Loading...
HomeMy WebLinkAbout20-847 AL 0 Q �r o''"yiRtTn City of Zephyrhills "FIERMIMNSMSER a.` 5335 Eighth Street Zephyrhills, FL 33542 BNR-000847-2020 A Phone: (813)780-0020 %n Fax: (813)780-0021 Issue Date: 10/29/2020 Permit Type: Building New (Residential) 04 26 21 0120 00000 0480 6482 Bradford Woods Drive MM,9',*w"er nfo'croation Pe m tr'Information'� Contractor Information Name: PULTE HOME COMPANY LLC Permit Type:Building New(Residential) Contractor: PULTE HOME COMPANY Class of Work:SFR Construct LLC Address: 2662 Falkenburg S Rd Building Valuation:$114,122.00 RIVERVIEW,FL 33578 Electrical Valuation:$4,971.00 Phone: (813)964-5182 Mechanical Valuation:$4,402.00 /�� Plumbing Valuation:$5,147.00 ^ t Total Valuation:$128,642.00 Total Fees:$13,723.66 Amount Paid:$13,723.66 Date Paid:10/29/2020 8:56:50AM P oject De"scription CONSTRUCT SINGLE FAMILY 2,435 SQ FT-OAK PASCO Application Fees ' ,,, „_ ,, MW 3/4 Water Meter Fee(Calc) $473.78 Plumbing Plan Review Fee $32.87 Address Fee $30.00 Electrical Permit Fee $64.86 Mechanical Permit Fee $62.01 Mechanical Plan Review Fee $31.00 Plumbing Permit Fee $65.74 Building Permit Fee $600.61 Sewer Connection Residential Fee $2,090.00 Electrical Plan Review Fee $32.43 Building Plan Review Fee $300.30 School Impact Fee $8,328.00 Water Connection Residential Fee $1,010.00 Irrigation 3/4 Meter(Calc) $473.78 Driveway Fee $45.00 SIF 1 percent Fee $83.28 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. y1Q9L4—)L-F-rn CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Building Department )ate Received Phone Contact for Permitting owner's Name 1'Lj+C � Ofl1C L�l) )G{.Ilc (-LC, , Owner Phone Number Owner's Address 2U�r2 s' �a��-Gl��urL dl 0'd0 L Owner Phone Number Fee Simple Titleholder Name /r v Owner Phone Number Fee Simple Titleholder Address -1 J A JOB ADDRESS (,L'`l -/6 oI�U�-[:/`l p'- L/v If/C/!-uh Y �r�S I/ LO13�T f SUBDIVISION Ow�s D PARCEL ID# OqI (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT 0 SIGN Q DEMOLISH ® INSTALL 8 REPAIR PROPOSED USE ® SFR 0 COMM OTHER TYPE OF CONSTRUCTION J 1'BLLOJ7CK �n0 FRAME u STEEL = DESCRIPTION OF WORK GV vv n S BUILDING 512E SQ FOOTAGE � HEIGHT =BUILDING $f�jLr a /{r0 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ l /� 7 N� AMP SERVICE 0 PROGRESS ENERGY 0 W.R.E.C. PLUMBING $ I -7I190 �J =MECHANICAL l$ VALUATION OF MECHANICAL INSTALLATION 6J J6•�f� =GAS = ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS �{� ) FLOOD ZONE AREA =YES NO u/ t BUILDER COMPANY tIle /fv� ►L C. r]INLnG I LL SIGNATURE REGISTERED Y/ N__J FEE CURREN Y//N Address 5, 41 te t1bv I(lWmc)1 ` License# ELECTRICIAN COMPANY SIGNATURE Q/y REGISTERED Y/ N FEE CURREN Y!N Address l h l� /v, L License PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address 3133/►/�3� ��GJI�L6Gcr/uA�l�L378� License MECHANICAL COMPANY 9&4S & dyd/him14 SIGNATURE REGISTERED Y/ N FEE CURREN Y/N R/3 i7Gnt6Y7 f=hll� GtSLy?,FL 341 cp(�7 License# 3 Z� Address OTHER /ru COMPANY SIGNATURE p, REGISTERED Y/ N FEE CURREN Y/N r— Address / �r i � 3r License# Illlllf .11llllllllfllllllllllfllllllllll11111111IIIIIIIIIi1lI11111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. , Directions: Fill out application completely. Owner&Contractor sign back of application,notarized if over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW rr- Building Department Date Received Phone Contact for'Permitting ( k } lY G — ICE a`�1 9 BE # aaaaaaa F IL € a2a9 W a,a W,a a IE 2 Ouvner'.s Name r �� ' l Owner Phone Number) G-.. Owner's Address ' it J L Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS - I �G /��1�'� ,�L �J LOT#r SUBDIVISION —7 � PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR 8 ADD/ALT SIGN 0 0 DEMOLISH INSTALL REPAIR PROPOSED USE O SFR Q COMM �— OTHER D Z, TYPE OF CONSTRUCTION 0 BLOCK 0 FRAME STEEL DESCRIPTION OF WORK -G� �L /rYG J . ? 7 � �xlJ V i i j pI / 1I BUILDING SIZE SQ FOOTAGE 3 HEIGHT =BUILDING 1$ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL 1$ AMP SERVICE PROGRESS ENERGY 0 W.R.E.C. =PLUMBING $ [MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS 0 ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS 1 t FLOOD ZONE AREA =YES NO BUILDER COMPANY 1 6 SIGNATURE REGISTERED Y/N FEE CURREN Y!N Address I License# F_ ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address I License# PLUMBER � COMPANY L_ SIGNATURE REGISTERED Y/N FEE CURREN Address I License# F � MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# OTHER COMPANY V�/��t r ��rGI i C ✓l�`j d Y �� �i `tz' SIGNATURE REGISTERED Y/N FEE CURREN �Y/N/ F•'� Address (��,/ �� License# �(/� G .9998,1 1-11 9 11 9 1.119 1111 a 11999 a at It lvv.11gfe Iltagivallatallavillaaaffavl.I€ 11.lalVaNva1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W,Permit for new,construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.Ail commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign.back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Surrey/Footage) Driveways-Not over Counter if on public roadways..needs ROW Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licbnsing Section at 727-847-8009. Furthermore, if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If theproject does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes,zoning regulations,and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF.COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR RNEY BEFORE RECORDING X F COMMENCEMENT- FLORIDA JURAT(F.S. 117.03) tLl/ OWNER OR AGENT CONTRACTOR Su cri ad and swor to(or affirrri—ei b fore me this- Su scri and sworn to r a rrm foreme this , t �Gby �L v by 7 /�� (7TI�/i�L17CN�(Clic. Who is/are personally kn_pwn t=e or has/have produced Wh is/are personally to me or has/have produced as identification. as identification. . l I Pmaz,� Ai_/_Ji,/,&otary Public O Notary Public 011 Co sion No. Commis ' No. ��S �/7 N me o Notary typed,Orinted or stamped Name f Notary typed,printed cfr stamped pikTRICIA BURCHETT MY COMMISSION#GG365171 rnYPo PATRICIA BURCHETI" dc,.. j�(PIRES:AUG 13,2023 ?/���� My COMMISSION#GG365171 « Bonded through 1st State insurance EXPIRES:AUG 13,2023 " Bonded through 1st State Insurance D Single Family Dwelling Plan Review Comments 1. F.T.E.shall be a minimum of 8" above the road elevation and,an engineered site plan. 2: Lots shall.be graded to comply-with-R401.3.-of the F:B.C: I Compactiori test required if 2411 or more,of fill dirt is brought in at any one place. -4: Tie in survey required before pouring concrete. 5; .Driveways re ea R.O:W. use permit, All 4 sides of dn*vewaythru the sidewalk shall have expansion material., 6: All setbacks shall be met. 7: All property markers shall be uncovered,and marked at time of first 4nspecti6n. 8: All A.D..A.requirements shall be met:, 9: No electric,.plumbing;mechanical,or framing shall.be_covered without an inspection.and . approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): 11. Appliances.shall not be installed in a location where subject to mechanical.damage unless protected by:approved barriers: M303:4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C: 13. Foundation supports for A/C units shall be raised at least 3"above finished grade. M1308:1. 146 Return air in-all bedrooms. F.B.C. M1620:4 15. Smoke detectors.are to be installed in accordance with RM-.1 of the F.B.C_. 16:All glazing requirements are to be in accordance with R308A of the F.B.C; 17-All means.of egress are to be in accordance with RM I of the F.B.C.. 18: "Green gypsum board" shall not be used as a backer in showers or-tubs. R702:4.2 F.B.C. .. 19:.Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating or appliances or an attached garage.' They shall be installed in accordance.with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all. underground:plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced: 23. Tamper-Resistant Receptacles in accordance with 406.11 of the.201.6 ME:C 24. 19 accordance with the Land Development Code,lots-shall be sodded before final at least.lU feet around'the structure. 25. R403.5.3Hot.water:pipe.insulation Insulation for hot.water pipe'_with a minimum thermal resistance (R-value) of R-3 shall.be applied to the following:. Piping 314 inch (19:1.mm)and larger.in.nominal.diameter. Piping:serving more than one dwelling-unit: Piping located outside the conditioned space. Piping from the.water heater to a_distribution manifold:. Piping-located under a floor slab. Buried in piping,_ Supply and return piping in recirculation systems other than demand recirculation systems. 25.Blower'door-test shall be provided,before C.O. 26.A copy of the energy cacls shall be with permit at all times 27:Cone of final insulation-report shall be provided ivith permit before final . 28. No fence,pool onscreen enclosure Is issued with ihis permit. RRE:-Finished Floor Elevation FAC-Florida Building Code 6t'Edition R.O.W..-Right'of Way. A.D.A.-.Americans with Disabilities Act N.E.C.-National Electric Code(2016) s CITY OF ZEPHYRUILLS "City of Pure Neater" 5335 Eighth Street-Zephyrhills,Florida 33542-4312 (813)780-0000•Fax(813)780-0005 GENE WHITI~IELD.Mayor June 13,201$ CITY COUNCIL Mr.David Waronker 1420 Celebration Blvd., Suite 200 LANCE A.SMITH Celebration,FL 34747 Council President Dear Mr.Waronker, KENNM M.BURGESS,JR vice President City of Zephyrhills Ordinance 1003-08, Section 12, Paragraph 5, provides that planned unit developments (PUD) approved prior to September 30, 1988 are CHARLES E.PROCTOR exempt from paying transportation impact fees unless amended to permit additional development that would generate traffic. W.ALAN KNIGHT The Silver Oaks PUD was approved on its third and final reading on January 11, JODI WILKESON 1988, and therefore is exempt from paying transportation impact fees as stipulated in Ordinance 100308:provided the original permitted number of dwelling units remains the same. According to Todd Vande Berg, city planner,those numbers within the Silver Oaks PUD have remained constant. STEVEN F.SPINA City Manager Therefore,the Oaks at Pasco is exempt from paying these fees. A copy of Loxl L.xILLMAN Ordinance 1003-08 is provided for your information.The exemption and credits City Clerk,CMC section is located on page 10. MATTHEW E.MAGGARD Sincerely, City Attorney Steven F, Spina,PhD City Manager cc; Todd Vande Berg, City Planner Bill Burgess,Building Official , Matthew E.Maggard,City Attorney Building Department Date Received Phone Contact for Permitting a1111-aLail t .. . . . Owners Name �: %n (/U�` ' !G� Owner Phone Number Owner's Addressfy iv�� J. j Owner Phone Number 01 .Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS } �% ✓ /�i ' �II tl r� LOT# 1 SUBDIVISION �? ( PARCEL.ID# 'G�GF �. 't/r�!/"t�t�t/�tJ" t�`Tt/ JI (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT � SIGN 0 [� DEMOLISH e INSTALL 8 REPAIR PROPOSED USE SFR Q COMMA OTHER TYPE:OF CONSTRUCTION. O BLOCK y FRAME /�� STEE,L.G,f� :DESCRIPTION OF WORK fI✓r���/ llf'�� �����1 `&7 L 'GSI ./ti � } U BUILDING SIZE /XV�7 ! SQ FOOTAGE '1 HEIGHT �� BUILDING L_. VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING $ =MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS 0 ROOFING 0 SPECIALTY OTHER FINISHED FLOOR ELEVATIONS n ` I FLOOD ZONE AREA =YES NO BUILDER COMPANY d SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address License# F_7� MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address A License# OTHER COMPANY •1441f)Qt` SIGNATURE L REGISTERED Y/N FEE CURREN fY/N I ,( Address / ��( 7r License# j-l/ �1 ! 1 ! ! !.! ! [ [ ! !.! ! ii ! [ ! [ ! [ ! ! [ ! ! [ [ ! [ [ ! [ if.! ! ! t !! [:[ [ ! ! [ !.! ! ! ! 8 ! !9 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new:construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary.Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. * PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter"from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW --------------- 9D Fiby :t��� i i 45 i r 4 Tl��i�.. ,,147 _1 44 ( -0, i s 51 F=97.85I FF=91.7 l �FF=91.5 (FF�= i (FF,= FF=91.07s FF= 9.i.2 91.c _75- 7 4 ---._79, � 1� PASCO COUNTY, FLORIDA I Permit No. Date Permitted 0— r 'Builder Name/Owner Name G" Control W County Parcel No. bb r- —0 ,?. ubDiv: Address/Location ClassiflcatioNType of Usq TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: , Exempt n fifes -(] No How Determined Impact Fee Amount . 1 Zone No. TAZ: SCHOOL IMPACT FEE (( Account (656) Single-Family Detached House Amount $ _12,L 2A?_ (057) Mobl(e Home (058) Other.Residential 23) Collection fee Exempt M Yes . Q No How Determined PARKS AWRECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 7449, r' Exempt 0 Yes ��No How Determined'• LIBRARY"FEE ~ Land Accounf Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amount _ _. RESOURCE FEE ERU TOTAL AMOUNT Prepared By G Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE SEEN PAID AND RECEIPTED FOR 8Y A CENTRAI PEAMITTING OFFICE.OF PASCO COUNTY Acknowledgement below do not imply acceptance of concurrence,but simply receipt of a copy of this form,placing the bullding permit owner-on notice of hits assessment and the oondlttons of payment for some. DATE RECEIVED BY RECEIPT NO. DATE BY L-ni , 90 go 45 s �. 46j�,l, ' 1 47 s 4' _� 49 �} SCE; ! ! 5.1 F=91.85! FF=91.:7 =31. 6 FF;� :40 F =9 4.2 FF=9'1.t�7� i FF==91.0 -- PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 48, OAKS OF PASCO AS RECORDED IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 5,750 SO. FT. LIVING AREA = 1,662 SQ. FT. GARAGE = 549 SQ. FT. ENTRY = 25 SQ. FT. LANAI = 199 SQ. FT. PATIO = 0 SO. FT. DRIVEWAY = 328 SO. FT. A/C PAD = 9 SQ. FT. WALKWAY = 47 SQ. FT. IMPERVIOUS = 49% = 2819 SQ. FT. SOD = 2,931 SQ. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 400 SQ. FT. DRIVE APRON = 57 SQ. FT. o PUBLIC S/W = 250 SQ. FT. Z SOD = 93 SQ. FT. 1" = 30' TOTALS GRAPHIC SCALE AREA = 6,150 SQ. FT. DRIVEWAY = 385 SQ. FT. 0 15 30 SIDEWALK = 297 SQ. FT. SOD = 3,024 SQ. FT. r O FLOOD ZONE "AE" EL=88.5 � I � I APPROXIMATE DELINEATION LINE SCALED FROM FEMA MAP. 903g a.. � w ' 5 115.00' N85'42'16"E FLOOD ZONE "AE" O°-NB5'42'16"E cn EL=88.5 z 20.00' 34.5' m ♦----_ _ cn / — A/C co zZ Z 20.5' / 60.0' Z C ;L7 zA O 66.00' �I J O D mil :o r :•;`l; ;;,, _.' \ o m Ii.o, A m O yf J PROPOSED m o I 'lir." m CEDAR — CO1 'o ::1:;•:. .;1 0 4' GARAGE EXT. c A'I OD m D-1 D N 9.8, a FINISHED FLOOR 9 0, o 20.5 ' - 91.40 y µ' (,j'1 fTl ELEVATION= 6.0'' I O v Ss70 m =I N 1 CTI m\�� I FLOOD ZONE "X" ,D m "� v I� , CL { II \\ zz: — » 115.00' wl �Z 8950 S85 4216 W I J f, 1 O I fm 1 FLOOD ZONE "AE" yo EL=88.5 J PREPARED FOR: r "ie 0 BUILDING SETBACKS FRONT: 20' REAR: 10' SIDE: 5' SIDE STREET: 15' LEGEND: NOTES: — BUILDING SETBACK LINE PI POINT OF INTERSECTION NT OF CURVATURE I 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED —. CENTERLINE PC POPT POINT OF TANGENCY ON THE APPROVED ENGINEERING PLANS PREPARED — — — — RIGHT OF WAY LINE RP RADIUS POINT BY CORNELISON ENGINEERING & DESIGN INC. PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCP PERMANENT CONTROL POINT. ,. DATUM. TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (P) PER PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (C) CALCULATED A/C AIR CONDITIONER PS PLAT BOOK THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR PGS PAGES OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SO. FT. SQUARE FEET DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP - NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY DE DRAINARY SEWER GE EASEMENT EASEMENT THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP.NO. 12101CO289F SURVEYOR NOTES: DATED 09/26/2014 AND FOUND THE SUBJECT PROPERTY APPEARS TO UE 1. THE SURVEYOR HAS NOT ABSTRACTED THE PARTIALLY IN ZONE "X" & "AE". ZONE'X', AREAS DETERMINED TO BE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OUTSIDE THE 0.2%ANNUAL CHANCE FLOODPLAIN. ZONE"AE" AREAS DETERMINED TO BE SPECIAL FLOOD HAZARD AREAS SUBJECT YO OF WAY, RESTRICTIONS OF RECORD WHICH INUNDATION BY THE 1%ANNUAL CHANCE FLOOD EVENT, BASE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND. ELEVATIONS DETERMINED TO BE 88.5'. THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCAL F.E.M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF A5M 3. NOT VALID WITHOUT THE AUTHENTIC BRADFORD WOODS DRIVE BEING N0417'44-W, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A M E R I CA N SURVEYOR AND MAPPER. (FIELD DATE" S U F2\/E Y I N G '� 1" = 30 FEET �;;."r eo I Digitally signed by James 1=0.mlo, an SCALE: s••' ti'••� DN:-US,st=Fl"rida,I=Odando, 8c MAPPING INC. � �..e.< o=AMERICANSUflVEYING&MAPPING, e c APPROVED 8Y: JB g ' _INC,c-James W B"leman, CERTIFICATION OF AUTHORIZATION NUMBER LB 6393 �� mow'• email=holeman@asmcor orate.com a:,:.n„°o`:aU:':e �-1 P FOR 3191 MAGUIRE BOULEVARD, SUITE 200 .•3� �Date.2070.09.0911:33:4b-04'00' 191105 LOT 48 ° ,::�:• Adobe Acrobat THE JOB No. ORLANDO, FLORIDA 32803 FIRM (407) 426-7979 DRAWN BY: DSB PLOT PLAN 09 03 2020 JG WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE INVOICE1111 • ' CITY OF BILLING CONTACT 1 JODY SALTER i PULTE HOME COMPANY LLC 2662 FALKENBURG S RD RIVERVIEW, FL 33578 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00001735 10/28/2020 10/28/2020 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-000846-2020 3/4 Water Meter Fee(Calc) $473.78 Address Fee I $30.00 Building Permit Fee j $628.74 Building Plan Review Fee I $314.37 Driveway Fee $45.00 Electrical Permit Fee l $67.46 Electrical Plan Review Fee $33.73 Irrigation 3/4 Meter(Calc) $473.78 Mechanical Permit Fee $65.73 Mechanical Plan Review Fee $32.86 Plumbing Permit Fee 'I $65.74 Plumbing Plan Review Fee $32.87 School Impact Fee I $8,328.00 Sewer Connection Residential Fee'. $2,090.00 SIF 1 percent Fee ; $83.28 Water Connection Residential Fee $1,010.00 6470 Bradford Woods Drive Zephyrhills, FLORIDA 33542 SUB TOTAL $13,775.34 I REMITTANCE INFORMATION �i TOTAL $13,775.34 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 . I i �I I li I 'I i October 28,2020 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 I so P-728 � 44 f i 4 T j' 41Y4 �'�i fti .Asx--C _i 49 i. aOt7 I F=9:1:85 1 IFF=9-1.851 ZFF-g1.7 , �: ,� iFF-9� 4� OFF=9i.2 071 _ t r � 85 City of Zephyrhilis PERMIT NUMBER �i 5335 Eighth Street Zephyrhills, FL 33542 BNR-000847-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 10/29/2020 Permit Type: Building New (Residential) _# Poperty�N'umber� "" c � x. �. �* < 4 - " Street Address 04 26 21 0120 00000 0480 6482 Bradford Woods Drive ' ` ; OwneInfo matio -£ � '' Permit_>Infor ation"` ' " " Contra tcoInformation Name: PULTE HOME COMPANY LLC Permit Type:Building New(Residential) Contractor: PULTE HOME COMPANY Class of Work:SFR Construct LLC Address: 2662 Falkenburg S Rd Building Valuation:$114,122.00 RIVERVIEW,FL 33578 Electrical Valuation:$4,971.00 Phone: (813)964-5182 Mechanical Valuation:$4,402.00 Plumbing Valuation:$5,147.00 /t r Total Valuation:$128,642.00 Total Fees:$13,723.66 Amount Paid:$13,723.66 Date Paid:10/29/2020 8:56:50AM NroeC�t��@rS,r.p _ �,�,,,.�t �.. a�°>"�ss«i.''" ;`.ta&^3:� _ °? '.sue"" "�w, rm� s, r��xt�� w•re_ . CONSTRUCT SINGLE FAMILY 2,435 SQ FT-OAK PASCO ,.�t -"'�K+t r- A IicatronFees. 3/4 Water Meter Fee(Cale) $473.78 Plumbing Plan Review Fee $32.87 Address Fee $30.00 Electrical Permit Fee $64.86 Mechanical Permit Fee $62.01 Mechanical Plan Review Fee $31.00 Plumbing Permit Fee $65.74 Building Permit Fee $600.61 Sewer Connection Residential Fee $2,090.00 Electrical Plan Review Fee $32.43 Building Plan Review Fee $300.30 School Impact Fee $8,328.00 Water Connection Residential Fee $1,010.00 Irrigation 3/4 Meter(Cale) $473.78 Driveway Fee $45.00 SIF 1 percent Fee $83.28 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. c 01 10 jk yjQgq�r2ypr. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER c.WN,iyl z"Flo i ct 1 i nt nNNm.auvi, Building Department )ate Received I_�"-Ir _ Phone Contact for Permitting_ ��(� (, 3� -rx-r-ra )wner's Name Per l�C ( p�l C G' r 1 1 ow =Owner Phone Number �'�._ owner's Address 2(.t(i-� S. �Q.��(i�(,l�-�' ,�i itj�f t- , ___ -ee Simple Titleholder Name �— /A � Owner Phone Number Owner phone Number Fee simple Titleholder Address 1� JOB ADDRESS ( � 'W •y D�,�� ( S E' 3� SUBDIVISION p �1 O LOT# ' = PARCEL lD# WORK PROPOSED NEW (OBTAINED FROM PROPERTY TAX ArOTnCE1 INSTALL STR 0 RREPAIR SIGN PROPOSED USE � SFR � DEMOLISH TYPE OF GONSTRUCI ION 0 STEEL COMM 0 OTHER BLOCK 0 FRAME 0 DESCRIPTION OF WORK Bull_DiNG SiZE J' 1mmit SQ FOOTAGE HEIGHT ter. L BUILDING $ =ELEGTRlCAL VALUATION OF TOTAL CONSTRUCTION R �ql ot_ AMP SERVICE - r =PLUMBING "MECHANICAL $ � /}� VALUATION OF MECHANICAL INSTALLATION 1 !.d =GAS ROOFING 0 SPECIALTY OTHER FINISHED FLOOR ELEVATIONS /�J j Jl y/ FLOOD ZONE AREA ]YES NO BUILDER COMPANY SIGNATURE ,f REGISTERED Y/ N FEE CURREN Y//N_ Address �� �, � ll��tfrC' tV��vf��l.)i��,3� License# Itf' ©1 ELECTRICIAN 1 COMPANYL� SIGNATURE /�/y REGISTERED Y/ N FEE CURREN Y I N Address !�G 67� / L "License# 3CO'-;-5-7 �J PLUMBERE AV COMPANY V/' r lr3 1 D M SIGNATURE REGISTERED Y/ N FEE CURREN C Y I N Address 3133 fV jIJ,ldG j L,3j�7i`�rJ License# 1 O FC/W�7*_1 MECHANICAL COMPANY cn�s yT1Y CLt GG/l1�I/lvrw * SIGNATURE REGISTERED YIN I FEE CURREN Y/N J3faGn Address �hlf� GYSzart, (, 3 Go(p7 License# t d,4/1 tI !'�32 OTHER COMPANY / ��✓t �� SIGNATURE REGISTERED Y i N FEE CURREN Y I N Address /193il6mn /G,f? , � 3 License# I IIIBIIIII11111111 full 1111111111I11111tlliliiiliiilliililllilllliiili RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects 'COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.Alt commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "*"PROPERTY SURVEY required for all NEW construction. , Directions:.... Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) RerODfs if shingles Sewers Service Upgrades A/C Fences(PlofitSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Lic$nsing Section at 727-847-8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that:Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.,If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water_/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more, I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas, or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF.COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER ORA— TORNEY BEFQRE RECORDING Y FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR ��Su scri ed and swor to(or affifine b fore me this Su scri and sworn to r affirm foreme this by �� f� by Who is/are personally known tome or has/have produced Wh is/are personally own to me or has/have produced as identification. as identification. Zv otary Public i O Notary Public Co ` 7;1 n No. C"�C� ( �17� Commis a f ` ` E N me of Notary typed,Orinted or stamped Name 6f Notary typed,printed dr stamped 7through 'iE ,� PATRICIA BURCHETr GG365171 d`' °yMY COMWiISSION#GG365171 a 2023 EXPIRES:AUG 13,2023 tate Insurance Bonded through Ist State Insurance m. 4 ' . Single Family' Dwelling Plan Review Comments 1. F:RE shall-be a minimum of 8" above the road elevation and an engineered site.plan. 2: Lots shall be graded to.comply with R401.3 of the F.B.C.. . .3. Compaction test required if 24 or more.of fill dirt is brought in at any one.place. 4: Tie in survey required before pouring concrete. 5- Driveways re -ire .a R.O.W. use permit, All 4 sides of driveway thru the sidewalk shall have -expansion material.: 6: All setbacks shall be met. 7:. All pro ert markers shall be uncovered,and marked at time:of first inspection. - p p ..y 8:. All A:D:.A.requirements shall be met: 9: .No electric,.plumbing;mechanical, or framing shall be:covered without an inspection.and . approval first. 10:.All Garages shall comply with section R302.6 of the F.B:C. (Fire Separation).: 11. Appliances shall.not be-installed in a location.where subject to mechanical damage unless protected by approved barriers. M303:4 of the F.B.0 12. Water heaters.shall comply with section P607.3 ofthe F.B:C. 13: Foundation supports for A/C units:shall be raised at least 3"above finished grade. M1308:1 14. Return air ui all bedrooms. F.B.-C. 'M1620:4 15. Smoke detectors.are to be installed in accordance with R313.1.of.the' F.B.C. 16.All glazing requirer'ents are to be.in.accordance:with R308.4 of the F.B.C: 17. All means.of egress are to be in accordance:with RM I of the F.B.C.. 18. .'Green gypsum board" shall not.be used as a backer in showers,or-tubs. R702.4.2 EB.C. 19:.Com'bination-type AM breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monOide.alarms will.be required in new construction that-uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C: 21. All plumbing,mechanical, and electrical shall�be separate from unit to unit.. This includes all: .. . underground plumbing and electric. 22. All 201-6 N.-E.C. Codes will be enforced: 23. Tamper- Resistant Receptacles in accordance with 406.11 of the,20161 N.E.0 24. In accordance with the Land Development Code,lots shall be sodded before final at least.10 -feet around the structure: 25-. R403.5.3Hot-water.pipe insulation Insulation for hotwater pipe with a minimum thermal resistance (R-value) of R-3.shall be applied to the following: Piping.31,inch (19:1 mm) and larger in.:nomina.l diameter._ Piping serving more than one dwelling unit. Piping located outside the conditioned space.. Piping from the:waterheater to a distribution manifold. Piping located under.a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25.Blower.door test shall be provided.before C.O: 26.A copy of the enemy cacls shall be with permit at all times 27. Copy of final insulation-report shall,be provided with permit before finab . 28. No fence,-pool or screen enclosure :is issued with this permit. F.F.E.-Finished Floor Elevation- F.B.G.Florida Building Code 6 h Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) Building Department Date Received Phone Contact for Permitting { } aI21aaa9a Owner's Name f n / f n �/t/��' •!d� Owner Phone Number Owner's Address !v1 L Owner Phone Number .Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address }� �i1 JOB ADDRESS ^- r� G l. �i f I�I� �� �J LOT# SUBDIVISION / . � � PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED R NEW COLSTR H' REPAIR SIGN [� DEMOLISH INSPROPOSED USE SFR 0 COMM 4. i� OTHER T� TYPE:OF CONSTRUCTION )B,LLOCCKK. 0 FRAME /� STEEL 'DESCRIPTION OF WORK ��!`✓' G �� �j� Z ' "�/ "GGI Y U BUILDING SIZE 1 �/' / SQ FOOTAGE HEIGHT BUILDING VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY Q W.R.E.C. =PLUMBiNG 1$y =MECHANICAL [� VALUATION OF MECHANICAL INSTALLATION =GAS Q ROOFING 0 SPECIALTY OTHER FINISHED FLOOR-ELEVATIONS ` 7 FLOOD ZONE AREA DYES NO BUILDER COMPANY ,I SIGNATURE REGISTERED Y/N FEE CURREN Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# OTHER COMPANY ��� I�j��%/ ✓l��/1 D�' /G�iy����1`u/� SIGNATURE REGISTERED Y/N FEE CURREN^ �Y/N Address V�/ h \ License# 7�j�(/� &A @IV211.911 aria 9.889991991 $ @@ €IIC1Rag I; alogIgativiaS 18851a1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten.(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new.construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit-for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. 'PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW : 'RASCO COUNTY, FLORIDA t t Permit No. Date Permitted ZOY Builder Name/Owner Name Control#' " County Parcel No. -Q 70- ,0. ubDiv: Address/Location • ,52 Classification/Type of Usg TRANSPORTATION IMPACT FEE Rate: SQ.Ft Unit: _ Exempt n Yes -[] No How Determined Impact Fee Amount Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other.Residential 123) Collection fee Exempt (�Yes - Q'No How Determined PARKS AND,RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ is Exempt ❑Yes [:]No How Determined' LIBRARY'FEE Land Accounf Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By t' Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOt.INTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PER MITTiNO OFFICE•OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply reoelpt of•a copy of this form,placing Chi bullding permit ownsFon notice of ttils assassment and the condlUons of payment for same. DATE• RECEIVED BY RECEIPT NO. DATE BY PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 48, OAKS OF PASCO AS RECORDED IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ON LOT CALCULATIONS LOT = 5,750 SQ. FT. LIVING AREA = 1,662 SQ. FT. GARAGE = 549 SQ. FT. ENTRY = 25 SQ. FT. LANAI = 199 SQ. FT. PATIO = 0 SQ. FT. DRIVEWAY = 328 SQ. FT. A/C PAD = 9 SQ. FT. WALKWAY = 47 SQ. FT. IMPERVIOUS = 49% = 2819 SQ. FT. SOD = 2,931 SQ. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 400 SQ. FT. DRIVE APRON = 57 SO. FT. o PUBLIC S/W = 250 SO. FT. z SOD = 93 SQ. FT. 1" = 30' TOTALS ' GRAPHIC SCALE AREA = 6.150 SQ. FT. 0 15 30 DRIVEWAY = 385 SQ. FT. SIDEWALK = 297 SQ. FT. SOD = 3,024 SQ. FT. r O FLOOD ZONE "AE" EL=88.5 -Q I � I APPROXIMATE DELINEATION LINE SCALED FROM FEMA MAP. 90 ,3B Bg 66 115.00 FLOOD ZONE "AE" I� $9' N85"42'16"E N (n EL=88.5 N8 20-0 6"E o �5' O m 20.00' _ I----_ P' � A/C 4S. o A :. O 66.00' o I J O Am t7 'TI rn: ...,� I:..O1; .il mZo 0 I—i -Q rn O y� .: J o ? PROPOSED r^D r '1 :,.'. m CEDAR — C01 'o Frl D 0p •I 9 8' 4' GARAGE EXT. 0 No 20.5 FINISHED FLOOR 9 0' a FF frl o ELEVATION=91.40' ,�6.0'' i I p �-1p IN I _ m,• O o Dm. .v O 3>0 4 I m I ? FLOOD ZONE X. 4 O 49.0' •��'15.0: 28.5' � p O o D 22. — — ' 115.00' wl �Z a9so S85'42'16"W � q r O oZ m I FLOOD ZONE "AE" EL=88.5 .� PREPARED FOR: I <01 �' r_ _ ite n BUILDING SETBACKS FRONT: 20' REAR: 10' SIDE: 5' SIDE STREET: 15' LEGEND: NOTES: — BUILDING SETBACK LINE PI POINT OF INTERSECTION POINT OF CURVATURE 1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED —.— CENTERLINE PC POPT POINT OF TANGENCY ON THE APPROVED ENGINEERING PLANS PREPARED - — — RIGHT OF WAY LINE RP RADIUS POINT BY CORNELISON ENGINEERING & DESIGN INC. PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCP PERMANENT CONTROL POINT DATUM. TYP TYPICAL � PROPOSED DRAINAGE FLOW CS CONCRETE SLAB (p) PER PLAT (0) THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (C PLAT BOOK THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PAGES OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SQ. FT. SQUARE FEET DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM SANITY SER THIS IS NOT A SURVEY DEE DRAINAGE EASEMENTSEMENT THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO289F SURVEYOR NOTES: DATED 09/26/2014 AND FOUND THE SUBJECT PROPERTY APPEARS TO UE 1. THE SURVEYOR HAS NOT ABSTRACTED THE PARTIALLY IN ZONE "X" & "AE". ZONE "X", AREAS DETERMINED TO BE LAND SHOWN HEREON FOR EASEMENTS, RIGHT OUTSIDE E EIRMINEDETO BE SPECIAL FLOOD HAZARDPAREASZSUBJECT,TOREAS OF WAY, RESTRICTIONS OF RECORD WHICH INUNDATION BY THE 1%ANNUAL CHANCE FLOOD EVENT, BASE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND. ELEVATIONS DETERMINED TO BE 88.5'. THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCAL F.E.M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF 3. NOT VALID WITHOUT THE AUTHENTIC BRADFORD WOODS DRIVE BEING N0417'4eW, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A M E R I CA N SURVEYOR AND MAPPER. A5TA (FIELD DATE:) S U FRS/I-Y I N G 1" = 30 FEET a1�;;Mr a"'�f Digitally signed by James Boleman SCALE: s3's;•�,.rr"• % DN:c=US,st=Florida,l=Orlando, JB Sc MAPPING INC. E �_� tl^• =AMERICAN SURVEYING&MAPPING, APPROVED BY: 1 INC,cn=JamesW Boleman, CERTIFICATION OF AUTHORIZATION NUMBER L13#6393 sntenr je email=jboleman@asmcorpomlecom FOR 191105 LOT 48 3191 MAGUIRE BOULEVARD, SUITE 200 ,,;�. ;"a.:,,a '-Date:2020.09,0911:33;4fi-04'00' THE JOB NO. ORLANDO, FLORIDA 32803 �a ` Adobe Acrobat version:11.0.23 FIRM °�mlmia (407) 426-7979 DRAWN BY: DSB PLOT PLAN 09 03 2020 JG WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE