Loading...
HomeMy WebLinkAbout20-249 m �I City of Zephyrhills _;PERMIT NUMBER : _ 5335 Eighth Street Zephyrhills, FL 33542 BNR-000249-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 07/16/2020 Permit Type: Building New (Residential) Property Number Street'Address.< 25 26 21 0110 00000 3010 3022 Lytton Hall Dr Owner lrifoimation Permit Information Contractor;lnfomation Name: LENNAR HOMES LLC Permit Type:Building New(Residential) Contractor: LENNAR HOMES LLC Class of Work:SFR Construct Address: 4600 W Cypress St 200 Building Valuation:$232,928.00 TAMPA,FL 33607 Electrical Valuation:$1.00 Phone: (813)574-5700 Mechanical Valuation:$1.00 �1 (, 6 Plumbing Valuation:$1.00 Total Valuation:$232,931.00 I Total Fees:$18,777.47 Amount Paid:$18,777.47 Date Paid:7/20/2020 8:31:36AM Project,Description CONSTRUCT SINGLE FAMILY 2,008 SQ FT Application Fees School Impact Fee $8',328.00 Public Safety Impact Fee-Admin $26.35 Transportation Impact Fee-City $36.32 Mechanical Permit Fee $123.38 Park Impact Fee-Single Family/Townhome $769.56 Transportation Impact Fee $3,595.68 Water Connection Residential Fee $1,010.00 SIF 1 percent Fee $83.28 Sewer Connection Residential Fee $2,090.00 3/4 Water Meter Fee(Calc) $473.78 Electrical Permit Fee $264.38 Building Permit Fee $1,273.49 Public Safety Impact Fee-Fire $273.00 Public Safety Impact Fee-Police $254.00 Plumbing Permit Fee $176.25 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. all CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE11111 FOR OF i BILLING CONTACT STEVE SMITH LENNAR HOMES LLC 4600 W CYPRESS ST TAMPA, FL 33607 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00000313 07/13/2020 07/13/2020 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-000249-2020 3/4 Water Meter Fee(Calc) $473.78 Building Permit Fee $1,273.49 Electrical Permit Fee $264.38 Mechanical Permit Fee $123.38 Park Impact Fee-Single Family/Townhome $769.56 Plumbing Permit Fee $176.25 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Fire $273.00 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 Sewer Connection Residential Fee $2,090.00 SIF 1 percent Fee $83.28 Transportation Impact Fee $3,595.68 Transportation Impact Fee-City $36.32 Water Connection Residential Fee $1,010.00 3022 Lytton Hall Dr Zephyrhills, FL 33542 SUB TOTAL $18,777.47 REMITTANCE INFORMATION TOTAL $18,777.47 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 July 14,2020 �: � � 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 PASCO COUNTY, FLORIDA Permit No. �, [/ Date Permitted 1...Builder Name/Owner Name A�r 1b7n Control#• I ' County Parcel No, SubDiv: 4,Men &)A,— Address/Location 302..2_ �.tP�� 1 'e _ f ` Classificatlon/Type of t.lsi � TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑Ves ❑ No How Determined impact Fee Amount $;c 6 32,. 6D Zone No. TAZ: ° SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [�Yes ..❑No How Determined PARKS AND-RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 7& i csry Exempt ❑Yes No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total ���,,���� Exempt ❑Yes ❑ No How Determined Total Amount<5!--- RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TO'PAL AMO14NTS'LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICMOF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the buliding permit owner.on notice of this assessment and the condrdons of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received JUN Phone Contact for Permitting 813 363 _ 2891 —1-1— 1_ —— — — ri—l-1 T — — Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 3022 Lytton Hall Drive LOT# 0301 SUBDIVISION Hidden River Phase 2 PARCEL to# 25-26-21-0110-00000-3010 ,,,��,, (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II�/ II NEW CONSTR B ADD/ALT 0 SIGN 0 DEMOLISH INSTALL REPAIR PROPOSED USE SFR 0 COMM OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME 0 STEEL Q DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 2008 SQ FOOTAGE 1555 HEIGHT 1 Story ��✓ BUILDING $ VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ ®AMP SERVICE PROGRESSENERGY Q W.R.E.C. PLUMBING $ ,,,,,, ••••�I�/ ...(•••MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION 2- r =GAS W] ROOFING SPECIALTY � OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA CI u YES I o BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N i Address 4600 W.Cypr s t.Ste.200, pa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE F Y REGISTERED Y/ N FEE CURREN Y/N of I Address 1034 Skipper Mad, Tamp 33613 License# I EC13005408 PLUMBER 40 00MPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308/gayorpt, FL 34674-5308 License# I CFC042998 MECHANICAL , COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE ev REGISTERED I Y/ N FEE CURREN I Y/N Address P.O. Box 530 ayonet 34674-5308 License# CAC058062 OTHER COMPANY C Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address 4211 Shoal L' 'Blvd, Spring Hill, FL 34607 License# 1 CCC057991 111111111111111 11 �. 11111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. 4���1�1 . . . Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions' which may be more restrictive than County regulations. The undersigned assumes respohsibility for;compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may.be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO PETAIN FINANCING, CONSULT WITH YOUR LENDER OFi AN ATTORNEY BEFORE RECORDING YOUR NOTICE& COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) A OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirnivkwre me this Subscribed and sworn to(or aff rm ) ore me this L4-F1�f-LU by Ashlee Callahan 24-Apr-20 by Ashlee Cal h n Who is/are personally known to me or Uag' Who is/are personallyknown to me or as ification. as identification. Notary Public Notary Public fission No. FF985637 Commission No. FF985637 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped .'� ;G�trriiei'aniMpp�G�B7T . �.�trm"ai'anidPPDW9}T ' f'riluci 0rxb#Q �.,id�a ,�r�,twati,s+s0aaa5�vlo „ l4vileliluf�RaS,lpot��Kid{�11r1411 PLOT PLAN SKETCH ONLY SEC. 24,25 , TWP. 26 S, RNG, 21 E. NOT A BOUNDARY SURVEY LOT 301 BEARING BASIS: HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00*23*02" E PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS N NOTES TAKE PREFERENCE. THIS PLAN IS FOR PERMITTING PURPOSES LOT = M_Q_0_-00 SQ. FT. ONLY, NOT FOR CONSTRUCTION, VERIFY LIVING AREA =_1_5_2L__SQ. FT. ALL DATA SHOWN HEREON BASED ON THE ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY = 45 —SQ. FT, ENGINEERING PLANS OF KIMLEY-HORN AND GARAGE = 406---SQ. FT, ASSOCIATES, INC., PROVIDED BY LENNAR HOMES. LEGEND: COVERED LANAI =_ N/A--SQ. FT. II 10' PUBLIC UTILITY EASEMENT ­vw— = PROPOSED DRAINAGE FLOW PATIO =_.2_3___SQ. FT. (00.00) = PROPOSED GRADE CONIC. DRIVE = 456 -SO. FT. E-00.00 = EXISTING GRADE A/C & CONC PAD =__R___SQ. FT. PRIVATE SIDEWALK = 28---SQ. FT. Ln NOTES: IMPERVIOUS = 38 __% LOT GRADING TYPE = A = 2523 -SQ. FT. + PROPOSED PAD ELEVATION = N/A SOD = 40_7_7 __SQ. FT. FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS SIDE SETBACK = 10' RIGHT OF WAY =--12-0.9-0--SQ. FT. REAR SETBACK 10' DRIVE APRON =—L4-4 -SQ. FT. PUBLIC SIDEWALK = 240—SQ. FT. SOD = 336 —SQ. FT. TOTALS AREA = Z3-LC LO-Q-SQ. FT. DRIVEWAY = 600 --SQ. FT, LOT 297 SIDEWALK FT. SOD 4413 -SQ. FT. I Iq LOT 302 LOT 298 N,30o �5�o a�u',. 00' o A 0 % LOT 299 <01 <� L011 0 Ln Ln 9 0 0_1 . r tin 0 CD 69 (70.60) LOT 300 cc Irp 6 PC(P) PROPOSED: LOWEST FLOOR ELEVATIONS: 0 LIVING AREA: 71.75' DESCRIPTION: GARAGE AREA:ELEVATIONS REFERENCED TO LOT 301, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE '2", NATIONAL GEODETIC VERTICAL AS RECORDED IN PLAT BOOK 079, PAGES 102 THROUGH DATUM OF 1929. MEAN SEA 110, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. -APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101C 0458 F EFFECTIVE DATE: 09/26/2014 z uj Square Feet: 6600.00+ LEN'NAR HOMES IMEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE. A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, cu F/C- FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D- FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE- LOWEST FLOOR ELEVATION, MAS,= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT L REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK No.4493, TBM= TEMPORARY BENCHMARK, ULP= UTILITY POLE, W/F= WOOD FENCE > Drown By: JOHN R.BEACH&ASSOCIATES,INC. SMS SURVEYORS AND MAPPERS Checked t By:911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 Scale: WAY (813) 854-1276 FAX (813) 055-8370 1'=30' O NOT VALID WITHOUT ORIGINAL Date: PLOT PLAN 6/2/2020 ACS '(r'? z m AND SEAL OF A FLORIDA LICENSED VSAAT SURVEYOR AND �p N ' - . )DATE MAPPER L40HN R. Bb;CH Revisions: FLORIDA REG. UND SURVEYOR No. 2984 LB 4493 JEFF M. HARTO 4dPRQFE95KWAr-SURVF_YOR & MAPPER No.7123 99, /AV A -7 uz 00C 9!9 lb 69 SY WWI 66 -zr- NO NNE E8q p LZ L!Ei-i eO Ev 9.9 t Is `-,`� F \\`',\ j ����6�t' '1 •ti,Q,1`�'`3 1`1 .i''�,,,.f�r r �,� \.`\�„r''!,.-y'r'J i y ��'�� �� �' Lt� VI, kip V, Coe4s Se e 73 j 9-6e 9OZI r.A '09 ja Aft-- 09-c-, v oce 77� ozzi Al (J&�"�' " -I- Goe ti !Zezz -——————— ——1 1) 1. -————— t 3 -cz It p9e dd 141istbee as v IVHd 90t, v 'P6e -4 tG , D s Single Family Dwelling Plan Review Comments 1. F.F.E.shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots sliall.be graded to.comply with R401.3 of the V.B.C. 3: Compaction test required if 24"or more of fill dirt is brought in at any one place. 4: Tie in survey required.before.pounng concrete. 5. Driveways require.a R.O.W.use permit: All 4 sides-of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7: .All property markers shall be uncovered.and marked at time.of first inspection. K All A:D.A."requirements shall,be met: 9: No electric,plumbing; mechanical,or framing shall.be:covered without an inspection.and . . approval first: 10: All Garages,shall comply with section R302:6 of the F.B:C.{Fire Separation): J.L Appliances shall not be installed in a location where subject:to mechanical.damage unless protected by.approved barriers. M303:4 of the F.B:C 12. Water heaters shall comply with section P607.3.of the F)IC: 13:Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1. 14. Return air in all bedrooms. F.B:C. M1620-4 1.5. Smoke detectors.are to be installed in accordance with R313:1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308A of the F.B.C: 17..All means.of egress are to be in accordance with R3 H of the F.B.C.. 18. "Green:gypsum board" shall not be used as a backer in showers or tubs. R702:4:2 P.B.C. . 10. Combination-type AM breakers are required;at all locations requiring an AFCI type breaker. 20. Carbon monokide alarms will be required in new construction that uses fossil-burning heating or appliances or an.attached garage. They shall be installed in accordance-with the F.B.C. 2:1. All plumbing,mechanical, and electrical shall be separate from unit,to unit: This includes_ all underground plumbing and electric. 2I All 2U6 N.E.C. Codes will be enforced: 23:Tamper- Resistant Receptacle, in accordance with 406.11 ofthe 2016 N:E:C . 24. In accordance with the Land Development Code, lots.shall.be sodded before final at least 10 feet around the structure. 25. R403.5.3Hot water pipe insulation. Insulation for hot.water-'pipe with a minimum thermal resistance I.(R value)-of R-3 shall.be applied to the - following-:- Piping-/: inch (19:1.mm) and larger in.nominal diameter. Piping:serving more than:one dwelling unit. Piping located outside'the conditioned space:.. Piping from the water heater to a:distribution manifold:. Piping.located under a floor slab. Buried in piping.: Supply and return piping in recirculation'systems other than demand recirculation-systems. 25:Blower door test shall be proviided-before C.O: 26.A copy of the energy cacls shall be with permit at all times 27.'Copy of&al.:insulddon reportshalhbe provided ivith permit before flnah 28:No fence.-pool or screen enclosure is issued withahis permit F:F.E..Finished Floor Elevation F.B.C- Florida Building Code 6a'Edition R.O.W-Right of Way A.D.A.=.Americans with Disabilities Act. N.E.C.-National Electric Code(2016) PASCO-ICOUNtY Receipt 0.411,1/20116 EiUlLDl14G!873; CONSTRUCTION SERVICES Rd Ot NU,hh�er: MOW PAS.CCitizens Drive COUNTYte.= FLORIDA:. .FLOIRUIDA OkLk SMcm.Vmkwr VLAcEs. r4OW Port Richey-FL 34654 727-847--8126 NOT A PERMIT '** Paid By dheek,# 66 Auih-# Cashier ID Workstatildn. Check* 01604217 MLARNOLO 8000P50W. Feb D6s6rlption AmountP611d Impact Fde Ribsiddriti6l Solid Waste Single Farhily 15;12- Total Payments: $1512 Pavor Addiis Phone LE.NMIR Comments: 3 -LY. TON'HALL;DR' Q22: YT PERMIT 249 25-26-21-01 ID-OOOOQ-3010 WhIleyomwilf Paying Yqu!kj.wIth Pasco county buIiding'6o;!syuctio,nsery- Ices,"the fuit aih66fit i�f i4dit iid or e-chi6k feis,NOrsh6wh alioVd,Is c6lfect(A by First - . n7yreportSIrepoitSlIPASCOPRODIPA-S.Colcust6met Receipt Of rpt Print Date: 10/13/2020 Pag&1 of 1