Loading...
HomeMy WebLinkAbout20-726 m City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BGR-000726-2020 Phone: (813)780-0020 �. Fax: (813)780-0021 Issue Date: 10/08/2020 Permit Type: Building General (Residential) Property Number Street Address 32 25 21 0100 01700 0050 7130 Boxer Round PI Owner Information Permit Information Contractor Information Name: EFRAIN&ISABELLE ZENON Permit Type:Building General(Residential) Contractor:VIVINT SOLAR DEVELOPEF Class of Work:Electric Service Replacement/ LLC Address: 7130 Boxer Round PI Building Valuation:$3,003.00 ZEPHYRHILLS,FL 33542 Electrical Valuation:$12,012.00 Phone: Mechanical Valuation: Plumbing Valuation: Total Valuation:$15,015.00 Total Fees:$232.62 Amount Paid:$232.62 Date Paid:10/8/2020 11:27:10AM Project Description INSTALLATION ROOF MOUNT PHOTOVOLTAIC SOLAR Application Fees Building Permit Fee $55.02 Building Valuation Fee $27.51 Electrical Permit Fee $100.06 Electrical Plan Review Fee $50.03 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. LA IZL C91 - 0 ONTRACTO SIGNATU PE IT OFFICE PERMIT EXPIRE IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-7aa­o020 City of Zephyrhills Permit Application Fax-813480-0021 Building Department Date Received Phone Contact for Permilding I(S Owners Name �ryOwner Phone Number [VQLL_ j3)2q L4 owniees Address 136X_F'Q PiIIUM �p Owner Phone Number Fee Simple'rdieholder Name Owner Phone blumber Fee Simple Titleholder Address JOB ADDRESS 5019 POKER _00AIL) Pt -1,16PHYPURA-� LOT# SUBDIVISION F_ PARCELID#1'3;-'-2S-2-1- 0100 -0170,0 - 00,SD (..N.FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTRR R ADDIALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE = SFR Q 'COMM = OTHER TYPE OF CON=ucnor4 = BLOCK FRAME STEEL DESCRIPTION OF WORK rg<rp u-nue N of- golo r-H o wra P tj 6a)vo LvqiE7 S uqc BUILDING SIZE SO FOOTAGE "EIGHT BUILDING S 003 VALUATION OF TOTAL CONSTRUCTION rl_�ELEGTRICAL I's 12,012 AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C. =PLUMBING 1$ 5 r7MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION i =GAS = ROOFING = SPECIALTY = OTHER FLOOD ZONE AREA AYES NO Fl NISHED FLOOR ELEVATIONS - - - - . . . . . .. .. . . . . . . . . . . . . . . . . . . . . . BUILDER COMPANY IVE 1jQ\14 '�O LA k bCJ1QAPrA9. SIGNATURE REGISTERED ICY/ N FEECURRE!, ':[< At IAI f1l)AM&IIAA b2m# ? NLAP 1�I 1_)01 N J LAddess License# Qlo-7 l b ELECTRICIAN COMPANY =VVL3LIC SIGNATURE REGISTERED Y/ N CURRE% Y/N I Add. License#1 PLUMBER COMPANY SIGNATURE REGISTERED YIN IFFECURREN Y/N Address I License# MECHANICAL COMPANY = SIGNATURE REGISTERED Y/ N FEEcuRRa I Y/N Address License# OTHER COMPANY = SIGNATURE REGISTERED Y/N I FEE CURREN L_XZN J Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms:R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster,Site Work Permit for subdivisionsfiarge,projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Farms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all now projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Directions Fig out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power ofAttomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fencei(Plot/Survey/Footage) Driveways-Not over Counter if on public madways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILMES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy,"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that 1, the applicant, have been provided with a copy of the "Florida Construction lien Law—Homeowner's Protection Guider prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant Is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. , CONTRACTOWSIOWNEWS AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all taws regulating construction, County and City codes, zoning regulations, and land development regulations In the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads,Wetland Areas and Environmentally Sensitive Lands,WaterMastewater Treatment. - Southwest Florida Water Management District-Wells. Cypress Bayheads, Weiland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement - Federal Aviation Authority-Runways. : I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone'W unless expressly permitted. - If the fill material is to be used in Flood Zone W, it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used In Road Zone"K in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill Will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing,signs,wells, pools,air conditioning,gas,or other Installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit Issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and Will demonstrate justifiable cause for the extension. If work ceases for: ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER. YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDS R OR AN ATTORNEY BEFORE RECORDING YOUR NO ICEOF COMMENCEMENT. FLORIDA JURAT(F.S OWNER OR AGENT CONTRACTOR S b 3r affirmed)40 0 Subscribed and swam to(or affirmed)before me this A AL rl I i IM7by Wh6Wafapef499HZXno%1 It -.7have produced lin to me or has Who Is/are personally known to me or hasilhave,produced as identification. as identification. ANotary Public Notary Public. Commission No. Commission No. Name,of No bi S"te of Name of Notary typed,printed or stamped an Put" NOWY Put"Sste ol r tJames Quillen H Q My Commissori HH 012 Ey 4J Ex Ow2w= 'p'� ei Pies 125127 Docuaign Envelope ID: � ����3 �� 1� 1G�0VVAs�onB�d. ��i ���� ��� �������� Lehi, LIT 84U43 Structural Group J. Matthew Walsh, PE Kirk M.Nelson, SE Samuel Brown, PE- Civil Director of Engineering Structural Engineering Structural Engineering Jannes.waish@vivincso/ar.cowr kirk.oe/son@vivin*solaccmn, aaoobmomm@,ivintsolancmm September 1O.2O2O ` Re: Structural Engineering Services Zenon Structure 7130 Boxer Round P|, ZephyrhiUs, FL S'6437893; FL-01 Tn Whom b May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced structure: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the aiza, opacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and vorfiooUonforms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above informction, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related bm our review and . evaluation: A. Description ofStructure: The existing structure has typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Southern Pine#2 or bettor with standard construction components. The designed areas of the home consist of the following framing methods: ° Roof Section: Prefabricated trusses ot24'' oncenter. Survey photos indicate that there was free access ho verify the framing size and spacing. B. Loading Criteria 14.GGPSF= Dead Load (noofing/framing) (solar panels/mounting hardware) 17.G8PSF=Total Dead Load (based nn local requirements) Wind speed of 145 mph (based on Exposure Category D-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C. Solar Panel Anchorage 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. If, during solar panel inoto||nUon, the roof framing members appear unstable or deflect non-uniform|y, our office should be notified before proceeding with the installation. ° EooFauten Solar Installation W;onuai, which can be found on the EooFastan Solar woboiba . (wwmv.eoofostanoo|er.com). 2. The solar panels are 11/2" Mhick Atno time will the panels be mounted higher than 10^ above the existing surface of the roof. Page Yofz ��������z� ,���� �� � nxmwmmoa@� ��»�v��� � DocuSign Envelope ID:398475A4-9752-4AD3-BBF7-AA6C43DDOAF4 3. The following mounting types shall be used. Please refer to the mounting details for the associated mounting method requirements. Based on our evaluation, the uplift demand is less than the maximum allowable per mount and therefore is adequate. • Rock-It: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) of timber construction specifications for Southern Pine is 235 Ibs/inch penetration. 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2017 FBC 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10. These spacing requirements apply to all mount types indicated above. The following values have been verified by in-house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections should be staggered, where possible, to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 48 48 48 48 48 48 Max Uplift Load Ibs 338 270 250 579 231 107 D. Summary Based on the above evaluation, with appropriate panel anchors being utilized, the roof system designed on will adequately support the additional loading imposed,by the solar panels, if installed correctly. This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida Building Code- Residential 6th Edition, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. Regards, -1 NE J. Matthew Walsh, PE N 84� FL License No. 84923 CDocuSigned by: _— �'b�✓r� `/L.�� STATE OF 7AEE820514FE4D2... �%O� • F ��� Matthew Walsh ® September 10,2020 8:22 AM MDT //0NA 1,0�\\\�\ This item has been electronically signed and sealed by Matt Walsh using 09/10/2020 a Digital signature and date. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 2 of 2 v,uvPH �. o a DocuSign Envelope ID:398475A4-9752-4AD3-BBF7-AA6C43DDOAF4 1300 YJ Ashton Blvd. v i-il i n a r Lehi, UT 84043 Structural Group J.Matthew Walsh,PE Kirk M. Nelson,SE Samuel Brown,PE-Civil Dkedor of Engineering Structural Engineering Structural EnWneedng jmes.waish@vivintsolar.com kirtnelson@vMnisolar.com sarn.brown@v!Wnisolar.com Structural Design Criteria Project Address Date: September 10,2020 Zenon Residence 7130 Boxer Round PI Zephyrhills,FL S-6437893 Residence v- Risk Category 11 Roof Area 2691 sf N? Upper Floor Area 0 sf Number of Stories I STATE OF zz Mean Roof height 15 ft 0. X% Upper Floor height 0 ft �P' tOR10?---" Location Parameters /ONAL Latitude 28.261111 141441malO Longitude -82.226111 Site Class D(Default) Risk Category it Existing Gravity Parameters Roof Dead Load 5 psf Composite Shingle 2 psf 3/4"Plywood Sheathing 2 psf Roof Framing @ 24 in.o.c. 3 psf Ceiling,Mechanical,Electrical 2 psf Miscellaneous 15 psf TOTAL Roof Live Load 20 psf' Wall Dead Load Ground Snow Load 0 psf 8 ft Wall Height Flat Roof Snow Load 0 psf 300 ft Wall Length 12 psf Wall Weight New Gravity Parameters Roof Dead Load 3.00 psf Solar Panel Weight Roof Live Load with Solar Panels 0 psf Roof Slope Factor 0.7 Roof Slope Factor(ASCE 7-10 Fig.7-2b) Roof Snow Load 0 psf ASCE 7-10 Eq.7.4-1 Seismic Parameters SS = 0.067 g 0.2 see Spectral Response Acceleration S, = 0.034 g 1.0 see Spectral Response Acceleration Fa= 1.600 g Site Coefficient from ASCE 7-10,Table 11.4-1 Fv= 2.400 Site Coefficient from ASCE 7-10,Table 11.4-2 SDS = 0.071 - Short Period Design Spectral Acceleration SDI = 0.054 g I Second Period Design Spectral Acceleration Page 1 of 3 Lv,,ivLff in To . sto�d a DocuSign Envelope ID:398475A4-9752-4AD3-BBF7-AA6C43DDOAF4 Wind Parameters Wind Speed 145 mph Exposure Category D Roof Angle, 0 27.0 deg Product Information No.of Panels 21 Weight 3.00 psf including mounting system Installed Area 381.2 ft? No.of Connectors 28 Total Existing Roof Load=Roof Dead Load+(Roof Live Load or Snow)x Spacing 69.32 plf Total New Roof Load=Roof Dead Load+Added Dead Load+(Roof Live Load or Snow)x Spacing) 35.32 plf Change in Demand=(Total New Load-Existing Load)/Existing Load -49.05% Total New Gravity Loads aie less than Existing Loads. OK 2015 IEBC Section 707.2 states: "Where addition or replacement of roofing or replacement of equipment results in additional dead loads,structural components supporting such reroofing or equipment shall comply with the gravity load requirements of the International Building Code. EXCEPTION 1.Structural elements where the additional dead load from the roofing or equipment does not increase the force in the element by more than 5 percent." 2015 IRC Section AJ501.4 states: "The minimum design loads for the structure shall be the loads applicable at the time the building was constructed,provided that a dangerous condition is not created.Structural elements that are uncovered during the course of the alteration and that are found to be unsound or dangerous shall be made to comply with the applicable requirements of this code." 2017 FBC Section AJ104.1 states: "Detached one-or two-family dwellings that are not irregular buildings under Section R301.2.2.2.5 and are not undergoing an extensive reconstruction shall not be required to be evaluated." Page 2 of 3 vnn nt, S- '1 # DocuSign Envelope ID:398475A4-9752-4AD3-BBF7-AA6C43DDOAF4 Wind Uplift Simplified Procedure for Components and Cladding ASCE 7-10,Section 30.5 V= 145 mph Basic Wind Speed Exposure D ASCE 7-10,Section 26.7 = 1.47 Adjustment Factor for building height,ASCE 7-10,Figure 30.5-1 Kit= 1 Topographic Factor,ASCE 7-10,Section 26.8.2 Roof 0= 27.0 deg sanchor= 48 in Horizontal spacing of roof anchors Attib= 22.31 sf Panel Area tributary to,each roof anchor r Pnet30 Net Wind Design Pressure,ASCE 7-10,Figure 30.5-1 Roof Zone Zone 1 Zone 2 Zone 3 As shown in ASCE 7-10,Figure 30.5-1 31.5 psf 49.1 psf 89.3 psf Pnet=AK41?net3o= Design Wind Uplift Pressure,ASCE 7-10,Equation 30.5-1 Zone 1 Zone 2 Zone 3 46 psf 72 psf 131 psf Pnet= 16 psf Minimum Design Wind Pressure,ASCE 7-10, Section 30.2.2 Use 46 psf Use 72 psf Use 131 psf Connection to Existing Roof Framing F.S.= 1 Additional Factor of Safety applied to withdrawal force,if desired DLpanei= 3.00 psf Zone 1 Zone 2 Zone 3 Wuplift= 46 psf 72 psf 131 psf Abib= 22.3 sq.ft 11.2 sq.ft 5.6 sq.ft Pig=F.S.x Attih x(0.613-0.6W) Withdrawal force for each roof anchor Zone 1 Zone 2 Zone 3 -578.7lbs -231.51bs -107.3lbs Connection Capacity db= 5/16 in Lag Screw diameter Dpen= ' 2.50 in Lag Screw penetration into existing framing member Southern Pine Species of wood framing CD= 1.6 Load Duration Factor;for Wind Loading,NDS Table 2.3.2 Ct= 0.7 Temperature Factor,NDS Table 10.3.4 W= 235 lb/in Withdrawal Capacity NDS Equation 12.2-1 W'=CD x Ct x W= 263 lb/in Adjusted withdrawal value Pattow=Dpen x W,= 657 lbs Based on penetration depth Zone 1 Zone 2 Zone 3 DEMAND= 579 lbs 231 lbs 107 lbs Max Load=0.881 OK CAPACITY= 6571bs 657 lbs 657 lbs _ r Page 3of3 vivi n , o2- � t 01arCanadianS l Vow �,•,. yi�w��;4x5sY. , density MONO ALC_�CAC,iC 9 320 iN r 34013�3®133513401\AS CS1w"320132 MOREPOWER ,sorption warranty on materials P area, the light absorp o� . Maximize anted product* zfl 16 a module efficiency uP to Z0.16 5 -.,5' enhanced workmanship ay,).. Low temperature P erature coefficient(Pm � linear power output warranty* tementi .. 2� arrantYsta ears � lted W ................... tolerance to the applicable Can Solar I.irtr ....• getter shadingAcmraing ......................... YSTEM CERTIFICATES MANAGEMENT`' a entsystem ertsystem man gem enagem heath&safety IS0 900 1 201s 1 Quality env.ronmental m ational MORE RELIASLE ISO A4001:2015!St!dtednational standards for occo 0HSA518001:2007 Lower internal current,ature pROI)UCT CERTIFICATES* us Ptoridal lower hot spot temp )CE t MCS usi t FSEc 61730:VDE ante:CeC listed t It region, IEC 61215 t IEC edorm .n sm UL 170311EC 61215 P VDE 1 IEC 62716:VDE limited 61701 ED2: Cell crack risk eliability CSA t IEc e module r UL 1103: Q ��enhance th Take-e Nay �°.� "Za}CEBT lease co" the t0 5400 P a, C " arkets.P to the snow load UP * ovc S�•,.( uiremenvies ecificc rtrftcatesapPltwble Heavy 2400Pa c certificationrtai used. re diff pe sales repretihe p�oduets aye to be h �c�r wind loaduPt° ,stherenad.an5 nwelch ........................... """ rovidin9 hfg Pro ua .............. muted t0 P services to productsmthe —S LARINC•is Cotr1 tions and Uauty pOIAN 50 system solo tier for q CAN roducts•solar y module SUPP er Insight quality solar P d the world•. Module Custom aroun do in IHS and manufa e World cler e to mancetprlPv project developer a and e es W th over 38 SW deployed around th Survey-p s a lea of solar mod ............. since 200'l• ..•• olar.com ................. °rt@canadians at.adon Manua.. 1 K 1 E6 'Canada•`4`NN•canadiansolar. com,supP fer to lost ................. ' adon.Pease re ............. .................... t for detail inform C. CAhiAO.`....... ven e West.Guelph,Ontario N N SpLA 545 Speedvale A ENGINEERING DRAWING(mm) CS1 H-330MS/I-V CURVES Rear View Frame Cross Section A-A A A 12 12 - ---------- -- ------------------- 35 31, 11 --------------- ------------------------------ 10 -7- .. ....---------------------- 9. 9 ---------------------- -------- 8-1-9 M 7 7 6 6 -------- 5 5 --- --------------- 4- 4 12 _ itMounting Hole 3 - ------ 3 2 2 --- ----- ----------------- 0 V o- 5 10 15 20 25 30 35 40 45 50 5 10 15 20 25 30 35 40 45 50 1000 W/m' 5-C N A L A �1 1 25°C M L! 6,00 1�0 WW/.' 45°C N 944 400 WW 65°C M 992 200 WW ELECTRICAL DATA I STC- MECHANICAL DATA CS1 H 320MS 325MS 330MS 335MS 340MS Specification Data Nominal Max.Power(Pmax) 320 W 325 W 330 W 335 W 340 W Cell Type Mono-crystalline Opt.Operating Voltage(Vmp) 36.2 V 36.6 V 37.0 V 37.4 V 37.8 V Dimensions 1700 x992 x35 mm Opt.Operating Current(Imp) 8.85 A 8.88 A 8.92 A 8.96 A 9.00 A (66.9 x 39.1 x 1.38 in) Open Circuit Voltage(Voc) 44.0 V 44.1 V 44.2 V 44.3 V 44.5 V Weight 19.2 kg(42.3 lbs) Short Circuit Current(Isc) 9.41 A 9.45 A 9.49 A 9.53 A 9.57 A Front Cover 3.2 mm tempered glass Module Efficiency 18.98% 19.27% 19.57% 19.86% 20.16% Frame Anodized aluminium alloy Operating Temperature -40*C-+851C ]-Box IP68,3 bypass diodes Max.System Voltage 1 OOOV(IEC/U Q Cable 4.0 MM2(1EQ,12 AWG(UL) TYPE 1(UL 1703)or Cable Length 1350 mm(53.1 in) Module Fire Performance CLASS C(IEC 61730) (Including Connector) Max.Series Fuse Rating 15A Connector T4 series or H4 UTX or MC4-EV02 Per Pallet 30 pieces Application Classification Class A Per Container(40'HQ) 780 pieces Power Tolerance 0­5W *Under Standard Test Conditions(STC)of irradiance of 1000 W/mz,spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA I NMOT- TEMPERATURE CHARACTERISTICS CS1 H 320MS 325MS 330MS 335MS 340MS Specification Data Nominal Max.Power(Pmax) 236 W 240 W 243 W 247 W 251 W Temperature Coefficient(Pmax) -0.37%/'C Opt.Operating Voltage(Vmp) 33.4 V 33.7 V 34.1 V 34.5 V 34.8 V Temperature Coefficient(Voc) -0.29%/'C Opt.Operating Current(Imp) 7.07 A 7.11 A 7.14 A 7.17 A 7.20 A Temperature Coefficient(Isc) 0.05%I IC Open Circuit Voltage(Voc) 41.0 V 41.1 V 41.2 V 41.3 V 41.5 V Nominal Module Operating Temperature 44±3 IC Short Circuit Current(Isc) 7.60 A 7.63 A 7.66 A 7.70 A 7.73 A *Under Nominal Module Operating Temperature(N M CIT),irradiance of 800 W/M2.spe ctru m AM 1.5,ambient temperature 20°C,wind speed 1 m/s. PARTNER SECTION ......................................................................................................... The specifications and key features contained in this clatasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement.Canadian Solar Inc.reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. ......................................................................................................... .............................................................I................................................................................................................................................................................. CANADIAN SOLAR INC. 545 Speedvale Avenue West,Guelph,Ontario N1 K 1 E6,Canada,www.canadiansolar.com,support@canadiansolar.com December 2019.All rights reserved,PV Module Product DatasheetV5.583JN i gInverter i. Sin le Phase Z with H. D-Wave'' Techndlogy m for North America SE3000H-US/ SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US SE10000H-US SE11:400H-UUS / / m solar 3�C' Yai^vov� 9 solar, 1' Y C1 I •••• • • 6 • I - i I Optimized installation with HD-Wave technology Specifically designed to work with ® Extremely small power optimizers 0 Record-breaking efficiency / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation Integrated arc fault protection and rapid shutdown for ® Optional: Revenue grade data,ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) UL1741 SA certified,for CPUC Rule 21 grid compliance solaredge.com solar • ® Z / Single Phase Inverter with HD-Wave Techn®l®gy for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-U.S/ SE760OH-US / SE1000OH-US / SE1140OH-US SE300OH-US811 00O .00O .11 1111 40O OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 1600 10000 114DO @ 240V VA 3300 @ 208V I 5000 @ 208V 10000 @ 208V 3800 @ 240V 6000 @ 240V 1 11400 @ 240V Maximum AC Power Output 3000 3300 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA AC Output Voltage Min.-Nom.-Max V (211-240-264) Vac AC Output Voltage Min.-Nom.-Marc. Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.511- Hz Maximum Continuous Output 12.5 16 21 I 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 - 24 - i 48.5- A Current @208V GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VII) 8.5 10.5 13.5 16.5 20 27 30.5 I Adc Maximum Input Current @208VIa - I 9 13.5 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 50042 Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency gg 99_@240V 98.5 @ 208V Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional"[ Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 1'Maximum/14-6 AWG 1'Maximum/14-4 AWG DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1°Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch 17 7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ (HxWxD) mm Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -13 to+140/-25 to 6011(-40'F/-40°C option)Isl 'F/-C Protection Rating NEMA 4X(Inverter with Safety Switch) °i For other regional settings please contact SolarEdge support A higher current source may be used,the inverter will limit its input current to the values stated Revenue grade inverter P/N.SExmxH-US000NNC2 "For power de-rating information refer to:https.//,w ..solaredge com/sites/detault/files/se-temperature-derating-note-na.pdf -40 version P/N SExxxxH-US000NNU4 '0 SolarEdge Technologies.Inc All rights reserved SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SalarEdge Technologies,Inc.All ®®� other trademarks mentioned herein are trademarks of their respective owners.Date:032019/`/Ol/ENG NAM.Subject to change w R without notice.