Loading...
HomeMy WebLinkAbout20-774 D City Of Zephyrhills PERMIT NUMBER . 5335 Eighth Street Zephyrhills, FL 33542 BGR-000774-2020 Phone: (813)780=0020 Fax: (813)780-0021 Issue Date:.09/25/2020 Permit Type: Building General (Residential) Property Number Street Address 24 26 21'0090 00000 0320 3245 Moulden Hollow Drive Owner Information Permit Information Contractor Information Name: MARIO RODRIGUEZ Permit Type:Building General(Residential) Contractor:WINDMAR HOME FLORIDA Class of Work:Electric Service Replacement/ INC Address: 3245 Moulden Hollow Dr Building Valuation: ZEPHYRHILLS,FL 33540-7309 Electrical Valuation:$56,386.67 Phone: (813)317-3941 Mechanical Valuation: Plumbing Valuation: Total Valuation:'$56,386.67 �I Total Fees: Amount Paid:d:$482.$482.89 l�(J Date.Paid:9/25/2020 10:22:32AM. ! Project Description INSTALLATION ROOF MOUNT SOLAR SYSTEM r Application Fees Electrical Permit Fee $321.93 Electrical Plan Review Fee $160.96 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever-is greater,for each subsequent reinspection. Notice: In addition to=the requirements of this permit, there may be additional restrictions applicable.to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend;to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. O TRA O SIGNATURE PEJAIT OFFICE " PER MI E PIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8. HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INSTR#20201596/5 OR BK 10184 PG 924 Page 1 of 1 09/25/2020 09:54 AM Rept:2208141 Rec: 10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller 4 r , I , Permit No. (aC ` Parcel ID No 24.26-21-0090-00000-0320 NOTICE OF COMMENCEMENT State of FLORIDA County of PASCO THE UNDERSIGNED hereby gives notes that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Parcel Identification No. HIDDEN RIVER PHASE ONE A PB 74 PG 101 LOT 32 OR 9763 PG 2082 Street Address: 3245 MOULDEN HOLLOW DRIVE,ZEPHYRHILLS,FL 33540 2. General Description of improvement INSTALLATION OF ROOF MOUNTED GRID-TIED PV SYSTEM I y . Owner Information or Lessee Irdon,ailon 9 the Lessee contracted for the lmprovemerlt N MAR)O OSCAR COLLAZO RODRIGUEZ karne E > 3245 MOULDEN HOLLOW DRIVE Z9.PHYRHILLS FL O 3 Address City State N 0 interest in Property. OWNER Ca p, c v N Name of Fee Simple Titleholder. ,e.. •Q O•— rA (if different from Owner listed above) Ca) c Address City State cv p O Convector. WINDMAR HOME FLORIDA,INC. a� +- O Nero 0O O 6753 KINGSPOINTE PARKWAY SUITE 191 ORLAN00 FL a m CCL N Address City State v c> O Contractors Telephone No.: 407-308-0090 fl c O O - a A--00 m N Name } ress City State Am nt of Bond: $ Telephone No.: Lender. Name Address City State Lenders Telephone No.: T. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provded by o Section 713.13(1xa27),Florida Statutes: �yy �k:+,i '� Name N Address City State `pad as oo Telephone Number of Designated Parson: d� mad In addition to himself,the owner designates of to receive a copy of the Lienors Notice as provided in Section 713.13(lXb),Florida Statutes, aP_ Telephone Number of Person or Entity Designated by Owner, 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be am year from the data of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713. PART I. SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEM£NIr MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penally of perjury.I declare that I have read the foregoin comma ent and thal fads stated therein are true to the best of my kwMedge and belief. / STATE OF FLORIDA ' COUNTY OF PASCO o Owner Losses,or e1..or Lessee's Auttloiraed Office'DI tor7PaMeriManeget C DR GERSIPOA Signatory's Title/Off oo The foregoing Instrument was acknowledged before me this 21STday of AUGUST•20 a by CHAD ROG'ERS as PDA (type of authority,e.g.,officer,trustee,attorney in tad)for MARIO OSCAR COLLAZO RODRIGUEZ &%1101.11e on instrument was executed). Personalty Known®98 Produced Identification❑ 1 ryOS Type of Identification Produced , ice Nar*(Print)�� ' 00 KA ..,. +�. My Comm.Expires -' OCT S.2021 No.GG148982 °JBL1G `'. wpdawbcwnodcocorntmncomont—Peo53049 tlr)l ltibl.l"IN 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting qb --t/ a a a a I a I[ W 9 1 9 T I I a a a Owners Name MARIO OSCAR COLLAZO RODRIGUEZ Owner Phone Number 8133173941 Owner's Address 3245 MOUL.EN HOLLOW DRIVE,ZEPHYRHILLS,FL 33540 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 3245 MOULDEN HOLLOW DRIVE,ZEPHYRHILLS,FL 33540 LOT III 32 SUBDIVISION HIDDEN RIVER PARCEL ID# 24-26-21-0090-00000-0320 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED B NEW CONSTR BX ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK INSTALLATION OF ROOF MOUNTED GRID-TIED PV SYSTEM BUILDING SIZE SQ FOOTAGE HEIGHT c�cX c cc BUILDING $ 56,386.67 VALUATION OF TOTAL C TRUCTIONI =ELECTRICAL $ AMP SERVIC = PROGR SS ENERGY C. =PLUMBING $ `�[/ =MECHANICAL $ ALUATION OF MECHANICAL INSTALLATION V =GAS = ROOFING Q OTHER / FINISHED FLOOR ELEVATIONS FLOOD_ZO_NE.AR_EA =YES NO BUILDER � 4u" COMPANY WINDMAR HOME FLORIDA,INC. 9 SIGNATURE - REGISTERED Y 1 N FEE CURREN {Y Address 6753 Kingspointe Parkway Suite 111 Orlando,FL 32819 License# rCVC57118..-- - ELECTRICIAN COMPANY SIGNATURE REGISTERED =1Y/N FEE CURREN Y/N Address I License# PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address I License# OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal data.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required.(A/C upgrades over$7500) Agent(far the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility,for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the'owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPAOVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LE Ll A-rq&INEY BEFORE RECORDING YQUR NOTICE QF CQMMENCEMENT. FLORIDA JURAT(F. .11 OWNER OR AG L. G CONTRACTOR_ Subscribed and omtb,(or ffir ed before th Subscrib sw o(or affirmed)befor me this 8/21/2020 by GE S 8121/2020 by JEREMY BOOSKA Who is/are personally known tom or has/have produced Who is/are personally known to me or has/have produced s identification. as identification. Notary Public Notary Public Commission No. H011 Commissio CARLOS L E CARLOS Name of Notar?QZe4,11rinMd or stamped Name of Notary ty d,printed or s e , _ H 0 LIMITED POWER OF ATTORNEY State of Florida I do hereby authorize, Chad Rogers, of Windmar Home Florida, Inc. to sign and apply for permits on my behalf.This authorization is valid only for the purpose of obtaining a permit to perform the solar installation work contracted for by and between owner and Windmar Home Florida, Inc. The only permit (s) which may be applied for under the terms of this limited power of attorney are those which the authority having jurisdiction deem(s) necessary under the current Florida building code, given the scope of work contracted for. Windmar Home Florida, Inc. will be responsible for any and all fees associated with this permit application.The authorization will remain valid until such permit(s) is/are issued by the respective building department, or until (180) calendar days from the date listed below have transpired,whichever is less. IN WITNESS WHEREgFjhave ex "� is Limited Power of Attorney, SR, ature: Print Name: r Date: Before me, the undersigned authority, duly authorized to take acknowledgements and administer oaths,personally appeared,personally known to me or produced driver's license as identification to be the person described above,who being by me first duly sworn states that(His or Her)is the person who executed the foregoing instrument for the reasons expressed therein, Dated this day of A 20.?,_O, NOTARY PUBLI a0tAp My Coinmission Expir = biy Comm.Expires OCT 5,2021 No.GG148982 %cfj pUgl Qin�i `1 Home Florida,Inc, ointe Parkway Suite 111 �j���r►rni11�� Orlando, FL32819 CONTACT US: 6763 KINGSPOINTE ' _ PAAKWAYSUITE111, ORLANOOFL,32819ASA TEL M 407.308-0099 Lennar A Hidden River k 103245 MD,w en Hallow Drire Loving You.® SkmBHDiI `I 1,'•'� 00cn LOCATION MAP AERIAL VIEW PLAN VIEW J a 0 LL J 2 COORDINATES:LAT 28.204161°,LON-82.163167° COORDINATES:28°12'16.0"N,82°09'47.4"W O Z J t) W O 0 - � it Q 0 = a I v N A WORK SHALL COMPLY WITH PREY i I�1G `14 INDEX PERMITTINGlLANNING NOTES CODES FLORIDA BUILDING CODE, NATIONAL tLECTR C 0 AND THE CITY OF ZEPHYRHILLS C-1 COVER SCOPE OF WORK: ORDINANCES _ E-1 ELECTRICAL DIAGRAM & CALCULATIONS INSTALLATION OF GRID-TIED PHOTOVOLTAIC SYSTEK4.--•' VA' �•F IRE 5 ~ ° S-1 STRUCTURAL DIAGRAMS I No.s6 • � �Ew�AT SEP S-2 STRUCTURAL CALCULATIONS PLAN�E� IlVe, NOTE:ENGINEER CERTIFIES THAT THIS PLAN COMPLIES WITH 107.35 FBC. •••s j'STATE f » - I ••.•aMA REVISIONS IMPORTANT NOTE:NEC 705.12(D)(2)(3)(B) FILL CALCULATIONS NOTE: NUMBER OATS OESCRlPTON W)MERE T UAOB,TNE SOME A VnUTY MID IMIEER ER AN R LOCATED CURREM AN OTMERATIN ENDS THE WSSARREMTHAT --- -- -- DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 12D%THE AMPACITY OF THE BUSBAR THE BUSEAR SHALL BE SUED ALL FILL CALCULATIONS ON THIS DESIGN HAVE BEEN DONE IN COMPLIANCE WITH NEC312A. �DL'I'1 BG FOR THE LOAD$CONNECTED IN ACCORDANCE PATH ARTICLE Vk A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EOVIPMENT ADJACENT TO THE RAGWEED BREAXER FROM ME eNF.RTER THAT DISPLAYS THE FOLLOWING OR 6.25.2020 wnrtx44G: ° _— 91VERTEq OUTPUT coxNEDTION;DO Nar RELocaTE THIS ovERcuRRExr OEVIDE. CROSS SECTIONAL AREA CALCULATION' MA I ' THE WARNIN. _NtB)OR I A G WITH 11021(B). °u..1, EEPTDN:ECU&ENTWDH BUSRS OR CENTER FED PNBOARDS ARE HOTADORESSED BY THIS CROSS AL ARE FKTHHN.LL2USLIU.; M.ALV AREZ FR N. CROSSSEC'MO AM OF I'TU OOLFI %. _---- —� -- NEC:(GUS RATING)%12-(MAN BAEAKER)•120%RULE (0202810.79)x100-25.7%.40% °N.T.S. THE NEC GNESYOU THE CHOICE OF FOUR METHODS FOR ENSURING ELECTRICALCONTINUFYAT SERNCEEOUIPMENT. FLORIDA CODE SUMMARY S1. V RACEAYS.ANDSERVICECONDUCTORENCLOS EW{E922(B): 0. AJMP r2Wl4EF2S.80NDMEfAECAUSETHE SESERNCENEUTRAONDUCUCTOR.THISRTMEEFSAMAIN BONDING COVER JURRER(25024(B)ANDTHEPO.E.BECAUSETHE (0),YOU DDNTR.CONDUCTORLANE ESTHETGRONEGROVNO FAULT _ CURRENT PAM TON PVCCOER$UPPNTAININGS WCE-ENTHAVETN CONDUCTORS EOUIPM(AXI) OUNOING + - CONDUCTORWITHINNCCONOVATEMETALFIACRVICE-EOMETA ENCLByTH EADEDM3S2.60°t21. FIRE BUILDING ELECTRICAL --I-- 2„THREADEDLEBS FITTINGS.TERMINATEMETPL MCEWAYb TO METAL ENCLOUSUREB BY THREADED MUB$ON T ENCLOU$URE$(IF MANE W g FTYGMR%gAn M TA AWAYS TOMETANCOUSURFS BY THREADLES FWGS(F ME TIGHT). FL Fie Prevention y 4. OTHER LISTED DEVICES.THESE INCLUDEBONDINGTYPELOCMMS.BUSHINGS,WEDGES,OR BUSHINGS WITH BONDING Code6thEdition& 2017 FBC,6TH 2014&12017 NEC C-1 JUMPERS. NFPA 12015 Ch.11 _ f NOTE:IN THE EVENT OF CONFLICTING REGULATIONS THE MOST RESTRICTIVE SHALL.PREVAIL