HomeMy WebLinkAbout20-253 m .
o
fl City of Zephyrhills . PERMIT NUMBER
: . _.
�$ � .:a.
? 5335 Eighth Street
Zephyrhills, FL 33542 BNR-000263-2020
Phone: (813)780-0020
r` Fax: (813)780-0021 Issue Date: 07/1612020
Permit Type: Building New (Residential)
Property:Number StreetAddiress
24 26 21 0110 00000 3030 3046 Lytton Hall Dr
Owne�,lnformation' Permit lnformation Con0acto"ir on K r..
Name: LENNAR HOMES LLC Permit Type:Building New(Residential) Contractor: LENNAR HOMES LLC
Class of Work:SFR Construct
Address: 4600 W Cypress St 200 Building Valuation:$264,000.00
TAMPA,FL 33607 Electrical Valuation:$1.00
Phone: (813)574-5700 Mechanical Valuation:$1.00 ^ -�
Plumbing Valuation:$1.00
Total Valuation:$264,003.00
Total Fees:$19,002.47
Amount Paid:$19,002.47
Date Paid:7/20/2020 8:27:17AM
P'�o�ec be§cription
CONSTRUCT SINGLE FAMILY 2,276 SQ FT
A0pl1c4t16n Fees
Electrical Permit Fee $298.13 Park Impact Fee-Single Family/Townhome $769.56
School Impact Fee $8,328.00 Public Safety Impact Fee-Police $254.00
Sewer Connection Residential Fee $2,090.00 Mechanical Permit Fee $139.13
Public Safety Impact Fee-Fire $273.00 Transportation Impact Fee $3,595.68
Building Permit Fee $1,426.49 Public Safety Impact Fee-Admin $26.35
Plumbing Permit Fee $198.75 3/4 Water Meter Fee(Calc) $473.78
SIF 1 percent Fee $83.28 Transportation Impact Fee-City $36.32
Water Connection Residential Fee $1,010.00
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
INVOICE11111
FOR
BILLING CONTACT
STEVE SMITH
i
i
LENNAR HOMES LLC
4600 W CYPRESS ST
TAMPA, FL 33607 i
INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION
INV-00000314 07/13/2020 07/13/2020 Due NONE
REFERENCE NUMBER FEE NAME TOTAL
BNR-000253-2020 3/4 Water Meter Fee(Calc) $473.78
Building Permit Fee $1,426.49
Electrical Permit Fee $298.13
Mechanical Permit Fee $139.13
Park Impact Fee-Single Family/Townhome $769.56
Plumbing Permit Fee $198.75
Public Safety Impact Fee-Admin $26.35
Public Safety Impact Fee-Fire $273.00
Public Safety Impact Fee-Police $254.00
School Impact Fee $8,328.00
Sewer Connection Residential Fee $2,090.00
SIF 1 percent Fee $83.28
Transportation Impact Fee $3,595.68
Transportation Impact Fee-City $36.32
Water Connection Residential Fee $1,010.00
3046 Lytton Hall Dr Zephyrhills, FL 33542 SUB TOTAL $19,002.47
REMITTANCE INFORMATION TOTAL $19,002.47
City of Zephyrhills
5335 8th Street
Zephyrhills, FL 33542
July 14,2020 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1
— ---- i
1.
i •
r, IAA-QCO COUNTY, FLORIDA
Permit No. ••25:3
Date Permitted '1% 2w�
Builder Name/Owner Name G.AAa-, Control#
County Parcel No. SubDiv:
s
Address/Locatlon All'lV`-
I
Classiflcation/Type of Use
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit:
Exempt []Yes ❑ No How Determined
Impact Fee Amount $. ,Cn 3-z'10 Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ 76
(057) Mobile Home
(056) Other Residential
123) Collection Fee
Exempt Yes ❑No How Determined
PARKS AND RECREATION FEE-
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ 7.
Exempt ❑Yes ❑No How Determined '
i
1:
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes ❑ No How Determined Total Amount
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By r7 Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
l BEEN PAID AND
?' RECEIPTED FOR BY A CENTRAL PERMITTING OFF10E-012 PASCO COUNTY
s
Acknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this forth,placing -
} the building permit owner.on notice of this assessment and the conditions of payment for same.
t
DATE RECEIVED BY
RECEIPT NO. DATE BY
0"
K3
....... 14,
CA
An
I r
N CD
rp
J. CJ7
C-rl Vo
co •
0
CA
M dR
i
ads. '-
t
C4 C) I i I C.
A I
�Rr
N
CA)
I j
c)
(0
cil
co
'\A
bD
th
CO
co 0"
rr,
-Sl
Lw
1po
OD -4-
CA
AS
eaft
0),
Co
rn
0)
0)
CMD 0
OD
CA) f 1N)
C-0
p. ill
p
O-D
(�o
0,
Cot N' (A) rn
(0
CA)
j.
/ SKETCH ONLY SEC. 24 TWP. 26 S, RNG. 21 E.
PLOT PLAN NOT A BOUNDARY SURVEY
LOT 303 BEARING BASIS:
HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 00'23'02" E
PASCO COUNTY, FLORIDA.
DO NOT SCALE THIS PRINT. DIMENSIONS AND
ON LOT AREA CALCULATIONS NOTES TAKE PREFERENCE.
LOT = fi890.23_SQ. FT.LIVING AREA = FT. ALL DATA SHOWN HEREON BASED ON THE
_ 1538 �SQ.
ENTRY =_3?--SQ. FT. ENGINEERING PLANS OF KIMLEY-HORN AND
GARAGE =_406__SQ. FT. ASSOCIATES, INC., PROVIDED BY LENNAR HOMES.
COVERED LANAI = A---SQ. FT. ��
PATIO = 23 ---SQ. FT. II " = 10' PUBLIC UTILITY EASEMENT
CONC. DRIVE = 337 ---SQ. FT.
A/C & CONC PAD =9--_-SQ. FT.
PRIVATE SIDEWALK =_72 --SQ. FT.
IMPERVIOUS
= 2717 -SQ. FT.
SOD =_41�3 SQ. FT.
OFF LOT AREA CALCULATIONS
RIGHT OF WAY =_66619 SQ. FT.
DRIVE APRON = 144---SQ. FT.
PUBLIC SIDEWALK = 332---SQ. FT.
SOD = 391_-_SQ. FT.
TOTALS
AREA =__7777.02 SQ. FT.
DRIVEWAY =_ 4B1_SQ. FT.
SIDEWALK =_ 404---SQ. FT.
SOD =_4564 SQ. FT. \
PRELIMINARY DRAWING: �
THIS PLAN IS FOR PERMITTING PURPOSES
ONLY, NOT FOR CONSTRUCTION. VERIFY
ALL DIMENSIONS BEFORE ANY CONSTRUCTION.
LOT 295
LEGEND: LOT 304 gal
-vwa• = PROPOSED DRAINAGE FLOW ��0 .•:yes C�
(00.00) = PROPOSED GRADE �0 00
E-00.00 = EXISTING GRADE \�0 y9
o ati• 0\0
NOTES: �' �° . .•::?' kp
LOT GRADING TYPE = A 165 O
PROPOSED PAD ELEVATION = N/A rprL v v'j
FRONT SETBACK = 20' LOT 303
SIDE SETBACK 10' pd
�REAR SETBACK = 10' rr e��9 .¢
d_ S c�9 b p0.o
l�o'�al \ .:�. � ApA °° v3 ,goy°,.••' �
\ C2_1'9 0iP
°o y c^� LOT 297
\ •,C� . e�
S�.
06
ILO. 0
ti s
LOT 302
n�
Q `o.
\
PROPOSED:
LOWEST FLOOR ELEVATIONS:
LIVING AREA: 71.75'
GARAGE AREA: N/A
ELEVATIONS REFERENCED TO
NATIONAL GEODETIC VERTICAL
DESCRIFMON: DATUM OF 1929. MEAN SEA
3 LOT 303, MAP OR PLAT ENTITLED "HIDDEN LEVEL= 00.00 FT.
� RIVER PHASE 2", AS RECORDED IN PLAT BOOK
CURVE RADIUS ARC CHORD BEARING DELTA
079, PAGES 102 THROUGH 110, OF THE PUBLIC C230 330.00' 21.67' 21.66' S 29'36.01" E 03-45-43"
RECORDS OF PASCO COUNTY, FLORIDA. C231 440.00 28.e9' 28.88' N 29'36'01" W 03'45,_
W
a APPARENT FLOOD HAZARD ZONE: �X" COMMUNITY PANEL NO. 12101C 0458 F EFFECTIVE DATE: 09/26/2014
Square Feet: 6890.23 f LENNAR HOMES
LEGEND:
w (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C AIR CONDITIONER, B/C= BACK OF CURB, C/S=
o CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE-OF PAVEMENT, ESM'T= EASEMENT,
= F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D=FOUND NAIL & DISK, FPP= FOUND PINCHED
N PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT,BOOK, PCP_ PERMANEFT,CONTROL POINT, PRM= PERMANENT
N REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493,' SN&D= SET-AIL &'DISK 14o.4493, TBM= TEMPORARY
= BENCHMARK U P= UTILITY POLE W F= WOOD FENCE _
JOHN R.BEACH&ASSOCIATES,INC. Drawn By:
z SMS -
� SURVEYORS AND MAPPERS Checked By:
911 WEST ST. PETERSBURG DRIVE Chec hec
v ONE
OLDSMAR, FLORIDA 34677 JRB
v WAY Scale:
(813) 854-1276 FAX (813) 855-8370 1"=30' djJL
o NOT VALID WITHOUT ORIGINAL SIGNATURE Date: PLOT PLAN 05/15/2020 RTM — Qs SGo20
AND SEAL OF A FLORIDA LICENSED rFL
A RE D E
M SURVEYOR AND MAPPER N R. EACH _
Revisions: N1DA R V. LAND SURVEYOR'No. 2984 LB 4493
ut M. HA LEY. ' .•'
l7 FESSIO SURVEYOR & MAPPER No.7123
J-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Ae Received JUN 0 9 2020 Phone Contact for Permitting 813 363 2891
.-1-1-1-1-1-1-� --
Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name I N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 3046 Lytton Hall Drive LOT# 0303
SUBDIVISION Hidden River Phase 2 PARCEL ID# 24-26-21-0110-00000-3030
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED II./ II NEW CONSTR e ADD/ALT SIGN Q DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR 0 COMM OTHER
TYPE OF CONSTRUCTION BLOCK Q FRAME 0 STEEL Q
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 2276 SQ FOOTAGE j HEIGHT 1 Story
��✓ BUILDING t V(,04 VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ AMP SERVICE ® PROGRESS ENERGY Q W.R.E.C.
PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION ���
=GAS P11 ROOFING Q SPECIALTY 0 OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES I u o
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4600 W.Press St.Ste. ,Tampa,FL 33607 License# FCGC1518166
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 1034 SkipWr Road,Tamp 33613 License# EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 8, Bayo et, 34674-5308 License# I CFC042998
MECHANICAL COMPANY Bayonet Plumbing,"Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N
Address I P.O. Box 5 , Bayo et, F 34674-5308 License# I CAC058062
OTHER COMPANY KSterling Quality Roofing, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4211 Shoal U e Blvd, Spring Hill, FL 34607 i License# CCC057991
111111111111111 111111111111111111111111111111111111111111111111111
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
I�... .... ..rl.l..1.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
"* Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of'all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is,considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YO N ND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR N ATTORNEY BEFORE RECORDING YO RMOME OF COMMENCEMENT.
FLORIDA JURAT(F.S. 117.�
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to( aff )before me this Subscribed and o or affirmed)before me this
L4—HPf—LU by Ashlee a ahan 24-Apr-zo by Ashlee Callahan
Who is/are personally known to me or hasilhave predUGed Who is/are personally known to me or
s identification. as identification.
Notary Public ry Public
Commission No. FF985637 Commission No. FF985637
Elissa M.Holleran Elissa M.Holleran
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
_�"""' E4111�14N.W�6Lt�,4hN -�•.�, Et19Sl+N.PIOLIEANIV
�,�irm':l�.'anu�t'R9dl077 + a;�lIP1r1"�L'�fl11r�P®078J�
'+�!� ��ldn��r. t��1,NZr�r�r�s��W�nas�fi'Kalls�+►1
Q
Single Family Dwelling
Plan Review Comments
1. F:F.E shall be a minimum of 8" above;,the road elevation and an engineered site plan.
2.. Lots shall.be graded to.comply with.R401.3 of the_F:B.0
3: Compaction test required if 247.or more.of fill dirt is brought in at any one place.
4: Tie in survey required-before.pouririg concrete: .
5. Driveways require a R..O:W use permit: All 4 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
-7. All.properfymarkers shall be uncovered.'and marked at time of first inspection...
& All A:D.A. requirements shall be_met:
9-. No electric,plumbing,mechanical,or.framing shall be:covered without an inspection.and
approval first.
106 All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation):
I.I. Appliances s.hall.notbe installed in a location.where_subject.to mechanical damage unless-
protected by approved barriers. M303.4.of the F B.0
12. Water heaters shall comply with section P607.3 ofthe F.B.C.
13. Foundation supports for A/C units..shall be raised at least 3" above finished grade. M1308A. .
14. Return air in.all bedrooms. F.B.C. M1620.4
15. Smoke'detectors are to be installed in accordance with R313:1 of the F.B.C.
16..All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means.of egress are to be in accordance with R3-11 of the F.B.C.-
18."Green.gypsum.board'.' shall riot be used as a baekerin showers or tubs. R702:4:2 F.B:C.
10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required iri new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all
underground:plumbing and electric.
22. All 2016 N.E.C. Codes will be enforced.
23. Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E:C
24. 1h accordance with the Land Development Code, lots.shall be sodded before final of least 10
-
feet around the structure:
25. R403.5.3Hot water pipe-insulation.
Insulation for hot water-pipe-with a minimum-thermal-resistance (R-value) of R-3 shall.be applied to the
follow- in
Piping.j,inch (19.1 mm)and larger in nominal diameter.
Piping serving more than one dwelling unit:
Piping located outside the conditioned space.
Piping from the water heater to a distribution manifold:.
Piping located under_'a floor slab:
Buried in piping,
Supply and return piping in recirculation systems other than demand recirculation systems:
25. Blower.door test shall be provided:before C.O:
.26. A copy of the energy cacls shall be=with permit at all times
27.. Copp of final insulation-report-shall be provided with permit before final
28:No fence, pool or screen enclosure :is issued with:thisPermit.
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 6 h Edition
R.O.W.-Right of Way
A.D:A.=:Americans with Disabilities Act N.E.C.-National Electric Code (2016)
Lennar Homes-3046 Lytton Hall Dr.-2,276 sqft
Column Es
' SQ. FEET PRICE
MAIN OR LIVING: 2,276 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 256,391.40
FEE SHEET $ 1,325.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,426.50
ELECTRICAL: $ ! 298.13
PLUMBING: $ 198.75 i
MECHANICAL: $ 139.13
SUB-TOTAL $ 2,062.50
TOTAL $ 2,062.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,189.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 8,328.00
100.0% $ 8,328.00
1.0% $ 83.28
TOTAL: $ 8,411.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 19,002.47