Loading...
HomeMy WebLinkAbout20-252 r r F to City, of Zephyrhilis PERMIT,,NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BNR-000262-2020 Phone: (813) 780-0020 Fax: (813)780-0021 Issue Date: 08/11/2020 4 Permit Type: Building New (Residential) Property Number Street Address 24 26 210110 00000 3020 3034 Lytton Hall Dr Owner,Information Permit Information Contractor Information Name: LENNAR HOMES LLC Permit Type:Building New(Residential) Contractor: LENNAR HOMES LLC Class of Work:SFR Construct Address: 4600 W Cypress St 200 Building Valuation:$267,656.40 TAMPA,FL 33607 Electrical Valuation:$1.00 Phone: (813)574-5700 Mechanical Valuation:$1.00 Plumbing Valuation:$1.00 Total Valuation:$267,659.40 Total Fees:$16,084.97 Amount Paid:$19,084.97 Date Paid:8/11/2020 8:48:33AM ttt Project,Description = CONSTRUCT SINGLE FAMILY 2,376 SQ FT Application Fees Park Impact Fee-Single Family/rownhome $769.56 Mechanical Permit Fee $144.90 Electrical Permit Fee $310.50 Transportation Impact Fee-City $36.32 Transportation Impact Fee $3,595.68 Sewer Connection Residential Fee $2,090.00 Public Safety Impact Fee-Fire $273.00 Public Safety Impact Fee-Admin $26.35 Building Permit Fee $1,482.60 SIF 1 percent Fee $83.28 Water Connection Residential Fee $1,010.00 Public Safety Impact Fee-Police $254.00 Plumbing Permit Fee $207.00 School Impact Fee $8,328.00 3/4 Water Meter Fee(Cale) ,$473.78 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. '"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property.if you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. /4d OA-e-, CONTRACTOR SIGNATURE PE 71IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM {HEATHER Lennar Homes-3034 Lytton Hall Dr:2,376 sgft Column 'SQ. FEET PRICE MAIN OR LIVING: 2,376 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 267,656.40 FEE SHEET $ 1,380.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,482.60 ELECTRICAL: $ 310.50 PLUMBING: $ 207.00 MECHANICAL: $ 144.90 SUB-TOTAL $ 2,145.00 TOTAL $ 2,145.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,272.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 8,328.00 100.0% $ 8,328.00 1.0% $ 83.28 TOTAL: $ 8,411.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 19,084.97 PASCO COUNTY, FLORIDA Permit No. � 2,52— Date Permitted ai;0_ Builder Name/Owner Name n pl,f�ia t' /Tzrrt�s Control# County Parcel No. ZC�,, .y(� b t '0=160Z SubDIV: �Pn Address/Location 3DNbwL Class`ificationrrype of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 4 37 Exempt ❑ Yes ❑ No How Determined Impact Fee Amount $. Zone No. TAZ: SCHOOL IMPACT FEE / Account (056) Single-Family Detached House Amount $ �([ (057) Mobile.Home (058) Other Residential 23) Collection Fee Exempt d Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Exempt ❑Yes [] No How Determined f s LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amount RESOURCE FEE ERU- TOTAL AMOUNT Prepared By i� T Checked By NO CERTIFICATE OF OCCUPANCY WILL BE-ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN RAID AND RECEIPTED.FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received JUN 0 9 2020 Phone Contact for Permitting =813 .363 2891 —rrr>rrrrr —rr Owner's Name Lennar Homes,LLC Owner Phone Number 813.574,5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 3034 Lytton Hall Drive LOT# 0302 SUBDIVISION Hidden River Phase 2 PARCEL ID# 24-26-21-0110-00000-3020 ,�h (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II.� II NEW CONSTR H ADD/ALT 0 SIGN Q Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR 0 COMM 0 OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME 0 STEEL DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R IF 2376 SQ FOOTAGE 1936 HEIGHT 1 Story IT BUILDING $ C r VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ f lf' ® PROGRESS ENERGY Q W.R.E.C. AMP SERVICE PLUMBING $ r� ;h III/ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS � ROOFING Q SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA El YES �JO uu BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypr St.Ste. 0 ampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY I Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skipper oad, Ta a, FL 33613 License# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 53 Bay9r FL 34674-5308 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 53 , Ba on , FL 34674-5308 License# I CAC058062 OTHER COMPANY C Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4211 Shoal ine Blvd, Spring Hill, FL 34607 License# 1 CCC057991 11111111111111 11111111111111111�11111111111111111111111111111111111 RESIDENTIAL Attach(2) lot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum n(10)working days after submittal date.'Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects . COMMERCIAL Attach(2)complete sets of Building Plans,.plus a Life Safety Page;(1)set of Energy Forms.R-OA1V Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. "&.11..1..4.1..��1..4�1..1..4.:.:..: '.'�1. 1�1..1..4.1..�1.. { {:.i����1..��1..����1..��C..i..ri.:r�:..r'�' ��1..��4��..1�{�� Directions: Fill out application completely. : , Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions' which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is . hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered,abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEN TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER ORLA ATTORNEY BEFORE RECORDING YOUR NOTI E OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03 OWNER OR AGENT CONTRACTOR ell Subscribed and sworn to(or affi I le me this Subscribed and sworn to r before me this L4-Hpl-LU by Ashlee Callahan 24-Ap,20 by Ashlee r ahan Who is/are personally known to me or his/have prGd GGd Who is/are personally known to me or identification. s identification. Notary Public Notary Public Commission No. FF985637 Commiss n No. FF985637 Elissa M.Holleran Elissa M.Holleran Name of Notary tvved,printed or stamped Name of Notary typed,printed or stamped " KIRM11,01MIEMN 4 r�rtn,���a�drFn�ear Elt. 6; r,�rtrtf�'aeiMPPeW®lf °•f�'Vt�But�d,T6�0 r FYt�111rEu0,xl G R tit,1d*n!j rcl7tvitsIN14C-31�; f�i�n��r•.�t�.�tua;,t�tasat5•»:U � 9�u D Q • Single Family Dwelling Plan Review Comments 1. F.T.E.- shall:be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R-401.3 of the F.B.C. 3: Compaction test required if 24" or more of fill dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All.property markers shall be uncovered and marked at time of first inspection. 8: All A:D.A.reguiremchts shall be met. 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and approval first: 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed.in a location where subject.to mechanic_ al damage unless protected byapproved barriers. M303A of the F.B.0 12. Water heaters shall comply with section P607.3 ofthe.F.B.C. 13.-Foundation supports forAX uniis.shall be raised at least 3" above finished grade. M1308;1 14. Return air in all bedrooms. F.B.C. M1620.4 1.5. Smoke detectors are to be installed_ in accordance with R313.1 of the F.B.C. 16.All glazing requirements are to be in accordance with R308.4 of the F.B.C: 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green:gypsum board"shall not be used as a backer in showers or tubs. R702.4.2 F.B:C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached-garage. They shall be installed in accordance with the F.B.C: 21. All plumbing, mechanical,- and electrical-shall'be separate from unit to unit. This includes all ..underground plumbing and electric. 22. All 201.6 N.E.C. Codes will be enforced. 9 23. Tamper-Resistant Receptacles in accordance with 406.11 of the.2016 N.E.0 .24. In accordance with the Land Development Code,lots shall.be sodded before final at least 10 feet around the structure. .25-. R403.5.3Hot Water.pipe insulation Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall.be applied to the following: Piping inch (19.1 mm) and larger in, nominal diameter, Piping serving more than one dwelling unit. Piping located outside the conditioned space.,. Piping from the water heater to.a distribution manifold: Piping located under a floor'slab.' Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25:Blower door test shall be provided before C.O. .26.A copy ofthe enemy cacls shall be with permit at all times 27. Copt/of final insulation report-shall be provided with permit before fnaL 28 No fence,-pool or screen'enclosure is issued with:this permit F.F.E.-Finished Floor Elevation RB.0 Florida Building Code 6U'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric.Code(2016) PLOT PLAN NOT ASBOUNDARYKETCH ONLY SURVEY SEC. 24,25 , TWP. 26 S, RNG. 21 E. LOT 302 BEARING BASIS: HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00-23'02- E PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS N NOTES TAKE PREFERENCE. THIS PLAN IS FOR PERMITTING PURPOSES LOT = §_l!0_0.(:L0_SQ. FT. ALL DATA SHOWN HEREON BASED ON THE ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA 1935 --SQ. FT. ENGINEERING PLANS OF KIMLEY—HORN AND ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY 24 --SQ. FT. ASSOCIATES, INC., PROVIDED BY LENNAR HOMES. GARAGE 416 --SQ. FT. Il LEGEND: COVERED LANAI ==N k:—SQ. FT. 10' PUBLIC UTILITY EASEMENT van s- = PROPOSED DRAINAGE FLOW PATIO FT. 00.00) = PROPOSED GRADE CONC. DRIVE =__AZ5_SQ. FT. E-00.00 = EXISTING GRADE A/C & CONC PAD =_A___SQ. FT. PRIVATE SIDEWALK FT. NOTES: IMPERVIOUS LOT GRADING TYPE = A = 2912 —SQ. FT. PROPOSED PAD ELEVATION = N/A SOD =__368_8 _SQ. FT. FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS SIDE SETBACK = 10' RIGHT OF WAY =__ZZ0 LD0 SQ. FT. REAR SETBACK 10' DRIVE APRON = 14_4 _SQ. FT. PUBLIC SIDEWALK =___140_SQ. FT, SOD 336 --SQ. FT, TOTALS AREA =___73_20_-0.0_SQ. FT. DRIVEWAY = 9 61L—SQ. FT. SIDEWALK =_16-1—SQ. FT. SOD 4024 —SQ. FT. LOT 296 LOT 303 LOT 297 '0 N C3 X 0 0 , W:00. 0 CD LOT 298 0 -(71 .09) Ln Ln 0 o, CD -p co LOT 301 Q 0 O PROPOSED: LOWEST FLOOR ELEVATIONS: o LIVING AREA: 71.55' P2. DESCRIPTION: GARAGE AREA: ELEVATIONS REFERENCED TO LOT 302, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", NATIONAL GEODETIC VERTICAL AS RECORDED IN PLAT BOOK 079, PAGES 102 THROUGH DATUM OF 1929. MEAN SEA r a- 110, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101C 0458 F EFFECTIVE DATE: 09/26/2014 Square Feet: 6600.00 t LENNAR HOMES EGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= 'PLAT DATA, ;.= CENTERLINE,''A/C= AIR.CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED,-E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND OUND NAIL & DISK, FPP= FOUND PINCHED mkA PIPE, LFE= LOWEST FLOOR ELEVATION, MAS,= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLA7,BOOK,Pcp­_.pmMANENT-CONTROL POINT, PRM= PERMANENT mc REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2- IRON ROD & CAP No. 4493, SN&D= SET NAIL &-.DISK No.4493, TBM= TEMPORARY L <BENCHMARK, U/P= UTILITY POLE, W/F= WOOD FENCE - awn 13y: JOHN R.BEACH&ASSOCIATES,INC. Dr SMS SURVEYORS AND MAPPERS Checked By: t 911 WEST ST. PETERSBURG DRIVE -a JRB 'a ONE OLDSMAR. FLORIDA 34677 scale: + WAY (813) 854-1276 FAX (813) 855-8370 1"=30' 1 NOT VALID WITHOUT ORIGINAL SIGNATURE Date: PLOT PLAN 6/2/2020 ACS :Ui AND SEAL OF A FLORIDA LICENSED Sl DATE 5 SURVEYOR AND MAPPER I OHN R. H .0 Revisions: PFLORIDA R'EG, ND,SURVEYOR No. 2984 LB#4493 M J t JEFF M. HARTLU _aajDFZSS*NAt—SURVEYOR & MAPPER No.7123 INSTrw 2020130979 OR BK 101 55 PO 1686 Pogo 1 of 1 08f1112020 OZ28 PM Rapt:2192046 Rea 10.00 DS:0.00 IT:0.00 f NIIOd NwrezSowles,Eeq„Pasco County Clerk 31 Comptroller Perrrdt No. Parml ID No 24-26.21.0110-0000D-3020 NOTICE OF COMMENCEMENT Btsted Florida County of PaSCO THE UNDERSGNED hereby g"nob-that Imp.—.t wq be made to¢u.ln reel property,end in.—,dance wIN Chaphr713,Hold.StaDdea, the fdmft Inknnapon Is PwidM In Ws Nodm NCammaMsrnarrC 1. oesolplion of Property:Legal IJ•IOpEN RIVER PHASE 2 P07g NG91 •110 LOT372 st,mtAddm- 3034 Lytton Hall Drive zephryhfga FL 33541 2, Genomf Dmcripdm of Impavemrnt Single Family RoWenpe/Pool I Semen Enclosure I Fence 3. Oaeer hfemtaeon: Loner Homes,LLC. Us— Address W GYpress St.Ste 200 _ Jpmpa FL"0'7 4 Slate InIc-A In Property: Name ofF.Smpre TIIIehWdor -N/A 0f inner than miner) - Addresa OIY Sun. Cmr..der. Lennar Homes,LLC Name 4600 W Cypress St.Ste 200 Tampa FL 33607 Add... CRY store Contradore Tohphma No.: 613.574.5700 a smetY N/A Name Addms. CRY Amount ofBond:S_ Telephone No.: s Lendv: N/A IF. Name Address GTy Lander.Tdephena No.: a r 7. Paean.wI10In the Stole or Hodda deslgnded by the m om vner upon wh notices or door ft.."my be ecrved es prvNded W �jS F Q � Sedlon 71St3(n(aj(n.Florida Lennar Humes-LLC' '7 Nome 4800 W Cypress St,Ste 200 Tea FLU * 4-' Addrasa Oty Stole TWaphonm Number ofDedgnand Parson: 813.574.5700 r e. m addrdon to tdmnelr•ma ornardedgnow,_NIA or re reeehe a copy of 0a Llerrora Natlee ae proNded In 6edl0n 713.13(T)(b),Florida Sobaoe. TNeph.oNumberofPemonofE"DnlgratedbyO—. - Y W WIL Espbatlon d3b°f Noll®ofCammeeosmerdfs mreyeartmm Ore date ofineprdhg unless,adiflonndd3lehapedfed: ¢ U J J WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE E)G IRATION OF THE NOTICE OF COMMENCEMENT W LL U ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART1 6E 14713.13 FLOMDA STATUTES,AND CAN Ur 5...O Z H RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROP�RFY. A NOTIC�C OF COMMENCEMENT MUST BE O W a RECORDED AND POSTED ON THE 3013 SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT O U U)J 04 tl WTTH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECOFU31NG YOUR NOTICE OF COMMENCEMENT. uj STATEOFF70RIOA FL W W fn O Q COUNTY OF PMELLAS d oa 81W. ra or 0. or Owner.Authortrad OfioaiDhadorJPartrrer/Manaper O 0O X 0 a .S Vice President _ yy,W LL a U Slgnatorye 7Wef(Mw 1�=O U LL The farepainp IrlWnsnentwe9 aWmawledged before me oils 24 day pf ril y _ _ a W O '- 32 Steve Robert Smith - m Wire President _ - C¢O �' _ (type d.uDt e(FlaK.°ustee,a0amyin kc0 for V 2 U U Z W Lennar Homes.LLC (name ofp ono mom ingDmneiRvra9...oiled). H}"F—J Q Personany Kneen■pB Pmdu®d lderdMullon❑ NotarY Sign - _ �_D.W O 2 O Type oflderlbfiagan Produced Horn°0' ISS 011eren W a LL 2 Q N 0.,1 W O O o W Vedfi®eon punvmrd lc Seos.n 92.s25,FlcrMP StoWtm Under penned a at padruy,I dedom ant I have mad the kmgallg and oral Oro kW doled M I LL Ram truab am East of my anal.lCdge end De1kL / •� Q�ZO J� i ty� / t3.LS6A1LH01lFRAR -StgoL--(Natural Person Sg"Abov. _ U)Q J W _ Q ammklleegFFIt869 Q LLI wydehlbd6ra f.mm sMlentey42o2tmamlmwulm t— O 7r Z m CITY OF " " BUILDING ZEPHYRHILLSNOTICE DEPARTMENT OF ADDITION OR CORRECTION . • NOT REMOVE ADDRESS DATE PERMIT# �i L i-4lfA9111Dr ��� ��z' THIS JOB HAS NOT BEEN COMPLETED. The following additions or correc4 ns shall be made before the job will be accepted. VV It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth or other material,until the proper inspector has had ample time to approve 780-0020 FOR R SPECTION the installation. OFFICE HOURS 8:00 AM-4:30 PM MON.-FRI. INSPECTOR