Loading...
HomeMy WebLinkAbout20-896 D t 1 Q �� ► \° ' City Of Zephyrhills PERMIT I NUMBER 5335 Eighth Street f Zephyrhills, FL 33542 ELCMISC-OO"96-2020 Phone: (813)780-0020 ' Fax: (813)780-0021 Issue Date: 10/20/2020 Permit Type: Electric Service Replacement/Misc 3 TRWIb-"i°"LSfii••' $.;.f' -iE3,e. - - " Property Numtier _ ,=; ;; ,t :eStr�eet Address 13 26 210140 00000 0480 39687 Meadowood Loop Owner n ormation,- 'Pe mit lnformati n. ' Contractor Information Name: DAVID PELL Permit Type:Electric Service Replacement/M Contractor: ESD HOME SOLUTIONS Class of Work:Add/Alter Residential y/�Address: 39687 Meadowood Loop Building Valuation:$0.00 ZEPHYRHILLS,FL 33542 Electrical Valuation:$32,400.00 Phone: (813)893-1905 Mechanical Valuation: Plumbing Valuation: r Total Valuation:$32,400.00 Total Fees:$303.00 Amount Paid:$303.00 Date Paid:10/20/2020 1:57:49PM Project Description INSTALLATION PHOTOVOLTAIC SYSTEM Application Fees011 Electrical Plan Review Fee $101.00 Electrical Permit Fee $202.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNty PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INSTR#20201 72516 OR BK 10196 PG 3182 Page 1 of 1 10/14/2020 01:00 PM Rcpt:2215308 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller PREVARtU 8Y:LZU HUME bULU I IONb LL4 7201 BRYAN DAIRY RD LARGO FL 33777 Permit Number Parcel ID Number NOTICE OF COMMENCEMENT State of FI Ida THIS f.RL4IS.w cSEP"JF...r,•POR CLERK OF riIE.COURT CERTIFICATION County of e � THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property,and in accordance with Section 71 Florida Statutes,the following information is provi ed in this NOTICE OF COMMENCEMEN . �� ��: �° 1.Descriptiort of Property(!spar descripffon U �.f-''• 2.General description of improvements: INSTALL SOLAR PV SYSTEM 3.Owner Information or Lessfik mIbriQM if the Lessee contracted for the impro ement: b)Name and address of fee simple titleholder(if different than Owner listed above) N/A c)Interest in property: 100% 1 4.Contr2ctor Information Ld a)Name and address: ANDREW HALL-ESD HOME SOLUTIONS LLC-6076.Park Blvd N Pinellas Park,FL 33781 Q I-- U W J b)Telephone No.: 727.744.0716 Fax No.:(optional) N/A (L o 6,Surety(if applicable,a copy of the payment bond is attached) 0 z m o F- [J1 J :J��; a)Name and address: N/A W 0 _ < o LU b)Telephone No.: a w z - 0 o c Amount of Bond: $ _ _ 0 m �- Q ¢ Y 8.Lender o 0 � 4 W a)Name and address: NIA w o 0 Cr b)Telephone No.: ca? �� to o LU. 7.Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Sectisna. U ro o L 0LL � m � o0 713.13(1)(a)7.,Florida Statutes: F I r m a)Name and address: N/A 0 u C-, r-. z p w b)Telephone No.: Fax No.:(optional) 8.2.ln addition to himself or herself,Owner designates N/A of 1- . " U) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. z b)Phone Number of Person or entity designated by Owner: = cc z ~ Y } 9.Expiration date of notice of commencement(the expiration date may not be before the completion of construction and final payment to the z m contractor,but will be 1 year from the date of recording unless a different date is specified): 20 WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT, Under penalty of perjury,I declare that I e rea a foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. (Signature of Owner r essee,or Owners or Lessee's(Authorized Officer/Director/Pattner/Manager) (Print Name and Pro a Signatory's Title/Office) The foregoing Instrument was acknowledged before me this 1 8n day of , ,V4� Mr 20 %ZO by �U)C j �K as �udmr- --- (type of authority,e.g.officer,trustee,attorney in fact) for ,as j (Name of Person) (type of authority....e.g.officer,trustee,attorney in fact) for (name of p rty on beh If of whom instrum s executed). I Personally Known ❑ Produced ID Type of ID DL Notary Signature Print name '�t tr1\� ,TIFFANY M. HIGGINS Notary:Publie-State of Florida '' •'- Commission 0 HH 38358 MY Commission Expires "rrrrr�` September 01,2024 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received 1071 Phone Contact for Permitting — .aaaaaaaa ausaaamasaaaa Owner's Name ' Owner Phone Number " Owner's Address 13q6A7 fVVec6,,j06 Gi Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 16/IK7 nnine4aouxiock LOT# / SUBDIVISION CCfCLXAJOO I PARCEL ID# _ (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR B ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR Q COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK BUILDING SIZE SQ FOOTAGE HEIGHT =BUILDING $' VALUATION OF TOTAL CONSTRUCTION ELECTRICAL 0 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ � =MECHANICAL $ VALUATION OF ME HANICAL INSTALLATION =GAS ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO V BUILDER COMPANY SIGNATURE F REGISTERED Y/N FEE CURREN Y/N Address License# 1 � ELECTRICIAN /f COMPANY S SIGNATURE REGISTERED Y/N FEECURREN I Y/ Address 7 6 &-K C(/ License# t4fJ.2yJ'et PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y I N Address F License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN I Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address I License# _■■_a a a.Ca a s IIIXN_a.a.a aa.La_a a a_a.a a i a a a■.a a i_a.a■.a a a a a a 2.v_a a a a a■.a.a.a.■a.a.a a.a-a,a■K-1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet Compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. Drrectrons: % % _ ———— ——_—_ —e_— Fill out application.completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW Energy - Sob Dired 6076 Park Blvd N -Pinellas Park, FL 33781 727-744-0716 Ak - I, Andrew Hall , license holder for Energy Solutions Direct authorize the following people to apply/sign for permit under my license number EC13008844 +A Please allow ONLY the persons listed below:This letter will supersede aILothers.,. Bruce Reviere Phillip Reyes Doug Burlett Catherine McCarthy Quinton Polisena Andrew Hall License Holder Signature- License Holder Printed Name State of Florida County of Pinellas The forgoing instrument was acknowledged before me this /f day Of 0 C, ,20_Lg by Andrew Hall who is personally known to me or has produced for identification. tipvB ��.•�-.�v� J=RANCES M RICE � � Commis��GG222864 y`'�°�Fl°E'er Bated i May29'20n Notary Public ` " 613-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed In accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at-the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy'or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit Issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes;as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in goad faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that It is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall became invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT, FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Sub ribe and swam to or ffirmed yfor his Sub) nd swam to(o ff/rmed befo�q s /a/ !O / Ev�,l /�/N by /C y� Who is/are persbQaUXJn5a.0me or has)fiave produced Who is/hrellpa to me or has/have roduced as identification. as identification. Notary Public ���� f Notary Public Commission No. Commission No. Qo•.,aS � ..J—�b(r'k �d� �v�'l[?-<F� r�eVR�" a�0316 Name of Not typed,printed or stamped 16 Name of NoWry typed,printed or stamped 0 `O� Ga�`�12p23 ®0®Z�3 p29 ,I puait� CO��\aNpVO�o N°vHaON� O0\® �O9ry` Z�r?.•... �XQ\lg���®ado ypUBl/c ®�®V��`�g1Dt� T4rF of iv x sTR)E OFt� DIRECTORY OF PAGES SCOPE OF WORK P-145386 PV-1 PROJECT SUMMARY O THIS PROJECT INVOLVES THE INSTALLATION OF A ____ O PHOTOVOLTAIC POWER SYSTEM.SOLAR PANELS WILL BE 0 PV-2 SITE PLAN RACKED USING A PREENGINEERED RACKING SYSTEM.THE o RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH Energy PV-3 SINGLE-LINE DIAGRAM DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE 0 PV-4 SAFETY LABELS o O LOCAL UTILITY USING MEANS AND METHODS CONSISTENT PV-5 ATTACHMENT PLAN a -J PERMITTI G JURISDICT ON.ENF0RCED BY THE LOCAL UTILITY AND Solutions Direct PV-6 ATTACHMENT DETAILS o THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF PV-7 FIRE SAFETY PLAN W 213 DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH MODULE DATASHEET . ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH H- O APPLICABLE CODES AND REGULATIONS.THE DOCUMENT (1) ARRAY WIRING BOX DATASHEET SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR >< FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. (I) Ei ARRAY WIRING BOX DATASHEET THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS W J M LISTING AND INSTALLATION INSTRUCTIONS,AS WELL AS ALL o M z INVERTER DATASHEET APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE LLl Z 0 J a. MOUNTING SYSTEM DATASHEET INTERPRETED IN A WAY THAT OVERRIDES THEM. Q CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL 0 0 O - UL 2703 GROUND AND BONDING CERTIFICATION CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT. (n ANCHOR DATASHEET W @iEJb Map data @2020 SYSTEM DETAILS PROJECT DETAILS NEW GRID-INTERACTIVE J J W > 1 PLOT DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO U) J >- PROPERTY OWNER PELL C/� W BATTERY STORAGE 39687 MEADOWOOD LOOP, PV-1 SCALE: NTS a ti PROPERTY ADDRESS DC RATING OF SYSTEM 8.00KW 00 ZEPHYRHILLS,FL 33542 US W Cfl N ZONING RESIDENTIAL sss AC RATING OF SYSTEM 6.00KW M AC OUTPUT CURRENT 25.OA USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING ® 0 CLASSIFICATION GROUP(GROUP R3) �.� Zephythills INVERTER(S) 25 X ENPHASE IQ7-60-2-US w ® N6rt AHJ CITY OF ZEPHYRHILLS MODULE AXITEC AC-320MH/1205 UTILITY COMPANY DUKE ENERGY FLORIDA (1)BRANCH OF 13 IQ7-60-2-US MICROINVERTERSMETER SERIAL 1a21uii ELECTRICAL CODE NUMBER 4420102571 4 NEC(NFPA 70) Zephyrhills Zephyrhills Hillsba Upper h c ARRAY WIRING (MICROINVERTERS BRANCH OF 12 IQ7-60-2-US Skydive CityfZ�9 Preserve FIRE CODE 2015 NFPA 1 4t �' Zephyrhills INTERCONNECTION DETAILS *' 7S9 OER CODES TH BUILDING 2017 FL BUILDING CODE South POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECTION ' PER NEC 705.12(A) CONTRACTOR INFORMATION % O UTILITY SERVICE 120/240V1� � O R c,:��••' COMPANY ENERGY SOLUTIONS DIRECT 'yam LICENSE NUMBER CBC1260807 Crystal Springs SITE DETAILS ADDRESS 7965 9TH AVE S,ST.PETERSBURG, ASHRAE EXTREME LOW 1°C(34°F) PROJECT ST.PETERSBURG,FL 33707 ASHRAE 2%HIGH 34°C(93°F) SUMMARY PHONE NUMBER (800)425-1175 ■ . 'r 3aT Map data @2020 Goggle CLIMATE DATA SOURCE ST.PETERSBURG CLEAR(KSPG) CONTRACTOR DOC ID:145386-179701-0 SIGNATURE 2 LOCALE WIND SPEED 145 MPH(ASCE7-10) PV-1 SCALE: NTS RISK CATEGORY I I DATE:9/22120 WIND EXPOSURE B CREATOR: QC 1 CATEGORY REVIEWER:P.C. ALL WORK � PREViAILING l GROUND SNOW LOAD 0 PSF REVISIONS �T� OF 1P I AND EC ` tLLS PLAN ORDINANCES Pv-1 N GENERAL NOTES P-145386 EQUIPMENT LIKELY TO BE WORKED UPON WHILE 1 ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. Cot) CONTRACTOR SHALL USE ONLY COMPONENTS LISTED Energy 2 BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. Solutions Direct CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL 3 EQUIPMENT,CABLES,ADDITIONAL CONDUITS, RACEWAYS,AND OTHER ACCESSORIES NECESSARY L,UJ FOR A COMPLETE AND OPERATIONAL PV SYSTEM. F O N (N)TRANSITION BOX(JB1),OUTDOOR,OUTPUT 1OCIRCUIT CONDUCTORS SHALL BE RUN IN LFMC U 0 0 M CONDUIT THROUGH THE INTERIOR OF THE BUILDING W z J (N)AC COMBINER(Cl),OUTDOOR,OUTPUT CIRCUIT OCONDUCTORS SHALL BE RUN IN LFNC CONDUIT OVER 0 0 O ROOF NO CLOSER THAN 0.5"ABOVE ROOF SURFACE (n (N)PROPOSED ROOF-MOUNTED PHOTOVOLTAIC &5o ARRAY.6:12(27°)SLOPED ROOF,25 PV MODULES (SILVER FRAME,CLEAR BACKSHEET),203°AZIMUTH Q _ J Q 4O (E)MAIN SERVICE PANEL(MSP),OUTDOOR 0 J W Of (N)VISIBLE,LOCKABLE,LABELED AC DISCONNECT C1) W OLOCATED WITHIN 10 FT OF UTILITY METER(SW1), 0 W OO 0- OUTDOOR W W (E)UTILITY METER,OUTDOOR N 0C ) 7O ROADWAY ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH (� THE INTERIOR OF THE BUILDING,AND WHERE 8 POSSIBLE,ALONG THE BOTTOM OF LOAD BEARING MEMBERS.NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF w�Q� .0 E IYs••� 1 r 5962 •* 4 5 ≥j• 6 SITE PLAN 1 SITE PLAN DOC ID:145386-179701-0 DATE:9/22/20 PV-2 SCALE: 1"= 10' CREATOR: REVIEWER:P.C. • REVISIONS . °.---'-- I :'- �4 PV-2 LE ND ESO SOLAR ®® �_E..�..F.,�,•��. LI SUPPLY SIDE CONNECTION L2 NLIMITEII N _ ENGINEERING G S O L U T 1 0 !N 5 (3) #6 AWG THHN/THWN-2 3/4" EMT, FMC,PVC, LFMC, LFNMC CONDUIT. (3) #6 AWG THHN/THWN-2 Lu (I) #10 AWG THHN/THWN-2 (EGC) rH 3/4" EMT, FMC,PVC, LFMC, LFNMC CONDUIT. W f 0 METER w ❑ OO (#) #10 AWG THHN/THWN-2 (1) #10 AWG THHN/THWN-2 (EGC) O 3/4" EMT, FMC,PVC, LFMC, LFNMC CONDUIT. CL Q O NO.1 NO.2 N0.3 NO.12 J n n I-I lr O wI I SOLADECK.600VCL - �-t -- - - - ��pp�qq�� I I NON-FUSED OR I I ❑ N N Io L6 M za NEMA 3R PVC ROOFTOP II # SPACE �] Zo JUNCTION BOX O) II II F 0) 0 NEUTRAL GROUND • • • N r0 L II V NO.1 1 NO.2 NO.3 NO.13 li- f SEAL PV AC DISCONNECT LOCKABLE FUSED �� ��•••� E N •• +i 60A OR IOOA 240V 2-POLE /_(25) AXITEC 320MH .,R �° ••. + NEUTRAL GROUND 35A RK-I FUSE 120S W/ ENPHASE IQ7-60--2-US '* 75962 MICRO INVERTER. TYP. ENPHASE Q CABLE1 OEXIA PANEL BOARD / BUSBAR NEUTRAL BONDED TO GROUND (2) CIRCUITS OF LI & L2 STING 150A MAIN BREAKER 120/240 VAC #6 AWG BARE COPPER GEC TO EXISTING (1) #6 AWG EGC +�" c e O�d GROUNDING ELECTRODE NEC 250.64(8) +i s'••...•••..•• PV WIRES MUST BE USED FROM INVERTERS TO _0 NA L SIGNATURE EXISTING GROUNDING ELECTRODE J.BOX FOR LI & L2. EGC WIRE MUST BE #6 FROM INVERTERS TO J.BOX; TYP. ELECTRICAL r DIAGRAM METER OPTIONAL LOAD SIDE CONNECTION 1 I O ALLOWABLE LOAD SIDE CONNECTION I BUSBAR RATING 200A I DRAWN BY: B.C. MAIN BREAKER SIZE 150A (Bus RATING *1.2)-MAIN BREAK SIZE 90A I REVIEWED BY: P.E.C. I REVISIONS _-/1 35A n #8 AWG THWN 1 (2)HOT I - - • 1-t- • - • - - (1)NEUTRAL I NOTES: (1)#10 AWG EGC IN 3/4"PVC CONDUIT I. ALL INVERTERS ARE EQUIPPED W/ INTERNAL RAPID SHUTDOWN SYSTEM AS PER NEC 690.12. PV-AC DISCONNECT LOCKABLE FUSED I 2. ALL LINES TO HAVE TERMINATOR AND SEALING CAP INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS. 60A 240V 2-POLE I GE C 35A RK-I FUSE I 3. OPTIONAL LOAD SIDE CONNECTION: WHEN FEASIBLE, PER NEC SECTION 705.12(D)2. OTHERWISE PANEL BOARD MUST BE UPGRADED TO 200A PV103 L - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - OLAR C9® VILA AITEI] ENGINEERING S O L U T I O N S SUPPLY SIDE ELECTRICAL NOTES: I. ALL WORK TO MEET OR EXCEED NEC 2014 REQUIREMENTS 2.ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT PRESENTED IN THIS DOCUMENT SHALL COMPLY WITH MANUFACTURERS RECOMMENDATIONS, SPECIFICATIONS AND COMPLY WITH ALL CODES, STATUTES AND STANDARDS ADOPTED BY THE liJ STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. I-' r � 3.INTERCONNECTION VIA SUPPLY SIDE CONNECTION AS PER NEC 705.12(A) USING PARALLEL TAPS v! IN A NEMA 3R BOX (AS REQUIRED) USING NSI IPCS 4002, ILSCO KUP-L-TAP INSULATION CJ) PIERCING PIERCING CONNECTORS, OR EQUIVALENT. vl WARN IN G 4.PV DISCONNECTING MEANS FOR SUPPLY SIDE CONNECTION MUST HAVE NEUTRAL/EGC BOND ❑ WITHIN AND MUST BE LISTED AS " SUITABLE FOR USE AS SERVICE EQUIPMENT" NEC 230.66. �J 5.ROOFTOP JUNCTION BOX MUST BE MINIMUM NEMA 3R UL LISTED ENCLOSURE. FREE AIR I _I O ELECTRICSHOCK HAZARD , © CONDUCTORS MUST BE INSTALLED IN RACEWAY OR GUARDED, IF READILY ACCESSIBLE AS PER NEC 690.31(A). O THE DC CONDUCTORS OF THIS 6.THE FOLLOWING LABEL IS REQUIRED ON METER CAN AND PANEL BOARD: " WARNING: DUAL a"' _ Q SYSTEM POWER SUPPLY. SOURCES: UTILITY GRID AND PV POWER SOURCE ELECTRIC SYSTEM" AS PER �� /� /i�PHOTOVOLTAIC h NEC 705.12(D)(3). _ ,< > ARE UNGROUNDED EI AND MAY • r 7.THE PV AC DISCONNECTING MEANS SHALL BE MARKED TO IDENTIFY AS THE: " PV SYSTEM _j W 0- A B)p�n��scc� E ENERGIZED DISCONNECT" IC PEKNEC EQUIPPED WITH RAPID SHUTDOWN" LABEL REQUIRED ON PV SYSTEM O Q-- 8. PHOTOVOLTAIC SYSTEM U T T DISCONNECT MEANS AS PER NEC 690.12(4) & 690.56(C). ❑ 00 LOCATIONS: PV LOCATIONS: MAIN PANEL BOARD & UTILITY 9." WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE J.iJ (O DISCONNECTING MEANS METER CAN LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION." REQUIRED ON PV SYSTEM G) DISCONNECTING MEANS AND THE INVERTER AS PER NEC 690.17(E). z 4"M J 10. ALL WARNING SIGNS OR LABELS SHALL COMPLY WITH NEC 110.21(B). 11.ALL COMPONENTS TO BE GROUNDED AS PER NEC 690.43. !^� Ll SEAL Q1��E - - - - - - - - - - - - - - - - - - - LOAD SIDE ELECTRICAL NOTES: I a. .. ..; ALL WORK TO MEET OR EXCEED NEC 2014 REQUIREMENTS ��,, � ` •'�,• • . *� 75962 I ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT PRESENTEDIN I JTHIS DOCUMENT SHALL COMPLY WITH MANUFACTURERS RECOMMENDATIONS,SPECIFICATIONS TEC 0 UR NT A I AND COMPLY WITH ALL CODES, STATUTES AND STANDARDS ADOPTED BY THESTATE AND THE I ' O: �� pk, fix OPERATING VOLTAGE LOCAL AUTHORITY HAVING JURISDICTION. •�.�`s.•� 6 [ NIL P!E TINA 0LTA E I INTERCONNECTION WITH 35A OCPD (CKT BRK) VIA 705.12(D)(2)(3)(B) LOAD SIDE I °��� /p�' •��� ______ 5' I CONNECTION.THE 35A BACK FED BREAKER MUST BE LOCATED AT THE OPPOSITE END OF THE I �_____ ���f���sIGNATURE BUS FROM THE 150A MAIN SUPPLY BREAKER. I LOCATIONS: MAIN PANEL BOARD & UTILITY RATED AC CURRENT: 25A I ROOFTOP JUNCTION BOX MUST BE MINIMUM NEMA 3R UL LISTED ENCLOSURE. FREE I METER CAN NOMINAL AC VOLTAGE: 210V I AIRCONDUCTORS MUST BE INSTALLED IN RACEWAY OR GUARDED, IF READILY ACCESSIBLE AS ELECTRICAL PERNEC 690.31(A). I NOTES LOCATIONS: PV DISCONNECTING I THE FOLLOWING LABEL IS REQUIRED ON METER CAN AND PANEL BOARD: " WARNING: I MEANS, MAIN PANEL BOARD, & AC I DUALPOWER SUPPLY. SOURCES: UTILITY GRID AND PV POWER SOURCE ELECTRIC SYSTEM" AS COMBINER PANEL I PERNEC 705.12(D)(3). THE PV AC DISCONNECTING MEANS SHALL BE MARKED TO IDENTIFY AS THE: " PV DRAWN BY: B.C. SYSTEMDISCONNECT" AS PER NEC 690.13(B) I REVIEWED BY: P.E.C. " PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN" LABEL REQUIRED ON PV SYSTEMDISCONNECT MEANS AS PER NEC 690.12(4) & 690.56(C). I REVISIONS I " WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH IN CASE OF EMERGENCY, CONTACT I THELINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION." REQUIRED ON PV I ENERGY SOLUTIONS DIRECT AT SYSTEMDISCONNECTING MEANS AND THE INVERTER AS PER NEC 690.17(E). I ALL WARNING SIGNS OR LABELS SHALL COMPLY WITH NEC 110.21(B). 1-800-425-1175 I I ALL COMPONENTS TO BE GROUNDED AS PER NEC 690.43. PV,4 SKYCIV LOAD CALCULATION REPORT WEND PRESSURE RLSLJLT X-�l ARCOC30 •r•.�...��a.�. �srs U�za AKzl�i'O NL_Ir PROJECT DETAILS ENGINEERING S O L U T I O N S ;e I Proletat Name: DA4t D P E.1 Project dniu: Irrnerial Project.D. U) ^^ Project Company: EN ERGY SCILLITION5 DIRECT f >— Project❑esigner. PECRO E CRUZ.PE 4 y tZLsie 5 U ❑ PrejectCllenC — � LL1 r n h d Q ` v. Project Notes: (`..l _—i SITE DETAILS ❑ Ccdesdecte3: ASCE71a L o u u, r 1-Li PiskCategc-' Riskcatryl� — _ '�, N ❑ co Fxua re: H iJ..l C9 Sate Location: 39687 Meadow ce!cor3,ZehyrhiiIs,FL 33542,US 0) Where'a=4..WotT 1 Site Wind Speed: 140 mph ❑_y Site Elevatiaan_ 90.15 ft �LrL1 Ground Snow Load-p,a 0PSf Wind Pri ssure for Carnpanents and Cladding - Chapter 3O of ASCE 7-1O(Parts I and 3) �✓ �►trata r��y� STRUCTURE BATA r1csEr Pr ;14Larw rrsf SEAL +y O Area of Claddir►g ri+a-cr Elewatir�n �� Qd ,..•ti•.,, CI!, Lype of Claddl n (t Ls vtI ft �assc �����;.• C E!yS••�{i�i Irmo a drsrw ? lnrse i Cprw 4 Z-a rw 4 �Q • �. 0,• �arameler Value ivt'1;s 33.224 3_•. .'c *s 962 �• :::::: 4T,x+ O 3� -69.463 ,,,��0 Itf�1� SIGNATURE HteanRcsollieag�^t 15tr_ Fr'r.ttLa6Jtng• CJaz rh u� Mirr 054 3tJ 0l T ?2rr7f a;:tN ltragle 25 tsa tze�t ATTACHMENT DETAILS • 40 ,. DRAWN BY: B.C. 160 REVIEWED BY: P.E.C. ..,•..,.M...,..,,.•....•„., 170 "�'�"`•�"•�'�"•""" REVISIONS • I. i ..r.wxiax a,.,s.•.wxay. 15® Y• •• ;._....-«r,w¢w<n•:+u w�w.., 170 '° � r�.i:3., a.l,l:r w•s..per 188 — Mao doss 792B4na�vAlD0ITemiefWa 4tnen ROOF PROPERTIES P-145386 ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) SLOPE 6/12(26.6°) 00 MEAN ROOF HEIGHT 13.7FT RIDGE Energy O DECK SHEATHING 19/32"(5/8"NOM.)PLYWOOD I ! I I I 1 CONSTRUCTION TRUSSES(2X4 TOP-CHORD),241N OC I i Solutions Direct MODULE MECHANICAL PROPERTIES W 1 1 1 ! 1 1 1 II I I I I W MODEL AXITEC AC-320MH/120S I- II III I I I I I I oac C1) DIMENSIONS(AREA) 65.91N X 39.11N X 1.41N(17.9 SQ FT) >-- O d'- WEIGHT 40.81-8 I I I I I I I I I 1 I I I O I I I I W J M U p MOUNTING SYSTEM PROPERTIES I I I 1-z O -j RAIL MODEL N/A I 1 I ANCHOR MODEL EAVE o J ECOFASTEN SOLAR ROCK-IT 3.0 )I i Q J FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES J _ WITH(1)5/161N LAG SCREWS WIND ZONE I WIND ZONE II WIND ZONE III O W MAX.ALLOW.RAIL SPAN 48.01N(ZONES 1,2, AND 3) C/) W MAX.MOUNT SPACING 48.01N(ZONES 1,2, AND 3) DISTANCE a IS EQUAL 1O 10%OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40%OF THE MEAN ROOF HEIGHT,WHICHEVER IS SMALLER,BUT NOT LESS THAN 4%OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET(ACSE 7- O UJ MAX.ALLOW. 10).THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS,RAKES,HIPS,EAVES,MANSARDS,AND RIDGES OF ROOF FACES. W Cfl N CANTILEVER 16.0IN(ZONES 1,2, AND 3) a=MAX(MIN(0.4*MEAN ROOF HEIGHT,0.1*LEAST HORIZONTAL DIMENSION), 0.04*LEAST HORIZONTAL DIMENSION,3 FT) ~ M GROUNDING AND INTEGRAL GROUNDING CERTIFIED 4.9 FT=MAX(MIN(0.4*13.7 FT,0.1*48.8 FT), 0.04*48.8 FT,3 FT) BONDING TO UL 2703 REQUIREMENTS ATTACHMENT PLAN ORTHOGONAL PROJECTION O NOTES PV-5 SCALE: 1/8" = 1' TRUSS LOCATIONS ARE APPROXIMATE.ACTUAL 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED O,,O-0 E•,,•c��i�� TO ADJUST MOUNT LOCATIONS.IN NO CASE SHALL THEC MOUNT SPACING EXCEED"MAX.MOUNT SPACING" •••Q�,•' Ns�•;G�`� PER ENGINEERING,CANTILEVER("RAIL END 2 OVERHANG")"IS NOT TO EXCEED 33%OF ACCEPTABLE RAIL SPAN"DEFINED IN THIS DOCUMENT AS"MAX. ALLOW.RAIL SPAN". • ATTACHMENT PLAN DOC ID:145386-179701-0 DATE:9/22/20 CREATOR: REVIEWER:P.C. REVISIONS Pv-5 D E9 SOAR UNLI MITE E) ENGINEERING S o L U T 9 C N S STRUCTURAL NOTES: 48"O.C.MAX. 1. THIS PLAN MAY BE USED WITH ANY MODULE APPROVED BY AN NRTL (NATIONALLY RECOGNIZED ROCK IT 3.0 ROCK IT 3.0 TESTING LABORATORY),AXITEC,CANADIAN SOLAR,SOLAR WORLD AMONG OTHERS. w ROCK-IT 3.0 COUPLING ASSEMBLY COUPLING ASSEMBLY MOUNT (TYP.) (TYP.) (TYP.) 2.THE SOLAR EQUIPMENT INSTALLED WILL ADD LESS THAN 4 PSF GRAVITY LOAD TO THE EXISTING n STRUCTURE. PANELS TO BE INSTALLED ON ROOF PRESSURE ZONE 1. U) n 3.THERE SHALL BE PV-TO-RAIL MOUNTING CLAMP AT EVERY MODULE/RAIL CROSSING POINT WITH >.. ! MINIMUM 4 CLAMPS PER MODULE. ADJOINING MODULES SHALL SHARE GROUNDING CLAMPS. vJ CONTRACTOR SHALL FURNISH END CLAMPS OF CHOICE. �y 4.MODULES MAY BE INSTALLED IN LANDSCAPE OR PORTRAIT ORIENTATION AS PER CONTRACTOR !� PV SYSTEM. OPTION. w O w SEE PV-I. 5.MODULES WILL BE ATTACHED TO ROOF USING A ROCK-IT 3.0 RAIL FREE RACKING SYSTEM. r2i O ,J (TYP.) O > ROCK-I 3.0 6.INSTALLATION METHOD: MOUNT ( YP.) a.FIND THE REQUIRED STRUCTURAL ATTACHMENT POINTS. MARK THESE USING VERTICAL (N-S) [1 Q O CHALK LINE ON THE CENTER OF THE RAFTERS. b.SPACING MAY VARY DEPENDING UPON PROJECT SPECIFIC SPACING IS 48"FOR PORTRAIIT AND 72""FOR LANDSCAPEORIENTATION AL REQUIREMENTS. MAX _j L � 'Gtr PV SYSTEM. c. INSTALL ROCK-IT MOUNTS TO PREDETERMINED MOUNT SPACING. O Qr SEE PV-I. 7.CONTRACTOR SHALL ENSURE CONTINUITY OF ALL METAL PARTS AND CONNECTIONS OF THIS rr nn n r'.J (TYP.) INSTALLATION TO BE ELECTRICALLY GROUNDED AND BONDED TOGETHER AS REQUIRED. Cl) ! 8.CONTRACTOR SHALL PROVIDE AHJ ANY OTHER INFORMATION AS REQUIRED. C� GD 9.DESIGNED AS PER FBC 2017.FLORIDA BUILDING CODE(6TH EDITION). W� 10. CONTRACTOR MAY LOCATE PV MODULES IN OTHER LOCATIONS AND/OR ORIENTATION BUT SHALL F / NOT PLACE PV MODULES IN WIND ZONE 3. ROCK-IT 3.01 ROCK IT 3.01 11. DRAWINGS MAY NOT REFLECT FIELD CONDITIONS. CONTRACTOR SHALL FIELD VERIFY CONDITIONS ry MOUNT (TYP.) COUPLING ASSEMBLY PRIOR TO INSTALLATION. (TYP.) TYPICAL PORTRAIT LAYOUT NOT TO SCALE PV MODULE SEAL �� I�� ,���Qi��.........•C� ROCK-IT 3.0 �� b ;' %CE Ns SYSTEM MAX. % 48"O.C. 16 X"- / HEX HEAD BOLT * , ROCK-IT 3.0 3 33/4-16 FLANGE NUT :9• 5962 ' ROCK-IT 3.0 COUPLING ASSEMBLY MOUNT (TYP ) (TYP.) JL 0 EXT'G UNDERLAYMENT(V.I.F.) PV SYSTEM. EXT'G ROOF STRUCTURE(V.I.F.) S1 %%%��SIGNATURE SEE PV-I. (TYP.) EXT'G SHEATHING (V.I.F.) ATTACHMENT PLANS & DETAILS DIA. SS LAG SCREW 2-Y EMBED MIN. INTO THE ROOF STRUCTURE (I.E. ROOF JOISTS). V.I.F DRAWN BY: B.C. REVIEWED BY: P.E.C. TYPICAL LANDSCAPE LAYOUT TYPICAL SHINGLE ROOF REVISIONS NOT TO SCALE ATTACHMENT NOT TO SCALE (FOR VISUAL EFFECTS ONLY; ALWAYS INSTALL PER MANUF SPECS) I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MYPV,6 SIGNATURE AND SEAL ON THIS DRAWING. O GENERAL NOTES P-145386 ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED OVER OPENINGS(WINDOWS OR DOORS),ARE LOCATED 00 AT STRONG POINTS OF BUILDING CONSTRUCTION,AND Energy ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT O WITH OVERHEAD OBSTRUCTIONS(TREE LIMBS,WIRES, OR SIGNS).(NFPA 1 11.12.2.2.1.3) Solutions Direct PHOTOVOLTAIC MODULES SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO 3 FT WIDE ACCESS 2 PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE THE MODULES ARE LOCATED. W (NFPA 1 11.12.2.2.2.1.2) I- 3 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS O THAN 3 FT BELOW THE RIDGE.(NFPA 1 11.12.2.2.2.2) UJ Q W J M W CO 0 3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 Lu W _j 11.12.2.2.2.1.2 PV MODULES INSTALLED ON ROOF WITH EVEREST 0 0 0 u) CROSSRAIL MOUNTING SYSTEM.THE MOUNTING Cl) O J O2 SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 6/12 W J SLOPED ROOF WHEN INSTALLED WITH TYPE 1,2, OR 3 Q W 0 MODULES.THE AXITEC AC-320MH/120S IS TYPE 1. J J W O3.0 FT.WIDE SMOKE-VENTILATION SETBACK,PER NFPA O J 111.12.2.2.2.2 Cl) W O3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 0 11.12.2.2.2.1.2 W Ui O ROOF ACCESS POINT QC ) ROOF ACCESS POINT O7 ROADWAY TOTAL PLAN VIEW ARRAY AREA IS 414.9 SQ.FT,WHICH 8 REPRESENTS 15.9%OF TOTAL PLAN VIEW ROOF AREA (2611.3 SQ.FT) .fix ,'�QR••.........•('�t�I THIS SYSTEM UTILIZES MICROINVERTERS.THERE ARE ••• �!• c E NS'•. G�i� 9 NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER �• Q; •;� •. OR INSIDE THE BUILDING. *•• No 75962 2 ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH ? v: THE INTERIOR OF THE BUILDING,AND WHERE 10 POSSIBLE,ALONG THE BOTTOM OF LOAD BEARING 3 MEMBERS.NO CONDUIT SHALL BE INSTALLED ABOVE .�'•. O •. THE ROOF ��'� • ...•••• ` 4 ��•afeln FIRE SAFETY • 6 PLAN DOC ID:145386-179701-0 DATE:9/22/20 CREATOR: REVIEWER:P.C. REVISIONS 1 FIRE SAFETY PLAN PV SCALE: 1"= 10' PV-7 ■ �''� � Energy 0 wt+m.axiterrs+slar.us wrrw,axitecselar.us +�r� -n� X«EC® oA- ITEC 31 D - �3L.5 Wp high quality german solar brand high quality german solar brand W H- A XIb!ackpre'mf um HC 3101-325 l'yp >— AXIblacGrpremllum HC � Elaetricd date.(at sraetdard catiditxirls(sTGy iteexliarrc®'I0dD wa#!m'.spectrum f`r::4 i-5 at a t0ell t&,uperature flr 25`Gp 120 cell nlonocr�tstalline ti Typa ta:,rimm 4 n MWAffm rnegte� N m:+w caate t 5h0 t rkd cry++ :A'+er. Mndike Larwtaedan W amt;t '+r+Pu isc Um errsrierny lilgh pertormance solar module ye •r AC-310MFV12DS 31Dwp 32.58V 9.52A 9SSA 3958V 1&66% O German engineered—made for America 4 +r- ' AC-315MHti2055 315V 32.79 V 9.61 A 10.04A 3974 V 1896% 4 r .y AC-320MHr20S 320 tn 3.03 V 9.69 A 10.13 A 39.92 V 19.26% 15 years manufacturer's warranty 4 1 ,y AC 325MH/120S 325V1p 32.71 V 9.93A 10.43 A 4D.10 V 19.56% Five rr'tore years than industry standard ; 4 Q W I!' Highest module performance through 4 y L KVWUM C) Half-Cut-technology and tested materials f 1 y FttnC3dr7 0.13 Yr<n(32 Fl1tP)Iw6e ed. Iec110 rtYile 411ese Sye*&s V6118 t0o0 VOD(IL)10 VOC j1EC) '� Ceti 120 nrorrouysWh m 1,a-✓ae"Mb Positive power tolerance from l 5 Wpcom u tMm kMdlle Fits PerfOnr�ritd TYPE 1(UL 1703} Higher guaranteedyield y Frame 1.38 i�N 35 mrri tt8C4 rdrri5atktm ree,nri a CLASS C{"45*IEC 61730"i W t9 ( ) Nocr(rfornir�el ape�a8n ceo mrr rep iii' 45'C t-2K Max barlmn nQ cigitl0 iy 113 PSF I Snow loa;J of up to 113 psf ■acrsr9rai dens Pevetsewrardleerl IR 20 DA Stable module for a long life in extreme conditions Lx WUH 6594x39.05x1.381rr#a(1575x992x35mtn) Permr$ihlzawatYp r kVL=gfl[ +I079Ibe(1&5 k1 w6h9eme Detmpetet a -40°Ct 85'C1-40Fto1BSF © 100 electroluminescence inspection C) Micro crack and hotspot free modu"es Po..et ctarneian (1 external eetar)ben trio Sodcei Retechm Ciwa IP6B rcmy be Øe0 1c the rccdJle) SEAL a ......... c . Axitec-Soft-Grip-Seam aluminum frame +rrrs 43.sl t,AWr 11 rAMI 5. ♦♦`���•••�C E ••.�G�•� Higher stability and easier handling .ty-a1 eysiern P1r keA +Bd StBudl MC4 aN '�r �wature20°C 1♦ `' ' • High quality junction box and connector system for a longer Ile time Tsmpeeswrrrcarlll jW" :O'• OF ;'4 ,� mm r.a VOtt glo -029%)K ♦ A` .•l �` Exclusive linearA)t1TEC high performance guarantee! egNam:tryIPP -03`J +�I��ONA•� S'GNATURE •15 years manufacturers guarantee on 90%o€the nominal performance •25 years manufacturers guarantee on 85%of the nominal performance $ 2 cam tour It OflO jFx4eripie ltirAc 3oM?120s) mm SPECIFICATIONS 20OWft 1.9cA 3a75V SHEETS 4DOwMP 3.86A 3134 V 579A 31 77 V 871 I $rr tY Add"Val,,r G 20O Wh9' 7.67A 3228 V I I I taDOW4fr 9.52A 3258V 4 86% 95% 1-8,%ri orls power sN 9u% after 25 years P•�•»ho DRAWN BY: B.C. UED cierc1Mod:aaepecesperptlee 30 REVIEWED BY: P.E.C. $evd Warrowfiv (Ph10TOVCLTAIC MODULE Modie pieces pet HC-contmrw 73 W CVM41300 VC4-TSl SJK4 10 r5 W 25 Yoe ra E4a75W Al dinrerrsia,s in Irch REVISIONS TeChrit:tlue w.eyeatfztrry.aetmtpriri nvoe.arrwsrza+pr.d the meuerarti�,ru4rrr t►ra•FSx fl tlel is rr Prr 'M dArts�U. d LroeeMrc ix rirrewrr w• ry owtusr+rea't yr cramP+rk pr.re©ee el rt�mtierne+ecr+anr.ey Tn u.. SPECS G,_E Shot Enphase IQ Combiner 3 Energy 0 Enphase Networking MODEL NUMBER IQ Combiner 3 ICs Combiner 3 with Enphase IQ Envoy"printed circuit board for integrated revenue grade Pv X-IQ-AM1 240-3 production metering(ANSI C12.20./-0.5%)and optional consumption monitoring I;+f-2.5%). ACCESSORIES and REPLACEMENT PARTS(rot included,order separately) Enphase Mobile Connect��CELLMODEM-03(4G112-year data p?an) Plug and play irdastrial grade cellular modern with data plan for systems ua to 60 W CELLMODEM-01(3G/5-year data plan, microinverters.(Available in the US,Canada,Mexico.Puerto Rico.and the US Virgin Islands, CELLMODEM-Ml f4GbasedUitW5-year data plan) wherethereis adequate celiala:serviceirtheinstallationarea.) Con s,:mpticn Monitoring CT Solit core c urrent transformers enable whole home consumption metering(+/-2.5%). Enphase The Enphase IQ Combiner 3- with Enphase CT-200-SPLIT / ) •consurrmton mm-2tw lanquired rorE xmt 5wrza*S.v r•n V / /� IQ Envoy' consolidates interconnection Wireless USE adapter Installed at theiQ Envoy.Forcomm:rnications whir Enphase fncharge"storage and Enphase Corn COI.!MS-KIT-01 Enpowerl smart switch.Includes USS E able for connection to IQ Envoy or Enphase V5 Combiner" 1 Cobi3 egUr���t>[into a 51€'91eenC1C5lrG and and allows redundant wireless communication witfiEncharge and Enpower. CI Circuit Breakers S.pports Eaton BR210.88215,BR220.ER230,BR240,BR250,and BR260 circuit.breakers. Li J (X-IQAMI-240-3 StreaBRK-10A-2-240 Circ.iit breaker.2 pole.10A.Eaton BR210 - ) rnlFnes PV and storage installations by BRK-15A:2.243 Circ itbreaker,2pole.l5A.EatonBR2".5 BRK 20A-2P-240 Circuit breaker,2 pale,20A,Eaton BR220 0 providing a consistent,pre wired so ution for EPLC-01 Power line carrier rc om munication bridge pains,quantity-one parr residential applications-It offers tip to four XA-PLUG-120-3 Accessary receptacle for Power LineCarrierinIQCarmbiner3(required for EPLC-01) 2-pole input c rcL is and Eaton BR ser-es XA-ENV-PCBA-3 Replacement IQ Envoy Printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS busbar assembly. Idling T Conuaus duty - System voltage 120./240 VAC.60 Hz O Eaton BR series busbar red rig 125 A Max.continuous current rating(autputto grid) 65A Max.fuse/circuit rating(output; 90 A IjJ Branch circuits(solar and/or storage) Up to four 2-vole Eaton BR series Cistributed Generation(DG)breakers only gnat included) Smart Max.contin;ioas current rating(input from F-Vi 64A I Max.total branch circuit breaker ratio_(input) 80A of distributed generative 1 g0A with IQ Envoy breaker',ncluded r • Includes IQ Envoy for oommunicat?on and control Productic n Metering CT 200 A solid care pre-histailed and wired to IQ Envoy l� Flexible networking supports Wi-Fr. MECHANICAL DATA Ir >! I Y Ethernet,or cellular Dimensions(WxHxD) 49 5 x 37.5 x 16.8 cm(19.5'x 14.7'5'x 6.63').Height is 21,06'(.53.9 cm with mounting brackets). z1_ 1' 11la a — } jjTS j Optional AC receptacle available for PLC Weight 7.5 kg(16.5 Ibs} SEAL ,t�■ E �i�� bridge Ambienttemoerature range -400 C to.460 C(-40oto 115°F) � 1 ' e E N ••.•G Provides production metering and optional ,�Q ,• \ Cooling Natural convection,plus heat shield consumption monitoring Enclosure environmental rating Outdoor.NRT1_certified.NEMA type 311,polycerborate constructicn :* Wire sizes • 23 Ato 50 A breaker inputs: 14 to 4 AWS copper conductors • 1 p 63Abreakerbranchinput: 4to1,0AWGcopperconductors . AS ;P Sim le Main lug combined a.ttp t 10 to 2!0 AWG copper conductors i TATE •f - Neutral and round: 14 to 110 co per conductors 11 Reduced s?ze from previous combiner gp ♦i A,»aysfollavr local coderequiretnentsforcendurtarsizir_g. (� 1 Centered mounting brackets support single Altitude To 2000 meters(6,560 feet1 �j /•'• ••••' ��� stud mounting Q�■,,SIGNATU ■ INTERNET CONNECTION OPTIONS Supports back and side conduit entry — — — — — ■._ _•�yL� Integrated Wi-Fl 802.11b1g?n?n • Up to four 2-po€e branch circuits for 240 VAC r Ethernet Optional,802.3.Cat5E(or Cat 6)1rTP Ethernet cabs=_ (Poi included) . , 1 plug-in breakers(not inc€uded) SPECIFICATIONS • • 80 Atotal PV or storage brands circuits Cellular Optional.CELLMODEM-91(30)or CELLMODEM-03 I;4Gt or CELLMODEk-Mi(413 based LTE-M) [Pat irtclsded) SHEETS COMPLIANCE Reliable Comoliance.Combine•; UL 1741, CAN!CSA C22.2 No.107.1,47 CFR.Fart 15,Class 8,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Compliance,10 Envoy UL 60601 i/CANC SA 22.2 No.61010-1 [ irable NRTL certified NEMA type 3R enclosure V DRAWN BY: B.C. F)ve-year limited warranty UL listed To learn more about Enphase offerings,visit enpisase.com REVIEWED BY: P.E.C. LISTED Sr 2''18 vi rrx rrrery}All;yl lnredvrI.ripiw;e,rit.ri A aselux..• ^CI-.r -3,ar.l ultw-r teienlartau ia'. i r,t-re•e the REVISIONS To learn more about Enphase offerings,visit eaphase.cocn EN PHASE. ice+ tll rr=rm, ri iy EN #H A E SPECS ■ Ds:a Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters INPUT DATA(DC) IQ7_-_6R-2-US/IQ7-60-B-US IQ7PLUS-72-2-US I IQ7PLUS-72-B-US Energy — T - Commonly used module pairings 235W-350W+ 235IN-4S0W+ Module compatibility 60-cell PV modules only 80-cell and 72-cell PV modules 0 Ii ti on S Direct Maximum input DC voltage £8 V 60 V Peak power tracking vai.age 27 V-37 V 27 V-45 V Operalicgrange 16V-48V 16V-60V W Min.-'M ax start voltage 22V/48V 22V/6^V Max DCshortircrit current(module isc, 15A 15A The high-powered smart grid-ready Overvoltageclass DC port II 11 Enphase Enphase lQ 7 Micro"and Enphase IQ 7-t ML r. ^' DC port backfeed cuuant 0 A 0 A 10 7 and 10 dramatically simplify the installation process while 7+ PV array calif g uratiort 1 x 1 ang ra;rnd ed array;No additional DC side protection required; (f) AC side protection requires max 20A per branch circuit achieving the highest system efficiency- OUTPUT DATA(AC) IQ 7 Microinverter iQ 7*Microinverter — Microint elf•}ar Peakoutputpower 250 VA 295 VA W �}/� 5..r 1 t Y�r[ 4 Part of the Enphase 10 System ,the[4 7 and Maximum continuous output power 2d3 VA 290 VA 10 7+Microinverters integrate with the Enphase Nominal(L-L)voltage;ranges 24D V 208 VI 240 V/ 208V/ 211-264 V 183-2229 V 211-254V 183-229V O IQ Envoy",Enphase I0 Battery-,and the Enphase Maximum continuous output current 1.0 A(240V) 1.15 M208 V) 1.21 A(240 V) 1.39 A(208 Vj n Enlighten monitoring and analysis software. Nor•inal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Ilz 10 Series Microinverters extend the reliaDiiity AC short circuitfaah current over 3 cycles 5.8 Arms 5.8 Arms standards set forth by previous generations and Maximum units per 20A(L-LI branch circuits 16(246 VAC) 1;3(208 VAC) 13(240 VAC) 11(208 VAC) Q Overvoltageclass AC port III ill indergo over a million hours of power-on testing. AC part backfeed current C A 0 A 0 enabling Enphase to provide an industry-leading Powerfactorsettir-g 1.0 1.0 warranty of Up to 2S years. Fewer factor(a iustablel 0.7 leadin ...0-71a in 0.7 leading...0.7la in EFFICIENCY @240 V @208 V @240 V @208 V PeakCEC efficiency 97.6% 97.6% 47.5 S 97.39 w CEC weighted efficiency 97.0 x 97.0 1 37.0 u 07.0 5. MECHANICAL DATA Ambient temperature range ,409C to+65nC I Relative humidity range 45 to 1005.(condensing) Easy₹o Install ConnectorFi•oe.IQ7-60-2-US&17PLUS-72-2-U33 MC4 nor Air phenci N4 UTX with additional Q-DCC-5 a 3apten Ccnr_ectortype(IQ7-60-B-US&1Q7PLUS-72-B-US) Friends FV2(MC4 intermateable). Lghiweiglrt and sirnp'e Adaptors for mod.Aes with MCA or UTX connectors: -FV2 to MCA:order ECA-S20 522 CD • Faster ins elation with improved,lighter two-wine cabling -FV2 to UTX:order ECA-523-525 Built-in rapid shutdown compliant(NEC 20149 2017) Dimensions Ch'xI-taDi 212 mr*x 175 mm x 30.2 mm Iwithaut bracket) SEAL Weight 1.08kg(2.381bs)- ♦♦♦♦♦Qc.�'` Productive and Reliable Cooling Natsralconvetticr-Nofans Approved for wet locations Yes Optimized for high powered 60-cal and 72-cells modules Pollution degree PD3 • More than a million hours of test ng Enclosure Class II double-insulated,corrosion resistant polymeric enclosure C * C rso:_ • Class II double-insulated enclosure Environmental category I UV exposure rating NEMA Tyne 61 outdoor O * FEATURES i .e_ ♦♦ UL listed Commtmicat'a, Power Line Comm unicaton(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. '/��j,S O'•• ��♦ Smart Grid Ready Both options require installation of an,Erphase iQ Envoy. SIGNATURE Disconnecting means The AC and DC connectors have been evaluated and approved by i!L for use as he load-break • Complies with advanced grid support,voltage and disconnect required by NEC 630. frequency ride-through requirements Compliance CA Rule 21(UL 1741-SA) Remotely updates to respond to changing UL 62109-1•UL1741/EEE1547.FCC Part 15 Class 8, ICES-0003 Class B, SPECIFICATION S grid requirements CANICSA-022.2 NC-137.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms.with NEC-2014 and SHEETS Configurable for varying grid profiles NEC-2017 section 630.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Meets CA Rule21(UL 1741-SA) _ and DC conductors,when installed according macufacturer's•instructions. Y! •The la 7*Micro is regrrred to sport 72-ce i nwurlet t.No enforced MAC tnGa.See the compelihi ty calculator ar lies Vtnphae-torn ifrwrt:'n nd rl ems,+nt:bt irv. 2.Nomina vo`tagle-ange can be eattnttd beyone nominal it required by the nullity. 3.Limits may very.Refer to local recu'aernents to derurethe nrsnbw of tnicratr:etteis per branch in you,area. DRAWN BY: B.C. ENPHAS E. To learn more about Enphase offerings,vi sit enphase.com EN PHASE. REVIEWED BY: P.E.C. To learn more about Enphase offerings,visit enphase•com a?L^78EneC: 4xr,yFL-r_t211JIlrLalr.runlet u ty of GarrawCr eryy,his. REVISIONS ` ,I^JlO�^ 73'.9-O5-79 J SPECS ROCK-IT s s er 3.O Energy Snow Load 0-210 psf SYsTem sPecFicaTionS Modules in, Landscape Wind 5Exposure 212 a Roof Pitch a 6:12 7-12<Roof Pitch<12:12 Max No of Panels 300 Modules per ground lug Materials 300 Series Stainless, W c, .A SCE_ -.v Category Lane! rte 2 eore c^ a one- 5000 Series Aluminum Max System Voltage 1000VDC Coating Black A ndodi=iorhaill Firdsb rfph 110 mph C 114 67 42 74 ClassAFireRating WthU11702Type1Rated LugSpecifications BumdyrCLS0-lTNGroundLug D °X 5d 36 01 74 74 Modules JUL Listing A1C)ER E9999) 3 140 do 54 90 rrph 115 rnph C 1'04 Si 38 98 80 80 Leveling Range 3}1" Ground Wine 14 AV s-4 AWGCopper D 88 51 32 83 68 68 Perabovvelugspec. Ground'Artre 13 123 72 45 95 95 Rock-h Slide Camp Range .3. Max Module Size N1.4ffl1[.Samm1x LL_i 100 rnph 125 qih C 88 51 32 83 68 68 Rock-h Slide Tile 4' 39.as;997mm)x 1`iamml D 74 43 27 70 57 57 5 98 57 36 93 76 76 Min/Max Roof slope 1.'2_-1241212 Max Downforce4Uplift Rating 45 PSF O 110 mph 140:no C 70 41 26 88 54 54 Max AnchorSpadng 135ment4Orm"i1 47 Rock-it Mount Load Rating .I 441hs wi?h Single S116`lag 3.0 D 22 56 46 46 Max AnchorSparng(32rnml 18` Safety Factor 8 15 -0 31 81 66 66 58 47 47 1213 mh 154 mph 38 Start Eox QTY 6 units Slide Fastenng Hole 541fi'd uttarater p C 61 22 p t 1 30 19' 49 40 411 Mount Box QTY 12 units Module Cantilever Maximum cantilever is 143 rx,I,3s Rock 4t Slide Box QTY 50 units bracket spacing ®t iacing Govemted by Sn w Load 1.)Valiret In abowXia repreee►rt t3e ma6nrnaflowaCle spacing In Indies for pmmta torces only on Exoaster;aiar ndorr. Coupling Box QTY 12 units Warranty 20 Year h4aterial and WosItrnan- (3 iroweverthe designer neat rotad iatr to meet apprrapda spacing sfuP Cl) 2.)ii SJn:rn alxrred spadag aped by EooFhetan So;a Is 72" 3.}r,4 fm an alma standW capdty-5:7R tpert rng reWt,% Codes National Electric Cede,ANSI/NFPA 70,NEC 250,NEC 690,1 RC,IC 4.)rr iJdee atrrLwional taco o safety of:.5 itr tsgptIhacEy 5.)Values tweed on a rr®Grr 01 ino .te Y+tdtr or 4d' Standards UL 2703:First Edition,UL 1703 W [.1 Based on Ftisk Category ri(ACE 7-la)S;iuc ire less 1113130 teet Ir,trek,1lt 7.)4{fl adp�btl2rc faraors an,6Es to 1. Jo alle speom eagtleering Is t'i<xa�ed Ira arts table "Per the UL2703 Standard:The system should be installed over a fire resistant roof ratted for the 8.1Th(s.cliartaWlesto oonptGlaon StergieInstaratons application.System components should be periodically re-inspected for loose components,loose I Snow Load d1-20 psf fasteners,and corrosion such that if found,the affected components are to be immediately replaced.• Wind Speed Exposure 2:12<Roof 4fitch 6:12 7:1 <Roof Pitdr<1212 ASCE 7-08 AS€ 7-10 Category Zane 1 Zone 2 Zone 3 Zone 1 Zoaie•2 Zone 3 4 s r 8 91 53 33 SEAL a ..•E•.. B5nph 110mp4i C 65 38 24 61 5a 511 FeaTUres O� � ••' c EN•'•:� �'• D 55 32 20 52 42 42 '���Qa'.%`, S f •G �. 8 33 49 311 • 90 mph 115 mph C 59 35 22 50 411 44 :* 7 D 50 29 18 47 3B 38 v New and improved design • North-Southadjustability C 70 41 26 64 544 Fastest,easiest to level system inn ttlemarket • Only one tool required(1 f7"dee,p wellsocket) = �: * •m 100 mptt 125 mph C' rat} 29 18 47 3c 33 f a w .O• ST O • E 42 26 15 411 sc 32 Integrated electrical bonding • Vertical adjustment of 3 -4 _ 41] 23 14 38 31 8 56 33 20 53 43 43 t SIMPLE-only 5 components s•• R a ��� 1 Omph 1�tlmplt DC 34 19 12 32 26 28 ,iONA•• s�� SIGNATURE S 49 2E 18 46 .' .•e 120mph 150 mph C 26 2L' 12 33 27 D 29 17 10 23 22 4 SPECIFICATIONS Spas 1g GDvemedtry Load 1.4 Vail d,awve tabre repreee.rtthe mdnexnal =e spc:rg in lncteeME pl1bt tomes only cn EeoFa&e1 Soiz stanticr SHEETS 2)M3rllmlfl ai1011+et,spa ing apps red by EooFaete, tar Is 4E` 3.)Mazyn.an slowed standoR capdtyr-57 ecteeXng resins} 4.) Iatidee adiftlonal factor of safety or l. tor 139 pt.Esut capacry 5.)Values based on a n Enatrn rvwe Jengpi of 7 D fi.)Eased on fast Category+H(ASCE 7-1a)ximchfes ess*.113130 feet In bek3lt 7.)AV ad):>strtten:Tae to are sM to 1.Nos 1e sperm enj;-ieW Ins trrd�Ir VU tat e DRAWN BY: B.C. 8.}Ills man applies oo toar'poebton Shingle mdaraltono REVIEWED BY: P.E.C. REVISIONS www.ecofastensolarcom info@ecofastensolar,com 877-859-3947 8 www,ecofastensolarcom info@ecofastensolar.com 877-859-3947 2(1 SPECS ■ Grc�unainG In c.�r rT��T �n THErr al- Expansion and BOnDIfG Energy Therail-fteeRock-ItSysternmaybeusedto mountandground PVmodt iesthatcomplywithUL 1703,only whenthatspecific modulehas been a;-aluated for mauntingand grounding,in compliance with the included installation instructions. A thermal expansion gap is required per SIt tl Park each continuous 44 length of modules. � Note.GroundingIugmustbevisibletoinspectorsfromtheentireperimetecafthePVarray. ail GmL-ndinrLug Omit a coupling and leave a 2 gap in ( ) Aitulti UseGroundin Pinsr'- i a" `f ck'"R > P'� 9the Rock-It Array Skirt and also between the modules at that Dint �',`.�It (_J__)Grounding pinswithintheMidClam.paremultipieusebonding/groundingdeviees Moduleswwillneedtobeadjustedift e P Rork-It Loilpt.ng I� MidClarnpsare loosenedtoensurethereis'neW rnetaitopierceintouponretightening. U kook lth9ounl w Gro unding Method —Rock•Ir Array ski ri C) Rock-It3.0MountbondsN-Srowsofmodules BraCKeT SPc CIr1G Rock-It 3.0 Coupling bonds E-Wrowwsofmodules Portrait Orientation Landscape Orientation Rock-It Array Skirt bonds E-W along the entire array when installed r T T f One approved ground lug is required per PV array,limited to 300 modules placed in either portrait or landscape orieritatiorL O C!) BOnDinG AssemSLY ant eonDinG PATH R�,o�lti r -. Gi.KdnxA:rr. I I- Integrated Bonding Maximum east/west bracket spacing is 4$"OC. Max east/west bracket spacing is 72"0C. SEAL o Hoc,►t4uv,"g _ _ - 32mm modules:Max east/west bracket spacing is4V0C. ��•gw••••••••••••o,p�i�� Spacing may vary dependir►g upon protect spedicstructural requx�textts,i.e.high snowandwind load Q ' -.,k.e ..ul areas may require lesser spacing E-W than the maximum. * No 62 ;, Rodr-tt,r.odoWdic�ema$are atnn sTaGGereD Lc POUT GanTILever ante OFFSET iY7 * Staggered Mounting Points : �,• 5 �: 1 _ SIGNATURE Lm"y�rt 8xd NJ— / 4:.:.-yuJrK t►� �t:ur tgr,1.,K+r=�,Im�r = ■ >. ISPECIFICATIONS u%eh b tr+i• . n S v �bvrv. - -- SHEETS a7.t.[[mtr_rq � axt r r.r•%Ik�A—,. kn s.Gz M-•h I I .I tk-Ft riAaun# tick-lrCaupl�t9 Can tilever_Nlaximumcantileves is 113 bradset sparing.For portrait orientation L nat;ors,check layout toinstalling. DRAWN B Y: B.C. The array layout instructbns in this installation manual offer a general overview of Layout Periodically,due to a vadiety of Offset Offset from an roof edges depends on wind speed,snow REVIEWED BY P.E.C. factors{roof obstacles,shadaig,etc.)other layouts are requited. loads,local fire and buil&ng codes per location www.ecofastensolar.com inf4@eeofastensolar.com 877-859-3947 18 wwww.ecofastensolar.com info@ecofastensolar.com 877-859-3947 19 REVISIONS SPECS ■ RSTC Enterprises, Inc. Energy 2 � Heirstead load Eau Claire, WI 54703 4 L A D E K 715-830-9997 FLASHED PV ROOF-MOUNT OOMBINERI(NCLOSURES i-- U) Outdoor Photovoltaic Enclosures 0799 Series cC Cornpositicn!FCedar Roof System lz w ETL listed and labeled O Report#3171411 PRT-UI Revised May. 201 8 • UL50 Type 3R, 11 Edition Electrical equipment enclosures __ • CSA 022.2 No.290 Nema Type 3R • Conforms to UL 1741 Standard ' i' U) 0799 Series Includes: 0799-2 Wire size 210-14 L-LJ 0799-5 Wire size 14 0799-D W ire size 14-8 r Models available in Grey,Blank or Stainless.Steel CD SEAL E III Basic Specifications -. - ,oa°......•, Material options: I - _ *?• Igo 62 ••* • P ider coated, 1&gauge galvanized 90 steel 5 * E (1,140 hours salt spray) •' ■ Stainless steel %o•• A� ''•W � Process-Seamless draw(stamped) III,1ONA �tSIGNATURE Flashing- 15-25'x 1725 Height-3' Cavity-255 Cubic inches SPECIFICATIONS SHEETS Base Plate: • Fastened to base using toggle fastening system • 5 roof deck knockouts -- • Knockoxtsizes: (3)-5', (1')_75aand(1) 1" DRAWN BY: B.C. • 8",35mm skrtted din rail REVIEWED BY: P.E.C. • Ground Block REVISIONS Passlhrough and combiner kits are available for either - 4 :: AC or DC applications- SPECS ■ 6.63; -S2 IA WIRING DIAGRAMS Energy 16 1 e8 DIA FUSIBLE oft tions Direct __ .153: BU TERMINAL LUGS AMPERES MAX. WIRE M]N. WIRE TYPE 14.88 1 1 24 60 #3 AWG #14 AWG CU OR AL 37t3 ₹85 � Kv K .GT5 rU SYMBOL CONDUIT SIZE DIAMETER J I N MM IN MM KNSCKOTS A,B,C A .'5O 13 .88 22 KNOCKOUTS B .75 19 1.13 29 C 1.00 7 25 1.36 36 LEI D 1.25 32 1.75 45__________ /11 .64 42 3.78 4.87 9G 124 31 DIA — S 7.45 SEAL ..... • (2 HOLES) 1BB O�,OQ�O• E : ••C NEMA TYPE 3R ? 9• -` * ST OF w z KNOCKOUTS .. _A ,� • o• �. KNOCKOUTS ., .a'• .... '��. [3 AL O]N1EN514N5I I3�iCHES '*"'oIdA SIGNATURE me1LLIPETER3 .28 DIA KNOCKOUT A,B,C HORSEPOWER RATINGS VOLTAGE RATl SPECIFICATIONS 7 Kt OCKOUTS 240VA� CATALO' 0. 5 11[R[ "3 AMPERE NOTES, NUMBER DIA', RATING STD MAX SHEETS FINISH — GRAY BAKED ENAMEL ELECTRODEPOS[TEO OVER CLEANED PHOSPHATIZED STEEL , UL L15:TEaD — FILE E-2875 1 3 0 1 , _30 ALL NEUTRALS — INSULATED GROUNDABLE 51ITABLE FOR U5E A5 SERVICE EOU[PMENT D222NRB 24OVAC A 60 3 _30_10 .SV ID 1S! SHORT CIRCUIT RATINGS. D322NR9 240VAC 8 60 'IE 7.50 10 15 10,00;2 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K F(5E5 DRAWN BY: B.C. 100,E AMPERES WHEN USED WITH OR PROTECTED BY CLASS R FU5E5 REVIEWED BY: P.E.C. TOP ON NEMA 3R ENCLOSURES HAVE PROVISIONS FO R MAXIMIt'1 2.50 BOLT-ON HUBS. WHEN MOUNTING THESE SNITCHES, ALLOW 3.00 IN / 76 MM MIN. CLEARANCE BETWEEN ENCLOSURES FOR OPENINS OF 5IOE HINGED DOOR. GENERAL DUTY SAFETY SW ITCHES - REVISIONS * 5E OUT SWITCHING POLES VISIBLE BLADE TYPE ® �� � ■F0 CC NER GROUNDED DELTA SYSTEMS ONLY. E. AMPERE $L1 5 SUITABLE FOR 60•C OR 75•C CONDUCTORS. ENCLOSURE — NEFA TYPE 3R RAINPROOF 1 863 JUNE 2000 REF GNG s1B53 SPECS