Loading...
HomeMy WebLinkAbout20-764 P i Q Min , City p Y of Ze h rhilis ,i PE,12MI,Tx,NUMBER 5335 Eighth Street r, w Zephyrhills, FL 33542 BNR-000764-2020 t, Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 10/29/2020 Permit Type: Building New (Residential) sProperty mbe M Aii om .r 32 25 21 0040 01300 0030 7036 Steer Blade Drive ' 'Own"er information,� Permit Info inatiori ° "# "A "C,ontr cto,Information ; Name: D R HORTON Permit Type:Building New(Residential) Contractor: D R HORTON INC Class of Work:SFR Construct Address: 12602 Telecom Dr Building Valuation:$130,000.00 TAMPA,FL 33637 Electrical Valuation:$7,000.00 ` Phone: (813)549-1968 Mechanical Valuation:$4,500.00 Plumbing Valuation:$7,200.00 ^ `' Total Valuation:$148,700.00 '/,(J Total Fees:$14,781.44 vvv Amount Paid:$14,781.44 Date Paid:10/29/2020 2:30:20PM Pro *ect�Desq ri tr,on�= <�:; -�� ``x• , � : ��"� ;��, ,r:•.� �'M CONSTRUCT SINGLE FAMILY 2,755 SQ FT SILVERADO _fir.. '$rx ai- - Application�Fees Public Safety Impact Fee-Admin $26.35 School Impact Fee $8,328.00 Transportation Impact Fee-City $36.32 Electrical Plan Review Fee $37.50 Building Permit Fee $680.00 Electrical Permit Fee $75.00 Park Impact Fee-Single Family/Townhome $769.56 Mechanical Permit Fee $62.50 Address Fee $30.00 Public Safety Impact Fee-Police $254.00 Transportation Impact Fee $3,595.68 Plumbing Plan Review Fee $38.00 Building Plan Review Fee $340.00 Mechanical Plan Review Fee $31.25 Plumbing Permit Fee $76.00 Public Safety Impact Fee-Fire $273.00 Driveway Fee $45.00 SIF 1 percent Fee $83.28 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER I I w-w—v City of Zephyrhills Permit Application Fax-813-780-0021 Building Department D 1�ck�SI,2 emuc� At 0 C)iekOrtOD, com ate Received Phone Contact for Permitting Owner's Name J QL Owner Phone Number Um er Owner's Addressl 2 T a- 3�L Owner Phone Number -Fee Simple Titleholder Name -sn w_, Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS F mo ishar- -btm 249P6-fk/L��, FOS", LOT# /),3 PARCEL ID# 3Z- 2-1;7 7-1 W4o 01360 06,30 SUBDIVISION F3 I i�, (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR R ADD/ALT SIGN DEMOLISH E5 INSTALL REPAIR PROPOSED USE = , SFR = COMM OTHER TYPE OF CONSTRUCTION rz", BLOCK Q FRAME STEEL F7 DESCRIPTION OF WORK =W ,) '�ilmlo (�Wdq rt?45N A F n(_L QJ10 BUILDING SIZE SQ FOOTAGE Za HEIGHT =BUILDING VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS ROOFING Q SPECIALTY u OTHER FINISHED FLOOR ELEVATIONS F E7 ' FLOOD ZONE AREA =YES NO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - - - - - - - - - - BUILDER COMPANY IV\C SIGNATURE REGISTERED FEtCURREN Y/N Address 02_ K —7a MID& License# ELECTRICIAN COMPANY SIGNATURE FEE CORREN Address &JO "5.4rd ­,27-4-11 License# -2, Q 033-13- I "IlA hkftln f/ Mbr4 6 PLUMBER . COMPANY 1/ ;,1 SIGNATURE REGISTERED Y/ N 'FEE CURR�dt, Yl N I Address n vr- TZ C f-C 691 ;�z i 4mpa --S3617- License# MECHANICAL COMPANY SIGNATURE REGISTERED FEE CURREN _t��/N 0_/3. Address S 0 i 0 t�JP W 114A 34�S__]I License# 1 cpr cc 33 OTHER COMPANY ra J C. SIGNATURE REGISTERED Y/ N I FEE CURkEI\ 'L_y LN_JJ Address Nlaf,666W3 License# 1 ar :IS 2,5-_2 3 3 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumoster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone With notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive.than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may.be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as.required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing.Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly.licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees•and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power•release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. ' - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill•material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill :will not adversely .affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDAJURAT-(F.S:11-7-.03) - - - -- - OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affir d)befor me this Subscribed and sworn to(or affirmed)before me this by�Sl P f rLA by Who is/are personally known to me or has/have procItrued Who is/are personally known to me or has/have produced as identification. as identification. Notary Public Y Notary Public Commission No. Commission No. Name of Notary typed,printed or st Name of Notary typed,printed or stamped ,c► puo` Notary Public State of Florida 4".2 Michelle Moyes My Commission GG 057321 4 Expirea 11212112020 INVOICE (INV-00001706) FOR CITY OF ZEPHYRHI,LLS BILLING CONTACT DAVID GUDE D R HORTON INC 12602 TELECOM DR TAMPA, FL 33637 NOW INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS::[INVOICE DESCRIPTION INV-00001706 10/26/2020 10/26/2020 Invoiced, Past Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-000764-2020 Address Fee. $30.00 Building Permit Fee 'OV $680.00 Building Plan Review Fee $340.00 Driveway Fee $45.00 Electrical Permit Fee $75.00 Electrical Plan Review Fee $37.50 Mechanical Permit Fee $62.50 Mechanical Plan Review Fee $31.25 Park Impact Fee-Single Family/Townhome $769.56 Plumbing Permit Fee $76.00 Plumbing Plan Review Fee $38.00 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Fire $273.00 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 SIF 1 percent Fee $83.28 Transportation Impact Fee $3,595.'68 Transportation Impact Fee-City $36.32 7036 Steer Blade Drive Zephyrhills,FLORIDA 33541 SUB TOTAL $14,781.44 REMITTANCE INFORMATION TOTAL City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 October 27,2020 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 1 • Single Family Dwelling Plan Review Comments 1. F RE, shall be a ininimum of 8" above the road elevation and an engineered site plan. 2: Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require.a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall bo met. 1: All.property markers shall be uncovered.and marked at time of first inspection. 8: All A.D.A. requirements shall be met. 9; No electric,plumbing,in or framing shall be:covered without an inspection.and approval first. 10: Alt Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances sh I not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the E.B.C. 11 Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1 14. Return air in all bedrooms. F.B.C. M1620.4 1.5. Smoke detectors are to be installed in accordance with R313:1 of the F.B.C. 16. A11 glazing requirements are to be in accordance-with R308.4 of the F.B.C: 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum.board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monokide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. Thoy shall,be installed in accordance with the F.B.C: 21. All plumbing,in6chanical, and electrical shall he separate from unit to unit. This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25. R403.5.3Hot.wate(pipe insulation Insulation for hot,water pipe With a minimum thermal resistance (R-value) of R-3 shall be applied to the following:, Piping 31,inch (19.1 mm)and larger in.nominal diameter. Piping serving more than one dwelling unit.- Piping located outside the conditioned space. Piping from the Water heater to a distribution manifold. Piping located under a floor slab.. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower door test shall be provided before C.O: 26 A copy of the eneroy cacls'shall be with yerinit at all times. 27. CopV of fitnal'insulation report shall be provided with permit before fnal 28. No fence,pool or'screen enclosure .is issued with This permit F.F.E.-Finished Floor Elevation F.B.0 Florida Building Code 60'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) PASCO COUNTY, FLORIDA Permit No. Date Permitted Builder Name/Owner Name �6r-lv), Control County Parcel No. 32 ZS^2•l 06(/fl 013D DO30 SubDIv: Address/Location 7046 5 61a_olP dk Classi8cationfi'ype of Usg TRANSPORTATION IMPACT FEE - Rate: Sq.Ft Unit: Exempt []Yes F1 No How Determined Impact Fee Amount $. _Sz 6 32' Zone No. TAZ: SCHOOL IMPACT FEE Account (656) Single-Family Detached House Amount $ 1� (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [ Yes. No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ , 162,576 I- Exempt ❑Yes Q No How Determined ! LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes 0 No How Determined Total Amoun RESOURCE FEE ERLI TOTAL AMOUNT Prepared By c _� Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED.OR FINAL.INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID:AND RECEIPTED FOR BY A CENTRAL.PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not Imply,acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on noticd of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 6• PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 3, BLOCK 13, SILVERADO RANCH SUBDIVISION PHASE 10A AS RECORDED IN PLAT BOOK 80, PAGE(S) 107-112, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. 401- .Q g0 \ 'Pity FO PRC + GRAPHIC SCALE 0 15 30 T3 �O>1 06,1130.67 Pc ,��� OIL 0. ON LOT CALCULATIONS 1, '� ••`'a \\♦ LOT = 11,213 SO. FT. d m ebb. \ LIVING AREA — 2,045 SQ. Fr. ,>� LOT 3 GARAGE = 454 SQ. FT. m BLOCK 13 .\\\ = ENTRY — 35 SQ. FT. 11,213 SQ. FT f 129.e9 LANAI = 221 SQ• FT. 2 DRAINAGE TYPE AA \ PATIO = 0 SQ. FT. r �J9 L k DRIVEWAY = 378 SQ. FT. 1LCR•,c(�d� A/C PAD = 12 SQ• FT. ti ��. ' 2 �g`���\�3•� �( ` WALKWAY = 45 SO' FT. 0$ o "' IMPERVIOUS = 28% 0- \ $ FY = 3190 SQ. FT. SOD = 8,023 SQ. FT. ��Z" rpo OFF LOT CALCULATIONS / RIGHT OF WAY = 3166 SO. FT. J m^` •. DRIVE APRON = 229 SO. FT. :.::rA ►�. �, PUBLIC S/W = 1000 SO. FT. 2 SOD = 1,937 SO. FT. vO� 1� !S w < .= �s• ,wry TOTALS 14,379 SO. FT. �G� AREA \eS DRIVEWAY = 607 SO. FT. SIDEWALK — 1045 SO. FT. 0� / SOD = 9,960 SO. FT. -k Curve Table \ / PREPARED FOR: Cur"IIILength Radius Delta Chord Bearing Chord .V/ �pry�p� ,�;++�1. c1 52.73' MO.00' 9'01117' N6524'12'E 52,67' 130.9 B•R'HORMNtl C2 35.OW 25.00' 8024'14' S7858'20'E 32.27' � ``� ''`�°�'` C3 31.14' 290.00' 6'09'12' S4150'49'E 31.1V BUILDING SETBACKS C4 129.94' 830.00' 1149'03' S64104'19'W 129.7i'l 130.0 FRONT: 22' C5 114.25' 630.00' 1023'25' S6321'30*W I'll 2' Line Table REAR: 13' 1 C8 1 15.69' 830.00' 125'38' I S69'I6-OrW 1 15.69' Una/ Direction Length SIDE: 5' (50' LOTS) L1 53846'13'E 35.62 7.5' (55' & 60' WIDTH LOTS)' SIDE STREET: 15' NOTES: 1. ELEVATIONS SHOWN ARE PER LOT GRADING LEGEND: PLANS PROVIDED BY THE CLIENT. 2. ELEVATIONS ARE BASED ON NAVD 1988 DATUM. — — — BUILDING SETBACK LINE PI POINT OF INTERSECTION 3. FOR ALL LOTS WHERE SIDE—YARD —— — CENTERLINE PC POINT OF CURVATURE PT POINT OF TANGENCY SETBACKS ARE LESS THAN 7.50 FEET, A ———— RIGHT OF WAY LINE RP RADIUS POINT MINIMUM 5.00 FOOT,WADE DRAINAGE AND PRC POINT OF REVERSE CURVATURE ACCESS EASEMENT IS REQUIRED PER PASCO PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE COUNTY LAND DEVELOPMENT CODE. TYP PROPOSED DRAINAGE FLOW CS TYPICAL CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE PER PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (C PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER pe PGS PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SQ. FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY NCVD NATIONAL GEODETIC VERTICAL DATUM D&UE DRAINAGE&UTILITY EASEMENT THIS IS A PLOT PLAN ONLY PDE PRIVATE DRAINAGE EASEMENT PUE - PUBUC UTILITY EASEMENT - - FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F. 1• THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26,2014, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO UE IN ZONE'X',AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION• PLEASE CONTACT THE LOCAL F.E,M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: LOCATED EXCEPT AS SHOWN. BEARINGS SHOWN HEREON ARE BASED ON THE SOUTHWESTERLY LINE 3. NOT VAUD WITHOUT THE AUTHENTIC OF LOT 3,BLOCK 13 BEING N2732'09'W PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) REVISED: M E FR 1 CAN SURVEYOR AND MAPPER. SCALE: 1'w 30 FEET S U RV IE-= I N G s.uew.'DigitallysignedbyJamesWeoleman f;... , DN:c=US.st=Florida,l=Orlando, $c MAPPING INC. ;? � s. 'o=AMEHICAN SUgVEYING& APPROVED BY: 1J� MAPPING,INC,rn.1—W CERTIFICATION OF AUTHORIZATION NUMBER LB18393 —+n. a Mleman, 200647 LOT 3, 3191 MAGUIRE BOULEVARD, SUITE 200 $`••••• e-11=lbdeman@as rpomte.com FOR JOB NO. BLOCK 13 ORLANDO, FLORIDA 32803 " ' Date 2030.0a7375:4P51-09'00 THE FIRM PLOT PLAN 2 OB 11 2020 JG (407) 428-7979 DRAWN BY: °� PLOT PLAN DB 18 2020 JG WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE PASCO COUNTY Receipt Date: 03/25/2021 ��J�A C BUILDING CONSTRUCTION SERVICES Receipt Number. 2030075 1 1 1 F 8731 Citizens Drive COUNTY FLORIDA Suite 230 OPHN Siwxs.t4paw P(ACJ:S. New Port Richey,FL 34W4 727-847-8128 NOT A PERMIT ** Paid By Check CC Auth# Cashier ID Workstation Check 1270757 SLEBLANC BCCCP59L Fee Description Amount Paid Impact Fee Residential Solid Waste Single Family 50.22 Total Payments: $50.22 a o dA dres one DR Horton Comments: City of Zephyrhills Solid Waste Address:7036 Steer Blade Drive Parcel ID:32 25 210040 0130 0030 White you will be paying your bU with Pesm County Building cnnt—tUn Services,the full amount or the aeditoerd a -sheckfeeh NOT shownabove,is cdened by Plot HIIDng payment servkoa. Check Number 1270757 PASCO COUNTY BOARD OF COUNTY COMMISSION Date 03/25/21. 7530 Little Road DRH Inc,Controlled AM Stub 1 of 1 691487 PO Numb Invoice Number Subdv Lot# Lot Address Cost Cde Legai Desc Gross Deductions Amount Paid -------- ______..._____. ---- __________ _____________ ------------- _____________ 392510039IMP 39251 0039 7036 STE"LADE DRIVE 80/108 5D.22 50.22 50.22 50.22 myreportsheports//produodomPASCO/CustomerReceipt vlfrpt Print Date: 03/25/2021 Page 1 of 1