Loading...
HomeMy WebLinkAbout20-840 I \ r n on City Of Zephyrhilis PERMIT, -— 13ER 5335 Eighth Street Zephyrhills, FL 33542 BGR-000840-2020 Phone: (813)780-0020 ;{ Fax: (813)780-0021 Issue Date: 10/06/2020 Permit Type: Building General (Residential) Property. Number Street Address 1126 210010 19300 0050 5137 9Th Street Owner Information Permit Information Contractor Information Name: JOY MURPHY Permit Type:Building General(Residential) Contractor:A. BARTLETT ROOFING OF Class of Work:Reroof CENTRAL FL. INC. Address: 5137 9Th St Total Valuation:$8,986.00 ZEPHYRHILLS,FL 33542 Total Fees:$127.39 Phone: (813)713-0997 Amount Paid:$127.39 Date Paid:10/7/2020 12:03:35PM V Project Description 0 Application'Fees Building Plan Review Fee $42.46 Building Permit Fee $84.93 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. a_c� aa��� CONTRACTOR SIGNATURE PE r IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting caeaeaa111 caerr[ Owner's Name Joy Mur by Owner Phone Number 813-713-0997 Owner's Address 1 5137 9th Street, Zephyrhills Owner Phone Number Fee Simple Titleholder Name F Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 5137 9th Street, Zephyrhills, FL 33542 LOT# SUBDIVISION PARCEL ID# 11-26-21-0010-19300-0050 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK New TPO Roof w/Insulation BUILDING SIZE SQ FOOTAGE HEIGHT I� =c C eZ ccza rs¢crc<sc r�r>m =BUILDING $ 8,986.00 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ �� =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION A6 =GAS ® ROOFING 0 SPECIALTY = OTHER C161 am( J l/ FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO - 1 I BUILDER COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN Y/N Address License# ELECTRICIAN- COMPANY SIGNATURE 1 Y/N FEE CURREN Address License# PLUMBER COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN Y/N Address License# OTHER COMPANY A Bartlett Roofing&Construction Services,LLC SIGNATURE REGISTERED I Y/N FEE CURREN I Y/N Address 38408 Ave Ze h rhills 33 License# CCC 1331965 t���etttre•�ri>e®,3ee�rti��c®®�r��eti���ti �tit�ea�®r�r����etEe>at��aE� erate�t RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisionsllarge projects' COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. ------- ------------- Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized-letter from owner authorizing same- OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW I,a� 813-780-0020 City of Zephyrhills Permit Application Fax-813-7e0-0021 i Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may,apply for the intended work,,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired'a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy',or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental'Health Unit-We'fi, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit Issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF kTO NT MAY RESULT IN R PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU TAIN FINANCING, SULT TIC WITH XQUR LENDER OR AN ATTORNEY BEFQRE RECO FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed ands n to(o me this C Who istare personally known to me or has/have produced Who is/are personally kno o me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. commission No. GG211065 Tina M Prater Name of'Notary'typed;printed or stamped Name of Notary typed;printed or stamped' Florida Building Code Online 9126119,4--24 PM t *41 A, T INN T'I ..... ......... SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats 4 Facts Publications Contact Us OCIS Ste Map Links Search li Product Approval USER:public User !i-Application 0Gt2II Fl. FL 152�93a R35' Appilration TVDa Revision Code Version 2017 Application Status Approved Comments Archived Product-Manufacturer GAF ALL WORK SHALL COMPLY WITH Address/Phone/Email I Campus Drive CODES FLORIDA BUILDING CODE PREVAILING Parispipany,NJ 07054 NATIONAL ELECTRIC CODE, (800)766-3411 AND THE CITY OF ZEPHYRHILLq m5tieh@gaf.com ORDINANCES Authorized Signature Robert Nleminen lr6ith@nemoatc.com Technical Representative William Broussard Address/Phone/Email I Campus Drive Parsippany,NJ 07054, REVIEW DATE OCT 0 5 20 (800)766-3411 TechnicalQuestionsGAF@gat.c.q'Ty OF ZEPHYR;' dL? Quality Assurance Representative PLAN EXAMINER Address/Phone/Email Category Roofing Subcategory Single Ply Roof Systems Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nleminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/17/2021 Validated By John W.Knezevlch,PE Validation Checklist-Hardcopy Received Ce;7tiricate of Independence Referenced Standard and Year(of Standard) Standard ASTM D6878 2011 FM 4470 2012 L hilps./Itioridabuilding.org/t)r/t)r�.aDp-dti.af;ox?naram=wGEVXQwtDquwVcULas7wTHaOxy0c%2bdOLPPr3VUSdsqmIM7lC3PGghg%3d`/`3d Page 1 of 2 Florida Building Code Online I 9/25/19,4:24 PM i FM 4474 2011 TAS 114 2011 i� Equivalence of Product Standards Certified By E Sections from the Code iI Product Approval Method Method 1 Option D l Date Submitted 06/19/2019 Date Validated 06/19/2019 Date Pending FBC Approval 06/22/2019 Date Approved 06/1312019 Date Revised 08/14/2019 Summary of Products_, FL#2 Model,Number or Name Description 5243:1 EverGuBtd TPO Single-Ply Root Single-ply,thermoplastic polyolefin roofing systems Membrane Systems i.tmits of use, Installation Instructions Approved for use in HVHZ:No Ft;7''1,,_?•a5. It_ZU_O2- ,Fl,4 a _7 1, FI 52ei-R- r•If Approved for use outside HVHZ:Yes Verified By:,Robert Nleminen'PE-59165 Impact Resistant,N/A Created by independent Third Party:Yes Design Pressure:+N/A/-502.5 'Evaluation Reports,. other. 1.)The design pressure noted In this application =a « _tea 7(Lu r „r al F;5?r93-R-45 . relates to one specific assembly In the ER Appendix.Refer to Created by independent Third Party:Yes the ER Appendix for all systems and associated max.design pressures.2.)Refer to ER Section 5 for Uinits of Use Sant, is::2601 Blair Slone Rod,Tallahassee EL 37399 Fhnne:AS •487.1824 The State of Florida is an ANEW employer.Capyn hq t 20117.70t3 etAte Of Mr4N.::Pnvary 5!!At�nt:;Aceessiblilty Stem--m..t::ReflMd Sutemrnt Under Florida taw,er"t oddres'ses are public records.it you do not want your e-mail address released in response to a public-records request,do not send efeceonle mail to this entity.instead,contra the office by phone or by tratirional mail.it you have any'quesbons,please Contact aso.-wa:;9s.'Pursuant to Section 455.275(i),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address)(ttiey have one.The email%provided may be used for OWN communication rinn the tonsee.ha never email addressesare public record.u you do not isish to supply a personal address.please pro.vide the Department with an email address watch can be made avallabto to the public.To determine If you are a pcensee under Chapter 45S,F.S.,please Click acre_. Product Approval Accepts: (.tfi(ili l.r;lCi .Sate E https://floridabuliding.org/pr/pr_app_dtl.aspx?patam=1)GSVXQwt0quviVCULas7%yTHoOxyQe%2bdOLPPrSVUSdrgmfM7lC3PGghg*/`SdS:3d Page 2 of 2 � ! .77 i t s �_... t._ _.. 9gattm Cade IriaU ian(hobo 24) it Covir. - f IJDP tdra (NoteB) TV" A1tad1 bktamixare Fesmeon AtWdn@M Itzsj Min,10/32-Inch plywood One or more layers.arty Prelun. DriH•Tec014 Fastener with Ddll•Tec 21n.Double. 6-Inch o.c.within SS•Irech wide leps spiced I24.5•Incfi tV•57. at max.2ItSpam combination, atuchod EvatGuarGTPO 9arbedXHDPiate4 o.e and senled.ovttha1.75•indr heat vrd& -05'-0 mht,19/31•inch'plywood One or more layers,any Pr6m. DrIN•Tec 014 Fsptaner,vlth Ortli•Tec 2 in,Double 6-Inch o.c.within 64ach wide tops spxed 55d4tch ox.and W58' at max.2 ft spans combination attached EverGuardTPO earbed)ND plates sealed with a 1.75•irch heal weld. 52S 0 R•Ter 1�!Ftendtt!}tilb:Te¢*2;n�Ooubla 5� Cn�7Si'3nc p syocd 0 arrstar2t es,_,�iY SI' EvarGu ,FtiQ Oarh2d96lDFlaY sty`ecediefircn' tt to 1`?mcrrosn efisllt101abrSs91 } G 52.5'. ;?armzx. i5 cp comhinauon ~lathed » fcsvaiooit.p�sst5ja�`�seated�v:ha l:Srnrlr hem-wadi g vaorJjn is mtnlmGm;3-lach'emedemtnt - " 0611-Ter.614 Fastener with Drill-Tee 2.3/4 In. Mln,.15/32•lnch plywood One or more layers,arry Prelim. 12•intb o.c.whhin6minchwide4.ps spaced 4&inch o.c. Its EverGuard TP0 Barbed SXND Plates fastened through dick t0 67.5 nt max.2 parrs combination altacMd en8age wood joists,minimum Hach emedument (over wood joists)ad sealed with e1.5 indr heal weld. •R • • a a 1 $yyt Dtys Insulation Ls""*)(Nato 14) Base err Asuhor Shae1 llR4P Eta (Nata 1) Opp! . Atlads ohm Facia mis Attach E'ao1 Cam (PVQ Min.15/32 inch One or more layers, loose- GAF StormSafe Anchor DrRI•Tac R74 fastener with Drill Tec 3'Steel Plate o.c.at min.4•txh lap and Plate EvarGuard freedom r W{i1' plytaood;24"spans anycombinalion laid Sheet Wax.48-Inch wide) orOr10-Tec3In.RibbedGalvakrmePlate(Flat) laggere.ealeroowsu3ltyspecad, 1P0jseBadhared 45.0 sUga;ered center roes - - -0•Irtch W-62. oe.at minr4•Inds lap.and& ' Min.19/32•inch Oneor more lasers, Lowe. GAF StormSale Anchor Dr3 inch C.C., at two,equally spaced,t•Tec N24 Fastener with Drdl•Tec 3 its.Ribbed EveiGuard Freedom 60.0• plywoud,2a'spans anpcombinatian laid Sheet(hem.48-indtwide) Gabraluma Plate(Fla!) staggeredcentercmvs TPO/se13 1hered j r 1 • OVITR r qQ0 • Spstein Veds boFC�voer 1y No, (rota 2) tlaamhsaae Fasdetsars Attattlrtent Ip�f MIn.19132Inch plywood at 6-Inch o.c within 5.5dnchwide laps spiced 1145•Inch a.C.and W63. Min.2 It spans EverGuardTPO Drill-7ec014 Fastener with Wfl-Tec 2 in.Double Barbed XND Pates seaiad w11ha 1.75 loch hoatwetd. -45.0 W6�I. Mtn:19/32-Inch plywood at EverGuardTPO Drill-7ecM4Fastener with 0411-Tec2 in.Double Barbed MOPlates 6dncho.c.within5•InchWdolopsspawdS5.1mboe.ardscaled S25 mai.2lt spans with a 1.754nch heat weld: Min.15/32-inch plywood at Drill.Tec 014 rastener arith Drill-Tec 21n.Double Barbed%HD Plates fastened 124ach o c.within frtnch wide laps spaced 4&Inch ax.(over Wes' Max.2it$par* EvetGuardTPO thro hdecktoe 60A 41 engage wood)asses)andsealedvriti>a2S-Irtchtuatweb. Min.15/32•indtphvroadat Drill•Tecal4Fasferierwithorill-Tet2.3/4in.Baroed SX14D Plates fastened through 12•Incho.e.wlthln6•Inchwide laps spaced4il-"oc.(over Wes' max.2ftspars EverGuardTPO deck toenpaewoodloists,mtnlmuml•tnchemedarrmt wood lolsts)'and waled viitsa1.54mh heat weld. •7541 HMO ETC,LLC Evaluation Report 03So6.09.QrR36 for FL5293-fi35 c Cendlcale of Authorirution 432455 6th Edition(20171 FOC NON41VM EVALUATION RcvWon 36:06/23/2619 Prepared by:Robert r$aminegPE-59166 GAF t trr6mrd TPO Shogts•Ply Raab Me nbrasw Wen s;IBM)765.3411 AppendW 1,Page 1S of 115 OEM. ® • auasaarirEe FLEXSCAL'C!t"GRADE SEAWIi f 1 PRIDE mevePAT.'E MST GET'°ND SrR- i` V Mt EVERGUM Mo TPO PROM � t �€y GRILL-TEC`TERUINATION BAIT f FASTENED 6'TIS?r ml D.C.VATI1 DTIILL•TEC-FASTENERS e S' REINFCRGEq EVtRuLMD°b"ESIcfL;NE i 3 IPERfuETEF2 h]IEE1 tF RE'3UtftEi7) I jWODD IlA2ER,S_'13].D mi;1•J' I i I102 mm)AKIN.SECUREO TD,UC_CN .ZsZr,;±;'i a EREAGYGUMO'ROOF 1N$ULATTON ROOF DECN,SU85TRAIE t 2� . 2t �y L-4CAOR,L R•G RE7SEAC CULKG('DE.SCAL:'t : y :,T j z kirmuwc-EXTENDS 1m;i'(:5:4 rnmT Baca w 41 Iq,- r`'r tEkb11NA71ON GAR MUST HE FAST EIIED°'11S2 m.I O.C.MilTWS DETML 7<FUR P1SUL ATIOn TTttIXNESS GREATER TIMN 6'p3_t A IY.RO DOATiD 6 rxOURED ON y` !i I.tEGwgCALLYFASTEN OSYSTeASONLY. i f i I.APPLY EVERGUARC'TPO LTTT EDGE SEAWTTO ALL,CUT REWFORMU TPO EWES ( iREFERTOEVF.RGUARD'DVAILII5) i (y T RNNAMON BAR;R00F EDGE;. _. t I7,T5. +10.}t7 i 172 s- o .• : o-ffnes INSULATION ATTACHMENT TABLE-MECHANICALLYATTACHED SYSTEMS (Meets FM attachment requirements') jijL*ABER OF RL%MERS Fastetstrl/board.. 1rlstifaUanTyp®.:. Board Size V*knbw 'Raid" Psrtmciaf. ...Gainer 4 x4 any 4 4. 4 11.2 m x 1.2 m) 4'x8' 112'-1.2' - Poly(so 6 6 6 (1.2n1x2:4m) (13mrr-30mm) 4'xB, (1.2inx2.4m) 22.3'(33 mm) 5 5 S Penile 44' any 4 ! 4 4 IL2mx1.2m) F 4•xa' )` any a 4 e"? Wood Fiber a•:B' ''"; aml 6 (1.2mz2.4in) e:so 4'x4' any 4 4 4 � e�$ 4-x8' l.z' 6 6 °`i: t RINI Fxtrs�ded Po�yuYie ' 6 (1.2 m x 2.4.m) (13 mm mm) § : 213'(33'ntm},;' any 4 4 4 (1.2mx1.2m) 4'xB' 112--l.2- 6 6 6 Expanded Polystyrene' (1.Z m x 2.4 m) (13 mm-30 mm) 4'x8' 21.3'(33 mm) 5 5 5 (1.2mx2.4m) Fanfold-TPOorFirece- Fanfold' 3/8'•min(10mm) 2-1=2.1.21 2-12.12 2-1-2-1-2 back PVC only d'xB' 1/d"-S/8' Gypsum Board' 11.2'm x 2.4 m) 16 mm-16 mm) 6 6 6 'Attachment requirements to meet determined uplift resistance are dependent on deck type,specific fastener,etc. 'Fanfold attachment-spacing Is for each 2'x 4'(610 mm x 1.2 m)section. "Smooth PVe must have 3/6 oz.(85/170 gr)polymat separator sheet or fleece back. 'Irciudes approved 0ens0eck':and SECUROCK Roof Board products. 83 ProductData Shdet5 "INSULATION FASTENING.PATTERNS Y X 41610 mm X 1.2 M)BOARDS 4 5 1 eSOON' • • 6 7 G„ 6.. i 18" 1811 i O • • • 1 61 i i. ///A, BARTLETT ROOFING & CONSTRUCTION SERVICES, LLC 38408 3rd Ave. I Zephyrhills, FL 33542 (813) 782-5585 C Email: Cor-eyh@abartlettroofing-.com. Lic. #CCC" 1-331-965- RESIDENTIAL • COMMERCIAL - MOBILE HOMES LICENSED - INSURED - BONDED Date Name ` ` �r h Address— Phone DESCRIPTION.`:: = AMOUNT ( �v...ov� Cor�► 12 �o Ot-t ✓oaf �' l,a�/ a &a[41-c e-0 -i4eA�- r u �5 lie els s)-a!1 Pl e w . ©(� �/} vie v u ✓G� J p0 vie✓ ' s�l�f;� �• ''P-% 86% ✓ CA r-o�c�d P �s fir' 4 ►'I'-u�►�-- QS'anc/�I;jlgr THANK YOU Your Business is Appreciated Payment upon completion unless previous arrangement made.Warranties pertain to original owner. All arrangements contingent upon strikes,accidents or delays beyond our control,Owner to carry fire,tornado and other necessary insurance. ' Our workers are fully covered by Workmen's Compensation Insurance.Customer is liable for any charges incurred in collecting this bill. 1.5%process fee will apply to all credit card transactions. Total g6 M-Ceriffed SignY %' Date ' wuaThwSraDPer100finO conhnw / ///A, BARTLETT ROOFING & CONSTRUCTION SERVICES, LLC 38408 3rd Ave; I Zephyrhills, FL 33542 (813) 782-5585 Email: Coreyh t@aba.rtlettroofing-.com- Lic. #CCC 1.33-1-965- i RESIDENTIAL • COMMERCIAL • MOBILE HOMES LICENSED -:,INSURED,- BONDED Date- Name r h Address �7 Phone To— T3—�� ei DES.CRIPT,ION. .: . AMOUNT eve ove Co r-2 42 1 e) j2 V f KO O t-f ✓e D'f a t -o ��eh 1 w6 o u s -e es 100, dee,�.,�„ > ls�,, s�-a!1 v,e( . 060 �f}� ��e� v"C' V-d 1 PO 9t r1P''/^� �� Y CA ro—K� P �S •ll THANK YOU QSDK ' A� Your Business is Appreciated Payment upon completion unless previous arrangement'made.Warranties pertain to original owner. All arrangements contingent upon strikes,accidents or delays beyond our control.Owner to carry fire,tornado and other necessary insurance. Our workers are fully covered by Workmen's Compensation Insurance.Customer is liable for any charges incurred in collecting this bill. $C' g6• O 1.5%process fee will apply to all credit card transactions. Total, 2:-Certiried ign, - 1 I Sign : Date smarurRonnno / INSTR#2020167751 OR BK10192PG1830' Page I of I 10/0712020 11:10 AM Rcpt:2212747 Reo: 10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller '41 *C)c(<D - 19':Lot).Cx:)S0 Permit No. i parcel ID No NOTICE OF COMMENCEMENT site Of Florida - County of Pasco THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,aid in accordance with Chapter 713.Florida Statutes, the following Information Is provided In this Notice of Comma I: [fir 1. Description of Property: Parcel Identifica !�Iu-Al -coo - 1 8 oc) - 0050 Street Ad Ft, -36S4a 2. General Descripflon of I promment �jeun 7po -ece-g- 3. Owner Information or Lessee Information If the Lessee contracted for the improvement CMV- isN- E. I-S F-—(- Address City V late Interest In Property., Name of Fee Simple Titleholder. (if different from Owner listed W)OW) Address 'cl state 4. contractor. A Bartlett Roofing& Construct obi Services. LLC Name 38408-3rd Ave Zephyr ills FL Address . City state ContractoesTelephone No.: 813-782-5585 33542 6. Surety: Name Address city State Amount of Bond:S Telephone No,: e. Lender. Name Address city state Lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom nodoes or other documents may be served as provided by Section 713.13(1Xa)M,Florida Statutes: Name Address city Ft—ate Telephone Number or Designated Person: 8. In add bon to himself,the owner designates of to moolve's copy of the Uerioea Notics,as provided In Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9, Expiration date of Notice of Commencement(the expiration date may not be before the completion of oonstructIon and final payment to the contractor,but will be one year from the date of recording unless a different date Is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART Li SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE Zr o ED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND TO OBTAIN FINANCING,CONSULT 'H YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penally,of perjury,I declare that I have read the foregoing notice of commencement and the fads a therein am bus to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Sigh =!rher,orLesme.btOwnee�orL2�WsAVbodw P office , IParinsclMenaW Home Owner rinatorys TWOfflo ;6-;C) , t -.:T — The foregoing Inattrument was acknowledged before me thi a BY of W as (type of authortty,e.g.,oflicar,trustee,attorney In fact)for .{name adyon behalf of whom t exacutecD Personally Known C3 DR Produced Idenocallicin 0 ".619nature -VVx5zz Type ofidentification Produced Nam (Print) mu kc),L4 —10i. a-VNNotary public state of Florida Tina M Prater My Commission GG 211065 Expires 04125/2022 wpdatiroWnodcamnmenomment_poOS3048 State Of Florida,County Of Paloo This is to certify that the foregoing Is a true and correct copy of the document on file or of public record In this office. Witness my hand a o of I seal this cj?n Nikki Alvarez-Sowles,Esq.,Clerk&Comptroller o • IS 7 Pasco County, lo Ida - 0 0 OF Deputy Clerk