Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-635
r- f m FEU i108 City Of Zephyrhills .PERMIT NUM_BER 5335 Eighth Street Zephyrhills, FL 33542 BGR-000635-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 09/14/2020 Permit Type: Building General (Residential) Property Number Street Address 1126 21 0010 17900 0040 5301 17Th Street Owner Information Permit Information` ` Contractor Information. ,.,k•'.. Name: LORI SINGLETON Permit Type:Building General(Residential) Contractor: SIGORA SOLAR Class of Work:Electric Service Replacement/ Address: 5301 17Th St Building Valuation: ZEPHYRHILLS,FL 33542 Electrical Valuation:$84,926.20 9 (/12— O (� Phone: (352)206-3070 Mechanical Valuation: / Plumbing Valuation: Total Valuation:$84,926.20 Total Fees: 6.95 Amount Paid:d:$696.95 Date Paid:9/14/2020 2:54:26PM Project,Description = INSTALLATION ROOF MOUNT SOLAR Application Fees ' - Electrical Plan Review Fee $232.32 Electrical Permit Fee $464.63 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER MON sDaau"Raps Mnd uq A Je4UnOJ JeAO M-s"—YG (e84aoj/AanmS/l0ld)--A ON SOPMOM 03rJOS S—S. sa!Bu!4sAslowou (ptmb-Mn—10 Ate) 'JNIL UNH3d MMMM MU HELM eulBs Bit¢jatpne sumo wog�ilal pazu4ou y�auoaugs e4 PIS+Ge�uw egl.wJ)+�mIM to�d�GotoeA�a4 gal)IUaBV « (80SLS�2�o Sap-Wn ON)'pognbW SI WaW-UDUNw7 Jo OWN 13'OOSZ!"oil pa twm'u6gp!Idde.Jo*mq u81s JOpa4UOO V-tw,0 A1alalduroo uo9— IQde!no IOd muopowle uo!prtq—M3NltelOJP +AROMSALa3dOMd«« '—ld Pei LROt 3lO 919E(Z)LPORV MF MW WJIS emmea=Isew Isnw Sluausmbai lepmumm HV'spa(osd mau IR IPJ Utm,,d voW1eIS"WWMP.L O so- Wed AMIMS 'PaBal_!—d M 1M suMd.raW=uoiS•suetd uolpwmo3'aPsuo Pannhaa.•aleP I4IuWns iMp S&P fWW1-(04)u4 wn=- p •UU!pngsuoa Meu AOl v—d M-O-a-sad Adou310 W 4):abed AIePS OM a sold sueld&Jippn8)o SW elap4—(Z)M99V W M3W VM spap)d GdwV)o.gm.Pgns A18ULed WWVA M!japduAv IL'S SaBg-. d AJIMUeS 'palM"aoua j IL?S/M suRid JM—O)S'sueld UOlpn4suo0'ellsUo PBdP*OU'alBP lW tMns ale S&P BuPNoa!(OI)um wnw-am 'Uoq—lsu--u JC4 W-d M-0-8:sunny AUOU)n 1es W:s'ueld 8uggm810 Slay(Z)xuMd PM(Z)g-6IIV:. IVUN301S3M I airs a'I swiss Isttoso1-tillttsa atilt asawasts%witgas Isla 1:s:ssslts two lilts sil FNtA71 sauna 3%� N/A a3a3Lsio3a 3MN VNDIS ANVdWOO M3HSO SSWPPV N/A bEILWO3AA N/A a3a1slo3a 3MIILVNJIS ANVdWOO �OPiVFiO3W #esumn. SmPPV N/A KMAM 333 r N/A 1 ®a3lsi t 3Mn1VN�14 ANVdWOO y� a38WnId SOOBQl lO3 0 asuaor7 1. Y'^ ./!1,• �� �� sOJPPV N/A Nmrdr1033d' N—IT a3a3iswaa 7' 3mmyNois o-n,- S em81S ANVdW00 NMIORLLO3l3 #fin —PPV FEED N/A cT;a31s03M 3an1VN°JIS ANVdWOO 2130"IlnB Nij oN s3AQ V3W 3NOZ A.-rors3ds p oN! a 0 oudn3�3aooSVD= NOLLvnV1sm IV3INVH63W AO NOl1VnWA S IVOINVH03WQ g SNn3Wnld0 O3M'M 0 ASM3N3SS3MSOad Q 3DYW39dPM OZ'e Z" S 79JM3313Fxx NOLLOIIMLSNOO W.LOi y0'NOILVnIVA 00'OW" 3 SNI4IInaQ �.y-y„t:2 t s t ti s s s s s ems.�.3,>,s i s3�v-•►s s s,a.3i,a a•�•t Y3c.7Y4331 iX3331. IHI iaH =3OVLOOy Rs SMS ONlovne :NIH OZ51I pe!IPiO salnpow Palunow looa 9i )IMOAII d0 NOMMAOS30 mcio1s 0 NOUOM'SNOO d0 3dAL 114410 Q vmoo 0 IHS C] 3Sn®SOdoMd MIVd3 II .HsnOW30 Q Q NSIS p LT MY 8 a15NO3 MVLSNI 3N a 03SOdOad NaOM (30mm KVL ALbmwvd Vwud 43MVIRD) ovoo ooat�oloo-ez -�I #al l3Oavd Nommains sir #101 zvsEe`ty`s►LaPAg CIsgiL�10E5 ss3aaav80! —PPV-Plogel8l eP1wlS eal AequmN euogd saw-p evvaN�PIogSRLI eMwIS�d Je9UMN O wgd raUMO SSWPPV 91mno Z►SEE'ly'61RWAgdS73S gILL.I06S -wqumN'euogd JOUMO uolalBu PoI etueN SAauMO. OL�90Z�ZS£ ' e£BL — OLZ "IEY 6ullyuuedmJixwoJgd PaeWo.?MO0 ol luawyeda0 BUq>L�8 �zoobaL e►e xe� Uo!i»!ldcI+d I! ad sil!UJANdaZ do 4o ozao dgrela 813-780m20 City of ZephyfitNs Pernriit.Application Fax034110-43021 Building Department Nov=OF DEED REs'r anoNS The urvierptgned understands that this pemdtmaq be subject to deed'resb1cbcns'.vhfth may bemore eeshkthre !tram Courtly regulations:The u ndardtinad assumes resporsifrrlibr for compliance with any aypitcable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPON5IBILITiF&:'if the owner has hired s CantmCbor or a ontractors to undedafca work,they may be required to be licensed In a mmla ms with state and local'teyrWons.If the mrdra"is not Hoensed asretgatrad bylaw,both the owner and contradw may be cited foramisdemeffir tolation understate taw.lflhemxmor Intended contractorareuncertainastowhatfrersbrgrequRemerds may apply for the intended work they are advised to contactthe Pasco Carty Building inspection Vl isioit�tir ertsi"Section at 727-847-W09. Furthermore,dfha owner has hired a contractor or cw4nictors,he Is advised to have the contractoiftsign,portions of qrs`contractor BlotW ofthis application for watch they W be respor s-ML it you,as the.ownar slgn as the contractor.'that may bean Ndiaation that heisrrat property lloonsed and is not entdted to penmt1i privileges in Pasco County. TRANSPORTATION-IMPACT/UTILI LIES PAPACT AND RESOURCE RECOVERY FEES:The undersigned understands' chat Trairsporta8an pnpar#Feels and Rsearme Recovdry mete apply to the carstaxtIon of new but! 9,change of use-in edsft buHdhngs,or w4tarrslort ofexSslirhg Iwikkings,as spebcfred in.Persco.Coedhly Chtrutanca mambes88 QT and 9D 07.as amartdod The onderslgned aiso undatstards tttst such tees.es mi3y badue vii9 5A idefntifiad at!fie time cd pairalGng.k is turibet.randorstood dratTrarsportatkin impact Fees and Resource Recovery Foos,,vest be paid prior tit receiving a'ceftitita3te ofoaxq►mnear arflrat powrtr releaser U Ube project does not involve a certificate or occupancy or final povear release,the fees must be paidpnor to permit issueroe.Furtherrrnare,if Pasco Courtly Waterl"aew er impactiedsse due,'they mustbo paid prior to pemhhR tssuanae to aoa with apptk�bie Pasco Courtly ardknaces. - COPSSTRUCiION L1EN i AW(Chaptsr Ti9,Fte»tds St46vtas,as aneandcd):tfvafuatian of work is$2,500.00 or mom I cedffy time 1.the applicant, tbave 4ehen provtded.wih a copy aF iha.'Fiotida Ctinstrrbcticvh LienLaw-HahmowneYs Prateotton Guide prepared by the.Florida Oeparhnent of Agrlctdture arnd Coriscstter Aftaits.HOhe'appiinarht Is saneorne trdter guar rice"oaA>eP,l oer6ry that.I ban obtalreed a copy ofthe above described 7,c,,O,7- ppendR t3a ccunds and that all wrork will be done in Carlo e'aeth lawsmade b obta ina permit to do wok and installation es rtify d RW ai work will ire performed to meet standards of all gregulatlons in thejurjsdiC6orn.l also oartifjt that I caidertand that the regulations atothen 9wemhmert agettoies may apply to the krtmtded work and-that it is my responsibililyto werd+Tyv ud actions I must take to be in oompliahce Suchendts itrdude but are not itmftebd to Department of Environmental Protection-Cypress Bayheads,Welland Areas and Environmentally Sensitive Lands,WaterlWastewraferTreatment. Southwest Florida Water Management District wells, Cypress Bayheads. Welland Areas; Altering Watercourses: - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative SiervioestEnvironrnental Health Unit-Wells;Wastawater Treatment, SeptlldT'anks. US Environmental ProtettiottAgency-Asbestos abatement. Federal Aviation Autliortly-Runways. I understand that the fcim.M resbipions epply tothe use of511: Use of fill is tmt.allowed in Flood.Zone:"V'unless expressly permitted. If the.fill material is to be used in Flood Zone A, it is understood that a drainage plan addressing a "e+ompensating volume"will be submitted at time of permitting which is,prepared by a professional engineer licensed by the State of Florida. If the fill material,is to.be used in Rood Zone.A7 in connection,with a permitted building using stem wall Construction,i certify that All will be Used only to fill the area within the stem wall. If fill material Is to be used.in any area, I certify that-use of such fill'will not adversely. adfect adjacent properties:if use of fill is found to adversely atfeet-adjacent.properties;tlme-owner may be-cited for.vjolatlrlg -the conditions of the building petmit'issued raider the attached'permit application,for lots less than one(1) acre which are elevated by fill.-an-engineered drainage.plan Is required. tf i am the AGENT FOR THE OWNER,i promise in goof faith to irdonn the owrneaof the.permitting cwftcns sen forth in this affidavit prior to commencing construction.r understand that a separate permit maybe required for electrical work;ptumbintk signs,weils.pods,air condiftft,gas.or other trstallations not specltkwAy included in the application.A permit Issued.shad be construed to be a kcerse.to proceed with.the work and not as authority,to Violate;cancel,alter,or set aside any provisions cf tha tech nicalcodes,norshail issuance of a parmhit pnsverd the'BdNfmg Official from thereafter requiring a correction al eirars in plans.constructlorr or violations-of arty codes.Every pt'mut Issued shalt become invalid unless the work autl abed by such petmg is cmnmenaed witidn surmmths of pe ark b3uance,or if work eunwdzed by the pemd!is suspendedorabarkloped for a period of sbc(6)months after the time the wanit is eomritenced_An a tensiommay be requested.in waiting.from the 13nildbng OtWcial for a perod MID exceed ninety(90 days endwill demonstrate justdiable cram for the extenskm.It worts ceases for ninety(90).eonsecutho days.the jab is considered abandoned. WARNING TO OWNER:,YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY-RESULT IN YOUR PAYINIG TWICE FOR 1NlPRi?5►EiMIEl1TS TO YOUR PROPERLY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOLK'LENDER OR AN ATTORNEY BEFORRECORDING Y fR NOTICE OF GQWENCEIAEMM FLORMAJURAT(F.S.117.03) OWNER OR AGENT tdN!RAC " Subsctibet andswant to(or airumed):belbre we this Is rt by eel) meQsy, Who lsrare,pexswmly knmm to me orthsslhave prod=W �Parsdnall !tonne wb p-Utced as identifkallon. as ldentitication. i Nobuy Public i j�}t w.'7 Notary Public commission No Nor I""I 4 0 lneKtry � F�to tanam e 01461sly type%primed ea stamped t tonne of Notary W00.pmed arstanwed SHERRY A FINCHAM NOTARY PUBLIC REG.#142670 COMMONWEALTH OF VIRGINIA MY COMMISSION EXPIRES 05131/2024 ti� 04STR#2020136356 OR BK 10160 PG 3330 Page 1 of 1 08/20/2020 08:25 AM Rcpt:2195211 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller Permit No. 1126210010179000040 NOTICE OF COMMENCEMENT Staleol Florida County or Aasoo THE UNDERSIGNED hereby gales notice that brrprovement wN be made to catdn rest property,and in accordance With Chapter 713.Flalda Statutes, the following trdomation is provided In INS Notice of Commencement 1. Desaiption of Ftopedty.Parcel Identification No.11 26 210010 17800 0040/ CITY OF ZEPHYR)ULLS PB 1 PG 54 LOTS 4 a 6 BLOCK!79 StrestAddress: 6301 17TH STREET,ZEPPHYRHLLS,FL,33S42 2. GmeralDesaip6al0(Impr0yVnmf IIIsla9allmotSdar/ur4 3. Omer Information or Lessee Information Y the Lessee conaaaed for that improvement: Led Similelon Name 53131 17TH CTTtEET W=PHYRHILLS, FL Address City Stele Interestin Property. Named Fee Smrt4e Tmehddc QfdMarenlfrom 0v 115tod above) Add— SiOaa Solar LLC city State 4. Contractor. Name Po box 7543 ChadoOesville VA Address City Stele Contractors Telephone Na' 434 47 0-793 9 5. Surety. Name Address Coy State Amount of Bond:9 Telephone No.: 6. Lender. Name Address city Stte Lender's Telephone No.: 7. Persons within the Site 01 Flalda designated by the owner Upon vfiom notlom or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Standen Name Add a city Stale Telephone Number of Dangnmed Person: S. In addition to himself,the owner designates of_ to receive a ropy ofthe Lienors Notice as provided In Section 713.13(1)(b),Fluids Staadss Telephone Number of Person or Entity DesiWaued by Owner. 9• Explra0on data of Notice of Commencement(the expim6m date may not be before the completion of construction en6lnal payment to the contractor,but will beoneyearfran the date offecording unless a different data is specfied): August 19,2$�l1 WARNING TO OVW* :ANY PAYMENTS MADE BY THE OMER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ESULT IN YO RPAMNG TWOS PAYMENTS IMPROVEMENTS TODFR TpYOUR 713.PART I PROPLILTY-A NOTICE'OF COMMENCEMENT MMUUSTBEBE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT VMW YOIIR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of p0uiy,1 dedare that I have read the fanVoing nodes ofmmmencement and that the fads slated therein are true to the beat afmylmnafedge and bathe(. STATEOFFLORIDA ryry� yt-_ COUNTY OF PASCO r[—JL/v {6- gmamreof0weeror s, Owner's or Lessee's Auhafted Omeanoireclor/Pattrter/Menage llvrc'�a�ltc�f L.� signatory's ipee T1re(aegohlg tmgtmientw+as admoWe``t\ige__d__before me tide• 1 day of 2020 by � G' as 1L]CY''p CL.rfbe` _ (type of authority,e.g.,of er.busies.attomeyin fac9 for !`.�te�sea_�01ar � (mane any m behalf of WJIp shunmil vas exeade�. (/ L Person _ c � py Notary SlgnaMe ' �— Type Zen /�—a Nama(Pdrd) L� 1 ''4a REGINA W(LLIAM$ .1Stete of Florida-Notary PUDIiC Comm)eslon M C 3 276980 My COmm165)on Expires wpdabdbevnotice mmmcemmt pco53049 NOVOMbBf 13,2022 August 25,2020 Re:.Authorization for Permit Pick up To Whom It May'Concern, Please.let thisletter.serve as authorization from Sigora Solar LLC to allow tne'following people�to pick up permits on our behalf. Feel free to contact Anjelle Authement anielle.authement@sigorasolar.com or Holly Davis holly.davis sigotasolar.com Frantz Ostmann Best; i 3oagoo5 Po Box 7543 Charlottesville,VA,229.06 www..tigora$olar.com State of Mr inia County of.Orange The aforementioned signatures were Subscribed and Sworn to before me this 25.day of August 2020 by: Matthew Doran, Manager Electrical.Proc. of Sigora Solar. Produced Virginia Drivers License as identification. o i na rry A. Fincham #142670 y Commission Expires: May 31, 2024 SHERRY A FINCHAM NOTARY PUBLIC REG.*142670 COMMONWEALTH OF VIRGINIA MY COMMISSION EXPIRES 05/3112024 Notary Stamp (seal) 9; ziz- WCONS Wyssling Consulting • _ 76 North Meadowbrook Drive Alpine, UT 84004 Scott E. Wyssling, PE, PP, CME office (201) 874-3483 swyssling@wyssiingconsuiting.com August 13,2020 Scott`� Digitally signed to .L= E Wyssl ng Jon Kirchner,VP of Technology T` � ,-DN:CAUS,S=Utah,L=Alpine,O=Wyssling Consulting, { rRCN=ScottEWyssling+E=swyssling®wysslingconsulting.00m Sigora Solar 1 Reason:l am the author of this document 1222 Harris Street ` Location:your signing location here Date:202D-Charlottesville, VA 22903 W yss l i n g j-6kit,PhimttoOmPDF Verson:10.0.0 Re: Engineering Services Singleton Residence 5301 17th Street, Zephyrhills FL 11.520 kW System Size Dear Mr. Kirchner: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Sigora Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels.. This information was prepared by Sigora Solar and will be utilized for approval and construction of the proposed system. 3. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2 x 6 dimensional lumber at 24" on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Doug-Fir #2 or better with standard construction components. The existing roofing material consists of composite asphalt shingles. Photos of the dwelling also indicate that there is a permanent foundation. A. Loading Criteria Used e 140 MPH wind loading based on ASCE 7-10 Exposure Category"Brr at a slope of 15 degrees e 7 PSF= Dead Load roofing/framing Live Load=20 PSF Snow Load= 0 PSF e 3 PSF Dead Load solar panels/mounting hardware Total Dead Load=10 PSF The above values are within acceptable limits of recognized industry standards for similar structures in accordance with the FBC 2017. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 B. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent"Everest Installation Manual", which can be found on the Everest website (https:Heverest-solarsystems.com/). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Doug-Fir #2 assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/z", is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 V with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, 'condition of roof, the panel supports shall be placed no greater than 48"o/c. 4. Panel supports connections shall be staggered to distribute load to adjacent Rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the FBC 2017,current industry and standards,and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. AVVetruly yours, V.Wysslin Florida License o. 8 nos PLAN HAS BEEN ELEOTROMCALLY SGNMAND ,,�,11�11111111f 1/J���� S&LLm BY SCO7T WYSSUNG,PE USIIIG A DIGITAL SIGNATURE AND DATE PLRV1 D CORES GF THIS \\ t G• V S� //// DOCULVITARE NOT CONSIDERED SGNM AND EA \\._,� _...• / + SLED AND THE SIGNATURE MUST BE VERFIED �� ' // ON AINY ELECTRONIC CORES ` ••�y1 _ / ` 8 r TATE OF �/�owe ' •. ..•.• . , ,� ////���11Jr1,1 JI1111►�\,1\1, CONSULTING I PROJECT DESCRIPTION: APPLICABLE CODES&STANDARDS PROJECT SITE `" 1 : FBC FBC 2017 36 x SILFAB SOLAR: SIL-320 BL 320W MONO MODULES NEC 2017 ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES DC SYSTEM SIZE: 11.520kW DC DESIGN SPECIFICATION W N vi OCCUPANCY: II AC SYSTEM SIZE: 8.640kW AC CONSTRUCTION: SINGLE-FAMILY g o EQUIPMENT SUMMARY ZONING: RESIDENTIAL 36 SILFAB SOLAR: SIL-320 BL 320W MONO MODULES GROUND SNOW LOAD: REFER STRUCTURAL LETTER c/) a F w 36 ENPHASE IQ7-60-2-US MICRO INVERTERS WIND EXPOSURE: REFER STRUCTURAL LETTER , o o ROOF ARRAY AREA#1:-146.40 SQ FT. WIND SPEED: REFER STRUCTURAL LETTER J ROOF#2 a= ROOF ARRAY AREA#2:-54.90 SQ FT. ROOF ARRAY AREA#3:-73.20 SQ FT. (3)SILFAB SOLAR: SIL-320 BL 320W ROOF ARRAY AREA#4:-201.30 SQ FT. MONO MODULES WITH ENPHASE ROOF ARRAY AREA#5:-128.10 SQ FT. IQ7-60-2-US MICRO INVERTERS - ROOF ARRAY AREA#6:-54.90 SQ FT. - ROOF#1 , REVISIONS (8)SILFAB SOLAR:SIL-320 BL 320W DESCRIPTION DATE REV AUTHORITIES HAVING JURISDICTION MONO MODULES WITH ENPHASE - ROOF#6 y INITIAL 08/1312020 BUILDING:ZEPHYRHILLS,CITY OF(FL} (3)SILFAB SOLAR: SIL-320 BL 320W IQ7-60-2-US MICRO INVERTERS ZONING:ZEPHYRHILLS, CITY OF(FL) MONO MODULES WITH ENPHASE SI" r t �•s ROOF#3 IQ7-60-2-US MICRO INVERTERS c. x (4)SILFAB SOLAR: SIL-320 BL 320W MONO MODULES WITH ENPHASE IQ7 60-2-US MICRO INVERTERS - --- 2 HOUSE PHOTO (E)DETACHED - (E)FENCE(TYP.) STRUCTURE - 3 PV-1 SCALE:NTS GATE(TYP.) l • PROPERTY LINE -� i PROJECT SITE w,Y _______________ r Z W 1 `� �✓ I • DATE:08/13/2020 PROJECT NAME&ADDRESS O w ' 1-STORY a ! a HOUSE 0 l } I Y m aI I , irc . z l to i O t.n,ry.ha. O M > I nee "1 W co Msv (E)SHED z u' (� W J ' I va-, Ee. SMNn ' I 5 E5T (E)POOL I I N 0 N j 3 VICINITY MAP r PV-1 SCALE:NTS SHEET INDEX ALL WORK_ DRAWN BY ' } ` �, SHALL ii - - --- --- -- I COMPLY I '�_ - _-_ -_ -__ �� PV-1 PLOT PLAN WITH RO E 'FLORIDA EUiLDING PROPERTY LINE ` 140.01 PV-2 ROOF PLAN&MODUNI $fON,gL ELECTRIC CODE SHEET NAME (E)TREES - (E)MAIN SERVICE PANEL .J� �� PV-2A CIRCUIT LAYOUT AND THE CITY OF ZEPHYRHII + LOT PLAN WITH PV-3 ATTACHMENT DET ((�� (INSIDE HOUSE) ��� �- PV-4 ELECTRICAL LINE DIAGRAIVI�CES ROOF PLAN ROOF#4 '�� (11)SILFAB SOLAR: SIL-320 BL 320W \���� I�WVS�' i,,. PV-6 MICRO INVERTER CHART SHEET SIZE PV-5 PLACARD MONO MODULES WITH ENPHASE .�� � •• SN'• PV-7+ EQUIPMENT SPECIFICAT IEW ANSI B IQ7-60-2-US MICRO INVERTERS ROOF#5 - �� ClT DATE� P (7)SILFAB SOLAR: SIL-320 BL 320W p�N �PHYRHI �� X 1711 MONO MODULES WITH ENPHASE -RS PLAINWISBEENELECTRONICALLYSIGNEDAM PLOT PLAN WITH ROOF PLAN SEALEDBYSCOTTWE. PRI TEDCO IESOFTHISNG A 7ATEOF EXAMINER SHEET NUMBER IQ7-60-2-US MICRO INVERTERS slcw�TUREnNODATE. PRIrrrEDcoPIEsoFTrils f q'•. ,cLOR`OP 1� DOCUMENT ARE NOT CONSIDERED SIGNED AND . Op ••.... .., � PV-1 SCALE: 1/16"=1'-0" _ON�ANYY r.EC RONICr'A MUST BE VERIFIED '7SIONM. " PV-1 " MODULE TYPE. DIMENSIONS & WEIGHT N ROOF DESCRIPTION NUMBER OF MODULES=36 MODULES MODULE TYPE SILFAB SOLAR: SIL-320 BL 320W MONO MODULES ROOF TYPE COMPOSITE SHINGLE = MODULE WEIGHT=40.10 LBS/18.2KG. ROOF LAYER 1 LAYER ROOF#3 O F N MODULE DIMENSIONS=66.9"x 39.4"= 18.30 SFO _mow ROOF RAFTER RAFTER (4)SILFAB SOLAR: SIL-320 BL 320W ROOF AZIMUTH ..�„ - (N)SOLADECK(TYP.) MONO MODULES WITH ENPHASE PITCH SIZE SPACING a u w (N)3/4"EMT/LFMC CONDUIT IQ7-60-2-US MICRO INVERTERS ,* o ROOF#2 ROOF#2 ire ) #1 15° 180° 2X6 24" � a <1 PITCH-15° (3)SILFAB SOLAR: SIL-320 BL 320W ROOF#3 #4 THIS PLAN HAS BEENELECTRONICAUYSIGNEDANC N,AZIM.-270° MONO MODULES WITH ENPHASE PITCH-15° ROOF #2 15° 270° 2X6 24" 0 (11)SILFAB SOLAR: SIL-320 BL 320W SIGNATURE DATE��DCO COPIES IQ7-60-2-US MICRO INVERTERS AZIM. 0° #3 15° 0° 2X6 24' MONO MODULES WITH ENPHASE DOCUMENT ARE NOTCON.4�EREOSIGPEDAND 48'-0" IQ7-60-2-US MICRO INVERTERS ONANYYEELEECTROi COQ SESE REVISIONS #4 15° 270° 2X6 24" DESCRIPTION DATE REV 131-311 INITIAL 06/13/2020 I + #5 15° 180° 2X6 24" I I I `,\``uluiulullq�� I I I I I ` I I I I i I I I I I iii -I---►--7 --I---I_ SD - i i I I I ! `�����E.•V11YSs�`�����i R #6 15° 90° 2X6 24„ I I •. 2 ARRAY AREA& ROOF AREA CALC'S IIi - _ -- SD Fs� i aA7E O #OF ROOFARRAY ROOF AREA� ROOF AREA AREA COVERED — — �9c36"FIRE SETBACK qs flONA�+�`' ,�O` MODULES (Sq.Ft.) (Sq.Ft.) BY ARRAY N I 36"FIRE SETBACK #1 8 146.40 361.76 40 I #2 3 54.90 119.86 46 1 I �5'���Q I SD #3 4 73.20 415.48 18 DATE:08/13/2020 I I F #4 11 201.30 420.92 48 PROJECT NAME&ADDRESS I I -- - PG � #5 7 128.100 314.09 41 ` i I- I MSI' - - - 25'-511 cB ACD --- - - rn ^��`Q- - I - _ #6 3 54.90 153.82 36 z --- m -- `-�' - 39.4',J O W M - -: - (0' _ N O -� (114)EVERFLASH XP COMP W I J z 2 ATTACHMENTS ROOF#1 > - - ROOF#6 N d) C7 W F- J z (36)ENPHASE IQ7-60-2-US - PITCH-15° _ - PITCH 15° i (p - - - AZIM.-180° AZIM.-90° (n (n = MICRO INVERTERS _ O _ — _ Lo (N)EVEREST CROSSRAIL 44-X (N)COMBINER BOX J N r. - - ��� --I SDI-- SILFAB SOLAR: _ N ROOF#1 SIL-320 BL 320W (8)SILFAB SOLAR: SIL-320 BL 320W - --- � 4 MONO MODULES MONO MODULES WITH ENPHASE �� I I I I I LEGEND I %p IQ7-60-2-US MICRO INVERTERS — I I ] I sFr� ROOF#5 SD -SOLADECK DRAWN BY (E)MAIN SERVICE PANEL (INSIDE HOUSE) 5`�� I to qo,� PITCH-15° INV -INVERTER ESR r AZIM.-180° E UTILITY METER I I I I I I I �/ CB -COMBINER BOX (E) I I _ 1 1 (N)FUSED AC DISCONNECT ACD -AC DISCONNECT SHEET NAME i ROOF PLAN & I I I I LC -LOAD CENTER MODULES Roo-#a 41_011 TY PITCH-15° uM -UTILI METER AZIM.-270° SHEET SIZE 16'-711 341911 I MSP MAIN SERVICE PANEL ANSI B ROOF#5 ROOF#6 -VENT,ATTIC FAN(ROOF OBSTRUCTION) 1111 X 17" (7)SILFAB SOLAR: SIL-320 BL 320W (3)SILFAB SOLAR: SIL-320 BL 320W ROOF ATTACHMENT 1 ROOF PLAN & MODULES MONO MODULES WITH ENPHASE MONO MODULES WITH ENPHASE _---- SHEET NUMBER IQ7-60-2-US MICRO INVERTERS IQ7-60-2-US MICRO INVERTERS -RAFTER PV-2 PV-2 SCALE: 1/8"=V-0" -CONDUIT CIRCUIT LEGENDS BILL OF MATERIALS CIRCUIT#1 EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 36 SILFAB SOLAR:SIL-320 BL 320W <a, __ 7 w CIRCUIT#2 MICRO INVERTERS 36 ENPHASE IQ7-60-2-US MICRO INVERTERS J J SOLADECKS 6 SOLADECKS ui CIRCUIT#3 MODULE CLAMPS 44 MID MODULE CLAMPS Q 0 w END CLAMPS 56 END CLAMPS I STOPPER SLEEVE ¢F w ATTACHMENTS 114 EVERFLASH XP COMP `n ° o BOLT 114 LAG BOLT 0,o0 REVISIONS DESCRIPTION DATE REV SD INITIAL 08/13/2020 • ,tj��s y��OQG I i 9C 36"FIRE SETBACK I I I I I ---i 36"FIRE SETBACK CIRCUIT#1 I �G�OP��OQG� SD (12 MODULES) ■ ■ - #-- --- ---a �5• 5 r_ `PG DATE:08/13/2020 SD MSP PROJECT NAME&ADDRESS CB ACD I F-- I I I f T I I I I I I Is m 1 ±— O4 I I i i Z Li) - CIRCUIT#2 i W v8; I W - Cr) (12 MODULES) ■ ` F�e9 Jz L6 � so C� W He z0 I----------J 0) co o = _ W M5. SD--L-- } , O a I• ��G��PG�: i -R•- -i "6� N NO DRAWN BY r TA7E OF ESR -/ - .-- -I- SHEET NAME ��i�►�,ruuii*ia�`` CIRCUIT CIRCUIT#3 LAYOUT (12 MODULES) THIS PLAN HAS BEEN ELECTRONICALLY SIGNED AM SHEET SIZE SEALED BY SCOTT WYSSUNG,PE USING A DIGITP N SIGNATURE AND DATE. PRINTED COPIES OF TMI. ANSI B DOCUMENT ARE NOT CONSIDERED SIGNED AND 11�� X 17" SEALED AND THE SIGNATURE MUST BE VERIFIED = t1�1 SHEET NUMBER 1 ROOF PLAN WITH CIRCUIT LAYOUT ANY EL.ECTR0NIC COPIES PV-2A PV-2A SCALE: 1/8"=1'-0" 3 w � \ Z � v C) m N D m rn 4 r rn m 0 rn c m O m z cn '- C G v z " 3 z G7 D z 0 rn m m D v rn n 3 p T O m O p z 3 3 N � n G) m v m O mrn 0 T N m m p 3 (f In, 0 O -rI m S -O 1�T1 w N , - mm - rn m � Z m rn m m I O_ 0 S r Z .A (� x T 0 O m O m D 9_ z m / . W N O OD x W I O 30 '- m O rrrrr / 0 p v ( „ LORI SINGLETON m RESIDENCE -� r o f�� SOLAR Xfnm m m W W W m r 9' { > o £ n CZn 5301 17TH STSIGORA SOLAR LLC m rn m v ro 490 WESTFIELD R D STE A z , N --' ZEPHYRHILLS, FL 33542 CHARLOTTESVILLE,VA22901 DC SYSTEM SIZE:11.520 kW DC INTERCONNECTION NOTES: GROUNDING&GENERAL NOTES: AC SYSTEM SIZE:8.640 kW AC 1.INTERCONNECTION SIZING,LIMITATIONS AND COMPLIANCE 1.A SECOND FACILITY GROUNDING ELECTRODE IS NOT REQUIRED PER[NEC DETERMINED IN ACCORDANCE WITH[NEC 705.12],AND[NEC 690.64]. 690.47(C)(3)] 3.GROUND FAULT PROTECTION IN ACCORDANCE WITH[NEC 215.9], 2.PV INVERTER IS UNGROUNDED,TRANSFORMER-LESS TYPE. (36)SILFAB SOLAR:SIL-320 BL MONO MODULES [NEC 230.95]AND[NEC 690.51 3.DC GEC AND AC EGC TO REMAIN UNSPLICED,OR SPLICED TO EXISTING ¢N WITH(36)ENPHASE IQ7-60-2-US MICRO INVERTERSv w 4.ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. ELECTRODE (3)BRANCH CIRCUITS OF 12 MODULES CONNECTED IN PARALLEL o j 5.PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE 4.ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS [ � BUSBAR RELATIVE TO THE MAIN BREAKER. FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL V O g o ul INSPECTION. J DISCONNECT NOTES: 5.SOLADECK QUANTITIES,AND PLACEMENT SUBJECT TO CHANGE IN THE ! ^ /� Q W 1.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN FIELD-SOLADECKES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE V J V♦ o c THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE TYPE TRANSITIONS. O CONNECTED TO THE TERMINALS MARKED"LINE SIDE (TYPICALLY 6.AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER ' a THE UPPER TERMINALS) AC DISCONNECTING MEANS IS LOCATED WITHIN 10'OF SERVICE DISCONNECT v v 2.AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY 7.RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE PERSONNEL,BE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH INSTALLED MORE THAN 7/8"ABOVE THE ROOF USING CONDUIT SUPPORTS. 8.TEMPERATURE RATINGS OF ALL CONDUCTORS,TERMINATIONS,BREAKERS,OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR REVISIONS SILFAB SOLAR:SIL-320 BL 320W MONO MODULES AT LEAST 75 DEGREE C. DESCRIPTION DATE REv INITIAL 08/13/2020 LL BRANCH#1 I F 1 2 3 0 0 0 11 12 I ``\`�11\111111111///,1��J THIS PLAN HAS BEEN ELECTRONICALLY SIGNED AND NO s s o 0 0 SEALED BY SCOTT WYSSUNG,PE USING A DIGITAL TATS OF �` TO Ui( Z TILITY GRID SIGNATURE AND DATE. PRINTED COPIES OF THIS - -� DOCUMENT ARE NOT CONSIDERED SIGNED AND ipOa' QR�� ���� L2 SEALED AND THE SIGNATURE MUST BE VERIFIED �� OSIONA%-E � -x. M N BRANCH#2 I - ON ANY ELECTRONIC COPIES ///1111111111\\\\ BI-DIRECTIONAL UTILITY METER 1 2 3 0 0 0 11 12 I 1-PHASE,3-W, DATE:08/13/2020 + + ENPHASE X-IQ-AM1-240-3 PV FUSED AC DISCONNECT Li 120V/240V AC COMBINER BOX VISIBLE,LOCKABLE, L2 PROJECT NAME&ADDRESS L - - - - - I SOLAR LOADS ONLY LABELED,OPEN N SUPPLY SIDE UL 1741 COMPLIANT G ° - CONNECTION 0 0 0 s f 60A,240V,2-POLE LINE (E)MAIN BREAKER TO N 20A T I I HOUSE 240V,200A/2P z Nr - - - - - - L1 ° I " I I (E)MAIN SERVICE O Lu M PANEL,GE LLI V BRANCH#3 I SOLADECK, 20A I I Fuses I I I 200A RATED,240V J z = LLLL 1 2 3 0 0 0 11 12 I 600V,NEMA 3R, Li b, I I UI LIJ + _ +r' 'i r:EE ::l _ + I UL LISTED L2 I I LI I NOTER/LINE SIDE CONNECTION z 0 J L - - - - - - I 20A I ( I y AT MAIN PANEL U) I I LOAD N{ G N PER ART.705.12(D) W s s o 0 0 s r L1 N p ________r I I L1 I L— G O X BRANCH L _ —o— - - - G — J N [ J LLI TERMINATOR L - --C- - - -- GEC N (ET-TERM) ENPHASE IQ7-60-2-US VISIBLE,LOCKABLE, MICRO INVERTERS LABELED AC DISCONNECT 1 z LOCATED WITHIN 10' OF UTILITY METER EXISTING GROUNDING DRAWN BY ELECTRODE SYSTEM ESR QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SHEET NAME SIZE ELECTRICAL LINE ENPHASE ENGAGE CABLE(L1&L2 Q (6) #12AWG- NO NUETRAL) N/A NIA DIAGRAM (1) #6AWG- BARE COPPER IN FREE AIR SHEET SIZE (6) #10AWG- CU,THWN-2 EMT OR LFMC IN ATTIC 314" (1) #10AWG- CU,THWN-2 GND ANSI B (2) #6AWG- CU,THWN-2 (1) #SAWG- CU,THWN-2 N EMT,LFMC OR PVC 3/4" I 11" X 17" (1) #8AWG- CU,THWN-2 GND SHEET NUMBER 1 ELECTRICAL LINE DIAGRAM (2) #6AWG- CU,THWN-2 a (1) #6AWG- CU,THWN-2 N EMT,LFMC OR PVC 3/4" I PV-4 PV-4 j SCALE:NTS (1) #8AWG- CU,THWN-2 GND Oh 0< CAUTION _o POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED (/) a W SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: J N mi REVISIONS (N)S0LADECK(TYP.) DESCRIPTION DATE REV PV ARRAY INITIAL 08/13/2020 THIS P ri ' LAN HAS BEEN ELECTRONICALLY (N)COMBINER BOX SIGNED AND (E)MAIN SERVICE PANEL SEALED BY SCOTT WYSSLING,PE USING A DIGITAL DATE:08/13/2020 (INSIDE HOUSE) SIGNATURE AND DATE. PRINTED COPIES OF THIS PROJECT NAME&ADDRESS DOCUMENT ARE NOT CONSIDERED SIGNED AND (E)UTILITY METER SEALED AND THE SIGNATURE MUST BE VERIFIED (N)AC DISCONNECT ON ANY ELECTRONIC COPIES N �����11i{i{IHttt z E "/�S /j� 0 M 5301 17TH ST, ZEPHYRHILLS, FL 33542 • • —ts. J z —I— fn DIRECTORY z � r TATS OF a PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. /J/JfiSSlONA`uiiit ,��` - LU M 0 a (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: J N NEC 690.56(B)&(C), [NEC 705.10]) MAIN SERVICE PANEL LABELING DIAGRAM: (E)SUB PANEL DIRECTORY (ONLY IF POINT OF INTERCONNECTION DRAWN BY PV COMBINER/ IS MADE WITHIN ❑7 INVERTER AC DISCONNECT SUB PANEL) ® o o ESR JUNCTION BOX/ SOLADECK ® a o n 0 O SHEET NAME ® - ° PLACARD 3 LABELING NOTES: © © SHEET SIZE $1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT (ONLY IF PV (ONLY IF PV INTERCONNECTION INTERCONNECTION REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. ONSISTS OF LOAD CONSISTS OF LOAD ANSI B 2.LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE,OSHA STANDARD 19010.145,ANSI Z535. SIDE BREAKER) SIDE BREAKER) 3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. .11" X 17" 4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED[NEC 110.21] **ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY.NOT AN ACTUAL REPRESENATION SHEET NUMBER 5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8",WHITE ON RED BACKGROUND;REFLECTIVE,AND PERMANENTLY OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED.LABEL LOCATIONS PRESENTED MAY VERY DEPENDING AFFIXED[IFC 605.11.1.1] ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ELECTRICAL DIAGRAM PAGE.** PV-5 1 -10 11 -20 21-30 31 -40 41 -50 51 -60 61 -70 o V WN N t ^J O o V goW(/)(I/) ¢~W oNO I øoa�5 a REVISIONS DESCRIPTION DATE REV INITIAL 08113/2020 l 4 -LI __ __ DATE:08/13/2020 PROJECT NAME&ADDRESS ■ ■ N ■ z It 6 • O LI W M_______ Z m - C9 W ti • Z D � J 7 • ■ ■ VjyJ im' 5. O LL 0 ■ . ■ J W N DRAWN BY ESR SHEET NAME 9 MICRO INVERTER I CHART THIS PLAN HAS BEEN ELECTRONICALLY SIGNED AND :• NO. •• SHEET SIZE SEALED BY SCOTT WYSSUNG.PE USING A DIGITAL ANSI B SIGNATURE AND DATE. PRINTED COPIES OF THIS TATS OF a DOCUMENT ARE NOT CONSIDERED SIGNED AND Oa+aP 11" X17" 1 0 SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES ''4i�fisS10NAL E,� SHEET NUMBER 1111111,11111+A PV-6 a N 0 WN 30 Test Conditions STC NOCT 0 O W �� ; • • Module Power(Pmax) W 320 239.4 ("(1') � /� LL w st Maximum power Volta a(V max) V 34.36 - 32.18 V♦V♦ p(O s Maximum powercurrent(I max) A 9.32 7.44 y S . O n circuit volta a(Voc) V 42.04 39.5 88v If � Short circuit current Isc) %A 8.8 7..60 Module efficien % 18.84 17.60 Maximum system voltage(VDC) V 1000 Sr Series fuse rating A 20 Power Tolerance Wp 0 to+10 REVISIONS Measurement conditions:SIC 1OOO W/m2•AM 1.5•Temperature 25°C•NOCT 8OO W/m'•AM 1.5•Measurement uncertainty s 3% DESCRIPTION DATE REV •Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by t5%and power by O to+1OW . _. _ - --- - INITIAL 08/13/2020 DNV•GL "r AYr0Wn�iD roween - - - ._-__.�.___. Temperature Coefficient Isc +0.046%/°C Temperature Coefficient Voc -0.279%/°C Temperature Coefficient Pmax - --0.377%/°C INDUSTRY LEADING WARRANTY NOcr(±2°C) 435°C All our products include an industry o eratin tem erature _ -40/+85°C PAilItill leading 25-year product workmanship and 30-year performance warranty. Module weight _ _ 18.2 kg 40.1±0.4 lbs Dimensions(H x L x D) 1700 mm x 1000 mm x 38 mm I 66.9 in x 39.4 in x 1.5 in # * MAXIMUM ENERGY OUTPUT Maximum surface load(wind/snow)* 4000 Pa rear load/5400 Pa front load 83.5/112.8 lb/ftA2 Silfab BC Series utilizes next generation Hail impact resistance m 25 mm at 83 km/h o 1 in at 51.6 m h Back Contact technology to reduce Cells 126 high-efficiency half-cut mono-PERC 126 high-efficiency half-cut mono-PERC production/manufacturing steps and MVVT ttai ce,ls ansMW i tai cells improve quality while maximizing power. Glass 3.2 mm high transmittance,tempered,DSM 0.126 in high transmittance,tempered,DSM p anti-reflective coati anti-reflective coating Ideal for residential and commercial Cables and connectors(referto installation manual) 1000 mm o 5.7 mm,MC4 compatible 39.4 in, o 0.22 in,MC4 compatible projects where maximum power density Backsheet Multllayer,integrated insulation film and electrically conductive backsheet DATE:08/13/2020 is preferred. Frame Anodized Aluminum(Black) PROJECT NAME&ADDRESS B p ass diodes 3 diodes-30SQ045T(45VmaxDCblocking voltage,30A max forward rectified current) NORTH AMERICAN QUALITY unction Box UL 3730 Certified,IP67 rated Silfab is the leading automated solar Module product workmanship warranty 25 ars** module manufacturer in North America. o CV 30 ears Utilizing premium quality materials and Linear power performance guarantee t 97%end 1n Year ≥90%end 12t5 year 1 >82%end 25°j year z 80%end 30"'Year Z LO strict quality control management to ' = O M deliver the highest efficiency,premium ULC ORD C1703,UL 1703,CEC listed.Product durability proven up to 3 x IEC, W quality PV modules 100%made in Product climate chamber tests up to DH3000-TC600-HF30,UL Fire PY°duct climate chamber tests up to DH3000-TC600-HF30,UL RatinType 11 W IU North America. Factory 1509001:2015 0 J Z = U Modules Per Pallet:26 Pallets PerTruck:36 Z 0 n J :Modules Per Truck:936 sa.sr(laooeunl 1.s•(3amm) " J *Please refer to the Safety and Installation Manual for mounting specifications. - _ -t-1-I )r--- E r = **12 year extendable to 25 years subject to registration and conditions outlined under'Warrant?' 8 W O • • 0 atwww.silfabsolar.com. } *A Warning:Read the installation and User Manual before handling installing and operating modules. O a Third-party generated pan files from Fraunhofer-Institute for Solar Energy Systems ISE are 39.srt1050eW E J L1J available for download at:www.silfabsolar.com/downloads g N Is ■ 5� EIiE a DRAWN BY £P•& . . a ESR oil G't2eme> SHEET NAME Silfab Solar Inc. 240CourtneyparkDriveEast g EQUIPMENT 6.'• Mississauga ON L5T2Y3 Canada Go n°I"°H°° • ��17B�t°�� SPECIFICATION fa Tel+1 905-255-2501 I Fax+1 905-696-0267 g info@silfabsolar.com I w.silfabsolar.com SHEET SIZE a © Silfab Solar Inc. 6 800 Cornwall Ave ww Bellingham WA 98225 USA ANSI B Tel+1 360-569-4733 11"r X 171 r SHEET NUMBER PV-7 Q N 0!� W N ._I Data Sheet Enphase IQ 7 and iQ 7+ Microinverters 0g o Enphase Microinverters INPUT DATA(DC) 1Q7-60-2-US IQ7PLUS-72-2-US f ^ C"LL n Region AMERICAS Commonly used module pairings' 235W-350W+ 235 W-440 W+ V)V J O Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules (9 O0 Maximum Input DC voltage 48 V 60 V IN rn o tr Peak power tracking voltage 27 V-37 V 27 V-45 V v U Operating range 16V-48V 16V-60V Min/Max start voltage 22 V/48 V 22 V/60 V `r Max DC short circuit current(module Isc) 15 A 15 A Overvolta eclassDC art 11 11 REVISIONS EnphaEnphase The high-powered smart grid-ready s p se ,,, DC port backfeed current 0 A 0 A DESCRIPTION DATE REV Enphase( Micro and Enphase IQ 7+Micro PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; INITIAL 08/13/2020 I Q 7 and i Q 7+ dramatically simplify the installation process while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter 10 7+Mlorolnverter Microl nve rters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous ogtput power 240 VA 290 VA Nominal(L L)voltage/range' 240 V/ 208 V/ 240 V/ 208 V/ IQ 7+Microinverters integrate with the Enphase 211.264 V 183-229 V 211-264 V 183-229 V IQ Envoy",Enphase IQ Battery",and the Enphase Maximum continuous output current 1.D A(240 V) 1.15 A(208 V) 1.21 A(240V) 1.39A(208V) Enli hten'monitoring and analysis software. E to ne frequency euecy 47-6 47 g y Extended range 47-68 Hz 47-58 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed current 0 A 04 Power factor setting 1.0 1.0 enabling Enphase to provide an industry-leading Power factor(adjustable) 0.85 0.85 la in 0.85 leadin 0.85 lagging leading••• 99 99��• 99 9 warranty of up to 25 years. EFFICIENCY @240 V @208V @240 V _ @208 V DATE:08/13/2020 Peak efficiency 97-6% 97.6% 97S% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% PROJECT NAME&ADDRESS MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7-60-2-US&IQ7PLU5.72.2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) hV Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Z Lightweight and simple Weight 1.08 kg(2.38 Ibs) 0 W ce)idl1 Faster installation with improved,lighter two-wire cabling Cooling Natural convection-No fans F- M Built-in rapid shutdown compliant(NEC 2014&2017) Approved for wet locations Yes W U LL Pollution degree P03 n Z i Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure 0 Productive and Reliable Environmental category/UV exposure rating NEMA Type 6/outdoor Z 0 J_ Optimized for high powered 60-cell and 72-cell*modules FEATURES W W r 2 More than a million hours of testing Communication Power Line Communication(PLC) W M } • Class II double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. to Both options require installation of an Enphase 1O Envoy. • UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break O W disconnect required by NEC 690. N Compliance CA Rule 21(UL 1741-SA) Smart Grid Ready UL 62109-1.U11741/1EEE1547.FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 N0.107.1-01 Complies with advanced grid support,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and frequency ride-through requirements NEC-2017 section 690.12 and C22.1.2015 Rule 64.218 Rapid Shutdown of PV Systems,for AC DRAWN BY • Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements I ESR Configurable for varying grid profiles Meets CA Rule 21(UL 1741-SA) SHEET NAME • EQUIPMENT The 10 7+Micro is required to support 72-cell modules. l 1.No enforced Dc/Ac ratio.Seethe compatibility calculator at 2. htto�/fennh�;e.com.rp Og gypQptlLgr95�U!eSpm�LLh}ilty. p Nominal voltage range can be extended beyond nominal if required by the utility. SPEC I SPECIFICATION 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. SHEET SIZE EN PHASE. To learn more about Enphase offerings,visit enphase.com EN PHASE To learn more about Enphase offerings,visit enphase.com t� pEnergy g p Energy. ANSI B >h 2019 Err here All rr his reserveo.All trademarks or brands used are the properly cf Enlxrase Ener inc 2019326 11rrX 17" SHEET NUMBER PV-8 W N OData Sheet Enphase IQ Combiner 3 J Enphase Networking J MODEL NUMBER r. 0,W IQ Combiner 3 X IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy`printed circuit board for integrated revenue grade PV w production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). 0 V)r ACCESSORIES and REPLACEMENT PARTS(not included,order separately) O iY Enphase Mobile Connect'" = CELLMODEM-03(4G/12-year data plan) Plug and play Industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01(313/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1(4G based LTE-M/5-year data plan) where there Is adequate cellular service in the Installation area.) - ' The Enphase IQ Combiner 3'" with Enphase Consumption Monitoring*CT REVISIONS Enphase CT-200-SPLIT Split core current transformers enable whole home consumption metering(+/-2.5%). DESCRIPTION DATE REV IQ Envoy'consolidates interconnection Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. 10 Combiner 3 BRK-1OA-2.240 Circuit breaker.2pole,1OA,EatonBR210 INITIAL 08/13/2020equipment into a single enclosure and BRK-15A-2-240 Circuit breaker,2pole.15A,EatonBR215 (X-IQ-AM1-240-3) streamlines PV and storage installations by BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity 2 providing a consistent,pre-wired solution for XA-PLUG-120.3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) residential applications. It offers up to four XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS 2-pole input circuits and Eaton BR series Rating Continuous duty busbar assembly. System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.continuous current rating(Input from PV) 64 A DATE:08/13/2020 Max.total branch circuit breaker rating(input) BOA of distributed generation/90A with IQ Envoy breaker included PROJECT NAME&ADDRESS Smart Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy Includes IQ Envoy for communication MECHANICAL DATA and control Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm 19.5"x 14.75 x 6.63).Height is 21.06' 53.5 cm with mounting brackets). Flexible networking supports Wi-Fi, tv F° i —� Ethernet,or cellular Weight 7.5 kg(16.5 Ibs) Z k Ambient temperature range -40°C to+46°C(-40°to 115°F) Q W• OptionalACreceptacleavailablefarPLC Mbridge Cooling Natural convection,plus heat shield I— J• Provides production metering and optional Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction ._ Zconsumption monitoring Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors (960 A breaker branch Input: 4 to 1/0 AWG copper conductors v W ti J Main lug combined output: 10to2/0 AWG copper conductors Z i0 Simple • Neutral and ground: 14 to 1/0 copper conductors E U) T- _ Always follow local code requirements for conductor sizing. W CO • Reduced size from previous combiner Altitude To 2000 meters(6,560 feet) to >- Centered mounting brackets support single INTERNET CONNECTION OPTIONS o stud mounting Integrated Wi-Fi 802.11b/g/n -J N Supports back and side conduit entry Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) • Up to four 2-pole branch circuits for 240 VAC Cellular Optional,CELLMODEM-01(313)or CELLMODEM-03(4G) or CELLMODEM-M1(4G based LTE-M) f!. _ plug-in breakers(not included) (not included) • 80 A total PV or storage branch circuits COMPLIANCE -- DRAWN BY Compliance,Combiner UL 1741 CAN/CSA C22.2 No.107.1 I Reliable 47 CFR,Part 15,Class B,ICES 003 I ESR Production metering:ANSI C12.20 accuracy class 0.5(PV production) • Durable NRTL-certified NEMA type Compliance,10 Envoy UL 606111.1/CANCSA 22.2 No.61010.1 I SHEET NAME 3R enclosure * pmonitoring required g Systems. EQUIPMENT *Consumption is for Enphase Storage • Five-year warranty SPECIFICATION UL listed LISTED To learn more about Enphase offerings,visit enphase.com SHEET SIZE EN P H A S E- Sr 2018 Enphase Energy All rights reserved.All vademarks or brands in this document are registered by(heir respective owner e EN P H A S E. To learn more about Enphase offerings,visit enphase.com t/ 2018-09.13 '`'� ANSI B 11" X17" SHEET NUMBER PV-9 '4.) Q W N J�Q V goJ CrossRail System — N W> V)to QFw Stek\1 10 ;r 14 REVISIONS DESCRIPTI 08/1=02 ON DATE REV 11 9 INITIAL 0 Mechanical Properties �- , I -- •Material •6000 Series Aluminum Ultimate Tensile Strength 37.7 ksi(260 MPa) Yield Strength 34.8 ksi (240 MPa) Weight 0.47 lbs/ft(0.699 kg/m) �'^^~ finish Mill or Dark Anodized Section Properties DATE:08/13/2020 3 s I — Sx 0.1490 in (0.3785 cm 3) PROJECT NAME&ADDRESS 1 EverFlash XP Comp Kit, Mill or Dark 14000060, 4000061,4000057 0.1450 in'(0,3683 cm-i A(X-Section) 0.4050 in2(1.0287 cm2) Lag Bolt D145/16 x 4" 55 4000359 Z It 3 L-Foot XP Set, Mill or Dark 4000036,4000038 O I... W F- M 4 CrossRail 80 168" Rail, Mill 4000508 - 1391 14216.40 J Z fl1,54 166 0 LU F- J 5 CrossRail 80 End Cap, Black 4001221 ' Z CrossRail 48-XL 166',Mill or Dark 4000695, 4000705 _ _ ' W co I44 r 7 CrossRail 48-X/48-XL End Cap or Flat End Cap 4000433,4000431 1.73 �Hi O D= J W CrossRail 48-X 166" or 180", Mill of Dark 4000662,4000675,4000663 :_ 9 Cross Rail 48-X/48-XL 3" Sleeve 4000583 Dimensions in(mm] Inches iCr CrossRail 44-X 166", Mill or Dark 4000019,4000020 DRAWN BY Notes: ESR 11 CrossRail 44-X End Cap 4000067 Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-16 12 CR Mid Clamp Silver or Dark 4000601-H,4000602-H UL2703 Listed System for Fire and Bonding SHEET NAME EQUIPMENT 13 CR End Clamp Silver or Dark 4000429,4000430 SPECIFICATION 14 Yeti Clamp(Hidden End Clamp) 40000050-H SHEET SIZE a a.ev rest solarsysYems.com . .3aar�bt s;,lars,bL3ros.caiis ANSI B 11" X17" SHEET NUMBER PV-10 O di EverFlash XP Comp C�—' o �W> ' 4 - g REVISIONS DESCRIPTION DATE REV _ - - INITIAL 08/1312020 � T DATE:08/13/2020 PROJECT NAME&ADDRESS N z 1* Part Number Descriution O M rFl XP K; ion EPDM sealing LJ.I 4- E I XP m Kit. Dark I washer on lag W 4 z LL bolt Vr W FF_ uj ti J FEW Z 0 T- J ci Everest's very own comp shingle flashing and mount! W 0 W u7• Best in class •3 stages of waterproofing O W N All CrossRail hardware included and preassembled LIL 441 Section 27 Rain DRAWN BY TAS 100-95 Wind diiven rain test " I ESR SHEET NAME EQUIPMENT Dome provides fully Butyl gasket seals SPECIFICATION encapsulated raised L-Foot-Flashing con- SHEET SIZE seal nection ANSI B 11" X17" www.everest-solarsystems.com SHEET NUMBER EverFlash XP Comp Product Sheet US02 l 1019 Subject to change•Product illustrations are exemplary and may differ from the original. PV-1 1 Qrn O W N J f GENERAL GUIDELINES Q 3 J Always refer to roofing manufacturer SolaDeck's instructions prior to starting work. I1:) Refer to the American Wood Council's guidelines for Lag pull-out capacities(NOS 2005,Table 11.2A). O rn o Everest Solar recommends consulting a professional roofer prior to beginning work. FLASHED PY ROOF-M£71lr'IT COMBINER/ENCLOSt1RE C Installer is responsible for verifying the structural integrity of the roof prior to installation. . a U Basic Features ASSEMBLY:STEP BY STEP • Stamped Seamless Construction 18 Gauge Galvanized Steel ' " REVISIONS Locale the rafters and snap horizontal and vertical lines to mark the installation position for — ' each EverFlash flashing. • Powder Coated Surfaces - DESCRIPTION DATE REV • Flashes into the roof deck INITIAL 08/13/2020 I Materials required.Tape measure,string line + 3 Roof deck knockouts .5", .75", 1„ _ • 5 Centering dimples for entry/exit fittings or conduit • 2 Position Ground lug installed t+',✓ Drill a pilot hole(114"diameter)for the lag bolt.Remove any saw dust and fill the hole with the roofing manufacturer's recommended sealant • Mounting Hardware Included } J SolaDeck Model SD 0783 Materials required;Drill SolaDeck UL50 Type 3R Enclosures Insert the flashing so the to part is under the next row o`shingles and pushed far enough Available Models: g p pa 9 P 9 Model SD 0783-(3"fixed Din Rail) up slope t0 prevent water infiltration through vertical joint In shingles.The leading edge of Model SD 0786-(6"slotted Din Rail) flashing must butt against upper row of nails to prevent turning when tourqued. Materials required:EverFlash flashing DATE08J13/2020 PROJECT NAME&ADDRESS SolaDeck UL 1741 Combiner/Enclosures Line up pilot hole with EverFlash flashing hole.Insert the lag bolt through the EPDM bonded Models SD 0783-41 and SD 078ti-41 are labeled and ETL listed UL STD 1741 washer,the L-Foot,the gasketed hole in the flashing and into the rafter. according to the UL STD 1741 for photovoltaic combiner enclosures. Max Rated-60OVDC,120AMPS NN =f: — a} z tt) i Model SD 0783-41 3"Fixed Din Rail fastened using Norlock System 0 M • *"Typical System Configuration w U J Torque:The range is between 8.3-11.6 lb-ft depending on the type of wood and time of 4-Din Rail Mounted Fuse Holders 600VDC 30 AMP J z year.The visual indicator for proper torque is when the EPDM on the underside of the bonded +' 1-Power Distribution Block 600VDC 175AMP Ur W H in I washer begins to push out the sides as the washer compresses.If using an impact wrench to 1-Bus Bar with UL lug z ô p, J install the fasteners be careful not to over torque the Iastener.You may need to stop and use a Model SD 0786-41 6'Slotted Din Rail fastened using steel studs ratchet to finish the install. (n "Typical System Configuration W CO IY 4-Din Rail Mounted Fuse Holders 600VDC 30 AMP to 4-Din Rail Mounted Terminal Blocks O tl •'r. y.`:;'' �' Install Everest MoLntirg System(refer to Cross-ail 48/80 installation manual) Bus Bars with UL lug J LU 'Ii=...., N "'Fuse holders and terminal blocks -' s added In the field must be UL listed or recognized and meet 800 VDC 30 AMP 110C for fuse holders,600V 50 AMP DRAWN BY 90C for rail mounted terminal blocks I V l � and 600 V 175 AMP 90C for Power ESR Distribution Blocks,Use Copper Wire `{ Conductors. ✓ I 11 f�Etr � Cover is trimmed to allow Model SD 0783-41,wired with Model SD 0786-41,wired with SHEET NAME ,.rwA nm.."vy.,u+a.._ conduit ar fittings,base is Din Rail mounted ruse holders, Din Rail mounted fuse holders, EQUIPMENT Everest Solar Systems,LLC .. r..-. ..- - ,'•..• " «•. center dimpled for fitting bus bar and power distribution terminal blocks and bus bars. . ,. ,e s-a•,-.�N,.....,�,e as t.rh+u locations,The EverFlash is simple and fast to 3809 Ocean Ranch Blvd.,Suite 111 bus .'"-- ax�A.�. .,�Y,''-" block. SPECIFICATION install.Please contact us for further Oceanside,CA 92056 assistance: Service-Hotline+1.760.301.5300 RSTC Enterprises, Inc.2219 Heimstead Road.Eau Cl/are, WI 54703 SHEET SIZE info@everest-solarsystems.com SERVICE-HOTLINE+1 760.301.5300 w ea.everest-solarsystems.com I For product information call 1(866) 367-7782 ANSI B 11" X 17" SHEET NUMBER LPV-12