Loading...
HomeMy WebLinkAbout20-181 l I m Q I City Of ZephyrhillS PERMIT NUMBER ' 5335 Eighth Street - Zephyrhills, FL 33542 BGR-000181-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 06/19/2020 Permit Type: Building General (Residential) Property Number Street Address 35 25 210120 00000 1400 7924 Merchantville Cir Owner Information Permit Information Contractor Information Name: JOHN&MARGARET RATERING Permit Type:Building General(Residential) Contractor: MOMENTUM SOLAR Class of Work:Electric Service Replacement/ Contractor: MOMENTUM SOLAR Address: 18002 Richmond Place Dr APT 2925 Building Valuation: TAMPA,FL 33647 Electrical Valuation:$27,795.00 Phone: (813)426-2046 Mechanical Valuation: r Plumbing Valuation: Total Valuation:$27,795.00 Total Fees:$268.47 Amount Paid:$268.47 Date Paid:6/9/2020 1:59:51 PM Project'Description INSTALLATION PHOTOVOLTAIC SOLAR ROOF MOUNT Application Fees Electrical Plan Review Fee $89.49 Electrical Permit Fee $178.98 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNAfUB9 PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance With any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW'(Chapter 713, Florida Statutes,as amended): If valuation of work is$2j500.00 or more, I certify that Ij the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide' prepared by the Florida Department of Agriculture and Consumer Affairs. If the applitant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and Installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commending construction. I understand that a separate permit.may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter,or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit Is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) 1 OWNER OR AGENT CONTRALTO 1% =,d4y q ="Iy I a W"I Subscribed and sworn to(or affirmed)before me this Subscribed and s�i6ir o(or'affi ed�—Inforr(gthl -Hn e by by (24 , J:!:�MQ Who is/are personally known to me or has/have produced Who islare personally known to me or hash produced as identification. as Identification. Notary Public Notary Public Commission No Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped I ` 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 321 247 _ 6073 Trrrrr rr i Owner's Name Margaret Ratering Owner Phone Number 813 426-2046 Owner's Address 1 7924 Merchantville Cir Zephyrhills FI 33540 Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 7924 Merchantville Cir Zephyrhills FI 33540 LOT# 140 SUBDIVISION Crestview Hills PARCEL ID#1 3525210120000001400 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED B NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR Q COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK Installation of photovoltaic solar panels on rooftop BUILDING SIZE I SO FOOTAGE HEIGHT BUILDING $ �1 VALUATION OF TOTAL CONSTRUCTION 1�5 ELECTRICAL $7 ots AMP SERVICE a-S. _ P11 ENERGY Q W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY I Momentum Solar SIGNATURE REGISTERED I Y/ N FEE CURREt Y/N Address 6210 Hoffner Ave.Ste 100 Orlando,FI 32822 CVC57036 License# ELECTRICIAN COMPANY Momentum Solar SIGNATURE REGISTERED I Y/ N I FEE CURREt Y/N Address 6210 Hoffner Ave.Ste 100 Orlando,FI 32822 License# FEC13008217 PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N FEECURREA Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREA I Y/N Address License# IIIIIIIIIIIIIIItllllllllllllllllllllllltllllllllltlllllllltllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stonmwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades AIC Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW y`.p,_" Imo, •'t.�. K• � City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: /" 'o w e y, 4L-.,m so l c-- y' Date Received: Site: Permit•Type: vt,S'�h �7�yYi ,0 Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comm s eet all be kept with JUnp o it and/or plans. ' I Kalv7itzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) 5/28/2020 35-25-21-0120-00000-1400 1 Pasco County Property Appraiser Parcel ID 35-25-21-0120-00000-1400 (Card: 1 of 1) Classification 00100-Single Family Mailing Address Property Value RATERING JOHN D & MARGARET S Ag Land $0 18002 RICHMOND PLACE DR APT 2925 Land $15,561 TAMPA, FL 33647 Building $129,824 Extra Features $981 Physical Address 7924 MERCHANTVILLE CIRCLE, Just Value $146,366 ZEPHYRHILLS, FL 33540 Assessed (Non-School Amendment 1) $141,400 Legal Description (First 200 characters) See Plat for this Subdivision Non-School Taxable Value.. $141,400 CRESTVIEW HILLS PB 53 PG 124 LOT School District Taxable Value $146,366 140 Warning: A significant taxable value increase may occur when Jurisdiction sold. CITY OF ZEPHYRHILLS Click here for details and info. regarding the posting of exemptions. Land Detail (Card: 1 of 1) Line Use Code Description Zoning Units Type _Price 'Condition Value _ 1 010OR LP1-1 SFR OPUD. 6,300.00 SF $2.47 1.00 $15,561 Additional Land Information Acres Tax Area FEMA Code Res Code Com Code Co_ndo Code 0.14 30ZH X CVHL CVHL CVHL View Sketch Building Information - Use 0100-Single Family Residential (Card: 1 of 1) Year Built 2005 Stories 1.0 Exterior Wall 1 Concrete Block Stucco Exterior Wall 2 None Roof Structure Gable or Hip Roof Cover Asphalt or Composition Shingle Interior Wall 1 Drywall Interior Wall 2 None Flooring 1 Ceramic Clay Tile Flooring 2 Carpet Fuel Electric 'Heat Forced Air- Ducted /C Central Baths 2.0 Line Code Description Sq. Feet Value- 1 BAS01 LIVING AREA 1,564 $116,358 2 FGR01 FINISHED GARAGE 400 $11,904 3 FOP01 FINISHED OPEN PORCH 84 $1,562 Extra Features Card: 1 of 1 Line Code Description Year Units Value 1 ', RDWSWC DRVWAY/SIDEWALK CONC 2005 517 $981 Sales History Previous Owner: RAINTREE COUNTY LLC Month/Year Book/Page Type DO_R Code 'C_ondition Amount 03/2020 10074 / 2729 Warranty Deed 01 Improved $196,100 12/2010 8498 / 1209 Quit Claim Deed 11 Improved $0 05/2010 8341 / 1444 Warranty Deed 01 Improved $96,000 02/2007 7424 / 1870 Warranty Deed Improved $0 02/2007 7398 / 1741 Warranty Deed Improved $0 05/2006 7410 / 0297 Warranty Deed Improved $0 hops://search.pascopa.com/parcel.aspx?parcel=2125350120000001400 1/1 INSTR# �084955 OR BK 10 7 09 PG 670 Page 1 of 1 05/28/2020 03:09 Fiv1 Rcpt:2166020 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller Permit Number: FoliolParcel ID#: 23525210120000001400 Prepared by: Kristin Wiggins/Momentum Solar 6210 Hoffner Ave,Suite 1, Orando,FL 32822 Retum to: Momentum Solar 6210 Hoffner Ave,Suite 1 Orlando,FL 32822 NOTICE OF COMMENCEMENT State of Florida,County of The undersigned hereby gives notice that Improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement. 1. Description of property(legal description of the property,and street address if available) _CRESTVIEW HILLS PB 53PG124LOT140[7924 Merchantvilie Circle Zephyrhifls F133540 2. General description of Improvement Installation of photo voltaic solar panels on rooftop 3. Owner information or Lessee Information If the Lessee contracted for the Improvement Name Margaret and John Ratering Address 7924 Merchaniville Circle Zephyrhilis FI 33540 Interest in Property Owner Name and address of fee simple titleholder(if different from Owner listed above) Name N/A Address 4. Contractor Name Momentum Solar/Cameron Christensen Telephone Number 321-247-6073 Address 6210 Hoffner Ave,Suite 1,Orlando,FL 32822 5. Surety("If applicable,a copy of the payment bond is attached) Name NIA Telephone Number Address Amount of Bond $ 6. Lender Name N/A Telephone Number Address 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by§713.13(1)(a)7,Florida Statutes. Name N/A Telephone Number Address 8, In addition to himself or herself,Owner designates the following to receive a copy of the Lienoes Notice as provided in§713.13(1)(b),Florida Statutes. Name N/A Telephone Number Address 9. Expiration date of notice of commencement(the expiration date will be 1 year from the date of recording unless a different date Is specified) WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. �/ '� 2 1T� Owner Sign nsror Lessee er's tr Lessee's Authorized Officer/Director/Partner/Manager Signatory's Title/Office The foregoing instrument was acknowledged before me this 28 day of 05/20 by Margaret Ratering monffWr name of person as Owner for Type of eutho'y,e.g.,officer,trustee,attorney In fad Name of spaarrt`y on behalf of whom In►struument was executed Sigmdu of N late of Florida Print,type4�stam��commissioned of Notary Public Personally Known OR Produced ID X �a. Notary W, tState.111 orida Type of ID PSo�uced D.L. Lauren E EI Teher, ine Or n erso A My Comnffasion GG 208001 y�F Exorea 04/04=3 Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman NJ.08558 908-872-3664 StudioGdesign@comcnst.net May 27,2020 Re:Proposed Photovoltaic Solar Panel Installation Margaret Ratering 7924 Merchantville Cir Zephyrhills,FL 33540 Dear Plan Reviewer: Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that an inspection was performed by a representative of the Architect/Engineer of Record,and analysis of the existing structure was conducted.There is adequate structural capacity for the installation of the array with the following recommendations: 1.The array will be installed on the existing roof.The roof framing is constructed of 2"x4"wood trusses @24"o.c. spanning 20'1"with a top chord length of 227'with intermediate supports at 1/3rd points,making the effective longest span equals 87' with 1/2"plywood sheathing.The new array(See Site map by contractor)will add 2.63 Lb./ Sf.overall to the roof.No additional structural support is required for the roof structure. 2.The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed instructions.The attachment system shall be UL 1703 approved tested.Provide 6 mil.vapor barrier between dissimilar metals.Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual.The panel angle shall match the roof slope.Reference summary table below: Roof Type: Shingle Fastener Max Spacing(in.) Attachment System: "Ecofasten Solar""Rock-IT"® Wind Zone 1 Wind Zone 2 Wind Zone 3 Fastener Info: min.5/16"x 4"long stainless-steel lags with a min. 48 24 24 embedment of 3 into the rafters 3.Solar Modules shall be UL-1703 rated.Refer to manufacturers specifications sheets. 4.Positive drainage of the system shall be so as not to void the existing roof warranty. 5.All aspects of the installation shall comply with the Florida Administrative Code,2017 Florida Building Code- Residential Sixth Edition,ASCE-7-10,2017 Florida Building Code—Energy Conservation,Sixth Edition,2014 National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by law.All components used meet the criteria of the Florida Solar Energy Center. 6.Please refer to the attached structural calculations. If you have any questions relating to this matter,please contact me at your earliest convenience.Thank you. _ OP EL w, o Daniel W.Dunzik,RA.LEED-AP sly i FL.Lic.No.AR98795 �': 'Ala ARC e Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman NJ.08558 908-872-3664 StudioGdesign@comcast.net May 27,2020 Gravity Load Calculation Criteria Structural Design Loads per ASCE 7-10 Dead Loads= 10 psf+2.6 psf(new solar panels)=12.6 psf Roof Live Load=20 psf Ground Snow Load=0 psf Wind Load Calculation Criteria Wind Loads per ASCE 7-10,Ch.30 method 1 Using an area of 10 SF,wind loads from Figure 30.5-1: Zone 1 =-32.3 psf Roof Slope=25 degrees Roof Mean Height= 15 ft Zone 2=-56.2 psf Basic Wind Speed= 140 mph Zone 3 =-83.1 psf Exposure=B Per section 2.4.1,ASD combo=D+0.6W: Zone 1 =2.6 psf+0.6(-32.3 psf)_-16.8 psf Zone 2=2.6 psf+0.6(-56.2 psf)_-31.1 psf Zone 3=2.6 psf+0.6(-83.1 psf)_-47.3 psf Check Attachment to Wood Truss Use 5/16 dia.Lag screw w/3"embedment into 2 in.wide roof rafter Lag Screw Spacing: Lag Screw Tributary Area: Zone 1 = 48"o.c.max Zone 1=(48".o.c.max)^2/144= 16 SF Zone 2= 24"o.c.max Zone 2=(24"o.c.max)^2/144=4 SF Zone 3= 24"o.c.max Zone 3=(24"o.c.max)^2/144=4 SF Lag Screw Forces: W=2661b/in(Table 12.2A,2015 NDS) Zone 1 = 16.8 psf x 16 SF=269 lb < W', OK Cd=1.6(Table 2.3.2,2015 NDS) Zone 2=31.1 psf x 4 SF= 124 lb < W', OK Ct=1 (Table 2.3.3,2015 NDS) Zone 3=47.3 psf x 4 SF= 1891b < W', OK W'=W x embed x Cd x Ct W'=266 lb/in x 3 in.x1.6 x 1=1276.8 lb Powered by DUO' � x Q«cs � ' 'iAvy .:. ), GtualityToeted I-tOPBkgfrD:W \\ 2019-. 0032587 Q.ANTUM TECHNO Higher yield LOGY•'LOW LEVELIZED Power class Rer surface area;Power BOS c COST. ssas,.and an efficiency to s,higherOF ELECTRICITY rate of •�, INNOV up to 0- ATIVEALL-WEATHER Optimal yields,whatever the TECHNOLOGY excellent low-light and tem weather with Perature behavior, ENDURING HIGH p ERF '- Long-term yield ORMANCE Hot- pot PS security with Anti LID and Anti Pi rotect and Traceable Quality D Technotogyl. ty Tra.Q*n+ EXTREME.WEATHER RATING High-tech aluminum alloy frame, (5400Pa)and wind loa ds certified for (40oop high snow LE 0 A RELIAg a)regarding IEC. 1 inclusiveINVESTMENT 2-yea linear pe r product warranty and 25 Year rformance guarantee2, STATE,OF THE ART Q.ANTUM MODULE TECHNOL OGY and innovative wiring O combi with 9 nes cutting edge cell 'APT.testconditions Q-ANTUM T separation echn 'See data sheet according to iEC/Ts 6 804 ology on rear for further tnicnnatto�- 1;2015,method 9(-1500 V,168h) . THE tDEgL SoLUT1pN FOR; W--' RoofioP erraYs on "11...--� restdentialbui!dings Engineered in Germany MECHANICAL SPECIFICATION Format 68.5 x 40.6 x 1.26 in(including frame) (1740 x 1030 x 32 mm) Weight 43.9lbs(19.gkg) Front Cover 0.13 In(3.2mm)thermally pro-stressed glass with anti-reflection technology 4x I 0-ft p,�,,o M) Back Cover Composite film Frame Black anodized aluminum Coll 6 x 20 monocrystalline Q.ANTUM solar half cells Junction 130y, 2,09-3.98 x 1.26-2.36 x 0.59-0.71in(53-101 x 32-60 x 15-18mm),Protection class IP67,with bypass diodes Cable 4 MM2 Solar cable;(+)a45.3 In(1150 mm),(-)z45.3 In(1150 mm) Connector Stf3ubil MC4,Amphenol UTX,Renhe 05-6,Tongling TL-CableOlS, JMTHY JM601;IP68 or Friends PV29;IP67 I�Iuwffls-)(M m T ELECTRICAL CHARACTERISTICS POWER CLASS 330 335 340 345 MINIMUM PERFOR M A NCE AT STAN DARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W -0 W) Power at MPP' pmPP IM 330 335 340 345 Short Circuit Current' Ic [A) 10.41 10.47 10.52 10.58 E -Open Circuit Voltage' Voc IV] 40.15 40.41 40.66 40.92 72 Current at MPP IMPP [A] 9.91 9.97 10.02 10,07 Voltage at MPP VWP IV] 33.29 33.62 33.94 34.25 Efficiency' q [%] 2:18.4 2:18.7 2:19.0 ?.19.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP PMPP [W) 247.0 250.7 254.5 258.2 E Short Circuit Current Ise [A] 8.39 8A3 BAB 8.52 E Open Circuit Voltage Voc IV] 37.86 38.10 38.34 38.59 7E Current at MPP IMPF [A] 7.80 7.84 7.89 793 Voltage at MPP Vv- [VI 31.66 31.97 32.27 32.57 'Measurement tolerances Pma,±3%;l6c:Voc*5%at STC:5000W/mr,25±2*C,AM 1.5G according to IEC 60904-3-1800W/m2,NMOT,spectrum AM 1.5G 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ----- ------ At least 98%of nominal power during first year.Thereafter max-0.54% degradation per year.At least 93.1% of nominal power up to 10 years.At ----------- least 85%of nominal power up to n 25 years. J, All data within measurement tolerane- ea as.Full warranties In accordance with "Do 000 .0W the warranty terms of the 0 CELLS sales organization of your respective 9 country. Typical module performance under low Irradiance conditions In comparison to STC conditions(25cC,1000W/m2) TEMPERATURE COEFFICIENTS Temperature Coefficient of 1,c a [%/K] +0,04 Temperature Coefficient of Voc ff [%/K] -0.27 Temperature Coefficientrating Temperature NMOT [*F] 109*5A(43*31C) of P_ y [%/Kl -0.36 Normal Module Operating 0 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS IV] 1000 Safetycless II o Maximum Series Fuse Rating (A DC] 20 Fire Rating C(I EC)/TYPE 2(UL) 0 Max.Design Lead,Push I pU113 [lbs/ftq 75(360OPa)/55(26t7F`a) Permitted ModuleTemperature -40*Fupto+:L85'F(-40*C up to+85*q on Continuo-a Duty Max.Test Load,Push/Pull' [lbs/ft2] 1.13(540OPa)/84(400OPS) 'Sea Installation Manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION,+ a � UL 1703,VDE Quality Tested,CE-compliant,IEC 61215:2016.IEC 61730:2016, Number of Modules per Pallet 32 Application Class 11,U.S.Patent No.9,893,215(solar cells) Number of Pallets per 53'Traller 28 Number of Pallets per 40'HC-Container - 401 Pallet Dimensions(LxWx H) 71.5 x 45.3 x 46.9 in(18 2415x1150X119DmM) r.IM Pallet Weight 15051bs(683kg) Note:Installation Instructions must be followed.See the Installation and operating manual or contact our technical service department for further information on approved Installation and use of this product. Hanwhe Q CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1949 748-59961 EMAIL inqulry@us.q-cells.com I WEawww.q-cells.com/na i 1 Data Sheet Enphase Microinverters Region:AMERICAS The high-powered smart grid-ready Enphase Enphase IQ 7 Micro' and Enphase IQ 7+ Micro" IQ '7 and IQ 7+ dramatically simplify the installation process while. achieving the highest system efficiency.- Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with.the Enphase IQ Envoy"", Enphase IQ Battery"", and the Enphase Enlighten"" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations-and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved,lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules More than a million hours of testing • Class II double-insulated enclosure • UL listed 0 Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements Remotely updates to respond to changing _ grid requirements Configurable for varying grid profiles Meets CA Pule 21 (UL 1741-SA) The IQ 7+Micro is required to support 72-cell modules. To learn more about Enphase offerings,visit enphase.com `/ E�1 PHASE. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonk used module pairings, 235 W-350 W.+ 235 W-440 W+ Module compat.ibilRy 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC yoliage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Ise) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA -295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2- 240 V/ 208.V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5.% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -400C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-13-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at s•// nphase.com/en-us/support/module-com atp ib*lity 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Referto local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com :1 EN PHASE:. @ 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 1 s Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman,NJ.0855E 908-872-3664 January 29,2018 Building Department Attn:Plan Reviewer Re:Proposed Photovoltaic Solar Panel Installation Dear Sir: I have reviewed the following documents related to the"EcoFasten Solar"ROCK IT SYSTEM 4.0 and certify that the attachment system when installed in strict compliance with the manufacturers Installation Manual appropriate for this application and is in compliance with the latest building codes including Florida Administrative Code,2017 Florida Building Code-Residential Sixth Edition, ASCE-7-10,2017 Florida Building Code-Energy Conservation, Sixth Edition,2014 National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by law.I make this certification for the following listed documents: 1. ROCK.-IT SYSTEM 4.0 Installation Manual 2. PZSE,Inc Structural Engineers Certification. 3. EcoFasten Solar Certificate No.US 82150026 4. ROCK-rr SYSTEM 4.0 Cut Sheet for Coupling,Hybrid Coupling,and Mount. If you have any questions relating to this matter,please contact me at your earliest convenience.Thank you: Daniel W.Dunzik,RA.LEED-AP Fl.Lic.No.AR98795 e O F •.O 1EL W UN 9 n% AR98795 ,�1., Cut Sheet - RocknIt-4.0-Cou piing 1. Installation to be completed in accordance with manufacturer's.written specificatidns and installation instructions. 2. See spec sheet or contact man'ufacturer-for-detailed.material,finishes,and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. 3.1-7in 0 [80'.54M Mi 7.00in 117730mml 2.02in d 2.14in 2.34in F51-38mm] -[54.37mm i '59.36mm 32mm 35mm Anmm *ALPINE 4741 W Polk Stree Ste.komwGUARDS EcoFas ten Solar Phoenix,AZ'85043 Toll.Free-Phone 1.888.766.4273 Toll Free Phone 1.877.859.3947 Material:See Spec Sheet Toll Free Fax 1.888.766.9994 Toll Free Fax 1.'888.766.9994 Scale: 1:4 -6/28'/2017' ASb: E Ft".' X Cut Sheet - Rack-K 4.0-Hybrid Coupling 1. Installation to be completed in accordance with:manufacturees written specifications and installation instructions. 2. See spec sheet or.contact manufacturer for-detailed.material,'finishes,and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawinggs. 5. Subject to change without notice. I 3.1 bin 0 0 4) [80.29mm] 7.00in -� [177.80mm] ,.�. M m 5.00in [127mm j 2.02i6 C' 2.14in a 2.34in I� [51.38mm] [54.37mm] [59.36mmJ 32mm 35mm �40mm - ALPINE 4741 W Polk Street Ste.4 ' ��� st,:V ��,` n S0l21�•�" Phoenix,AZ 85043 Toll Free-Phone 1.888.766.4273 Toll Free Phone-1:877.859.3947 Material:See Spec Sheet Toil-Free Fax 1.888-766.9994 Toll Free Fax 1.888:766.9994 Scale: 1:1 6/28/2017 ASG: - EFS:-x t a ROCK-.IT SYSREw4.Q . RAIL-FREE RACKING UTluzeS ECOFaSTen SoL.arS PaTenTeo.TeCHnOLOGY uAll,, EcoFasten."Solar® v r , Co astenSolar@ Committed to the connection Document Date:9.8.2017 Contents Pg. 1..................................................................................................................................................... Assets of Design. -Features System Components Pg. 2 .............................................................................................................................. -Rock-It 4.0 Mount Assembly Rock-It 4.0 Coupling Assembly Pg.Pg. 3 ........................................I..............................................I.................... Rock-it 4.0 Hybrid.Mount Assembly Rock4t.Clip SS Assembly- Rock-lt:Clip-.2.0.Assembly Pg..4.......................................................................................................................................................... Array Layout GreenFasten Flashing Install Pg. 5..................................................................................................................................... Rock-It System 4.0*Install Pg.-6................................................................................................................................................. Ground Lug.Install Pg..7 .......................................................................................................................................... Rock-It Clip SS Install Rock-it Clip 2.0-Install Pg. 8-12 ............................................................................................................................. Standoff.Spacing Tables. Snow Load 0-20.psf Snow Load 21-30 psf Snow.Load 3140 psf Snow Load 41-50-psf Snow Load 51-60 psf Pg. 13 ................................................................................................................................... Grounding Information, -Bonding Assembly and Bonding Path Pg. 14 ............................................,...................r............................................... Thermal Expansion and Bonding Bracket:Spacing- Staggered Layout Cantilever P& 15.. . ................................................................................................................................... System Specifications Evaluated, Compatible Modules Y ROCK-IT SY STeM: 4.0- Designed with the installer in mind. EcoFasten.Solar specializes in solar roof attachments that are fast and-easy to install,straightforward,secure and cost-effective.EcoFasten offers a wide variety of standard products as well as custom solutions,for a one-stop source for all of your rooftop anchoring needs. Products are rigorously tested and approved above and beyond industry- standards in-house:and by third party agencies. EcoFasten's patented conical sealing system has been in service in the.snow guard and.solar industries for two-decades.- FeaTu.res • New and improved design" North-South adjustability- • Fastest,easiest to level system on the market -Only one tool required(1/2"deep weli:socket) Integrated electrical-bonding Vertical adjustment of 3"4-- • SIMPLE-only-4 components" SYSTem comPOnenTs* - reauire.D__NZ Ilk lam• .5 ��p' - ROCK-IT SLIDe ROCK-IT 4.0 ROCK-IT AO COUPLInG'. ROCK-174.0 4• For COMP.SHinGLe MOUriT & LOaD searinG FOOT Array 'SKIrT s•.For TILe SYSTem comPOnenTS* OPTIOnaL PIP" ROCK-IT.CLIP SS ®C��]EcoFasten::Solat® p" (ReFer TO PG.6) EcoFasten Solar products are protected by the following U.S.Patents: 8,151,522 8,153,700 8,181;398 8,166,713 8,146,299 ROCK-IT 4.0 8,209,914 8,245,4S4 8,272,174 8,225;557 9,010,038 ROCK-IT 4.0 ArraU SKIr r 9,134,040 9,175,478 9212,833 HWBrID MOur1T EnD CAPS m saa� oon E .(ReFer TO PG.:S) PrereasT ROCK-IT CLIP-2.0 enD of skirl secnons) (ReFer TO PG. 6) *Components for use with 32mm modules"are available as special order:Components for use with 32mm modules are labeled as such.on system packaging.Please refer.to evaluated;.compatible modules grid.on page 15 to identify system compatible 32mm modules. www.ecofastensolar.com. info@ecofastensolar com: 877-859-3947 1 f ROCK-IT 4.0 MOUr1T ASSemBLY I NOTe: ITems 1-7 SHIP assemBLeD 1 5/16"-18 x 1.75"Hex Serrated Flange Bolt 300 Series SS 2 Rock-It 4.0 Mid-Clamp 6000 Series AL 3 Rock-It 4.0 Shelf 6000 Series AL 4 Flange Level Nut 300 Series SS 5 Rock-it 4.0 Tie Plate 6000 Series AL 6 Rock-It Pedestal 6000 Series AL (Z' 7 5/16"-18 x 3/8"Hex Serrated Flange Bolt 300 Series SS ,- j� 8 3/8"ID Star Washer 300 Series SS 9 3/8"-16 x 3"Hex Tap Bolt 300 Series SS ROCK IT SLIDes are aCCePTaBLe BracKeTS For Use WITH ROCK-IT 4.0 (SOLD SeparaTeLU) ROCK-IT 4.0 COUPLING aSSeMBLY NOTe: ITems 1-3 SHIP assemBLeD 1 5/16"-18 x 1.75"Hex Serrated Flange Bolt 300 Series SS s2 ---}; 2 Rock-It 4.0 Coupling Mid-Clamp 6000 Series AL 3 Rock-It 4.0 Coupling Shelf 6000 Series AL \� 4 Rock-It Load Bearing Foot Clip 5 Rock-it Load Bearing Foot Base 1 4All, %. � \� a I I www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 2 c ► ROCK-IT 4.0 HYBRID MOl.. nT ASSemBLY NOTe: ITems 1-10 SHIP assemBL_eD 1 Rock-It 4.0 Shelf 6000 Series AL 2 Rock-It 4.0 Coupling Mid-Clamp 6000 Series AL j 10 3 Rock-It 4.0 Coupling Tie Plate6000 Series AL 4 Flange Level Nut 300 Series SS 5 Rock-it Pedestal 6000 Series AL 6 Rock-It Slide 6000 Series AL 7 3/8"-16 x 3"Hex Tap Bolt 300 Series SS a�;1 8 3/8"ID Star Washer 300 Series S 9 5/16"-18 x 3/8"Hex Serrated Flange Bolt 300 Series SS 10 5/16"-18 x 1.5"Hex Serrated Flange Bolt 300 Series SS 0 I J� I.% 6 \ y``(J ROCK-IT CLIP SS ASSeMBLY ROCK-IT CLIP 2.0 ASSeMBLY NOTe: ITems 1-3 SHIP assemBL.eD NOTe: ITemS 1-3 SHIP assemBLeD 1 Stainless Steel Carriage Bolt-.313-18X.75 1 Rock-It Clip 2.0 2 Rock-It Clip SS 2 Stainless Steel Flange nut.313-18 3 Stainless Steel Flange nut.313-18 3 Bolt.3125-18x1x1-S NO I i www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 3 Array LaYOUT • Find the required structural attachment points. Mark these using a vertical(N-S).chalk line on the center of the rafters. • Spacing may.vary depending upon project specific structural requirements;Le:high snow and wind load areas may require lesser bracket spacing,in the E-W axis vs.the maximum spacing.Max spacing is 48"for.portrait orientation and 72"for landscape orientation..Consult project layout diagram for project specific bracket spacing on the.roof. • Install-Rock-It Mounts to predetermined mount spacing. • The Rock-it Array Skirt sections are.the width of a typical 60.cell module—.use the.Rock-It Array Skirt.as a guide to'lay out module placement. Note:The distance between the rows of mounts is calculated by the module dimension N-S plus T 3/8" (35mm).Lag screw should be Installed as close to center-of exposed shingle as possible..The minimum. distance between the lag screw and the edge of shingle is 1/2" -GreenFaSTe.nTm FLaSHinG InSTaLL i Locate the rafters and snap horizontal and,vertical lines to mark the installation_ position for each GreenFasten flashing. WFA &_ 2. Drill a pilot hole ON'diameter)for the lag bolt Backfill with sealant.Ecol asten Solar recommends an.EPDM mastic. 3 -insert-the flashing so the top part is underthe next row of shingles and pushed far f' enough-up.slope to prevent water infiltration through vertical joint in shingles.The leading edge.of flashing must butt against upper row.of nails to preventtuming. when torqued. 4 Line up pilot hole with GreenFasten flashing hole. insert the lag bolt through the EPDM bonded washer,the Rock-it slide,the gasketed. hole in the flashing and Into the rafter. Torque:The range Is.between,100-140 torque Inch-pounds depending on the type of wood and time of-year.The visual.lndicator.for proper torque is when the EPDM on the underside of the bonded washer-begins to push out the sides as the washer compresses.If.using an impact wrench to install the fasteners.be careful not to over torque the fastener.You may.need to stop and use a ratchet to finish the install. 9be Engineer of Record shall check capacity of rafter to support lag screw loading. www.ecofastensolarcom info@ecofastensolar.com. 87-77859-3947 4 ROCK IT SY,STeI'l`1 4.0 insTaLL •..*•f'.i. III � 1C' III III I - I R 1 Fig.A install EcoFasten solar Flashing with Rack-It.Mounts •FollowEcolastenSolarinstalllnsWctloniforflashingandbracketIstall(GreenFastenshownabove).- •optimum vertical distancebetween tag bolts Is 1 3Arplus module dimension. •SetountsoneavemostmwsothattheRodcatPedestalisontheSouthendofRock-RSRds • mSet mounts on allupper mwsso thattheRod0tPedlestal'Is on the North end of Rod(4t SH& 2 Install Rock-It Array Skirt onto Eatre Mounts • Slide Rock-It Array Skirt into front channel on Rock It Shelf. •Array Skirt Enid Caps are pre-Installed on the East end of each skirt sectlon,and are used to couple the skirt sections where needed(see Fig.A). Tighten Mid-Clamp bolt,clamping Rocklt Array Skirt-to mount.Torque to 200 dribs.(130 in-lbs,when Installing with 32mm modules). —q- Install Rock-it Couplings(when joining 4 panels with a Couplingrthe use of a load bearing foot Is,required) • Prior to mounting on the roof,snap Load Bearing Foot Into the bottom of.Rodc-It Coupling If required. (Each Load Bearing Foot is set to same height as the Rock-it Mounts-adjust accordingly) • On eave row only,slide Rockit Array Skirt onto Rock It Coupling Shelf.Torque to specified value. • NOTE:If a coupling lands-on a rafter,the Hybrid Mount'should be used in place of the'Rock-It Coupling(refer to image:3a). "Hybrid Mount can be made in the field by assembling a coupling to a mount pedestal,or by purchasing separately, C, Align and Straighten First Row of the Rock-it System with Rock-it Array.Skirt •Use North-South adjustment of the Rock4t Pedestal to straighten Ro&4t Array SkIrt and align module with Array SklrL •Torque screw on side of Rock-it Pedestal toISoin-ibstosecureitto the Rock-ItSlide. -Adjust Flange Level Nut tolevel the system(optional—can be leveled daringoraRerkutatlatlim)• 6-7 Install 1st Row of PV Modules •Slide upslope Rode-It Mounts down to engage top of first modulo— Install Rock-ItCouplIngs on the upsiope side ofist raw ofpanels. -Tonlue2nd row ofMid:ClampsonRock-It Mounts and Rock-it Couplings to specified value. •Install balance of PV modufesensudng that the Rock-ft Ped.estali are in the appropriate position,then torque MId-Clamps to secure moddes. 10 Level the Rock-it System •when assembly Is complete,level the entire system by adjusting Flange Level Nuts(Flange Level Nuts have no torque value). • Height between roof surface and underside of modules should be 3"or less,when Installed with iWw 2 modules INSTALLATION NOTE:Modules should.be Installed so that theJunctlon box is installed upslope,•away.from the-leading edge of the array. www.ecofastensolar.com iiifo@ecofastensoiarcom 877-859-3947 -5 GrounoinG--LUG jnSTaLL Necessary Components: One of the following ground lugs(or any UL 2703 compliant ground lug): Burndy CL50-1TN Ground-Lug(UL 2703-E351343 / UL 467-E9999) ILSCO SGB-4'Ground Lug(UL 2703-E354420 /UL-467-E34440) ILSCO GBL-4DBT,(UL 2703-E354420 /UL 467-E34440) ILSCO GBL-4DBTH(UL 2703 E354420 /.UL 467-E34440) ILSCO GBL-4SS(UL 2703-E354420 /UL 467-E34440) Note:Driltand.deburr hole in Ground Lug prior to Installation - 14 AWG-4 AWG Copper Ground Wire* Torque Values: - 8.32 x 0.5"Serrated Flange Head Bolt(300 Series SS), 14-10-AWG=20 in-ibs. 8-32 Serrated Flange Nut(300-Series SS) 8 AWG=25 in-ibs. 11/32"and-1/4"wrenches or ratchets/sockets 6-4 AWG=35 in-lbs. 1 Insert the flange bolt into the module ground hole:Place Star Washer over bolt.Place ground lug over the bolt.and Star-Washer,and turn to desired orientation. 2 _Install Flange Nut. 3 Tighten Flange Nut/Bolt. 4 Place wire in Ground Lug channe[and tighten set screw to.complete assembly. *Wire should be sized in accordance with.the National Electrical Code,-NFPA 70;Section 690.45,and a minimum of 1/4"clearance required between-bare copper wire and aluminum. wog t- Driil.hole per.grounding lug manufacturers r�. .$0 specifications In the upslope part'of RockAt Coupling- far attaching grounding.iug. Note:Deburr hole in Ground Lug and Rock-it Coupling prior to-installation. www.ecofastensolarcom info@ecofastensolaccom 877-859-3947 6 ROCK-IT CLIP S.S inSTaLL 'e �A -.-2`Mhfrom 1 +encdon Aor 1 a 6h :4xf i<5 yc;y 1= Locate all.parts -Locate the Rock It.Clip SS,micro-inverter/power optimizer,and the section of the module frame in which you will be mounting the micro-inverter/power optimizer. See fig.A for acceptable mounting locations. 2.Install the Rock-it Clip SS • Slide the Rock-it Clip SS onto the lip of the module frame. • Slide the micro-inverter/power optimizer into the opposite lip of the Rock-It Clip SS. • Tighten the bolt to 150 in-lb minumum to.clamp the Rock-it Clip SS to the module frame and the micro-invertee/power optimizer to the Rock-it Clip SS. • .Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power optimizer flange is tight against the clip flange to avoid rotation during tightening. ROCK-IT CLIP 2.0 inSTaLL Inverter Flange Module Frame Rock-It Clip 2.0 1 Locate all parts -Locate the Rock-It Clip 2.0,micro-inverter/power optimizer,and the section of the module frame in which you Will be mounting the micro-inverter/power optimizer. 2.Install the Rock-it Clip 2.0(See below detail) • Slide the Rock-It Clip 2.0 onto the lip of the micro-inverter/power optimizer. • Slide the micro-inverter/power optimizer into the opposite lip of the module frame. • Tighten the,bolt to 150 in-lb.to clamp the Rock-It Clip 2.0 to the module frame and the micro-inverter/power optimizer to the Rock-It Clip 2.0. • Ensure that.the lip on the clip is tight against.the frame and that the micro-inverter/power optimizer-flange is tight against the clip flange to avoid rotation during tightening. www.ecofastensolarcom info@ecofastensolar.com 877=859-3947 7 Snow Load 0-20 psf Modules in Landscape_ Wind Speed Exposure 2:12<Roof Pitch<.6:12 7:12<Roof Pitch<12:12. ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3. B 159 93 59 85 mph 110 mph C 114 67 42 ' 88 88 D 96 56 35 91• 74' 74' B 146 85 54 90 mph 115 mph C 104 .61 38 98 80 80 D 88 51 32 83- 68 68 B 123 .72 45 .95 95 100 mph 125 mph C 88 51 32' .83- 68 68'- D 74 43 27. .70. 57 57. B 98 57 36 93- 76 76 110 mph 140 mph C 70 41- 26 66 54 54 D 59 34 22 56 46 46 B 85 50 31 81 66 66 920 mph 150 mph . C 61- 36 22. 58- 47 47 D 51 30 19 49 40 40 _] Notes: Spacing Governed by Snow Load 1.)Values in above table represent the.maximum allowable.spacing in fiches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing .2.)Maximum allowed spacing approved'by EcoFasten Solar is 72' 3.)Maximum allowed standoff capcity=647#(per testing results) 4.)includes additional factor of safety.of 1.5 for lag,pullout capacity 5.)Values based on maximum module width of 40" 6.)Based on Risk Category 11(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment-factors are set to 1.No site specific engineering is included in this table Snow Load 0-20 psf Wind Speed Exposure 2:12<Roof Pitch<6A2 1 7:12<Roof Pitch 4 E12'12ASCE7-05 ASCE7-10 Cate o Zone 1 Zone 2 - Zone 3 Zone.1 Zone 2 B163-- 33 _85 mph 110 mph C 65 38 24 61 50 D 55 32 20� 52 42 B 83 _ _ 49 30 90 mph 115 mph C 59 35 22 56 46 46 D. 50 _ 29 18. 47 .38 38 70_,._. _41 26 54 54 100 mph 125 mph C 50 29 18 47 39 39 D 42 _ . :-- 26 _ 1 .. _ iA ,__ 45_._.._..= 32 32_ B 56 33 20 53 43 43 110 mph. 140 mph C 40 23 14 38 31 31 D 34 19 12 32 26 26 _ - - - - B_ 49 28 'f 8'- __46___! 46:i'd 37' . 37 120 mph 150 mph C 35 20 12 33 27 27 D 29. 17. 10 28 22 22 Notes: ®Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFmten-Solar standoff 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" 3.)Maximum allowed standoff capcity=547#.(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module length of 70" 6.)_Based on-Risk-Category it(ASCE 7-10)structures less than 30 feet In height 7.)All adjustment factors are set to 1..No site specific engineering is Included in this table www.ecofastensolarcom info@ecofastensolarcom 877-859-3947 8 { r Snow Load 21-30 psf Modules in Landscape 'Wind Speed Exposure 2:12,<Roof Pitch 4-6:12 7:12<Roof Pitch<12:12 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone-3 Zone 1 Zone'2 Zone 3 . B 93 59 .85 mph 110 mph -C 67. 42- D 96 56 35 B 85 54 90 mph 115.mph C 104 61 38 D 88 51- 32 B 72 45 100 mph 125 mph C. 88 51 32 D 74 43 27 57 57 B 98 57 36 110 mph 140 mph C 70 41 26 66 -54 54 D 59 34 22 56 46 46 B• 85 .50 31- 66 66 120 mph 150 mph C 61 36 22 58 47 47 D 51 30 .19 49 40 40 Notes: Spacing-Govemed by-Snow Load 1.)Values In above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" 3.)Maximum allowed standoff capcity=.547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module width of 40" 6:)Based on Risk-Category II(ASCE 7-10)structures less than 30 feet In height 7.)All adjustment factors are set to 1.No site specific engineering Is Included in this table Snow Load 21-30 psf Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch_<12:12 ASCE 7-05'ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2. -Zone 3 85 mph 110 mph C 65 38 24 .-D 55 Y32 2Q B 49 30 90 mph 115 mph C 59 35 22 D 50 29 18 38 38 100 mph • : 125 mph C 50 29 18 39s 539 s. D 42 26 ^_ 5 A0" ' B 56 33 20 110 mph 140 mph C 40 23 14 38 31 3.1 D 34 19 12 32 26 26 - - B— - — - 49 -37-- 120 mph 150 mph C 35 20 12 33 27 27 D 29 17 10 28 22 .22 Notes: —Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" 3.)Maximum allowed-standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a.maximum module length of 70" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is included in this table www.ecofastensolarcom info@ecofastensolar.com 877-859-3947 9 + Y Snow'Load 31-40 psf Modules in Landscape Wind Speed Exposure 1 2:12.<Roof Pitch<6:12 .7:12<Roof Pitch.<12:12. ASCE 7-05 ASCE 7-10' Category Zone 1 Zone 2 Zone 3 Zonal, Zone 2 Zone 3 B 59 . 85 mph-' 110 mph. C 67 42 .. D 56 35 B 54 90 mph 115.mph C 61 38 D 51 32 B . 45 100 mph 125 mph C 51 32 D 74 -43- . 27. B .57' 36 110 mph 140 mph C 70 41 26 D 59 34 -22 46 46. B 50 "31 120 mph 150 mph' . C 6.1 '36 .22 47 47 ' D .51 30 . .19 .4$ . 40. . .40. Notes: Spacing Governed by Snow Load 1.)Values In above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff. however the designer must round down to meet appropriate rafter spacing 2:).Maximum allowed spacing approved by EcoFasten Solar is 72" 3.)'Maximum allowed standoff capoity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout,capacity 5.)Values based on a maximum module width of 4(" 6.)Based on Risk Category 11(ASCE 7-10)structures less than 30 feet in height - 7.)All adjustment factors are'set to 1.No site specific engineering is included In this table Snow Load 31-40 psf Wind Speed Exposure 2:12.<Roof Pitch<.6:12 7:12<Roof Pitch<12:12 ASCE 7-05.ASCE.7-10 Category Zone.1 Zone -Zone 3 Zone-1 Zone 2 . Zone 3 85 mph 110 mph C 20 B N449 30 Y 90.mph 115 mph C 35, 22 D _29 18 AT 100 mph 125 mph C 29 18- B 33 20 . 110 mph 140 mph. C 40. 23 14 D 34 19 12 26 26 _49. 28 1 " 120 mph '160 mph C 35 `20 i2 D 29 17 10 28:` 22 22 Notes: Spacing Governed by Snow Load- 1.}Values In,above table:represent the maximum allowable spacing In.inches for pullout.forces only.on EcoFasten Solar,standoft . 2:)Maximum,allowed spacing approved by EcoFasten Solar Is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.6 for lag pullout capacity 5.)Values.based on.a maximum module length of 70" 6.)Based on Risk Category it(ASCE 7-10)structures-less than'30 feet in'height 7.)All adjustment factors are set to 1.No site specific engineering is'included in.this table www.ecofastensolar.com info@ecofastensolar.com 877=859-3947 10'. Snow Load 41-50-psf Modules in Landscape Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 59 . 85 mph 110 mph C 42 D 56 35 B 54 90 mph 115.mph C 61 38 D 51 32 B 45. 100 mph 125 mph C 51 32. D 43 27 B 57 36 110 mph 140 mph C 41 26 D 59 34 22 46 46 B 50 31 120 mph 150 mph C 61 36 22 47 47 D 51 30. 19 49 40 40 Notes: Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing In Inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.),Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a-maximum module width of 40" 6.)Based on Risk Category If(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is included in this table Snow Load 41-50 psf Wind Speed Exposure 2:12<Roof Pitch<6:12 1 7:12<Roof Pitch<12,12 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 ----- B 33 85 mph 110 mph C I 38 24 D 32_ 20 B 30 90 mph 115 mph C. 35 22 D 29 18 - B - 26 100 mph 125 mph C 29 18 a 26 15 B 33 20 110 mph 140 mph C 23 14 D 19 12 B - 28 -18 120 mph 150 mph C 35 20 12 D 29 17 10 22 22 Notes: ®Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.)Maximum allowed spacing approved by EcoFasten Solar Is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module length of 70" 6.)Based on Risk Category II(ASCE 7-10)structures less-than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is Included in this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 11 Snow Load 51-60 psf Modules in Landscape Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 ASCE 7-05 ASCE 7-10. Cate o Zone 1 Zane 2 Zone 3 Zone 1 Zone 2 Zone 3 B 85 mph 110 mph C 42 D 35 B 54 90 mph 115 mph C 38 D 51 32 B 45 100 mph 125 mph C 51 32 D 43 27 B 36 110 mph 140 mph C 41 26 D 34 22 B 50 31 , 120 mph 150 mph C 36 22 D 51 30 '19 Notes: Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in Inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafter spacing 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1:5 for lag pullout capacity 5.)Values based on a-maximum module width of 40" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to-1.No site specific engineering is Included in this table Snow Load 51-60. psf Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<-Roof Pitch<12:12. ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 .Zone 2 Zone 3 85 mph 110 mph C 24 D S2 20 B 30 90 mph 115 mph C 22 D 29 _ 18 B -26 100 mph 125 mph C 29. 18 D' 26 15 B 20 110 mph 140 mph C 23 14 D 19 12 - - - -B - 28 18 — 120 mph 150 mph C 20 12 D 28 17 10 Notes: ®Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing In Inches for pullout forces only on EcoFasten Solar standoff 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module length of 70" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering Is included in this table www.ecofastensolar.com info@ecofastensolar,com 877-859-3947 12 GrounoinG nFormaTion The rail-free Rock-It System maybe used to mount and ground PV modules that comply with UL 1703,only when that specific module has been evaluated for mounting and grounding,in compliance with the included installation instructions. Note;Grounding lug must be visible to inspectors from the entire perimeter of the PV array. Multiple Use Grounding Pins Grounding pins within the Mid-Clamp are multiple use bonding/grounding devices.Modules will need to be adjusted if the Mid-'Clamps are loosened to ensure there is"new metal to pierce into upon retightening. Grounding Method Rock-It 4.0 Mount bonds N-S rows of.modules Rock-it 4.0 Coupling bonds E-W rows of modules Rock-t Array Skirt bonds E-W along-the entire array when installed One Burndy CL50-ITN ground lug is required per PV array,limited to 300 modules placed-in either portrait or landscape orientation. BonD1nG AssemBLy anD BonainG PATH Bond Path Grounding Lug Roble (GEroundirg Integrated Bonding' � Cate'�rcbrlEGC: gtn'Wtota.th Sze 1 ® Rock-It Coupling I .t'Rotk-it Moats. ®Rock4,Array Skirt Bond Path Bond Path 49j Grounding Lug '� *'Gramclinglug Eqularnem.GrounMg _ pn /^ CaMuaer(EGn /-' C�oaduC IEGC}.1� gaarallr tocartft graani ynxcitytorunh B.omd o Rak•I[Coupling 0 Rock-Itcoupong { s Rock-It Mount s'Radcat Mount ..�.Rock-it Array Skirt. Rock-It Array Skirt www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 13 i THermaL EXPansion anD BonDInG A thermal expansion gap is required per each continuous 40'length.of modules. -- Bond Path Omit a coupling and leave a 2"gap in ® Grounding lug the Rock-It Array Skirt and also between --Equipment r� the modules at that point. WZ1Y"effr'j' s Rock-It Coupling ■ Rock-it Mount .Rock-It Array Skirt " Brao<eTsPaonG Portrait Orientation Landscape Orientation I i I i j Maximum east/west bracket spacing is 48"OC. Max east/west bracket spacing is 72"OC. 32mm modules:Max east/west bracket spacing.is 48"OC- Spacing may vary depending upon project specific structural requirements;i.e.high snow and wind load areas may require lesser spacing E-W than the maximum. sTaGGereD LaYOUT CanTILeVer anD .OFi=Se T Staggered Mounting Points a`Centllever ®Rock-It Mount ®Rock-It Coupling Cantilever. Maximum cantilever is 1/3 bracket spacing. For portrait orientation installations,check layout prior to installing. The array layout instructions in this installation manual offer a general overview of layout. Periodically,due to a variety of Offset:Offset from all roof edges depends on wind speed,snow .factors(roof obstacles,shading,etc.)other layouts are required. loads,local fire and building codes per location www.ecofastensolarcom info@ecofastensolarcom 877-859-3947 14 ROCK--IT SYSTeM 4.0 SYSTem speclFicaTlons Max No.of Panels .300 Modules per ground lug Materials 300 Series Stainless, 6000 Series Aluminum Max System Voltage 100OVDC Coating- SlackAndodization/Mill Finish Class A Fire Rating With UL1703Type I Rated Lug Specifications Bumcly CL50-ITN Ground Lug Modules,see note below. (UL Listing#KDER E9999) Leveling Range 3-4" Ground Wire 14AWG-4AWG Copper Per above Lug spec. Ground Wire Rock-it Slide Comp Range 3' Max Module Size 64.96'(1*650mm)x Rock-It Slide Tile 7' 39.65'(992mm)X 2"(50mm) Min/Max Roof Slope 1/2.12/1212 Max Downibrce/UpIfft Rating 45 PSF Max Anchor Spacing(35=140mm) 72' Rock-it Mount Load Rating 547lbs with SIngId 5/16'Lag 3.0 Max Anchor Spacing(32mm) 48' Safety Factor Skirt Box(ITY 6 units Slide Fastening Hole 5/16'cliameter Mount Box CITY 12 units Module Cantilever Maximum cantilever Is 1/3 Rock-it Slide Box CITY 50 units bracket spacing. Coupling Box QTY 12 units —[Warranty 20 Year Material and Workman- ship. Codes:National-Electric Code,ANSVNFPA 70,NEC 250,NEC 690,IRC,IBC Standards:UL 2701 First Edition,UL 1703 EWli"M.WAf !Zx r UMI4CODEI44T_Q2�2 16 CONFcFaSIV UL2703 WAD of^FeSYCtrSNUticv The Ecol'asten Solar Rock-it System Is a rooftop PV racking system consisting of 6000'Series,Aluminum and 300 Series, Stainless Steel components.the Rock-it System Includes the rack components but does not include the PV panels, inverters or electrical components.The PV modules to be used with Rock-it shall be certified under UL 1703.The system shall be used on steep slope roofs mounted over a Class Afire rated roofing material and attached to the roof, structure uslng:5/1 6"diameter,-minimum 4"long 300 series Stainless Steel lag bolts with minimum thread embedment depth of 2 1/2"into the roof structure. Periodic re-inspection for loose components The system is subject to re-inspection as required by the PV module manufacturer or,by the Authority.Having Jurisdiction.Re-inspection,as required,-should include evaluation of any loose components or loose fasteners.All loose components and fasteners should be secured In accordance with these instructions.The system should also'be evaluated for any evidence of corrosion.Any corrosion should be removed.-Any affected part should be cleaned or replaced In accordance with these instructions. A _uXoFasten Solar V www.ecofastensolar.com lhfo@ecofastensolar.com 877,859-3947 15 FeaTures • New and improved design • North-South adjustability • Fastest,easiest to level system on the market. • Only one tool required.(1/2°deep well socket) • Integrated electrical bonding Vertical adjustment of Y-4" • SIMPLE-only 4 components EvaWaTe.D, comPaTIBLe MODULes Model Type(x"used to Downward Pressure Upward Pressure Down-siopeDesf� ModiteMerufacturer Indlcetevarlahletest ModuleCimenslms(mm) ModuleDlmendmsQn)• MegmumUemp Design Load Lost) Design Load(pso Load(pst) ywng(In) T1ina Solar TSM-xxx4"5.08 1640 x 992 x 40 6495"x39.051'•L57" - 33.3. 33.3 20 72- ConadlanSolar CS613-v" 1698x922x4l) 6448"X38.66"W17" 33.3 33-9 20 .72 Canadlan Solar C56P-xxxP 1638 x 982 x 40 64.5'W8.7"x1.57' 33.3 33.3. 20 72 JinkoSolar XM)06(P.60 1650'x992'x40 64961149.05"x1.57" 30 30- 20 .72 JlnkaSolar JKMWM-60 1650x992x40 649611)G9.05'..1"7" 30. 30 .20' 72 JlnkoSoler JKMwoa'P•60 1650x992x40 6496"x39.05"xL57" 30 30 20 72. JlnkoSolar Jlwxx)mM-60 1650x992x40 6496"x39.051'xL57" 30 30 .20 72 .Ylri0iSolar YL2AP-29b 1650 x990 x40 64.96'48S7'J.57" 30 30 20-- 72' LGElcetronlcs LG39CtdGB9 1640x1000x35 645714439.97'a.88" 30 30 20 72 LG Elcetronles LG30DN1K-G4 1640 x 2000 x 40 64.5713W.3T.'xL57" 30 30R.220. 72- AxltecSolar AGxxxM/156.60S 1640*992 x4C 645"x39.06NUB" 30. 30 48, RECOM RCM-2xx-6MB 1640x992x35 6456"x39A5:'a.37" 30 30 72 Sllfab SLA7xxP 1650 x 990 x 38 6496'W8S7&49" 30 30 72. Solarla PowerJQ xxxR-BX 1621 x 1056 x 40 69.99"x41.53"a.57" 30 30- 48 Hanwha--QC?Jls• C,PROG42xx 1670 x 1000 x 32' 65.75'W19.37'xL25" '30 30. 48 Hanwha-QCells• 0,PROG42xx 1670x10DOx32 . 65.75"x39.97'xL2S" 30 30' 73 Sunpreme GxB-3xxT 1670x997x40. 65.75'4dl9.25"xL57" 30 30 .20 .49 REC REGxxx-6MB 1675 x997x38 65.94"x39.259r1.5" 20 20- 20 '72- REC REC-xxx-GMB 1675 x997 x30 65.94109.25"xL5" so- 30 20 48 SolarWorld SW xxx Mono Black 1675 x961 x33 65.95"x37.8"WV 20 20 20'. 72 5012rWorid SW xxx Mona Bleck 1675x961x93 65.95"x37.WxL30" 30 30 20 48- 'Hanwha 0-Celis 32mm modules to be used with special order Rock-It System components.Call for details. Pao aCOd EcoFasten-Solar www.ecofastensolarcom info@ecofastens6lar.com 877-859-'3947 16 ( C Cut Sheet Rock U-4.0-Mount 1. Installation to be completed In.accordance with-manufacturers written specifications,and installation instructions. 2.. See spec sheet or contact manufacturer for detailed material,finishes,and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change-without notice. 0 3.171n , 80.54mm -- _ [ ] _ 2:50in 63.50mm] I ` 771-1 1-;1; 2.02in 2.1.4in 2:34in- [51.38mm] [54.37mm] 59.36mm 32mm �— 35mm 40mm I�PII�1E r j~• 4741 W Polk Street Ste.4 UARDS`1, n 1a�r' Phoenix,AZ 85043 Toll Free Phone 1.888.766.4273 Toll Free Phone 1.877.859.3947 Material:See Spec Sheet Toll Free Fax 1.888.766.9994 Toll Free Fax 1.888.766.9994 -- -- Scale: 1:2 6/28/2017 ASG: - EFS: x Data Sheet Enphase Networking Enphase The Enphase IQ.Combiner 3" with Enphase IQ EnvoyT" consolidates interconnection IQCombiner 3 equipment into a-single enclosure and (X-1Q-AM1-24073) streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four- 2-pole input circuits and Eaton BR series busbar assembly. Smart s� ills Includes IQ Envoy for communication and control Flexible networking supports Wi-Fi, LEthernet,or cellular Optional AC.receptacle available for PLC bridge Provides-production metering and optional consumption monitoring — t d) Simple I! ? �,.E_• Reduced size from previous combiner �� " roe' " • A Centered mounting brackets support single �4 stud mounting. Supports back and side conduit entry _., ,. Up to four2=pole branch circuits for240 VAC plug-in breakers(not included) s 80 A total PV or storage branch circuits Reliable • Durable NRTL-certifiedNEMA type . 3R enclosure • Five-year warranty o L UL listed FISTED n E N P H A S E. To learn more about Enphase offerings,visit enphase.com �./ Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy'"printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). ACCESSORIES and REPLACEMENT PARTS (not included,order separately) Enphase Mobile Connect"' CELLMODEI:i-03(9G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEI:`-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEl,14.11(4G based LTE-Ivi/5-yeardata plan) where there.is adequate cellular service in the installation area.) Consumption Monitoring*CT CT-200-SPLIT Split core current transformers enable whole home consumption metering(+/-2.5%). Circuit Breakers Supports Eaton BR210,BR215,BP,220,BR230,BR240,BR250,and BR260 circuit breakers. BRK-1 OA-2-240 Circuit breaker,2 pole,1 OA,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.continuous current rating(input from PV) 64 A Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included Production P,4etering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions(1':`Y H%:Dl 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). Weight 7.5 kg(16.5 Ibs) Ambient-temperature range -400 C to+460 C(-401 to 1151 F) Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) Cellular Optional,CELLMODEM-01 (3G)or CELLMODEM-03(4G) or CELLMODEM-M1(4G based LTE-M) (not included) COMPLIANCE Compliance,Combiner UL 1741 CAN/CSA C22.2 No.107.1 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Compliance,IO Envoy UL 60601-1/CANCSA 22.2 No.61010-1 *Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings,visit enphase.com ©2018 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. G N H A C 2018-09-13 `� 9 i Installation Manual Soltection RJ=1 Rooftop SoDar Junction Box Fiashing Unit For.Composition/Asphalt Shingle Roofs v. Manufactured by:- Soltection: a division of Vynckier Enclosure Systems, Inc. 271 McCarty Street Houston,TX 77029 1-866-227-0577: www.soltection.com Soltection RJ-1 Installation Manual Page 1 � r TABLE OF CONTENTS ONS7ALLA710H RNSTRUCTIONS Contents IMPORTANT SAFETY INSTRUCTIONS........................................................................................................................4 SAFETYWARNINGS & CAUTIONS ..........................................................................................................................4 ELECTRICALPRECAUTIONS....................................................................................................................................5 MECHANICALPRECAUTIONS.................................................................................................................................. 5 PRODUCTINFORMATION.............................................................................................................................................. 6 OVERVIEW...................................................................................................................................................................... 6 PREP & PLACEMENT...................................................................................................................................................... 7 REQUIREDTOOLS.......................................................................................................................................................7 PRODUCTPLACEMENT..............................................................................................................................................7 SPECIFICATIONS .......................................................................................................................................................... 11 MECHANICAL/ ELECTRICAL................................................................................................................................:.. 11 TORQUERATINGS..................................................................................................................................................... 11 WARRANTIES: Seller warrants to Buyer that products and any services furnished hereunder will be free from defects in material,workmanship and title and will be of the kind and quality specified in Seller's written quotation.The foregoing shall apply only to failures to meet said warranties(excluding any defects in title)which appear within two years from the date of shipment hereunder. The conditions of any tests shall be mutually agreed upon and Seller shall be notified of, and may be represented at, all tests that may be made.The warranties and remedies set forth herein are conditioned upon(a)proper storage, installation, use and maintenance, and conformance with any applicable recommendations of Seller and (b) Buyer promptly notifying Seller of any defects and, if required, promptly making the product available for correction. If any product of service fails to meet the foregoing warranties(except title), Seller shall thereupon correct any such failure either at its option, (i)by repairing any defective or damaged part or parts of the products, or(ii)by making available, F.O.B. Seller's plant or other point of shipment, any necessary repaired or replacement parts.Where a failure cannot be corrected by Seller's reasonable efforts,the parties will negotiate an equitable adjustment in price. The preceding paragraph sets forth the exclusive remedies for claims (except as to title) based on defect in or failure of products or services;whether the claim is in contract, indemnity,warranty, tort(including Seller's negligence), strict liability or otherwise and however instituted. Upon the expiration of the warranty period, all such liability shall terminate and Buyer shall have a reasonable time,within thirty days after the warranty period,to give written notice of any defects which appeared during the warranty period. Except as set forth in Article 2, "Patents," the foregoing warranties are exclusive and in lieu of all other warranties, whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY. Seller does not warrant any products or services of others which Buyer has designated. www.soltection.com Soltection RJ-1 Installation Manual Page 3 v IMPORTANT SAFETY INSTRUCTIONS . D ALL INSTRUCTIONS ; SAFETY WARNINGS PRIOR TO INSTALLATION NOTE: SAVE THESE INSTRUCTIONS- This manual contains important instructions that shall be followed during installation and maintenance of the Soltection RJ-1 rooftop junction box with flashing. LETHAL VOLTAGES ARE PRESENT DURING THE INSTALLATION, OPERATION AND SERVICE-OF THIS EQUIPMENT. PROPER PRECAUTIONS MUST BETAKEN AT ALL TIMES TO ENSURE THE SAFETY OF THE SERVICE PERSONNEL. . • SAFETY WARNINGS & CAUTIONS ■ Only qualified personnel or licensed electricians should install this product and the instructions herein are provided for those individual(s)only. ■ To reduce the risk of electric shock, injury, or death, all electrical wiring and connections, must be performed by qualified personnel. ■ Lethal voltages are present during the installation, operation, and servicing of this equipment. Proper precautions must be taken at all times to ensure the safety of the service personnel. ■ Follow' state,and federal Occupational Safety and Health Administration (OSHA).guidelines and regulations when installing this product. ■ Utilize proper Personal Protective Equipment(PPE)as required per national and local regulations as well as for installation best practices. ■ Install this apparatus in accordance with,ANSI/NFPA 70, National Electrical Code (NEC)..Follow_all national or local electrical codes. ■ Install, operate,. and use this product in a manner consistent with the instructions provided..Failure to. follow the procedures indicated may result in roof leaks, property damage, or consequential damage. www.soltection.com Soltection RJ-1 Installation Manual Page 4. s i ' CAUTION ELECTRICAL PRECAUTIONS ■ Ensure all electrical conductors are at zero voltage potential=before installing or servicing this unit. • Never break contact on a circuit without using.the appropriate disconnect device. ■ Follow established lockout and tagout procedures for all electrical conductors prior to servicing. ■ Beware of power.lines in the vicinity of the roof,.where inadvertent.contact may result in electrocution,. .personal injury, or death. When.disconnecting source or supply circuits,provide.sufficient time.as stated in the.power electronics manufacturers instruction manual in.order to ensure discharge of all conductors in.the circuit. Always verify the-integrity and proper installation of the electrical components prior to energizing electrical. circuits. ■ Non-metallic enclosures do-not provide grounding means between- conduit connections. The use of grounding hubs and jumper wires are required. ■ -Grounding must be sized per NEC requirements, and is the responsibility of the installer. MECHANICAL PRECAUTIONS ■ When drilling into an attic.space, ensure that electrical wires, mechanical obstructions, or potential electrical hazards are.removed from the vicinity and-direction of the drill. ■ Do not -install if-the -roof is wet, frosted, or covered by ice or snow. ■ If any-part of this product becomes damaged, • remove and'destroy-the entirety of the unit. Failure to do so may result-in.fire, property damage, personal injury, electrocution, or death. ■ Do not use the product to anchor fall protection equipment. www.soltection.com Soltection RJ-1 Installation Manual Page-5 PRODUCT INFORMATION OVERVIEW ■ The Soltection RJ-1 Residential Rooftop.Junction Box is a flashed roof penetration designed to protect electrical conductors entering the rooftop/attic. It is made of a high-strength UV-resistant and UV- stabilized polymeric material. ■ The RJ-1 enclosures comes fully equipped with a slotted DIN rail mounted inside the enclosure designed for mounting of DIN rail accessories, such as terminal blocks. ■ A four position ground bar is also provided as a means to form a bond between the solar array mounted on the roof and the building. CORNER SCREWS MOLDED COVER PLASTIC SCREW FOR GROUND BAR AFFIXING DIN RAIL GROUND BAR o 0 00 0 MOLDED BASE \—DIN RAIL www.soltection.com Soltection R1-1 Installation Manual Page 6 PREP & PLACEMENT REQUIRED TOOLS ✓ Shingle Ripper Bar ✓ #2 Phillips Screwdriver ✓ Lumber Crayon ✓ Hole Saw or Spade Bit ✓ Uni-Bit ✓ Roofing.Sealant ✓ Utility Knife RAFTER,-... A PRODUCT PLACEMENT T. • Identify the location and placement of the. _ flashing on the roof as shown. The product may be mounted beneath the array or adjacent to the array. - - �y • yk: .v DO NOT LOCATE THE PRODUCT DIRECTLY -OVER A RAFTER TO -ENSURE THE RAFTER DOES NOT INTERFERE WITH THE WIRING Remove template from packaging ENTRY INTO THE.ATTIC and use in Step 2 STEP 1 www.soltection.com Soltection RJ-1 Installation Manual Page 7. a � k.• Via; i�w Position the top edge of the template 1/2" Trace and continue using a lumber crayon to the above the 1st course of shingle as shown. bottom of the 2nd course. Cut along lines and remove shingles. STEP 2 STEP 3 RECCOMENDED LOCATION FOR r CONDUIT ENTRY INTO ROOF RAISED AREA Itv \. f MOLDED BASE Remove any roofing nails beneath the 1-st, 2nd,or DRILL PILOT HOLE 3rd course of the that obstructs the position of Slide RJ-1 Junction box into place where you the roof flashing. cut shingle template.The image above shows STEP 4 where you will drill in the next step STEP 5 www.soltection.com Soltection RJ-1 Installation Manual Page 8 1 •I �J DRILL PILOT HOLE Slide RJ-1 Junction box into location where you cut shingle template. Using 1/4"drill bit drill Remove box&see pilot hole in roof. through box& Roof simultaneously(for location STEP 7 see step 5) STEP 6 P Using the pilot hole, Drill through the roof,the Reinstall box&using the pilot hole again,drill diameter necessary to ensure that it will the diameter necessary to ensure that It will accomodate the appropriate conduit fitting accomodate the appropriate conduit fitting STEP 8 STEP 9 www.soltection.com Soltection 11J-1 Installation Manual Page 9 � L K� 9 / { i Remove RJ-1,flip it over,wipe it clean&apply Reinstall Unit. Use the two supplied Decking a bead of roofing sealant to the underside of the Screws to mount the flashing to the roof. flashing unit. Ensure that it's placed in the Torque to the specification indicated in the "Upside-down U"Shape to support engress specifications. Refer to Table TZ(page 10)for water protection,AS SHOWN. the proper tightening torques. STEP 10 STEP 11 POPULATE RJ-1 • Populate the RJ-1 unit using the appropriate wire connectors,terminal blocks, or other necessary components. iv • Ensure that the components installed are rated for and are suitable for the intended purpose. • The RJA unit is provided with multiple standoffs which can accommodate accessories to be mounted. Step 11. A Install the cover onto the top of the enclosure. Tighten 4 cover screws to the Torque value indicated in Table T3(see page 10) STEP 12 www.soltection.com 5ootection R.1-1 Installation Manual Page 10- SPECIFICATIONS MECHANICAL/ .ELECTRICAL ■ Product Certifications: UL508A ■ Enclosure Rating:Type.4X. ■ Attic Conduit Pass Through Connector Size Range: 1/2"—.1" ■ Max.Side Wall Conduit Size: 1" ■ Maximum Current:'N/A • Maximum Voltage: N/A ■ Ambient Operating Temperature: -35C to 75C TORQUE RATINGS Table T1: Ground Bar Connection, Wire Range:.#4 to#14, 4 Usable Connections MOO o - 0 0 0 'Wire Size Tightening Torque(lb- in 4-6 AWG. 35 8 AWG 30 10-14 AWG 25 Table T1 Table T2: Mounting Screw, Mounting to Decking, 2 Provided Tightening Torque (lb-in 15-20 Table TI Torque Values, Cover/Lid Screws , 4 Provided, Captive [:Tightening Torque (lb-in) 11 www.soltection.com Soltection RJ-1 Installation Manual Page 11 ■ TM soltection by vynckier Soltection is a division.of Vynckier Enclosure Systems, Inc. 271 McCarty Street Houston, TX 77029 1=866-227-0577 5 SYSTEM INFORMATION CLIMATIC& GEOGRAPHIC DESIGN CRITERIA TABLE momentum PLAN KEY MODULE HANWHA Q.PEAK DUO BLK-G6+ 340 R301.2(1) ( ) PV-1 COVER PAGE SOLAR INVERTER ENPHASE IQ7-60-2-US SPEED (MPH) 140 PV-1.1 ATTACHMENT DETAIL PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR RACKING ECOFASTEN ROCK-IT SYSTEM TOPOGRAPHIC EFFECTS B 325 HIGH STREET,METUCHEN,NJ 08840 PV-2 ROOF LAYOUT (732)902-6224 MOMENTUMSOLAR.COM PV-3 ELECTRICAL SYSTEM SIZE (DC) 8.5 KW SPECIAL WIND REGION NO PROFESSIONAL PV-3.1 ELECTRICAL CONT. LOCATION 28.2680180,-82.1763250 WIND BORNE DEBRIS ZONE 2 ENGINEERING PV-3.2 EQUIPMENT LABELS GENERAL NOTES: SEISMIC DESIGN CATEGORY C THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS CLIMATE ZONE 2A FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, 6TH EDITION 2017 WIND EXPOSURE CATETORY B FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 FLORIDA BUILDING CODE, 6TH EDITION 2017 FLORIDA FIRE PREVENTION CODE, NEC 2014 AND ALL LOCAL CODES & ORDINANCES. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. CEN�F'• •Ip 'i INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND HANWHA Q.PEAK DUO BLK-G6+ 340 NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. 340 WATT MODULE * 68.5" X 40.5" 1. 6" ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT '• ` t-/-;, (SEE DATASHEET) INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A STATE OF 6y PLUMBING PERMIT AND INSPECTION. ALL DESIGN, CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK :REGISTERED JUN_022020 2 2020 BILL OF MATERIALS ARCHITECT. FLORIDA STATE STATUTE 471.003(3) PROVIDES THAT LICENSED REVIEW DATE `'!1111 I 1 j I`'� ARCHITECTS ARE EXEMPTED FROM THE PROVISIONS OF CHAPTER 471 ENGINEERING CITY OF ZEPHYRHIL , MODULES 25 AND NOT PRECLUDED FROM PERFORMING ENGINEERING SERVICES FOR INTEGRATED PLAN EXAMINER INVERTERS 25 SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO BUILDINGS AND STRUCTURES. CLAMP ASSEMBLY 78 INVERTER PLACEMENT: I ALL WORK SHALL COMPLY WITH PREVAILING COUPLING ASSEMBLY 43 CODES FLORIDA BUILDING CODE, SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL BONDING CLIP 10 LOCATED ON THE BACK SIDE OF EACH MODULE. NATIONAL(�E�L�ECTRIC,•CODE,, SOLAR CONTRACTOR AND THE CITY d/OF ZEPHYRHILLS CAMERON CHRISTENSEN SKIRTS 14 STRUCTURAL STATEMENT: ORDINANCES CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 ENPHASE COMBINER BOX 1 CUSTOMER INFORMATION EATON 60A FUSIBLE AC THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY DISCONNECT 1 THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER MARGARET RATERING-MS50117 SIZES & DIMENSIONS CONFORM TO 6TH EDITION 2017 FLORIDA RESIDENTIAL CODE 7924 MERCHANTVILLE CIR 40A FUSES 2 FBC, Residential 2017 ZEPHYRHILLS, FL 33540 MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED FLORIDA CODE (813)426-2046 _ 35A BACKFEED BREAKER 1 REQUIREMENTS FOR THE DESIGN CRITERIA OF THE TOWN. TABLE R301 .2.1 .3 PV SYSTEM INFORMATION SYSTEM SIZE(DC):8.5 KW 25 MODULES: HANWHA Q.PEAK DUO WIND SPEED CONVERSIONSa BLK-G6+340 25 INVERTERS: ENPHASE IQ7-60-2-US Vint 110 115 120 130 140 150 160 170 180 190 200 PROJECT INFORMATION Vasd 85 89 93 101 108 116 124 132 139 147 155 INITIAL DATE: 5/27/2020 DESIGNER:SN For SI: 1 mile per hour = 0.447 m/s. REV: DATE: DESIGNER: REV: DATE: DESIGNER: a. Linear interpolation is permitted. COVER PAGE PV- 1 SEE ATTACHMENT SCHEDULE FOR MAXIMUM CANTILEVER 'ECOFASTEN'ROCK-IT 1. ALL WIND DESIGN CRITERIA ARE FOR LOW SLOPE ROOFS, GABLE AND HIP ROOFS COUPLING HIEN ATACT SYSTEM momentum CLAMP& 'ECOFASIEN''ROCK-IT SOLAR MODULE S C' A P CONSIDERED FROM AN ANGLE OF MIN.9.5° ( )TO MAX.45°(? )NOT TO EXCEED ATTACHMENT �g 30' MEAN ROOF HEIGHT ATTACHED WITH FASTENERS AS SPECIFIED BY THE ROOF MANUFACTURER. RAFTS SKRT PLYWOOD DECK,AID PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 325 HIGH STREET,METUCHEN,N]08840 2. SPAN TABLES ARE DERIVED FROM MECHANICAL LOAD TESTS PERFORMED BY THE SOLAR MODULE RAFTER (732)902-6224 MANUFACTURERS INDEPENDENT TESTING AGENCIES ON BEHALF OF THEI : MOMENTUMSOLAR.COM MANUFACTURER. PROFESSIONAL 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 ENGINEERING 4. ATTACHMENTS ARE MANUFACTURED BY ECOFASTEN SOLAR, PHOENIX,ARIZONA. GUTTE AND ALL ATTACHMENTS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURERS PRINTED INSTRUCTIONS. MINIMUM 5"SPACING TO GUTTER ROCK-IT TO RAFTER ATTACHMENT SPACING SCHEDULE ECOFASTEN SOLAR ROCK-IT 4.0 MOUNTING DETAIL *ALL MODULES TO BE INSTALLED IN LANDSCAPE ORIENTATION ECOFASTEN SOLAR ROCK-IT 4.0 RAIL-LESS MOUNTING SYSTEM ALL COMPONENTS SHALL BE AS MANUFACTURED BY'ECOFASTEN SOLAR'AD INTEGRATED WITH FLASHING,COUPLINGS AND ADJUSTABLE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURERS PRIED SPECFICATIONS. ONLY IN WIND ZONES OF 150MPH &UP. CLAMP ATTACHMENTS ULTIMATE ATTACHMENT DETAIL FOR SLOPED ROOF ZONE 1 ROOF ZONE 2&3 DESIGN MAX. SPAN/MAX. MAX. SPAN/MAX. COMP. SHINGLE ROOF Ii //1WIND ��// SPEED CANTILEVER CANTILEVER(MPH) ` ® �• �� /ice (INCHES) (INCHES) SEE ATTACHMENT SCHEDULE �, 10EgF •!�� i' 125 48"O.C./ 16"MAX. 32" O.C./12" MAX. FOR MAXIMUM CANTILEVER ` 4 130 48" O.C./ 16" MAX. 32"O.C./12"MAX. 'ECOFASIEN'SIMPLE(tP SOLAR MODULE 2 LAG H 140 48" O.C./16"MAX. 24" O.C./10"MAX. COUPLING DECK MOUNT W/ j 150 48"O.C./16"MAX. 24"O.C./8"MAX. CLAMP& BOLTS TO RAPIER DUSTING ROOF MEMBRANE f ' S / 4.1 160 48"O.C./ 12"MAX. 22"O.C./8"MAX. ATTACHMENT RAFTER '�O , STATE OF __________________________ i 'ECOFASTEN'SKRT 170 48" O.C./ 12" MAX. 19"O.C./8" MAX. TABLE REFLECTS ATTACHMENT SPACINGS THAT EXCEED MANUFACTURERS RAFTER SPECIFICATIONS FOR WIND LOADS AS PER ASCE 07-10. RISK CATEGORY II SOLAR MODULE I I I I 1 TOPOGRAPHIC EFFECTS B,C, &D AND ROOF WIND ZONES 1,2,&3. ROOF ZONES 2&3 ARE WITHIN 48"OF ANY OUTER EDGE, HIP, RIDGE, OR GUTTER LINE FOR STRUCTURES 30'-0" OR LESS MEAN ROOF HEIGHT. GUTTER GUTTER © ® ® ® ALL COMPONENTS SHALL BE AS MANUFACTURED BY'ECOFASTEN SOLAR'AND DETAILED IN STRICT COMPLIANCE WITH MANUFACTURERS PRINTED SPECIFICATIONS. LU GUTTE SOLAR CONTRACTOR Q ® 10 10 ® w i ATTACHMENT DETAIL FOR \Q ® LOW-SLOPED ROOF CAMERON OM UM SOLAR LASEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MOMENTUM ® RIDGE RIDGE ® ®© 0 ® MINIMUM 5"SPACING TO GUTTER 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 (2) CUSTOMER INFORMATION ECOFASTEN SOLAR ROCK-IT 4.0 MOUNTING DETAIL 'ECOFASIEN'ROCK-IT y/q ECOFASTEN SOLAR ROCK-IT 4.0 RAIL-LESS MOUNTING SYSTEM ATACHMENT SYSTEM MARGARET RATERING-MS50117 W INTEGRATED WITH FLASHING,COUPLINGS AND ADJUSTABLE Y 'ECOFASTEN'EF-MR-SS-NDD 7924 MERCHANTVILLE CIR ® O O CLAMP ATTACHMENTS ATTACHMENT AND FLASHING W/ S( MODULE ZEPHYRHILLS, FL 33540 8)QDf15 FASTENERS TO DECK (813)426-2046 EXISTING ROOF © ® GUTTER ® GUTTER © 'ECOFASTEN'SKIRT MEMBRANE,DECK PV SYSTEM INFORMATION SYSTEM SIZE(DC):8.5 KW 25 MODULES: HANWHA Q.PEAK DUO ROOF WIND ZONES AS PER IRC R301.2(7) BLK-G6+340 MAXIMUM SOLAR ARRAY ELEVATION:4.25•' ROOF ZONES 2&3 ARE 48" FROM OUTER ROOF EDGES, 25 INVERTERS: ENPHASE IQ7-60-2-US RIDGES, HIPS, RAKES,AND GUTTER EDGES FOR STRUCTURES rMAXIMUM CLAMP ATTACHMENT SPACING:48" BELOW 30'-0" MEAN ROOF HT. COUPLING CLAMP PROJECT INFORMATION INITIAL DATE: 5/27/2020 DESIGNER:SN SOLID BLOCKING ALL COMPONENTS SHALL BE AS MANUFACTURED BY'ECOFASTEN SOLAR'AND REV: DATE: DESIGNER: BETWEEN JOISTS INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURERS PRINTED SPECIFICATIONS. REV: DATE: DESIGNER: O ')w z W ATTACHMENT DETAIL FOR ROOFS ATTACHMENT DETAIL AREA WHERE RAFTERS NOT AVAILABLE PV- 1 ■ 1 SCALE: 1/8" = V-O" ROOF PANEL COUNT TILT AZIMUTH SHADING R1 17 25° 180' 99% momentum R2 8 25° 270' 100% SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 325 HIGH STREET,METUCHEN,NJ 08840 (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING AC CB DISC M LJ __ MSP ELECTRICAL EQUIPMENT DRIVEWAY DRIV 13 22 rn 8'-2" ,�� Q►..•.'...� ���� 0 * rn � � STA E F 4 \ O 0 ( n m ))Iill''' c ( o Ia IA I L4 __ 4'-8" Do I I ❑ SOLAR CONTRACTOR SOLAR INSTALLER NOTES: CAMERON CHRISTENSEN R1 -0" R2 HAS HORIZONTAL RAFTERS CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MOMENTUM SOLAR 04 __ ___ ___ ______ 0 FIRE SETBACK 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 (36 ,18" VENTILATION, CUSTOMER INFORMATION 1'-6" ❑ ❑ 36" ROOF ACCESS) (TYP) SYMBOL LEGEND MARGARET RATERING-MS50117 9 -6" ❑ r4 -1 ❑ ❑ 6 u I MSP MAIN SERVICE PANEL CHIMNEY 7924 MERCHANTVILLE CIR ZEPHYRHILLS,FL 33540 q SP SUB-PANEL z SKYLIGHT (813)426-2046 �7 ❑ ❑ ❑ ❑ J PV SYSTEM INFORMATION //_�£_ ___ OM UTILITY METER ® VENT SYSTEM SIZE(DC):8.5 KW GUTTER 25 MODULES:HANWHA Q.PEAK DUO AC AC DISCONNECT 0 PIPE VENT BLK-G6+340 DISC 25 INVERTERS: EN PHASE IQ7-60-2-US 5' 10" UDC UTILITY DISCONNECT FAN LC LOAD CENTER SATELLITE DISH PROJECT INFORMATION GROUND ACCESS (TYP) INITIAL DATE: 5/27/2020 DESIGNER:SN N3R NEMA 3R BOX W/ENVOY-S FIRE SETBACKS AS PER 6TH EDITION 2017 FFPC REV: DATE: DESIGNER: MIN 3'x3'GROUND ACCESS REV: DATE: DESIGNER: CB COMBINER BOX POINT NOTE: ROOF LAYOUT C ❑I MODULE PITCH DIRECTION 1. ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE. __JJ 2. REFER TO LAYOUT DETAIL DRAWING PV-3 FOR ALL ROOFTOP DIMENSIONS. _ WIND PRESSURE ZONE LINES.REFER To PV-2.2 FOR ADDITIONAL INFO PV MODULE RATINGS INVERTER RATINGS VOLTAGE DROP CALCULATIONS MODULE MAKE HANWHA INVERTER MAKE ENPHASE FORMULA USED PER NEC 2014 HANDBOOK 215.2(A)(4) WHERE APPLICABLE MODEL Q.PEAK DUO MODEL IQ7-6O-2-US WIRE RUN VmP Imp R L (FT) VD % VD WIRE SIZE momentum BLK-G6+340 MAX OUTPUT POWER 240W BRANCH TO 3-BOX 240.00 13 1.98 85.58 4.406 1.84% 12 AWG MAX POWER 340W OPEN DC VOLTAGE 48V PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR OPEN CIRCUIT VOLTAGE 40.66V J-BOX TO LOAD 240.00 25 1.24 50.00 3.100 1.29% 10 AWG 325 HIGH STREET,METUCHEN,NJ 08840 NOMINAL AC VOLTAGE 240V CENTER (732)902-62-524 24 MPP VOLTAGE 33.94V MOMENTUMSOLAR.COM LOAD CENTER TO AC 240.00 31.25 0.778 3.00 0.146 0.06% O8 AWG PROFESSIONAL SHORT CIRCUIT CURRENT 10.52A MAX AC CURRENT 1A DISCONNECT CEC INVERTER EFFICIENCY 97% AC DISCONNECT TO ENGINEERING MPP CURRENT 10.02A 240.00 31.25 0.778 10.00 0.486 0.20% 08 AWG NUMBER OF MODULES 25 NUMBER OF INVERTERS 25 INTERCONNECTION UL1703 COMPLIANT YES UL1703 COMPLIANT YES PV BREAKER I NEC 705.12(D)(2)(3)(b) 120%RULE SUB PANEL # OF MODULES PER BRANCH I THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2017 (1.25 x INVERTER OUTPUT)+MAIN OCPD≤BUS RATING x 1.20 BREAKER SIZE I I FLORIDA BUILDING CODE AND THE 2014 NATIONAL ELECTRICAL CODE UP TO 16 20A I (1.25 x 25)+200≤200 x 1.20 \ %•t 11111, 25 HANWHA Q.PEAK DUO BLK-G6+340 340W MODULES PAIRED WITH I 25 ENPHASE IQ7-60-2-US MICRO-INVERTERS •: BRANCH CIRCUIT A 13 MICRO-INVERTERS EXISTING EATON 200A MAIN O STATE of •' �Lu� BRANCH CIRCUIT B SERVICE PANEL 240 V � �� ••.FLaRf,A.•• (.���� 12 MICRO-INVERTERS "' MAIN BREAKER: 200A �°����IONAU ee�` pp pp ENPHASE 80A U - + AC COMBINER SOLAR CIRCUIT BOX DISCONNECTING MEANS _ _ = II 200A f f f EATON 60A FUSIBLE AC GRID DISCONNECT 0 0 SOLAR CONTRACTOR 8 CAMERON CHRISTENSEN 40A 35A CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 MOMENTUM SOLAR fl fl ? 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 ROOF 10A BREAKER POWER UTILITY CUSTOMER INFORMATION JUNCTION (ENVOY) 40A FUSES GROUND METER 1 BOX 2A B 20A BREAKER (A)3 3 MARGARET 7924 MERCHANTVILLE CIR117 TERMINATION CAP 20A BREAKER(B) INSTALLED ON ZEPHYRHILLS, FL 33540 END OF CABLE (813)426-2046 PV SYSTEM INFORMATION SYSTEM SIZE(DC):8.5 KW 25 MODULES: HANWHA Q.PEAK DUO BLK-G6+340 Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire 25 INVERTERS: ENPHASE IQ7-60-2-US Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC (A) Correction Current(A) Size Type 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 1 1.25 16.25 12 AWG Trunk Cable PROJECT INFORMATION INITIAL DATE: 5/27/2020 DESIGNER:SN 2A 1" PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 13 1 1.25 16.25 08 AWG THWN-2 REV: DATE: DESIGNER: 2B 1" PVC 2 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 12 1 1.25 15.00 08 AWG THWN-2 REV: DATE: DESIGNER: 3 1" PVC 3 +G 08 AWG THWN-2 75°C 50 0.96 1 48.00 25 1 1.25 31.25 08 AWG THWN-2 THREE LINE DIAGRAM NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. PV-3 ALL WARNING SIGN(S)OR LABEL(S)SHALL COMPLY WITH 2014 NEC ARTICLE 110.21(B).LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD.LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT,AND LABELS REQUIRED SHALL BE SUITABLE FOR THE ENVIRONMENT. TAG LABEL QUANTITY LOCATION NOTE EXAMPLES kk momentum SOLAR MAIN SERVICE PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 0 1 POINT OF INTERCONNECTION O 325 HIGH STREET,METUCHEN,NJ 08840 PANEL (732)902-6224 MOMENTUMSOLAR.COM PROFESSIONAL ENGINEERING © • • • 1 COMBINER BOX 1 AT ANY JUNCTION BOX OR DC • • • •• • • • • COMBINER IF USED • I\iiilij/f • ''• 1 AT ANY JUNCTION BOX OR DC O 1 JUNCTION BOX •• • • COMBINER IF USED � © •�_ - 0 -yfr STATE OF • • . • • .,��a®ONA6 e�� •- �� A •- • • • - • :• • 1 OF EACH AT FUSED AC O ••• • • DISCONNECT ••• •• • 1 AC DISCONNECT COMPLETE VOLTAGE AND PHOTOVOLTAICCURRENT VALUES ON • • � - DISCONNECT LABEL - • • • irrrrur SOLAR CONTRACTOR • • CAMERON CHRISTENSEN ICERTIFIED SOLAR CONTRACTOR LICENSE NUMBER:CVC57036 • - •, • , • ' •• 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 CUSTOMER INFORMATION AMARGARET RATERING-MS50117 7924 MERCHANTVILLE CIR • ,• • • 1 MAIN DISCONNECT 1 OF EACH AT BUILDING MAIN ZEPHYRHILLS, FL 33540 O • •- - • • • • - - • • • PANEL DISCONNECT PANEL (813)426-2046 • •- o PV SYSTEM INFORMATION SYSTEM SIZE(DC):8.5 KW 25 MODULES: HANWHA Q.PEAK DUO A A • - • O • BLK-G6+340 •� " ' 3" 25 INVERTERS: ENPHASE IQ7-60-2-US QF - • •• 1 UTILITY METER 1 AT UTILITY METER I PROJECT INFORMATION INITIAL DATE: 5/27/2020 DESIGNER:SN REV: DATE: DESIGNER: � a',"...W"....,..., REV: DATE: DESIGNER: 1 AT EVERY SEPARATION BY OE • -• - •• MULTIPLE AC CONDUITS ENCLOSURES/WALLS! EQUIPMENT LABELS PARTITIONS/CEILINGS/FLOORS OR NO MORE THAN 10' PV-3 . 2 ELECTRICAL NOTES: 22. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 1. ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN CALCULATED USING THE MANUFACTURED STRING CALCULATOR 23. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER momentum BASED ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE NEC ARTICLE 300.6 (C)(1)AND ARTICLE 310.8(D). COEFFICIENTS. 24. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO(NEC 690.46-250.120 LOCATIONS PER NEC ARTICLE 310.8(C). 325 HIGH STREET,METUCHEN,NJ 08840 PARAGRAPH C).THE GROUND IS CARRIED AWAY FROM THE (732)902-6224 MOMENTUMSOLAR.COM GROUNDING LUG USING#6 BARE COPPER WIRE OR#8 THWN-2 COPPER 25. TOTAL AREA OF ALL CONDUCTORS,SPLICES,AND TAPS INSTALLED AT ANY CROSS WIRE. SECTION OF THE WIRING DOES NOT EXCEED 75%OF THE CROSS SECTIONAL AREA OF PROFESSIONAL THE SPACE. NEC 312.8(2). ENGINEERING 3. THIS SYSTEM COMPLIES WITH NEC 2014 26. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE CONDUIT,COMBINER,JUNCTION BOX, DISCONNECT.AND COMPLIES WITH 690.6-NO DC LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. SHALL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. IN ADDITION,VOLTAGE DROP CALCULATIONS FROM PANELS TO THE 27. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER COMBINER BOX SHALL BE SHOWN IN A SIMILAR FASHION 690.56(C).AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52. 5. ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 28. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS.690.6. � t i i i t I!/ I/ 6. ALL EQUIPMENT INSTALLED IS RATED AT 75°C -�' >�• // 29. ALL GROUNDING SHALL COMPLY WITH 690.47(A)IN THAT THE AC MODULES WILL COMPLY . f• oOEFlSF/. $ i� 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM WITH 250.64. EQUIPMENT DATASHEET ; : o86753 30. NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE - - 8. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SYSTEM 690.17,690.6. LOCAL AND NATIONAL CODE REQUIREMENTS. •�,I 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705.12(D)(3), 'P STATE OF / 9. EACH MODULE MUST BE GROUNDED ACCORDING TO USER 705.12(D)(2)(3)(B),705.12(A)AS PERMITTED BY 230.86(6) - �` OR p ?� INSTRUCTIONS �i l� t9 1� 10. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D) LABEL WARNINGS SHALL ADEQUATELY WARN OF THE LABE LS BES SHALL BE 32. I WITH LI 1(B) PERMANENTLY AFFIXED TO THE EQUIPMENT,AND LABELS REQUIRED SHALL BE 11. PER NEC 690.17, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE SUITABLE FOR THE ENVIRONMENT. TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION>SIGN SHALL READ*WARNING-ELECTRIC SHOCK 33. PV POWER CIRCUIT LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM HAZARD-DO NOT TOUCH TERMINALS-OR EQUIVALENT. THAT IS SEPARATED BY ENCLOSURES,WALLS, PARTITIONS, CEILINGS,OR FLOORS. TABLE 1: 12. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY iVOLTAGE CONDUCTOR CONDUCTOR SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT MAKE I MODEL IRATING RANGE MAIN RANGE TAP SOLAR CONTRACTOR SERVICE ENTRANCE. -I I I CAMERON CHRISTENSEN ILSCO IPC 4006 600 V 4/0-4 AWG 6-14 AWG CERTIFIED SOLAR CON LICENSE NUMBER:CVC57036 MOMENTUM SOLAR 13. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 690.64 I I I I I 5728 MAJOR BLVD. SUITE 307,ORLANDO FL.32819 ILSCO IPC 4020 I 600 V 4/0-2 AWG 2/0-6 AWG CUSTOMER INFORMATION 14. AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB-CIRCUIT BRANCHES IS ACCEPTABLE. INSTRUCTIONS FOR LINE TAPS MARGARET RATERING-MS50117 7924 MERCHANTVILLE CIR 15. ALL CONDUCTORS MUST BE COPPER. ZEPHYRHILLS,FL 33540 FIGURE 1: (813)426-2046 16. NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER 1. ADJUST THE CONNECTOR NUT TO PV SYSTEM INFORMATION NEC 250.24(C). SUITABLE LOCATION 2. PUT THE BRANCH WIRE INTO THE CAP SYSTEM SIZE(DC):8.5 KW 17. EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A SHEATH FULLY 25 MODULES:HANWHA Q.PEAK DUO 3. INSERT THE MAIN WIRE, IF THERE ARE BLK-G6+340 GROUNDING ELECTRODE SYSTEM PER 250.54(D). TWO LAYS OF INSULATED LAY IN THE 25 INVERTERS:ENPHASE IQ7-60-2-US 18. FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA MAIN CABLE,SHOULD STRIP A CERTAIN DC. LENGTH OF THE FIRST INSULATED LAY FROM INSERTED END PROJECT INFORMATION 19. SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION 4. TURN THE NUT BY HAND,AND FIX THE INITIAL I DATE: 5/27/2020 DESIGNER:SN PIERCING CONNECTORS(IPC). MAKE, MODEL,AND RATING OF CONNECTOR IN SUITABLE LOCATION. REV: DATE: DESIGNER: INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 5. SCREW THE NUT WITH THE SLEEVE SPANNER. REV: DATE: DESIGNER: 20. METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1 6. SCREW THE NUT CONTINUALLY UNTIL THE TOP PART IS CRACKED AND ELECTRICAL CONT. 21. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC DROPPED DOWN SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. P V-3 . 1