Loading...
HomeMy WebLinkAbout20-815 . . v wz City of Zephyrhills PERMIT NUMBER 5335 Eighth Street y . Zephyrhills, FL 33542 BG11-00081 2020 Phone: (813)780-0020 �l Fax: (813)780-0021 Issue Dot . 10/20/2020 Permit Type: Building General (Residential) Pr,,operty Number > . _ Street Address, 35 25 210120 00000 0180 7643 Merchantville Circle Owner Information _ F'e m tlnformation Contractor Information _ Name: JEREMY PAZ Permit Type:Building General(Residential) Contractor:VIVINT SOLAR DEVELOPEF Class of Work:Electric Service Replacement/ LLC Address: 7643 Merchantville Cir Building Valuation:$3,660.80 ZEPHYRHILLS,FL 33542 Electrical Valuation:$14,643.00 Phone: (727)423-1618 Mechanical Valuation: Qi�/Div Plumbing Valuation: Total Valuation:$18,303.80 Total Fees:$257.63 Amount Paid:$257.63 Date Paid:10/20/2020 10:59:42AM Project Des'°�'�c(ription INSTALLATION PV SOLAR ROOF MOUNT �4pplication Fees ': . Electrical Plan Review Fee '$56.61 Electrical Permit Fee $113.22 Building Valuation Fee $29.50 Building Permit Fee $58.30 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. I "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRA 0 SIGNATURE PE IT OFFICE PER EX RES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Permit No. 1 .� Parcel tD N.3S--G!-2I r 012 0 O00 O ' O t of-V NOTICE;OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement 1. Description of Property: Parcel Identification No.. Street Address: /C H'� 'N6C)Ia T Vt f 1 .Z C �N I L 2 General Description of Improvement. Installation of a roof-mounted solar photovoltaic system 0. CC31 '" L 3. Owner Information or Lessee information if the Lessee contracted for the improvement W O �6 p��Nameti,Pi���W�V-VI 1 l i m •• v GN zit k�/l ,li 1� tKL 11 r1 u Address City State a 0 8 Interest in Property: 3 L Name of Fee Simple Titleholder. R0 y (If different from Owner listed above) -[fl °f m N a 4. AddreContrss Vivint Solar Developer, LLC City state .W—a m n m Nu) L r� Name m m m M 5100 W Hanna Ave Tamoa FL-33634 N�N N " 0 Address City State N Q V Contractor's Telephone No.: (813)359-0634 y Y 0 5. Surety: _� ° ••Y to Name ty ° (� •r 2r m O Z IL Address City State Amount of Bond: $ Telephone No.: 6. Lender. Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Name Address City State Telephone Number of Designated Person: 8. In addition to himself,the owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement(the expiration date may not be before the completio�n/q/f nstru tion nd final ayment to they contractor,but will be one year from the date of recording unless a different date is specified): / ! c � � WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMGACEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencem tInd that facts stated therein are true to the best of my knowledge and belief. .j STATE OF FLORIDA r ! COUNTY OF PASCO 11��/ll, Signature ot(Owner or s as,or Owner's or Lessee's Authorized Officer/Dire or/Partner nager 2 l Signatory's Tdle/Office n (� (� The foregoing instrument was acknowledged before me s✓1 day of y 20�0by �� `/7 f a—z— .afs- ovrL-eA (type of authority,e.g.,officer,trustee,attorney in fact)for r+dam 1=G � (name of Pady on behalf of vtom instr mentwas executed). Personally Known E]OR Produced Identificafon Notary Signature p (�,,.r ' Type of Identification Produced D L Name(Print) /fin+ yy ` c-1 k>rw, ^0 ctarbotary Pul fic State thA t 6ny Barbone. Nk CAAyComlmiasiott G&M383 PlrEkpifey 03/01=4 wpdatatbcs/noticecommen cement_pc053048 Y STATE OF FLORIDA,COUNTY OF PASCO THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT' ON FILE OR OF PUBLIC RECORD IN THIS OFFICE oT1 W ESS MY HAND AND OFFICIAL SEAL THIS e DAY OF 2 ` .r�s 4 NI AREZ-SO LES, LERK&COMPTROLLER R�drdi `"�", .,L f �,✓ DEPUTY CLERK Building Department Date Received r�mactfbrp" Phone Owners Name rc ,1-4q PAZ Owner Phone Number Owners Address ,3 MroCq#qNrvT.i tj eik. Oworph.eNumber i Fog Simple Titleholder Name Owner Phone Number F Fee Simple Titleholder Address A JOB ADDRESS /_tfle— Loro SUBIONISION PARCEL (011TAINED FROM PROPERTYTAX NOTICE) RWORK PROPOSED N CONSME� ADDIALT SIGN M DEMOLISH INSTALL REPAIR PROPOSED USE = SFR comm OTHER I TYPE OF CONSTRUCTIONBLOCK FRAME STEEL = I DESCRIPTION OF WORK 1A1,VM1_Lq UO IV O.,r pV Sotpp pplUgL �VdTF BUILDING am SO FOOTAGE "EIGHT 6z . . . . . . . .. . . . BUILDING VALUATIONI OF TOTAL CONSTRUCTION �jELECTFUCAL AMP SERVICE = PROGRESS ENERGY Q W.R.E.C. =PWMSING IS =MECHANICAL is VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING M 'SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY [VrVrAj -, OUM REUEll1P> k 7 SIGNATURE REGISTERED I Y/ N I FEECURREK LELN J Ad&SSS JVfjd view FV IV C Vr �LW&Wd ELECTRICIAN COMPANY V-6�Z sagg h-ealagcR' I SIGNATUREREGISTERED I Y/ N I FEacuRREN /N I A.M. 1�1,00 Id.dANAM Avr "PA-1 r-61?'0fj& PLUMBER COMPANY F SIGNATURE F7 REGISTERED YIN I FEE CURREN Address License# MECHANICAL COMPANY REGISTERED ECURREn =SIGNATURE Address UCemro#F OTHER - COMPANY SIGNATURE REGISTERED I YIN I FEECURM LILN J Address i License 11111111111 IIII'll I off fill 11111til fill RESIDENTIAL A%3ch.(2)PictPlans-,(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Perm far new construction, Minimum ten(10)worldng days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit forsubdivisicnallarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Ufa Safety Page.(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal data. Required onsde,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.Ali commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ol.ctigg Fill out application completely. Owner&Contractor sign back of application,notarized It over$2500,a Notice of Commencement Is required. (AIC upgrades over$7500) Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authortdng some I OVER THE COUNTER PERMITTING (copy of contract required) Rerooft if shingles Sewers Service Upgrades A/C Fences(PlattSurvey/Footage) Driveways-Not over Counter if an public rcadways-needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not ilcensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Petico County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractors) sign portions of the'contractor Block'of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use In existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89417 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be Identified at the time of permitting. It Is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a'cartificate of occupancy'or final power release- If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to,permit issuance. Furthermore,if Pasco County Water/Sewer impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$Z500.00 or more,I certify that 1, the applicant have been provided with a copy of the 'Florida Construction Lien Law—Homeowner's Protection Guider prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws;regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes,zoning regd'lations, and land development regulations In the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to Identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads,Weiland Areas and Environmentally Sensitive Lands,Water/Waslowater Treatment : Southwest Florida Water Management District-Wells, Cypress Bayheads, Welland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health &Rehabilitative ServicestEnvimnmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agepcy4sbestos abatement. Federal Aviation Authority-Runways. i I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone`V"unless expressly permitted. - If the fill material is to be used in Flood Zone *A, it is understood that a drainage plan addressing a "compensating volume will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. i - If the fill material is to be used In Rood Zone"X in connection with a permitted building using stem.wall construction,)certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fit will not adversely affect adjacent properties. If use of MI is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in,good With to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing,signs,wells, pools,air conditioning,gas,or other installations not specifically included in the application. A permit issued shall be construed to be,a license to proceed With the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVIEMEN M TO PR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDGR OR AN 3:TOREFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F* 3) OWNER ORAGEN CONTRACTOR d IN Subscribed and swam to(or affirmed)before me this Oftf-V;g by e 017MW- by WK0 istalia. to me or d Who isiare personally knovm to me or hasthave produced as identification. As identification. Notary Public Public CamNa. Commission N Commission No. WA V W Wth V' �d d Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Notary Put*C Stele of Florida James miWon Quillen aExpExpiresMy Com HS s 09/25/2024 012750 iv' `�,, 1800 IN Ashton Blvd. ® ' ::,i Lehi, UT 84043 Structural Group J. Matthew Walsh, PE Kirk M.Nelson, SE Samuel Brown,PE- Civil Director of Engineering Structural Engineering Structural Engineering james.walsh@vivintsolar.com kirk.nelson@vivintsolar.com sam.brown@vivintsolar.com September 09,2020 Re: Structural Engineering Services Paz Structure 7643 Merchantville Cir,Zephyrhills, FL S-6448758; FL-01 To Whom It May Concern: i We have reviewed the following information regarding solar panel installation on the roof of the above referenced structure: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. j Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: j A. Description of Structure: I The existing structure has typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Southern Pine#2 or better with standard construction components. The designed areas of the home consist of the following framing methods: • Roof Sections: Prefabricated trusses at 24" on center. Survey photos indicate that there was free access to verify the framing size and spacing. B. Loading Criteria i 14.66 PSF= Dead Load (roofing/framing) 3.00 PSF= Dead Load (solar panels/mounting hardware) 17.66 PSF=Total Dead Load 20 PSF= Roof Live Load (based on local requiremi nts) Wind speed of 145 mph (based on Exposure Category D-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C. Solar Panel Anchorage 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. • EcoFasten Solar Installation Manual, which can be found on the EcoFasten Solar website (www.ecofastensolar.com). 2. The solar panels are 1'/2" thick. At no time will the panels be mounted higher than 10" above the existing surface of the roof. Page 1 of 2 ' i t s - j -31 ., j i i 3. The following mounting types shall be used. Please refer to the mounting details for the associated mounting method requirements. Based on our evaluation, the uplift demand is less than the maximum allowable per mount and therefore is adequate. • Rock-It: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) of timber construction specifications for Southern Pine is 235 Ibs/inch penetration. 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2017 FBC 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10. These spacing requirements apply to all mount types indicated above. The following values have been verified by in-house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections should be staggered, where possible, to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 48 48 48 48 48 48 Cantilever in 16 16 16 15 14 15 D. Summary Based on the above evaluation,with appropriate panel anchors being utilized, the roof system designed on will adequately support the additional loading imposed Iby the solar panels, if installed correctly. This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida Building Code- Residential 6th Edition, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. i Regards, \\\��P,��VIE VV`N \ J. Matthew Walsh, PE * N 84R 3y FL License No. 84923 � _ p STATE OF /� �jO�F, 'ctORIV ' ��� ss/ONAL'�?G��\ �/111111111\ 09/09/2020 i Page 2 of 2 v,vi n A i • a vivin �< <�� � 1c�Of1 V'�Ashton Blvd. t�'..�y �<�-- . Lehi, CST 84043 Structural Group J. Maifhew Walsh, PE Kirk M.�Ne/son, SE Samuel Brown, PE-Civil Lk ector of Engineering Structural Engineering Structuraf Engineering james.waish@vivintsola,r.com ki k nelson@vivintsolar com sam.brown t@vivintsolar com Structural Design Criteria Project Address Date: September 9,2020 Paz Residence 7643 Merchantville Cir Zephyrhills,FL 5-6448758 Residencer E a si9�� Risk Category II y Roof Area 3084 sf * N 4 ; Upper Floor Area 0 sf — Number of Stories 1 10 STATE OF ,� z Mean Roof height 15 ft —i ® '. Upper Floor height Oft ��j� �' �tOR1OP='�G����� Location Parameters AL Latitude Latitude 28.268349 ���igy291Wq►►\��\ Longitude -82.17918 Site Class D(Default) Risk Category II j Existing Gravity Parameters Roof Dead Load 5 psf Composite Shingle 2 psf 3/4"Plywood,Sheathing 2 psf Roof Framing @ 24 in. o.c. 3 psf Ceiling,Mechanical,Electrical 2 psf Miscellaneous 15 psf TOTAL Roof Live Load 20 psf Wall Dead Load Ground Snow Load 0 psf 8 ft Wall Height Flat Roof Snow Load 0 psf 300 ft Wall Length 12 psf Wall Weight New Gravity Parameters Roof Dead Load 3.00 psf Solar Panel Weight Roof Live Load with Solar Panels 0 psf Roof Slope Factor 0.7 Roof Slope Factor(ASCE 7-10 Fig.7-2b) Roof Snow Load 0 psf I ASCE 7-10 Eq.7.4-1 Seismic Parameters SS= 0.068 g 0.2 sec Spectral Response Acceleration SI = 0.035 g 1.0 sec Spectral Response Acceleration Fa= 1.600 g Site Coefficient from ASCE 7-10,Table 11.4-1 F = 2.400 Site Coefficient from ASCE 7-10,Table 11.4-2 SDS= 0.073 g� Short Period Design Spectral Acceleration SDI = 0.056 g; 1 Second Period Design Spectral Acceleration Page 1 of 4 Wind Parameters Wind Speed 145 mph Exposure Category D Roof Angle, 0 27.0 deg Product Information No.of Panels 31 Weight 3.00 psf, including mounting system Installed Area 562.7 ft2 No.of Connectors 41 Total Existing Roof Load=Roof Dead Load+(Roof Live Load or Snow)x Spacing 69.32 plf Total New Roof Load=Roof Dead Load+Added Dead Load+(Roof Live Load or Snow)x Spacing) 35.32 plf Change in Demand=(Total New Load-Existing Load)/Existing Load -49.05% Total New Gravity Loads are less than Existing Loads. OK 2015 IEBC Section 707.2 states: "Where addition or replacement of roofing or replacement of equipment results in additional dead loads,structural components supporting such reroofing or equipment shall comply with the gravity load;requirements of the International Building Code. EXCEPTION 1.Structural elements where the additional dead load from the roofing or equipment does not increase the force in the element by more than 5 percent." i 2015 IRC Section AJ501.4 states: "The minimum design loads for the structure shall be the loads japplicable at the time the building was constructed,provided that a dangerous condition is not created.Structural elements that are uncovered during the course of the alteration and that are found to be unsound or dangerous shall be made to comply with the applicable requirements of this code." 2017 FBC Section AJ104.1 states: "Detached one-or two-family dwellings that are not irregular buildings under Section R301.2.2.2.5 and are not undergoing an extensive reconstruction shall not be required to be evaluated." i Page 2 of 4 ® } v' '`' ``� � 1800 W Ashton Blvd. :� � 'i Lehi, UT 84.043 Structural Group J.Matthew Walsh,PE Kirk M. Nelson, SE Samuel Brown,PE-Civil DiredcrofEngfneerfng .Structural Engineering Structural Engineefing james.waish@vivintsolar.com kirk.nelson@vivintsolar.com sam.brown@_vivintsolar com Mount Spacing Calculation ASCE 7-10 Simplified Procedure for Components and Cladding NDS Section 12 I ICC Code Cycle 2015 Wind speed (V) 145 mph Exposure Category D Roof Slope (0) 27.0 deg Effective Wind Area 20 sf Least Horizontal Dimension 0.00 ft Adjustment Factor 1.47 Topographic (Kt ) 1 Panel Dead Load (Pd) 3 psf Ground Snow Load 0 psf Flat Roof Snow Load (pf) 0 psf ASCE 7-10 Eq. 7.3-1 Slope Factor(CS) 0.72 ! ASCE 7-10 Fig. 7-2b Roof Snow Load 0 psf PfCs Total Dead Load (D) 3 psf ! Panel Dead Load + Roof Snow Load I Portrait Landscape Vertical Spacing (L) 67 in I 391in I Based on length of the panel Wind Pressure Zone 1 Zon;e 2 Zone 3 Lookup Pressure (Pnet30) 31 psf 49 psf 89 psf ASCE 7-10 Fig. 30.5-1 Uplift Pressure W 46 psf 72 sf 131 psf \*Kzt*Pnet30 i I Fastener Type 5/16 in Yield Equations NDS Table 12.3.1A Diameter 5/16 in I m ; 648 Ibs Fasteners 1 I s 1222lbs Embedment (Dpen) 2 1/2 in II 359 Ibs Load Duration (Cd) 1.6 III_m 372 Ibs Pullout per Inch (W) 235 lb/in III s ! 389 Ibs IV j 1 336lbs Uplift Capacity 939 Ibs DpenCdW Shear Capacity 336 Ibs Based on equations from NDS 12.3.1A Page 3 of 4 c VI ' t �� , '� 1800 W Ashton Blvd. . �! f Lehi, UT 84043 Structural Group J.Matthew Walsh,PE Kirk M.Nelson,SE Samuel Brown,PE-Civil Director of Engineering Structural Engineering Structural Engineering james.waish�[,3a vivinmolar com kirknel4on@vivintsolar.com sam.brown c@vivinrsolar corn i i Mount Types: Uplift Shear Fasteners (Capacities based on manufacturer testing) Rock-It 547lbs 390lbs 1 Fastener Capacity 939 Ibs 336lbs Controlling Capacity 547lbs I 3361Ibs Portrait Zone 1 Zone 2 Zone 3 Uplift 45 in 43 lin 46 in Shear 530 in 798 in 1595 in Capacity Manufacturer or AHJ 48 in 48"in 48 in L*SIN(6)*D Controlling Spacing 45 in 1 43;in 1 46 in Landscape Zone 1 Zone 2 Zone 3 Capacity Uplift 78 in 73�in 79 in L*0.6(D-W) Shear 909 in 1367 in 2734 in Capacity Manufacturer or AHJ 48 in 48;in 48 in L*SIN(A)*D Controlling Spacing 48 in 48!,in I 48 in Tributary Area (Atrib) Zone 1 Zone 2 Zone 3 Mount Spacing *Vertical Spacing Portrait 21 sf 13 isf 7 sf Landscape 13 sf 9 sf 4 sf I Demand in Uplift Atdb*0.6(Pd-W) Portrait 547Ibs 547 Ibs 547Ibs Landscape 338lbs 3591lbs 333lbs Capacity in Upllift 547 Ibs 5471Ibs 547 Ibs Max Utilization=1.00 Demand in Shear Atrib*SIN(A)*D Portrait 29lbs 18lbs 10lbs Landscape 18lbs 121bs 6lbs Capacity in Shear 336 Ibs 336 1Ibs 336 Ibs Max Utilization=0.09 I Page 4 of 4 , 1 ® �SOlar. c- fan . tK i { { M,t��aC�t M000 pER�R,'e�d+�le NOD pCK NVigh density P►LL"BL 1 320 W r 340 VV 0335 CS,,N"32OI32 i MORE POWER ' .oduct`Narranty on materials the light absorption area, to 20.1 b°I° _17 enhanced p MaXimite P ,1lfor Lmanship module efficiency u uPTo ; and < years ClPfpaX)- `°�„,•A....«'° coefficien _ ,ow temperature I �<,s r oyrer output warranty* f 2rj ' iinea p statement years 1.imitedWartantY Qlerance � „pccordingtOtheaPPlicableGanadianSolar•••-••,---• TI Better to er shading ...........+ T SgSTEM GE FICATEv R NAGEMEN en, . system ement system Mp` uality mana5 eetal man 9 health&sa r! a e ISO 9001:20151 Q ards ironm for occip MARE RELIABLE ISO 14001:24151 Stand for em' atwna OHS '`1g0p1:200'7 I international standards L,ower internal current. I PRODUCT CER•nFICAIE5* us ploridal lower hot spot temperature ' CE I MCs US)I ESEC VDE I CEClisted ton, IEC 612151 IEC 61730.erformanGe' lnsn,a11re9 C61215p IIECb271b:VDE 11mlted- UI.17031IE 61761 ED2:VDE C Cell cr ce tfi module reliability UI 1703:CSR I LE enhan Takee"Way �� !Q')GERT tactyour tease con to 5400 P a' arkets'P iicable to the U ` ents in different m ,now load p 4 pVE of us uirem euflc certificates aPP •. Heavy u to 2400?a* ' L t certification t tatwe for the to be used. ............. wind load P differen reshe ducts are to ` ps there are an Solar saleI h the P V iding high iocal Canad the region in d to Pro and gerviee5 to Products CANApIAN SOLARI%C.is comnll e soiutions a uality ups,solar system odule supplier for q quality solar Prodd world.No-5 M Customer Insight ` the in IN odule d manufacturer custorners arou ratio ,Norld er{ormancelpfice er an d the 'er and p AS a leading pv prol38 de deployed aroun Survey with over odules .................. { of solar m ................ since 2001. ........................... � .................• adiansalar.com supP ort@can E6.Canada,• com, Manual. .............' �N canadiansolar. Ieaserefertolnstailation •••-.. +pat detail Information,P (.11 K 1 ........... r... AN SOLAR I e W est,Guelph, Ontario 545 Speedvale Avenu ENGINEERING DRAWING(mm) CS1H-330MS/I-V CURVES Rear View Frame Cross Section A-A A A _IQO_ 12 12 --35 35 to ---- -- 70 --------- --- ------------------- Iul 8 ----- - --------'--- --------- _._ 8 a-4-1 7 _ _. _ _- _ _ _._--.--. 7 q.--..... .___- 4 Mounting Hole 2 ._ _ .._._ 2 _________ _______ ____ 5 10 15 20 25 30 35 40 45 50 5 10 15 20 25 30 35 40 45 50 -- �crouna•ng Hole .A -(-- 1000 W/m' 5°C �� 11 800 W/m� 25°C S -- --- 400 W/m' 65°C 092 ELECTRICAL DATA STC* MECHANICAL DATA CS1 H 320MS 325MS 330MS 335MS 340MS Specification Data Nominal Max.Power(Pmax) 320 W 325 W 330 W 335 W 340 W Cell Type Mono-crystalline Opt.Operating Voltage(Vmp) 36.2 V 36.6 V 37.0 V 37.4 V 37.8 V Dimensions 1700 x992 x35 mm Opt.Operating Current(Imp) 8.85 A 8.88 A 8.92 A 8.96 A 9.00 A (66.9 x39.1 x 1.38 in) Open Circuit Voltage(Voc) 44.0 V 44.1 V 44.2 V 44.3 V 44.5 V Weight 19.2 kg(42.3 Ibs) Short Circuit Current(Isc) 9.41 A 9.45 A 9.49 A 9.53 A 9.57 A Front Cover 3.2 mm tempered glass Module Efficiency 18.98% 19.27% 19.57% 19.86°% 20.16% Frame Anodized aluminium alloy Operating Temperature -40°C-+85°C J-Box IP68,3 bypass diodes Max.System Voltage 1000V(IEC/LlQ Cable 4.0 mm2(IEC),12 AWG(UL) TYPE 1 (UL 1703)or Cable Length 1350 mm(53.1 in) Module Fire Performance CLASS C(IEC 61730) (Including Connector) Max.Series Fuse Rating 15 A Connector T4 series or H4 UTX or MC4-EVO2 Per Pallet 30 pieces Application Classification Class A Per Container(40'HQ) 780 pieces Power Tolerance 0-+5 W -Under Standard Test Conditions(STC)of irradiance of 1000 WW,spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA I NMOT* TEMPERATURE CHARACTERISTICS CS1H 320MS 325MS 330MS 335MS 340MS Specification Data Nominal Max.Power(Pmax) 236 W 240 W 243 W 247 W 251 W Temperature Coefficient(Pmax) -0.37%/°C Opt.Operating Voltage(Vmp) 33.4 V 33.7 V 34.1 V 34.5 V 34.8 V Temperature Coefficient(Voc) -0.29%/°C Opt.Operating Current(Imp) 7.07 A 7.11 A 7.14 A 7.17 A 7.20 A Temperature Coefficient(Isc) 0.05%/°C Open Circuit Voltage(Voc) 41.0 V 41.1 V 41.2 V 41.3 V 41.5 V Nominal Module Operating Temperature 44±3°C Short Circuit Current(Isc) 7.60 A 7.63 A 7.66 A 7.70 A 7.73 A *Under Nominal Module Operating Temperature(NMOT),irradiance of 800 W/m'•spectrum AM 1.5,ambient temperature 20°C,wind speed 1 m/s. PARTNER SECTION .......................................................................................................... The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement.Canadian Solar Inc.reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. .........................................................................................................i ................................................................................................................................................................................................................................................ CANADIAN SOLAR INC. 545 Speedvale Avenue West,Guelph,Ontario N1 K 1 E6,Canada,www.canadiansolar.com,support@canadiansolar.com December 2019.All rights reserved,PV Module Product Datasheet V5.583 EN g Sin �-le Phase -Inverter • C with HD-Wave Technology m for North America TI SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE1140OH-US m YEAR p solar, •._ -.-:{�wo.,� WARRANTY O solar3 i •••• Soso • ® 0 lilt ' - W - Optimized installation with HD-Wave technology / Specifically designed to work with / Extremely small power optimizers / Record-breaking efficiency / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data,ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) / UL1741 SA certified,for CPUC Rule 21 grid compliance solaredge.com solar 8 9 � ® Single Phase Inverter' with ®-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000.H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US SE300GH-US811 111 .00O .11 1111 411 OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ i ✓ ✓ Vac (211-240-264) AC Output Voltage Min.-Nom:Max. ✓ ✓ ✓ I Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.50) Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output _ 16 I 24 48.5 A Current @208V GFDI Threshold 1 ' A Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 I Vdc Maximum Input Current @240VI2' 8.5 10.5 1 13.5 16.5 20 27 30.S Adc Maximum Input Current @208VI21 - 9 1 - 13.5 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency gg 99 @ 240V % 98.5 @ 208V Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional(" Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL169913,CSA C22.2,Canadian AFCI according to T.I.L.,M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class 8 INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG f 1"Maximum/14-4 AWG DC Input Conduit Size/ of Strings/AWG Range 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 7.3/540 x 370 x 185 In/ (HxWxD) � min Weight with Safety Switch 22110 25.1/11.4 26 2/11.9 38.8/17.6 Ib/kg Noise <25 <50 I dBA Cooling Natural Convection Operating Temperature Range -13 to+140/-25 to+600I(-40°F/-40°C option)(" -F/-C Protection Rating NEMA 4X(Inverter with Safety Switch) "For other regional settings please contact SolarEdge support -1 A-higher current source may be used;the inverter will limit its input current to the values stated Revenue grade inverter P/N:SExxxxH-US000NNC2 "For power de-rating information refer to:https://wmnsolaredge.com/sites/default/files/se-temperature-deratir.g-note-na.pdf -40 version P/N:SEx H-USOOONNU4 t SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All m other trademarks mentioned herein are trademarks of their respective owners.Date:03/Z019N01/ENG NAM.Subject to change without non R9®111iSce. ill