Loading...
HomeMy WebLinkAbout20-344 m City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BAR-000344-2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 07/16/2020 Permit Type: Add/Alter (Residential) Property. Number Street Address 02 26 210160 00200 0140 6219 9Th St Owner Information Permit Information . Contractor Information Name: CHRISTOPHER&CYNTHIA DOMSf Permit Type:Add/Alter(Residential) Contractor: THE WINDOW DEPOT LLC Class of Work:Add/Alter Residential Address: 6219 9Th St Building Valuation:$6,394.00 � ZEPHYRHILLS 33542 Electrical Valuation:$0.00 1/� Phone: (813)435-0828 Mechanical Valuation:$0.00 Plumbing Valuation:$0.00 Total Valuation:$6,394.00 // 1 Total Fees:$107.95 I Amount Paid:$107.95 Date Paid:7/16/2020 2:02:01PM Project Description REPLACE 10 WINDOWS S/S Application Fees Building Permit Fee $71.97 Building Plan Review Fee $35.98 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. J46c/ 1%1a4V4--'At9r' CONT CTOR SIGNATURE PE IT OFFICE PERMIT XPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Pr 813-780-0020 City of Zephyrhilis Permit Application Fax-813-780-0021 Building Department Date Received I r a Phone Contact for Permitting owner`s•Narne. t 4_1 v/S lam ' Owner Phone;Number. Owner's?Address ?S Owner_Phone Number' Fee Simple Titleholder Name` Owner phone'',Number' Fee Simple Titleholder Address �,q JAB ADDRESS I O! ' " LOT# SUBDIVISION PARCELID# (OBTAINED FROM PROPERTY TAX NOTICE) WORKPROPOSED NEW.CONSTR - -ADD/ALT SIGN [� [� DEMOLISH e• INSTALL e .REPAIR,, PROPOSED USE Q SFR' 0 COMM" OTHER TYPE OF`CONSTRUCTION 0 ',BLock Q: FRAME, Q STEEL - Q DESCRIPTION OF WORK 1&&_Vn4aIccet 0 //1 &ks d exoe S!Z'7° BUILDING SIZE . _ SO FOOTAGE= HEIGHT 7BUILDING $ VALUATION OF TOTAL CONSTRUCTION. =ELECTRICAL $ �D AMR SERVICE Q,_ PROGRESS.ENERGY Q. , W.R:E.C. =PLUMBING $ �J �� `°'' 1O0 Q VALUATION OF MECHANICAL INSTALLATION MECHANICAL —� 0 =GAS Q ROOFING Q SPECIALTY,,] OTHER FINISHED FLOOR-ELEVATIONS FL'OODZ-ONErAREA =YE$'_7+ NO=L-=',- Ai j�� j�� J—..t>Yytu' i:'ic`tr✓Y:��•`:'{ins BUILDER COMPANY SIGNATURE REGISTERED. Y./..N., 3,:% FE nse Address ((/ �/U Lice :# .. '4.L:.'1 iliRi: - ELECTRICIAN ,COMPANY., SIGNATURE REGISTERED Y/.N :, ,}FEE CURREA Y/N Address , - en se'# Y:•il,t. t. RLUMBER COMPANY SIGNATURE. REGISTERED Y 7-,X'-;'. 'FEE GURREN Address "License# MECHANICAL COMPANY SIGNATURE' REGISTERED" Y,4-' `' FEE-CURM Address :-License#; OTHER. COMPANY SIGNATURE REGISTERED. ..FEE CURREI% Address Ucensei# RESIDENTIAL Attach(2)',Plot:Rlans;,(2),sets:..gf,Building P,lans;,(1),set,,gf.Energy Forms;R-Q-W;Permit:for-new-construcUon, Minimum ten(10)working days'after'submittal date. Requlred''onsite;Coristriiction'Plans;Stannwater Plans vu/Silt Fence;iristalled, _ Sanitary Facilities&1 dumpster,Site Warts Permit for subdivislons/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Ufe.Sefety.Page;.(1)set of Energy Farms.R-O-W Permit for new construction. Minimum ten(10)working;days aftencwbmtttal-,,date.::Required onsite,Construction Plans;;Stormwater Plans.w/Silt Fence installed, Sanitary.Facilities&'1 dumpster:Site Work PermttJdr all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of°Engineered^Plans: ****PROPERTYiSURVEY:requtredJor,all.NEW construction. •Directions: ' Fill out application completely. Owner&"Contractor sign,back of application,notarized-- If over$2500,a Notice of commencement is required. (A/C upgrades over$7500) *' Agent(for the contractor)or Power of Attorney(for1he owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING- (copy of contract-required) Reroofs if shingles Sewers Sentice'Upgrades A/C, Fence (Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE'OF DEED RESTRICTIONS: The.undersigned understands that this permit maybe,subject to"deed"restrictions" which may.be more restrictive than'County-regulations. The undersigned assumes respohtiibilityfor compliance with any applicable deed-restrictions. UNLICENSED''CONTRACTORS AND "CONTRACTOR' RESPONSIBILITIES: "if the owner:has='hired_a contractor'or contractors to undertake work,.they may be-required Ito be licensed in accordance with;state.and,local regulations: If the contractor is not licensed as required by law, both the owner-and-contractor-may-be,cited for'a misdemeanor violation understate law.. If the owner or intendedy contractor-are uncertain as to�wheitrlicensing requirements.-mayapply.•forthe intended work, they are advised to,contact the Pasco County Building.Inspection,Division-Licensing Section at 727-847- 8009. .Furthermore, if.the owner has-hired a:contractor or.contractors, he is advised to have the-,contractor(s)•sign - portions of the "contractor-Block" of.this application for which..they.will.be:responsible: ,If.,you,.,as the owner sign.as the contractor, that may be an indication that he is not,properly licensed and'is.not entitled to permitting privileges.in.Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND.RESOURCE RECOVERY FEES:. The undersigned understands that.Transportation Impact,Fees-and Recourse-Recovery-Fees may�apply to the construction of-new-buildings; change of use in.existing buildings, or expansion of existing buildings, as.specified in Pasco County Ordinance number 89-07.and 90-07; as amended.. The undersignfied;also understands,that'suck"feas, as may be.due,.will be.identified;at the,time of. permitting. It is further understood taYTransportation Impact Fees and Resource Recovery Fees must be paid prior to receiving-a "certificate of occupancy" or final power release. .if the project does.:not involve a certificate of occupancy.or . final power release;the fees must be:paid-prior to permit issuance: Furthermore; 0 Pasco County'Water/Sewer Impact fees are due„they must be paid.prior-to.permit:issuance in accordance with applicable Pasco County;ordinances. CONSTRUCTION LIEN LAW--(Chapter 713;;Florida'Statutes,as..amended), Ifvaluation,,of work is$2.500.00,or-more,.I certify. that I,"—the—applicant,' have been�,provided-with-a-copy=of-the "Florida- Construction Lien` Law-Homeowner's Protection Guide" prepared by the Florida-Department of Agriculture',and Consumer Affairs. If the applicant1s_someone other than the"6wner",1 ceitify tf at:Rhave._obtained'a copy-of:.th6.&bove.described document and promise in,gooid faith to deliver it to the"owner"prior to commencement:,;.,..:,.,.. CONTRACTOR'S/,OVI(NERt AFFIDAVIT :�l certifacuthat,all,the informat on,.in this application-is,accurate-and.that all work will be done in compliance with all_gpplicable. laws regulating construction; zoning-and land.d'eveiopment. Application-is hereby.made to obtain-a. permit to do work,'~and- I nstallation.'as Find Gated': ,certify, that-no work.or installation'.has commenced-.-prior-to„issuance of.a permit.and theit-all work will.be,:pei formed to:meet standards of.all laws regulating a... -.•.ri ry �ion;'�Counry..:�and'City`codes;"zoning regulations; and land de'veto construdt pment' regulations 'in the jurisdiction: I.also certify that l.understand:that:"the regulations of other government:agancies may apply to-.the-intended work, and.that it is my.responsibility.to:identifywhat actions I musttake.to be in.,colmplianed.. Such.:agencies_include'bufare not.limited;toi; D'epartntenf:of..'Environmental Protection-Cypress:°Eayheatls, Wetland:Areas and Environmentally Sensitive •Lands,wVater/Wastewater,Treatment•.,. ,.., Southwest Florida Water Management District-lNells, . Cypress Bayheads, Wetland Areas, Altering Watercourses. Afmy Corps of`Engineers-Seawalls' a:oi;ks, Navigabi_iMaterways:- Department of Health & Rehabili_fative Services/Environmental,Health'-Unit-Vllells; Wastewater..Treatment., Septic.Tanks. tJSi; nvironrnentalProtection Agency=Asbestos:abatement. 'Federal Aviation.Authority-Runways." understand.that the following,restrictions.appIy to,#tq:use of fill: Use-of'fillis notalloWed in`Flood#Zon.eRV"unless expressly permitted. If-the-fill material'"-is to be used in Flood Zone "A', it is' understood that"a -drainage'plan addressing a "compensating1volume" will-be submitted at time of permitting which is prepared by-a..professional engineer licensed:bythe:State of Florida. If'-the fill:material:-is to.be ,used'in.Flood Zone "A in connection with a permitted building using stem'wall constructioni_l:eertify:thaffill wilt be used onlyto fill,the area.within:the stem wall. If fill material:is.to be .used in any area, I certify that use of such fill will not adversely affect-adjacent propert e's 1f use°:of-fill,,is.found,to..adversely affect:adjacent properties,,this owner may be cited.for violating the conditions-of:.the building permit issued.under the attached permit application, for lots,less than one (1). acre.:whichbare bibVeited.by,.;fill,an engineered drainage:plan is required. If I amu,tt`e:AC.EH 'FOR;TtiEl"01NNER,'I promise in goodfaith,to; nform.the;owner,;ofthe permitting,conditi_ons..setforth'in this:affid `pri6r.t0 co'rtfillencin'g�;construction. I.understand that a separate permit may be:required.for electrical work,. pIumt%ing'{signs;Fuvells;,;.pool$ airs-conditioning, gas;. or other'.installations=not specifically included im,thet.application. A� permit iss led'shall;be'cohstrUb.i to.tie a:license to,proceed with,the;work and not as authority to violate, cancel,,alter,;,or set aside&arty.provisions,nftle`fe'chrical'cddes, nor'shall'issuanceofa.permit prevent the Building official from.thereafter::.. �...s : requiring:a`-cb'rrection,of=:errorsxin:;plans;construction or violations of:any,codes :Every•permit issued;shall become invalid unless„thq.W_0tk aijthoFized bysucl .:=permit:.is commenced within six months of.permit.issuance, or if.work authorized-toy. the perrYtit is suspend"ed.or atifintlone&foe a period of-six,(6)months after;the`tlmittre work is,commenced.` n extension maybe.::requested,; in;•vi►riting;from;the;Building:.Offcial..for.a�perled:.not to exceed ninety (90),days.and will demonstrate justifiable cause for,tf'e'extensio'n;="#,work�.ceases:for ninety(90)jdansecutive days,the.job is considered abandoned. WARNING-TO:OWNER YOUR,FAII:URE T.O:.RECORD A.NOTICE-wOF.C.OMMENCE. NT.:MAY-RES.ULT'IN-YOUR PAYING:'rVVICE t=014`illUihR`O E1VIt=NTS'TO``YOUT APR( pER°F1r f'IFf1fOU IN 1=NC>�`y.6 �. :.AIN'FINANCING 'CON$UL-T WITH:YOUR LENDER;O't2`"AXM ATIi'ORIV Y BEFC�R jRECORIJING-61) NOT10Es0 MMENCEMENT: .. — FLORIDAJURAT'(F.S.'1_17.03)" ------ OWNER OR AGENT R,�4 Subscribed and sworn to(oraffirmed)before"me this S 's tied:and s o (o ad for me this- bY: �ud by, eyi Who is/are personally known to me or has/have produced Wh isd !ar a ally known to a or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commiss_ No. Name of Notary typed,printed or stamped Name of:Notary typed,printed or stamped Y e Q Plan Review Windows & Doors 1) :Need.manufacturing installation specifications: 2) Must.meet:sections 11308.and.R612 6fthe.2017 F.B.C. 3) If:windows are to be installed-inside the historical.district;.they will need to be approved by the.historical:committee:, 4:) No other work shall be.permitted (framing, plumbing;and.mechanical) unless-otherwise . . specified. 5:) This is for replacement:(glass for glass) only.. If you wish to change from screen or vinyl windows to glass,then additional information is required. .. 6:) All windows to wall connections:shall be left visible for:inspection. 7) All.labeling and stickers.shall.rernain..on windows until final.inspection: 8-). :No work shall start without permitfirst: THE WINDOW DEPOT LLC r- Certified General Contractor#CGC1504775 Licensed—Bonded—Insured 6201 Johns Rd Suite 4,Tampa FL 33634 4154 Corporate Ct,Palm Harbor FL 34683 Office—(813)901-5555 WINDOW/DOOR SALES CONTRACT The Window Depot LLC("Seller')agrees to furnish all materials and labor to complete the necessary improvement,located at the address listed below: Name: n A I�j �C(tiSLC' Phone: Yj'� LI Z S—l C)$I- S Address: Eh �� Email: q.11".I.CEv�- In accordance with the specifications given below: 1. Remove windows from 00 openings. Number of Entry Doors 2. Custom size and install _windows in opening. Manufacturer4 /-t" 3. Manufacturer C-L-U< Model q7/' Model 4. Style S-W&_5 11,dc, S�SL=0-r S 5. Color Number of Sliding Glass Door1 6. Glass packs A) f (so!v/ Manufacturers A 7. Screens Style ,n f S. Grids Options J�,A- 9. Locks A-tl-}-n 10. Tempered .n);, z Storm Protection 11. Obscure I 4r0- ✓J '­` Color Al 1 A 12. Workmanship warranty Style N 4A All projects will be Installed per code.Includes clean up and removal of all job-related debris. Additional CONTRACT SUM:$ Purchaser shall pay the C ntract Sum as follows: 7 riJ b3 1. Fifty Percent(50%)upon execution of this Contract($ 2. Forty Percent(40%)upon Installation($ ) 3. Ten Percent(10%)upon Completion of work($ 1 "Completion"of work means the date when construction Is sufficiently complete in accordance with the Contract Documents so that the Purchaser can utilize the work for its Intended use. 4. Amounts unpaid after thirty(30)calendar days shall bear interest at the rate of eighteen percent(18%)per year.Purchaser shall reimburse Seller for all costs incurred,including attorneys'fees,occasioned by Purchasers default under any terms of the Contract Documents. 6. Purchaser is obligated to pay the Contract Sum as described herein regardless of any financing terms in place. 6. Contract Documents.This Contract consists of this document,Change Orders,extra work/wood authorizations,If any,and all financing documents,if any.No promises other than those specifically set forth in the Contract Documents shall be recognized by either party.The entire understanding and agreement of the parties is contained in the Contract Documents. 1L s 7. Wort ascribed in the Contract Documents will commence in approximately V-' and be completed in approximately .The recited dates are approximations and are subject to scheduling difficulties of Seller,labor and/or material shortages,acts of God and other evens not foreseen by Seller. 8. Seller shall provide a lifetime warranty on its workmanship. This warranty does not apply to workmanship or materials not paid in full.Seller does not warrant any materials,equipment,fixtures,packaged products or specialty windows if the same comes with a manufacturer's warranty,rather,Purchaser shall rely solely on manufacturers'warranties.Seller's warranty excludes remedy for damage or defects caused by abuse,modifications not executed by Seller,vandalism,wind,natural disasters or perils,war,improper or insufficient maintenance,improper operation,or normal wear and tear.If Purchaser fails to notify Seller and give Seller an opportunity to make corrections,Purchaser waives its right to make a claim for breach of warranty.Liability under any warranty by Seller is limited to the replacement of the work or materials only and shall not apply to any alleged consequential or other claimed resulting damages flowing therefrom.THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES,EXPRESS OR IMPLIED,AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE,OR ANY OTHER END PURPOSE OR USE AND THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREIN. 9. Price Escalation-The Contact Sum is based upon material and labor costs in effect at the time of execution of this Contract.In the event that the process or completion of the Work is delayed by any act of the Purchaser which is not the fault of Seller,or by a force majeure event,to the extent that the cost of material or labor or both are increased beyond those upon which this Contract Sum is based,the amount of such increased costs shall be added to the Contract Sum. 10. Seller shall not be liable for any consequential,secondary,incidental,special,indirect or punitive damages of any kind,whether in contract,tort, Including negligence,warranty,or otherwise. 11. The parties agree that this Contract shall be governed by the laws of the Stale of Florida,and any action brought in thereon shall be brought in the State of Florida.Venue Is hereby agreed to be in Hillsborough County,Florida.The prevailing parry In any dispute between Seller and Purchaser arising out of or relating to the work shall be entitled to recover from the non-prevailing party all of its reasonable attorneys'and paralegals'fees,costs,including all costs not taxable as costs,In any litigation and any related appeals. 12. Both worker's compensation and public liability insurance are carried by the Seller and they are applicable to the work to be performed. 13. The undersigned warrant(s)that he is(they are)the owner(s)of the above-mentioned premises and the legal title thereto stands of record in his(their) name(s). 14. Contract price includes all coupons and/or discounts. 16. PURCHASER'S RIGHT TO CANCEL.This is a home solicitation sale,and if you do not want the goods or services,you may cancel this Contract by providing written notice to the Seller in person or mail.This notice must indicate that you do not want the goods or services and must be delivered or postmarked before midnight of the third business day after you sign this Contract. Receipt is hereby acknowledged by Purchaser,this day of ti 20 Approved and Accepted. Signature`of PurcFiasseerr qy� Signature of Purchaser By: 13520743v1 Officer: For: The Window Depot LLC Permit No. Parcel ID No 'J Z—7(— Z i —o)6o— &yiLdU NOTICE OF COMMENCEMENT State of_ I C r Lrul` County of THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement:. 1. Description of Property: Parcel Identification No._T�N SO& IS4— 4-9 D U/'!aQ C 22 "VAT Street Address: 7il fpp� } 2. General Description of Improvement_k=44, _4 I?_$QJ aJr.1d0.'�e i!J'f— ! 3. Owner Information or Lessee information If the Lessee contracted for the improvement: Name Address City State Interest in Property: Name of Fee Simple Titleholder. (If different from Owner listed above) Address Ne�Y l n `!��r�tA 1 1_C_ City State / 4. Contractor: 1 V 't !_ Address City + State Contractor's Telephone No.: 5. Surety: Name Address rNSTR# 2020089483--13K 10113PG 3622 Amount of Bond: $ 06/05/2020 11:43am Page 1 of 1 Rcpt: 2168654 Rec: 10.00 6. Lender: DS: 0.00 I T: 0.00 Name Nikki Alvarez-Sowles, Esq. Address Pasco County Clerk & Comptroller Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Name Address City State Telephone Number of Designated Person: 8. In addition to himself,the owner designates of_ to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement(the expiration dale may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different dale is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713,13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO re of Owner or Lessee,or Owner's or L ssee's uthorized Officer/Director rtner Manager Signaatorys re/Office (� ) The foregoing Instrument was acknowledged before me this Z�day of A �-.20�y_nw f''017 i1 pf) as (type of authority,e.g.,officer,trustee,attorney in fact)for C e (name of pa a behalf of inst merdw s executed). [IPersonally Known OR Produced Id�entificalicrA Notary Signature �! Type of Identification Produced Name(Print) �/7 Z`� , , CHARLES M FOSTER V'S'Notary Public-State of Florida =* *= Commissiop #GG 943176 My commission Expires 'nrrlr��` December 29, 2023 wp date/bes/nolicecommen cem ent_pc053O48 STATE OF FLORIDA,COUNTY OF PASCO rye THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT r ON FILE OR OF PUBLIC RECORD IN THIS OFFICE q �F WITNES ,MY HAND AND OFFICIAL SEAL THIS 43 DAY OF 2 0 20 Zt) � - ,.. NIKKI AL EZ-S W ES LERK&COMPTROLLER <c BY DEPUTY CLERK " 1 � . � a o • BaS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats Facts I Publications I contact Us I BCIS Site Map I Lints I Search F dda ,d' Product Approval C - USER:Public User Product Aooroval Menu>Product or.Apnlitatlon Search>flaolication List>Application Detail •- FL# FL17234-116 Application Type,, Revision Code Version 2017 Application Status., Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments:• Archived, + Product Manufacturer custom window SA L W RK SHALL COMPLY WITH PREVAILING Address/Phone/Email 1900 SW 44th Av . LORIDA BUILDING CODE, Ocala,FL 34474 RATIONAL ELECTRIC CODE, (352)368-6922 Af 097HE CITY OF ZEPHYRHILLS jlathrop@cws.cc ORDINANCES Authorized Signature • Jay Lathrop jlathrop"sxc Technical Representative Jay Lathrop , L0 6 2020 Address/Phone/Email 1900 SW 44th Ave Ocala,FL 34474 REVIEW DATE (352)368-6922 Ext 2l�ITY �� ZEPHy H jlathrop@cws.cc PLAN EXAMINER Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications,Inc. Validated By Steven M.Urich,PE cal Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Mndard Yeas AAMA/WDMA/CSA/10l/I.S.2/A440 2008 ASTM E1300 2004 Equivalence of Product Standards Certified By a'• Product Approval Method Method 1 Option A fro s If 1461 - I (lo-S I� Diu-sI� V ���'2vo�i a BAS01 i - 6910 6 P- FGROI 00wr lv�l o x� oil 1-7 _-_--.--------_.___. ynvm� _ - lip R BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us ! BCIS Site Map Links Search bProduct Approval 1 USER:Public User Ek�r:ar�+:virrn . Product Approval Menu>Product or Application Search>Angllcation Ust>Application Detail FL# FL17355-R4 n Application Type Revision Code Version 2017 Application Status Approved Comments Archived 77 ALL WORK SMALL COMPLY WITH PREVAILING Product Manufacturer Custom Window SygONGIFLORIDA EUiLDING CODE, Address/Phone/Email 1900 SW 44th AveWTIONAL ELECTRIC CODE, 'Ocala,FL 34474 THE CITY OF ZEPHYRHILLS (352)368-6922 jlathrop@cws.cc al IANCES Authorized Signature Jay Lathrop jlathrop@cws.cc REVIEW DATE Technical Representative Jay Lathrop CITY OF ZEg1 - Address/Phone/Email 1900 SW 44th Ave n�� EXAMINER Ocala,FL 34474 PLAN EXAMINER (352)368-6922 Ext 291 - '-- jlathrop@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Emall , 1900 SW 44th Ave. Ocala,FL 34474. (352)368-6922 Ext 291 jlathrop@cws.cc Category Windows Subcategory Horizontal Slider Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professlonal Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lucas Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 10/16/2021 Validated By Steven M.Urich,PE ' I Validation Checklist-Hardcopy Received Certificate of Independence EL17355 R4 COI EvalReport105%pdf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440-08 2008 ASTM E1300-04 2004 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 01/24/2019 Date Validated 02/07/2019 Date Pending FBC Approval 02/08/2019 Date Approved 04/16/2019 Summarlif of Products FL# Model,Number or Name Description 17355.1 HS-620 Vinyl Horizontal Slider XO HS-620 Vinyl Horizontal Slider,XO,Non-impact. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17355 R4 II CWS-1031A(HS-620,XO),pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner PE-58201 Impact Resistant: No Created by Independent Third Party: No Design Pressure:N/A Evaluation Reports Other:Max.sizes: 74",x 63"and 74"x 72".See installation FL17355 R4 AE Evallkeport1031A.p� details for,DPs.Glass complies with ASTM E1300-04. Created by Independent Third Party:Yes 17355.2 HS-620 Vinyl Horizontal Slider XOX HS-620 Vinyl Horizontal Slider,XOX,Non-impact. Limits of Use Installation Instructions Approved for use In HVHZ:No FL17355 R4 II CWS-1067(HS-620,XOX)apdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner PE-58201 Impact Resistant:No Created by Independent Third Party: No Design Pressure:N/A Evaluation Reports Other:M e 11�63f XOX 1/3-1/3-1 a - 355 4 E�EvalRe1/ a installation d DPs.Glass complies with ASTM Crea Third Party:Yes 1300-04. 17355.3 HS-620 Vinyl Horizontal Slider XX HS-620 Vinyl Horizontal Slider,XX,Non-Impact. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17355 R4 II CWS-1059(HS-620,L(X)pt�f, Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner PE-58201 Impact Resistant:No Created by Independent Third Party: No Design Pressure:N/A Evaluation Reports Other:Max.sizes: 74"x 63"and 74"x 72".See installation FL17355 R4 AE EvalReport1059.pdf detail for DPs.Glass complies to ASTM E3300-04. Created by Independent Third Party: Yes Bask Neat Contact Us::2601 Blair Stone Roa . a .h The State of Florida Is an AA/EEO employer.CopylIght 2007-2013 Stale of Florida.::Privacy Statement::Accesslbllity_Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: eGhxk Credit Card Safe GENERAL NOTES: HORIZONTAL SLIDER - NON-IMPACT 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED yyIV�SYSiEMS TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT 1900 SW 44TH AVE. EDITION. 00ALA,FLORIDA 34474 2.GLAZING OPTIONS:(SEE SHEET2) WWW.CWS.CC 751/4'FLANGE WIDTH - 3.CONFIGURATIONS:"W. 74•MAX UNIT WIDTH 620 PVC 36" 4.DESIGN PRESSURE RATING(SEE SHEET 2): [r7GLAS SASH WIDTH -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND HORIZ.SLIDER GLASS TABLES ASTM E-1300.04, NON-IMPACT 321/16• -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER S DLO INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300-04. ui 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.SEE SHEET 6 FOR ANCHOR p 7FLANGE a DETAILS. W INDLOAD DURATION FACTOR Cd-1.6 WAS USED FOR 6 HEIGHT WOOD ANCHOR CALCULATIONS. } _ m 7Lr c MAX C C 6 6.NOT APPROVED FOR IMPACT RESISTANCE.IMPACT PROTECTIVE Z UNIT p SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION. O HEIGHT 7.ALL FRAMES A 6 AND VENTS FULLY WELDED. Co X X zw 67 8.SERIES/MODEL DESIGNATION HS MAXX -620.SASH rL p ft HEIGHT 9.THE DESIGNATION XAND O STAND FOR THE FOLLOWING: X=OPERABLE SASH 64 1/16• to GLASS 751/4"FLANGE WIDTH 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR p 74'MAX UNIT WIDTH LOCATION. Z 36" - 11.EXTERNAL WEEP SLOT=5/16"x 2-1/8"LOCATED 4-1/2'FROM A MAX.SASH WIDTH BOTH ENDS. ,.'%v`NDREW 4le� 6 321116' �``�P�P�05NS.T!'Q,'o GLASS DLO A �Ct• No SB201 1p•••'y1� sa 1/a• —— — I Lucas A.Tumer E FLANGE 2015-04-27 1B 9O% STATE OF HEIGHT �� 21:05-04:00 .�1�' $"*.4 O R 1 MAX HEIGHT 591/16' X X I MAX SASH 4/27/2015 HEIGHT LUCAS A.TURNER,P.E. FL PE#58201 GLASS 1239 JABARA AVE. DLO NORTH PORT,FL 34288 PH.941-380-1574 A SHEET DESCRIPTION: GENERAL NOTES AND ELEVATIONS TABLE OF CONTENTS MAX. UNIT 2011 MTG.RAIL DRAWN BY: ATE: GENERAL NOTES&ELEVATIONS DESIGN PRESSURE RATING IMPACT RATING EMK 04/29J15 DP CHARTS&GLAZING DETAIL......2 SIZE REINF. ap SECTION VIEWS..................................3 74"x 63" NO SEE COMPARATIVE ANALYSIS CWS-1059 EXTRUSIONS&B.O.M..............:..........4 NONE ANCHOR SCHEDULE&NOTES..........5 74"x 72" YES CHARTS, SHEET 2 SCALE: SHEET INSTALLATION DETAIL.......................6.. 125 1 OF 6 FLANGE WINDOW DESIGN PRESSURES FOR EQUAL SPLIT"XW'WITH GLASS TYPES A.B,C,OR D umeffm Unh Unit Helght Width 351/2 391/2 43112 471/2 511/2 551/2 591/2 63 391/2 +50/-75 +50/-75 +501-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 1900 SW 44TH AVE. 431/2 +50/-75 +50/-75 +ED/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-72.6 OCALA,FLORIDA 34474 7/e'OVERALL 7/8"OVERALL WWW.CWS.CC 47 112 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-70.2 +50/-66.5 51 1/2 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-74 +501-67.5 +50/-62.1 1/8"ANNEALED 1/8•TEMPERED 551/2 +50/-75 +50/-75 +50/-75 +50/-75 +60/-75 +50/-71.3 +50!-65 +50/-60.4 9116"AIRSPACE 9116.AIRSPACE 620 PVC 591/2 +50/-75 +501-75 +50/-75 +50/-75 +50/-75 +50/-68.1 +50/-82 +50/57.5 118"ANNEALED 118'TEMPERED I"IORIZ"SLIDER 63 1/2 +50/-67.9 +50/-67.9 +50/-67.9 1 +501-67.9 +50/57.9 +50/-65.4 +50/-59.4 +50/55 67 1/2 +50/-60.1 +50/-60.1 +50! so.t +50! sD.1 +50/50.1 +50!-60.1 +So/.57.2 +50/-52.9 SIKAFLEx 552 OR SIICAFLEX 552 OR NON-IMPACT 71 1/2 +50/-53.6 +501-53.6 +50/-53.6 +50/-53.6 +50!.8 +50/-53.6 +50/-53.6 +50/-51 36 PURFECT GLAZE°H' 96 PURFECT GLAZE•H° 74 +50 -50.1 +50 -0 +50 -50 1 +50/-50 +50 50 1 +50 SO +50 -50 +50 50 FIN WINDOW DESIGN PRESSURES FOR EQUAL SPLIT"XUt"WITH GLASS TYPES A,B,C,OR D 5/8"GLASS BITE 5/8"GLASS BITE a Unit Unit Height Width 351/2 391/2 431/2 471/2 51 1/2 551/2 591/2 63 m 391/2 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-70.6 Z 431/2 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-70.1 +50/-65.4 O 471/2 +50/-75 +50/-75 +501-75 +50/-75 +50/-75 +50/-71.5 +50/-65.5 +50/-61 Ln 51 1/2 +50/-75 +50/-75 +50/-75 +50!-75 +50/-74.5 +50/ 67.5 +50/ 61.7 +50/57.4 ZO W 55112 +50/-75 +50/75 +50/-75 +50/-75 +50/-71 +50! 64 1 +50!58 5 +50/-54.4 F cc 591/2 +50/59.6 +50/-69.6 +50/59.6 +50/-69.6 +50/58 +50/-61.3 +50/-55.8 +50/-51.8 a 63 1/2 +50/-61.1 +50/51.1 +50!-61.1 +50/-61.1 +50/-61.1 +50/-5B.9 +50/-63.5 +49.5/-49.5 GLASS TYPE A GLASS TYPE B N 67 1/2 +50/-54.1 +50/54.1 +50/-54.1 +50/54.1 +50/54.1 +50/-54.1 +50/-51.5 +47.6/-47.6 u! 71 1/2 +48.2/-48.2 +48.2/-48.2 +48.2/-48.2 +48.2/-48.2 +48.2/-48.2 +48.2/-48.2 +48.2/-48.2 +45.9!-45.9 101 74 + .1 + +45 + -45 + + + OVERALL 7/8'OVERALL O 3/16°ANNEALED 3/161 TEMPERED Z FLANGE WINDOW WITH 2O11 MTO RAIL REINF.DESIGN PRESSURES FOR EQUAL SPLIT"X/X"WITH GLASS TYPES C OR D � � 7116'AIRSPACE 7/16'AIRSPACE ``��P�PNOREW 10, Unit Unit Height 3/16"ANNEALED 3/16'TEMPERED `� k� Width 35112 391/2 431/2 471/2 51 112 551/2 591/2 63112 671/2 72 36 SIKAFLEX 552 OR SIKAFLEX552OR 36 PURFECT GLAZE°H' PURFECT GLAZE ;' No 58201 391/2 +501-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50!-75 +50/-72.6 *; 431/2 +50/-75 +50/-75 +50/-75 +501-75 +50/-75 +50/-75 +50/-75 +501-75 +50/-723 +50/-67.0 - 471/2 +501-75 +50/-75 +50/-75 +5D/-75 +50/-75 +50/-75 +50/-75 +501-727 +50/-67.4 +50/-62.4 518°GLASS SITE 5/8°GLASS BITE 9 STATE OF 1• 51 1/2 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-74.2 +50/-68.3 +50/53.3 +50/58.5 +�0�•, p 55 QY P.' l/2 +50/-75 +50/-75 +50/-75 +50/-75 +5D/-75 +60/-75 +50/-70.4 +50/-64.7 +50/59.9 +50/-55.2 +��Q`S;•4 O R 1�.��N 591/2 +50/59.6 +50/-69.6 +50/-69.6 +50/-69.6 +50/-69.6 +50/-69.6 +50/-67.1 +50/-61.6 +50/-56.9 +50/-52.4 If ���iiSi .NAB 63 1/2 +50!-61.1 +50/-61.1 +50/-61.1 +50/-61.1 +50/-61.1 +50/-61.1 +50/51.1 +50/58.9 +50/54.3 +50/-50.0 67112 +50154.1 +50/54.1 +50/54.1 +50/-54.1 +50/-54.1 +50/-54.1 +50154.1 +50/54.1 +50/521 +47.9/-47.9 71 1/2 +48.2/-48.2+48.2/-48.2+48.2/-48.2+48.2/-48.2+48.2/ 481+48.2/48.2+48.2/-48.2+48.2/-0.2+48.2/-48.2 +46/-46.0 4/27/2015 74 +45.1/-45.1 +45/15 +45/-45 +45/-45 1 +45/-45 1 +45/-45 +45/-45 +45/-45 +45/-05 1 +45/-45 LUCAS A.TURNER,P.E. FL PE#58201 FIN WINDOW WITH 2O11 AATG RAIL REINF.DESIGN PRESSURES FOR EQUAL SPLIT"X/X"WITH GLASS TYPES C OR D 1239 JABARA AVE. Unit Unit Height NORTH PORT,FL$4288 Widthv 35 1/2 391/2 431/2 471/2 51 1/2 1 551/2 591/2 63 1/2 67 1/2 72 GLASS TYPE C GLASS TYPED PH.941-380-1574 SHEETDESCRIPTION: 39112 +5D/-75 +50/-75 +50/-75 +501-75 +50/-75 +50/-75 +50/-75 +50/-74.8 +50/-69.6 +50/-64.5 DESIGN PRESSURE 43 1/2 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-75 +601-74.9 +50/59.2 +50/54.3 +50/-59.6 CHARTS AND GLAZING 471/2 +50/-75 +501-75 +50/-75 +50/-76 +50/-75 +50/-75 +50/-70.0 +50/54.6 +50!59.9 +50/-55.4 DETAILS 51 1/2 +501-75 +50/-75 +50/-75 +50/-75 +50/-75 +50/-721 +50/-66.0 +50/-60.7 +50156.3 +50/-52.0 DRAWN BY: DATE: 55 1/2 +50/-71.1 +50/-71.1 +50/71.1 +50/-71.1 +50/-71.1 +50/-68.5 +50/52.5 +50/57.5 +50/53.2 +49.1/-49.1 EMK 04/22/15 59 1/2 +50/-61.9 +50/-61.9 +50/-61.9 +50/-61.9 +50/-61.9 +50/-61.9 +50/-59.6 +50/-54.7 +50/50.6 +46.6/-46.6 P; M+50/54.3 +50/54.3 +50/54.3 +50/-54.3 +50/-54.3 +50/-54.3 +50/-54.3 +50/524 +48.3/-48.3+44.4/-44. CWS-1059+48.1/-48.1+48.1/-8.1+48.1/-48.1+48.1/-48.1+48.1/-48.1+48.1/-48.1+48.1/-48.1+48.1/-48.1+46.3/-46.3+42-6/-42.6 NOTE: scALE: +428/-42.8+428/ 42 +42.8/-42 8+428/-42.8+42B/-428+42.8/-428+42.8/-428+42.8/-42B+42.87-42.8+40.9/-40.9 SHEET +40.1 -40.1 +40 -40 +40 -40 +40 -40 +40 -40 +40 AD +40 -40 +40 -40 +40 -40 +4p 4p IF SIZE INTENDED IS NOT SHOWN,USE NEXT LARGER SIZE. 1 1 2 OF 6 ckwo INTERIOR WINDOW 1900 SW 44TH AVE. w 1 18 11 3 2 13 3 11 18 OGALA,FLORIDA 34474 www.cws.cc 620 PVC HORIZ.SLIDER NON-IMPACT ni 0 30 m 1 VD 17 Z 4 9 i9 91 5 B 8 8 1 Z W sSECTION VIEW B-S aIx 0 U W a 3 38 39 p Z - INTERIOR - Pp10REtl"��sp�i -`fir f No 58201 34 �*•• * '*S 4 9 STATE0.0 3 "'1/0NAiuE 1 1 4/27/2015 SECTION VIEW LUCAS A.TURNER,P.E. MTG RAIL REINFORCEMENT{2012011}REQUIRED ON UNIT HEIGHTS ABOVE 63" FL PE#5820 1239 JABARA AVE. 1 NORTH PORT,FL 34288 PH.941-380-1574 ETDtEcRipTTu IpT 'SECTION VIEW A-A SECTION VIEWS DRAWN BY: DATE: ALTERNATE FIN FRAME EMK 04122/15 D N .. ITEMS NOT SHOWN FOR CLARITY: CWS-1059 - 7-8,10;12,15-16&21. 8° = SHEET 1:2' 30F6 PARTS LIST CORNER CONSTRUC7ION /�7( •�ITEM PART DESCRIPTION MATERIAL VENDOR 41/8• ViIINDOW SYSTEMS L�`-°/� CrslytklllL®��//1) � 1 H-6127 MAIN FRAME PVC ATN 1J 2 H-6135 SASH INTERLOCK RAIL,INT.PANEL PVC ATN 3 H 6139 SASH DRAW RAIL PVC ATN 1 1900 SW 44TH AVE. OCALA,4 H-6140 SASH TOPBTM RAIL PVC ATN 1 1/2• WWW. FLORIDA 34474 W W W.CWS.CC 5 H-6140 SASH INTERLOCK RAIL,EXT.PANEL PVC ATN 6 P-3028 SETTING BLOCK,1/8"x 7/8"x 2" FRANK LOWE 4 5 7 P-3029 SCREEN LIFT TABS STEEL SUMMIT 1l16" CORNER WELD 620 PVC 8 P-3033 SCREEN SPRINGS STEEL FLA SCREEN 47l6" 115/16" 1/1s° ALL SIDES I'IORIZ.SLIDER P-3218 SCREEN FRAME ALUM FLA SCREEN 0 1:8 10 P-3228 SCREEN SPLINE DAPA NON-IMPACT 11 P-3305 WTSP.,0.187"x 0.270"SOFT FIN AMESBURY I 12 P-3511 #8-18 x 0.625"PN PH TEK#2 POINTZP STEEL FASTENAL F—v 13 P-3783 IMPACT SASH LOCK INTERLOCK 14 P-3784 KEEPER INTERLOCK ~ 15 P-4146 #8-18 x 0.750"FH PH#2 POINT TEK ZP STEEL FASTENAL PVC MAIN FRAME-H-6127 PVC TOPBTM RAIL-H-6140 p 16 P-4754 SCREEN CORNER KEY NYLON FLA SCREEN 17 P-5420 WEEP COVER ASSY NYLON ASHLAND m n 18 P-5421 0.625"HOLE PLUG NYLON HEYCO c �+1 11/16 I+-- 19 P-5423 48-18 x 0.500°PN PH TEK 92 POINTZP STEEL FASTENAL 2 1/8" Z I I � 7/16" 20 P-5428 ROLLERASSY AMESBURY 0.50° 5/16° S2 23 P-5436 JAMB BUMPER RUBBER MINOR RUBBER 24 P-5441 L BLOCK NYLON 1/t6" 1/16' 1/76" O Q 26 S-2004 REINF,SIDE RAIL ALUM ASCEND 1 15/16" 1 15/16" 1 3/16" a 15/1+6• 33 a 27 S-2005 REINF.,MEETING RAIL,INT.PANEL ALUM ASCEND 2 D 3 cc 28 S-2029 INTERLOCK ADAPTOR ALUM ASCEND to 29 S-2030 ROLLER TRACK ALUM ASCEND in 30 S-2030 ANTI-LIFT FILLER ALUM ASCEND PVC INTERLOCK RAIL-H-6135 PVC DRAW RAIL-6139 ALUM INTERLOCK-S-2029 PVC GLAZING BEAD-S-6141 31 S-2043 REINF.,MEETING RAIL,EXT.PANEL ALUM KEYMARK z LUM 34 33 S-6141GLASS SEE"GLAZING BEATIO DRAIL PVC ASCEND ATN HEET2lit 1/76" 1 5116° 1 5/16" 4. J`,`�'P�OEEVV f TG'��'� 35 DOW CORNING 1199 SILICONE 5/16°—{ '�"o •�� SF 36 PURFECT GLAZE"H",SIKAFLEX552 SILICONE HENKEL/SIKA I Ste; No 58201 :73 37 S-2011 REINF.,EXTERNAL ALUM ASCEND 1 5li6" 31 11/16° 3 1 1/16° 1 1/16• =*: 38 P-3515 #8 x 5!8"PH FLAT WHITE SMS STEEL FASTENAL 1/16" :9Qt" STATE OF 1�4U 39 P-5400 COVER,EXT.REINF. PVC TEAM PLASTICS os3• LINE NP2 29EMS NOT USED: ALUM REINF.-S-2043 ALUM REINF.-S-2044 ALUM REINF.-S-2005 ALUM REINF.-S-2004 ''���iss'ONA4E ?,,, 5/8 19/16" 3/ 7/16' z T 39 4/27/2015 1/18"� 9 30 7/L 1I" 1116°' LUCAS A.TURNER,P.E. ]� FL PE#58201 PVC COVER-P-540D 1239 JABARA AVE. ALUM ROLLER TRACK-S-2030 ALUM EXT.REINF.-S-2011 NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: DRAWN BY: DATE: EMK 04/22/15 G A: CW S-1059 SCALE: SHEET NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 12 4 OF 6 Long DOW5 19DO SW 44TH AVE ANCHOR ATMIDSPAN 8'MAXO.C.(TYP.) OCALA,FLORIDA 34474 FOR UNIT HEIGHTS OVER 63'(TYP.) 3 4'MAX(TYP.) W W W.CWS.CC SEE NOTE 2 -I 3•THRU FRAME ANCHOR(TYP.) 6'MAX(TYP.) s•,(Tw.) a°MAX(TYP.) s°MAX ) 620 PVC SEE NOTE 2 HORIZ.SLIDER INSTALLATION 181/4" ANCHOR(TYP.) INSTALLATION NON-IMPACT MAXI O.C. ANCHOR(TYP.) (�L MAXM O.C. F X X X X m • rn z 0 S2 zW oCc a U' W C -ANCHOR LAYOUT-(FLANGE) ANCHOR LAYOUT-(FIN) O CD M NOTE THRU FRAME ANCHORS TG RAIL Z �:• No 56201 •'g� O. ¢: SRO STATE OF :��: NOTES: :���..F p,,.•��. 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.SILL ANCHOR SPACING SAME AS HEAD. ���s`S O...O..NG,`�� 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 114". USE SHIMS WHERE SPACE GREATER THAN 1/16'IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 4/27/2015 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. BE PROTECTED TO PREVENT REACTION. # A AVE.. 1239 JA BAR l 39 A .. S.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT, 34288 SPECIFIED IN TABLE 1,SHEET 6. PH.941-3BD-1574 SHEETDESCRIPTION: 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE-1 X BUCKS ARE OPTIONAL ANCHOR SCHEDULE AND NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3'FOR MASONRY,1'FOR WOOD AND METAL DRAWN BY: DATE: 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. EMK. 04/22/15 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWO s: . 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: CWS•1059 - FMA/AAMA 100(FIN WINDOWS),FMA/AAMA200(FLANGE WINDOWS), FMAIWDMA 250(BOX WINDOWS),FMA/AAMAIWDMA300(E)CTERIOR DOORS) SCALE:. SHEET 120 6OF6 MIN.EMBEDMENT SUBSTRATE' �® SEE TABLE 1 MOTHERS TYPICAL HEAD ANCHORAGE 1/4'MAX SHIM MIN.EDGE DIST. SUBSTRATE SEE TABLE 1 WINDOW SYSYEMS MIN.EDGE DIST. 1900 SW 44TH AVE. SEE TABLE 1 SEE TABLE 1 BY OTHERS 1/4"MAX SHIM SEE TABLE 1 OCALA FLORIDA 3474 WWW.CWS.CC SUBSTRATE BY OTHERS MIN.EDGE DIST. SEE TABLE 1 o SEE TABLE 1 MIN.EMBEDMENT INSTALLATION ANCHOR GZO PVC PERIMETER SEALANT SEE TABLE 1 SEE TABLE 1 BYINSTALLR HORIZ.SLIDER INSIDE AND OUT IN.EMBEDMENT SEALANT BEHIND (=] SEE TABLE 1 NON-IMPACT FLANGE BY INSTALLER 1/4"MAX SHIM 010000 TZ Qo PERIMETER SEALANT F BYINSTALLER Q BYINSPERIMTALL R��� INSIDEANDOUT INSIDE AND OUT INSTALLATION ANCHOR } SEALANT BEHIND JL014, SEE TABLE i m FLANGE BY INSTALLER SEALANT BEHIND CID INSTALLATION ANCHOR FIN BY INSTALLER ZO SEE TABLE 1 HORIZONTAL SECTION C HORIZONTAL SECTION 6 TYPICAL FIN ANCHORAGE N TYPICAL JAMB ANCHORAGE 6 HEAD AND SILL SIMILAR FOR FIN INSTALLATION ZO W 0 NOTE:ADDITIONAL THRU-FRAME ANCHORS a (AS SHOWN IN DET.A/6)REQ'D AT MTG RAIL, SEE SHEET 5 ANCHOR LAYOUT. w 0 CI I II Z SEALANT BEHIND 1/4'MAX SHIM ��i�p� FLANGE BY INSTALLER P��PS,ND..N S ;t PERIMETER SEALANT MIN.EMBEDMENT %41 JV; v `c•'•�1n% BY INSTALLER SEE TABLE 1 ti. : No 5B201 '�75 INSIDE AND OUT SUBSTRATE BY OTHERS MIN.EDGE DIST. STATE OF :'4+:0: SEE TABLE 1 SEE TABLE i SEALANT UNDER SCREW VERTICAL SECTION yA�SF�0 R t O P �Z � HEAD BY INSTALLER 6 TYPICAL SILL ANCHORAGE �Ziy/ONA„ ���` z� 4/27/2015 TABLE 1:APPROVED INSTALLATION FASTENERS LUCAS A.TURNER,P.E. FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. FL PE#58201 FLANGE CONCRETE(2.0 KSI MIN.) 3/16"ITW TAPCON 1" 1-1/8" PERIMETER SEALANT 1239 JABARA AVE. FLANGE HOLLOW OR GROUP FILLED CMU(117 PCF MIN.) 3/16"ITW TAPCON 1" 2" BY INSTALLER NORTH PORT,FL 34288 FLANGE CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" INSIDE AND OUT PH.941-380-1574 D HORIZON TAL SECTION FLANGE HOLLOW or GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4' 2-112" 8 BOX FRAME INSTALLATION SHEET EscRIPrION: 3116'ITW TAPCON SIMILAR FOR SILL AND JAMBS FOR BOX INSTALLATION FLANGE 2XMIN SOUTHERN PINE(G=0.55) OR ELCO ULTRACON 1-3/8° 7/8" INSTALLATION DETAILS FLANGE 2XMIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-318" 7/8" FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN BY: DATE: 16 GAUGE(0.060°)MIN.STEEL STUD #10.16 HILTI KWIK-FLEXOR ITW FULL THREAD UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: EMK 04/22/15 FLANGE (33 KSI YIELD M" TEKS SELF-DRILLING SCREW THRU 0.060" 7/16" MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED D x: 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. FLANGE 7/16° CWS 1059 - 1!8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" -PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS FIN 2XMIN.SOUTHERN PINE(G-0.55) #10 WOOD SCREW 1-1/2" 1/2" SHOWN FOR FLANGE WINDOWS. scALE .SHEET 1:2 60F6 J