Loading...
HomeMy WebLinkAbout20-883 � y - Q City of Zephyrhills PERMIT NUMBER 5335 Eighth Street ' Zephyrhills, FL 33542 ELCMISC-000883-2020 Phone: (813)780-0020 j Fax: (813)780-0021 Issue Date: 10/23/2020 Permit Type: Electric Service ReplacemenVMisc PropelrtyNumber v..� Street Address 32 25 21 0100 01800 0130 7091 Boxer Round PI Owner Information Permit Information Contractor Information Name: YADILKA&ALBINO SANTIAGO Permit Type:Electric Service ReplacemenUM Contractor:VIVINT SOLAR DEVELOPEF SANTIAGO Class of Work:Add/Alter Residential LLC Address: 7091 Boxer Round PI Building Valuation:$3,146.00 ZEPHYRHILLS,FL 33541 Electrical Valuation:$12,584.00 Phone: Mechanical Valuation: Plumbing Valuation: �} Total Valuation:$15,730.00 Total Fees:$237.97 (� Amount Paid:$237.97 Date Paid:10/23/2020 11:24:03AM dJ Project t)escrI U n INSTALLATION ROOF MOUNT PV SOLAR SYSTEM Application Fees Electrical Plan Review Fee $51.46 Building Valuation Fee $27.86 Electrical Permit Fee $102.92 Building Permit Fee $55.73 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. -�v M CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INSTR#2020171 1 2O OR BK 10195 PG 2437 Page 1 of 1 10/13/2020 10:20 AM Rcpt:2214615 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez Sowles,Esq.,Pasco County Clerk&Comptroller Permit No. Parcel ID Na 3 Z-ZS-2 1-01 00. 0 ►8 0 o- 0 r3 0 . NOTICE OF COMMENCEMENT steteof Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvementwill be madeto certain real property,and in a=rdance with Chapter 713,Florida Statutes, the following information's provided in this Node of Commencement 1. Description of Property. Penccel deadfication No. �! �Street Address: �.o b0 k'r 1%� F un A P L . 2. General Description of Improvement Installation of a roof-mounted solar photovoltaic system LLl LU Z U -i W U3LU LL- Cn d 3. Owner Information or Lessee information I the Lessee contracted for the impmvement (:l O '_ H 7491 4YO-tt focm PL y NOS L a��� � � o Address city state Lr LrJ _z .-.1 Interest in Property: O Q or Qt- E- O Name of Fee Simple Titleholder. A.E3 A- I U � (If different from Owner listed above) M = O C) Icy. _i � t >' WO U 4. Contr,�r Uivint Solar Developer,LLC city 0 R io0 o vS Name 0 � Q J Hanna 5100 W Ave Tampa J Address City State (.) CO Q LL t Contractors Telephone No.: (813)359-0634 tJ -5 Z O O g E- tea ¢ } cn 5. Surety: Name JI O O }. !❑ IL U U 5 < Address City State V. 0 O O Amount of Bond:S Telephone No.: �q U7 Q _J W Q 8. Lender. (n LLI LL z Y Name Address city State F-- F— O Z rY) Lenders Telephone No.: 7. Persons within the State of Florida designated by the awner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)('7),Florida-Statutes: Name Address City Stale i hr Telephone Number at Designated Person: 11 In addition to himself,the owner designates of to receive a copy of the Lienors Notice as provided in Section 713.13(1)(b),Florida Stahrteg• % Telephone Number of Person or Entrty Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment >;:ti.•YX� R 11 contractor,but will be one year from the date of recording unless a different date is specified): P TL 20 •' '_�;Q C o WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCBvi ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND •;� :ja' �•; o l!r RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSU v V41TH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. ,•..�Cr Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the fads stated therein are true to the best i _ - �� of my knowledge and belief. STATE OF FLORIDA 'K COUNTY OF PASCO lll//N��___ S' nature of Owner or Lessee,or Owners or Lkidsieds Authorized car/Di rlPartnq LkA jgear ^^'' Signatory's Title/OMce de .1 2QDb y f►The foregoing Instrument was acknowledged before mellthnnis y y v as W n (type of authority,e.g.,officer,trustee,aftamay in fact)for O CJ (name of pa n beha omi ecuted). Personally Known❑OR Produced'identdieation Notary Signature .y Type of IdenbFrwtion Produce O L Name(Pdr>h ftrn 8 SSW Florida E MY Comrnit9ion GG 9E3833j wpdatalbeslnctc=mmeneement_pe053048 orNr ExP�inf01/20Y4 813-780-0020 City of Zephyrhills Permit Application Fax-8113-780-0021 Building Department Date Received Phone Contact for Permitting F -FT-� . . . . . . . Owner's Name A ri,t,V,A S A N Tr 460 Owner Phone Number Owriees Address 1 709/ flOtF-R ROUA]b�ft- Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS [ 70 t?J Pt.. Zf:P14LJJQNCUL-_S _J LOT# SUBDIVISION PARCELIO#1' (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR R ADD/ALT SIGN DEMOLISH R INSTALL REPAIR PROPOSED USE 0 SFR Q COMM Q OTHER TYPE OF CONSTRUCTION Q BLOCK FRAME Q STEEL DESCRIPTION OF WORK InglaWltp t7F A PV &OLAR PA BUILDING SIZE SO FOOTAGE HEIGHT I . . . . . . . . . . . . . . . . . . . . . . . . . . . . BUILDING VALUATION OF TOTAL CONSTRUCTION DELECTRICAL AMP SERVICE Q PROGRESS ENERGY Q w.mF-c. =pLumEiNG Is F-1MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS Q ROOFING = SPECIALTY F-1 OTHER 01 FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO . ... . . . . . . . . . . . . .111 . . . . . . . . . . . . . . . . . 6 . . . . BUILDER COMPANY 1 91-VITA IT(06 L 4 bPVr-,"FrA SIGNATURE REGISTERED YIN I FEE CURREN f YIN Address W- U061AAAK MMI'A Ucense# ELECTRIC II COMPANY FJL 1A P �,FAI-FWPLEKI SIGNAT ; REGISTERED I YIN I FEE CURREN I- Y/N I Address—I'sx-p-r-y-ly-w-Ard P'Vejnum I License I Prr?0m. PLUMBER COMPANY = SIGNATURE REGISTERED Y1 N I FEE CURREN Address I License ffi F- MECHANICAL I COMPANY = SIGNATURE REGISTERED I Y/ N I FEE cuRRFN L_yl N Address I License 4 OTHER COMPANY = SIGNATURE- REGISTERED Y/N I FEE CURREN Address License# lltltllttttttllllltllltliltltlttltltttttltltitlltttitlttlttltlttltl RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum tan(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&I dumpster Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(110)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence Installed, Sanitary Facilities&I clumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dim Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Remofs if shingles Sewers Service Upgrades A/C Fences(PlatiSurvey/Footage) Urtvaways-Not over Counter if on public madways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed-restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",1 certify that 1 have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads,Wetland Areas and Environmentally Sensitive Lands,Water/WastewaterTreatment - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Carps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the.use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone"A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing,signs,wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY,BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F. 1 .03) OWNER OR AGEN CONTRACTOR �}tp nd s r ff efo a this Subscribed and swam to(or affirmed)before me this VU_6'�bY by Wh i re aen otpto me or haslFiave pro Who is/are personally known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,pffnted or stamped Name of Notary typed,printed or stamped �.� Notary Putabc Stele of Flonda James Quillen My Com...ms HH 012750 4415Expires M25/2024 v; i 1800 W Ashton Blvd. -~ - � _�''- ; Lehi, LIT 84043 Structural Group J. Matthew Walsh, PE Kirk M. Nelson, SE Samuel Brown, PE- Civil Director of Engineering Structural Engineering Structural Engineering james.walsh@vivintsolar.com kirk.nelson@vivintsolar.com sam.brown@vivintsolar.com October 06, 2020 Re: Structural Engineering Services Santiago Structure 7091 Boxer Round PI, Zephyrhills, FL S-6447858; FL-01 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced structure: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Structure: The existing structure has typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Southern Pine#2 or better with standard construction components. The designed areas of the home consist of the following framing methods: • Roof Sections: Prefabricated trusses at 24" on center. Survey photos indicate that there was free access to verify the framing size and spacing. B. Loading Criteria 14.66 PSF= Dead Load (roofing/framing) 3.00 PSF= Dead Load (solar panels/mounting hardware) 17.66 PSF=Total Dead Load 20 PSF= Roof Live Load (based on local requirements) Wind speed of 145 mph (based on Exposure Category D-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C. Solar Panel Anchorage 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. • SnapNrack Installation Manual, which can be found on the SnapNrack website(https://snapnrack.com/). 2. The solar panels are 1'/z" thick. At no time will the panels be mounted higher than 10" above the existing surface of the roof. Page 1 of 2 v1 v'nt - 3. The following mounting types shall be used. Please refer to the mounting details for the associated mounting method requirements. Based on our evaluation, the uplift demand is less than the maximum allowable per mount and therefore is adequate. • RL-U SpeedSeal: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) of timber construction specifications for Southern Pine is 235 Ibs/inch penetration. 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2017 FBC 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10. These spacing requirements apply to all mount types indicated above. The following values have been verified by in-house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections should be staggered, where possible, to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 48 48 48 48 48 48 Cantilever in 16 16 16 12 12 12 D. Summary Based on the above evaluation, with appropriate panel anchors being utilized, the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida Building Code-Residential 6th Edition, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. Regards, J. Matthew Walsh, PE FL License No. 84923 _ * No,84., a STATE OF ";�W / iP ORlO, � �S ONAl. /l111 Mk \ 10/06/2020 Page 2 of 2 '1/11/11' t. . -1 1 'i vi t ; f 1800 W Ashton Blvd. i � �.- � �.i Lehi, 11T 84043 Structural Group I Matthew Walsh, PE Kirk M:Nelson, SE Samuel Brown, PE-Civil Director of Engineering Structural Engineering Structural Engineering fames.walsh@vivintsolar.com kirk nelson@vivinrsolar.com sam.brown@vivintsolancom Structural Design Criteria Project Address Date: October 6,2020 Santiago Residence 7091 Boxer Round PI Zephyrhills,FL 5-6447858 \\\\\P.�'(IAE 4V`-� �//,i Residence M SF l< Risk Category II S Roof Area 2861 sf * NcJ Z4� Upper Floor Area0 sff/I — Number of Stories 1 STATE OF Mean Roof height 15 ft Upper Floor height 0 ftOR1OP-'�G�� \ Location Parameters �ONAL Latitude 28.261389 1/d/�UR(gQl\��� Longitude -82.226111 Site Class D(Default) Risk Category II Existing Gravity Parameters Roof Dead Load 5 psf Composite Shingle 2 psf 3/4"Plywood Sheathing 2 psf Roof Framing @ 24 in.o.c. 3 psf Ceiling,Mechanical,Electrical 2 psf Miscellaneous 15 psf TOTAL Roof Live Load 20 psf Wall Dead Load Ground Snow Load 0 psf 8 ft Wall Height Flat Roof Snow Load 0 psf 300 ft Wall Length 12 psf Wall Weight New Gravity Parameters Roof Dead Load 3.00 psf Solar Panel Weight Roof Live Load with Solar Panels 0 psf Roof Slope Factor 0.7 Roof Slope Factor(ASCE 7-10 Fig.7-2b) Roof Snow Load 0 psf ASCE 7-10 Eq.7.4-1 Seismic Parameters SS= 0.067 g 0.2 sec Spectral Response Acceleration S1 = 0.034 g 1.0 sec Spectral Response Acceleration Fa= 1.600 g Site Coefficient from ASCE 7-10,Table 11.4-1 Fv= 2.400 Site Coefficient from ASCE 7-10,Table 11.4-2 SDS= 0.071 g Short Period Design Spectral Acceleration SD1 = 0.054 g 1 Second Period Design Spectral Acceleration Page 1 of 4 vivint, Wind Parameters Wind Speed 145 mph Exposure Category D Roof Angle, 0 27.0 deg Product Information No.of Panels 22 Weight 3.00 psf including mounting system Installed Area 399.3 ft2 No.of Connectors 29 Total Existing Roof Load=Roof Dead Load+(Roof Live Load or Snow)x Spacing 69.32 plf Total New Roof Load=Roof Dead Load+Added Dead Load+(Roof Live Load or Snow)x Spacing) 35.32 plf Change in Demand=(Total New Load-Existing Load)/Existing Load -49.05% Total New Gravity Loads are less than Existing Loads. OK 2015 IEBC Section 707.2 states: "Where addition or replacement of roofing or replacement of equipment results in additional dead loads,structural components supporting such reroofing or equipment shall comply with the gravity load requirements of the International Building Code. EXCEPTION 1. Structural elements where the additional dead load from the roofing or equipment does not increase the force in the element by more than 5 percent." 2015 IRC Section AJ501.4 states: "The minimum design loads for the structure shall be the loads applicable at the time the building was constructed,provided that a dangerous condition is not created. Structural elements that are uncovered during the course of the alteration and that are found to be unsound or dangerous shall be made to comply with the applicable requirements of this code." 2017 FBC Section AJ104.1 states: "Detached one-or two-family dwellings that are not irregular buildings under Section R301.2.2.2.5 and are not undergoing an extensive reconstruction shall not be required to be evaluated." Page 2 of 4 ® i i v1vit `�� 1800 W Ashton Blvd_ -s�'l ' Ecf,, Lehi, UT 84043 Structural Group J. Matthew Walsh,PE Kirk M.Nelson, SE Samuel Brown,PE-Civil Diredor of Engineering Structural Engineering Structural Engineering james.walsh@vivinrsolar com kirk.nelson@vivintsolar.com sam.brown@vjWnisolar.com Mount Spacing Calculation ASCE 7-10 Simplified Procedure for Components and Cladding NDS Section 12 [CC Code Cycle 2015 Wind speed (V) 145 mph Exposure Category D Roof Slope (0) 27.0 deg Effective Wind Area 20 sf Least Horizontal Dimension 0.00 ft Adjustment Factor(lt) 1.47 Topographic (Kt ) 1 Panel Dead Load TO 3 psf Ground Snow Load 0 psf Flat Roof Snow Load (pf) 0 psf ASCE 7-10 Eq. 7.3-1 Slope Factor(Cs) 0.72 ASCE 7-10 Fig. 7-2b Panel Snow Load 0 psf Pfcs Total Dead Load (D) 3 psf Panel Dead Load + Roof Snow Load Portrait Landscape Vertical Spacing (L) 67 in 39 in Based on length of the panel Wind Pressure Zone 1 Zone 2 Zone 3 Lookup Pressure (Pnet30) 31 psf 49 psf 89 psf ASCE 7-10 Fig. 30.5-1 Uplift Pressure W 46 psf 72 psf 131 psf A*Kzt*Pnet30 Fastener Type 5/16 Yield E uations NDS Table 12.3.1A Diameter 5/16 in I m 648 Ibs Fasteners 1 1 s 1222lbs Embedment (Dpen) 2 1/2 in II 359 Ibs Load Duration (Cd) 1.6 III m 372 Ibs Pullout per Inch (W) 235 lb/in III s 389 Ibs IV 336 Ibs Uplift Capacity 939 Ibs DpenCdW Shear Capacity 336 Ibs Based on equations from NDS 12.3.1A Page 3 of 4 'v'nt, 1 1800 W Ashton Blvd. - • �;'* � •� 'I J Lehi, UT 94043 Structural Group J.Mafthew Walsh,PE Kirk M. Nelson,SE Samuel Brown,PE-Civil Director of Engineering Structure!Engineering Structural Engineering james.walsh@vivinrsolar com kirk.nelson a@vivinisolar com sam.brown@vjWntsolar.com Mount Types: Uplift Shear Fasteners (Capacities based on manufacturer testing) RL-U S eedSeal 443 Ibs 238 Ibs 1 Fastener Capacity 939 Ibs 336 Ibs Controlling Capacity 443Ibs 238lbs Portrait Zone 1 Zone 2 Zone 3 Uplift 37 in 35 in 37 in Shear 376 in 566 in 1132 in Capacity Manufacturer or AHJ 48 in 48 in 48 in L*SIN(6)*D Controlling Spacing 37 in 35 in 37 in Landscape Zone 1 Zone 2 Zone 3 Capacity Uplift 63 in 59 in 64 in L*0.6(D-W) Shear 645 in 970 in 1940 in Capacity Manufacturer or AHJ 48 in 48 in 48 in L*SIN(A)'tD Controlling Spacing j 48 in j 48 in j 48 in Tributary Area (Atrib) Zone 1 Zone 2 Zone 3 Mount Spacing *Vertical Spacing Portrait 17 sf 11 sf 6 sf Landscape 13 sf 9 sf 4 sf Demand in Uplift Atr;b*0.6(Pd-W) Portrait 443Ibs 443Ibs 443Ibs Landscape 338lbs 359lbs 333lbs Capacity in Uplift 443 Ibs 443 Ibs 443 Ibs Max Utilization=1.00 Demand in Shear Arab*SIN(6)*D Portrait 23lbs 15lbs 8lbs Landscape 18lbs 12lbs 6lbs Capacity in Shear 238 Ibs 238 Ibs 238 Ibs Max Utilization=0.10 Page 4 of 4 V'V1 nIi ' Sol a ar r"f _ � cnad,an ?ems. �n-Buck 10N0 PERC module N1�pCK Nigh density 320 340,wo'335134OW S C51M-320, MORE POWER Or area, Product warranty on materials the tight abs Ption o UP to 20.1 r, /o 5� enhanced prod * mode lze and workmanship uP So module eff+ciencY �YeroNmu n1 max ): Cow temperature coefficient tP°� ut warranty* 5�, p ower outp � 2, linear arranty5tatemenL ears ited W ............. '. SolarLifn .......... '"°""`dJ ticableCanadian .---.-•••,-,... to the aPP .................. *. Better shading tolerance .pccordin9----'•----•.••••.-,....... .� ............ ENT SYS-CEM CEP-'�FICATES MANA�EM en,system entsystem Qua managem entat managem health&safety 150 goal 20151 Q dards for en�ironm for occupational MORE REl1AB►E ISO 14001' Stan DFt5A518001t20071Internationalstandar s Cower internal current -RFICA es* erature Cr CEP., GE r MCS U51 FSEC NS Florida) lower hot spot temP pRODV 61730:VOE listed t iOn. IEC 612151 IK erformanCe:CEC reg 61715 P \jt)r C 62716:VDE risk limited In smallUL 17031 IEC Cell crack reliability 01 CSA l IEC 61701 ED2: r� MO UC 17 LV) enhanCe them Take e Nay ���;CEa7 contaaYour re � markets.Please to the w load uP to 5a400 Pa, 0VE 09-us( s eoflc certkflcates apptiwbte ceriifiicatio,"nOtIve r the SP b eus d, Heavy Snow t0 2g00 p re different re reth are to wind load P As there a solar sate whp h the products...........................id-i gh t+,•,,-".,a local Cana�ithe region •,-•„ mitt2d to ProV'id-trt9 h't 5eNices to Products ..... 58LARINC.is com uality stem solutions an tier for Q CXNADWA Products,solar system module supplier er Insight quality solar P d the world-NO Module Custom facturer customers aroun ratio In tHs er and mal erformancelprice develop d the world and P roject W deployed around Survey•As a leading ri o over 38 C •••"'•-•• Of solar modules --.....- ............. since 200 lar.com canadianso .............................. ................... com,support@ anual. solar atfon,Please refer tol.nsta0ation M Canada wwrT!• canadian •pordetaitinform ..•....................•ei hr Ontario N1KIE6, `A.NAoi�N SOi AR INC. 545 Speedvaie Avenue'Nest,rau p ENGINEERING DRAWING(mm) CS1 H-330MS/I-V CURVES Rear View Frame Cross Section A-A A A _35 _180- 12 - - 135 - 10 --- 10 I 9 ... . . ....... . _ _. 9 7ml e. _. _ _ - ___- _ -___ -- 8 &faaq ! ! fr1 7 - - -_ 7 - - - hio,:,ron(�nar 6 - - - 6- - - 4 -- _._ 4 n - - Mounting Hole 3 2 V ° V / 5 10 15 20 25 30 35 40 45 50 5 10 15 20 25 30 35 40 45 50 _T___.i -_' Gmuaa��g�o:< A •.A I r ■ 1000 W/m' 5'C■ ■ 800 w1w 25'C■ 944 - - 192. - - ■ 200 W/w ELECTRICAL DATA STC* MECHANICAL DATA CS1H 320MS 325MS 330MS 335M5 340MS Specification Data Nominal Max.Power(Pmax) 320 W 325 W 330 W 335 W 340 W Cell Type Mono-crystalline Opt.Operating Voltage(Vmp) 36.2 V 36.6 V 37.0 V 37.4 V 37.8 V Dimensions 1700 x992 x35 mm Opt.Operating Current(Imp) 8.85 A 8.88 A 8.92 A 8.96 A 9.00 A (66.9 x39.1 x 1.38 in) Open Circuit Voltage(Voc) 44.0 V 44.1 V 44.2 V 44.3 V 44.5 V Weight 19.2 kg(42.3 Ibs) Short Circuit Current(Isc) 9.41 A 9.45 A 9.49 A 9.53 A 9.57 A Front Cover 3.2 mm tempered glass Module Efficiency 18.98% 19.27% 19.57%19.86% 20.16% Frame Anodized aluminium alloy Operating Temperature -40°C-+85°C J-Box IP68,3 bypass diodes Max.System Voltage 1000V(IEC/UL) Cable 4.0 mm2(IEC),12 AWG(UL) TYPE 1 (UL 1703)or Cable Length 1350 mm(53.1 in) Module Fire Performance CLASS C(IEC 61730) (Including Connector) Max.Series Fuse Rating 15 A Connector T4 series or H4 UTX or MC4-EVO2 Application Classification Class A Per Pallet 30 piecesPer Container(40'HQ) 780 pieces Power Tolerance 0-+5 W -Under Standard Test Conditions(STC)of irradiance of 1000 W/m',spectrum AM 1.5 and cell temperature of 25'C. ELECTRICAL DATA I NMOT* TEMPERATURE CHARACTERISTICS CS1H 320MS 325MS 330MS 335MS 340MS Specification Data Nominal Max.Power(Pmax) 236 W 240 W 243 W 247 W 251 W Temperature Coefficient(Pmax) -0.37%/'C Opt.Operating Voltage(Vmp) 33.4 V 33.7 V 34.1 V 34.5 V 34.8 V Temperature Coefficient(Voc) -0.29%/°C Opt.Operating Current(Imp) 7.07 A 7.11 A 7.14 A 7.17 A 7.20 A Temperature Coefficient(Isc) 0.05%/'C Open Circuit Voltage(Voc) 41.0 V 41.1 V 41.2 V 41.3 V 41.5 V Nominal Module Operating Temperature 44±3°C Short Circuit Current(Isc) 7.60 A 7.63 A 7.66 A 7.70 A 7.73 A *Under Nominal Module Operating Temperature(NMOT),irradiance of 800 W/m'•spectrum AM 1.5,ambient temperature 20°C,wind speed 1 m/s. PARTNER SECTION .......................................................................................................... The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement.Canadian Solar Inc.reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. .......................................""""'........................................................... ................................................................................................................................................................................................................................................ CANADIAN SOLAR INC. 545 Speedvale Avenue West,Guelph,Ontario N1 K 1 E6,Canada,www.canadiansolar.com,support@canadiansolar.com December 2019.All rights reserved,PV Module Product Datasheet V5.583 EN Single Phase Inverter • - C with HD-Wave' Technolo gy m for North America X SE3000H.-US / SE3800H.-US / SE5000H-US / SE6000H-US / SE760OH-US / S'E10000H-U,S / SEI140OH-US - =—- .�;;� .. - m solar ® solarZ-=' ..rirl:ove j C J ® 9 '0 J p 1 Optimized installation with HD-Wave technology / Specifically designed to work with ! Extremely small power optimizers 0 Record-breaking efficiency ® Built-in module-level monitoring Fixed voltage inverter for longer strings ® Outdoor and indoor installation ® Integrated arc fault protection and rapid shutdown for ® Optional: Revenue grade data,ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) / UL1741 SA certified,for CPUC Rule 21 grid compliance solaredge.com solar , 71 / Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US OUTPUT 3800 @ 240V 6000 @ 240V 11400 @ 240V Rated AC Power Output 3000 3300 @ 208V 5000 5000 @ 208V 7600 10000 ! 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 1o000 @ 208V AC Output Voltage Min.-Nom.-Max ✓ ✓ ✓ I ✓ ✓ ✓ ✓ I Vac (211-240-264) i AC Output Voltage Min.-Nom.-Max. ✓ ✓ i ✓ Vac (183-208-229) l AC Frequency(Nominal) 59 3-60-60.501 Hz Maximum Continuous Output 12 5 16 21 25 32 42 47.5 I A Current @240V Maximum Continuous Output 16 24 48.5 A Current @208V - - 1 GFDI Threshold I A Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 I 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @24OVIII 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V121 - 9 13.5 I 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kQ Sensitivity Maximum Inverter Efficiency 99 99.2 I % CEC Weighted Efficiency gg 99 @ 240V 96 98 5 @ 208V Nighttime Power Consumption <2.5 I W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional'' Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL16998,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range Y Maximum/14-6 AWG 1'Maximum/14-4 AWG A g DC Input WG Range Conduit Size/r of Strings/ I"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG I Dimensions with Safer Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 i 213 x 14.6 x 7 3/540 x 370 x 185 in (HxWXD) / mm Weight with Safety Switch 22110 25.1/114 26.2/11.9 38 8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -13 to+140/-25 to+60i 1(-40'F/-40`C option)°' 'F/'C Protection Rating NEMA 4X(Inverter with Safety Switch) •11 For other regional semngs please contact SolarEdge support ••1 A nigher current source may be used;the inverter will limit its input current to the values stated Revenue grade inverter P/N SExxxxH-US000NNC2 "For power de-rating information refer to https//%rvw.5cla(edge.com/sites/defauit/fileS/se-temperature-derating-note-na pdf i"-40 version P/N:SExxxxH-US000NNU4 'C S01arEdge Technologies.Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED 3Y SOLAREDGE are trademarks of registered trademarks of SolarEdge Technologies,Inc.All ®A.9 other trademarks mentioned herein are trademarks of their respective owners.Date:032019/V01/ENG NAM.Subject to change without notice. II��!