Loading...
HomeMy WebLinkAbout20-899 -' City of Zephyrhills PER � � MIT NI�IMIIIIIII UMBrER { 5335 Eighth Street Zephyrhills, FL 33542 FIRE-000899-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 10/21/2020 Permit Type: Fire -s?` az'.v>.• .,-•N r:-rr aa¢z „s' a. - r y;•.'^ rae+c-� n re �Propecty�Numtier� , a ':v'r �� ;� ' _ St',eet,Address ,� 1126 210010 18500 0030 15131 Gall Boulevard Permit Info tion= Contractor Information - Name: CORTES CORTES INC Permit Type:Fire Contractor: STATE FIRE PROTECTION Class of Work:Commercial Kitchen Exhaust F INC Address: 7518 Arms Dr Building Valuation:$2,365.00 ZEPHYRHILLS,FL 33540 Electrical Valuation: Phone: Mechanical Valuation: / Plumbing Valuation: Total Valuation:$2,365.00 Total Fees:$130.00 Amount Paid:$130.00 Date Paid:10/21/2020 11:19:24AM 21 Prolect�Description �. , ,•. INSTALLATION SUPPRESSION pA plicationFees. Hood/Ducts Permit Fee $50.00 Suppression System Plan Review $50.00 Fire Suppression Inspection $30.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACT R SIGNATURE PE IT OFFICE PERWI EX IRES IN 6 MONTHS WITHOUT APPROVED INSPECTION C�4 L FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Fire Fax-813-780-0021 Permit Application Date Received Phone Contact for Permit 7 &Cqt P7 14 9-� Owners Name LR. Ma-r- Owners Phone Number E= Owner's Address I t .61 V r-> Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address Job Address t COA-11 R) I V D Lot# Sub Division Parcel# .RI M,RRO RERTZATMi 140010 E-*wm w F-1 Blo-Hazard Waste Storage-ANNUAL Fumigation Tent Mr"r73 Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier 11 or RO Facility)ANNUAL Controlled Bum Hood Installation F-1 Emergency Generator<30 kw LP/Natural Gas-Installatior 0 Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale 0 Fire Protection Maintenance-ANNUAL o Places of Assembly-ANNUAL M-Fryl Semi rA-n-ll Other-j Sprinkler F-1 0 0 0 Recreational Bum Fire Alarm F-1 0 0 0 El Sparklers Hood Cleaning 13 0 0 0 Sprinkler System Installations Hood Suppression 0 0 D F—] Standpipes(Sprinkler Sys) F-1 Fire Alarm Installation Torch Roofing/Tar Kettle F-1 Fire Pumps Waste Tire Storage ANNUAL RFlammable Application-ANNUAL Fuel Tanks F--j Other: r— Contracto ompany '�1,44F Signature YrN,,] Fee Current L Y/NJ-` Address License# ELECTRICIANI Company Signature Registered Y/N Fee Current Address License# PLUMBER Company Signature Registered Y/N Fee Current Y--/—NT— Address License# MECHANICALI Company Signature Registered Y/N Fee Current Y/N Address License# OTHER Company Signature Registered Y/N Fee Current —Y Address License# Directions: Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" •which may,be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: : N the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for.the intended work, they are advised to contact the Pasco County Building Inspection Division--Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractors) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW.(Chapter 793,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, i certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", i certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application Is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions 1 must take to be in compliance. If I am the AGENT FOR THE OWNER, i promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter,or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. if work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. iF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) !_. OWNER OR AGENT CONTRACTOR'�f� � Subscribed and sworn to(or affirmed)before me this Subsetibed,and swom to(or affirmed)bef a me this by by 1 Who-Is/are personally known to me or has/have produced Who islare personally known t e or has ave produced As Identification. as Identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped L' �•rrrri�rrr•�u.rr��rr.r �� r rrrra�rr: rr..�r.ri.�. ..-. .. ..- --_.. 1AIOi3IC SFIALL.COMPLY WITH _ ____-_ NEEA CODES AND STANDARDS (4�v - 4-soTO - - i o Ve. REIIIEIN Ctl'Y Of ZI=PHYRtiILLS - F1I SAND Llff SAFM EXWINE- - _.. .. .: _ 1j system-to tie Pyro Model. NO, t3tpe ' - . 2). Ail' fuel -wd elecUic uoldg bwd to- dUt &M up= -t')ie bWP 9) RwoU manual pull -statica to-.be cm parch of-eg me 40" .max. A,?: . _ _ 4) �ullw iwp rlo�le e3eoate fuse 3.3uk houarirg G) Chess " '. UL `ratsd.:fiace .extin+gu3,a to be in kitten 7) 949teon utilizgs`-q-Qf_ � aavai.4AKO'fig FAuts - '� S K 9"it wTIO a LJ I 1 l '3 2. a A) P,diC0 A Z*A)c od f',4 ")r PG �ir�te;Lt A r-f*. Q4 W t4"• _ PYRO-CHEM® �Q�: KITCHEN KNIGHT6 11 KITCHEN �7 PIPE VOLUMES,: KNIGHT II: Chem CONVERSION CHART ► 1/4 in.=20.5 ml:per ft 3/8 in.=37.5 ml per It 1/2 In.=59.8 ml per ft 3/4 in.=105 ml per it• . Total 1st Nozzle - Total Pipe Maximum Pipe Length h'From 1st Nozzle to Last Nozzle Maximum Pipe Length Cylinder Flow Pipe to Last 1/4 in. 3/8 in. 1/2 In. 314 In. 114 in. 318 in. 112 in. 314 in. Size Pis Vol Nozzle ft- (m) ft (m) ft (m) It (m) It (m) 11 (m) It (m) It (m)- PCL 160 5 1500 600 73.1 (22.3) 40.0 .(122) 25.0 -(7-6) - 29.2 (8.9) 16.0 (4.9) 10.0 (3) ,.300_ - G1 l 1910 1125 93.2 (28.4) 50.9 (15.5) 31.9 (9.7) 18.2 (5.5). 54-.9 (16.7) 30.0 (9.1): 18.9 (5.7) 10.7 .(3.4): PCL A60 -. 14 3400 3000 165:9 (50.6) 90.7 (27.6) 56.9 (17.3)-,32.4 (9.9) . 146.3'(44.6) 80.0 (24A) 50.2 (15.S) 28.6 (8.7) PCL 460 15, 2600 2Q00 126.8-(38.7)- 69.3 �21,1)- 43.5. (13.3) -24.8 ~(7.6) .97.6 (29.1).. '53.3 (16.3) 33.4 (10.2) 19.1 (5.6) PCL 600 19 .4215 16881side 205:6-(62.7) 112.4_(3425) 70.5 (21.5) 40.1 (122) 82.3 .{25.1) '45.0 -(13.7) 28.2 (8.6) 16.1-_(4.9} PCL 600 20 3465 1312.5/side 1N.0.(51.5) .92.4 (28.1) 57.9 (17.6) 33.0 (10) . 64.0 (19.5) 35.0. (10.7) 22.0 (6,7) 12.5. (3.8)- Pipe Length Volume of Agent per Pipe Length/Size, Minimum Pipe-Volumes for a Fryer,Range;;and Wok it . (m) 1/4 in. 3/8 in. 1/2 in. 3/4 in, Cylinder Size' Eutire:System At or before appliance- 1 0.30 20.5 37.5 59.8 105- PCL 160 239 ml-1 Flow Pt 180 ml-1;Flow Pt . 2 0.61 41 75 119.6 210 PCL 300 306 m1.-4 Flow Pis.. 239 ml=2 Flow-Pts - 3 0.91 -61.5 112.5 179.4 315 °' PCL_460- - 660 ml-10 Flow Pis 180 ml=2 Flow Pis 4 1.22 82 150` 239.2' 420 PCL 600• 960 ml-14 Flow Pis : 120 ml-2 Flow Pis - 5 1.52 102.5 187.5 299- 525 6 1.83 123 .225 358.8 630. 7 2:13 143:5 262:5- '448:6• 735 8 2.44 164 300 478.4 840. 9 2.74 184:5- 337.5 538.2 945 10 3.05 205 375 - 598 . 1050 11 3.35 225.5 412.5.. 657.8 1155 12, 3.66 246 450 717.6 �1260 13, 3.96 266.5" 487.5 777.4 1365 27,14 i 4 - 287.. 525 837.2 1470 15 4.57 . 307.5 562.5 - . 897 1575 16 4:88 328 600 956.8 '1680 17~ 5:18 348.5 - 631.5 1016.E- 1785 18 5:49 369 675 1076.4 1890 „ 19 5.80 389.5 - 712.5 . 1136.2 1995 - 20 (6.10) 410 750 1196 ' 2100 'General Rules: 1. Measurements taken from fittings centerline(A1l SCH.40 Pipe)_ . ► 2. Maximum difference in elevation from valve outlet to any nozzle is 10,ft(3.05 m). &-Largest diameter pipe must be used first and decrease in size as installation moves away from the tank. 4. No traps=in the piping. 5. Two elbows are allowed in place of a swivel:Elbows used as a swivel do not have to be subtracted from the total allowed..- -: 6. Maximum of 25 elbows., 7- Maximum of 5 elbows between nozzle and preceding tee. 8. Maximum.flows for 1/4 in,pipe=6 flows. . 9, Max'smum volume allowed for 1/4 in.-pipe from.tee to nozzle'is 410 ml(20 ft or 6.10-m). Additlonal rules for PCL 600: 1. Split piping must be used wWa maximum of 14 flows on a side. 2. No nozzles.before the split. 3:-Minimum 1/2 in.pipe must.be.used to the first split. �r j Jimmy patronis casin Sinco CHIEF FINANCIAL OFFICER BUREAU CHIEF Julius Halas DIVISION DIRECTOR Keith McCarthy SAFETY PROGRAM MANAGER 1,-OWS FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF STATE FIRE MARSHAL 200 East Gaines Street -Tallahassee,Florida 32399-0342 Tel.850-413-3644 Fax.850-410-2467 FIRE EQUIPMENT DEALER LICENSE OFFICIAL COPY THIS CERTIFIES THAT: State FIRE PROTECTION Inc. 1744 12th Street SE,#3 Largo FL 33771 QUALIFIER: Theodore J Macejak Has Complied with Florida statutes and has qualified for the type and class shown here on to service, repair, install or inspect all types Pre-Engineered Fire Extinguishing Systems.Excludes any service, recharge,repair, installation or inspection of any type of Halon System. Issue Date: 01/01/2020 07 a. Nass: 04 County: Pinellas License/Permit#: 028234-0003-1987 ;Expiration Date: 12/31/2021 Chief Financial Officer i ZEPHYRHILLS- FIRE DEPARTMENT 38410 6th Ave Zephyrhills,'FL 33542 FIRE=:SERVICE USER FEES increase 1/1/2018 Occupancy.No.: Plan No.: Contractor: _S/:41E' r ..cc' ?Ro1F�' Business Name: ,os,N M e Al-,GcC + Billing Address: Business Address:- 5 1 3 1 rA:i jV_Y,0 ?g5 Zoe �--s rY l.AQgo Business,Phone.No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact:' Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE .Annual- Education,healthcare,De tentionBCorrectional Public Assembly,Business, schools, Storage,Mercantile and -Churches Site Plan N/C Industrial. no charge Sprinkler $50 'Multi-Family/Commercial .03 sf- up.to 800 sq ft $ 24.00. Standpipes $50 (Minimum.Charge$24.00 801-1,500 sq ft $ 34.52 Fire Pump $50 'Plan Revisions DBL. 1,1,501-2,500 sq ft $ 60.02 Hoods $50 2,501-3,500 sq ft $ 90.02 Fire Alarm $50 SPRINKLER SYSTEMS 3,501-5,000 sq ft $ 127.52 LP Gas $50 0-25 Heads $501115,001-20,000 5;501-7,500 sq ft $ .187.52 Natural Gas $50 B26.plus Heads $100 ;7,501-10;000 sq ft $ 262.52 Fuel Tanks- per tank $50 .STANDPIPE.SYSTEM �10.001-15,000 sq ft $ 375.02 Sparklers $100 2.Per Riser $50 sq ft $ 525.02 Fire'Works $500 FIRE'PUMP 20,001-30,000 sq ft $ 750.02 Camp Fire(recreation; $25 1:Per,Pump $100 - 30,001-40,000 sq ft $ 1,050.02 Controlled.Bum(15da: $100 FIRE:ALARM SYSTEM 140,001=60,000 sq ft $ 1,500.02 Hood/Duct $50 0-25-Devices $50 i60,001=80,000 sq ft $ 2.100.02 Place of Assembly $50 Annual 80,001-($2,100.02)per 26.plus;Devices $100 . "ea add 1,000sq ft $ 0.06 Fire Protection $25 SUPPRESSION'SYSTEMS. : (Businewdlosed:until Flammable Application $50 Annual Wet $50 ;violations corrected) Waste Tire-Storage $50 Annual Dry $50 '.SPRINKLER SYSTEMS Generator<KW $100 CO2 $50. 6;Hydro Undergrounds $45 . Generator>30 KW $100 Other -$50' �,`HOrostaticTest $65 per system Bio-Hazard Waste $100 Annual KITCHEN-EXHAUSTAcceptance Test $45 per system Fumigation Tenting $50 Hood/Ducts $50 'Hydrant,Flow $75 Torch.Pot/Applied $50 .OTHER Haz.Materials $50 Annual LP Installation,per tank $50 FIRE ALARM SYSTEM Fuel Tank Installation .$50-8ElSystem-Acceptance $50 (PerTankj $50 'Recall Acceptance $50 a-Natural:Gas Installation $50 OTHER (Per p Systerrl) `:Fire WalUSmoke Wall $15 per wall Spray.Booth $50 'LP-Gas $25 per lank Watural Gas $25 per system Tent.10'x10'or greater $15 per tent ':Fire Pump $45 fire Suppression $30 ;System Acceptance :Exhaust Hood/Duct $30 Re-Inspection DBL .(other than annual) Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle Acce $50 PLANS:TOTAL 1-0 INSPECTION TOTAL O PERMIT TOTAL $-O GRAND TOTAL O Comments: Date: iy- , 9 - *1+Z- .:Inspector: see-back Alh .,.t y7!j","t,;i,•aq{^,.r,:,!:..sc" .Ott ":.:, n=^.+.^'r,SFSF•9's::x!t..RT..3tel:4'„Grit`k�'L'+LZe..:-r.�rro+:niN�7c