Loading...
HomeMy WebLinkAbout20-667 m _ p T City, Of ZephyrhillS _PERMITAUMBER� } - ,, � t•, 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-000667-2020 Phone: (813)780-0020 } Fax: (813)780-0021 Issue Date: 09/16/2020 Permit Type: Electric Service Replacement/Misc j Property Number.. =Street.Address fi 04 26 21 0060 00300 0050 36140 Shady Bluff Loop 0" r.Informatl6n .'.° Permit`information COntractO�InforlYlatlotl Name: FLORDALIZA COLLAZO Permit Type:Electric Service Replacement/M Contractor: US SO R Class of Work:Add/Alter Residential Address: 36140 Shady Bluff Loop Building Valuation:$0.00 ZEPHYRHILLS,FL 33541 Electrical Valuation:$5,000.00 Phone: (813)846-0281 Mechanical Valuation: Plumbing Valuation: Total Valuation:$5,000.00 Total Fees:$97.50 r Amount Paid:$97.50 Date Paid:9/16/2020 2:29:32PM Project INSTALLATION ROOF MOUNT SOLAR Application Fees` Electrical Permit Fee $65.00 Electrical Plan Review Fee $32.50 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever'is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording'your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER %813-780-0020 City of Zephyrhills Permit Application �/Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting L-'-813 )�808 0218 * Rag - - - Owner's Name Flordaliza Collazo Owner Phone Number (813) 846-0281 36140 Shady Bluff Loop,Zephyrhills,Florida 33541 Owner's Address Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 36140 Shady Bluff Loop, Zephyrhills, Florida 33541 LOT# SUBDIVISION Silverado-Phase IA PARCEL ID# 04-26-21-oo6o-o030O-OO5O (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTRF__1 ADD/ALT SIGN DEMOLISH R INSTALL F—] REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME 0 STEEL DESCRIPTION OF WORK ROOF MOUNTED�SOLAR PANEL INSTALL BUILDING SIZE SQ FOOTAGE HEIGHT .-AL-AL 1E'X'3LX =BUILDING 1$ VALUATION OF TOTAL CONSTRUCTION ®ELECTRICAL 1$ 5,000 1 AMP SERVICE 0 PROGRESS ENERGY W.R.E.C. =PLUMBING $ =MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY OW OTHER Solar: $29,837 FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES NO BUILDER i, COMPANY SIGNATURE REGISTERED Y/N —1 FEE CURREN ",LfLN J Address License# ELECTRICIAN COMPANY GENESIS ELECTRIC SERVICES LLC SIGNATURE REGISTERED Y/N FEE CURREN LYLN-L] 468 WATERFORD CIRCLE WEST TARPON SPRINGS, 34688 EC13907-122-"'Address License# PLUMBER COMPANY SIGNATURE REGISTERED FEE CURREN LILN__j Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/_ Address License# OTHER us SOLAR LAR SIGNATURE REGISTERED Y/N FEE CURREN LI±N J Address 2732 Broadway Blvd. Brandon FL 335101 License# CVC 57002 11-11 2.if.111111. 111 1-1 113-1-3 x a JIAI 11 11 4,91 111-1_14!J11-1 a a 11.I a a a a if 1 1,a a a t I I I-a x I a a 1.2 ff I I a a a a I RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions:' 4 %%% Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C'upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department r ; NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees mayj;apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the'owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"Vi° unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted'at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may,be required%TL Wectrical work,plumbing,signs,wells, pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TP OBTAIN FINANCING, CONSULT WITH YOUR LEN12ER OR AN ATTORN Y BEFORE RECORDING YOUR NOT! F COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) 144 CONTRACTOR �" Subs ri ed nd swo td`or ffirmed fo a me this 1 20by ( Leann)Wes Who is/are personally known to me or has/have produced DL as identification. Notary Public ommission No.GG 959064 JASON MONCHGESANG Name of Notary typed,printed or stamped JASON S. MONCHGESANG ,r° 9 Notary Public-State of Florida =• OE Commission# GG 959064 �!? ,;� My Commission Expires February 17, 2024 ar Leval EScpettS who Cate To whom it may concern, i 1,Seann Gates,CVC57002,hereby:authorize,the following to act as my agent(s)and.are authorized to Sign/pick up permits. Jason Wncl gesang Vanessa Delri,o License Holder's Signature: rk Date;. ea/��Xo State..of: County of: f-f7 + +Or`Ottq�, Before me, personally,appeared, S"Nn f': IGA7-6 S ,who produced as,identificatiomor is,personally known to me,and who did affirm and subscribed before me this _ day of '41, Gt 20 „I Signature otary Public Aix Seal. ,,sri,a;;8;,, C: KYLE:WALKER ;i� Notary i'}ibiie•State of Florida = Name of Notary Typed Printed or Stamped =* � COnamis3i'on#.HH 29.4 My Commission.Expires y ''"+ �,• May 14,2Q24 My.Commission.Expires: t j df ®2�f CONTRACT FOR SALE AND INSTALLATION OF A 8.99 SYSTEM (hereinafter the"System")by and between US Solar Squared,LLC(hereafter"Seller"whose address is below provided)and Flordaliza Collazo Edwin Collazo •(hereinafterjointly or severally"Buyer")whose address is 36140 Shady Bluff Loop,7rnhyrhilis Florida 33541 according to the terms and conditions hereafter stated. Buyer understands and agrees that this contract is binding only when accepted by Seller by having its duly authorized company officer or member execute this contract.Buyer further understands and agrees that the full contract price for purchase and installation of the System shall be the following price S34.837.00 unless amended by subsequent agreement of the parties.Buyer further acknowledges and agrees that Buyer is not to give the sales agent presenting me this contract any money or check as the sales agent is an independent contractor and is not authorized to collect money on behalf of Seller. TERMS AND CONDITIONS MECHANIC'SLIENNOTICE: ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001 - 713.37, FLORIDA STATUTES),THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND ARE NOT PAID IN FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY IF YOUR CONTRACTOR OR SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUBSUBCONTRACTORS, OR MATERIAL SUPPLIERS. THE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YOURSELF,YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FORM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY. BUYER'S RIGHT TO CANCEL This is a home solicitation sale,and if you do not want the goods or services,you may cancel this contract by providing written notice to the Seller in person,by telegram,or by mail.This notice must indicate that you do not want the goods or services and must be delivered or postmarked before midnight of the third business day after you sign this contract. If you cancel this contract,the seller may not keep all or part of any cash down payment. Date Buyer signed this contract is: 8/14/2020 _.If Buyer decides to cancel this contract,Buyer will send the cancellation notice to Seller at its address provided below within three business days after this date. By signing below,Buyer agrees to the terms and conditions stated above and on the reverse side of this page. Buyer(s): If tilarrled .¢❑oust must sign as well). OocuSigded'by: DocuSigned by: By (fop By�lA (40,fi6 AFMB80133264B1... �A"F_DB8013326481... ACCEPTANCE:By signing below,Seller hereby accepts Buyer's offer according to the terms and conditions stated above and on the reverse side. DocuSigned by: US Solar Squared,LLC B 2732 Broadway Center Blvd. Seann es,Crat Pres1 ent Brandon,Florida 33510 2DA49473688B49A..: State License#CVC57002 Date Accepted 8/14/2020 CHAPTER 558 NOTICE OF CLAIM CHAPTER 558, FLORIDA STATUTES, CONTAINS IMPORTANT REQUIREMENTS YOU MUST FOLLOW BEFORE YOU MAY BRING ANY LEGAL ACTION FOR AN ALLEGED CONSTRUCTION DEFECT. SIXTY DAYS BEFORE YOU BRING ANY LEGAL ACTION, YOU MUST DELIVER TO TIME OTHER PARTY TO THIS CONTRACT A WRITTEN NOTICE, REFERRING TO CHAPTER 558, OF ANY CONSTRUCTION CONDITIONS YOU ALLEGE ARE DEFECTIVE AND PROVIDE SUCH PERSON THE OPPORTUNITY TO INSPECT THE ALLEGED CONSTRUCTION DEFECTS AND TO CONSIDER MAIQNG AN OFFER TO REPAIR OR PAY FOR THE ALLEGED CONSTRUCTION DEFECTS. YOU ARE NOT OBLIGATED TO ACCEPT ANY OFFER WHICH MAY BE MADE.THERE ARE STRICT DEADLINES AND PROCEDURES UNDER THIS FLORIDA LAW WHICH MUST BE MET AND FOLLOWED TO PROTECT YOUR INTERESTS. Installation11.10 1.INCORPORATION:The parties agree that the terms and provisions set forth on the front page are incorporated into this contract by reference. 2.JOB SPECIFICATIONS:The specifications for the System arc set forth in the work order attached hereto and incorporated herein by reference. The contract price set forth on the front page shall include i)the purchase of the System described in the work order; ii)the installation of the System by Seller or its subcontractor,and iii)costs of supplies and materials used in the installation of the System. Buyer agrees to be fully responsible for all sales taxes,if any,levied in connection with the purchase and installation of the System.Unless otherwise set forth in this contract, the installation shall occur at the address of Buyer stated in the preamble.It is the obligation of the Buyer to provide Seller or its subcontractor utility services so that Seller may properly install the System. 3.SERVICE AGREEMENT:Buyer agrees that this is not a contract governed under Chapter 672,Florida Statutes, as this is a contract primarily for the installation of the System.Seller is not responsible for securing for Buyer any Federal Tax Credit,State or Power Company rebate,if any. 4.FINANCING:If Buyer does not have the funds readily available to pay the contract price following the installation of the System,Buyer agrees to apply to a financing company to pay the contract price on forms provided by the financing company.Such application shall be undertaken by Buyer independent of Seller whom Buyer agrees is neither Buyer's agent nor the agent of the financing company in connection with any loan application.If Buyer applied for financing in connection with this contract,Buyer understands that Seller will not accept Buyer's offer unless the financing is approved by a duly licensed financing institution in good standing in the State of Florida.If Seller accepts Buyer's offer and thereafter learns that the financing has not been issued,or if issued is then withdrawn by the financing company,Seller may terminate this contract without any liability to Buyer. 5.WARRANTY:Seller agrees,on condition that the full contract price has been paid on completion of the installation of the System,to warrant the operation of the System for one year following its installation.If,during this one year period,the System or any its components should fail to operate in accordance with the manufacturer's specifications,Seller agrees to replace or repair the System at its sole cost and expense, including parts, supplies and labor.US Solar provides a 10 year Workmanship Warranty and a 5 year Roof Penetration Warranty. 6.LIMITATIONS OF WARRANTY:The warranty of repair and replacement given by Seller in paragraph 5 above shall be null and void if Buyer or anyone else shall damage or improperly maintain or operate the System, or should injury or damage be caused the System by fire,rain,freeze, storm(including hurricane)or any other force majeure or act of God.Furthermore,Buyer acknowledges and agrees that the proper maintenance and operation of the System is dependent upon the conditions of proper design,construction and maintenance of Buyer's property and building(and pool if applicable)where the System is to be installed and operated,and that the plumbing and electrical services serving Buyer's property are adequate to maintain and operate the System as intended once installed.If the System fails to operate within the manufacturer's specifications because of the failure of any of these conditions,then the warranty of Seller is null and void.Furthermore,it is specifically agreed that SELLER DOES NOT PROVIDE AN IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AS TO THE SYSTEM BEING INSTALLED. 7. LIMITATION OF LIABILITY:The exclusive obligation and liability of Seller, and that of its officers,subcontractors,agents and employees, to Buyer for any direct, indirect or consequential damages arising from or related to i) the failure of the System to operate according to the manufacturer's specifications,or ii) damage to the property or building of Buyer due to a defect in the System or to the negligent or improper installation of the System,or iii) for any personal injury(including death) caused Buyer by a defect in the System or its improper or negligent installation is limited to the contract price;and,except to that extent,the Buyer hereby releases,discharges and waives any other claim or demand for damages,injuries or losses of any kind or nature,or any other suit or action that Buyer may or does have against Seller,or any of its officers, employees or agents,based upon a defect in the manufacture, installation or operation of the System, including any claim, demand, suit or action Buyer might or could make or bring for the negligent installation of the System by Seller and its officers, subcontractors,agents and employees. Furthermore,neither Seller nor any of its officers,subcontractors,employees or agents,shall be liable for any damage caused to the building or property of the Buyer during the installation of the System unless Buyer serves written notice on Seller of the alleged damages within five(5)days following installation. 8.ARBITRATION:Any dispute arising under or related to this contract,including any tort action arising out of or related to the installation of the System,shall,if not resolved by the parties,be referred to binding arbitration.Only a court of competent jurisdiction shall have the right to determine if the subject matter of the proposed arbitration comes within the terms of this arbitration provision if the parties disagree as to the arbitrability of the matter. Arbitration shall be conducted in the Hillsborough County, Florida in accordance with Commercial Arbitration Rules of the American Arbitration Association then pertaining,and judgment on any award rendered in such arbitration may be entered in any state or federal court.The parties agree to allow the American Arbitration Association to choose the arbitrator,and its decision as to the selected arbitrator shall be binding unless either party can show the chosen arbitrator to be incompetent or biased for or against any party.Notices in connection with such arbitration must be served by personal delivery or certified mail, return receipt requested,on Seller at its address stated on the front page hereto. Costs of arbitration,including the filing costs and related arbitrator fees,shall be awarded as determined by the arbitrator, but only a court having jurisdiction over the parties may make a determination whether attorneys fees are recoverable,and if so, in what amount Notwithstanding the foregoing,the parties hereto,and those in privity with the parties hereto,agree that any action or suit to foreclose a mechanics lien brought pursuant to Chapter 713,Florida Statutes,shall be exempt from the application of this arbitration agreement. 9.MERGER:This contract, if accepted by Seller,represents the final expression of the representations,terms and covenants of the relationship established between Seller and Buyer and the installation of the System. Buyer agrees that Buyer is not relying upon any other representation or statement made heretofore by any sales agent,independent contractor or representative of Seller to Buyer as an inducement to enter into this contract, and Buyer releases Seller from any other inducement or representation that is not included herein,even if such representation was material to Buyer's decision to enter into this contract.Buyer agrees that only an officer or member of Seller has the authority to bind Seller to this contract,or waive or modify any of its terns.Furthermore,Buyer understands and agrees that no sales agent,independent contractor or employee of Seller has the right to promise Buyer that any rebate of any sort will be made or given with respect to the purchase or installation of the System. 10.GOVERNING LAW,VENUE:This contract is to be construed under and governed by the laws of the State of Florida.Any action,suit or other proceeding between the parties hereto,whether or not such action,suit or proceeding arises under this contract,shall be brought in Hillsborough County,Florida;and the parties agree to waive venue in any other county.However, if the suit or action includes a mechanic's lien foreclosure, venue shall be placed in the county where the System was installed. 11. NON-ASSIGNABILITY:Buyer may not assign this contract,nor any of Buyer's rights hereunder,to another. 12. PAYMENT:Buyer agrees to pay the full contract price on completion of the installation of the System,time being of the essence. 13. DEPOSIT:If the work order given in connection with this contract provides for Buyer to give Seller a deposit as a condition of Seller accepting Buyer's offer,Buyer shall have the right to withdraw its offer if the amount of the deposit is not agreeable to Buyer. Payment of the deposit to Seller's employee shall be conclusively deemed Buyer's agreement to enter into this contract and pay the deposit. Despite accepting such deposit, Seller shall not be obligated to apply for any permit within thirty days of accepting the deposit or commence work within 90 days of the permit(s) being issued,and the parties hereto waive application of Florida Statute§489.126(2)to the extent it applies to this contract,if at all. 14. ACCEPTANCE:If Seller does not provide notice to Buyer that Seller has accepted Buyer's offer within forty days following the date Buyer signs this contract,Buyer's offer to enter into this contract shall expire.However, should Seller proceed to install the System following expiration of the acceptance period with Buyer's knowledge and approval,then the parties hereto shall be bound by the terms of this contract. Installation 1.10 INSTR#2020143106 OR BK 10168 PG 250 Page 1 of 1 08/31/2020 03:11 PM Rcpt:2198918 Rec:10.00 IDS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller Permit No. Parcel IONo 04-26-2i-oo6o-oO30o-0o5O NOTICE OF COMMENCEMENT State of Florida cdunydf Pasco THE UNDERSIGNED hereby gives notice that Improvement WJl be made th certain real property,and in accordance vAth Chapter 713.Florida Statutes, ore fosovMg Information is provided In this Notice of Commencement t. Description of Property.Parcel idenb6cabon No.04-26-21-oo60-00300-0050 SILVERADO-PHASE 1A PB 61 PG o71 BLOCK 3 LOT 5 OR 9331 StreelAddrew 3614o Shady Bluff Loop,Zephyrhills,Florida 33.r,41 2. General Descnpuon of Improvement Roof Mounted Solar Panel Install 3. Owner Information or Lessee Intonation it the Lessee==ad for the Improvement Flordaliza Collazo Name g( nS=RlofTnon ZephYrhills FL Address, 300% city State Interest In Property: Name of Fee Simple Tlileholder. (If diilerem from Owner Wad above) Address Cry Stale d, Contractor. US SOLAR �73 RROADWAYCENTERBLVD. BRANDON FL adarees city state Contractors Telephone No.: 800-351-3430 5. Surety: Name Address Cdy State Amount of Bond:S Telephone No.: 6. Lender. Name Address Cdy State Lendefa Telephww No.: 7. Perrone vANn the Slate of Florida designated by the owner upon wham notices a other documents may be served 03 Provided by Section 71ll.13(1)(Q)(7),Florida Statutes: Name Address Cdy State Telephone Number of Designated Person: 8 In addtion to himself,the owner designates oT_ to lecelve a copy o1 the Uenors Noble as prWded In Section 713.13(1)(b).Florida Statutes. Telephone Mintier of Person or Entity Designated by Owner. A F.Iraton date of Notice of Commencement(me expiration data may rot be before the dompl tom of construction and final payment to the contractor but vda be one year from the date of recording unless a different cafe 19 spec6ea): WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 713,13.FLORIDA STATUTES.AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENDING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Underpenaly of pe)<iry.I dedam that 1 have mad the foregoing notice of commencement and mat the facts stated therein are We to the best of my knowleepe are bellel.STATE OF FLORIDA COUNTY OF PASCO o0-ter 0 Signature 010VemerOlL095ee, owners aLes!¢e's AtMonZ orroarrolfedorfPaMerlManager HOMEOWNER Slgnatorys Trilsoffice The foregoing Instrument was acmowledged before Mel his I.4%of AUG �20by Flordaliza Collazo es FTQMR0VTNFR (t" au y,ag.0"Sg ee tomey In lee a SELF (name orP ehadafx Ins l —aexe Penwaily Known❑211 Produced Identification IX Notary Signal— Type a Identification Produced DTI Name(Pnn) JASON MONCHGESAlfG ;y,V' r, JASON S.MONCHGESANG Notary Public-State Of Florida s Commlasion/GO 9B9084 -,'�rrrR���,•,' My Commieeion Expirats February 17,Z024 wpdatWbcsftdce=nmenameNycD53008 F Vi 8.99kW SOLAR ARRAY PLANS * Iyo�7479 .< PROJECT DESCRIPTION: GENERAL NOTES: FOR 29 MODULES - MISSION SOLAR: MSE310TS60 {1� 29 INVERTERS - ENPHASE: IQ7-6O-2-US 1. THIS IS TO CERTIFY THAT TO THE BEST OF •• T OF ;•�q; MY KNOWLEDGE AND BELIEF, THESE PLANS FLO R DALI LA C O LLAZ O CONFORM WITH FLORIDA BUILDING CODE 2017 GOVERNING CODES: WITH ALL SUPPLEMENTS AND ADDITIONS. 361 40 SHADY BLUFF LOOP 2017 FLORIDA PLUMBING CODE, 6TH EDITION 2. ALL PRODUCTS TO BE INSTALLED PER 2017 FLORIDA BUILDING CODE, 6TH EDITION MANUFACTURER'S WRITTEN SPECIFICATIONS. 2017 FLORIDA MECHANICAL CODE, 6TH EDITION I, ANDREW D. HALL PE# 87479 AN ENGINEER ZEPHYR H L LS, FLORIDA 33 5 41 NNEC FPA 1 2015 201 LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN 0° THE MOST RECENT VERSION OF THE FBC, FBC C)__ 107. U Wind Design Data ,C3 0 Wind Speed 140 mph P. EAVE Risk Category 11 m Z Exposure C z oho o w Gust Factor ±0.18 a - o "A"Dimension 5.1 ft o Roof Pressure for Components and Cladding Zone 1 16.47 psf -25.65 psf J Zone 2 16.47 psf -44.55 psf r, Zone 3 16.47 psf -66.15 psf Z o O rn DISCONNECT -� o MIN. 4' CLEARANCE • i . ¢o PER NEC 110.26(A) .t.. , 3' MIN.lYP Lu Zr,, '' MISSION SOLAR: I �' H z u r7 MSE310TS60 (TYP) Z TYP. RIDGE _ ✓_ ALL WORK SMALL COMPLY WITH PREVAILING CODES FLORA SIi ..€ INC CODE, NATIONAL ELECTRIC CODE, AND THE CITY OF ZEPHYRHILLS ORDINANCES r-6'MIN.TYP REVIEW DATE SEP 0 3 2020 OBSTRUC110N CITY OF ZEPHYRHILLS , PLAN EXAMINER o a DRAWING INDEX: � m S-1 COVER C S-2 ARRAY LAYOUT & DETAILS S-3 ELECTRICAL N TYP. RAVES-4 NOTES = Z "' U MODULE ROOF LAYOUT S-5 SPECIFICATIONS CN/) MS S-6 SPECIFICATIONS Q S-7 SPECIFICATIONS S-8 SPECIFICATIONS W.NO. S- 1 Cl � m u, °0 Cl C p� 0)C7 N Cl Cl C7 0o W Cl cl Cl \ _\ Cl N cn x OC - = G o CA U) z m m Cl C Cl C-� - >< -1 iTJ C Z D Cl Cl z G oo cmcn ClCl ClCl z W 0 —H Cl (n U) p (1) � � N 1. 01 X m Cl - C) Cl C)C'Cl o � I � � L O Cl Cl ClC C7 Z D C7 l7 Cl Cl Cl D -I C- C- m O CCl Cl Cl 7 Cl Cl Cl Cl a - ___ � W cn N rncn C m ClCl PER MANUFACTURER'S o Cl SPECIFICATIONS n I Cl Cl Cl Cl Cl C-) C7 C) C7 ' Cl Cl -o 11 CLIENT: US SOLAR CVC57002 DRAWN BY: BCC CHECKED BY:A.D. HALL r `< UNIQUE ENGINEERING SOLUTIONS LLC C./ PROJECT NAME: FL0RDALIZA C0LLAZ0 _ 3253 COMMERCIAL WAY DATE: 8/31/20 0 �: NADDRESS: 36140 SHADY BLUFF LOOP SPRING HILL, FLORIDA 34606 SCALE: AS NOTED PHONE (352) 345-8443 COA# 30913 - ARRAY LAYOUT & DETAILS JOB NO. : 220-504 °®�f,�l • .• ,,�®'' r SEAL.,, BACK-FEED BREAKER CALCULATION: $ '• T TE of :�✓.° (MAIN BREAKER X 0.2) + (BUSBAR - MAIN BREAKER) = MAX BREAKER SIZE -, �� ,o?:••';�` (150 X 0.2) + (225 - 150) = 105 AMPS ii, Cdr p�7 0� J d d W LU #6 THWN-2 (3 CONDUCTOR) NOTE: 3/4" EMT, FMC, FOR EXTERIOR ALL INVERTERS ARE EQUIPPED APPLICATION USE PVC OR W/ INTERNAL RAPID SHUTDOWN LFMC/LFNMC CONDUIT #6 THWN-2 (3 CONDUCTOR) SYSTEM PER NEC 690.12 o o 3/4" EMT, FMC, FOR EXTERIOR m z N LOCKABLE FUSED APPLCATION USE PVC OR PV AC DISCONNECT LFMC/LFNMC CONDUIT ENPHASE Q CABLE MISSION SOLAR: MSE310TS60 3 a 6DA 240V 2-POLE #10 THWN-2 (3 CONDUCTOR) ENPHASE Q CABLE W/ ENPHASE 107-60-2-US o o N o 40A RK-1 FUSE 3/4" EMT, FMC, FOR EXTERIOR Q-12-10-240 Q-12-10-240 INVERTER APPLCATION USE PVC (TYP) (TYP) u OR LFMC CONDUIT N L2 L1 ZO N, METER AC AC ¢ M c DC DC o L1 L1 in o L2 L2 NO. 1 NO. 15 o z0 ZW - .- N SPACE �] 20 MR-RL14 (PP) l a SPACE 20 Lu J Ln 20 = MJ HNC') G NO. 1 NO. 14 NOTE: z M 11501 G ALL STRINGS TO HAVE ,Z NAC AC TERMINATORS & SEALING CAPS ? #6 THWN 2 DC DC INSTALLED PER MANUFACTURER'S 40 SOLADECK COMBINER BOX SPECIFICATIONS z NEUTRAL GROUND 600V/ NON-FUSED OR SOLTECTION RESIDENTIAL ENPHASE Q CABLE MISSION SOLAR: MSE31OTS60 TRANSITION BOX I Q-12-10-240 W/ ENPHASE IQ7-60-2-US ENPHASE IQ COMBINER PLUS (TYP) INVERTER W/ (2) 20 AMP BREAKER EGG & GEC BOND AT RACKING SYSTEM NEUTRAL GROUND (SEE NOTE #2) AC PANEL 225 AMP/240V C) o a m U c O = N w O M z U w O in W U a Q W DWG.NO. S-3 * 74 79 OF : NOTES: ',��ii '•• C?�b �+ 1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT MODULE SPECIFICATION INVERTER SPECIFICATION SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND MODULE MAKE MISSION SOLAR INVERTER MAKE ENPHASE STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. 2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43. MODULE MODEL MSE310TS60 INVERTER MODEL IQ7-60-2-US US 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D). _ FSEC CERTIFICATION ft MAX AC POWER OUTPUT 250 VA 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS PMAX (STC) 310 w MAX. INPUT VOLTAGE 48 V RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE r� voc (STC) 40.30 V NOM. DC VOLTAGE © 240V 240 V ITEMS IDENTIFIED IN NOTE 1. NOM. AC VOLTAGE 16 48 V 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING VMPP (STC) 33.10 V v MAX. CONTINUOUS OUTPUT CURRENT 1 00 A MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING-ELECTRIC SHOCK HAZARD - DO = ISC (STC) 9.94 A NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN IMPP (STC) 9.45 A MAX. DC CURRENT 15.0 A POSITION OR EQUIVALENT. NOCT 46 C MAX. DC POWER (STC) 350 W 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON TO ISC 0.040 %/C CEC EFFICIENCY 97 % THE PREMISES AT SERVICE ENTRANCE. _ TC VOC -0.280 7/C 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. m N o N 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION. TC PMPP -0.380 %/C 9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED OPERATING TEMP. -40-+85 C z z TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE 3 HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO ¢ m Q U 3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS. NEC 310.15 (B)(2) LABELS AND MARKINGS GENERAL NOTES: N AN EM ER CE I V CY Co I V TACT 10. ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE NEC. )IPMENT SUCH AS INVERTERS AND SOLAR MODULES HAVE 12.PV ARRAY INTERCONNECTION TO BE MADE WITH BACK-FEED BREAKER. z :-APPLIED LABELS FOUND HEREIN SHALL BE APPLIED TO SUCH US SOLAR 13.GFI BUILT IN TO ALL INVERTERS. OJ CO IIPMENT EL FOR INFORMATIONAL S ANDMARKINGSSHALL BE APPLIED TO COMPONENTS IN 1 -813-44-O284 o ¢ >- CD 3 .ORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. o o REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV Z. CDo ;ISTANT OUTDOOR-RATED LAMINATED VINYL IN ACCORDANCE WITH ' 'I Z535.4-2011. W -CD _ Lo ZN- ' LABELS AND MARKINGS LEGEND V( N Z N z IDT2 w U' ATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN o !VICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT Or C. z ERVICE DISCONNECT MARKING ' CAUTI ON SOLAR PHOTOVOLTAIC SYSTEM Ai ABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE ® -WARNING- �ONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT THIS SERVICE IS SUPPLIED BY MULTIPLE -WARNING- ELECTRIC SHOCK HAZARD. THE DC tRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH SOURCES. SEE DISCONNECTS BELOW. AUTHORIZED PERSONNEL ONLY CONDUCTORS ARE OF R NDE DAIC SYSTEM UNGROUNDED AND TE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A RATED AC CURRENT: 36.3A MAY BE ENERGIZED RN / AUTHORIZED PERSONNEL ONLY JSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." NOMINAL AC VOLTAGE: 240V LOCATION: DISCONNECTS, INVERTERS, MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER w ac NO LOCATION: MAIN PV PANEL JUNCTION BOXES, OTHER ENCLOSES ;ISTANT, AND SUITABLE FOR THE ENVIRONMENT. HOLDING DC CONDUCTORS CD DISCONNECTING MEANS MARKING r O 'ERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT PHOTOVOLTAIC DISCONNECT AKER CONTROLLING THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM CTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL LETTERS AT l -WARNING- A4 o w ST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: ELECTRIC SHOCK HAZARD PHOTOVOLTAIC SYSTEM EQUIPPED Z OTOVOLTAIC DISCONNECT." THE LABEL SHALL BE CONSTRUCTED OF WfIN RAPID SYSTEM SHUTDOWN DO NOT TOUCH TERMINALS. TERMINALS ON = N BOTH AND ABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL. EENERRGIZEE� THE LOAD SIDES BEuJ OPENPOS ON. U a cm z LOCATION: AC DISCONNECT(S) M.N0. S-4 t ' • xvBEW o * 87479 ie� ,,•• �\,ems Enphase IQ 7 and IQ 7+ Microinverters ',f tj7 , Electrical Parameters at Standard Test conditions(STCJ INPUT©ATA(1)C) 107-60-2-US 1Q7PLUS-72-2-US _._._________ .._._.-....._...., Module Type MSE305TSE0 MSE310TS60 ILA- '" uODA Commonly used module pairings 235W-350W+ 235W 440W+Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules o PowerOutput Pmax Wp 305 310 UaA Maximum input fdG voltage a5 V h0 V Module Efficiency M 18 2 18.5 I Peak power tracking voltage 27V-37V 27V-45V Tolerance 1+3% 1+3% 4o P' a Operating range 16V 43V 16V-60V Short-circuitcur nt ISO A 9.90 9-94 I Mm/Max5artvoltage 22V/48V 22V160V t J � Max Dr,shr circuit current(module twA iS A 1S A c=> Open Circuit Voltage Voc V 40.10 40.30 . One vtitan class DC port it 11 Rated.Current Imp .. 9.39 9-45 -irA tpk' ma "A 4A. seo CC port vnick€eed current 0 A 0 A 0 Rated Voltage Vmp V 32.80 33.10 vatxag®i PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; o c� a Cu rent&Voltage Power VoltageAC side protection requires max 20A per branch circuit M o C-4 OUTPUT DATA(AC) iQ 7 Microinverter IQ 7+Microinverter z `~ Current-voltagecharacteristicswith dependence on irradiance Peat,utputroarer 250 VA 295 VA m — `� o Maximum continuous output power 240 VA 290 VA 3 W Normal Operating Cell Temperature(NOC ° T) 46.7C(t2°C) BASIC DESIGN(UNITS. Inch(mm)) t Norniiial(r-L)voltagelrangea 240V1/ 208 V; 240V1 208V! i ¢o c Temperature Coefficient of Pmax -0.38%/°C L v94o 211-264 V 183-229V 211-264V 183-229V tootl Front View Maximum continuous output current 1.OA 115A 1.21A 1.39A Tsm ertltueeCoetNetentofVoc 028%J°C Ncrosnal frequency 60 Hz 60 Hz _.J Temperature Coefficient of Isc 0.04%/°C Extended frequency range 47-68 Hz 47-68 Hz AC short cii cult fault current over 3 cycles 5.8 Arms 5.8 Arms (I) Maximum units per 20 A(L-L)bran:h circuits 16(240 VAC) 13(240 VAC) 0 0 13(208 VAC) 11(208 VAC) r 0'✓rrrvoliagecla.sC AC port Ili 111 r CD Q Maximum System Voltage 1,(ilC'JL3C AC port backfeed current 0 A GA Operating Temperature Range -40°C to+85°C 65.95 Power factor netting 1.0 1.0 O (1 5) 1/) ¢ Maximum Series FussRati 20A Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading-..0.7lagging EFFICIENCY @240 V @208 V @240 V @208 V Z w O Fire Rating TYPE 1 Peak CEC affaelency 9?6 it 9?.6 Yra7.5% 973% H L` Max.design toads for 2 rail system CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% W C) Frmtt&Back Load 113 psi,downward,64 ,upward107W U = MECHANICAL DATA Microinverter Z Max.design toads for 3 tail system _,_,. __, _ __ �. _. NDu 178 psi,downward,64 psi,upward /n stem temperature range -40°C to+65"C " z Relative humidity range 4%to 100%(condensing) Z Corn for type MC4(or Ampli H4 UTX with additimal Q-DCC-5 adapter) W Back View Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) W stn-esq Side View D o Solar Celts P-type mono-crystalline silicon(156.75rnm) �j ln4i i 108 kg(2.38lbs) C &lo C Nl No f Z Cell Orientation 60 cells(6x10),5-bulbar Oba.rs: } ooling atura convec tion- ans4r�. 1675mm x 1001mm x 33mm Approved forwe,locations Yes Module Dimensions ases (65.951n.x 39.401n,x 1.301n.) l J Pollution degree PD3 •Øe - Enclosure Class It double insulated,corrosion resistant poiymeracenctosura Wei 3zt ght 18.Ok9(39.71b) o Environmental category/UV exposure rating NEMA Type 6/outdoor 3.Zmm(O.lZ6in.)terrtperd tow iron, FEATURES FrorltGlass anti-refitd ve c04U199 ---- Communication Power tine Communication(Pt.C) Frame Anodized aluminum alloy Monitoring Enlighten Manager and MyEnlighten monitoring options. ta Both options require installation of an Enphase IQ Envoy. t rrc rsulattt Ethylene 1ltnyi acetate(EVA) 3 Nr I)seonwecting means The AC and DC connecters have'been evaluated and approved by UL for use as the lead break J-Box Protection class IP65 with 3 bypass-diodes disconnect required by NEC 690. sE Compliance CA Rule 21(UL 1741-SA) Cables PV wire,im(39.371rt.),4mm)j 12 AWG j UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B. ICES-0003 Class B, I CAN/CSA-022.2 NO.107.1-01 Connector MC4 connector •0r,₹;16' s This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and a NEC-2017 section 690.12 and C22.1.2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC t I and DC conductors,when installed according manufacturer's instructions.ClafrteaT _i 1.Na eniorcad OC/AC ratio.See the compatibility calcu;ator at h_iSA.s.;�etiphasE.a4.tD1&it:fastsuR.tL4ttJ225tdule.�4mpatibiiity �p Yrfelt Pine}-y 31 0 W 2.Nominal voltage range can be extended beyond nominal if required by the utility. ac,A(x#ati inc,,� 3.Limits may vary.Refer to local requ'rements to define the number of m;croinverters per branch in your area. o C) W J 53 30 900 27s.okw EN PHASE To learn more about Enphase offerings,visit enphase.com MISSION SOLAR ,{;18 En^l.c=.^e Energy.All lifts reso vc.ci.At trademarks or brands used urn the Prop ty or l.n5lttA0 c'.^e:gy.'nc ENE FtGY 211 CCO2-IS = lion Solar Enemy reserves the ri9h[to make changes without notice. Mission Solar Energy 18303 5.New Braunfels Ave.,San Antonio,Texas 78235 inro8mrssionsolar.wm lw..wsv,m..issirxnsa!acatta O i..i — h ~ �i1 L.i W Q p U d ¢ (J) OWO.NO. S-5 ai199I�,,.:er ��o`.�. •C E Lt f��7, •,, • 097479 :tk T r .:v • TAT OF hase Q — ii ��a Cable Accessories Enphase IQ Combiner 3 ii MODEL.NUMBER 3REGATOR SPECIFICATIONS 1Q Combir r8 IQ Combiner 3 with Enphase IQ Envoy'printed circuit board for integrated revenue grade PV legator . ... ........... Q-BA 3-1P-60(single-phase),Combines tip to three ntiCrr�inverter branches into one luAme runs. X-lO-A -3 production metering(ANSI C12 20+/-0..5%)and optional consumption manitoring(+1 2.5%). Protect with maximum 60 A,2-pole OCPD. ACCESSORIES and REPLACEMENT PARTS(not included,order separately) imercial Aggregator Q-BA-3-3P-35(three-phase).Combines up to three,single-phase microinverter branches into a three- Enphaaa Mobua Connect" m phase home run.Protect with maximum 40 A,3-pole OCPD. CELLMOD3M-03(4G/12-year date clan) Plug and play industrial grade cellular modwrrs with data plan for systems up to 00 CELL MODEM-Cl(30/5-year data plan) microinverters (Available in the US.Carted-a,Mexico.Puerto RIcn.and the US Virgin Islands, -- tweet 190 mm(W)x 227 mm(8)x80 met(H)17.5 in(W)x 9 in€(H x3.2 in(H)l CELLMODEM-M1(4G based LTE-M/5-year data plan) where?bare is adequatecetfulai set vlve in the installation area,) run conductor size range #12 to#4 AWG Consumption Monitoring*CT Split core current transformers enable whole hntne consumption metering(+/-2.-51) CT-200 SPLIT re rut n5 NEMA3(up to 45•from horizonrel} +Corsurnotion monitoring is recuired for Enohaee Storage System ereture range -40'C to+55'C(-40'F to+122'F) Wireless USS adapter Installed et the lQ Envoy For communicattons with phase Encharge storage and Enphase COMMS-I(IT 01 Enpo ver"smart switch.Includes LISP cable for connection to 14 Envoy of Enphase 1O.Corrrbmsr" o us Iranre UL1141(assembled product)and UL6/03(bulkhead connectors) and allows redundant wireless commtrrticetson with Eiacharge and Enpower. C O 01 Circuit Breakers Supports Eaton BR210,BR215,5R220,OR230,BR24O.98250,and BR260 circuit breakers. on z N 1UCTOR SPECIFICATIONS BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 cation Lli 3003(raw cable),UL 9703(cable assemblies),DG cable BRK-I SA-2-240 Circuit breaker,2 pole,15A,Eaton 9R215 m test rating FT4 BRK- OA-2P-240 Circuit breaker,2 pole,20A,Eaton BR270 Dance RoHS,OIL RES 1,CE,UV resistant,combined UL for the United States EPLC 07 Power Site carrier(c.ummurriratian hr€dye pa€i).quantity cite pair o V o XA-PLIJG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(requ€red for EPLC-01) rctor type THH N,rTH W N-2 dry/wet XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PGB)for Cow Wrier 3 reacting means The AC and DC bulhead connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690, ELECTRICAL SPECIFICATIONS 3LE TYPES)ORDERING OPTIONS Rating Continuous duty V) r2 Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box System voltage 120/240 VAC,60 Hz O CD tM40 277 VAC u m(4.2 ft Portrait 240 Eaton 8R series bulbar rating 125 A 7-240 277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 Max.continuous current rating(output to grid) 65A D >— co CD f!-2.00 277 VAC 2 3 m(7.5 ft) Landscape(72-cell) 2U;s Max.fuse/circuit rating(output) 90A 0 3 to ASE a CABLE ACCESSORIES Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DC)breakers only(not included) (I) ¢ o Model Number Description Max.contrnutsus current rating(input from PV) 64 A Cable Q-12-RAW-200 300 meters of 12AWG cable with no ecnnectors Max total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included H 00 vireable connector(mate) Q-CONN-10M Make connections from any Q Aggregator open connector Production Metering CT 200 A solid rare pre-installed and wired to IQ Envoy W CDD rn W = variable connector(female) O.CONN•10F Make connections from any Q Cable open connector MECHANICAL DATA Z ^ Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling t3imensiorrs(WxHxD) 49.5 x 37-5 x 16.8 cm(19 5'x 14.75°x 6 63").Haight is 21.06'(53.5 crn with mounting brackets). N Z inert tool Q-DISC•10 Disconnecttool for Q Gable connectors;DC connectors,and AC module mount Weight 7.5 kg(16.5 los) Z N W -egator sealing caps(male) Q-BA-CAP-10 Sealing cap for unused aggregator connections Ambient temperature range -40°r;to+46°C(-4EJ°to 115°F) j ZO d Sea€irag raga(tamale} Q-$EAL-1Q One needed to cover each unused connector on the oabl:ng Cooling Nature€convection,plus heat shield o� later Q TERM-10 Terminator cap for unused cable ends Ericicsure env€ronrnentai rating Outdoor,NRTL-certified,NEMA1ype 3R,pulycarbonate construction Z Demerit DC Adaptor(MC4) O-GCC-2 DC adaptor to MC4(max voltage 100 VDC) Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors D • 60 A breaker branch input: 4101/0 AWG copper conductors :ement DC Adaptor(UTX) Q-DCC-5 DC adaptor to UTX(max voltage 100 VAC) Main lug combined output: 10102/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. TERMINATOR SEALING CAPS Altitude To 2000 meters(6,560 feet) Tends,soldr cap for ks offunused cable Sealing ablecaps o for ecunused aggregator INTERNET CONNECTION OPTIONS ends,sold in packs of ten and cable connections w,.-_�,. _._-. _w w. ,w...,.. _.._�._..,...-,__„...._„„_ „,,..m.,_.�_._. ,..,_�.............„__._�,,, (Q-TERM-1 O (Q-BA-CAP-10 and Q-SEAL-1 D integrated Wt i i 802.1 tbtg/n Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) DISCONNECT TOOL CABLE CLIP Cellular Optional,CEI.E-M00EM-01(300 or CEt I MODEM--09(4f)or CELI MODEM-M1(40 based t TE-M} Loot includedl Plan to use at least one per Used to fasten cabling to the racking COMPLIANCE installation,sold in packs often or to secure looped cabling,sold in —.— -- — _ — __-____ ..... (Q-DISC-1 D) packs often(Q-CLIP-100) C,re li r,cc,Combiner UL 1/41,CAN/CSA C22 2 No.10/ 47 CPR,Part 15,Class B,ICES 003 Production metering ANSI C12 20 accuracy elate 0 5(PV production) Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 o o To learn more about Enphase offerings,visit en hase_4'�2s O O 1 more about Enphase offerings,visit enphase.com c b.,e d emu x or r e s s°r ;rS L;r."",,ha�e'rnsc,y.;29 ngi,ts reserver'.�_nphase;;i:a Enn'll so logo.. 'om .. ,an other vad: „ _-,:, ......_ the C) m P 3Y - `' _ EN PHASE. t, ,.`.'r:rr a :oergi'. lc. EN PHASE, Ease Ene.r Au ng`taresr:rved.All trader^arks or brr:,`s i,sec'rre; ere.crtr cf Enona^e€.new,}•.Inc F� n J N O w O C,,-, Z U W U W CL O rl U d ¢ (n OWG.NO, S-6 Q'; o No gf79 S�j �FI]�� ���ej o`vo Mount Installation Instructions MLM- Q illation Tools Required: tape measure, roofing bar, chalk line,stud finder, caulking gun, sealant compatible with roofing �, M pUI'1t ' , C�MLM-ST Trials,drill with 7/32"or 1/8"bit,drill or impact gun with 1/2"socket. Elevated Water Seal Technology® THIS EDGE TOWARDS ROOF RIDGE FLASHING. DESCRIPTION QTY.; C) FLASHING,ROUNDED CORNERS,9"X 12"X.040",.438"HOLE,5052, 1 MILL 2 L-FOOT,2"X 3.30"FOR.438"O.D.FASTENER,2-1/16"SLOT,6061- 1 Lo T6/6005A-T61,MILL - 'J'iZ8 3 WASHER,SEALING, 5/16"ID X 3/4"OD.EPDM BONDED SS I m N [ 4 LAG SCREW,HEX HEAD,5/I6"x4",18-8 SS 1 STRUCTURAL SCREW.QMPV,T-30 HEX WASHER HEAD,5/16"X4-112". 1 °D z 18-BSS 3 m 12.00 x5 e,choose,and mark centers of rafters to be Carefully liftcomposition roofshinglewith roofing Insert flashing between 1st and 2nd course.Slide Lted.Select the courses of shingles where bar, just above placement of mount. Remove up so top edge of flashing is at least-Y4"higher ...... Ltswill be placed. nails as required and backfill holes with aproved than the butt-edge of the 3rd course and lower i ;4.201' 'STRUCTURAL I r7 sealant.See"Proper Flashing Placement"on next flashingedge is above the butt-edge of 1st course. 3.00 3 SCREW Z page. Markcenterfordrilling. i AVAILABLE ON 0 QMLM-ST- - VERSIONS ONLY Eo C5 2 JO M v 1 H � tLOO — 13� i q0,i 1 AVAILABLE IN MILL, H N z N { U AND BLACK FINISHES Z rh Ln t L C nick Mount PV` a4C _._.__._.... ......................_....._.................._._..............._._.........................._..................._.. u., 0 L..TITLE..... chingwith tag bolt use a 7hz"bit(Lag).Usea Clean off any sawdust,and fill hole with sealant Place L-foot onto elevated flute and rotate L-foot to 13.54;' 4.04 (� (ST)for attaching with the structural screw. compatible with roofing materials, desired orientation. l 2,50,: 2.75 QMLM&QMLM-ST:L-MOUNT, Fi 2-1/16"SLOT itot hole into roof and rafter,taking care to ................. .................._.... i.------------------ 1 auare to the roof.Do not use mount as a drillQMLM-ST - 512E:DRAWN BY: RAD REV'QMLM �UNLBS OTHERWLSESPECIFIED: [ Drill a 2"deep hole into rafter amENs sffXWemkc"E •TOIFRANCn: A p. .. p I_ .... __....._._ .. .......... .__. ....... .......................... ....... .... ... FRAUONAL.18 A DATE. 7/16/2018 9 € 1 DH➢R DPAwM�•R{'n RO?ce',O�rxx-.,xwN,w..m uNrT .:cn.wlvr.l oR AtAwIro�[wnNaul u[ p NOTSCALEDRAMNG TWOPLAC 000c AL ..19 ....................... i xPa cw u wttdx...dxnwx R4�...COPYRLGaTO2016 o.REx MOUMPY [TRREE PUCE DECIMAL zW4 !SCALE.1.1 :WEIGHT'1.0723 SHEEP I OF 1 I. 5 4 3 2 I 4 O d e lag bolt or structural screw with sealing You are now ready for the rack of your choice. r. Using a'h-inch socket on an impact gun, Follow all the directions of the rack manufacturer ,.> w o L4_ Trepared lag bolt through L-foot until L-foot as well as the module manufacturer. NOTE: Make quick Mou n o U E3 1 longer easily rotate.DO NOT over-torque, sure top of L-Foot makes solid contact with racking. RESPECT THE R 00 F m Structural screw can be driven with T-30 hex o __ lit. Lr S .3-44 Jul-2018 Rev 4 617.2.3-44 Jul-2018 Rev 4 o o to LJ M F- rn z U Li U CD 3 LIJ DWG.NO. S-7 No17479 Quick mount PV • N UITM RESPECT THE ROOF Ingenuity in Engineering Rail Spans for Quick Mount PV QRail Light System Mean Roof Height: 0<h≤ 15 ft Panel Orientation: Portrait Table 3 Roof Angle: 7<0 ≤27 degrees Exposure Category: C Roof Ground Wind Speed(mph) o Wind Snow o m < Z N Zone Load 100 110 115 120 130 140 150 160 170 175 180 190 0 81 81 K 81 81 76 71 66 62 60 59 55 m o 10 76 75 74 73 71 69 67 .66 62 60 59 55 ¢ m 20 61 61 61 61 60 59 58 56 55 55 54 53 N o 30 52 52 52 52 52 5.2 51 50 50 49 49 48 Zone 40 45 45 45 45 45 45 45 45 45 45 45 44 1 50 41 41 41 41 41 41 41 41 41 41 41 41 60 38 38 38 38 38 38 38 38 38 38 38 38 Z o, 70 35 35 35 35 35 35 35 35 35 35 35 35 O o 80 33 33 33 33 33 33 33 33 33 33 33 33 90 31 31 31 31 31 31 31 31 31 31 31 31 0 7₹t 70 67 _64 .-599 55 51 48 45 43 42 40 o 10 76 70 67 64 ! 59 55 51 48 45 43 42 40 Z o 20 61 61 61 61 59 55 51 48 45 43 42 40 H �- 30 52 52 52 52 52 52 51 48 45 43 42 40 w o L) Zone 40 45 45 45 45 45 45 45 45 45 43 42 40 Z M = M 2 50 41 41 41 41 41 41 41 41 41 41 41 40 M 60 38 38 38 38 38 38 38 38 38 38 38 38 Z a M 70 35 35 35 35 35 35 35 35 35 35 35 35 w z 80 33 33 33 33 33 33 33 33 33 33 33 33 o 90 31 31 31 31 31 31 31 31 31 31 31 31 0 62 56 54 52 48 44 41 38 36 35 34 32 Z 10 62 56 54 52 48 44 41 38 36 35 34 32 20 61 56 54 52 48 44 41 38 36 35 34 32 30 52 52 52 52 48 44 41 38 36 35 34 32 Zone 40 45 45 45 45 45 44 41 38 36 35 34 32 3 50 41 41 41 41 41 41 41 38 36 35 34 32 60 38 38 38 38 38 38 38 38 36 35 34 32 70 35 35 35 35 35 35 35 35 35 35 34 32 80 33 33 33 33 33 33 33 33 33 33 33 32 90 31 31 31 31 31 31 31 31 31 31 31 31 Notes: 1. Tables are based on critical rail span for load combinations as specified in chapter 2 of the ASCE 7-10 and allowable design loads per the 2015 Aluminum Design Manual. C) o 2. Panels are assumed to be in portrait orientation with a maximum length of 67.5" o 959 Larchmont Court,Aurora,IL 60504 3/4/2019 L } 630-219-1997(P) ' www.structuralenginuityinc.com C3 '- o w o cn ZZ U U LO 5 w3 U o w U d (I) DWG.N0. S-8