Loading...
HomeMy WebLinkAbout20-315 Fca`nue PERMIT NCJMBER.City Of ZephyrhillS •,: . r' ... ty :`� 5335 Eighth Street Zephyrhills, FL 33542 BGR-000315-2020 Phone: (813)780-0020 Issue Date: 07/14/2020 Fax: (813)780-0021 Permit Type: Building General (Residential) Property-Number Street Address 02 26 210180 00000 0570 6101 17Th Street St Owner Information. Permit Information Contractor Information Name: CHAD BOLENDER Permit Type:Building General(Residential) Contractor: PAUL D. SCHAPER Class of Work:Reroof CONSTRUCTI INC Address: 6101 17Th St Total Valuation:$1,750.00 ZEPHYRHILLS,FL 33542 Total Fees:$73.13 Phone: (813)312-8151 Amount Paid:$73.13 Date Paid:7/14/2020 2:29:11 PM �J Project Description REROOF TPO Application Fees Building Plan Review Fee $24.38 Building Permit Fee $48.75 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CTOR SIGNATURE PE IT OFFICE <4'ERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills.Permit Application Fax 513-7s0-0021 Building Department / Date Received �p--�. eP�hone:Contact.foaPermitting, 2 Q Owner's Name ®\�n.��C.V ' OwnerPhone Number f JI ''U S �� 66aaC 2 Owner's Address : � `► 6(I 1 J � � Owner,Phone Number. - Fee Simple Titleholder Name. Owner.P.hone•Number. ' Fee Simple Titleholder Address` JOB ADDRESS 1� ` I JZ t`�J �1 1� LOT# , SUBDIVISION (� F' 1\ PARCEL ID# tv. -t 1. ® " (OBTAINED;FROM PROPERTY TAX NOTICE). WORK PROPOSED 'NEW CONSTR; ADD/ALT Q SIGN. DEMOLISH . ... INSTALL R. REPAIR: PROPOSED USE 0 - -SFR ,_. .'COMM.- 0: OTHER TYPE OF'.CONSTRUCTION .0 BLOCK -FRAME- STEEL 0 DESCRIPTION.OF WORK 1v CAW O 1 BUILDINGSIZE SQ FOOTAGE= HEIGHT.- =BUILDING:'. $ VALUATION OF TOTAL-CONSTRUCTION =ELECTRICAL: $ AMP-SERVICE- = PROGRESS-ENERGY. :0 W.R.E.C. . =PLUMBING $' =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ®/'ROOFING Q SPECIALTY 0 OTHER FINISHED'FLOOR ELEVATIONS' ' FL"OOD ZONE AREA =YES NO :BUILDER COMPANY. Q t90� SIGNATURE ((�� REGISTERED /-N'- FEECURREN /•-N Address. "1 ��, A\( ',111W1 License.# CCC-FZk3N ELECTRICIAN COMPANY - SIGNATURE' REGISTERED, -Y/;N FEE•CURREN... .Y/N Address License# . PLUMBER.. COMPANY ,SIGNATURE :REGISTERED :Y/ N' , FEE-CURREN Y/w Address •'License#'- MECHANICAL COMPANY. SIGNATURE' REGISTERED. Y./•N "FEE:CURREN Address License# OTHER COMPANY, SIGNATURE ,REGISTERED. Y.•/'.N :FEE.CURREt. Y/N. Address.. License#- - ,:. RESIDENTIAL Attach(2•)?PIot:Plans of.'Buildlhg P.-:lans;(1)set of;Energy,,Forms;,R-0.WPermit-for.newtconstruction, _Minimumaen('10)_working days after-submittal date:._.equired-onsite Construction Plans,Stormwater_-P-lansw/Sllf-Fence installed, Sanitary Facilities&1-dumpster,:Site Work Permit,forsubdivisionsAarge projects COMMERCIAL Attach:(2).complete sets;of Building:Plans;plUs�a1ife':Safety,P age;..(1).set of.Energy.Forms..R-O=W Permit for.new construction:,: Minimum•ten'(1.0);Working days;after=submittal:date :Required-.onsit i-.ConstrucUon'Plansi:Stormwater:Plans,w/Silt'Fence installed, Sanitary,Facilities.,&'1-dumpster.Site Work Permit:for:all new..projects::AII'.commercial.requirements must'meet compliance-. SIGN PERMIT Attach(2)-se6 ofEng(neer'ed:Pians: "•"'PROPERTY`SURVEY:required.for.all.NEW-construction. �'IDlrections: ' Fill.out.application completely. Owner&Contractor;sign,back of application,notarized If over$2500"a Notice of CommenceMent is required: (A/C upgrades over$7500) Agent(for•the contractor)'or Power of Attorney{for the owner)would'be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy.of contract'required) Reroofs if shingles Sewers Service'Upgrades..A/C: .<Fences(Plot/Survey/Footage) -• Driveways-Not over Counter if on pubiic;roadways:.needs ROW NOTICE*OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which maybe more restrictive than,County regulations. The undersigned assumes responsibility for comp!iancewith any applicable.deed.restrictions. UNLICENSED:CONTRACTORS''AND- CONTRACTOR 'RESPONSIBILITIES: Ifthe owner 'has hired si,contractor or contractors to undertake work, they maybe licensed-in accordance with-state and local.regulations. If the contractor is.not licensed as.required by law,.both theowner and,contractor maybe cited for a misdemeanor violation under.state law. If the owner or.intended­contractor.�are uncertain as to what licensing requirements may apply for the intended work,they are advised t6.,-'contact the Pasco County Building'Inspection Divislon—Licensitig Section at 727-847- 8009. Furthermore,.if the owner.has,-hired 1--a-­contractor or contractors, he is advised to have the-contractor(s) sign portions-of the "contractor Block" of.,this..application for which they will be responsible.. If you,.as the owner sign as the contractor, that may be:an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County,TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: 'The undersigned understands that Transportation:]mpact Fees-and Recourse.-Recovery Fees,-may,apply,to the­construction.of-new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance-number 89-07 and 90-07--as,amended, The undersigned,also. understands,-that such fees; as maybe due,will-be identified-at the time of permitting. It is further und6r-stooid'that.Transp6r.tation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certifidate of occupancy" or final power-release. If thepripjdict does1idt`ihv6lve a certificate of occupancy or final power release, the fees must be,paid prior to permit issuance. 'Furthermore, if-Pasco County-Water/Sewer Impact fees are.due,.they,must-be_paId_.priori.tQ_permit issuance in,accordance;m(ith applicable Pasco County,ordinances. CONSTRUCTION'.LilEN'LAWI (Chapter 713i'Florlda Statute,$, as amended), 'Ifvaluation,of work.-i8.$2,5.00:00aormore, I" certify- that li the.­applicant,,-have..--been--provided-with a.copy of the "Florida -Construcfion--Lien. Law—Homeowner's Protection Guide" prepared*by the Florida.-Department of Agriculture and Consumer Affairs. If the applicant,is someone other than the"owner" 'I cer-tify.that l,-have-obtained a copy of the,eibove described document and promise,in good faith to deliver it to the"own prior to commencement. CONTRAC,,T�.OR?,$/O.WMERIS,,4FFIDANIT:"I certify.,that all-the infotmatiqln-in this catioP Is�a accurate,and that.all', ork ppli will be done in compliance-With all applicable laws regulating construction, z6ning-land-landdeveiopment. Applicatlonr�iS, hereby made to obtain a permit to do work and-installation as 'indicated. Fcertify that no work.or installation has commenced prior to.,issuance of-a permit and that all work will- be performed to meet standards of all laws regulating construction,'County-and City-codes,.zoning regulations, and land development-regulations in the jurisdiction. -1 also. certify that 1,understand that the regulations of other government agencies may apply-to.the,,intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include-butare not limited,.to: Department of Environmental Protection-Cypress Bayheads, Wetiand:.Areas-and Environmentally Sensitive Lands,WaterMastewater Treatment. Southwest* Florida Water Management District-Wells, Cypress', Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health. & Rehabilitative Services/Environmental Health-_Unit­Wells, Wastewater,Treatment,, Septic-Tanks. U-S*°Ehvir-.Onmental,=Protection--Agency-;Asbestos-abatement..,- Fbddr9I-AvI9tibn Authoirity-�Runways. . I I understand that*,th6---followlng restrictlops,apply to-the use of,fill. Use of-..'fill'.is.-,,not.allowed,,ih:'FloodiZone.*"V.'unless expressly permitted.. lfthe':fill.-thaterial'is to be used in Flood Zone:"A';' it is understood that a drainage plan addressing a !'Compensating volume!' will"be*-submitted at time of-permitting­which-is,.prepared-by a professional engineer Iic6nsed:bth y, e State of Florida. : lf*,th-.etfill.,.m.a.terial,,is---to.-be,.used.'in..Flood,.Z6ne "A`!Wconnection with a permitted building using step wall -con$.ttuctidni,-.t-certif�.,that'filI will be,,-used-only to fill the area within-the-stem wall. if--fill, material: is to .be., used in any area,.I certify that use of such fill .will not adversely affect adjacent .prop.erti0s­.;,:1lf:use-of.,fill.is found to.adversely affect.adjacent properties;,-the.-.owner,,may-be,cited for violating the-conditio' ns of building,permit issued Under the attached permit application, for lots less than one (1), p acrevbich,�ara Blevated.,by.fill;-an,engineered drainage.`Ian i&,required. If I am.the,AG,ENT,,.-,�'P&kiNE�OWhE�k, I promise,in good'faith to inform.the owner.of1he-permitting conditionsset forth in this affidavit;-prior..*.to commencing construction. I understand that a separate permit may be required for electrical work-, plumbing',r:signs,w6ilS' ,i:-p0ols,'t:,aJrt conditioning.,--gas,.-or­,other installatldhs-.not specifically included in-the-applicatio". A permit issued-shall be:construed to-be a license to proceed Withthe-work.,and not as authority to violate, cancel, alter,or set aside.-,:Ony,.proVitionst6f,.thei-tedhnidai;,codes,-:nijt,thall'issuanceota permit prevent the Building Official from thereafter requiring.a,,c.orr,ecti.on-of-errors--in plans, construction or violations-of any codes.,-'Every­permit issued-,shall-become invalid unless the,work,authorized by,such Permit is commenced within six months of,permit issuance, or if work authorized by thb Perm:it1Is,suspe'ild6d`or abandoned for a:period of six-.(6)months after the time the work Is commenced'i An extension may be-requested,-.in-writing,"from the Building.Official for a period--!.not to exceed ninety(90) days and will demonstrate justifiable 'cause fonthe extension:­lfwotk ceases.,fdr ninety(90)'=consecutive days,the job,is,considered,abandoned. WARNING TO.OWNER-.,- YOUR--1'FAILURE-TO RECORD A NOT-ICE-OF-COMMENCEMENT-.-MAY-.,RESULT, IN YOUR :'PAYING"TWICE FOR,';IMPR'OVeEMENTS`Ta"YOURPRt)P-.ERTYI!41F'YOU"INTEND,'TO*°•;013TAiN"FIN-At4CIN,G;CONSULT WITH"YOUR�LENDER70R-AN�A-�T-!TORNEY`6E�'CkE.-,KEC"ORDING-.Y-0,UBWQlMg2Ejg- 'CEMEt4-T. FL,ORIDA-JUR'ATI(F."S.-ii7ju�- . , OWNER(Av--7AGENT ,, ht -ilO D -CONT Subscribedand swc)TnAia, -Wi67 me this OF-51IIAo rWindWis� Subscdbed�'and-sw6m?tt,-(Zyr-af&n6d)-,bi bV \Pq�xm Who is are personally known to 7_x�has/hhve produced Who Istire ersonally kno sthaie.produced - er r, m to me I Z nt[ficaflon. -as Idenfiftaflon. Nota Public Notary Public Commission No. Commission No. 004 A -0 A 04 A 00%, a 'N L Name lYP4t04rAWi`R?1RFKrid Name,ofN ry_4.�_p-d- -I -86rTt1nne-8- pr 0 ry PUbfic fate of Florida �s W10 W _t 0 e 12 !t ann ' Alicia Herweh-Cannon Alicia Herweh-Cannon e My Commission GG 218378 MY Commission GG 218378 Expires 05116/2022 41, Expires 05116/2022 CW IV OF .t re ' EXTERIOR RESEARCH&DESIGN, LLC. Certificate of Authorization#9503 .1 1 ERD 353 Christian Street Oxford,CT 06478 (203)262-9245 EVALUATION REPORT Mule-Hide Products Co., Inc. Evaluation Report M15060.06.09-R5 1195 Prince Hall Drive;Suite A FL12772-R5 Beloit,WI 53511-5481 Date of Issuance:06/24/2009 (608)365-3111 Revision 5:09/11/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the Stbte of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 61h Edition(2017) Florida Building Code sections noted herein. DESCRIPTION:;:Mule=Hide�TPO=e'-,Single.Piy}:Ro_o,.f;Systems:r LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named prod uct(s).changes,the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a.complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 27-page Appendix. Prepared by: Robert J.M.Nieminen,P.E. : _ The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No.59166,Florida DCA ANE1983 P.E.on 09/11/2017.This does not serve as an electronically signed .1✓+r'�rau�'tq�sN document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research&Design,LLC,d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued: 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial Interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitvIERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. JUN ALL WORK SHAi L COI�PftY WITH PREVAILING REVIEw oATE CODES FLORID.A SULDING CODE, CITY OF ZEPHYRF�' NATIONAL ELECTRIC CODE, F'L�4N ENBiNER AND THE CITY OF ZEPHYRHILLS ORDINANCES TRIN'IT*�ERA ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Single Ply Roof Systems Compliance Statement: Mule-Hide TPO-c Single Ply Roof Systems, as produced by Mule-Hide Products Co., Inc. have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.13.2 Physical Properties ASTM D6878 2011 1523.6.2 Wind TAS 114 2011 3. REFERENCES: Entity Examination Reference Date ACRC(TST4671) TAS 114 07-051 08/29/2007 ACRC(TST4671) TAS 114 07-059 10/15/2007 ACRC(TST4671) FM4470 10-009 05/19/2010 ACRC(TST4671) FM4470 11-035 06/28/2011 ACRC(TST4671) FM4470 10-018 08/25/2010 ACRC(TST4671) FM4470 10-019 08/25/2010 ATI(TST1588) FM4470 01-37050.01 03/13/2b00 ATI(TST1588) TAS 114 D7772.01-109-18 07/09/2014 AT[(TST1588) TAS 114 D7772.02-109-18 07/14/2014 CTL(TST 1577) TAS 114 CTLA-105R 10/13/2008 CTL(TST 1577) TAS 114 CTLA-105R-1 10/13/2008 CTL(TST 1577) TAS 114 CTLA-10511-2 16/13/2008 CTL(TST 1577) TAS 114 CTLA-106R 10/16/2008 CTL(TST 1577). TAS 114 CTLA-10611-1 10/16/2008 CTL(TST 1577) TAS 114 CTLA-10611-2 10/16/2008 CTL(TST 1577) TAS 114 CTLA-10611-3 10/16/2008 CTL(TST 1577) TAS 114 CTLA-106R-4 10/16/2008 CTL(TST 1577) TAS 117 CTLA 111R 01/13/2009 ERD(TST 6049) FM4470/FM 4474 02764.09.05-111 12/10/2007 ERD(TST 6049) FM 4474 M5830.10.07-R1 01/23/2009 ERD(TST 6049) FM 4474 M30780.09.09 09/23/2009 ERD(TST 6049) Physical Properties A35880.04.12-R1 10/26/2012 ERD(TST 6049) Physical Properties C46470.07.14-1A 07/16/2014 ERD(TST 6049) Physical Properties C46470.07.14-113 07/16/2014 ERD(TST 6049) Physical Properties C46470.07.14-4-R1 07/21/2014 ERD(TST 6049) Physical Properties C46470.07.14-2A- 07/30/2014 ERD(TST 6049) Physical Properties C46470.07.14-213 07/30/2014 ERD(TST 11294) FM 4474 13380.01.17 01/27/2017 ERD(TST 6049) Physical Properties CRL-SC14240.17 03/21/2017 ERD(TST 11294) FM 4474 CEL-CLT16160.08.17-1 08/28/2017 ERD(TST 11294) FM 4474 CEL-CLT16160.08.17-2 08/28/2017 FM(TST1867) FM4470 OV7A4.AM 06/16/1992 FM(TST1867) FM4470 3Z9A1.AM 10/15/1997 FM(TST1867) FM4470 3001522 03/26/1999 FM(TST1867) FM4470 3003393 03/30/1999 FM Approvals(TST1867) FM 4470 3012879 04/04/2003 Exterior Research and Design,I.I.C. Evaluation Report M15060.06.09-R5 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL12772-RS Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Revision 5:09/11/2017 Page 2 of 4 1 .—.` Kati �y :►�TIITY ERD Entity Examination Reference Date FM Approvals(TST1867) FM 4470 3013584 06/27/2003 FM(TST1867) FM4470 3014692 08/05/2003 FM(TST1867) FM4470/FM 4474 3017662 06/07/2005 FM(TST1867) FM4470/FM 4474 3023032 07/20/2005 FM(TST1867) FM4470/FM 4474 3020845 01/25/2006 FM Approvals(TST1867) FM 4470/4474 3023458 07/18/2006 FM(TST1867) FM4470/FM 4474 3022174 09/25/2006 FM Approvals(TST1867) FM 4470/4474 3026964 07/25/2007 FM Approvals(TST1867) FM 4470/4474 3029940 09/08/2008 FM Approvals(TST1867) FM 4470/4474 3034985 12/15/2008 FM Approvals(TST1867) FM4470 3037400 09/02/2009 FM(TST1867) FM4470 3037525 09/25/2009 FM(TST1867) FM4470 3037770 10/22/2009 FM Approvals(TST1867) FM4470/4474 3036762 03/08/2011 FM Approvals(TST1867) FM4470/4474 3041535 06/08/2011 FM Approvals(TST1867) FM4470/4474 3039340 06/24/2011 FM Approvals(TST1867) FM4470/4474 3039762 09/07/2012 FM Approvals(TST1867) FM4470/4474 3056207 02/09/2016 FM Approvals(TST1867) FM 4470/4474 RR209155 04/03/2017 PRI CMT(TST5878) TAS 114/FM 4474 CST-016-02-01 05/04/2011 UL,LLC(QUA9625) Quality Control MLA;R13850 08/22/2007 UL,LLC(QUA9625) Quality Control Inspection Report 06/01/2017 4. PRODUCT DESCRIPTION: The following roof covers are mechanically attached or fully adhered to Approved substrates using fasteners, stress plates and adhesives,as outlined in the Limitations/Conditions of Use herein. 4.1 Mule-Hide TPO-c membranes are nominal 45-mil (1.1mm) or 60-mil (1.5 mm) thick, polyester-scrim reinforced,thermoplastic olefin(TPO)single-ply roof membranes. 4.2 Mule-Hide TPO-c EXTRA membranes are nominal 72-mil (1.8mm) or 80-mil (2.Omm) thick, polyester-scrim reinforced,thermoplastic olefin(TPO),single-ply roof membranes. 4.3 Mule-Hide TPO-c Fleece Back membrane is a nominal 45-mil (1.1mm) or 60-mil (1.5 mm) thick, polyester- scrim reinforced,thermoplastic olefin(T130)single-ply roof membrane with a pblyester fleece backing. 4.4 Mule-Hide SA-TPO membrane is a nominal 60-mil (1.5-mm) thick, polyester-scrim reinforced, thermoplastic olefin(T130)single-ply roof membrane laminated to an elastomeric pressure-sensitive adhesive. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current UL Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations,foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations,the existing roof shall be examined in accordance with FBC 1511. Exterior Research and Design,I.I.C. Evaluation Report M15060.06.09-RS Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION. FL12772-R5 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Revision 5:09/11/2017 Page 3 of 4 e \\ TRN1Ty ERC I . 5.7 For mechanically attached insulation or membrane or strip-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1.29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.8 For.assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted.for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX- 1 or Testing Application Standard TAS 105. 5.10 .For bonded insulation or membrane over existing substrates in a re-roof(tear off) or recover installation,the existing deck or existing roof surface shall be examined for compatibility with;the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane.over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment(except gutters),shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111,except the basic wind speed shall be determined from FBC Figure 1609.3(1),1609.3(2)or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 611320-3. 6. INSTALLATION: 6.1 Mule-Hide TPO-c Single Ply Roof Systems shall be installed in accordance with Mule-Hide Products Co., Inc. published installation instructions,subject to the Limitations/Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 6.3 For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed running perpendicular to steel deck flutes. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered to F.A.C.Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com -THE 27-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report M35060.06.09-RS Certificate ofAothorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL12772-RS Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Revision 5:09/11/2017 Page 4 of 4