20' 10O' 2640' I500' 1000' 500'1 730'
C.Place each Rumble Strip Set transversely across the lane at locations B.See Index 102-600 for general TCZ requirements and additional information.
shown. 9.Automated Flogger Assistance Devices(AFADs)may be used In accordance
Use Option 1 or Option 2 as shown on Sheet 2.Use only one option with
D. Specifications Section 102,990 and the APL vendor drawings.
throughout work zone.
3.Additional one-way control may be provided by the following means: CONDITIONS
A Flag-carrying vehicle;
WHERE ANY VEHICLE,EQUIPMENT,
B.Official vehicle;
C.Pilot vehicles; WORKERS OR THEIR ACTIVITIES
D.Traffic signals. ENCROACH THE AREA BETWEEN
When flaggers are the sole means o/one-way control,the Ilaggers THE CENTERLINE AND A LINE 2'
OUTSIDE THE EDGE OF TRAVEL WAY.
P, must be in sight of each other or in direct communication at all times.
P,
A
R LAST pJ TWO-LANE, TWO-WAY,
DESCRIPTION: FY 2020-21 IN
SH
EVISION EET
FDOT
11101117 Ww STANDARD PLANS WORK WITHIN THE 'TRAVEL WAY 102-603 1 of 3
D_
SYMBOLS:
® work Area
• Channellzing Device(See Index 101-600) C B A
[]� Work Zone Sign
Flagger
Y.� BE ONE WW<< SLAY RUR00: ROAD
b Lane Identification+DIfPCI1011 Of Traffic � PREPMEO XOA WYOU0. Sm0'S NARK
ro srOP n�+EAn uNE rHEAo AXEAO
Temporary Raised Rumble Strip Set D 250, 250' 250' k
(See GENERAL NOTE 2)
a a
b LP LP LP D
LP
Work Area b
250' 250' 250' D Temporary Raised Rumble Strip Set
(See GENERAL NOTE 2)
ROnD RUHBIE STAY ONEUHE BE
N9RK SrPIDE NY" RND PNF➢MEO
AXFAO /XFAO InlE NR/,p iO SLCP
f
A B C See Sheet I For Layout +Alay Be omitted if ROAD WORK AHEAD sign is installed upstream within the project limits.
WITH TEMPORARY RAISED RUMBLE STRIPS
(When Required See GENERAL NOTE 2)
1 e
vs � ice It,
\e P°\9\149, v —ono ays s ^r SiI�P 2:0, dy 0,Ix .per
Z, aem°`�9jaPe °�ivN 's`r 2a °e°�qe snejoP s`r
\�S�tiP e°� sAa' ded Ene�RoltyPl
rs Ed9�e\ 9rT1, M°\p°\VmSrc\P
\cep
t
J°e\ bo e \0,1e) EdAa e\
/ Ed9e a pipe '(loge
Ed9
/ Ley e\\D�1 e
Q°\et1
/ C0 e\\0Y
REMOVABLE POLYMER STRIPING TAPE MOLDED ENGINEERED POLYMER SET
RUMBLE STRIP SET RUMBLE STRIP SET
OPTION - I OPTION - 2
a
TEMPORARY RAISED RUMBLE STRIPS
a
LAST Z DESCRIPTION:
FOOT FY 2020-21 TWO-LANE INDEX SHEET
REVISION ° —7
TWO-WAY,® iVA�
11101117 w err- STANDARD PLANS WORK WITHIN THE TRAVEL WAY 102-603 2 Of 3
C Taper Length Extended Buffer Space 250' C
Cont.Layout 50'To 100' Do No Cont.Layout
STOP
ON
TgxCitS
-� --- -T i--r-r-r------P9-
�•;Work Areai b
15'Clear(Typ.,Each Side)
R/ •////
R Tracks 50'Tangent Taper r Length
h Device Spacing(See Table 1)
TEMPORARY RAILROAD CROSSING BUFFER SPACE EXTENSION
Shifted Lane(11'Min.)
C Taper Length Buffer Space(See Table 1) Buffer Space(See Table 1) 375' C
cont. 50'To 100' Edge Of Existing Paved Shoulder(Typ) Cont.
Layout � Layout
I
.................. ..................
/ _ _
ork Area
b Edge Of Existing Travel Lane(Typ.)
Taper Lenyth Device Spacing(See Table 1)
Tangent 50'To 100'
TEMPORARY LANE SHIFT TO SHOULDER WHEN
WORK AREA ENCROACHES ON THE CENTERLINE
SPECIAL CONDITIONS
Cross Reference:
1.See General Note 1,Sheet I for more information.
SPECIAL CONDITIONS
LAST JZ�DESCRIPTION: FY 202O-2I F111116EX SHEET
RELAST ° FDOT ��®-II.A1�TE, '7CW0-�.��,
n/ol/v w �- STANDARD PLANS WORK WIIdg3[II1�T THE JCE�iIEE WAY 3 3 of 3
0
ROAD
WORK
AHEAD
2111 200' *400'
CONDITIONS
J \ • l \ / �_ WHERE ANY VEHICLE,EQUIPMENT,WORKERS
OR THEIR ACTIVITIES ENCROACH ON THE
PAVEMENT REQUIRING THE CLOSURE OF ONE
❑ • •• •• TRAFFIC LANE,FOR WORK AREAS LESS THAN
1 • • WOrk Area 200'DOWNSTREAM FROM AN INTERSECTION
2� FOR A PERIOD OF MORE THAN 60 MINUTES.
40d � 20a Less Than
ROAD
WORK ROAD
AHEAD WORK
AHEAD
< <*
200' 400'
t, CONDITIONS
J J � WHERE ANY VEHICLE,EQUIPMENT,WORKERS
OR THEIR ACTIVITIES ENCROACH ON THE
—PAVEMENT-REQUIRING THE CLOSURE OF-ONE--
•--•—•-• --�--- -- • TRAFFIC LANE,FOR WORK AREAS 200'OR
___ _ —b - • • Work Area • /b MORE DOWNSTREAM FROM AN INTERSECTION
I 400' FOR A PERIOD OF MORE THAN 60 MINUTES.
� 50'
200' 200'
ROAD More Than
WORK 200'
AHEAD
DURATION NOTES
SYMBOLS GENERAL NOTES
® Work Area 1.Work operations shall be confined to one travel lane,leaving S.The FLAGGER legend sign may be substituted for the symbol sign. 1.ROAD WORK AHEAD sign may be omitted if all of the following
the opposing travel lane open to traffic. conditions are met:
■ Channelizing Device(See Index 102-600) 6.The maximum spacing between devices shall be no greater than 25.'
2.When vehicles in a parking zone block the line a/sight[o TCZ a.Work operations are 60 minutes or less.
Work Zone Sign signs or when TCZ signs encroach on a normal pedestrian 7.For general TCZ requirements and additional information,refer to b.Speed is 45 mph or less.
walkway,the signs shall be post mounted and located in Index 102-600. c.No sight obstructions to vehicles approaching the work area for
accordance with Index 700-101. a distance of 600 feet.
Flogger B.The two Channelizing devices directly in front and directly at the d.Vehicles in the work area have high-intensity,rotating,
3.If work area is confined to an outside auxiliary lane,the work end of the work area may be omitted provided vehicles in the work flashing,oscillating,or strobe lights operating.
b Lane Identification+Direc(ion of Traffic area shall be barricaded and the FLAGGER signs replaced by area have high-intensity rotating,flashing,oscillating,or strobe e.Volume and complexity of the roadway has been considered.
ROAD WORK AHEAD signs.Flaggers are not required. lights operating.
4.Flaggers shall be in sight of each other or to direct 9.Use Temporary Raised Rumble Strips in accordance with Index
P communication at all times. 102-603.Placement of Rumble Strips and additional signs should
begin at FLAGGER sign location.
a
LAST JZ�
O DESCRIPTION:
REVISION FY 2020-21 INDEX SHEET
FDOT� TWO-LANE, TWO-WAY, WORK NEAR INTERSECTION
II/01/I7 �- STANDARD PLANS
102-605 1 of 1