Loading...
HomeMy WebLinkAbout20-898 a City of Zephyrhills PERMIT NUMBER 5335 Eighth Street zephyrhills, FL 33542 BGC-000898-2020 Phone: (813)780-0020 tr Fax: (813)780-0021 Issue Date: 10/14/2020 Permit Type: Building General (Commercial) Property Number Street Address 13 26 210140 00000 0080 1Mis See Description 13 26 21 0140 00000 0080 Owner Information Permit Information C.o.ntrac#or Information Name: Permit Type:Building General(Commercial) Contractor: CHARTER COMMUNICATIO Class of Work:Right of Way Temporary Use Address: Building Valuation:$1.00 Electrical Valuation:$1.00 r- Phone: Mechanical Valuation:$1.00 Plumbing Valuation:$1.00 1 Total Valuation:$4.00 Total Fees: Amount Paid: Date Paid: Project Description ROW 39756 MEADOWOOD LP-FEE WAIVED Application Fees REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONT C R SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER L� / �nTO —A CITY OF ZEPHYRHILLS-BUILDING DEPARTMENT DATE: f— �" RIGHT-OF-WAY USE PERMIT PERMIT# No construction under ground or above ground of any facility shall be accomplished on any City Rights of Way without written approval from the City Building Department.Any application for approval of construction operations on any City owned Rights of Way shall furnish a detailed drawing showing the complete scope of the proposed work in triplicate to the office of the Building Official for approval prior to the commencement of any work.A copy of this permit is to be kept readily available at the site of the work at all times. - PARCEL I.D.H 13-26-21-0140-00000-0080 CITY ROAD Meadowood Loop DATE I2O LOCATION(Legal Description): 39756 Meadowood Loop,See attached legal description Permission is hereby granted to Spectrum Sunshine State LLC of 30432 SR-54 WESLEY CHAPEL,FL 33543 for the construction and maintenance of- Replacement 60ft of existing cats conduit&cable within road right of way _subject to the following conditions: 1. The construction and maintenance of such utility shall not interfere with the property and rights of a prior occupant. 2. All work shall be done in keeping with the standards of the City Streets Department and under the supervision of the City Building Official,who will be notified at least one day prior to commencement of construction. 3. All materials and equipment shall be subject to inspection by the City Building Official. 4. During construction all safety regulations of the Department of Transportation shall be observed and the City shall be relieved of all responsibility from damage of any nature arising from this permit.Subject to the same terms and conditions,the permit holder may take such safety measures,including placing and display of caution signs,as it may deem necessary in conduct of construction and maintenance work hereunder.It is the responsibility of the permittee to???? 5. All private and all City properly shall be restored to its original condition as far as practical in the opinion of the City Building Official. 6. All underground crossing installations shall be laid at such depth as maybe specified by the City Building Official. 7. The sketch covering the details of this installation shall be made apart of this permit.This permit is granted with the understanding that the applicant has notified all other utility users in the area covered by the permit and takes full responsibility for any damage incurred by prior installations as a result of his operations in order that they may safe guard their interests. 8. It is expressly stipulated that this permit is a license for permissive use only and that the placing of facilities upon public property pursuant to this permit shall not operate to create or to vest any property right in said holder. 9. Whenever the City decides to further exploit the City Rights of Way,any or all said poles,wires,pipes,cables,or other facilities and appurtenances authorized hereunder,shall be immediately removed from said Rights of Way,or reset or relocated thereon as required by the City Building Official at the expense of the holder of this permit. 10.The holder shall save and keep the City harmless from any and all damages,claims,or injuries that may occur by reason of the construction, maintenance,and operation of said facility. 11.The holder shall complete the requested work within days or this permit shall become null and void.In the event the work requested is not completed upon the expiration date of this permit,the City shall have the right to complete such work and to charge the holder of the permit for all costs incurred in completing said work. 12.The holder shall post a cash or surety bond with the City Manager in the sum of S dollars to guarantee performance of the obligations herein,and to guarantee maintenance of the right-of-way described herein for a period of one(1)year following completion of the requested installation.In the event a surety bond is posted,the surety bond shall be made payable to the City and shall obligate the surety to hold the City harmless in the event the holder of this permit should fail to meet any of its obligations hereunder.The bond shall also indemnify the City for all court costs and reasonable attorneys fees in the event legal action is required to collect on said bond. SUB TTED BY: (Permittee) 2_ clnrd U V J i Signature&Title 1, 14 per^ �V �f�R�0-1/ 1L 1 �3SI'I APPROVED BY: CITY OF ZEPHYRHILLS Building Official Date: Utilities Supervisor Date: Public Works Date: City Manager Date: JOB LOCATION MAP General Note5 _----_i_-_-_-._---^-_..--__-,____.---___-__._..__ ,,_ ,•_. .. I,Alatv Construction wlkhl the Public plghb of Way shall be In conformity I n 'Z'E P H Y R'H I L L',S` w6 the Local Jurisdiction's"Minimum Standards" M U-N C -I.P''-A 1, Per FP01 Standard flans and Standard 5pecifications for Road and AI:R:PORT'tt i N'D';U S`T'R I A`L`, Bridge Construction Standard Plan#522-001, >P A iR K E A S•Tkl� 2,1 Io Contractor shall notify Call Sunshine and other utilities prior to � Z'E+PHY.R P:I;N;E`S I ' I; 9-ReadyR'fresh by,N.e5116& 1t commencement of construction, '_``'�;ro._4 '',,.Skydipe-Ciry2-Hi11s,'v1j_ v 3•Use the"Pirectlonal l3ore Method"for all driveway crossings, 4.Al p p = Gunner ._® it` open as halt cuts shall be restored as er exhibit F of the 5 fpaw park='�•1_.,... •- _ F,17,0,1,utllk accommodation quide, `YJ 0'0 D'L A N.D 5.Al side walk removal and replacement shall be restored to =..k.0 R ES' M!E;A D aw O O D the Local Juri5diction's and F.12.0,f,Standard 5pecification No,522-001 Wheelblast In: i E S T AIT Eat ,j ,, within�2 liars of removal, sol1THEASTERN- :-. ij i i 6.Al aerial construction shall maintain a minimum of 18'clearance parallel to a_ ' :_, - ` ' Sunrise Manufacturing -.i=-" -- and crossinq all F•17,0•f,Pighth of Way, 1,Al aerial construction shall maintain a minimum of 18' clearance parallel to C O MaL1 U'Ni Y ;?'?_ -, Mapdsta620 G60iiia and 18 ' crossinq all Canty and Municipalities fights of Way, 8,Must maintain minimum 2ft seperation between existing utilities weather goinq over or under or paralleling, 9.Physical hand digginq to be used at all times in conflict zones to minimize damages, 10.Underground utilities have been plotted from availble records and field o6ervation5,but are not necessarily exact,Therefore utility locations will be verified IOOft In advance of trenching,plowinq and 6orinq, so that changes can be made In event of conflict, 11,f estoraUon shall 6egin within three(3) weeks after the installation of cable/conduit.Full grass by seed and mulch or soddlnq as approved, 12,No open trenches to be left open overnight,Needs to be backfllled UTILITY LEGEND or covered,(Public Safety Hazzard.) x PWR WOOD POLE — - - - - — ROW 13,No excavation shall be permitted within 10'of protected trees Epp (20'for Grand Oaks),Al utility installation shall be placed by directional bore © PWR CONCRETE POLE —-—-—-—-—-—-— CENTER LINE 6eginirq outhide of protected radius. LS] PWR STEEL POLE —- —- —- —- — POWER 14,These drawings are for permitting purposes only not construction plans, ST LITE �� COMM 15,All Construction Methods and Materials within FDOf ® JOINT USE TRANS —' —' —` — TELEVISION V W shall comply with the Latest Editions of the MIX ® JOINT USE —- —- —- —- — WATER Standard Plans,the Standard Specifications for Road&6ridge e FIRE HYDRANT — - - - - : _"Jci Construction and the Utility Accommodation Manual(UAM) �-� CULVERT -------------- RECLAIM 16,Al areas within FI70(V W disturbed 64 construction STORM DRAIN --------------- GAS shall be re-graded and sodded with Ilkc-kind sod, APPLICATION CITY OF ZEPHYRHIILS PERMIT- PROJECT NAME:30756 MEADOWOOD LP,ZEPHYRHILLS•FL COUNTY:PASCO N DATE:10-5-20 SECTION:13 TOWNSHIP:2r,RANGE:21 Spectrum► ® TO PLACE NEW CONDUIT&CABLE WITHIN CITY RIGHT OF WAY E ENGINEER:DARLENE HARMAN DRAWN BV:K.L. W JOB DESCRIPTION: PRISM NUMBER:2480237 NTP N: SCALE:NONE s CATV UNDERGROUND CONSTRUCTION TYPE OF PERMIT:CITY TRACKING k: DRAWING SHEET:1 OF 3 PLANVIEW OF CATV UNDERGROUND CONSTRUCTION Note: Maintain minimum 30" from storm structures � µ ED r S (cod w M a of Begin construction at Row Proposed placement of 3 ` 60ft Catv Cables & (1) 2" HDPE Innerduct °o C \ P fifi dw t�\ Directional Bare Minimum 48" depth Refer to Directional Bore Profile A 0 2 gras EoP 6L MEADOWOOD LOOP � Eop - 2 Y grass 3 � \, Row •----- _ \'\ 20' \ dw �--� End construction at Row ` n PO a, OtVL PROJECT NAME:39756 MEADOWOOD LP,ZEPHYRHILLS,FL COUNTY:PASCO N APPLICATION CITY OF ZEPHYRHIILS PERMIT DATE:10-8-20 SECTION:13 TOWNSHIP:26 RANGE:21 Spectrum► , ® TO PLACE NEW CONDUIT&CABLE WITHIN CITY RIGHT OF WAY ® w E ENGINEER:DARLENE HARMAN DRAWN BY:K.L. s JOB DESCRIPTION. PRISM NUMBER:24811237 NTP 4: SCALE:1"=50' CATV UNDERGROUND CONSTRUCTION TYPE OF PERMIT.CITY ITRACKINGM DRAWING SHEET:2 OF 3 PROFILE VIEW OF CATV UNDERGROUND CONSTRUCTION PROFILE A TYPICAL CATV DIRECTIONAL BORE CROSSING ROAD ROW MEADOWOOD LOOP LOOKING WEST Row 60' Row 20' op 10' C/L 10• Eop 20' I i � grade ------- I grade I � � 24"----- ------------------- --------------`-------------- ----------------- 24" End construction at Begin construction Row30 -----I-------------------- ----30:-------1-----30.------- --------------------!-----30^ at Row I 2' , Z�36 ------------- 0 -------------- -------------- - - '-Z 3wFr--- .I / 3/6" - --- ----= ---- 48"------------ ------------ ----------- - ------ - ---- 48" 60"-----1-----------------------------------I ------------- --------------------1-----60" i T i 72" T-------------------- --i-------------- T-----72" I i I Proposed placement of STANDARD TRENCH DETAIL 60ft Catv Cables & (1) 2" HDPE Innerduct Directional Bore Minimum 48" depth rnsnru win rM'N' uu w T ro E. 1 Mi 36MIN. . 38' TO rtuwm a,c TO TT-1m E 5• Z• 5• PXOPOSm CA /MR/SwmUIE 40-T NOTE: ALL EXISTING UTILITY DEPTHS & LOCATIONS BASED ON A $ STANDARD, AVAILABLE RECORDS AND FIELD OBSERVATIONS. s� WILL REQUIRE UNDERGROUND LOCATES PRIOR TO CONSTRUCTION. 2 A MINIMUM OF 24" VERTICAL AND 24" HORIZONTAL SEPARATION FROM EXISTING UTILITIES MUST BE OBSERVED. W-T w�TOscsuv[o Hsxu vu® TO umx ury unua�xo A MINIMUM OF 18" VERTICAL AND 36" HORIZONTAL SEPARATION sacs uATww ro semx rove/soars w eoxwn a s-ISTs FROM EXISTING GAS MAINS MUST BE OBSERVED. PROJECT NAME:39756 MEADOWOOD LP,ZEPHYRHILLS,FL COUNTY:PASCO • ® N APPLICATION CITY OF ZEPHYRHIILS PERMIT DATE:10-8-20 SECTION:13 TOWNSHIP:26 RANGE:21 Spectrum► 1 ® TO PLACE NEW CONDUIT&CABLE WITHIN CITY RIGHT OF WAY s W E ENGINEER:DARLENE HARMAN DRAWN BY:KL. JOB DESCRIPTION: PRISM NUMBER:2480237 NTP N: SCALE:NONE S CATV UNDERGROUND CONSTRUCTION TYPE OF PERMIT*CITY I• TRACKING N: DRAWING SHEET:30F3 ROAD WORK END AHEAD ROAD WORK A ■ ■ ■ ■ B ■Taper Length=%L Work Area See Table 11 END Table 11 ROAD ROAD woRK Taper Length - Shoulder WORK Oevlce Spacing-Taper Device Spacing-Tangent SOO See Table I See Table! Y,L(f[) AHEAD SPEEDING FINES Speed Notes DDuaLED (mph) 8' 10' IY WHEN■DRKERS Shldr. Shldr. Shldr. PRESENT 25 28 35 42 Table 1 30 40 50 60 LewSr Device Spacing 35 55 68 82 60 Max.Distance Between Devices(ft.) 40 72 90 107 Speed Cones or Type I or Type 11 45 120 150 180 DISTANCE BETWEEN SIGNS (mph) Tubular Markers Barricades or Vertical Panels or Orums 50 733 167 200 Speed Spacing(ft.) Taper Tangent Taper Tangent 55 147 183 220 A 1 B 25 25 50 25 50 60 160 200 240 L=WS 40 mph or less 200 200 30 to 45 25 50 30 50 65 173 Z17 260 45 mph 350 350 50[0 70 25 50 50 100 70 107 233 280 50 mph or greater 500 500 `Midway between signs. 8' minimum shoulder width VIL= Length of shoulder taper in feet SYMBOLS GENERAL NOTES DURATION NOTES W- Width of total shoulder in feet (combined paved and unpaved width) ® work Area 1.When four or more work vehicles enter the through traffic lanes In a one hour 1.Signs and channellzing devices may be omitted If all o/the period or less(excluding establishing and terminating the work area),the advanced following conditions are met: 5= Posted speed limit(mph) FLAG GER sign shall be substituted for the WORKERS sign.For location of(laggers a.Work operations are 60 minutes or less. ■ Channelizing Device(See Index 102-600) and FLAGGER signs,see Index 102-603. b.Vehicles in the work area have high-intensity,rotating, (lashing,oscillating,or strobe lights operating. [p Work Zone Sign 2.SHOULDER WORK sign may be used as an alternate/o the WORKER symbol sign only on the side where the shoulder work is being performed. b Lane Identification+Direction of Traffic 3.When a side road intersects the highway within the TTC zone,additional TTC devices shall be placed in accordance with other applicable TCZ Indexes. 4.For general TC2 requirements and additional Information,refer to Index 102-600. CONDITIONS WHERE ANY VEHICLE,EQUIPMENT, WORKERS OR THEIR ACTIVITIES ENCROACH THE AREA CLOSER THAN 15'BUT NOT CLOSER THAN Y TO THE EDGE OF TRAVEL WAY. R LAST J;Z�DESCRIPTION: FY I020-21 x REVISION u, FDOT TWO-I,tINE, TWO-WASH, WORK ON SI:IOULA�IZ INDEX SHEET 71/01/17 r� STANDARD PLANS 102-602 1 of 1