Loading...
HomeMy WebLinkAbout20-324 ►� ► City Of Zephyrhills PERMIT NUMBER- . r �=� 5335 Eighth Street - Zephyrhills, FL 33542 BNR-000324-2020 Phone: (813)780-0020 Issue Date: 08/06/2020 Fax: (813)780-0021 Permit Type: Building New (Residential) Property'Number Street Address " ; 32 25 210100 01800 0310 35534 Stella Vast Dr OwnerInformation " Permit Information' Contractor Information Name: D R HORTON INC Permit Type:Building New(Residential) Contractor: D R HORTON INC Class of Work:SFR Construct Address: 12602 Telecom Dr Building Valuation:$107,000.00 TAMPA,FL 33637 Electrical Valuation:$6,800.00 Phone: (s13)549-1968 Mechanical Valuation:$7,200.00 Plumbing Valuation:$4,800.00 / 1v Total Valuation:$125,800.00 i !" Total Fees:$14,609.69 1 Amount Paid:$14,609.69 1 Date Paid:8/6/2020 1:33:15PM Project Description CONSTRUCT SINGLE FAMILY 2,238 SQ FT Application Fees Address Fee $30.00 Building Permit Fee $565.00 Transportation Impact Fee-City $36.32 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 SIF 1 percent Fee $83.28 Electrical Plan Review Fee $37.00 Transportation Impact Fee $3,595.68 Plumbing Plan Review Fee $32.00 Public Safety Impact Fee-Fire $273.00 Mechanical Plan Review Fee $38.00 Mechanical Permit Fee $76.00 School Impact Fee $8,328.00 Park Impact Fee-Single Family/Townhome $769.56 Driveway Fee $45.00 Electrical Permit Fee $74.00 Plumbing Permit Fee $64.00 Building Plan Review Fee $282.50 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER li 1111 / - bill oil! BILLING CONTACT .DAVID GLIDE D R HORTON INC 12602 TELECOM DR TAMPA,FL 33637 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00000421 07/29/2020 07/29/2020 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-000324-2020 Address Fee $30.00 Building Permit Fee $565.00 Building Plan Review Fee $282.50 Driveway Fee $45.00 Electrical Permit Fee $74.00 Electrical Plan Review Fee $37.00 Mechanical Permit Fee $76.00 Mechanical Plan Review Fee $38.00 Park Impact Fee-Single Familyrrownhome $769.56 Plumbing Permit Fee $64.00 Plumbing Plan Review Fee $32.00 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Fire $273.00 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 SIF 1 percent Fee $83.28 Transportation Impact Fee $3,595.68 Transportation Impact Fee-City $36.32 35534 Stella Vast Dr Zephyrhills,FL 33541 SUB TOTAL $14,609.69 REMITTANCE INFORMATION TOTAL �� $14,609.69 City of Zephyrhills 5335 8th Street Zephyrhills,FL 33542 July 29,2020 5336 8th Street,Zephyrhitls,FL 33542 Page 1 of 1 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting [2isko eaudn QOZV.c V-kor m, coo I a a I I I A A ! A A a Owner's Name Owner Phone Number Owner's Address Z 33 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS ESS3 7-r-)-kX 6 LOT# 131 1 SUBDIVISION 2- 23 1-) 0 (S I lb b 0 t�,"s I PARCEL 1D#T (OBTAINED iFRO4 PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTRF7 ADD/ALT E::j SIGN DEMOLISH 2� INSTALL L_j REPAIR PROPOSED USE 0 SFR 0 COMM OTHER TYPE OF CONSTRUCTION /-I BLOCK FRAME STEEL WAm re siA ff-c- I ecl F-L a:Yn DESCRIPTION OF WORK e-k , BUILDING SIZE S. Q\JFOOTAGE (�nnsq4*EIGHT . . . . . . . . . . . . . . =BUILDING VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS I — I .9b,_7 FLOOD ZONE AREA =YES NO . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - - - - - - - - - - BUILDER COMPANY SIGNATURE REGISTERED Y1 N FEft CURRES I Y/N Address (007— ILI t WIN, 54 111 Libense# 10-co ELECTRICIAN COMPANY S+r-n ArA Eledv- :t SIGNATURE REGISTERED I Y I N7 liff c CORREN _/N OZOZ/I,Zia:�,%aujj dq A to W Vq IUIW,) :jj g A UOISS11111110c)AW Zell 0 00 W 'a 1) ow 9119401W padwels jo p9juud'pedA4 fu810N 10 9weN Is JO p is jo pajulid padf,4 IdBION 10 9w8N 'ON u01Ss1wwO3 0 'ON UOISSIWWOD oilqnd fueloN oilqnd A.181ON' .uoIje0ljIju0pI se uoljaol quepl se peonpoid 8A8q/S8q JO aw ol umou%Alleuosied aje/s!oqM P22ROJd GABLI/SL4 JO aw-01 umou5f Tjfe-uosjaa 8173/sl 04M Aq a-V sIL4 ew ejojeq(powiii4e jo)ol ujoms pue peqljosqnS siql O q(p Oo;drL Aq ujoms pus peqposqnS �1013VNINOO r NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may basubject to"deed"restrictions" which may be more restrictive than County regulations, The undersigned assumes responsibility for cump\anoe with any applicable deed restrictions. ' UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired aoonbmctor or contractors to undertake work, they may be required to be ||oanoed in accordance with state and local regulations. If the contractor is not licensed as,required by |ovv, both the owner and contractor n��' be cited for o misdemeanor violation under state |ovv, If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing.Section at 727-847- 8009. Fuhbennona, if the owner has hired a contractor orcontractors, he is advised to have the contraotnr/e\ sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he \s not propedy]\oensed and is not entitled ho permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Rbcourse Recovery Fees may apply to the construction of newbuildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance nunnber89-U7 and 90-07' as amended. The undersigned also undersbsnde, that such fees, as may be due, will be identified at the time Of permitting. It is further understood that Transportation Impact Feea*and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. if the project doesnot \nvolvoamarbfoeteofocoupanoyor final power.release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior toperrn\t issuance in accordance vvithapplicable Pasco County ordinances. CONSTRUCTION LIEN LAW([�hapte�713. Florida Statutes, osamoended): |f valuation of work ia02.5O0.OUor more, | certify that |, the app|\cant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", | certify that | have obtained a copy of the above described document and pronn|aa in good faith to deliver itto the"Ovvner" prior tocorDnnahcg0eOt CQNTR&CTOWS/CWNER'S AFFIDAVIT: i certify that all the information in this application is accurate and that all work will be done in compliance with all applicable |avva regulating oonstrucUon, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all |8vvs regulating construction, County and City codes, zoning regulations, and land development-regulations in the jurisdiction. | also certify Uhat | understand that the reQu|ot(nno of other government agencies may apply to the intended work, and that it is nlyraapono\bUitvto identify what actions | must take tobeincompliance. Such agencies include but are not limited to: ' Department ofEnvironmental Protection-Cypress Boyhaade, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida VVate� Management District-Wells', Cypress Bayheado' Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks. Navigable Waterways. - Department of Health & Rehabilitative Servivae/Envinonmental Health Unit4WaUa, VVoatevvoter Tracdnnant. Septic Tanks. ' U8 Environmental Protection Agency-Asbestos abatement. - Federal Aviation/\uthority-RUnvvgys. ) UDdarntandUledthefoUovvOgnast[icUnOa-app|ytotheuseof fill: ' Use of fill is not allowed in rlo' od Zone"V' unless expressly permitted. ' If the fill rhabeda\ is to bb used in Flood Zone '7Y'. it is understood that a drainage plan addressing o '"connpeOoatiOg vok|rDe" Will be submitted at time of permitting which is prepared by n professional engineer \iooDood by the State of Florida. - If the fiU*[Dater{a\ is to be used in Flood Zone "N' in connection with o permitted building using otarn vvaU construction, | certify that fill will be used only tofill the area within the stem wall. - If DU rnotaho| is to be used in any area, i certify that use of such fill will not 'adversely affect acUomont properties, If use of fill is found to adversely affect 'adjacent properties. the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan iorequired. If | am the AGENT FOR THE OWNER. | promise in good faith to inform the c*vnar of the permitting conditions set forth in this affidavit prior to commencing construction. ( understand that separate permit may be required for electrical vvnrk` p|nmbinQ, signs, vvo||S, poo|o, air conditioning, gaa, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, no'r shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid un|ooa the work authorized by such permit is commenced VV%hiO six months of permit \GsUaDCe. Or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in vvdtng, from the Building {}ffido| for a period not to exceed ninety (QU) days and will dennoDatnaba justifiable cnu'se for the extension. If Work ceases for ninety(90) consecutive days, the job is considered abandoned. . WARNING TO OWNER- YOUR FAILURE TO RECORD ANOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. PASCO COUNTY, FLORIDA Permit No. 9Z F Date Permitted -Builder Name/Owner Name � ��� Control# i County Parcel No. 32-2-5 2-1-0/00,,((-��- 6j Mop-b3�a SubDiv: �' ,t,A a� Address/Location 0�-s—a V`_1 CC(- F Classificationrrype of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z` Z 36 Exempt ❑Yes ❑ No How Determined Impact Fee Amount $. .3, 6 3_.. Qb Zone No. TAZ: € SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ ' (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 7K !• IT- Exempt ❑Yes ❑ No How Determined, LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total -- Exempt ❑Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By y Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not-imply acceptance of concurrence,but simply receipt ofa copy of this.form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY D Q, Single Family Dwelling Plan Review Comments J. F.F.E..shall.be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to.comply with R401:3 of the F.-B.C. 3: Compaction test required if 24"or more of fill.dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5-. .Driveways require.a R.O:W. use permit. All 4 sides of drivewaythru the sidewalk shall have- expansion material. 6. All setbacks shall be met. 7: All property markers s1ia11 be uncovered and marked at time:of fir st'inspection. 8: All A.D.A.requirements §Ball be met: 9-. No electric,.plumbing;mechanical,or framing shall be:covered without an inspection and approval first. 10.. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).: . . 11. Appliances shall notbe installed in a-location where subject to_mechanical damage unless protected by approved barriers. M303:4 of the FAC 12. Water heaters shall comply with section 1?607.3 of the F.B.C: 13.Foundation supports for A/C units shall.be-raised at least 3" above finished grade. M1308.1 . 14..Return air in all bedrooms. F.B.C. M1620.4 15. Smoke-detectors are to be installed in accordance with.R313.1 of the F.B.C. 16:All glazing requirements are to be iri accordance with R308A of the F.B.C: 17. All means of egress are to:be'in accordance with R311 of the F.B.C. 18.-`-`Green-gypsum board" shall not be used as a backer in showers or tubs.R702.4.2 F.B.C. 19. Combination type AFCI breakers are.required at all.locations requiring an AFCI type breaker. 20. Carbon monokide alarms will be required in new constrdction that uses fossil-burning heating-. . or appliances or an attached garage. They shall.be installed in accordance with the F.B.C: 2.1. All plumbing,inechanical, and electrical shall be separate from unit to unit: This includes all underground plumbing and electric. 22. All 2016 ME.C. Codes will be enforced. 23. Tamper- Resistant-Receptacles in aecordarice with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 feet around the structure. .25. R403.5.Mot Water.pipe.insulation insulation for hot water pipe with a minimum thermal resistance (R-value) of.R-3 shall be applied to the following: Piping 31, inch (19.1 mm) and larger in.nominal diameter., Piping serving more than:one dwelling unit: Piping located outside the conditioned space.. Piping from the waterlieater to a distribution manifold. piping located under.a floor slab. Buried in piping, Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower-door test shall be provided before CO.: 26.A copy of the energy eacls shall be with permit at all times 27. Com of final'insulation ieo6it shall be provided ivith permit before LnaL r 28.-No fence, pool or'screen enclosure :is issued with:thisyermin F.F.E.-Finished Floor Elevation F.B.C-.Florida Building Code 6a'Edition R.O:W-Right of Way: A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) IN.STR#2020105246OR BK10129 PG3047 Page 1 of 1 07/01/2020 04:00 PM Rcpt 2177780 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles, Esq.,Pasco County Clerk&Comptroller I Permit No. Parcel ID No on oo-w(boo. -()3Ao NOTICE OF COMMENCEMENT state of Florida. County of PaSCO THE UNDERSIGNED hereby gives notice that improvement will be made to certain razi property,and in accordance with Chapter 713,Florida Statutes, the following information Is provided In this Notice of Commencement 1 Description*of Property- Parcel JdantificalJonrr No. �-C) (b1bC>% ks -1p- Xk-w--r0A0 P1n0--6'- �1Vn r L StrestAddress: �)!51G 22%A Il n k 2. General Description of Improvement New Single-Family Residence . 3. Owner frftrmdon or Lessee information if the Lessee contracted for the improvement Q.R. Horton. Inc . Name 12f;07T8lPcnnn nrivp Tamo;a 33637 -;:1 Address city state InterestinProportf. Fee Simple Name of Fee Simple Titleholder. (if different from Owner'llsted above) Address city State 4. Contractor. -D-R,.-Hortoj3- Inc Name 12602 Telecom Ddye Temps 33637 FL Address city state Contractor's Telephone No.: S. surety. NIA Name Address CRY state Amount of Bond: N/A Telephone No.: S. Lender. NIA Name Address city state Lender's Telephone No., 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)C7),Florida Statutes: David Gude Name 12502 Telecom Drive Tampa 33637 FL Address city State Telephone N urn bar of Designated Person: 813-740-97-20 8. In addition to hIms elf,the owner designates NIA of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b)',Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date Is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA-STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing too f commencement and that the fads stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO T2'%ture 61 Owner or Lessee,or Owner's or Lessee's Authorized OffleerlDirector/Partner/Manager 6gsistant SecrfifiarJ/D.R. Horton-Inc Signatory's Tffie/Offlce 20LE t,The foregoing Instrument was acknowledged before me this—Lday&Ams�. . �by . (D as Assistant Secretary (type of authority,e.g.,officer,trustee may In fact)for D.R.. Horton, Inc {name of party n be elf f om ins m ntvvas executed). Personally Known R OR Produced Idangfication Ij Notary Signature Type of Identffication Produced Name(Print) eP% Notary Public S- tM of Flod a Michelle Mayes My commission GG 067321 or 6/xp 1�1 1�57 1 Ij wpdatarocstnoUc=mmencemenLpcOS3048 PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 31, BLOCK 18, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A AND 11B AS RECORDED IN PLAT BOOK 77, PAGE(S) 79-86, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table Curvet Length Radius Delta Chard Bearing Chord Of 31.87 55.011 3311*51* S7324s45'E 31.42! P1 (REFERENCE BEARING) N891SW20*W 115.52' --1 C2 70.22'1160.00'1 25-08`43' S7O'2VSI-E 9.07r —9 45 Y E rT WU0 Una Table t: ON LOT CALCULATIONS Una III Direction I Length STELLA VAST DRIVE LOT = 9.851 SO. FT. TRACT "G" LIVING AREA = 1,672 SO. FT. U N89-59WE119.07- Rp 60' WIDE PRIVATE RIGHT OF WAY GARAGE - 432 SO. FT. ENTRY = 38 SO. FT. LANAI = 96 SO. FT. zi PATIO = 0 SQ. FT. DRIVEWAY = 331 SO. FT. I A/C PAD - 12 SO. FT. WALKWAY = 28 SO. FL IMPERVIOUS = 26% - 2609 SO. FT. SOD = 7,242 SO. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 409 SO. FT. DRIVE APRON = 57 SQ. Fr. PUBLIC S/W = 247 SO. FT. I SOD = 105 SO. FT z TOTALS I AREA = 10.260 SO. FT. 0 1;a 3V GR ALE DRIVEWAY = 388 SO. FT. 6 SIDEWALK = 275 SO. FT. fuk 15 30 SOD = 7,347 SO. FT. 21.3. mi 100 CO 12.6' -C-4 00 LOT 32 BLOCK 18 w 0 A/C p LOT 31 0 0 BLOCK 18 V) 9,851 So FT* III TYPAGE E A/9 PREPARED FOR: IN' D 0 p% BUILDING SETBACKS j N89'59'2 "W FRONT. 20' 48.61 LOT 33 REAR: 15' SIDE' V (50' LOTS) BLOCK 18 7.5' (55' & 60- WIDTH LOTS) SIDE STREET. 15' NOTES: 1. ELEVATIONS SHOWN ARE PER LOT GRADING LEGEND: PLANS PROVIDED BY THE CLIENT. 2. ELEVATIONS ARE BASED ON NAVD 1988 BUILDING SETBACK LINE PI POINT OF INTERSECTION DATUM. PC POINT OF CURVATURE CENTERLINE PT POINT OF TANGENCY 3. FOR ALL LOTS WERE SIDE-YARD RIGHT OF WAY LINE RP RADIUS POINT SETBACKS ARE LESS THAN 7.50 FEET, A PRO POINT OF REVERSE CURVATURE PCC POINT OF COMPOUND CURVATURE PROPOSED ELEVATION MINIMUM 5.00 FOOT WIDE DRAINAGE AND TYP TYPICAL ACCESS EASEMENT IS REQUIRED PER PASCO PROPOSED DRAINAGE FLOW CS CONCRETE SLA13 COUNTY LAND DEVELOPMENT CODE. (P) PER PLAT (C) THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE CALCULATED PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/C AIR CONDITIONER PS PGS PAGES BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND S/w SIDEWALK SQ. FT. SQUARE FEET OPTION UST FOR CONSTRUCTION. ALL BUILDING SET BACK REM.A. FEDERAL EMERGENCY MANAGEMENT AGENCY LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.I.RX FLOOD INSURANCE RATE MAP AND IS FOR INFORMATIONAL PURPOSES ONLY. NGVD NATIONAL GEODE NAVD NORTH AMERICAN VERTICAL DATUM nC VERTICAL DATUM & THIS IS NOT A SURVEY POED&AE PRIVDRAINAGEATE DRAINAGEACCESS EASEMENTEASEMENT PU PBLIC EASEMENT THIS IS A PLOT PLAN ONLY PLEE PRUIVATEUTILITY LANDSCAPE EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO2861", 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 28,2014,AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO UE IN ZONE'X", AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0 2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS:BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF STELLA 3. NOT VALID WITHOUT THE AUTHENTIC A5M ELECTRONIC SIGNATURE AND THE AUTHENTIC VAST DRIVE BEING N89`59`20"K PER PLAT. ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A M F=- FR I CD A,, r-,] SURVEYOR AND MAPPER. (FIELD DATE:) SU R \/F=- "r I N G Digitally signed byJarnes W Bole— DN—U5,st-Ftofid4t=0rlandm 30 FEET SCALE: -AMERICAN SURVEYING&MAPPINr� <�kM APPING INC. URMI INC.—lames niPas—poiatexons FOR APPROVED BY: ER LB#6393 emill�ibolessev"I CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 ' 180820 LOT 31. 3191 MAGUIRE BOULEVARD, SUITE 200 Date 2020.06.12 08:31. -000 THE JOB NO. BLOCK 16 ORLANDO.)FLORIDA 32803 FIRM (407 426-7979 st DRAWN BY. D.S13 PLOT PLAN 06-08-2020 JSO WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE