Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-676
, D a own City Of Zephyrhills PERMIT NUf7MBER t , 1 5335 Eighth Street Zephyrhills, FL 33542 BNR-000676-2020 ., Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 11/17/2020 Permit Type: Building New (Residential) I Property'"�Nu_mber= �' Streef Address 04 26 210120 00000 0510 1 6510 Bradford Woods Drive ;� Owner Information A., . Permit Inf_�,orm_ation Contractor Infor,�mation Name: PULTE HOME COMPANY LLC Permit Type:Building New(Residential) Contractor: PULTE HOME COMPANY Class of Work:SFR Construct LLC Address: 2662 Falkenburg S Rd Building Valuation:$119,749.00 RIVERVIEW,FL 33578 Electrical Valuation:$5,493.00 Phone: (813)964-5182 Mechanical Valuation:$5,145.00 Plumbing Valuation:$5,147.00 Total Valuation:$135,534.00 Total Fees:$14,055.68 Amount Paid:$14,055.68 Date Paid:11/17/2020 8:23:04AM I ter.ject Des�cEription Iiii : CONSTRUCT SINGLE FAMILY 2,399 SQ FT Application FeesY° Bills Public Safety Impact Fee-Police $254.00 Plumbing Permit Fee $65.74 Driveway Fee $45.00 Mechanical Permit Fee $65.72 SIF 1 percent Fee $83.28 Mechanical Plan Review Fee $32.86 School Impact Fee $8,328.00 Plumbing Plan Review Fee $32.87 Building Plan Review Fee $314.37 Building Permit Fee $628.74 3/4 Water Meter Fee(Calc) $473.78 Sewer Connection Residential Fee $2,090.00 Water Connection Residential Fee $1,010.00 Electrical Plan Review Fee $33.73 Electrical Permit Fee $67.46 Irrigation 3/4 Meter(Calc) $473.78 Address Fee $30.00 Public Safety Impact Fee-Admin $26.35 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management; state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. --gpK - y)Q9L4_)L-9 n C N GNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INSTR#2020141514 OR 6K 10166 PG 771 Page 1 of 1 08128/2020 09:49 AM Rcpt.219BO66 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller Pemnl No. Pacai lD No NOTICE OF COMMENCEMENT staleor Florida Coumyof Pasco THE UNDERSIGNFD hereby gives notice that imptovcmenlvM be made to certain real plopetly,and In eccordencevM Chapter 713,Rodda Statutes, Ihefolowing bdomma0un Is provided in Me Notice of Commencement f" 1. pesalpllon ofPropedy:Parod N0. � v Desmtptinn� 2. New Construction - Single Family 3. Owner Information or Lessee Information if the Lessee contracted forlhe improvement: Pnl tp 14nmp Company. T.T.0 Name 2662 S Falkenburg Rd R;yp j6'W FL Address City state inlerestin Property: Fee Simple Name of Fee Stnple Titleholder_ _ - pldlferonitromOmrerlisfedeboue) , Address CRY Siaffi 4. Conbador. Pnitp TTomp Corrmzany, T.T,C 2662 SNTalkeltburg-Rd Riverview FL Addroso City stale Contreclm%Telephone No.: 813-964-5]1 5 s 9. surety. N/A Name Address City State Ammmt of Bond.Ser Telephone No.: 6. lender. N/A Name Address City Stale Lenders Telephone Na: T. Persons within the State of Florida designated by the owner upon whom nollose or ouaef documents may be aervad as provided by Secllon 713.13(l)(a)(7),Florida Slatulee. N/A None Address City State Telephone Number ofOrsignated Person: S. In adffifion ro tmirtmseu,the wrrmer desigretes N/A of_ to receive a copy of the Uenors Notice as povded In Section 713.13(1)(b),Florida Statutes. Telephone Number of Person erEday Designated by OMmer. a. EW nrwn dale of Notice of Commencement pfre eVimllon date may rot be before the emnplelion of cureb ction and final payment to the cdrdrsdor;but will be one year from[be date of reowdmg unless a different date Is sp=To*. WARNING TO OWNER: ANY PAYMENTS MADE aY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS TINDER CHAPTER 713.PART I.S£CnON713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IFYOU MEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penally of perjury.I dedaro that I terve read the foregohgf MUM of commencement and that time facts stated th sl a to the best of my knnwiedge and bew. STATE OF FLIIRRIDA COUNTY OF PASCO Si9mrahae or Lessee.aOarherso Lessees Autholimd OlTirerlDt clot G� SI orts'nuafmce, r�The foregoing Instrument was acknowledged before me thl day of�l02_O by Mat±--bpoc A-4 as Attornev in Fact otauumdir .e_-officer,trustee,emameyinfad)for PUlte TTom C=anr T•T,�___ (name of Mom mmRwas Pmsonaly Known®RR Produced Identification❑ NotarySigrnature._. ._ Type of(donbTleaucn Produced Name(Print) Dopf,A11G1&2023 g�drou�1d 61YeNldshc° V{J-/l7u-vv4v OILY UI Lt fpl Iyl 11111J rCl 1(II1.t-%P.r(IUdUU1 I i ax-u 10-1 oU-Uvr.i Building Department )ate Received Phone Contact:for Pennittin 1-i-TT fl�l�-I i /� )wner's Name pI L l kt .I" D(11 C Co )G{.(1 L; (�L OwnerPhone Number ��— I 'E5 1 1 r's Address 2u 2 S, Fa-l4ti burs J l i�e�t�I P j t� L ! Owner Phone Number )wne -ee Simple Titleholder Name / Owner Phone Number �^ --ee Simple Titleholder Address. !A JOB ADDRESS -JI � Vlit UVODdS r/ LOT#776 SUBDIVISION O��S 0 1 a�"O PARCEL ID#Ftoy—z(2—V-0120-ZDOX-0 0 (OBTAINED FROM PROPERTY TAX NOTICE) NORK PROPOSED e NEW COLSTR 8 RDDIALT EPAIR SIGN = DEMOLISH INS3ROPOSED USE Q SFR 0 COMM' = OTHER TYPE OF CONSTRUCTION �C 11 BLOCK Ej FRAME j'STEEL /Q )ESCRIPTION'OF WORK nes / 3UILDING SIZE SQ FOOTAGE HEIGHT =BUILDING $ I VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $�.� /yr�r ,y� AMP SERVICE 0�--�P/R`OOGRESS ENEERGY Q W.R.E.C. =PLUMBING $ =MECHANICAL $. 5�r/`—r� VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS /;j,f� D� J FLOOD ZONE AREA =YES NO BUILDER COMPANY lilk#O !t! SIGNATURE , REGISTERED Y/ N FEE CURREN n Y/N Address f/O��S� nC� i lVe'U/ell�l j 3 License# ELECTRICIAN COMPANY 5 r Gda SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address / /a q� � License# PLUMBER COMPANY SIGNATURE ,I REGISTERED Y/ N FEE CURREN Address 313� 3 �/GJ(l� I�FG 378� License# LJa�a��1 MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N _J FEE CURR Y/N l�/3 l7 nt6�'I Address �hJl, GtS�1,GL 341 cP(v? License#OTHER COMPANY �"� r"" a` SIGNATURE. REGISTERED Y! N J FEE CURREN Y/N Address IIg31/3/7//n Dr T&D License# 1111111l11111Il1lllllllilllillll11111l11111101llillllllllllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY.SURVEY required for all NEW construction. . . . : . . . . . . . . . . . . . : . . . . . ... . . . Directions: Fill out application completely_ Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over.$7500) *" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A!C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW v J — wV1 Ty 1.111w 1 I I na rar+Nna+auv� Building Department NOni ICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor,is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licbnsing Section at 727-847-8009. Furthermore, if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07.and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that.Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If.fhe project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify that 1,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks', Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with,the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF'.COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH MUR LEND bL FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Sub cribed and swot to(or a i ed for a this Su 7 r'bed and sworn_to r ffi e-d))befor me this 2a oG 2v20 by ILb ?L�� 2D2vby %fi/� LG�Z _ lerrritbC���w Who /ar ersonally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. as identification. /' G Notary Public ( / / Notary Public Co- sion No. (�/ S 7 Com r iss' No. �Y ��J L 71 _ 1 Ntkme of Notary typed,Printed or stamped Namb of Notary typed,printed or stamped PANICIA BURCHEIT PAiI1ICIA BURCHE IT MY COMMISSION#GG365171 edY�u�n My COMMISSION#GG365171 EXPIRES:AUG 13,2023 EXPIRES:AUG 13,2023 Bonded through 1 at State Insurance �' Bonded through 1 st State Insurance PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 51, OAKS OF PASCO AS RECORDED .IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT . = 5,750 SQ. FT. LIVING AREA = 1,850 SQ. FT. GARAGE = 438 SQ. FT. ENTRY = 21 SQ. FT. LANAI = 90 SQ. FT. Curve Table PATIO = 0' SQ. FT. DRIVEWAY = 328 SQ. FT. Curve# Length Radius I Delta Chard Bearing Chord A/C PAD = 9 SQ. FT. C1 6.53' 1 55.00' 6.48'13' N07-41-50"W 6.53' WALKWAY = 29 SQ. FT: IMPERVIOUS = 48% = 2765 SQ. FT. O Line Table' SOD = 2.985 SQ. FT. O z OFF LOT CALCULATIONS Line # Direction Length 1" = 30' RIGHT OF WAY = 396 SQ. FT. GRAPHIC SCALE L.1 N0417'44-W 43.48' -DRIVE APRON = 57 SQ. FT. PUBLIC S/W = 250 SQ. FT. 0 15 30 SOD = 89 SQ. FT. TOTALS AREA = 6,146 SQ. FT. DRIVEWAY = 385 SQ. FT. SIDEWALK = 279 SQ. FT. SOD = 3,074 SQ. FT. O I 01 I N \ 80,Z0 9BS0 \ �h (NON—RADIAL) ' 115.39'�9. N85'4216"E -34.5 O o A C n 60.0' 20.5' 60.00' DI J O :2 r I•:.:� a PR o O Gr PROPOSED - (• COVERED HIGHGAIE — C01 $ c r m 1=z .'1, .':_'1 EN Y FINISHED FLOOR O - Q D pz j ?.,. 5.3' ELEVATION=91.05' o COVERED 1^lµ m 0 zA l o i 20.5' > LANAI ;i (p �O 0 n� I m I 5.0' N 9.0' O 1^ '< 5.3', m O m> yo I O 2 p >ScI� 0 O> z C I is 51.0' - -..Cp -34.5' - > m I iz A'40 W 20.5' N .. } h �'o '16"W 115.00' ' cnS8542 � W IN 1 r0 om I ---I m I tp PREPARED FOR: I o0 0 pI-te� �uy1rr��1.-) BUILDING SETBACKS FRONT: 20' REAR: .' 10' SIDE: 5' SIDE STREET: 15' LEGEND: NOTES: — BUILDING SETBACK LINE PI POINT OF INTERSECTION NT OF CURVATURE I 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED — — CENTERLINE PT PC POPOINT OF TANGENCY ' ON THE APPROVED'ENGINEERING PLANS PREPARED — _ _ — RIGHT OF WAY LINE RP RADIUS POINT BY CORNELISON ENGINEERING & DESIGN INC. PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCP PERMANENT CONTROL POINT DATUM. TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES (P). PER PLAT CONCRETE CALCULATED PB ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PB PLAT BOOK THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PAGES OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SO. FT. SQUARE FEET DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM - SANITARY SE THIS IS NOT A SURVEY DE SS DRAINAGE EASEEMENT EASEMENT THIS IS A PLOT PLAN ONLY UE UTIUTY EASEMENT FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO289F, DATED SURVEYOR NOTES: 19/26/2014, AND FOUND THE SUBJECT PROPERTY APPEARS TO UE IN 1. THE SURVEYOR HAS NOT ABSTRACTED,THE ZONE'AE°, DENOTES AREAS DETERMINED TO BE SPECIAL FLOOD HAZARD LAND SHOWN HEREON FOR EASEMENTS,'RIGHT AREAS SUBJECT TO INUNDATION BY THE 1%ANNUAL CHANCE FLOOD OF WAY, RESTRICTIONS OF RECORD WHICH EVENT, BASE FLOOD ELEVATIONS DETERMINED TO BE 88.5'. THE MAY AFFECT THE TITLE OR USE OF THE LAND. SURVEYOR MAKES NO GUARANTEES AS TO'THE ABOVE INFORMATION. - 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF A5M 3. NOT VALID WITHOUT-THE AUTHENTIC BRADFORD WOODS DRIVE BEING N0417'44°W, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A M E R I CA N SURVEYOR AND MAPPER. (FIELD DATE;) S U F�V E Y I N G �°�°�'�°' ' 1" = 30 FEET wtcuur BOO (I DigitallyUS.igned by i James Boleman SCALE: Q� s;�;:N••, v DN:r-US,st=Florida,l=Orlando, JB LTG MAPPING INC.. :J�� �:•4`� —AMERICAN SURVEYING&MAPPING,. APPROVED BY: �6'" —L INC,—lames W Boleman, CERTIFICATION OF AUTHORIZATION NUMBER LB0393 may' .'.�� email=jboleman@asmmrporate.mm FOR 3191 MAGUIRE BOULEVARD, SUITE 200 ;•..,,"m p+� Date3020.10.071530.51-04'00' THE NO. 191105 LOT 51 ORLANDO, FLORIDA 32803 ��r °°°t Adobe Acrobat—Ion:11.0.23 FIRM REV. STRUCTURE 08/06/20 JIG (407) 426-7979 DRAWN BY.- RMB WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM 6485 DATE PLOT PLAN OB 04 2020 JG # 2662 Falkenburg Rd eTampa, FL 33578 ® Ph(813) 964-5115 Fax (813) 626-1407 October 22, 2020 To Whom It May Concern: Please accept the revised plans for-the permit referenced below. We are changing the elevation from Cl to CO1 (removes stone). Removing covered lanai extension, 4' garage extension, and changing the owner's bath from layout 2 to layout 1. If you have any questions,-please do not hesitate to contact me at 813-964-5182. Thank you. Oaks of Pasco Lot 51 6510 Bradford Woods BNR-000676-2020 Drive • Thanks, C�f� Patty Burchett Pulte Homes y �� lb V U13-78U-02U City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received a a a a € al a /`l Phone Contact for Permitting it 01r � a[ IL Owner's Name ' r t,° GrJ7�/ / Owner Phone Number Owner's Address ?��� 1 r % Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address I/ /,, JOB ADDRESS LLB"/` �) pj !' _ 'd�i6 /ct ��"/ LOT# � SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT 0 SIGN Q Q DEMOLISH B INSTALL a REPAIR PROPOSED USE Q SFR 0 COMM �� OTHER j.; TYPE OF CONSTRUCTION /lBLLLOCCjK� Qq � �, FRAME n� STEEL Q. DESCRIPTION OF WORK !!"��GGL/ /�//iv Im UL 07) � 'Jt t yYZJ BUILDING SIZE ) /+ SQ FOOTAGE oC J HEIGHT =BUILDING $�/�j/f/j/�, O/5 VALUATION OF.TOTAL CONSTRUCTION ELECTRICAL $ �[� '�`� AMP SERVICE Q PROGRESS ENERGY 0 W.R.E.C. PLUMBING $� �7/ /'� /� / (�© =MECHANICAL $ q6, /1O VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY OTHER FINISHED FLOOR ELEVATIONS ,D FLOOD ZONE AREA =YES NO BUILDER COMPANY II SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address License# G n OTHER COMPANY V'/U�� l�tl�L� �C ✓�G�/)G� �G� �> ��/ SIGNATURE REGISTERED Y/N FEE CURREN Y1//�N Address (��� �, License# — /! all alQl1IE2illa1.112avalstaIItlils its 1122 Vaaas111113:19 ■ IIIIIllltlFlil[ I21E31111119.92929 111-1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction: Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: . Fill out application completely. Owner&Contractor sign back of application, notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) ** Agent(forthe contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same . OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 6. . D Q r. Single Family Dwelling Plan Review Comments 1. FF.E shall be a minimum of 8" above the road elevation and an engineered site plan. I Lots shall be graded t . cor'' ly with R401.3 of the F.B.C. 3. Compaction test required if 24"or more of fill-dirt is brought in at any one.place. 4: Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides_ of driveway thru the sidewalk shall have expansion material. 6: All setbacks shall be-met. -7: All property markers shall be uncovered,and marked at time of first inspection. 8: All A:D.A.requirements shall be met: 9.. No electric,.plumbing; mechanical, or framing shall.be covered without an inspection and approval first. 10-. All Garages all comply with section R302.6 of the F.B-C. (Fire Separation): 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water-heater-s shall comply with section P607.3 of the F.B.C: 13. Foundation supports for A/C units shall be raised at least 3" above finislied grade. M1308.1 14. Return air in all bedrooms: F.B.C. M1620,4 1.5. Smoke detectors are to be installed in accordance with R3111 of.the F.B.C. 16. A11 glazing requirements are to be in accordance with R308:4-of the F.B.-C.; 17. All means.of egress are to be in accordance'with R311 of the F.B.C: 18. "Green gypsum,board" shall riot be used as a backer,in showers or tubs. R702.4.2 F.B.C. 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will bete 'uired in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit: This includes all underground plumbing and electric., 22. All 2016 N.E.C. Codes will be enforced: 23. Tamper- Resistant Receptacles in accordance with 406.11 of the pi N.E:C 24. In accordance with the Land Development Code,lots shall be sodded before final at_least 10 feet around the structure. 25. R403.5.Mof.water pipe insulation. Insulation for hot water pipe With a"minimum thermal resistance (R-value) of R-3 shall.be applied to the following: . - Piping.V. inch (19.1 mm)and larger in nominal diameter. Piping.serving more than one dwelling unit: Piping 10 catiad outside the conditioned space, Piping from the water heater to a distribution manifold: Piping.located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower dloor test shall be provided before C.O: 26.A copy of the energy cacls shall be with permit at all times 2Z Copy of Fnal insulation report shall be provided with permit before rnaL 28. No fence, pool or screen enclosure .is issued with ahis permit F.F.E.-Finished Floor Elevation RB.C-.=Florida Building Code 6d Edition R.O.W.-Right of Way A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code(2016) --- -- ---- Vfiy VI 1-1--P 1y111111A r-rrii111L1-%IJp1m..QUVri 1 MuIJ-/uV-uVGI Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for,compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor,is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Lidnnsing Section at 727-847-8009. Furthermore, if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sigh as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07.and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood thatTransportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more, I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law'—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to,commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to'issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND AIN FINANCING, CONSULT WITH YQJJR LEND - TORNEY BEFORE RECORDING YOU :....... ..... FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subs rib d and sworn do(or a be or me this Subscribe d sworn o.(or a ed)befo me this 4dKby �4�7/�lJl� �L%�i/��lc _2 by �7/)07� ' �d�GU/I�l� h(LLs/are pers_nagl +�^gyp or has/have produced Who is/are personally.kin-own to me or has/have produced as identification. as identification. 0 Notary Public I Notary Public Comm's i n No. Commi si No. y/Ok/ �,i�Z 7f Nam6 of Notary typed,printed or stamped Name of Notary typed,printed or stamped PATRICIA BURCHETT =(a !AUU RCHETiMy COMMISSION#GG365171 #GG365171EXPIRES:AUG 13,2023 13,2023Bonded through 1st State Insurance State Insurance : PASCO COUNTY, FLORIDA Permit No. 7 a / dd// Date Permitted — Za I Builder Name/Owner Name A/4_l` K" Control#' County Parcel No. (� 0 2-1 D/ 2?)06d C)Q 7®. SubDiv: Otis 96-0 Address/Location d c�� !r�� uk ClassificationlType;of Usq eW TRANSPORTATION IMPACT FEE Rate: Sq.R Unit: Exempt ❑Yes ❑•No How Determined Impact Fee Amount $. Zone No. TAZ: SCHOOL IMPACT FEE ® Account (056) Single-Family Detached House Amount $ (057) Mobile,Home (058)1 Other Residential 23)1 Collection Fee Exempt d Yes- .❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $.76,9•C% a Exempt ❑Yes 0 No How Determined LIBRARY FEE Land A&eunf Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amoun .RESOURCE FEE ERU TOTAL AMOUNT i Prepared By Checked By NO CERTIFICATE OF:000UPANCY WILL BE IS OR FINAL INSPECTION PERFORMED UNTIL'THE'TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE•OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence;but simply recelpt;of a copy of-this form;placing the building permlt owner on notice.of this assessment and the conditions of payment-for same. DATE RECEIVED BY RECEIPT NO. DATE BY C:ITY OF ZEPHYRHILL► "City of Pure Water" 5335 Eighth Street-Zephyrhills,Florida 33542=4312 (813)780-0000 a Fax (813) 780-0005 GENE WHITFIELD Mayor June 13,2018 CITY COUNCIL Mr. David Waronker 1420 Celebration Blvd., Suite 200 LANCE A.SMITH Celebration,FL 34747 Council President Dear Mr.Waronker, KENNEM M.BURGESS,JR. ; Vice President City of Zephyrhills Ordinance 1003-08, Section 12, Paragraph 5, provides that planned -unit developments (PUD) approved prior to September 30, 1988. are CHARLES E.PROCTOR exempt from paying transportation impact fees unless amended to 'permit additional development that would generate traffic. W.ALAN KNIGHT The Silver Oaks PUD-was approved on its third and final reading on January l 1, JODI WILKESON 1988, and therefore is exempt from paying transportation impact fees as stipulated in Ordinance 100308 provided the original permitted number of dwelling units remains the same.According to Todd Vande Berg, city planner,those numbers within the Silver Oaks PUD have remained constant. STEVEN F.SPINA City Manager Therefore, the Oaks at Pasco is exempt from paying these fees:A copy of LORI L.HILLMAN Ordinance 1003-08 is provided for your information.The exemption and credits City Clerk,CMC section is located on page 10. MATrHEW E.MAGGARD Sincerely, City Attorney Steven F, Spina,PhD City Manager cc: Todd Vande Berg, City Planner Bill Burgess,Building Official Matthew E. Maggard, City Attorney PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 51, OAKS OF PASCO AS RECORDED IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 5,750 SQ. FT. LIVING AREA = 1,850 SQ. FT. GARAGE = 524 SQ. FT. ENTRY = 21 SQ. FT. LANAI = 154 SQ. FT. Curve table PATIO = 0 SQ. FT. DRIVEWAY = 328 SQ. FT. Curve R Length Radius Delta Chord Bearing Chord A/C PAD = 9 SQ. FT. CI 6.53' 55.00' 6'48'13- N07'41'50-W 6,53' WALKWAY = 41 SQ. FT. a IMPERVIOUS = 51% 2927 SQ. FT. IX Line Table . SOD = 2,823 SQ. FT. i Line 9 Direction Length OFF LOT CALCULATIONS 1" = 30'. RIGHT OF WAY = 396 SQ. FT. GRAPHIC SCALE L1 N04-17-44-W 43.48' DRIVE APRON = 57 SQ. FT. PUBLIC S/W = 250 SQ. FT. 0 15 30 SOD = 89 SQ. FT. TOTALS AREA = 6,146 SQ. FT. DRIVEWAY = 385 SQ. FT. SIDEWALK = 291 SQ. FT.- SOD = 2,912 SQ. FT... � I O \ cn N \ 90.2p 8850 \ 9�5 (NON-RADIAL)n 115.J9' $' N85'4216 E o 30.5 o A/C C� 64.6 20.5' 70.00' Vp j O ::."-:- ' PROPOSED QO m z ca ..a r`j••:;A. COVERED C1 0 0 0 I I:" ': .1 TRY HIGHGATE- o CJt ITl D x :..,is 4' GARAGE EXT. o iA rnh --II o_ D A o i 0 . 9.3' FINISHED FLOOR EX. w 0 i1 �Z r 20.5 5.0'N ELEVATION=91um 9.0, ;I p Lp m0 m O rn� fm I 5.3' 6.0' cat vo o O�� '•:.15.0`'.: J 24.5t� v�� m 51.0' � c 5>0 AI - 24 b .. N - -- Z 8888 S85'4216 W �� 115.00' 099� e�yh q Cl J_ W m I ON I O G8 1 -� �O m LTI I O PREPARED FOR: 1 6a e GZ T, ra�rrr J BUILDING SETBACKS FRONT: 20' REAR: 10' SIDE: 5' SIDE STREET: 15' LEGEND: NOTES: — BUILDING SETBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVATURE 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED — CENTERLINE PT PONT OF TANGENCY ON THE 'APPROVED ENGINEERING PLANS PREPARED _ _ RIGHT OF WAY LINE RP RADIUS POINT BY CORNELISON ENGINEERING & DESIGN INC. PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCP PERMANENT CONTROL POINT DATUM. TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES Sx•;-;"i; CONCRETE (P) PER PLAT) CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (PB�(C PLAT BOOK THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGs PAGES OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING s/w SIDEWALK SO. FT. SQUARE FEET DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM SSE SANITARY SEWER EASEMENT THIS IS NOT A SURVEY DE DRANAGE EASEMENT THIS IS A PLOT PLAN.ONLY UE UTILITY EASEMENT SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO289F, DATED 1. THE SURVEYOR HAS NOT ABSTRACTED THE 19/26/2014, AND FOUND THE SUBJECT PROPERTY APPEARS TO LIE IN LAND SHOWN HEREON FOR EASEMENTS, RIGHT ZONE'AV, DENOTES AREAS DETERMINED TO BE SPECIAL FLOOD HAZARD OF WAY, RESTRICTIONS OF RECORD WHICH AREAS SUBJECT TO INUNDATION BY THE 1S ANNUAL CHANCE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND. EVENT, BASE FLOOD ELEVATIONS DETERMINED TO BE 88.5'. THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. 2 NO UNDERGROUND IMPROVEMENTS HAVE BEEN PLEASE CONTACT THE LOCAL F.E.M.A. .M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF A5M 3. NOT VALID WITHOUT THE AUTHENTIC BRADFORD WOODS DRIVE BEING N04'17'44'W, PER.PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: AMERICAN SURVEYOR AND MAPPER. (FIELD DATE:) - S U F:;,\/F-Y I N G SCALE: ycYiu,ao Dig:-US,igned bi Jam sVlBoleman 0dando, 1' 30 FEET � DN:SUS,rt=Florida,I=Odando, 4& MAPPING INC. `'°"�+ o AMERICAN SURVEYING& APPROVED BY: JBMAPPING,INC,cn=JamesIN �- '^-mow.•, CERTIFICATION OF AUTHORIZATION NUMBER LB//6393 g t Boleman FOR 3191 MAGUIRE BOULEVARD, SUITE 200 4`'tij r -email=iboleman@asmcorporate.comME JOB NO. 191105 LOT 51 ORLANDO, FLORIDA 32803 mmmni mm Date:2020.08.0509.4600-04'00' FIR (407) 426-7979 DRAWN BY: RMB PLOT PLAN OB 04 2020 JG WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE