Loading...
HomeMy WebLinkAbout20-627 m City/ Of ZephyrhillS PERMIT NUMBER F'�OIIIIIN -- 5335 Eighth Street Zephyrhills, FL 33542 FIRE-000627-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 08/27/2020 Permit Type: Fire Property Number Street Address 35 25 21 0010 00700 0000 38011 Pretty Pond Road Owner Information Permit Information Contractor Information Name: SF ZEPHYR COMMONS Permit Type:Fire Contractor:WAYNE AUTOMATIC FIRE OUTPARCEL LP Class of Work:Fire Alarm SPRINKLERS, INC Address: 100-2851 John Markham On UR Building Valuation:$450.00 5CRy7 St Electrical Valuation:(�s�s) Phone: %-1550 Mechanical Valuation: Plumbing Valuation: Total Valuation:$450.00 Total Fees:$2510.00 Amount Paid:$250.00 Date Paid:8/27/2020 4:17:39PM Project Description INSTALLATION 1 DAILER FIRE ALARM-MINIS STORAGE Application Fees Fire Alarm Permit Fee(1-25) $50.00 System Acceptance Inspection $50.00 Fire Alarm System Plan Review $50.00 Fire Alarm Permit Fee(1-25) $100.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. i CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT.CARD FROM WEATHER T)VV kr 9 9 Y 813-780-0020 City of Zephyrhilis Fire Fax-813-780-0021 Permit Application Date Received Phone Contact for Permit .A Owner's Name U es th-g-F Owner's Phone Number Owner's Address F Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address r--n. Job Address POA') Y'd Lot# Sub Division Parcel# F-1 Bio-Hazard Waste Storage-ANNUAL Fumigation Tent F-1 Comm Exhaust Kitchen Hood/Duct F-1 Hazardous Material(Tier 11 or RO Facility)ANNUAL 0 Controlled Bum = Hood Installation F-1 Emergency Generator<30 kw LP/Natural Gas-Installatior Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale Fire Protection Maintenance-ANNUAL a Places of Assembly-ANNUAL fUny rem— An MT—er—1 Recreational Burn Sprinkler M 0 0 0- F Fire Alarm F] 0 0 0 Sparkle' Hood Cleaning 0 11 0, Sprinkler System Installations Hood Suppression E-1 11 0 o El Standpipes(Sprinkler Sys) MR Fire Alarm Installation Torch RoofingfTar Kettle = Fire Pumps Waste Tire Storage ANNUAL HFlammable Application-ANNUAL Valua roject Fuel Tanks Other: )WW P.+I-er- 1^4V Contractor Company #Ire , Signature Registered N Fee Current Y 7 Address IW—b Mr)-%/ iPWIP, 1pr-r-* Q ?*2 4)7-7 License# I a Usgdy 13 I ELECTRICIAN Company Signature Registered I Y/N Fee Current YT—N I Address License# F PLUMBER 7—� Company I Signature Registered Y/N I Fee current Y TN Address License# MECHANICAL company Signature Registered Y/N Fee Current YTN Address LicenS6# OTHER Company Signature Registered Y/N Fee Current L_]L/N Address License Directions: Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement Is required(Mechanical work over$6000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,'they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner', I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR W""`1n e OJ C K � Subscribed andbsworn to(or affirmed)before me this Subscribed and soy or to(or affir e'd)bef 2O Q V1 fWV 2b UA Who is/are personally known to me or has/have produced Vhoo is/are peLaa ally known t e or has/have produced as identification. as identification. Sworn to(or affirmed)and subscribed before me By means of AZI Physical presence or online Notariz Notary Public Notary Public Commission No. Commission No. G� 20.33�z Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped �0. ago^ Notary Public State of Florida Liz A.Colon My Commission GG 203382 Expires04103/2022 \�4��WWYE Automatic Fire Sprinklers;Inc 'Company's Name:Wayne Automatic Fire Sprinklers, Inc. Qualifier Name: Ryan Peterson i License"Number: EF20001320 I hereby authorizeahe City otZepyhrhills to issue permits to Vincent Como,Joe Taylor, Donald Schmidt,James Y., 13gvette, Robert Gant Michael Grant and Greg Dykes.Whose,.positions wifh,my company are Design; Superintendent:,and Permit Coordinator: Check one: i ( )This,authorization is good for the job at: (X)Any and all permits until further notice. The permit,must be signed in front of the'building official or his:representative: I understand that 1 remain fully responsible,for'a11"acfs performed.under said permits. 8/20/2020 Date "License Holder Signature This action must bear the notarized signature•of the licefte.holder**` STATE FLORIDA.OF COUNTY OF'Agi The foregoing instrumentwas,.ackriowied ed before-me this S^� g 9 g t�t day.of 201,by �. .xlSc7Yl ,. (nam of;tli0 person acknowledging) �"o p Notary,Public state of Florida `h Liz;A,Colin y Comrmssion;GG 203382 ;Lap �kpires 04i0312022 Notary Signature t , a irmed)and subscribed"b"efofe me By.means of 7C- Physical presence cir online Notaftation. PersoriallylProfessionaily known -or!Produced Identification Type of ID Produced Regional Office: .3226 Cherry Palm DCIve-Tampa,FL.3360*Phone:(813)6304303 Fax:(813)130.0312 Ocoee Pompano Fort Myers JacksonvUle • Port St. Lucfe Concord, NC ,I I \"N/WANZE Automatic Fire Sprinklers,Inc.® SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval.It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert NlA in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record Form Completion Date: 8/31/2020 Supplemental Pages Attached: -- 1. PROPERTY INFORMATION Name of property: -- C�A e Address: Description of property: -- Name of property representative: -- Address: -- Phone: -- Fax: -- E-mail: -- 2.INSTALLATION, SERVICE,TESTING,AND MONITORING INFORMATION Installation contractor: -- Address: -- Phone: -- Fax: -- E-mail: -- Service organization: -- Address: -- Phone: -- Fax: -- E-mail: -- Testing organization: -- Address: -- Phone: -- Fax: -- E-mail: -- Effective date for test and inspection co tract: -- Monitoring organization: W i G3 Address: -- - J Phone: -- Fax: -- E-mail: -- Account number: YL16 5"Z3�,) Phone line 1: -- Phone line 2: -- Means of transmission: -- Entity to which alarms are retransmitted: -- Phone: -- 3. DOCUMENTATION On-site location of the required record documents and site-specific software: -- 4. DESCRIPTION OF SYSTEM SERVICE This is a: ❑ New system ❑ Modification to existing system Permit number: -- NFPA 72 edition: Year 4.1 Control Unit Manufacturer: -- Model Number: -- 4.2 Software and Firmware Firmware revision number: -- 4.3 AIarm Verification ❑ This system does not incorporate alarm verification. Number of devices subject to alarm verification: -- Alarm verification set for -- seconds State Contractor's#: EF20001320 ZANN E • Automatic Fire Sprinklers,Inc.® SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 ControI Unit 5.1.1 Primary Power Input voltage of control panel: -- Control panel amps: -- Overcurrent protection: Type: -- Amps: -- Branch circuit disconnecting means location: -- Number: -- 5.1.2 Secondary Power Type of secondary power: -- Location,if remote from the plant: -- Calculated capacity of secondary power to drive the system: In standby mode(hours): -- In alarm mode(minutes): -- 5.2 Control Unit ❑ This system does not have power extender panels ❑ Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line -- -- -- -- Device Power -- -- -- -- Initiating Device -- -- -- -- Notification Appliance -- -- -- -- Other(specify): 7. REMOTE ANNUNCIATORS Type Location 8. INITIATING DEVICES Addressable or Alarm or Sensing Type Quantitv Conventional Supervisory Technology Manual Pull Stations -- addressabilit y signal -- Smoke Detectors -- addressability signal -- Duct Smoke Detectors -- addressability signal -- Heat Detectors -- addressability signal -- Gas Detectors -- addressabilit signal -- Waterflow Switches -- addressability signal Tamper Switches -- add.ressability signal -- State Contractor's#: EF20001320 -001; WANN E • Automatic Fire Sprinklers,Inc.® SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible -- -- Visible -- -- Combination Audible and Visible -- -- .10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices -- HVAC Shutdown -- Fire/Smoke Dampers -- Door Unlocking -- Elevator Recall -- Elevator Shunt Trip -- 11. INTERCONNECTED SYSTEMS ❑ This system does not have interconnected systems. ❑ Interconnected systems are listed on supplementary sheet -- 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA/standards cited herein. ��i'� - Printed name: -- �� 1 L%L c--Grl Signed: , Date: $/31/2020 Organization: Wayne Automatic Fire Sprinklers,Inc. Title: -- Phone: -- 12.1 System Operational Test This system as specified herein has been tested according to all NFPA standards cited herein. Signed: Printed name: -- ` �G l Date: 8/31/2020 Organization: Wayne Autfmatic Fire Sprinklers,Inc. Title: -- Phone' -- 12.3 Acceptance Test Date and time of acceptance test: 8/31/2020 10:00 AM Installing contractor representative: Date: Testing contractor representative: Date: Property representative: Date: AHJ representative: Date: I OM State Contractor's#: EF20001320 Oil CUBESMART 38011 PRETTY POND RD. ZEPHYRHILLS, FL L. 33542 SUBMITTAL DATA .A..'.u'W',m Fi :: in:kl: r Ire , 3226 CHERRY PALM DRIVE TAMPA, FLORIDA 33619 PHONE 813-630-0303 -FAX: 813-630-0312 . ''I' �!�p Gor�mercial Fire Alarm Celliular &/or IP CUMMERCIAL FIRE CELLULAR&IP Fire Alarrra G4mrnUnuCatOrS • Universal full event sole&dual path cellular&/or IP commercial UL and NFPA 72 Fire Code-Compliant,the StarLink Series fire alarm reporting from any panel brand,virtually anywhere Wireless Commercial Fire Alarm Sole Path&Dual Path nationwide Communicators provide universal support for any brand • Code-compliant,replaces 2 POTs lines per FRCP saves thousands 12V to 24V fire alarm control panel,reporting in Contact of dollars per year over the leased landlines ID and 4/2. With broadest LTE coverage footprint,Verizon or AT&T,using proven StarLink circuitry,they are also • Supports 12V-24V control panels and FACPs that communicate using available in locking metal models.All provide the most Contact ID and 4/2(such as on legacy panels),as primary or backup economical solution for easy,versatile installation.Also • Full data Reporting to any Central Station nationwide,via choice regional compliances,i.e.,CSFM,NYCFD,LAFD and more. of LTE Networks,Verizon®or AT&T®. Communicate critical life Easy,Universal Installation at Every Application;Panel- and safety alarm reports on LTE(Long Term Evolution)10+year life,cyber-protected multi-billion dollar cellular network,for Powered Technologym.StarLink Fire Communications are maximum life safety&liability protection. easily connected to any panel or Fire Alarm Control Panel (FACP)standardly operating between 12V and 24V.Flexible • Proven to work even where other's won't-using Signal BoostT" in any application,StarLink Fire also comes in standard,or &twin dual diversity antennas- Max.signal acquisition&null models in metal housings,with code-compliant supervision, avoidance(receives signals simultaneously on both antennas) and choice of power options,Panel-Powered Technology" • Easiest installation,powered by panel,NO extra power supply, (powered by the panel),or direct-connect 120VAC models. NO extra conduit.(Excludes Direct AC-Powered "-PS"models,with Signal Boost circuitry&dual diversity antennae for transformer option.)t maximum signal acquisition&null avoidance,receiving • Dual Path Cellular/IP Models Save Time&Money-Uniquely signals simultaneously on both antennae. including 4 programmable EOLR zone inputs;2 Form C Relay outputs Flexible Performance&Reporting Options.StarLink Fire (no extra supervision modules to buy or install);plus,2 Telephone- provides full data reporting,in sole and dual path,as a style jacks for easy FACP-connection.Self-supervised on 4 wires, primary or backup,to any central station of your choice, • Preactivated to ensure communications-saves time and labor onsite without requiring any special equipment on premises. Ultra-affordable plans are available to meet various codes • LED Status/Trouble Indicators 3 Radio Status LED Indicators and requirements,with supervisory check-ins from 200 (visible from outside standard model housing)-Green,Signal seconds,to 5 minutes;and/or from 1 to 6 hours.The units Strength;Amber-Busy/Activation;Red-Trouble(4 additional LEDs, are very easily activated,plans and options are selected, not visible,for network status&troubleshooting).Power LED and 24/7 account management is provided all through indicator viewable on outer metal enclosure models. www.napcocomnet.com. • Over-the-Air Upgradable Communicator Firmware.Remote ability for critical/mandatory updates,without a truck-roll • Cost-saving models and plans for any code requirement. NapcO StarLink Universal Fire Alarm Dramatic savings over monthly dedicated landline charges. Communicators • Sole Path Cellular and Dual Path Cellular&/or IP Models • Choice of LTE Networks,Verizon or AT&T models --—— --- — • Choice of plans(varies by model)-check-ins from 200 - z seconds to 5-minutes,and from 1 hour;up to 6 hours for dual path • Patented Signal Boost"'and Dual Diversity Antennae for maximum signal acquisition&null avoidance,receiving signals simultaneously on both antennae • Money-saving Tradeup incentive credit for security professionals,on new or retrofit fire systems,i.e.,tradeup missing/retired POTS lines,old radios&networks or new installations • Bonus:Full High-Speed Napco Panel remote uploading/ downloading • COMPLIANCES:NFPA 72 Editions:2019,2016,2013,2010, 2007;UL 864,10th Ed.,UL1610,UL985,UL1023,NYCFD; StarUnk CSFM;LAFD ® connected by 1 AT&T verizon,/ NA 0w Code-compliant standard or metal models on choice of Verizon orAT&T LTE networks. a�' �`''' Corr�rnercia:l Fire Alarm Ce,hi:ular &/or IP C®MMERCIAL FIRE CELLULAR&IP Flare Ala'rrn Co'r�'m'u'nic�aitOrs Model Ordering & Specifications veriion' AT&T LTE WIFi Unique Onboard Eledrlcali In Other Power Network Cell IP Option Labor/Cost-Saver Patngsput Inputs Input Ratings Outputs Output Ratings Supply Features (option)t r SOLE PATH SLEATEA-FIRE AT&T Yes No No Panel-PoweredTech'y:tt Input Voltage/Input IN1:9-25VDC Max input OpenCollector0utputsMax PGM7 Current:10V=90mA; INIJA12, current 2mAIN2,IN3: , 3Vwhen active,Max25V 12-25V=71mA, IN3 9.25VDCMaxin ut PGM2, when not active.Max current 200mA peak currentl.2mA PGM3 24mA@25V SLE-LTEV-FIRE Verizon Yes No No P 9 transmissions DUAL PATH 2 TelCo jacks for EZ Panel-PoweredTech'y:n OUTI,OUT2:Dry Contact,Form SLEATEAI-FIRE AT&T Yes Yes Yes FACP Connect;4 IN1:9.25VDC Max InputVoltage:l0-25VDC: C Relay,30VAC/DC,500mA Programmable Input Current:162mA IN1,IN2, input current2mA OUT1, Max PGM3:Open Collector zone inputs;2 Form'C to 100mAst 162 IN3,IN4, IN2,IN3,IN4,IN5: OUT2, Outputs Max 3Vwhen active, Relay outputs(avoids 300mA peak IN5 9-25VDCMaxinput PGM3 Max25Vwhenactive.Max SLE•LTEVI-FIRE Verizon Yes Yes Yes regtforsupervision P g currentl.2mA module transmissions current24mA@25V r SOLE PATH SLE•LTEA•CFB AT&T Yes No No Parnel•PoweredTech'y:tt Input Voltage/Input IN1;9-25VDC Max input Open Collector Outputs Max Current:10V=90mA; IN1,IN2, current 2mA IN2'IN3: PGM1, 3Vwhen active,Max25V 12-25V=71 mA, IN3 9.25VDC Max in ut PGM2' when not active.Max current SLE•LTEV•CFB Verizon Yes No No peak eakduring currentl.2mA PGM3 24mA@25V transmissions SLE-LTEA•CFB•PS AT&T Yes No No Direct AC-Powered:Input IN1:9-25VDC Max input Open Collector Outputs Max Transformer Voltage:120VAC nominal IN1,IN2, current 2mAIN2,IN3: PGM2' 3V when active,Max 25V when (TRF12 Input Current:1 50mA PGM2, max;maximum charging IN3 4.25VDCM.2Ainput PGM3 notactiv24mAe. mum current 16nsform r) SLE-LTEV-CFB•PS Verizon Yes No No current:200mA current 1.2mA 24mA@ 25V transformer) DUAL PATH 2 TelCo jacks for EZ Panel-Powered Tech'y:n OUTI,OUT2:Dry Contact,Form SLE-LTEAI-CFB AT&T Yes Yes Yes FACP Connect;4 IN1:9-25VDC Max InputVoltage:l0-25VDC: C Relay,30VACIDC,SOOmA Programmable EOLR IN1,IN2, input current OUTt, Input Current:162mA Max PGMx3OpenVwh when zone inputs;2 Form C IN3,IN4, IN2,IN3,IN4,IN5: OUT2, Relay outputs(avoids to 100mAstandby; INS 9-25VDC Max input PGM3 Outputs Max 3Vwhen active, SLEATEVI•CFB Verizon Yes Yes Yes regt for supervision 300mApeakduring current l.2mA Max25Vwhenactive.Max module) transmissions current 24mA@ 25V 2 TelCo jacks for EZ OUTI,OUT2:Dry Contact,Form SLE-LTEAI-CFBPS AT&T Yes Yes Yes FACP Connect;4 Direct AC-Powered:Input IN1:9-25VDC Max C Relay,30VAC/DC,500mA Transformer Programmable EOLR Voltage:120VAC nominal IN1,IN2, input current2mA OUT?, Max PGM3:Open Collector (TRF12 zone inputs;2 Form C Input Current:200mA IN3,IN4, IN2,IN3,IN4,IN5: OUT2, Outputs Max 3Vwhen active, 16VAC,20VA Relay outputs(avoids max;maximum charging IN5 9-25VDC Max input PGM3 Max 25V when active.Max transformer) SLE-LTEVI•CFBPS Verizon Yes Yes Yes regt for supervision current:200mA current1.2mA current 24mA@ 25V module) ACCESSORIES: SLE-WIFI-MODULE Optionally connects supported dual path models to FireLink'"Integrated Fire Alarm Control �t.. Internet via WiFi,eliminating Ethernet cable connection.Requires 7AH batty. Panel w/StarLink Fire LTE Built In L .. ("See details WI2191) SLE-ANTEXT75 Optional extended range omni.antenna w/75'cable, I FL-32FACP-LTEV Firewolf 8 Zone 24V Conventional premium low-loss cable&full mounting hardware&ground fault isolation Commercial Fire Alarm Control Panel with onboard mounting plate StarLink Fire"Sole Path,Verizon LTE Cellular SLE-ANTEXT50 As above,with SO'cable Alarm Communicator and Integral menu-driven kkk LCD annunciator,w/4amp,24V power supply. SLE-ANTEXT30 As above,with 30'cable Optionally expandable up to 32 points/zones via commercial addressable,wireless or conventional TRF12 Optional Plug in AC Transformer,16.SV/20VA(use I fire devices(2 onboard NACs providing up is subject to local code compliance)t r' r"_ .., to 4A notification power).Locking metal red 7 enclosure,(surface or flush mount?removable Free Commercial Fire LTE Tradeup Trifold 16"x17"door w/14.25"x16"base.Houses 16Ah Brochures/Moilers/Sruffers(A747) battery backup. StarUnk Firms _ 333 Bayview Ave.,Amityville,NY 11701 • 1-800-645-9445 • www.napcosecurity.com Note:Always consult technical manual and/or AHI for compliance requirements for your area/appiliration.Startnk,StarUnk Fire,Frelink Signal Boost,Panel-Powered Technology,Gemini&Gemini Commercial are trademarks of Napco.AT&T,Verizon,LTE,etc are trademarks of their respective companies.'StarLink offers full data coverage In US from virtually all panel brands reporting in Contact ID or 412.tt For Panel-Powered technology,regulated auxiliary power outputs are required on listed FACP."Add 40mAto input current&Standby Battery requirement.Where permitted by AHI;requires conduit..For full details an the StarLink tradeup incentive see online under hUp://www.napcosecuriry.com/starlinVstarlink4gupgrade/tPromo subject to change w/o prior notice.LTE Idespan claims are based on those of carriers. ©NAPCO,NAPCO Security Technologies Inc.(NASDAQ:NSSq A734A 2019.8 i1 333 Bayview Avenue Amityville,New York 11701 . For Sales and Repairs,(800)845-9445 Starl-ink SLE-LTEV-CFB-PS Fire Alarm Communicator For Technical Service,(600)645-9440 or visit us at httn:lttech.na ncosecuritv.coml O (Note:Technical Service is for security professionals only) Standby Battery Calculations NAPCO Publicly traded on NASDAQ Symbol:NSSC ©NAPCO 2019 W12335LF 4/19 Standby Current Calculations for the model SLE-LTEV-CFB-PS Fire Alarm Communicator: . Standby Battery Capacity:...................................... 7 AH • Standby Current Draw of Communicator:.............85mA • De-rating Factor:......................................................0.80 Standby Time (Hours) = Battery Capacity x 0.80 = _37.6_Hours Communicator Current Draw Examples: 4 AH battery = (4AH / 0.085A) x 0.80 = 37.6 Hours 7 AH battery = (7AH / 0.085A) x 0.80 = 65.9 Hours