Loading...
HomeMy WebLinkAbout20-353 i -��������� `. City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BGR-000363t2020 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 07/16/2020 Permit Type: Building General (Residential) Property Number Street Address 1126 21 0010 10100 0010 5533 9Th Street Owner Information Permit Information Contractor Information Name: BARBARA&DONALD FROST Permit Type:Building General(Residential) Contractor: TRIPLE CROWN ROOFING Class of Work:Reroof INC Address: 5533 9Th St Total Valuation:$11,550.00 ZEPHYRHILLS,FL 33542 Total Fees:$146.63 Phone: (813)788-9731 Amount Paid:$146.63 Date Paid:7/16/2020 10:16:24A n 7 V lW Project Description REROOF METAL Application Fees Building Permit Fee $97.75 Building Plan Review Fee $48.88 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. C RACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813.7M0020 City.of Zephyrhills Permit Application Fax-813.78aoo21 Building,DepartMent -. r ,:Phone:Contact,fo � - .'� -+•• r - :'ik•J ns 8:N•`me: :� 8f1-fl11 •;ownat'pioite' um tier:.: OaArrner'a ddress 3 ..: ":4' / ,� _ :-rya,t A S .3.. : k yes OuVner PlloribJ�litmbe'r`'` bwlitsrPhon®Nilirti®tr ; r;- <y _ , y Yt/N DI7 A!� 5 3 q- - _ - ox•:ili , Pa. I O ,tiUBDIVISiON .. 0.7" /4i h- PARCEL;ID#; - ._ bBTA1NEDRO 4ROPEftTll!tAXiNtil �)Rr' . ;.<. Wd� .PRGP•.`OSED:, f1VEW-CONSTdt• :�ADG%ALT.. ;SfGN'• _ EI�I S , INSTALL:. _ PROPOS D fiAa•' OTHER. -r,•:... _ '!!~ OCTYPE. P.+ONSfiRUT N MAME`;;•;-$' J; �E�CRIPTICN OP:.ti116f3K'.` ` . �Ca/ BUILDING•SIZE SQ:FOO AG ,, x� :rs .'•.:•-...'. r: 1• • BUILDING _ •. $°.,... .. `+ • �f UVALATION;OF�TOTAt '.C:O.NSTRU CTION ELECTRICAL..,, E. D.0::AIVIP'SERVICKE'EIERGY =PLUMBING =MECHANICAL $ VA ION OF.MECHANICAL,.iN�N =GAS ROOFING:-. ;�,;, ,,SPE_lIALTY,= OTHER;:._.. EINI$HED FLbOR ELEVATIONS •';i ::, ' BLOOEnXONE:'AREA ``" :' Y[=S"'';; NO .BUILDER COMPANY.: `•:r:.,.;:. •.,. ::.. ,.;>:�;...;.:.;:�. .,:.;:.. SIGNATURE 'FEEiGURRERr''r' /lc: €LNi iM a¢. ' ' Aildre'ss` Ucense#::c 71 -ELECTRICIAN COMP y ,:>• ,;:~ .,.:.... ::. SIIaNA;rIJRE :REGISTI$ D� Adtlress' ' PLUMBEit" 'SIGNATURE R�'Gtisir 2i i ^`:Y%-1V:' ?tfEE•CUQREt�'''r1: iala;/J�f ` Address;• - MECHANICAL. ' 'COMPANY-' :>: lNet4 SiGf� U • ':REGISj`ERED'' �z': r;r5;•.•'.::,a•. .Y/+�:N :Address,:­ :. ... , ... ,r. - .. •�t'� - ---- -- ucsrise;# OTHER,,.. + u. ' :N•�:; 1S1`ERE Y N':: FE CU E' RREP: ;',. Xz/,._ SIG AIU . .. RE� D`_ / L(cense,#''' `.;�✓;. ;,.J .;r,, c•t• .e`. -- :r' for>•' '.ri ;y r tr�� 0 R' 'r: W� e� 'n ''r+ y2 d- 'fC VIA'' r •��� teat of rS':;,•. orihis�: t q:��. ,t? •;. ;��, a'�s ti�'seta of�� t�dt ;;�I�ri'•...(1 e►g �R�r ,.r. �.. RSSIDE�IYIAL•' ��Atta�ch(�).fi otlil.'n.,, „;,.;1,. :�..;c.,s�r!�w'.:.• r:l."�"'',n, :"A I�;�' rNifi t ii r t`n' c0' o`'ikf+°�ifa'sef(er s tii i l ,ate' :fti re��an�sN -Ciins�tt odaii�P..l�irs;S rli it atefP ti3"v/Snt?l=pnc �tnsfaiis7 f. .) ! .;Y...,. SanitaryFecilldes`: :ftumpstr;a81Ce,Workenri�t for sub'ai,�rsrao?3n . prots.'. •Attach Z°com late;sets'o�,Buf(dtp9=Plaiistpf�isa�leife~$afe.• `PagB'(f)•`set°ofiEtrergy.:Fo'rms;A_O:W,Permit:forfiewccgl�5tructlon •:.,._ ;A' COMMERCIAL ,,.(..), P a Minimum tat(10),wgliingtlsiaft�er�s" titrtittalsre r.F�eaq' if�ed,;Qnslte Constfuct�orr�F;t�hsy�Stocrnwatbira�fejr:;+w/a�ilt�Peneenilelalled,',:: Sanitary'FaNtlffes&1'ifuijfsta�X'Site'lVork l�errirlt'for aIt riew projects:All oommerctal:raqutrements must riieet'compif8nce _... SIGN PERMIT Attach`(2)sets ofx�ngii ee •••*PitdPPR;,TY S�J �YEY►eQuti`ed foralf;NPW cofistruetion: ;..:: Directions: Fill.out applica Ion:completely. owh6it 8.: ,n, .ctor:tign;hacteofwap (Ic dgn�notarized 71 'If ever S2�d0:a NotiC®of Colnmencerttent.is requirets: (AIC upgra_'des over.$7500) •• Agent(for•.the,contractor.)orPower ofAttomey(fbr;the'ownar);woUld b.b.someotie:with notai,ttI lette hom bwner-ailtfi6riiing same:: -OVER:TF)E:000NTERsPERMITTING. (cgitofcoratra�t;;[equlred), .. Reroofslf Ingles Sewers Sanitce Upgradr?s A/C:'' 'FeriCcs'(PIoUSuivey/Footage) Drlveways=Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The-urid6f6igi ed=understands that•this permit-may be subject to"deed"restrictions" which•may_:be-more.:restrictiveL.than:County,gregulations. The undersignedpassumes-responsibilityfor�'complienco�wlt,any applicable deed.-restrictions; :lfR1 lCEMSED t3ONT f..`CTOR AM-4O'NTRAC�iiaR�R SPON811 lriT1ES N'f¢#lie'`oVtirie 11cli,Iilred"a contracfor or contractors to undertake vvork;;.lheyy�be,requiredtto be licensed in:accorfanc :wltl •:ptake,and..localEregutatibis °If'the °.'contractorts::n6t-'ilcensedtas requtired-by law, both the'ewneru'anii ce 'dited 10''a- istiemeanor violation under state'law: If the-owner?:or, intlanded:;contractor.are uncertain-as-to what licenS ng:r ulremenfs:irrial ly. r'the inien-dedY�rork;:they�re�dvised to contact the Pasco.=County°BuiI nlrinapr6ctlon�'DIVI91iin== icensing Section at727-847- 8009. -Furthermore, if the oWner l,ast;hireLd.a,contractor-or contractorsk:he•:is ad�tieed:>t4 have the contractor(s) sign portions:af.the "contractor'Block°.of1hii.appllcaticn for.which:they wllt;�e<responsible«,.lf you, as the.owner sign as the contractor, that may be ammfidlcationiheif he is not properly licensed-and is not entitled.4o-permitting-privileges in Pasco „County,;.: . . "T-RM-SPORTATION IMPACTIUTILITtES'1IMP- CT AND RESfi}URCE'1tiECOVERY'i:EES: The uncCersignedYuoderstatads that-Transportation Impi ct Fees:ab'd:Recourse Redov.erwy4F-ees:,,ayRappty to-the,,,c-onstr<uctiampUnew buildings;•harige of use iri°ezisting=buildirigs;of expansion':af`'eiift3ting'b'UAJdtngs, as speci kd`!n PascoCounty Ordinance-number A" and .90-07,,.as.emended.",,The..under<signed`atso.: .dorstands; tl}aulsuch fees;-as-:maybe:-.slue;:.Will.be.id'entified~t iiite time of permitting. It lest'u'r.`ttieryuribers'tob th ���'(isportation:Impact•fees and.ResourceAecovery. Fees must be-paid prior to ­iilrecelvil9aR"certi#icn#eof.occupiye';oriiaipovrer:rease: ciftt .pr.;ojectdiiesrotinvof=uea certificafe6foit�ipaicjror fees a release,most fees amust b a pal prior to,permit rssuant e. furthermore;_rf Pa'scoxCounty Water/Sewer Impact Ixe i i�issuanc,0In accordance appllcdblb.Pifs,'oiCounty.ordinandes:. , -C STR CTION t:`iEN EAVID{Che ter:T lorFiita S#atuteswas�ameridecl): Itrreli atior ofwork4s,Z,500,,. aenmore, I certify::than l:ptlie.appli ai t;.have :ti"eeu prouided'vuith'.'a: copy>of;�thery"t brida RConstructipn-Lien Law,-Homeowner's Protection Guide"prepared,by#he:Florida:ttepartment.of Agriculture'and Consumer'Affairs..=:If thepplikntasa+,ffteone other than;the"oitiner?';tNlvertifji'!t#a tia "e bteirie �a ot:iy'ofw'the�al ova�tlesciitierl tocument:and promise in good faith to deliver it to the"owner.:pnor tot comrixo gMent. C,QN "R)4CT4R11'i•:;, ,�certifal:th tail tt for et�oi :in,thistiap l�"O'tto.0 s; acutete<arad tnat<,alX�uuork will}tie dorie.'iri compliance wit'.all pp crib !j- ws�regulatingtcon traction;zonirig errs lanW evelopmentfa, p lcation is hereby made to obtain a permit tag'd`a��wor a ii�6�rriddIi&F6%V%4ikdreafed. 1 certifyt#hat no work or.installation has commenced.prAor to issuance:of a..perrn t:and..that all work wiff-be,perform d=-ta�meatstandards of ail laws regulating ccarrs#ruction,.4bunty and t�code ;.:zo�iir�i�,iregulations.4rtt#y`iend�tlevetbpment-regulations in the jurisdiction.-4 also certify that I understand:that the�regurations'of other:government!agencies4nay app{..-th-elintended work, and:that.it is my responsibility..to ldentify'what actions,,;L auat�take.tdbe:in compliance. $uah agencies rriclUde but areyno#rlmmited to: Department of Envitonmerdgl'�'Protection-Cypress• Bayheads, WstlancL Areas rand Environmentally Sensitive Lands,'WaterMJaste. a `: .r:at ent.,, i ''. Southwest Florida Water Manag:ement District*Wells, Cypress,..Bayheads, °fWe#land Areasi "Altering Watercourses. I' Army Corps,of-Engineers-$J0"�11ls;:Docks,:Navigabld�Waterways Department WHeolft geh'a ilitative� Weiis;.�Wastewgt0t=Tre9tment, Septic Tanks . USEhVironrral'eritalPdteetie s genc�y-Asbesttis�abatement:: « ll .... . - Federa�'A�atii5ii A°cittiorfytnrays ' that ot ggg �toheusesnd wor," oic&fii:I under `Usd it - ff � sf one"V"•uril sa*X0 essl�permitted;.,. if'tFie-fill"itiateiiat;,is,to.,t7e used .in i:lood done �;Ah,. it is understood`tFia# a drainage.plan' addressipg a ."compensating vdiili "vGllbyes�ubrnttd'at'�time°}ofpermittri , rhjoh l ;:prepaxedrytty= ;pr.,ofe&signal engineer licensed by the State of Florida. - Uthwi€i11,mater aF s;ta;ber t},s. d�; i�flood. i e ;°in connection with a permitted building-using_�ti�+�<Snt�ilV .,. , -I construction,.l;certify'',that 9litinr Il eeused only:tAfllfoie ar4&i ithi A xe�steml all:;. if'-fll:material -is:t0,:.be__uspdAftn any area, U certify•that. use.of•such'-.frll:will not adversely 6ffect.,adjacent :.properties:_ iftise of filiisouQd:to:adoersely 2iffectadja+degtroiii rios;�.#iii�:�ouvraer maycbe-ci#ed for violating the conditions of-the building.per:.mit=issued..undgrkthe-attached permit-application;for lots-less than .acre­1Wltich=arewv_.I unite ;byi fill n� ngIneered; ta.10, a plan is required. if I am�the AGEi�I'��+OGRK�H> ':OVIIVER,1-tirtimfse in good faitk-JriforraAhzD-wnerrzf th :peemlttingwconditions set forth in this,affidavk.prior to-commenc)hg�cons#ruction. ! understand.that a separate permit:may be required for electr1cal?,stork, plumbing'.:signs; welis,:;poois 'air conditioning;..gas,•;or other•instaHatmons»ni t s0ectiealiy��rmciuded,ins-thos pplleation. A permit-issued,:shail,t e.•construed:-to be aaicense to•proceed�with?.the•work•and not.as authority to violate, cancels alter,;or:.. seVask e-any'proirisions�af th s�ta6hriicaf co.-dsy,nors'half,ssuance of•ia-permit--prevent.:the;Building Offclal kom#hereafter; requilling.a�corrrection-of,errors=in plans, construction or violotionsw anycodes: .Every-perniit•rissued shall'become'•invalid unless-the•-work.authorized-by.zsuch:,perr it is commenced,-within..six.month_s.•..of permi Jssuacloe,or:.if,::work.;author-*'.ddlby the-permit°is-suspended-or'aoandoned-for a'perkidof..six.(6)months after•the'tmme tfie:Vrrork is commenced:'`:- extension maybe requested,=•in-writing #rom:thewBuildingnOf dial-f sriaa p4blhod not:to exceed ninety(90)days and will demonstfbte .�. -. justifiable_causefoi���tieextersri:}zlfwor=k�ceases:for'ninetj%�'d)Rconseeutmue.days,;the:jobisconsidered:abandonasi: - WARN.N.G�tQ:E?WIiIER * }UI fAtt URE;TO:RECORD-, 3VCtTti QF CQMME i _EMENT ItAY-RESIIL'I*I "YQtIR t OI;t R 3,ti. 7 +2 N. ' ! Alt RAYiNGt7a11V� E�FOR 1MPitO� NC1ifS T' �(, , It,1sR?IE ' f iF;'Y" {1 T D;fi.O:5 T ` F11ifAF1lt11( Ctt7' . -1AfITH YOUR;I ENDIsFts '14 W � FORN1I�iE d"O'7E412 C°Oi2C1JN'G?Yi U1t IVbISiC {0. COtIAI EN4EMENT. OWISfElt O0,A49N7;. Subscrtbedt aad<siivorr� �(of4 ff%r#r ed}t 8foce,r»e Sii[isMIM andi�'sworn t,�di ifiiriieit)befafie'.s»'e this� Who Rare personaiiy known to me or hasthave produced Who is/are.personally,knowmtaWme'or"fiasltfavtproduced'° as identification. s;lder�t;8c�►tiori:`° ______Notary Public . .: NotaryeP�lblic .. _ .. Commission No. Commission No. Name of Notary typed,printed or stamped ..:Nome of;,otary«typed,Ante49nitunpe�!};<.:. _.. . TRIPLE CROWN ROOFING INC. 39246 SOUTH AVE ZEPHYRHILLS,FL 33542 813-715-4617 STATE LICENSE#CCCO49370 WWW TRIPLE-CROWN-ROOFfNG.COM/LNAULT1963@AOL.COM SPECLULZING IN METAL ROOFING SYSTEMS NAME: PHONE: DATE: Donald Frost 813 778-9731 6/15/2020 STREET: CITY: STATE: Zip Code: 5533 91h St Zephyrhills Florida 34542 COMPANY REP: EMAIL: John Cherry 813 949-7594 We hereby submit specification and work description: COMPLETE REROOF REMOVE METAL AND INSTALL WITH TRI COUNTY METAL'S ULTRA-LOK RIB PANEL 26 GUAGE 36"WIDE ROOFING AND RIDGE VENT AND -QvHLL FINISH) 1. REMOVE ALL OLD METAL PANELS AND DRIP EDGE VENTS,BOOTS AND HAUL AWAY ALL DEBRIS (ACCORDING TO FLORIDA BUILDING CODE) 2. INSTALL NEW BOOTS&GOOSE NECK VENTS AND DRIP EDGE(ACCORDING TO FLORIDA BUILDING CODE) 3. INSTALL 26 GUAGE 36"WIDE`RIB PANEL ROOF SYSTEM OVER BATTENS(ACCORDING TO FLORIDA BUILDING CODE) 4. INSTALL ALL NECESSARY ACCESSORIES NEEDED TO COMPLETE INSTALLATION OF METAL ROOF WITH RIDGE VENT SYSTEM AND CORE DEFENDER PAINT(ACCORDING TO FLORIDA BUILDING CODE) ANY ROTTED WOOD REPLACEMENT IS A EXTRA COST OF$65 PER SHEET OF PLYWOOD $4.50 A FOOT FOR 1 BY'S OR 2BY ALL ROOFING PERMITS,MATERIALS.LABOR&DUMP FEES INCLUDED 10-YEAR TRANSFERABLE LABOR WARRANTY FROM TRH'LE CROWN ROOFING _ ALL TRI COUNTY METAL WARRANTIES APPLY THE ABOVE DESCRIBED WORK WILL BE COMPLETED ACCORDING TO SPECIFICATIONS,FOR THE SUM OF ($11,550) PAYMENT TO BE MADE AS FOLLOWS: ($5,775) DOWN PAYMENT,THEN BALANCE OF($5,775) DUE UPON COMPLETION NO ORAL AGREEMENTS HAVE BEEN GIVEN OR ACCEPTED. THIS WRITTEN CONTRACT IS THE ENTIRE AGREEMENT COVERING ALL THE WORK TO BE PERFORMED AND/OR MATERIALS TO BE FURNISHED.THE WRITTEN PORTION ABOVE IS THE ENTIRE CONSIDERATION FOR THE AMOUNT OF THE CONTRACT.PURCHASER MAY CANCEL THIS CONTRACT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE PURCHASER SIGNED THIS CONTRACT. IT IS AGREED: Contractor will do all said work in a good and workmanlike manner and in strict accordance with the ordinances, rules and requirements of the city,Town or Village,wherein the above-mentioned property is located. If purchaser should cancel this contact after time stated above,the Purchaser agrees to forfeit down payment paid. In the event it becomes necessary for Contractor to employ an attorney to collect any sums due the Contractor pursuant to this contract,then the Purchaser shall pay all reasonable attorney's fees incurred by the Contractor.This contract shall not be binding upon Contractor until accepted by them.Upon such acceptance by said company,this contract shall be binding on me/us without any further notification to me/us. The undersigned property owner agrees that this contract may be assigned for the performance of the work and labor required by the description of the work to be performed.Upon assigned the parties hereto consent to the performance of the work by and payment to such assignee of the amount of this contract.Any Alteration or deviation from above specifications involving extra costs will be executed only upon written orders and will become an extra charge over and above the stated contract amount NOTICE M THE BUYER:(1)Do not sign this contract before you read it or if it contains any blank spaces. (2)You are entitled to an exact copy of the contract you sign.(3)Under the law you have the right to pay off in advance the full amount due and under certain circumstances to obtain a partial refund of the time charge.Owner acknowledges receipt of a true copy of this CONTRACT. ✓ 1 P CHASER ( 1 DATE rip a rows Roofing,Inc. DATE PURCHASER DATE This contract is enforceable only when accepted by management of Triple Crown Roofing Inc. INSTR#2020110179 OR BK 10134 PG 2490 rage 1 of 1 07/09/2020 01:41 PM Rcpt:2180473 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller PermR No. Pascal W No /L.Yo a/-aDtd /Q/o0—G dip NOTICE OF COMMENCEMENT stator 4 CCU*or 1�19SG'0 THE Ut1DER51GNED harety glues nogm that improvmnardu�be made to certain rw1 psapsKy,and In acmnfasoa with Clrgpt1 M,Rowe midutes, the fWofdrtp mfameton fs prrnided In We Notion of Conroon meot 1. 1)e4a"on d RtopMy.Pamd Idmitffl Zft No, ') a S"dAddmsx S4, L 2 Gtmerei 0e8Mpdat d tmprOvmne►d I�G�DrD 3. OxMw IInlnmratton or Lessee Crrfar n 1t the Lessee mntracLed for the knpim mmrt !+O»t> d Ot C tri rw J�tDi� ' Addreaa�3 CRY mernafnRrapedy:-- Name of Fee SimpleTktefotder: (If dJt vd from Owmer noted abaft) Address7A100te city star I 4. Contractor. Addrrzss CW slat CoTelephroneNo.: 8/3 ''!/5- �6/7' ! s sanity Name 0 i Address coy slat ! Amount d Bost Telephone No. a, Lendar, 7� Name /i Address COY State Lendm's 7elophone ft: 7. Persons vtaibt the State of Ftmids daignetd by the aw1w upon wtuxn rhottces or other doaonmxs may be served as prmlded by Sscdon713.13{t)(e)nFlodde Name Addreoa Crly state Telephone Number of Designated Perm: �Jj & in a&Won In hbrtsea,the owner daegnates 66rd of- to eml e a copy dthe Usi oes Notice as p vWded in Section 71313(1)(b),t'W40 SWUtas, Telephone Nuniberof Person orEnt3tlr UeSigr+ated by Oman. &' EWrrvian date of NoUm of Cornamr nnerd{the mpbaaon data may not be befat the comphslicn of cens6udion are final paymcrd to the coma".bid uta be one yea"frmn the dot draomft Lmku a different dale Is spediNWr . WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EMRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS TINDER CHAPTER 713 PART I SECTION 713.13 FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR m movENENTS TO YDU�t PROPERTY. A NOTICE OF COMM-�9 E MUST BE RECORDED AND POSTED ON THE 408 SITE BEFORE THE FIRST NSPEMON,IF YOU INTEND TO OBTAIN FIKMONG CONSULT WfTM YOUR[.ENDER OR AN ATTORNEY BEFORE COMMENCNG WORK OR REOORDNG YOtR NOTICE OF COLtMENCB}ENT. Under peruty dperjury,l dmdare that 1 have read the foregoing rrotice.�and OW the feces stated thmdn are true to the bast td mY knowledge and beUeL COUNTY OF PASCO X /STATE OF FLORIDA &%FN �. Sigratuta of Omm or Lessee.or Owners or Lessee's Autadzad dateed0' . ^- ' Thefoteoayep ftv mettwapadmoifladpadbelaematlda daycd 20jQlry 'm (typeofauthaft.&9,Officer.tuftt.oaco yin taco for PercaieIIylCnorse D$Pioditoedtdmtafice3ldttE3 Naffirysignshue Type of idenaceflon Prod,mad-tJA Name(PdM) mobiry PUmIC SilIE9 tt}PfAmftkW . MepBn M fiiley My tonUnA6116n GO 25U22MO2 epdataarcabol�nsrd�c1DM State Of Florida,County Of Pasco This is to certify that the foregoing Is a true and correct copy of the document $ .... on file or of public record in this office. Ulki my hand d o clal seal this L � of< < 2 les,Es :, lerk&Comptroller fir ,® p, FI rids e®� By , Deputy Clerk V FLORIDA PRODUCT APPROVAL Gulfcodft SUPPLY & MANUFACTURING GULF • GUAGE GULFRIB TM PANEL OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.22 R3 TM Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC. 26 Ga. GulfRibTm Roof Panel over 75/32"Plywood Florida Product Approval #11651.22 R3 Florida Building Code 2017'4LL WORK Per Rule 61 G20-3 CO D'es Ft SHALL CCU, Method: 1 —D A/V®tie CE'tFCrR"fC/1V ®�OEF�EVA141jVG OR®'1�gNcCs OI�ziPl ie Category: Roofing Subcategory: Metal Roofing Compliance Method: 61 G20-3.005(1)(d) RFV NON HVHZ G+/ OJL Product Manufacturer: c�MiN��yl� Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 ;`�OPN�E�S,•k�,y Engineer Evaluator: =*; NO 75519 _ Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 0' STATE OF Valiclator: Locke Bowden, RE. #49704 '���%s�NAL ENGO/05/2017 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 5 FL#11651.22 R3•OCTOBER 5,2017 PRODUCT . • KURN • ® • , . • , , . • • • ® . G61C®ast SUPPLY & MANUFACTURING G U LF-1 • GUAGE GULFRIBTM PANEL OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.22 R3 TM Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: GulfRibTN1 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/" Major Rib at 9" O.C. Panel Fastener: #9-15x1.5" HWH with sealing washing or approved equal 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum'S/32" thick,APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2017. Design Uplift Pressures: Table"A" Maximum Total Uplift Design Pressure 69.25.-psf` 1.59.25 psf;: Fastener Pattern 9"-9"-9"-91, 6.5"-2.5"-6.5"- 2.5"6.5"-2.5"-6.5" Fastener,Pattern Spacing 24".O.C. 12,',`b Design Pressure includes a Safety Factor=2.0. FL#11651.22 R3•OCTOBER 5,2017 PRODIUCTEVALUAT- 10114 ® . KUHN ENGINEERING,, LIX SUPPLY & MANUFACTURING UC G6ilCoz& GULF '-, GUAGE GULFRIB TM PANEL OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.22 R3 TM Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0062T-07A, B, Dated 02/19/2007 2. Certificate of Independence By Dan Kuhn, P.E. (FL#75519)Q Kuhn Engineering, LLC (FBC Organization#ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. FL#11651.22 R3•OCTOBER 5,2017 'PRODUCT es EVALUATION ■ . s ENGINEERING,KUHN Gull® Cast SUPPLY & MANUFACTURING V L. 1i GULF L;- L 27 • GLIAGE GULFRIB Tm PANEL OVER • • 1 FLORIDA PRODUCT APPROVAL NO. 11651.22 R TM Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design.The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.22 R3•OCTOBER 5,2017 PRODUCT ® • REPORT 1200 CLINT MOORE RD. SUITE 9, BOCA • • ® . . . : ' G61iC'Woas'\t SUPPLY & MANUFACTURING . ■ , � ■ ■ • , � ■ ■ • • 1 PSI•!. � � �..' � ..�.' h� Tlvl ENGINEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 15/32"Plywood Buildings,having a Roof Mean'He'ight<-.20'-O"; Roof Slope: 2"%1'2" - 12"/92" Gable or Hip Roof;Wind:Speeds 1207 180mph, Exposure:C, Risk Cato- II, Enclosed Buildino',based on Florida Building Cod le.2017: 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN- (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 1 , #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",-TYPE 1 '24";TYPE 1 24 TYPE 1 24",TYPE 1 24",,TYPE T ZONE 2 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 2 ZONE 3 #9-15x1.5" Plywood ' 24",TYPE 1 24",TYPE 1 24",:TYPE 1 12",TYPE 2 12",TYPE 2 '12",TYPE 2 '12",TYPE 2 1.)PANEL DESCRIPTION:GULFRIBTM' MIN.26 GA., GRADE 80,36"COVERAGE,3/4" TALL. 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.)PLYWOOD DECKING: MIN.15/32"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. ZONE2 HIP ROOF Note:Dimension(a)is defined as 10%of the minimum width of the building or ZONE 3 T I 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be -----------------> --J a less than either 4%of the minimum width of the building or 3 feet � TYPE 1 FASTENER PATTERN RIDGE �i � 9.1 9° 91, \ \-- ------� I � IAtP.n.l Lap I ZONE 1 \\ \\\ L Cont.Tape Seal for use on Slopes less than 3:12 \ \ (1)#9-15 x 1-1/2'w/Sealer Washer @ 24'O.C.Max. SAVE -ZONE 2 65TYPE 2 FASTENER PATTERN GABLE ROOF 65" 25°{— . .—{ .5F .5"7 2.5"T-6.5' 2.5° - ----------------- — . i I I I I RIDGE L Cont.Tape Seal for use on Slopes less than 3:12 (1)#9-15 x 1-1/2'w/Sealer Washer @ 12'O.C.Max. -----------------------� — a ZONE 1 I I +--\--------------------- "-ZONE3 \-EAVE FL#11651.22 R3•OCTOBER S,2017 ENGINEERING,KUHN