Loading...
HomeMy WebLinkAbout20-320 ' D City of Zephyrhills RMIT PENUMBER 5335 Eighth Street Zephyrhills, FL 33542 BNR-000320-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 47l31/2020 Permit Type: Building New (Residential) Property Number Street Address- 32 25 21 0100 01800 0270 35525 Stella Vast Dr Qwner information Permit Information Contractor information Name: D R HORTON Permit Type:Building New(Residential) Contractor: D R HORTON INC Class of Work:SFR Construct Address: 12602 Telecom Dr Building Valuation:$105,000.00 TAMPA,FL 33637 Electrical Valuation:$7,000.00 Phone: (813)549-1968 Mechanical Valuation:$7,500.00 \� Plumbing Valuation:$5,000.00 Total Valuation:$124,500.00 Total Fees:$14,599.94 Amount Paid:$14,599.94 1 �✓ "" Date Paid:7/30/2020 4:28:49PM Project Descnpfton CONSTRUCT SINGLE FAMILY 2,362 SQ FT Application Fees Address Fee $30.00 Driveway Fee $45.00 Transportation Impact Fee-City $36.32 Mechanical Permit Fee $77.50 Mechanical Plan Review Fee $38.75 Electrical Permit Fee $75.00 Electrical Plan Review Fee $37.50 Park Impact Fee-Single Family/Townhome $769.56 SIF 1 percent Fee $83.28 School Impact Fee $8,328.00 Building Permit Fee $565.00 Plumbing Plan Review Fee $32.50 Plumbing Permit Fee $65.00 Public Safety Impact Fee-Police $254.00 Transportation Impact Fee $3,595.68 Public Safety Impact Fee-Fire $273.00 Public Safety Impact Fee-Admin $26.35 Building Plan Review Fee $277.50 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances.NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. l CONTRACTOR SIGNATURE PE r IT OFFICE PERMIT EXPIRES IN G MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE111114 FOR OF ' 1 BILLING CONTACT DAVID GLIDE D R HORTON INC 12602 TELECOM DR TAMPA, FL 33637 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00000419 07/29/2020 07/29/2020 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-000320-2020 Address Fee $30.00 Building Permit Fee .�2,� $555.00 Building Plan Review Fee V $277.50 Driveway Fee $45.00 Electrical Permit Fee I Z,�'� $75.00 Electrical Plan Review Fee I l / $37.50 Mechanical Permit Fee �'���� $77.50 Mechanical Plan Review Fee $38.75 Park Impact Fee-Single Family/Townho�m.,el $769.56 Plumbing Permit Fee l �` $65.00 Plumbing Plan Review Fee $32.50 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Fire $273.00 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 SIF 1 percent Fee $83.28 Transportation Impact Fee $3,595.68 Transportation Impact Fee-City $36.32 35525 Stella Vast Dr Zephyrhills, FL 33541 SUB TOTAL $14,599.94 REMITTANCE INFORMATION TOTAL $14,699.94 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 n /� � V July 29,2020 `5335 8th Street,Zephyrhills,FL 33542 vPage 1 of 1 City of Zephyrhills Perrryl`.Application Fax-813-780-0021 Building Departrnent'•. - Date Received Phone Contact for Permitting I- -I-rr Owner's Name �nc Owner Phone Number lctu I Owner's Addressl a_(ac2,.:Wccclmhr J-hamon 33013r- Owner Phone Number F Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS LOT# I V SUBDIVISION t`Jemcko PARCEL ID#137 ?_I 01ho' 6jSM 0 2--tT) (OBTAINED FRONT_PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTRR ADD/ALT SIGN E=1 DEMOLISH E� INSTALL REPAIR PROPOSED USE = . SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK imlig (�wdm re--,-A BUILDING SIZE SQFOOTAGE�M HEIGHT Anna .. . . . . . . . . . . . . . . . . A=BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL 1$ AMP SERVICE 0 PROGRESS ENERGY = W.R.E.C. =PLUMBING $ �Q\0 0 =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATIQN 3?;o =GAS ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS 3 UFLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED FEft CURRES L]L/N Address License# FcBcb sc%:z ELECTRICIAN COMPANY , Elm a P Elerfi:i C SIGNATURE REGISTERED Y/ N I - FEE CORREN I Y7 N Address r License# I Ec. 0 633:1 S... ..... ...... PLUMBER COMPANY . 5Chknq-,1 plomb;-I SIGNATUREr- (A REGISTERED Y/ N 'R.EECUkR t\ I Yl N Address 147-11 T( Licent5e# FE�Z6(4 MECHANICAL. COMPANY Ike SIGNATURE 5-q 0 REGISTERED f -f/•N FEE CURREN �N Address 0 We OrA Llcense# I CA- co 33 5 OTHER COMPANY Hcoxvm 2061�- SIGNATURE REGISTERED 0FECURkEK *1 Y/N Address F714 3 4V Npapab&ui \M�31 License# Ea:l -S-,8 3 3- 11111111111111111 I 'll 1111111 livill 111111 111 111111 111 111 111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans,,(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required o-nsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumoster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions:_ Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone With notarized letter frorp owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)" Driveways-Not over Counter if on public roadways..needs ROW � NOTICE OF DEED RESTRICTIONS: 7y,b undersigned'----�— understands that this permit may be subject bz"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. . UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hirdd' e -contraotor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. \fihe contractor is not licensed as.required by law, both the owner and contractor May be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing.Section ot727-847- 80UQ. Furthernnmra, if the owner has hired 8 contractor or contractors, he is advised to have thb contractor(s) sign portions of the "contractor B|od/' of this application for which they will be responsible. If you, as the owner sign as the oontrootor, that may be an indication that he is not pnnpedy]\oensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION YA8PACT7DTILIT\I�S IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new bui|dings, change of use in existing buUdinga, or expansion ofaristinQ buildings, as specified in Pasco County Ordinance number 8Q'O7 and QO-OT' as amended. The undersigned also undersbando, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees'and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy' o,final power release. If the p � '�ctd0eanot \nvo|v� � �� ifiootaofuccuponcyor final no| power.re|ease. the fees must be paid prior to permit issuance. Furthermore' if Pasco County VVaterlsevvar Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, F\orida Statutes, asarnendod): |f valuation of work|e $2.5OO.00or more, \ certify that |. the epp|\cont, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver|tto the"cwvner"prior kzoo0meftemeOL CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all epR)ivab\n }ovvs regulating conatruoUon, zoning and land development. Application is hereby made to obtain o permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all |avva regulating construction, County and City codes, zoning regulations, and land development regulations (nthe jurisdiction. | also certify that | understand that the regu|dt|ono of other government agencies may apply to the intended work, 'nd that it is nny[oopoDoibUUotoideDt�vvvhsdaoUons | nnuat take bzbe|ncompliance. Such agencies iDdudebut are not|irnitedto: - Department ofEnv|ronme0tm Protection-Cypress 8ayhaada' VVed|and Areas and Environmentally Sensitive Londe.VVaban/Waatexvaterrroatment. ' - Southwest Florida VVatal' Management [}iobict4NaUe� Cypress Boyhaodo, Wetland Areas, AlteringWatercourses. ' - Army Corps ofEnginee Docks, Navigable Waterways. ' Deportment of Health 8 �ehabU|tmtive Serv|cee/Env|ronmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - U8 Environmental Protection Agency-Asbestos abatement. - Federal Aviation Author|tx'Runvvays. \ understand that the following restrictions apply to the use Vffill: ' Use nf fill ia not allowed inr(bod Zone"V"' un|esa expressly permitted. ' If the fill hnatahai is to be used in Flood Zone "A"' it is understood that a drainage plan addressing a '"connpenoat\ng vo'u0e" will be submitted at time of permitting which is prepared by a professional engineer UoeOaodby the 8tabsofFlorida. - If the fill*material is to be used in Flood Zone "/Y' in connection with a permitted building using stem vva|| construction, | certify that fill will be used only to fill the area within the stem wall. - If fill 0ainhe\ is to be used in any area, | o8rdfv that use of such fill yvUi not 'adversely affect ad|oo8Ot properties. If use of fill in found to adversely affect adjacent properties, the mVvnar may be cited for violating the conditions of the buildlng permit issued under the attached permit application, for lots less than one (1) acre which are elevated b?fiU' an engineered drainage plan is required. If } ern the AGENT FOR THE OWNER. | promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that separate permit may be required for electrical vvork, plumbing, oigOo, vve||s, poo|e, air oonditioning, ges, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, no[shall issuance ofo permit prevent the Building Official frorntharaa�er requiring aoornecdoOofennrain plans, ounstnuoUonnr violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six OlOOthS of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. AnfxtenaioD may be requasbod, in vvritiOg, from the Building Official for n period not to eXoaad ninety /90\ days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. . WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT I MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTOF_tNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR AGENT CONTRACTOR Subscribed arfd sworn to(or affirr��d)beforrmg this Subscribed and sworn to(or affirmed)before me this Who is/are p or has/have prodbred Who is/are personally krivvn to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or t d Name of Notary typed,printed or stamped L(pu Notary Public StWe of Florida INSTR#2020105235 OR BK 10 1 29 PG 2994 Page 1 of 1 07/0112020 03:55 PM Rcpt:2177772 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk&Comptroller Permit No. Patrol ID Na NOTICE OF COMMENCEMENT state of Florida county of- Pasco- THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information Is provided in this Notice of Commencement 1. Description of Propartr. Parcel Identification No. LOV 2�I_ (bko0h ke bkklltt_r kk VC) k6o V\ Street Address: 35526 C_A-ftA% %40,% 4t a �A, 335!A 2. General Description of Improvement New Single Family Residence 3. Owner Irlibrmation or Losses information if the Lessee contracted forthe Improvement D.R. Hoftai-Inc . Name 19S119 TPIPmm Drives Tampa 33537 Address CRY state Interest In Property: F8eSoMpie Name of Fee Simple Titleholder. (if different from Owner listed above} Address city state 4. Contractor. D.R. HQrton. ]no Name 12.602 Tel- ecom Drive Tampa 33637 FL Address city state Contractoes Telephone No.: 5. surety: NtA Name Address City state Amount of Bond: S N/A Telephone No., e. Lender. NIA Name Address city State Lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)M,Florida Statutes: David Gude Name 1202 Telpcom Drive Tampa 33637 FL Address CRY State Telephone Number of Designated Person'. 813-740-9720 8. In addition to himself,the owner designates N/A- --- of to receive a copy of the Lleno?s Notice as provided In Section 713.13(t)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner g. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different data is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713 PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR impRovEmENTs TO YOUR PROPERTY. A Notice, OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND To OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of.perjury,I declare that I have read the foregoing once f commencement and that the facts stated therein are fxua to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Sig turn ol Owner or Lessee,or Owneris or Lessee's Authorized officer/Director/Partner/Manager istant 5ecretaWD.R. Horton. Inc-- SignAorys TftlefOfflce The foregoing instrument was acimowtedged before me this_L_day of")CA_2019by 10 trustee,attorney in fact)for as AssLqant Sec=iy __(type of authority,e.g.,officer, DR. Horton, Inc —(narra,of party on behalf,r f orrilris meet was executed). Personally Known JA OR Produced identification 171 Notary Signature L Type of Identification Produced - Name(Print) ONN Matuy Pubfic State of Florida ftbelte Mayes My CommloWn GG W321 ExplresIV21*020 wpdatalbcsinotcecommencomenLpco53D48 PASCO COUNTY, FLORIDA Permit No. r Date Permitted �Buiider Name/Owner Name CD L" Control#• " County Parcel No. b �� 1�rrOC!�,J2?t—O SubDiv: Address/Location 3,56 2-s Classification/Type of Use �t TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z Exempt ❑Ves ❑ No How determined Impact Fee Amount $. 3-.�JD- Zone No. TAZ: ( SCHOOL IMPACT FEE S� q1 Account (056) Single-Family Detached House Amount $ — f—=_�i_{ (057) Mobile Home (056) Other Residential 23) Collection Fee Exempt d Yes ❑No How Determined PARKS AND RECREATION FEE: Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 72 Exempt ❑Yes ❑ No How Determined 'A LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount 4e,> _ RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL.BE ISSUED.OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AmOgNTS usTED HAVE BEEN,PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the building permit owner,on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY PLOT PLAN DESCRIPTICIN:(AS FURNISHED) LOT 27, BLOCK 18, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A AND 11B AS RECORDED IN PLAT BOOK 77, PAGE(S) 79-86. OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Line Table Curve Table Une#I Direatia. ILength Curve#2Length 1Rad iusDelta and Bearing chord LI N8959-20-W 16.96' CI 2442-[55.00' 2538-33" � 1*23-W 24-41, C2 16O.GO. 2358'1rN78`01'31-E 6,tA5.TRACT "ApRIVA SEMENT DRAINAGE EA T S89*59'20"E F- 26.93' LOT 27 1 0 15 30 BLOCK —7.i7rk ii �jALNAGE TYPE C) ON LOT CALCULATIONS 0 LOT = 7.870 SO. FT. LIVING AREA = 1,828 SO, FT. GARAGE = 430 SO. FT. ENTRY = 16 SO. FT. 25. LANAI = 88 SO. Fr. PATIO = 0 SO. FT. DRIVEWAY = 367 SO. FT. I w LOT 26 A/C PAD = 12 SO. FT. T- - BLOCK 18 WALKWAY 28 SO. FT. in IMPERVIOUS 35% 2769 SO. FT. 0 C SOD 5,101 SO. FT. kj OFF LOT CALCULATIONS 0 RIGHT OF WAY - 337 SO. FT. apt DRIVE 7. . FT 0 PUBLICAPRON = 67 SO S/W - 202 SO. FT.. Oct- ' 0 TOTALS p SOD = 68 SO. FT..01", 0 AREA = 8.207 SO. FT. CP cA ZRY i z DRIVEWAY = 434 SQ. FT. 21.3 1 5.9 SIDEWALK = 230 SO. FT. SOD — 5,169 SO. Ff. 6 8 8" Iz I 1 A IF 16 96' 1 98.56' � Y 1 N89'59'20'W 115.52' PIA PREPARED FOR: (REFERENCE BEARING) D-R-HOWIN' STELLA VAST DRIVE ouiN7ef TRACT*G* 60' WIDE PRIVATE RIGHT OF WAY BUILDING SETBACKS FRONT- 20' REAR: 15! SIDE- 5' (50- LOTS) 7.W (55' & 60' WIDTH LOTS) SIDE STREET-. 15' NOTES: LEGEND: 1. ELEVATIONS SHOWN ARE PER LOT GRADING PLANS PROVIDED BY THE CLIENT.2. ELEVATIONS ARE BASED ON NAVD 1988 BUILDING SETBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVATURE DATUM. CENTERUNE PT POINT OF TANGENCY 3. FOR ALL LOTS MERE SIDE—YARD RIGHT OF WAY LINE RIP RADIUS POINT PRO POINT OF REVERSE CURVATURE SETBACKS ARE LESS THAN 7.50 FEET, AXX PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE MINIMUM 5.00 FOOT WIDE DRAINAGE AND s TYP TYPICAL ACCESS EASEMENT IS REQUIRED PER PASCO ===> PROPOSED DRAINAGE FLOW CS CONCRETE SLAB COUNTY LAND DEVELOPMENT CODE. (P) P CERAL PLAT = (C)CONCRETE CULATED THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/C AIR CONDITIONER PGS PAGES THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND S/w SIDEWALK SO. FT. SQUARE FEET F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK F1.R.M. FLOOD INSURANCE RATE MAP LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT NANG NORTH AMERICAN VERTICAL DATUM AND IS FOR INFORMATIONAL PURPOSES ONLY. NGVD NATIONAL GEODETIC VERTICAL DATUM D&UE DRAINAGE do UTILITY EASEMENT THIS IS NOT A SURVEY PDE PRIVATE DRAINAGE EASEMENT PUE PUBLIC UTILITY EASEMENT THIS IS A PLOT PLAN ONLY D&AE DRAINAGE&ACCESS EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED-THE F.I.R.M.MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 28,2014,AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS. RIGHT APPEARS TO UE IN ZONE*X',AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2111 ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.F.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS:BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF STELLA 3. NOT VALID WITHOUT THE AUTHENTIC A5M ELECTRONIC SIGNATURE AND THE AUTHENTIC VAST DRIVE BEING 1,111959"20"K PER PLAT. ELECTRONIC SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. (FIELD DATE:) REVISED: jj M I—=F:;?,' I C,�h^4 U F:;,'\/FE"Y I INI CD, Digitally signed by Is—W Boleman SCALE: 1" —30 FEET 4& MAPPING INC. -AMERICANIF51URVEYNG 8, APPROVED BY: MAPP11,16,11,1r--jannesw CER71FICATION OF AUTHORIZATION NUMBER LB#6393 "—=,n,,.,.,,......al.—VE 3191 MAGUIRE BOULEVARD. SUITE 2DO b. 18082CI LOT 27. tail 2020.06.0916:01,01-04 DO JOB NO. BLOCK 18 ORLANDO, FLORIDA 32803 Da FIRM (407)426-7979 DRAWN BY. DSB PLOT�P D6/04/2020 JG WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 [ I Q� Single Family Dwelling Plan Review. Comments 1. F.F.E..shall be a minimum of 8" above the road elevation-and an engineered site plan. 2: Lots shall be graded;to.comply with R401-3 of the F.B.C.- 3.. . Compaction test required if 24"or more.of fill:dirt is brought in at any one place. 4: Tie in survey, required:before.pouring concrete: 5. Driveways require.a R.O:W use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6: All setbacks shall be met. i. All property markers shall be uncovered and marked at time:of first inspection. 8: All A.D.A. requirements shall-be met: 9; No electric,.plumbing; mechanical;or framing shall be:covered without an inspection and approval first: 10.. All Garages shall comply with section:R302'.6 of the F.B.C. (Fire Separation). 11. Appliances.shall not be installed in a location.where subject to=mechanical damage unless protected by.approved barriers. M303:4 of the F:B.0 12. Water heaters.shall comply with section P607.3 ofthe F.B.C: 13:Foundation supports for A/C units.shall be raised at least 3" above finished grade-. M1308.:1.. - 14. Return air in all bedrooms. RB:C.. M1620,4 15. Smoke.detectors are to be installed in accordance with R3-13-.1 of the F.B.C. = 16.All glazing requirements are to be an accordance.with R308.4 o£the F.B.C: I T.All means.of egress are to be in accordance with RM I of the F.B.C. 18: "Green:gypsum board"shall not be used as:a backer-in showers or tubs. R702..4.2 F.B.C. . 19: Combination-type AFCI-breakers are required at all locations requiring-an AFCI type breaker. '20. Carbon monokide-alarms will be required in- new construction that.uses fossil-buini.ng heating. or appliances or an attached garage. 'They shall be installed in accordance with the F.B.C: 2:1..All plumbing, mechanical, and electrical shall be separate from unit to unit: This includes all: . . -underground:plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.C' .24: In accordance with the Land Development Code,lots shall be sodded before final at.least 10. feet around the structure. 25: R403.5,3Hot water pipe insulation insulation for hot.water'pipe with'a minimum thermal resistance(R-value) of R-3 shall.be applied to the following: . Piping 3h inch (1.9.1 mm)and larger in:nominal diameter. Piping.serving more than one dwelling unit. Piping located outside the conditioned space.. Piping from the water heater to a distribution manifold, Piping.located under a floor slab. Buried in piping, Supply and return piping in recirculation systems other than demand recirculation systems. 25: Blower door'test shall be provided before C.O: 26.A copy ofthe eneryy cacls shall be with permit at all times. 27. Copy of final insulation report shall be provided with Permit before final 28. No fence,pool or screen enclosure .is issued with this permit F.F.E.-Finished Floor Elevation F.B.C--Florida Building Code 6th Edition R.O.W.-Right of Way A.D.A.=Americans with.Disabilities Act N.E.C.-National Electric Code (2016) CITY OF " " BUILDING ZEPHYRHILLSNOTICE DEPARTMENT OF ADDITION OR CORRECTION . • NOT REMOVE ADDRESS DATE PERMIT# 25 12_ :��216 THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. 1* C -f It is unlawfijI for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth or other material,until the proper inspector has had ample time to approve 780-0020 FOR RE-INSPECTION the installation. OFFICE HOURS 8:00 AM-4:30 PM MON.-FRI. INSPECTOR CITY OF " " BUILDING ZEPHYRHILLSNOTICE DEPARTMENT OF ADDITION OR CORRECTION. . • NOT REMOVE ADDRESS DATE PERMIT# THIS JOB HAS NOT BEEN COMPLETED.The following additions or corrections shall be made before the job will be accepted. r l It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL coyer or cause to be covered,any part of the work with flooring,lath,earth or other material,until the proper inspector has had ample time to approve 780-0020 FOR RE-INSPECTION the installation. OFFICE HOURS 8:00 AM-4:30 PM MON.-FRI. INSPECTOR CITY OF " " BUILDING ZEPHYRHILLSNOTICE DEPARTMENT OF ADDITION OR CORRECTION . • NOT REMOVE ADDRESS DATE PERMIT# THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. S i l�v'I Cl 6 P r ,I v 40/� It is unlawfal for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIO S ARE MAD CALL cover or cause to be covered,any part of the work with flooring,lath,earth.. or other material,until the proper inspector has had ample time to approve 780-0020 FO ION the installation. OFFICE HdURS 8:00 AM-4:30 PM MON.-FRI. INSPECTOR CITY OF / / / / BUILDING ZEPHYRHILLSN- OTICE DEPARTMENT OF ADDITION OR CORRECTION D • NOT - • ADDRESS DATE PERMIT,�, S - u o- THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. lhw - ck G / ao - It is unlav;ful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780_�02!j>A&INSP TION or other material,until the proper inspector has had ample time to approve the installatign. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR CITY OF " " BUILDING ZEPHYRHILLSNOTICE DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS; DATE PERMIT#� 35 zs Vg 5s THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. c l It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth or other material,until the proper inspector has had ample time to approve 780-0020 FOR RE-INSPECTION the installation. OFFICE HOURS 8:00 AM-4:30 PM MON.-FRI. INSPECTOR 1 WngiEINTRAUB Lneeriiig aiul 111speelicros, Inc.. ENGINEERING LETTER Date: October 13,2020 To: Kevin R. Gude, Superintendent;D.R.Horton—Tampa Division From: Uslia Ramachandran, P.E., Weintraub Engineering.and Inspections, Inc. Subject: Structural Framing Inspection Location: Pasco.County, Florida Community: Silverado Lot: 27/18 Address: 35525 Stella Vast Dr.,Zephyi'hills,Florida,33541 Permit#: BNR-000320-2020 Statement by Engineer: Please be advised.that the Structural Framing installation at the above noted address was 3,d Party inspected by.a representative of Weintraub Engineering and Inspections, Inc.,working under my direction on September 23, 2020 to verify compliance with the approved plans and the Sixth Edition (2017) Florida Building Code Residential. Our inspection of the Structural Framing installation revealed that the system was installed in compliance with the approved plans and the Sixth Edition(2017)Florida Building,Code Residential. Based upon the above, it is my professional opinion that to the best of my knowledge, information and belief the Structural Framing for the subject home is installed in compliance with the.ap�ioved plans and the Sixth Edition(2017)Florida Building Code,Residential. rK If you have any questions,please contact me. + N� Respectfully, __ - '. � ., • 4� Weintraub Engineering and)<nspection,Inc Y.. TTslia Ramachandran, P.E. FL PE License# 731?9 3868 Sun City Center Blvd. Phone: 813-633-8000 Sun City Center,FL 33573 Fax: . 8,13-464-8026 Tin WEINTRAUB — Engineering and inspections, Inc: ENGINEERING LETTER Date: October 30;2020 To:: Kevin Gude D.R. Horton;Tampa . City:of.Zephyrhills—Building Department From: - -Usha Ramachandran,.P.E.,Weintraub Inspections &Forensic,Inc. Subject:: Rough Mechanical,:Electricafand Plumbing Systems Location:: Zephyrhills, FL Community: . Silverado Address: 35525 Stella=Vast Drive Permit#: 13NR-000320-2020 Statement by Engineer: Please be.advised that the Rough Mechanical,:Electrical and Plumbing Systems installation in the above noted community, at the above noted Address was inspected by Weintraub Inspections'&Forensic,Inc. Inspector Jesse: Stuiso (BN 6792) on October 28, 2020 for compliance with the approved plans and the Sixth Edition (2017) Florida Building Code,Residential. Our inspection, by way of removal of insulation, of the Rough Mechanical;Electrical and Plumbing Systems, performed by a Florida State Licensed One and Two Family Dwelling Inspector, working under my supervision, revealed.that the system is in compliance with the approved plans and the Sixth-Edition (2017) Florida Building, Code,Residential. Based upon the above, it is my professional opinion, that to the best of my knowledge, information and belief,-the Rough Mechanical,;Electrical and Plumbing Systems for the subject home is installed in compliance.with the approved plans, the Sixtli:Edition (2017) Florida Building Code, Residential. . If you have any questions,.please contact me. • ,�If1110f11//��- Respectfully, ����� Q��AMAChq�i�i, Wehitr ub Engi�Oe g`,a IAt re , 13�,Inc. No 731.19 . "T: Usha Ramachat , P&TAiE•.pF 2J ZO .. FL PE License !%.. 19�`� 'X: S�` 3868 Sun City Center NA AL�N��!� Phone: 813-633-8000 If gloss Sun City Center,FL 33573 • Fax: 813464-8026