HomeMy WebLinkAbout20-752 Q
City of Zephyrhills PERMIT NUMBER
5335 Eighth Street
Zephyrhills, FL 33542 BNR-000762-2020
Phone: (813)780-0020
+` Fax: (813)780-0021 1 Issue Date: 10/22/2020
Permit Type: Building New (Residential)
Property Number Street Address
32 25 21 0100 01800 0140 135659 Stella Vast Drive
Owner Information Permit Information Contractor Information
Name: D R HORTON Permit Type:Building New(Residential) Contractor: D R HORTON INC
Class of Work:SFR Construct
Address: 12602 Telecom Dr Building Valuation:$107,000.00
TAMPA,FL 33637 Electrical Valuation:$6,800.00 /►
Phone: (813)549-1968 Mechanical Valuation:$4,800.00
Plumbing Valuation:$7,200.00
Total Valuation:$125,800.00
Total Fees:$14,609.69 �� rrr✓✓✓
Amount Paid:$14,609.69
Date Paid:10/22/2020 1:56:30PM
Project Description
CONSTRUCT SINGLE FAMILY 2,238 SQ FT-SILVERADO
Application Fees
Address Fee $30.00 Building Permit Fee $565.00
Mechanical Plan Review Fee $32.00 Public Safety Impact Fee-Police $254.00
Plumbing Permit Fee $76.00 Transportation Impact Fee $3,595.68
Park Impact Fee-Single Family/Townhome $769.56 Electrical Plan Review Fee $37.00
Driveway Fee $45.00 Transportation Impact Fee-City $36.32
Building Plan Review Fee $282.50 Public Safety Impact Fee-Admin $26.35
Plumbing Plan Review Fee $38.00 Electrical Permit Fee $74.00
SIF 1 percent Fee $83.28 School Impact Fee $8,328.00
Mechanical Permit Fee $64.00 Public Safety Impact Fee-Fire $273.00
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATU E PEf IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
city OfZenhyrh\l\8 Permit Application Fax-8 8-78O-0021
^ , Building Department
Phone Contact for Permitting
Owner's Name Owner Phone Number
Owner's Address le co no. 1K_.,_T_a-n&. 3�L Owner Phone Number
'Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
SUBDIVISION PARCEL ID#F_3
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTRR ADD/ALT SIGN DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
BUILDING SIZE SQ FOOTAGE HEIGHT
JOB ADDRESS ILOT#
[--�BD|L0Ng
�--� VALUATION OFTOTAL CONSTRUCTION=ELEOTRICAL AMP SERVICE �—1 PRVGRESSENERGY miR.s.C.
=pLUMBUNG
=MECHANICA VALUATION OF MECHANICAL INSTALLATION
�--� ���'8AG R�QBMn �-� � �PE0�[[� F---1 OTHBR
�_� �_z
FINISHED FLOOR ELEVATIONS I q()7FLOOD ZONE AREA =YEG NO "
BUILDER COMPANY
SIGNATURE nEG/arsnso psI�CURne��
Add,ess Uoonan#
` ELECTRICIAN COMPANY
SIGNATURE nEo/oTsnso Y I N i ^ FEE CORnEN-L
Address 3± jbhlas License#
PLUMBER
SIGNATURE
Auummn
MECHANICAL COMPANY Pr0qtvis'1Q-e LEE
SIGNATURE
Address Ummae#
OTHER COMPANY
SIGNATURE
FEE CURREIN ____'
Address Unonua#
nnuonxxuumu � xxu � mxoVx � �^oxoxV �� xnV � xxnuVmxx0UK � xuuvmmoxmn � xnxmmUxo8m
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
' -Minimum ten(1o)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpsher;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(1O)working days after submittal date. Required onoKn.Construction Plans,G\onnvwaer Plans v/Silt Fence installed,
Sanitary Facilities&1dumdoter.Site Work Permit for all new p' oots./Alcommoncia|requinemontsmuatmnetoump|ianco
SIGN PERMIT Attach(2)sets of Engineered piBns.
°=°PR0PERrY SURVEY required for all NEW construction. '
Fill out application completely.
Owner 8 Contractor sign back of application,notarized
|f over*oaoo'a Notice p,Commencement isrequired. (/VG upgrades over$75on)
� Agent(for the contractor)or Power of Attorne�(for the owner)would be someone With notarized letterfrom owner authorizing'same
OVER THE COUNTER PERMITTING (copy of contract required)
Remufsifshingles Sewers Service Upgrades A/C Fenmao(P|oUSumey/Fno(oge) , ^
Driveways-Not over Counter ifnn public modoayn,noedsROW
'. .
~~
��& '
NOTICE 0F DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"daad reotrictioms" '
which may ba more restrictive than County regulations. The undersigned neeumoareaponsib||ityforoonnpUancovvithany
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as.required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing,Section at 727-847-
8009. Furthernnoro, if the owner has hired a contractor or contnactora, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
oontraotor, that may be an indication that he |s notproporly]|cenead and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES,: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply tothe construction of new bui|dings, change of
use in existing bui|dinga, or expansion of existing buildings, as specified in paoon County Ordinance number 89-07 and
90-07' as amended. The undersigned also undarotande, that such feao, as may be due, will be identified at the time of
permitting. It is further understood that Transportation |nnpmut Fees'and Resource Recovery Fees must be paid prior to
receiving a ^cerUf|ooha of occupancy" or final power release. If the project does not involve a msrUfioe[e of occupancy or
final power.release, the fees must be paid prior to permit issuance. Furthermore. if Pasco CountyVVater/Sevver Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, os amended): If valuation of work |a $2.50O.00ormore, |
certify that \, the appUoont, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver|tto the"ovvner'prior hocommencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable )av*a regulating construction, zoning and \oOd development. Application is
hereby made to obtain o permit to do work and installation an indicated. | certify that no work or installation has
commenced prior to issuance of e permit and that all work will be performed to meet standards of all |ovva regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. ( also
certify that | understand that the regulations of other government agencies may apply to the intended work, 'nd that it is
nny responsibility toident�/vvha1ooUona | nnuet take boboincompliance. Such agencies include but are not|innibedto:
' Department of Environmental Protection-Cypress Boyhegde, Wetland Areas and Environmentally Sensitive
Lands,VVatenWastevvaterTnaobnent.
' Southwest Florida Water Management District-Wells', Cypress Bayheade, Wetland Areas, Altering
Watercourses. '
' Army Corps ofEDgineero'SeavvaUa' OoOha. Navigable Waterways.
- Dapart0� Rehabilitative of Ha�|�h & �hab|||totive Services/Environmental Health Unit4We||m, Wastewater Treatment,
Septic
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authorih/-Rumwoya.
\ understand that the following restrictions app|yto the use offill:
' Use of fill \a not allowed in Flood Zone"\y' un|esa expressly permitted.
' "if the fill material is to be used in Flood Zone °A". it is understood that a drainage plan addressing a
"compensating vol'u[De'' wiU be submitted at time ofperm\�ingvvhioh is prepared by o professional engineer
licensed by the 8tobaofFlorida.
- If the fill'material is to be used in Flood Zone "/Y' in connection with o permitted building using stem vvo\|
construction, I certify that fill will be used only to'fill the area within the stem wall.
- If fill rnoteda| is to be used in any area, | oorUfv that use of such fill Will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the ovvnaF may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots |ana than one /1\
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,*I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction, | understand that separate permit may be required for electrical work,
p\Urnbing, signs, vve||s' pools, air conditioning, gas, or other iDS1o|\et|ona not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as 'authority to vin|ata, cancel, alter, or
set aside any provisions of the technical codaa, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
uO|eea the work authorized by such permit is commenced within six months of permit ismuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work \scommenced. An extension
may be [aquested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cau'se for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS T8 YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT—
OWNERORAGENT CONTRACTOR
Subscribed and sworn to(or affirrr4gd)beforp mg this Subscribed and sworn to(or affirmed)before me this
Who is/are p or lias/have prodtzed Who is/are personally knov�n to me or has/have produced
as identification. as identification.
Notary Public Notary Public
Commission No. Commission No.
Name of Notary typed,�printed®rt Name of Notary typed,p.rinted or stamped
%, Notary Public State of Florida 1A
.Ley.- Michelle Moyes
067321
My Commission GG 067321
W, _xPIr,6 1 20
���"
AINVOICE (INV-00001636)
FOR CITY OFZEPHYRHILLS
BILLING CONTACT
DAVID GLIDE
D R HORTON INC
12602 TELECOM DR
TAMPA, FL 33637
INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION
INV-00001636 10/19/2020 10/19/2020 Invoiced, Past Due NONE
REFERENCE NUMBER FEE NAME TOTAL
BNR-000752-2020 Address Fee $30.00
Building Permit Fee t 7 l $565.00
Building Plan Review Fee $282.50
Driveway Fee $45.00
Electrical Permit Fee i I 1 $74.00
Electrical Plan Review Feel $37.00
Mechanical Permit Fee $64.00
Mechanical Plan Review Fee $32.00
Park Impact Fee-Single Family/Townhome $769.56
Plumbing Permit Fee 11 '�i $76.00
Plumbing Plan Review Fee `\ _1 $38.00
Public Safety Impact Fee-Admin $26.35
Public Safety Impact Fee-Fire $273.00
Public Safety Impact Fee-Police $254.00
School Impact Fee $6,328.00
SIF 1 percent Fee $83.28
Transportation Impact Fee $3,595.68
Transportation Impact Fee-City $36.32
35659 Stella Vast Drive Zephyrhills, FLORIDA 33541 SUB TOTAL $14,609.69
REMITTANCE INFORMATION TOTAL $14,609.69
City of Zephyrhills
5335 8th Street
Zephyrhills, FL 33542
October 20,2020 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1
n t INSTR#2020159898 OR BK 1018.4 PG 21 17 Page 1 of 1
O9/25/2020 11'.43 AM Ropt:2208353 Rec:10.00 DS:0.00 IT:0:00
' Nikki,,Aivaiez-Sowles,Esq.,Pasco County,Clerk&Comptroller ,
Permit No. Parcel ID No ?.-L 2.
NOTICE 00 COMMENCEMENT
state of __ Florlde County-
of Aasro
THE UNDERSIGNED hereby gives notice that improvement will be made to:certain real property,and in accordance with Chapter.713,Florida Statutes,
the followrn Information is provided In this Notice of Commencement:'
g
1. :. Description of Property: Parcel Identification No. I c4-04 %i t , LS
StreetAddres3: � 1��Vr
y'
2. General Description of Improvement New Sin le FEYY1%LRe idence
3. owner Irftrrriation or Lessee information if the Lessee contracted for the Improvement
D.R. Horton, Inc
Name
'98n2Talarom AVP Tampa 3363Z i=1
Address j City State
Interestin_Property: Fee abilple
Name of Fee Simple Titleholder.
if differentfrom Owner listed above)
Address City State
4.1 Contractor Orton Ja,{3;1� , itloNae
,..
128Q2Tel oom Dries Tam pa ,837
Address City p State
Contractor's Telephone No.:
S. Surety:. W/A
Name" .
Address City State
Amount of Bond: , NIA Telephone No.:
s: -Lender. . NIA
Name.
Address City State
Lender.a Telephone:No ,
7. Persons within the State ff Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(s)(7),Florida Statutes:
David'Gude
Name -
12602 Telecom Drive Terries 33637. FL
Address Ctty State
Telephone Number of Designated,Person: 81&7.40`9720
8. In addtUatito Nmaelt,it ei owner designates . N/A of
to receive a copy offhe Llenufs Notice as provided in Section 71343(t)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner,
9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final,payment Wthe
contractor,butwili be one yearfrom•the date of recording unless a different date is specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE WIRA'nON OF:THE NOTICE OF COMMENCEMENT
ARE CONSIDERED.IMPROPER PAYMENTS UNDER: CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES.-AND CAN
RESULT,IN YOUR.PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST-BE'
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury,I declare that I have read the foregoing once t`commencement and that the facts stated the
rein are true to the best
of my knowledge and belief,
STATE OF FLORIDA Vk
COUNTY OF PASCO
SIg re of Owner or Lessee,or Owners or Lessee's Authorized
Officer/Dimetor/Pertner/Manager'.
A Gtar1 9 retai�r/D R -Hot'tort I e
Sl9nattorr�y.`�s,-Me/Office- ,-�~ N
.The foregoing Instrument was acknowledgsd before me this�day-��� 20&1 by l C���
as�SIStarut SP.�ra�r j (type of authority,e.g.;ot3loer,.trustee,attorney in fact)for
OR Horton, Inc (name of party,on be elf hom Inst mentwas executed).
Personally Known 1A,OR Produced Identification E3 Notary Signature --
Type of Identification Produced Name(Print
��°� Noth y Public Stata of Florida
e 4 Michelle Moyes
mfs`�4 Expmy lrres 1?1211220 ommission GG 327
wpdatalbcslnat eecommenceme LpcOS3048
PLOT PLAN
DESCRIPTION:(AS FURNISHED)
LOT 14, BLOCK 18, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A AND 11B
AS RECORDED IN PLAT BOOK 77, PAGE(S) 79-86, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
TRACT A
DRAINAGE AREA LOT 11
(PRIVATE) BLOCK 18
N89'59'20"W 49.81' iz
yayry L
LOT 14 j ' ?'— GRAPHIC SCALE
BLOCK 18 I 15 30
•(�'� 5,741 SQ.FT f sA
DRAINAGE TYPE B O
L6 LOT 12
s.e'I A/0 „., la6' BLOCK 18
1 28.Y o�COVFRED I
ON LOT CALCULATIONS I c` LANAI. 1
LOT - 5.741 SO. FT. 12.0' ^
LIVING AREA = 1.672 SO. FT. ,+p'
GARAGE 432 SQ. FT. 39.87'
ENTRY 38 SO. FT.
LANAI = 96 So. FT. LOT 1501
PATIO = 0 SO. FT. BLOCK 18 I 1 PROPOSED 11n
DRIVEWAY = 374 SO. FT. LLJ I n " ARIA 1`I LIJ
A/C PAD = 12 SO. FT. O FINISHED FLOOR ~ CO
WALKWAY = 28 SO. FT. I ELEVATION-137.40' 1
IMPERVIOUS o 6 2 SO. FT. O I I (sJ
SOD = 3% So. FT.
p
OFF LOT CALCULATIONS O I 421.3!
OVERED 43. LOT 13
RIGHT OF WAY = 901 SO. FT. O IVY c 0 1 C) BLOCK 18
DRIVE APRON = 217 SO. FT. Z I I
PUBLIC S/W = 313 S0. FT. 5.7'ISOD 371 SO. FT.TOTALS .O�;c c 1 II
AREA = 6,642 SO. FT.
DRIv�_' a
DRIVEWAY = 591 So. FT. -------�� -b"3--'4-:�^;•, `c� i�—
SIDEWALK = 341 SO. FT. 1 '; '•;`::: I
10'LIE
SOD = 3,460 SO. FT. I
1 N 89'59 20 W.=t 50.04
g g�'; •''_�`' ROPOSED INLET
Q H.: NOT FIELD LOCATED
g
z
PREPARED FOR: i CENTERLINE O
_ F
PI _ 511.44' I_33.58' PI RIGHT OF WAY
D•j'(jO Aim Y ( 58951'BEA ) 545.00' — —
�ll■ 11� REFERENCE BEARING
STELLA VAST DRIVE
BUILDING SETBACKS TRACT G
60' WIDE PRIVATE RIGHT OF WAY
FRONT: 22'
REAR: 13'
SIDE: 5' (50' LOTS)
7.5' (55' & 60' WIDTH LOTS)
SIDE STREET: 15'
NOTES:
1. ELEVATIONS SHOWN ARE PER LOT GRADING LEGEND:
PLANS PROVIDED BY THE CLIENT.
2. ELEVATIONS ARE BASED ON NAVD 1988 — BUILDING SETBACK LINE PI POINT OF INTERSECTION
DATUM. _-_ PC POINT OF CURVATURE
3. FOR ALL LOTS WHERE SIDE—YARD CENTERUNE PT POINT OF TANGENCY
SETBACKS ARE LESS THAN 7.50 FEET, A ———— RIGHT OF WAY LINE RP RADIUS POINT
PRC POINT OF REVERSE CURVATURE
MINIMUM 5.00 FOOT WIDE DRAINAGE AND PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE
ACCESS EASEMENT IS REQUIRED PER PASCO PROPOSED DRAINAGE FLOW (5 CONCRETE SLAB
COUNTY LAND DEVELOPMENT CODE.
CONCRETE (P) PER PLAT
CALCULATED
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES A/c AIR CONDITIONERPB) PLAT Boat
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PGS PAGES
THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND SIN SDEWALK SO.FT. SQUARE FEET
OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK F•E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
MAP
LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.I.R.M.
NORTH AMERIICCANN VCE ERTICAL DATUM
AND IS FOR INFORMATIONAL PURPOSES ONLY. NGVD NATIONAL GEODETIC VERTICAL DATUM
D&UE DRAINAGE&UTILITY EASEMENT
THIS IS NOT A SURVEY POE PRIVATE DRAINAGE EASEMENT
PUE PUBLIC U1IU1Y EASEMENT
THIS IS A PLOT PLAN ONLY D&AE DRAINAGE&ACCESS EASEMENT
FLOOD NOTE: SURVEYOR NOTES:
I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE
DATED SEPTEMBER 28. 2014.AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT
APPEARS TO UE IN ZONE-X', AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH
0.27E ANNUAL CHANCE FLOODPLAIN.THE SURVEYOR MAKES No MAY AFFECT THE TITLE OR USE OF THE LAND.
GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE
LOCAL F.E.M.A.AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
BEARING BASIS:
LOCATED EXCEPT AS SHOWN.
BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF STELLA A!5hA 3. NOT VAUD WITHOUT THE AUTHENTIC
VAST DRIVE BEING NB959'20'W,PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC
A M E R I CA N ELECTRONIC SEAL OF A FLORIDA LICENSED
(FIELD DATE:) REVISED: SURVEYOR AND MAPPER.
SCALE: Y'm 30 FEET S U RV E Y 1 N G Digitally signed by James W Boleman
DN:H �' •G�� ,=US, Fl ori da
—AME11CA YING&MAPP
ING,
APPROVED BY: XMAPPING INC_ INCm=JamWBole %
CERTIFICATION OF AUTHORIZATION NUMBER LB/6393 =\, �" •a email=jboleman@asmmrpomtecom
3191 MAGUIRE BOULEVARD, SUITE 200 ry�•.'••''° Date:2070.0878143753-04'00' FOR
JOB NO. 180820 LOT 14, BLOCK 18 ORLANDO, FLORIDA 32803 &'"'°''•s AdobeAmbat—le.11.0.23 R l
DRAWN BY. RMB WWW,AMERICANSUR
PLOT PLAN 28 2020 JC
VEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM 6485 DATE
08
' PASCO COUNTY, FLORIDA
Permit No. .�-
Date Permitted
Builder Name/Owner:Name , Control#'
r
County Parcel No. 7 2_5 Z1 b/f)t9 a4 30[)f�014, SubDiv: 43 U D
Address/Location (/
r �
Classification/Type of Use
TRANSPORTATION IMPACT FEE Rate: SQ.Ft Unit: Z j 23
Exempt n Yes -No How Determined
Impact Fee Amount j. $. �`l��,t30 Zone No. TAM
SCHOOL IMPACT FEE
Account (056) Single-Famlly Detached House Amount $ ,y /f
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [ Yes []No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $
Exempt ❑Yes No How Determined
4 LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑Yes ❑No How Determined Total Amount
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By �' Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED..OR FINAI:INSPECTION
PERFOR
MED UNTIL THE TO t'AL.AMOUNTS LISTED HAVE
BEEN.PAIDUD
RECEIPTED,FOR BY A CENTRAL PERMITTING OFFICE:OF PASCO COUNTY
Acknowledgement below does not imply acceptance of concurrence,but simply recelpt of-a copy.uf.thls form,placing'
the building permit owner on noticg of flits assessment and the'c ondlilons of payment for seine.
DATE RECEIVED BY
RECEIPT NO. DATE BY
Q'
Single Family Dwelling
Plan Review Comments
I. V.X.E.shall.:be a minimum of 8"above the road elevation and an engineered'site plan.
2: .Lots shall"be aded to comp 1Y with"R
. .
"
�' p . .
'401:3 of the F:B.C."
3: . Compaction est required if 24",or more,of fill:dirt is brought in at any one.place.
. . .
4: Tie in survey required before pouring concrete.
5; Driveways require"a R.O X use permit: "All 4 sides-of driveway thru the sidewalk shall have " .
ekpansion material.
6 .All setbacks shall be meet.
7: All.property markers shall'be uncovered.and marked at'time:of first inspection..
8.: All A:D:.A. requirements shall:be:met:
9; No electric plumbing,mechanical;or,framing shall.be covered without an inspection and .
approval'first.
10. All Garages shall comply with section R302:6 of the F.B.C. (Fire"Separation)
11. Appliances.shall.not'be installed in a"location where subject to.mechanical damage unless
protected by:apped M303;4 o the FBC
12. Water heaters shall comply with section P607.3 of the F:B:C:
" -13. Foundation supports for'A/C'units shall.b:e raised at least3" above'fnished grade. M1308:1. .
14:Return air in all bedrooms: F.B:C. M1620:4
15. Smoke detectors.ar6 to be installed mi accordance with R313:1 of the F.B.C.
16:All glazing requirements are to'be in.accordance-with R308.4.of the F.B.G.
17-All means.of egress are to_be in accordance-with R311 of the F.B.C.. .
18. "Green gypsum.-board" shall not be used as a backer in showers or tubs.'R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required-at all.locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be re uired in new construction thatuses fossil-burning heating.
q
or appliances or an"attached garage. They shall be installed-in accordance with the F.B.C:
2:1..All plumbing,mechanical;-and electrical:shall b.e separate from unit.to unit: This includes all
underground plumbing and electric.
22. All 2016"N:E.C. Codes will be enforced:
23. Tamper=Resistant.Receptacles in accordance with 406.11 ofthe:2016 N.E:C
24. In accordance with the.Land Development Code,lots shall.be sodded before final at least 10_
feet around the structure.
25.-.R403.5.3Hot water.pipe insulation.
r InsulatioFi fo hot.water pipe with'a minimum thermal resistance.(R-value)of;R-3 shall.tie applied-to the-
following:
Piping:4.inch (1.9.1.mm)and larger.in.nominal diameter:
Piping_serving more-than:one dwelling unit.
Piping located outside the conditioned space:
Piping from the Water heater to a'distribution manifold.. .
Piping.located under,a floor slab:
Buried in piping,
Supply and return piping in recirculation'systems other than demand recirculation systems:
25.Blower:door test shall'lbe provided Before C.O:
26.A copy of the energy cacls shafl be:with permit at all times
27 COnV of Mal insulation report shall be provided with Dermifbefore final
28. No fenee,-pool or screen enclosure :is issued ivith:this-permit.
F.F.E:-Finished Floor Elevation .
F.B.C-Florida Building,Code 6t'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act: N.E.C.-National Electric.Code(2016)
L Y
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Aria 1672 Elev D 1 Builder Name: DRH Express Homes
Street:j��pS� S t� t `#-!bT �`I Permit Office: (:4
City,State,Zip: Zephyrhills,FL, 33$�+ Q Permit Number: 7CS_Zv / 7
Owner: ` I]J Jurisdiction: 6 (�
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1372.20 ft2
b.Frame-Wood,Adjacent R=11.0 286.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1672.00 ft2
6. Conditioned floor area above grade(ft2) 1672 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(182.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 334
a. U-Factor: Dbl,U=0.34 142.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 4.929 ft.
Area Weighted Average SHGC: 0.317 14.Hot water systems
B. Floor Types (1672.0 sqft.) Insulation Area a.Electric Cap:50 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.109 Total Proposed Modified Loads: 55.99 PASS
Total Baseline Loads: 57.09
I hereby certify that the plans and specifications covered by Review of the plans and 0Z13$
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code. nrn '�•;- = '„
PREPARED BY: - Lmc J,M:• Before construction is completed `
DATE: 1-11- a this buildingwill be inspected for
p c7 ��
compliance with Section 553.908 ii
I hereby certify that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Code. WME
OWNER/AGENT: BUILDING OFF
DATE: DATE:
- Compliance requires certification by the air handler unit'manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
8/19/2020 4:02 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4
FORM R405-2017
FLORIDA ENERGY EFFICIENCY,CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Aria 1672 Elev D Builder Name: DRH Express Homes
Street: �(rj C9 Stto$C� 171'Y Permit Office:
City,State,Zip: Zephyrhills,FL,73 7S�( I Permit Number:
Owner: ` 1� ']J Jurisdiction:
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1372.20 ft2
b.Frame-Wood,Adjacent R=11.0 286.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1672.00 ft2
6. Conditioned floor area above grade(ft2) 1672 b.N/A R= ft2 .
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(182.0 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 334
a. U-Factor: Dbl,U=0.34 142.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 4.929 ft.
Area Weighted Average SHGC: 0.317 14.Hot water systems
8. Floor Types (1672.0 sgft.) Insulation Area a.Electric Cap:50 gallonsEF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 55.99 ��
Glass/Floor Area: 0.109 A
Total Baseline Loads: 57.09
I hereby certify that the plans and specifications covered by Review of the plans and 'fg
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance r,3� rir, ' '` .•°
with the Florida Energy Code.
PREPARED BY: &I& Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code. b W1;`��
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
8/19/2020 4:02 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Aria 1672 Elev D Bedrooms: 3 Address Type: Lot Information
Building Type: User Conditioned Area: 1672 Lot# 14/18
Owner Name: Total Stories: 1 Block/Subdivision: Silverado
#of Units: 1 Worst Case: No PlatBook: Phase 11 B
Builder Name: DRH Express Homes Rotate Angle: 180 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: Garage L Face S
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blocks 1672 14496.2
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1672 14496.2 Yes 4 3 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 192.68 ft 0 1672 ft2 ---- 0.5 0 0.5
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1870 ft2 0 ft2 Dark Y 0.92 No 0.9 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area FIBS. IRCC
1 Full attic Vented 300 1672 ft2 Y N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1672 ft2 0.11 Wood
8/19/2020 4:02 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 4
2
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
nrnt TO Wall Type
1 N=>S Exterior Concrete Block-Int Insul Main 4.0999 18 0 8 8 156.0 ft2 0 0.6 0
2 E=>W Exterior Concrete Block-Int Insul Main 4.0999 44 0 8 8 381.3 ft2 0 0.6 0
3 S=>N Exterior Concrete Block-Int Insul Main 4.0999 38 8 8 8 335.1 ft2 0 0.6 0
4 W=>E Exterior Concrete Block-Int Insul Main 4.0999 57 8 8 8 499.8 ft2 0 0.6 0
5 N=>S Garage Frame-Wood Main 11 20 0 8 8 173.3 ft2 0.23 0.01 0
6 E=>W Garage Frame-Wood Main 11 13 0 8 8 112.7 ft2 0.23 0.01 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>S Insulated Main None .4 3 6 8 20 ft2
2 N=>S Wood Main None .46 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 180 degrees).
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>S 1 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 2 ft 4 in 0 ft 1 in None Exterior 5
2 N=>S 1 Vinyl Low-E Double Yes 0.34 0.31 N 2.5 ft2 7 ft 8 in 0 ft 2 in None Exterior 5
3 S=>N 3 Vinyl Low-E Double Yes 0.34 0.31 N 62.0 ft2 1 ft 0 in 0 ft 9 in None Exterior 5
4 S=>N 3 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 8 ft 0 in oft 1 in None Exterior 5
5 W=>E 4 Metal Low-E Double Yes 0.55 0.34 N 40.0 ft2 12 ft 0 in 0 ft 8 in •None Exterior 5
6 W=>E 4 Vinyl Low-E Double Yes 0.34 0.31 N 15.5 ft2 1 ft 0 in 0 ft 9 in None Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 432.177 ft2 432.177 ft2 49 ft 8.67 ft 0
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000386 1691.2 92.85 174.61 .1459 7
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Heat Pump/ None Sing[ HSPF:8.2 28.6 kBtu/hr 1 sys#1
8/19/2020 4:02 PM EnergyGauge@ USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 4
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ None Sing] SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1
HOT'WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0195 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 334 ft2 Main 40 ft2 Default Leakage Main (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolingr l Jan r�]I Feb �r]l Mar ( �Apr r ]May, rX�Jun Jul Se r Oct N Nov Dec
Heatin [X]Jan LxJ Feb tXJ Mar []Apr ]May' j ]Jun Jul 11"Aug
A4 Sep []Oct Nov X Dec
Ventin [[[ ]]]Jan [[[ ]]]Feb [[[XXX]]]Mar [X]A r ]Ma [[[ ]Jun L Jul Aug l Se ��`XXX��,Oct Nov J Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main
8/19/2020 4:02 PM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 4
r
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
i
The lower the Energy Performance Index, the more efficient the home.
1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location Main
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 3 13.Cooling system: Capacity 28.6
a)Split system SEER
5. Is this a worst case?(yes/no) 5. No b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 1672 d) Room unit/PTAC EER
e)Other 14.0
7.Windows,type and area
a) U-factor:(weighted average) 7a. 0.386
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.317 14. Heating system: Capacity 28.6
c)Area 7c. 182.0 a)Split system heat pump HSPF
b)Single package heat pump HSPF
8.Skylights c) Electric resistance COP
a) U-factor:(weighted average) 8a. NA d)Gas furnace,natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other 8.20
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood,raised(R-value) 9b. 15.Water heating system
c)Concrete, raised(R-value) 9c. a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10131. 111.0
2. Masonry(Insulation R-value) 10132.
16.HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a) Ceiling fans
a) Under attic 11 a. .30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c)Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. :Yes e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT.
certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded) in�this home before final inspection. Otherwise,a new EPL
display card will be completed based on installed code"compliant features.
Builder Signature: ` ----- Date: 1Tl�
Address of New Home:_`zq-(o" -S,tc(IQ_ City/FL Zip: Zephyrhills. FL 3 J�
8/19/2020 4:02:53 PM EnergyGauge®USA 6.0.04(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: Permit Number:
F
Zephyrhills,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
(Section 553.9085, Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately of
the plans
and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal enveloW building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(1)or
an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures.
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures.
3.Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where
using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the
fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
Fi R402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
8/19/2020 4:03 PM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software , Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
❑R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to
open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential.
❑R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or
(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(1), Florida Statutes,to be"substantially leak free"in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow,rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1, Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the
manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the
entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 1050F(41°C)
or below 55°F(131C)shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that
caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return
❑ pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
8/19/2020 4:03 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's
expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF(4.8°C).
❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered
energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required.
R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
8/19/2020 4:03 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies(Mandatory).
R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 100°F to 140OF(38°C to 600C).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of
combustion types of service water-heating systems to be turned off.
R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar
water-heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation
including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air Quality,shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3• If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10
otherwise.
R403.7 Heating and cooling equipment(Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that
affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU
(CFM) (CFM/WATT) (CFM)
Range hoods Any 2.8 cfm/watt Any
In-line fan Any 2.8 cfm/watt Any
Bathroom,utility room 10 1.4 cfm/watt <90
Bathroom,utility room 90 2.8 cfm/watt Any
For SI:1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916
8/19/2020 4:03 PM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas(Mandatorg0he energy consumption of electric-powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps.
Exception:Low-voltage lighting.
R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights.
8/19/2020 4:03 PM EnergyGauge@ USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5
2017- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Aria 1672 Elev D Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhills, FL, Permit Number: Y
U
Owner: Jurisdiction: W
Design Location: FL,Tampa U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attics aces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac 3s.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the drywall.. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers.and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub-floor or drywall.
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
-over Plates and walls or a.In addition,inspection of log walls shall be in accordance with the provisions of ICC 400.
8/19/2020 4:03 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: Permit#:
Jab I'Informatiori -
Builder: DRH Express Homes Community: Lot: 14/18
Address:
City: Zephyrhills State: FL Zip:
Air'L0aka-e Test;Result',': :Passin';,results:m'ust,meetEeither-the;Pedbfih nee;;Pcescri"five;.or i Mettiad,
9 .f 9 . P ..
Q, "PRESCRIPTIVE"METHOQ�Th&building,gr dwelling.uhiishall!be felted and verifiedias havingiah air"leakage rate of rioi ezceed'ing,7 ai'
- .
dhahges r•hdur at a ;ressure df:D:2,inch w bO P`ascal6;in Oiimate•Zones t aria 2:-
Pe p g:::(. )
PERFORMANCE=o�ERI"METHO�=The fiuildin 'or dwellin urift shall,be tested`and+'verified as fiavin' san'air leakae,rate:ofriot,exceedi
tfieiselectedACH(50)value;,as shown;oh.Form A405=2Q17(Rerformahce)`or R406 20t7{ERI).sectioha t%led.as:inffltratiorisut5=sectionA6H50.1
A'CH(56),spoilredon=Form,R405=20:17=Erfergy,,Calc:(Peiformai? ):or,R40B201;7(EA1J 7.000
x 60 = -7.791602E26 — Method for calculating building volume:
CFM(50) Building Volume ACH(50)
O Retrieved from architectural plans
F—] PASS 10 Code software calculated
When ACH(50) is less than 3,Mechanical Ventilation installation Q Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration
control measures.
2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control
measures.
3.Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
- - _
Testing:Gornpa-y 77
-
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification#: Issuing Authority:
8/19/2020 4:03:20 PM EnergyGauge®USA 6.0.04(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
+ .wrightsoft, Manual S Compliance Report Date:
Entire House ey:
Progressive Air Systems, Inc Plan: Aria 1672
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
Rroject Information
For: DR Horton
Lot 14 Blk 18 Silverado, Zephyrhills, FL
-Cooling EqjApment
Design Conditions
Outdoor design DB: 91.2°F Sensible gain: 20927 Btuh Entering coil DB: 77.2°F
Outdoor design WB: 77.1 OF Latent gain: 3639 Btuh Entering coil WB: 63.6°F
Indoor design DB: 75.0°F Total gain: 24566 Btuh
Indoor RH: 50% Estimated airflow: 1000 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIItASHP
Manufacturer: Carrier Model: CH14NB030+FB4CNP030
Actual airflow: 1000 cfm
Sensible capacity: 23631 Btuh 113%of load
Latent capacity: 3687 Btuh 101%of load
Total capacity: 27319 Btuh 111%of load SHR: 87%
Waiting Equipment
Design Conditions
Outdoor design DB: 40.0°F Heat loss: 21693 Btuh Entering coil DB: 69.2°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer: Carrier Model: CH14NB030+FB4CNP030
Actual airflow: 1000 cfm
Output capacity: 25624 Btuh 118%of load Capacity balance: 32 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1000 cfm
Output capacity: 6.4 kW 101%of load Temp. rise: 20 OF
Meets are all requirements of ACCA Manual S.
wri htsoft° 2020-Aug-1916:03:37
9 Right-Suite@ Universal 2017 17.0.21 RSU25554...soft Flles\DR Horton\Express\Aria 4EAB 1672.rup Calc=MJ8 House Front faces: S Page 1
- - wrightsoft° Load Short Form Da
Job:
House By:
Progressive Air Systems, Inc Plan: Aria 1672
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
Project • •
For: DR Horton
Lot 14 Blk 18 Silverado, Zephyrhills, FL
Design Information
Htg Clg Infiltration
Outside db(°F) 40 91 Method Simplified
Inside db(°F) 70 75 Construction quality Semi-tight
Design TD (OF) 30 16 Fireplaces 0
Daily range - L
Inside humidity (%) 50 50
Moisture difference(gr/lb) 26 54
HEATING EQUIPMENT COOLING EQUIPMENT
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model CH14NBO30 Cond CH14NBO30
AHRI ref Coil FB4CNP030
AHRI ref
Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 22500 Btuh
Heating output 29600 Btuh Co) 47OF Latent cooling 7500 Btuh
Temperature rise 27 OF Total cooling 30000 Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.046 cfm/Btuh Air flow factor 0.048 cfm/Btuh
Static pressure 0.48 in H2O Static pressure 0.48 in H2O
Space thermostat Load sensible heat ratio 0.85
Capacity balance point=32 OF
Backup:
In ut=6 kW Out ut=21934 Btuh 100 AFUE
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
m bed 237 3521 2709 162 129
dining 183 3260 3677 150 176
great 275 3513 3405 162 163
wic 49 938 461 43 22
we 25 0 0 0 0
m bath 135 1895 1077 87 51.
kitchen 146 187 2066 9 99
laundry 42 266 960 12 46
bed 3 154 1705 1984 79 95
foyer 125 1746 1610 81 77
bath 2 60 706 389 33 19
bed 2 166 3954 2590 182 124
a/c 14 0 0 0 0
hall 37 0 0 0 0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
1 WI'1 F1t50fit" 2020-Aug-1916:03:37
Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1
AWN ..soft Files\DR Horton\Express\Aria 4EAB 1672.rup Cale=MJ8 House Front faces: S
Entire House d 1647 21693 20927 1000 1000
Other equip loads 0 0
Equip. CP 1.00 RSM 20927
Latent cooling 3639
TOTALS 1647 21693 24566 1000 1000
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Aug-19 16:03:37
wrightsoft' Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2
...soft FIJes\DR Horton\Express\Arla 4EAB 1672.rup Gaic=MJ8 House Front faces: S
AHRICERTIIFIEW
www.ahr I dire ctory.or g
ARC MOI&N
ific f Product Ratings
AHRI Certified Reference Number:9162305 Date:02-19-2019 Model Status Active
AHRI Type:HRCU-A-CB
Series:14 SEER HP
Outdoor Unit Brand Name:CARRIER
Outdoor Unit Model Number (Condenser or Single Package):CH1 4NB030*0**A*
Indoor Unit Model Number(Evaporator and/or Air Handier):FB4CNP030L
The manufacturer of this CARRIER product is responsible for the rating of this system combination.
Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda I and 2,Performance Rating of Unitary
Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing:
Cooling Capacity(A2)-Single or High Stage(95F),btuh:28600
SEER:14.00
EER(A2)-Single or High Stage(95F):11.60
Heating Capacity(H12)-Single or High Stage(47F) 28600
HSPF(Region IV):8.20
t"Active"Model Status are those that an AHRI Certification Program Participant Is currently producing AND selling or offering for sale;OR new models that are being
marketed but are not yet being produced:Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still
selling
— 0==Vled by WAS indicate an involuntary r - e
Rafigg',
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations-listed in the
directory at wwwahrldirectory.org.
TERMS AND CONDITIONS
This Certificate and Its contents ate proprietary products of AHRI.This Certificate shall only be used for Individual,personal and
confidential reference purposes.The contents of this Certificate may not,In whole or In part,be reproduced;copied;disseminated;
entered into a computer database-,or otherwise utilized,in any form or manner or by any means,except for the user's individual,
personal and confidential reference. AIR-CONDITIONING,HEATING,
CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE
The Information for the model cited on this certificate can be verified at www.ahrldirertory.org,click on"Verify Certificate"link we make life bettei-
and enter the AHRI Certified Reference Number and the date on which the certificate was Issued,
which is listed above,and the Certificate No.,which is listed at bottom right) 1
02019Air-Condlitioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 13950823461116629
FORM R405-2017
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance)Method
Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the
residential Simulated Performance Method shall include:
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(one page)and an input summary checklist that can
be used for field verification(usually four pages/may be greater).
❑ Energy Performance Level(EPL)Display Card(one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Requirements(five pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - '
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage; then a completed
Form R405 Duct Leakage Test Report(usually one page)
8/19/2020 4:02:30 PM EnergyGauge®USA 6.0.04(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1