Loading...
HomeMy WebLinkAbout20-162 City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BGR-000162-2020 Phone: (813) 780-0020 �• Fax: (813) 780-0021 Issue Date: 05/27/2020 • Permit Type: Building General (Residential Property Number Street Address 14 26 21 0010 01900 0010 38640 A Avenue Owner Information Permit Information Contractor Information Name: BRIAN WILLIAMS Permit Type:Building General(Residential) Contractor:A BARTLETT ROOFING & Class of Work:Reroof CONSTRUCTION SERVICE Address: 38640 A Ave Total Valuation:$7,987.00 ZEPHYRHILLS,FL 33542 Total Fees:$79.94 Phone: (813)312-0957 Amount Paid:$79.94 Date Paid:5/27/2020 8:46:36AM Project Description REROOF SHINGLE W/2 SQ TPO Application Fees Building Permit Fee $79.94 1 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIR IN 6 ONTHS WITHOUT APPROVED INSPECTION CALL F NSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER City of Zephyrhiiis l 5335 81'St Zephyrhills FL 33542 j (813)780-0020 s, ROOFING INSPECTION AFFIDAVIT ` ..Perin I t — I, licensed under Chapter 468,Florida Statutes as a(n): Contractor Engl er_. Architect—Building inspector License No. (� did personally inspect the: On or about :5—27" Check: Roof Deck Nailing r-� Dry in - Flashing and Drip edge l J Check Which was used: 30#felt Peet and Stick =Other(List) F Keoei�'� -- i At the following 9c�w HC address* -?§ / V Based upon that exami, tion,l have determined the instaliation was done.according.to the Hurricane ' Mitigation Retrofit a al(Rased o Section 553.844,Florida Statutes). Signature• STATE-OF FLORIDA COUNTY OF PASCO i Sworn to and subscribed before this day i BY: Notary Public State of Florida i i r NOTICE OF COMMENCEMENT Permit No. 7/ Tax Folio No. l q4• (o•Z•0211;5 O PM •001 O TBE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,the following information is provided in this NOTICE OF COMMENCEMENT. 1.Description of property(legal des " tion of property):property): �'�� a- I - 0 0 J 0 - c 1 0 00 a)Street(job)Address: 2.General description of improvement(s): '+- O 3. Owner or Lessee info tion(Lessee as ow=only if contractpd for improveme4ts) �� ' �" a.Name and address l CL.� ( k i aws 3&0 4 6 Fty--P zgy - n-1 <<S . RL �E)5Sq a' b.Interest in property: c.Name and address of fee simple titleholder(if other than owner): 4.Contractor Information a.Name and address: H tsamen mooring & uonsir avcs, LLU jts4uts ora Ave, 4epnyrnms, rL 6;354L b.Phone number: Fax No. (Opt.) 5. Surety Information a.Name and address: b.Amount of bond$ c.Phone number: Fax No.(Opt.) 6.Lender a.Name and address: b.Phone number: 7.Persons within the State of Florida designated by Owner upon who notices or other documents may be served as provided by Section 713.130)(a)7.,Florida Statutes: a.Name and address: b.Phone number: 8.In addition to himself;Owner designates the following person(s)to receive a copy of the Lienor's Notice as provided in Section 713.130)(b),Florida Statutes: a.Name and address: b.Phone number: Expiration date of notice of commencement(the expiration date is 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 713.13,FLORIDA STATUES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Verification pursuant to Section 92.S2S Florida Statutes.Under perjury,g , penalties of er I declare that I haul "' read the foregoing and that the facts in it are true to the best of my knowledge and belief. ` '' h `� • Signature of Owner o s ee,or Owng�'s or Lessee's Authorized Officer/Director/Partner/Manager < � $' ; Signatory's Title/Officer: MP ��✓LQ� y c = tl Z3 " P State of Florida x County of Manatee ,�/� °'yr m r T e foregoing instrument was acknowledged before me thiso2 y of i' �/l 20-0b by who is personally known to a or has produced ` 4 .� O L0 4-5 a- -1 - -[-3 -o and who did/did not take an oath. =" (Driver's License#) yam_ Cr �..a. Signature of Notary RpEi2 tate of Florida _Public-State ofr P�n GG 211065 2022 Print,Type,or Stamp I. Commissioned Name of Notary Public 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting r Owner's Name 11 J Owner Phone Nun-M, Z (67V 1 - JAI'111 Owner's Address I-T 1-17 Owner Phone Number 6�q Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address I JOB ADDRESS 1396 140 Af M 2 t' _?31'1� LOT# SUBDIVISION PARCEL ID# _dt I06L 0'O&O� 00 Z n 6 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH e INSTALL REPAIR PROPOSED USE 0 SFR Q COMM 0 OTHER TYPE OF CONSTRUCTION Q BLOCK Q FRAME STEEL A DESCRIPTION OF WORK l'J: ZST0,'J MoAar-1 BUILDING SIZE SQ FOOTAGE= HEIGHT =BUILDING I$ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL 1$ AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING 1$ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS F FLOOD ZONE AREA =YES NO ........ ... .7. BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CUR I' L Y/N I Address License# .ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREh Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N_J FEE CURRY, Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# I- HHHH I I I I I I I 1 2+11+ 11,HH fill Hif I HHHHIt+ RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed. --Sanitary Facilities&I dumpster,Site Work Permit for subdivisionsAarge projects COMMERCIAL Attach-(2)-c9TnpIete_ii&ts of'Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new-constrddoiif_ Minimum ten(10)working-daysft-eT:i Orbidal'd&t-e=.Rinquited onsitei,Construction Plans�,.Stormwatei.01-ans wl Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all he%�Lprqjacis.All commercial requirements must meet compliance__ SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign-back of application,notarized If over$2500,a Notice,of commencement.is required. (AIC upgrades over$7500) Agent(for the contractor)or pc4ret of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE,COUNTER PERMITTING (copy of contract required) Reroots It shingles Sewers fervice Upgrades A/C Fences(Plot(Survey/Footage) Driveways-Not over Counter if ol,pyblic roadways..needs ROW 1 1 NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I -certify that no work.or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that'I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,WaterMastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US'Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the.following restrictions apply to the use of fill: - Use.of fill is not allowed in Flood Zone"V" unless expressly permitted. -If'the,fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If',the fill material is to be used'in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill'material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the;conditions of the building permit issued.under the attached permit application, for lots less than one (1). acre.which are.elevated by fill, an engineered drainage plan is required. If I am the AGENT:FOR'�THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit.prior.to`commencing construction. I understand that a separate permit may be required for electrical work, plumbing,'signs, wells', pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued-shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside:any.provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a-.correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the=work.authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR. PAYING.TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INT D TO OBTAIN FINANCING, CO WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEM FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR ZA Subscribed and swom to(or affirmed)before me this Subscribed and sworn to, ffirm before me this by by Who is/are personally known to me or has/have produced Who is/are personally known to me uc as identification. as identification. Notary Public Notary Public Commission No. Commission No. _ Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped i ///A, BARTLETT ROOFING & CONSTRICTION SERVICES, LLC 38408 3rd Ave. I Zephyrhills, FL 33542 (813) 782-5585 Email: Coreyh@abartlettroofing.com . Lic.-#CCC 1331965 RESIDENTIAL • COMMERCIAL • MOBILE HOMES LICENSED - INSURED - BONDED 0-0-1.190 - ©n 1 0 Date / Name Al �►"` �'`�' 1�� as Address— Phone 5)3— 31 ; — 09 S-7 T DESCR{ 'TIN a r s y AMOUNT ),e Koo s G k I h 1 if c G "I� irol1 � Co�Yw j- I I. "r,� :d 1/e�, s 1��d b��s �- dl►-; �� 00 J S �)IG�. THANK YOU O4r a �� Your Business is Appreciated " Payment upon completion unless previous arrangement made.Warranties pertain to original owner. .All arrangements contingent upon strikes,accidents or delays beyond our control,Owner to carry fire,tornado and other necessary insurance. ,- Our workers are fully covered by Workmen's Compensation Insurance.Customer is liable for any-charges incurred in collecting this bill. t- Q 1 Fa.nrnracc fAA will anniv fn all rrA Tdit card transactions. Tow 7 V 1, 'MIAMI, N fli rVIIAMI-DADE COUNTY j�7! PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 St=t,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 1:(786)315-2599 NOTICE OF ACCEPTANCE (NOA.) GAF I Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:GAF Timberline Ultra HDI Shingles LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting die performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA, ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors d an shall be available for inspection at tale job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1022,21 and consists of pages I through 5. The submitted documentation was reviewed by Freddy Seynitto MIAMPDADE COUNTYM NOA No.: 18-0123.07 Expiration Date:04/22/23 Approval Date,03122118 Page 1 of 5 Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION MEAMMOADE COUNTY m NOA No..18-0123.07 Expiration Date:04/22/23 Approval Date;03/22/18 Page 2 of 5 --- -------- MIAM, U I-DADE MIANII-DARE COUNTY fin : PRODUCT CONTROL SECTION P DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW16 Streci,Room 208 BOARD AND CODE ADMINISTRATION DIVISION . Miami,Florida 33175-2474 'r(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCMTION: GAF Timberline Ultra RDA'' Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENE,WAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date' may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1022.21 and consists of pages I through 5. The submitted documentation was reviewed by Freddy Sendito NOA No.: 18-0123.07 WMIAMMADE COUNTY Expiration Date:04/22/23 �&IIWNDMUNTY Approval Date:03122/18 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Cate -M; Roofing rSub- afforv: Asphalt Shingles huitariial3l. Laminate p� e• Wood SCOPE This approves GAF Timberline Ultra HD®Shingles as manufactured by GAF described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIOMON p din t t W.Va—e-asms Tat Product Deseddlon caulow GAF Timberline Ultra HDO 131/47 x 393/e" TAS 110 Fiberglas reinforced heavy weight asphalt roof Mansoracturi'ng shingle,with a laminate profile. Locations##1,2,3. MANUFACTUPUNG LOCATION 1. Michigan City,IN 2. Myerstown,PA 3. Tuscaloosa.AL EVIDENCE SUBM TTED lot Agency Tit Idegtifiier Teat Name/Renort to Underwriters Laboratories,Inc. ASTM D 3462 4788201324 01/02/17 ASTM D 3462 4788201324 01/04/17 ASTM D 3462 4788201324 12/20/17 TAS 107 02NK41911 11/11/02 TAS 107 03CA35209 10/17/03 TAS 107 OSCA42940 111I1105 TAS 107 06CA10139 09/13/06 M Asphalt Technologies,Inc. TAS 100 GAF-046-02-01 04/05/04 TAS 100 GAF-103-02-01 11/16/05 ASTM D 3462 GAF-103-02-02 11/16/05 LEWTATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. INSTALLATION NOA No.:18-0123.07 C= Expiration Date:44/22/23 Approval'Date:03/22/18 Page 2 of 5 I. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail W,attached. 5. Nailing shall be in compliance with Detail'B',attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo,city and state of manufacturing facility,and following statement:"Miami-Dade County Product Control Approved"or the Miami-Dade County Product Control Seal as shown below. MiAMMMcavi�mr ..... BUILDING PERMIT REQUIREN ENTS: Application for building permit shall be accompanied by copies of the following: I. This Notice of Acceptance. 2: Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this material. NOA No.:1"123.47 .. • Expiration Date:04MM Approval Data 03mns Page 3 of DETAIL A COURSE LAYOUT DECK FULL 5th 17"OFF 4th 11"OFF 3rd W OFF 2nd FULL 1st 5-518"Expascare NOA No.: 1"12307 rstaas orcocavtY Expiration Date:04/2243 If Approval Rate:OR22118 Page 4 of 5 DETAIL B—13-1/4"X 39-3/$" OVERALL DDIENSIONS AND NAM NG PATTERN •-�-39-318" Release Tape 6 fasteners 72� 7�« 1" 13111 Front Side (Maximum Slope 21:12) Tab Sealant 1« 2„ ..n.rr■ 3/$" 112" F Bach Side GAF TIMBERLINE ULTRA HD® END OF THIS ACCEPTANCE , I-� NOA No.: 1"123 07 Expiration Date:O41= Approval Date:03/WIS Page 5 of 5 WA ul NOTE il.#! .:\.y d, • Wit:.::' l..r 1�-ltl' �kl' �•�.h� .,#r .,# �•�.. : MW ram -il: •• q' !1 •(.«TOT Y •Ri1:.L(.1.114J�� • •���.�;1:=1�..} aL lKi\w. 4a i IMTS f « •-} ..At�l.�.l.a: ��� ������ A:w.l-..aal+s_Y...C. "1 1.� ..w... t _ _.,S�La�l:..tla1•. ll Li Oi�Mr ka �w&,�:r�ir1�� 11. Gr ur }` t•.L IL,�[[�, #� ? !s; a+sue" i fir.L'1k {.i;..' is.r...:..7..,. 4tr_,-- z{! Gl��l'�1� 177.SA `�.s .t t:.. V:.S..ri_..,ls 1.�r.(':. - [.a.R'R` +.- !•- la. -.i •il r.M tyi '��:�ji*IT-L. om �•J> Ic '� — 1`s ir:?;12L_ r1i.1:11='..'ft:! ,w :• 111 +3 IRM <t-1!E c'� t It .t <�C i.'�� ,ai:• .:!•iij.. xr��cy' ,}wl.. utr ` ;r•��zRssr. - + Florida"Bullding"Code Online 9125/19,4:24 PM OAM Bt7S"Home Lao in User Registration Hot TOPICS Submit Surcharge Stats d Facts Publications Contact Us BCiS See M8'p LMks Search e' Product.ApproVal Y USER:Public user gt, ►oOres�,j Yrrn,>vmriettor�w--T Seawm>knit r.r,x,Ltt>Application neta0 '.,. FL# FL5293-R35 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus.Drive Parsppany,N]07654 (800)766-3411 mstieh@gaf.com Authorized.Signature Robert Nleminen Ireith@nemoet6.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany,N]07054 (800)"76&3411 TechnlcalQuestionsGAF@gaf.com. Quality Assurance.Representative Address/Phone/Ernail Category Roofing Subcategory Single Ply Roof Systems I i Compliance Method Evaluation Report from a Florida Registered Architect or a-Licensed Florida J Professional Engineer Evaluation Report-Hardcopy Received Florida:Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-50166 Quality Assurance Entity UL LLC Quality.Assurance,Contract:Expiration Date 12/17/2021 Validated By John W.Knezevich,PE. Validation Checklist--Hardcopy Received Certificate of Independence Fi 57.E-R3s COT 2019 Q i GQT WiEh3Trac9-adf Referenced Standard and Year(of Standard) Standard year ASTM D6878 2011 FM 4470 2012 I https://ilorid66uildirig.org/br/t)e app dtl.aspx?param=wGEVXQwtDquwVcULas7wTHoCxgQc%2bdOLPPr3VU5dsgmIM71C3PG9hg%3d%3d Page 1 of 2 a Florida Building Code Online _-::...: 9/25/19,4:2:4 PM FM 4474 2011 TAS 114 201:1 Equivalence of Product Standards Certified By Sections from the Code I[1 PrddUCt Approval.Method Method 1 Option D I Date Submitted 06/19/2019 { Date Validated 06119/2019 Date Pending FBC Approval 06/22/2019 Date Approved. 08/13/2019 Pate Revised 08/1412019 Summary of Products FIL# !Model,Number or Name Description 5293.1 i EverGuard TPO Single-Ply.Roof 'Single-ply,thermoplastic polyolelin roofing systems Membrane Systems Umits of Use Installation Instructions Approved for use in IiVHZ.No FLU -43 235 H 2014 06 FINAL Al ER FL 3 R3,5 pdf Approved for use outside HVHZ:Yes Verified By:Robert Nieminen PE-59166 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:.+NIA/-S02.s Evaluatlon Reports Other:1.)The design pressure noted in this application FL97c)3_R 5 AF 201 06 FINAL-ER FL9293-R35,,ndf relates to one specific assembly In the ER Appendix.Refer to Created by Independent Third Party:Yes the ER Appendix for all systems and associated max.design i pressures.2.)Refer to ER Section 5 for Limits of Use Con us::j6 1 B'q'S[one Read.Tallahassee Ft 32349 2how 8 "E7-fa24 The State of florlda Is an AiyEEO employer.SCt01S1^-ht 2007.2013 Stetii of Florida.::Privacy 5tatemam Under Flortds taw,email addresses arc public records.It you do not want your e-mali address released in response to a puhhcrecords request,do"not send electronic mail to this entity.instead,contact the office by phone or by traditional mail.If you have any quesuoro,please contact 850.467.1395.'Pursuant to Section 455.275(i),Fiarlda Statutes,"effective October 1,2o12,licensees licensed under Chapter 455,F.S.must provide the Dew,Brien with an email address if they have ono-The emalts provided may.be used for article)communication with me licensee.However email"addresses are public record.H you do not wish to supply a personal address,please provide the Department with an emait address F i please e a available to the public.To determine if you are a licensee under chapter {f p�projd�jucctt Approval Accepts: 3�..:.J Fa f:tCl Greg!;Card Safe htips:(/floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXOwt0quwVcULas7i.vTH60xy0c%2bdOLPPr3VUS.dsgmfm7lC3POghgOA3d%3d Page 2 of 2 %sum. crdt tirelatlan(Noalus RbNeara. crap► xd. (rfdte 2) . :,,,t At" lti*"&Gn Faecom Aetadw" Min.19132-Inch plywood One or mace Byers,any prellm. Drt�-Tec n4 Fastener with Ddll Tec21n.0ouble 64mb o.e.wlthln SS•tndt wkk 4px spamd 114.5•Ino Wr57. at max.2 ftSpam comMuatlon attached EvehGuard TPo Subed XHD Plaits oz and sealed with a 1.75-Intl hwrat weld. `a$A Min.19/3ilnchplywood Oneormwe.tayecs,any. P*drm. DriN•Tec014 Fastener with Diin7ec1 in,Double 64nchoG within 5k1ch wide bps spaced Winch MC.and W58. at max:2 ft spans combination. attached EverGuwdTPo Barbed XHD Plates sealed with a OVA*heat weld: 52S Drd!-Tee V14 Fastener nii!!f 069-Tec 21n.Double Min isJ32•inch plywood One arrtho fe layers,ally Pntirra. 12•oxh a c.vdthlia6 teach wide bps spaced 4&tncc#s ow W59. EveihGrrard iPo Barbed 7tFiD Plaits fastened throto deck to 52S at mats.2 ft tiaras comhtnattan attached (over wood tubes)and seated with a 2.5 Inch hest wail, ert8apt%lessjoint,minlrnum I-Inch etehehktnent 0rili•Ter.114 fastener with DriX•Tec 2.3/4 ln. On,i5/32kxhplywrood Daterrnoreltvers,am PreAnt. 12•kxhoc.vAhha64whwtdelapsspaced4&ktctrat. W-60: spars rnmtiinmore attached e". uardTpo 9arbedSXHDPlatesfastenedthroughdeckto .61.5 at mate.2 k engage%oodlolst%mmimuml-inchemedement. (over wood, seatedwttiiai:SLrchhsadwlkl. RUM Dad- tosubtlot 14 ne40 plots 14 an or Aticsorshad MO! Na ("oft1). Toe Attach. Barn ram-11s. Alto& ftdcDw (Pad 38.1ntb o.c.at min.Wnch lap and W 61.- Min,IS/324ricb One or more layer; Loose. GAF startnlafe Anchor Drill-Tec ale Fastener with"Mill-Tec 7$ieel Piste EverUowd Freedom 28-intbor-at two,equaitiy spaces, -4s.8r plywood.24"spans anraombinatiorr Iald SheettMas 48lncttwidei orDriR•TlC3ti.IillJbtdGplwhpete Plate tFtat) 7PolseN,adherad stsnerard cantor rows Min..19/32-Inch One or more &krch o.c.at Mari;4•hich hap and 8 W 62. Viers, Loose- GAF stormSak Anchor 0riU Tee al4 Fastener with Driil Tee 3 in.N16bsd I�o,c.ae two,equsity spaced, EverGuard Freedom 0. plywood;24`spans any combination laid, Sheet tMar.alit h wide) Galvalume Pbte(FEat} staggered testae rows TPO/self adhered System" Do& ItooFt`Aver aRD/ No (riots 1) mondm rse, Fawanen Attardneeeeet (ice Min.19/32-inch plywood it 6•Inch o.c.within5.5•Inchwdde lops spaced 1145-Inch c c.aid w4x nmL 2 ft sty EvarGuard WO Drill-TecM14 Faslerrer with Drill-Tec 2 tn,0ouble Barbed XHD Plates, sealedwith a lJS-.Inch teatweld. 45.0 W-61• Mtn.19/32•Inchplywoodat EverGuardTPD Dn11-TecN14.Fasterw with WII-Tecn. oule BrbedXWP alata -525 6 ho.c wiMinS•lnchsidlelessspatted55lochot.andsoured may.2 ft spans 2l Db with a 1.754n4h heat weld. Min.l5/32•nch plywood at Drift•Tea:414 restener with Dr&Tec 2 in.Double 4asbed Xlm Plates fattened ii-inch o t.within 6-Inch wide laps spaced 484 edt a c.fever W G5. max 2 ft spans Evetti'nard TpO thro h dKk to a 64B W ngallewoodiolsts,.lninhnumi•krdhemedememt wood(ahats}a,dsemleo?withaLS4nchheatweld. Min.15/32-indh plywood et DriC•Tec014 Fastener with Drill-Ter.2.3141ri,.BarbedSWDPbies fastened through : 12•Indhoc.within 6•indh wide Ups spaced48*xhoc.(over W66. mi-ax2Aspass EverGuardip,0 deck toertgasewoodlolsts,mhiimuml4achemedement wooaliolsts}and seastedw{tita2ShKhhiatwttld 7SA KM0 ETC.11C EvatuadionReportO1S06.0.4WR36 ftsr F4S293-F13S Certiflgnt of AuGwrizat on 032455 SA Edition(201n F13C MN4fVN2 EVAIUATiON Revision IS:06/1212019 Premed.by:RoberttlieminerkPE•59165 3411 AppendutpaviSof10 ` ONEmg]etc.. M TaPlitwlttbislaT�r � NllafCOre►(Naf! MOP. OedtlNaF!!1( Iitit�irpYblsalttiY4r fa m Attatb 3N EYERtitiititO FXGZKIM tNl: MIn.224a.,Type6;Grade (Optimial(One ornun: Min,2-166inerglIft"PoMwiniulation,EnerayGWrd Ev"uardkeeibm S:-239. 33 stee{'ar'stroctural. Note 2 i per.1 set •30A'' cariaete byers,arty combination Ulf". Too/seR adhered Min,22p.,,Type 6,Grade: (Optional for recover)One DrM-Tec1112{sledOMy}or.014LVMO4rla•Tet. 5-i44. 33steN or stnlcturai or mare taken,any Wn.D.254ndi 4errs Deck PNme or SECiJAda Gypsum- 3:stserdSrd StaetP1rtes,Ord1-Tec Sin blibcd. i dfl; EverGuard Freedom* concneho combination,min,.i-inch fiber Roof Board G*jAAePlates(iist)orDriA Tee lkrotrsc TPO/saffadered Flat Plate's Of vAI OM-TRe ASAP.45 Min.22 tlaM Type 6,Grade: (Optional)One or mart Min:i'.S.Incb.EnerwGuMd Poli lso tnsubti^£nergyGuard 1 per 2.7 EverGuaid Freedom 5-1d1. 33steel.orstructurat fayetS,any combination UBra Note2 he TPtl/seNadhered 3i.5' concrete Min.22{a.,Type 6,Grade 5-142. 33 ueel.cr strtuttrtal (optional}one or more Min.2 inch EoaWGuard RA.Ene"Guard RN,'or Nate 2 ]per,34 EverGuard Freedom 45.4* concrete 4ay Mimycombination EnetwGuardtlltrs W TP{2/.sttladhered Min.22 aa.,Type 6,Grade Min.d.5-Inch'EnargyGuard ttH HD,Pclyiso.insulation, S•143. 33 steel arstructura( (OpWn4i)one armore EnergyGumdNoPatyrisolmutatloe,EnergyGuardNO'Plus note 2" Iper2ftj "EverGuard freedam AS.O' concrete layers,anycombination Po)yisohudation TPO/sett-adbered Min.22 its.,Type 6,Grade ional One or more Min,1.5-Inch Ere $144. 33 steel at structural (Opt } rgyGuawd Potykw Insulation,EnerytyGuand Note 2 1 per 2fts. EvetGuarci rreedom -45.0' - -concrete layers.any combination Ultra TPO J.sett adherrd MIn.22 tia•rTYpa 6,Grade 5-145. 33.stee(orstmctwai (Optlona!)Qrtewmore Min.2•inchEnergyGu7r1)Pplyiwlnsutattan.£ntrayGuard Note2 i per 29 EvarGuardfreerlom 454` concrete tayers,anycombination Ultra' ftr Tpo/seMadhered Min.22 go..type S.Grade (OpUoaal for recover)One nrfll�Tec 112{steel only)*411e with thill•Tec standard steel Plates,Drdt-Tec 3In..PAbed 1.per 3.2 EverGuad rttedotn 5r146 concretatstructural at more taYeraa+►Y Mtn.0.25krcbSEEUAaLItG uirrftberAool9aard r 454' Gakatume Plates{Flat}atOti�TetMcnTrac ft TPO/SeNadtrered. concrete cortiWnation,.min.2-inch pat platy otwith alp•1'ec ASAP 3; Min.22 aa..Type 6,Grade (Optional for recover{One Dri6Tec#12)steel ontr}or a 14 with Wi-Tec r standard Steel Plates,DrR67a 31n.fibbed EverGuard freedom 5.141. 33 steel or stnsCtural or mate layer,any Min.0.373-inch SECUROCK GWum•Fiber Roof 6uaid I por 4 ftt •ASA* eorwete combination,non.I-inch GMr4lumePlatars{FUt}OnptilTecAccuTrac TPO/seMadhered Rat Plates or with Diftl4 c ASAP.4S Mir 22 g4.,Type$,Grade (OPtion4 Oneor more Min. tntrgyGuvd RA,EneWGuard RN,aw 1 per 1;3 EverGuard Freedom 5-149, 33 steel w Stnrcturai Note 2 -52.S concrete lams,any comb►nation EnasgyGuardtltra hr 11PO/sel)adhered Min.22 ga.,Type S.Grade (Optional)orieor more Min. Ef*isvCuatd RA;EverewGuasd RN.or Ev"uard freedom 5149. 33 steel orstrruturat byem any combhration EnewGuard Ultra Noce 2(r14 and) ].Per 2 flr *0/sell adhered 525 concrete Min22ga,TypeB,Grade (,pt.mOtOrReCWAW)' 4iiFteci>?{stdEtaNy}.orOrH!-Teclti4 ipen fveiGWrditetidom S-15a 330*0orstrih:tural fhitartrwra(iyers.srry MIM0.25-incb Dens Deck Pdme riufane, "t,WUTeeatoabbedGahw" -60A conato" combiratimmet.1-inch "Ale(Flit) lAShs 7P0/'Sndfadhered NE1N0 ETC,U.0 Evaluaf ri Report01S06.03.05•036 far Ft5293413,S, Certificate of Authatitation 032455 G-Editiorr(2017148C NON41VHZ EVAWATM Revlalon 36'.06/t1/2o19 Prepared by:Robed Nienninen.PE-59166 am baerGtiand wo Swaia P)t etonf 34tembnewsVetee tow 74i&M11 Appendix 1:Page 36 at Its. Architectural Detail Drawings zarUM AM OUATGNM FLEKSEAL'CAULK GRADE SEALANT _PRIME MEMBRANE AREA BEHIND SEALANT VJTTH EVERGUARD'TPO PRIMER DRIL TW-TERNINATtON BAR FASTENED E(152am)O.C.WITH DRILL-TEC'FASTENERS REINFORCED EVERGUARV MEMBRANE -_ (PERIMETER'..NEET IF REQUIRED, -- __ WOOD NARER SW(31.8 mm)x a _ (102—i)ANN.SECURED.TO DECK EITERDYGUARD-ROOF INSULATION ROOF DECKSUBSTRATE I EYERGUAHD*WATER-BLOCK OR FLEXSEAL CAULK GRACE SEALANT IUEAIBRAN-E EXTENDS I-ON 1•125.4 mm) o BELOW BAR f� >� ANTE 1:TERMINATION BAR MUST BE FASTENED 6'(152 mm)O.C.FOR THIS DETAIL 2.FOR INSULATION THICKNESS GREATERTWIN(f(203 MX A HARD BDARD IS REQUIRED ON 1 I MECI WMCALLY FASTENED SYSTFIdS OtalY, t�t A APPLY Evemu moTPO CUF EDGE SEALANT To ALL CUT REINFORCED TPO EDGES t (REFER TO EMOUARW,DETAIL 115). � {whp�� Tpp1YY�11�p ="'7ERMtNAT13N BAR ROOF EDGE-. N.7S. �10.1-iT 172 4 ' ^ ---'-------'--~r~---'-------' ---------------�----'--�'----''---'---------'-------------'---'-----` SpecifiCatioh Tables&Guidelines ' INSULATION ATTACHMENT TABLE- (meemn*attachment"eqvmyn°"ts') its Ped WoW Fiber back PVC only 'Attachment requirementsto meet determined uplift resistance are dependent deck type,specific Product Data Sheets INSULATION FASTENING PATTERNSY X 4':(610 mm X 1.2 M)BOARDS. q 6" 1 " 10 24" - • 1 " 6 7 1. 1 • JiYl1 61 i Jacqueline Boges From: Gail Hamilton Sent: Wednesday, May 27, 2020 8:11 AM To: Jacqueline Boges Subject: Re:38640 a ave Hey I'm good with reroof...no need for him to wait Gail K Hamilton City of Zephyrhills CRA Director (813) 780-0202 On May 27, 2020, at 8:07 AM,Jacqueline Boges<boges@ci.zephyrhills.fl.us>wrote: Hello Gail Have a reroof permit with 2 sq of tpo roofing material and the rest is shingle would you like to look at this one location 38640 a ave .The contractor is sitting here in our office wanting to wait for it. thanks Jackie Boges <image001.j pg> 813-780-0020 ext3513 "A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed,a mere doctrine, but it is He Himself we have."Dwight L. Moody Florida has a very broad public records law. Electronic communications regarding most City of Zephyrhills business are public records and available upon request. Your e-mail communications may therefore be subject to public disclosure. If you received this message in error, please do not read, forward, copy, etc. and delete immediately. Disclaimer:Fla.Stat.668.6076"Under Florida law,e-mail addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact this office by phone or in writing." 1