Loading...
HomeMy WebLinkAbout20-403 D h iO rl`uiiiun City of Zephyrhills PERMIT NUMBER �M• - 5335 Eighth Street Zephyrhills, FL 33542 BNR-000403-2020 3 - Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 08/11/2020 Permit Type: Building New (Residential) Property. Number Street Address 32 25 210100 01900 0120 35583 Burma Reed Drive Owner Information Permit Information Contractor Information Name: D R HORTON Permit Type:Building New(Residential) Contractor: D R HORTON INC Class of Work:SFR Construct Address: 12602 Telecom Dr Building Valuation:$107,000.00 TAMPA,FL 33637 Electrical Valuation:$6,800.00 Phone: (813)549-1968 Mechanical Valuation:$7,200.00 Plumbing Valuation:$4,800.00 1 (/ Total Valuation:$125,800.00 Total Fees.$14,609.69 Amount Paid:$14,609.69 Date Paid:8/11/2020 2:07:38PM Project Description CONSTRUCT SINGLE FAMILY 2,238 SQ FT Application Fees School Impact Fee $8,328.00 Transportation Impact Fee-City $36.32 Transportation Impact Fee $3,595.68 Electrical Plan Review Fee $37.00 Mechanical Permit Fee $76.00 Public Safety Impact Fee-Police $264.00 Mechanical Plan Review Fee $38.00 Electrical Permit Fee $74.00 Plumbing Plan Review Fee $32.00 Building Permit Fee $565.00 Driveway Fee $45.00 SIF 1 percent Fee $83.28 Public Safety Impact Fee-Fire $273.00 Address Fee $30.00 Public Safety Impact Fee-Admin $26.35 Building Plan Review Fee $282.50 Park Impact Fee-Single Family/Townhome $769.56 Plumbing Permit Fee $64.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE (I • FOR GITY OF • HYRHILLS BILLING CONTACT DAVID GUDE D R HORTON INC 12602 TELECOM DR TAMPA, FL 33637 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00000467 08/06/2020 08/06/2020 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-000403-2020 Address Fee $30.00 Building Permit Fee $565.00 Building Plan Review Fee $282.50 Driveway Fee $45.00 Electrical Permit Fee $74.00 Electrical Plan Review Fee $37.00 Mechanical Permit Fee $76.00 Mechanical Plan Review Fee $38.00 Park Impact Fee-Single Family/Townhome $769.56 Plumbing Permit Fee $64.00 Plumbing Plan Review Fee $32.00 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Fire $273.00 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 SIF 1 percent Fee $83.28 Transportation Impact Fee $3,595.68 Transportation Impact Fee-City $36.32 35583 Burma Reed Drive Zephyrhills, FLORIDA 33541 SUB TOTAL $14,609.69 REMITTANCE INFORMATION TOTAL $14,609.69 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 August 06,2020 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 t, i PASCO COUNTY, FLORIDA Permlt No. Date Permitted :Z Builder Name/Owner Name Control#' County Parcel No. 60— 07 `M-012-b SubDiv: Address/Location s3 ClassificationCrype of Use t,71/1 TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2? Exempt ❑lfes [] No How Determined Impact Fee Amount $.gl Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Horne I (058) Other Residential 123) Collection Fee Exempt [1 Yes Q No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT Exempt ❑Yes ❑ No How Determined'* LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE 13EEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Achnowiedgemant below does not Imply acceptance of concurrence,but simply receipt oft copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for some. DATE RECEIVED BY RECEIPT NO, DATE BY it # Single Family Dwelling Plan Review Comments 1. F.F.E..shall be a minimum of 8"above the road elevation and.an engineered site plan. I Lots shall be graded to.coriiply with R401.3 -of the F.B.C.. 3: Compaction test required if 24" or more of fill dirt is brought in at any one place. 4: Tie in survey ,required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides of driveway_ thru the sidewalk_shall have expansion material. 6. All setbacks shall be met. T. All property markers shall be uncovered.and marked At'time:of first inspection. 8: All A-.D..A.'requirements shall be met: 9. .No electric,.plumbing;mechanical,or framing shall be:covered without an inspection.and . Approval first. l0:.All Garages shall comply with section R302:6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subiect.to mechanical.damage unless protected by approved barriers. M303:4 of the F.B.0 12. water heaters shall comply with section P607.3 of the F:B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1 . 14. Return air in all bedrooms. F.B.C. M1620.4 1.5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16: All glazing requirements are to be in accordance with R308.4 of the RB:C: 17. All means of egress are to be in accordance with R311 of the F.B.C.- 18. "Green gypsum.board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. 19:.Combination-type AFCI breakers are required at all locations requiring an AM type breaker. . 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating. or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical; and electrical shall be separate_from unit to unit: This includes all underground plumbing And electric. 22. All 2016 N.E.C. Codes will be enforced:- 1 . 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development_Code, lots_ shall.be sodded before_ final at least 10 feet around the structure: 25-. R403.5.3Hot.water.'pipe insulation Insulation for hot Water pipe With a minimum thermal resistance (R-value) of R-3.sliall be applied to the following:' -Piping 31.inch (1.9.1 mm)and larger,in nominal.diameter.- Piping,serving more than one dwelling unit: Piping located_outside the conditioned space.- Piping from the water heater to a distribution manifold:. Piping,located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower door test shall be pridAded:before' C.O: 26.A copy of the enery_cacls shall be with uerniit at all times -27. Copy of final insulationreport-shafl be provided ivith permit before fnaL . 28. No fence,pool onscreen enclosure .is issued ivith:this permit~ F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code Oh Edition R.O.W.-Right of Way A.D.A.=Americans With Disabilities Act N.E.C.-National Electric Code (2016) City of Zephyrhills Permit Application Fo»n 3-780-O021 Building Department DateRec, Phone Contact for Permittin ownetr's Name owner Phone Number I ctci 2, Fee Sim pie Titleholder Name IS-ri XyLe— Owner Phone Number Fee Simple Title holder Address AN � ouBom1oxoN P/g«CELOD# (OBTAINED.ROM PY TAX--NOTICE) _ WORK PROPOSED eewcomsTn Aoo6ALT �---| SIGN �--\ [--1 DEMOLISH INSTALL �_] REPAIR PROPOSED USE �--1 � SFR �—� COMM F---| oTHB7 TYPE OF CONSTRUCTION rZ BLOCK �—1 FRAME �--� STEELBUILDING SIZE F_ SQ FOOTAGE E4�1 lZi HEIGHT N. �_�BU|LD|NG VALUATION OF TOTAL CONSTRUCTION [--lELE�T�|{�� AwP6ERVCE F--1 PROGR5GGENER8Y �—� YV.R,E.C. ___ =PLU| B|NG *� f03[—�lMECHANk�\ \CAL|NGTALLATON �—�GA8 F-2111, ROOFING F—1 SPECklLTY [--| OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO - - - - BUILDER COMPANY SIGNATURE nso/anEnso L_Il N_ Fsftcunnsx L_l/N_� xdd,oam Uuen�e# . .- . . / ELECTRICIAN COMPANY []S�A( Eledri C SIGNATURE ReomrEnEo 'y/ N1 ' peem)nes^ Address Licanan# [EE 0 oa PLUMBER COMPANY SIGNATURE REG/aneeEo 'FEEounR�ta I Y|1N_1 1­/ Address MECHANICAL SIGNATURE REGISTERED , �^�[�_1 —LL/N�_� Address � Unon9o# OTHER COMPANY SIGNATURE ns�/orsn�o L,1�_�_� FEsconmsx I _y/1__�� Addpoms6vu Uoonse# RESIDENTIAL Attach(2)Plot Plans;(%)sets of Building Plans;(1)set of Energy Forms;R-O4N Permit for new construction, Minimum ten<1O>working days after submittal date. Required onnihn.Construction P\ous'Stonnvater Plans v/Silt Fence installed, Sanitary Facilities&1dumpater;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(1U)working days after submittal date. Required nnoi0a'Construction Plans,Ghnnnvater Plans v/Silt Fence installed, Sanitary Facilities&I dumOster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT sets of Engineered Pkm. ""pRoPERrY SURVEY required for all NEW construction. ' Fill out application completely. Owner&Contractor sign back nf application,nmmrized . If over*2sno^a Notice or Commencement isrequired. (AIC upgrades over$75oo) Agent(for the contractor)or Power of Attorne�(for,the owner)would be someone with notarized letter frorn owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) RamofsJshingles Severs Service.Upgrades A/C Fonney(P|ot/Sumey/FnotaQe) ` Driveways-Not over Counter ifon public madways.00edoROW ' - - . ` NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations, The undersigned assumes responsibility for compliance with any applicable deed restrictions. ^ UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a -contractor or' contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as.required by law, both the owner and onnboohor May be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing-Section at 727-847- 8009, Furthermore, if the owner has hired a contractor or cont[antorg, he is advised to have thb contractor(a) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contnactor, that may be an indication that heia not propar|y]7oenaad and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES l88P/\CT AND RESOURCE RECOVERY FEES': The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new bui|dinAe, change of use in existing huUdinga, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07' as amended. The undersigned also understands, that such feem, as may be due' will be identified at the time of permitting. It is further understood that Transportation Impact Fees'and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" final puvvar release. If the project does not involve a certificate of occupancy or final power.release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must bo paid prior to permit issuance in accordance with applicable Peaoo [|ountyondinancea. CONSTRUCTION LIEN LAW (Chapter 713. Florida Statutes, asannended): If valuation of work ia $2.5OO.DOormore, | certify that |' the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and {}oDaunn9r Affairs. If the applicant is someone other than the"mvvnar", | certify that | have obtained a copy ofthe above described document and promise in good faith to deliver ittu the"mmner"prior toco0rnaAmamenL C[}NTRACTC}R'S/ODVNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable \avva regulating oonoboct\on, zoning and land development. /\pp\\ootiun is hereby made to obtain a permit to do work and installation as indicated. \ certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all |smve regulating oonstruo§on. County and City codes, zoning regulations, and land development regulations in the jurisdiction. | also certify that | understand that the regulations of other government agencies may apply to the intended vvork, and that it is nny responsibility to identify what actions | must take hobeincompliance. Such agencies include but are not limited to: - Department ofEnvironmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,VVater/WaotewutarTreatmeDt. - Southwest Florida VVate, Management District-Wells', Cypress Bayheada, VVeti-and Areas, Altering VVatorooV[aoa. - Army Corps ofEngineers-SeavvaUo. Docks, Navigable Waterways. - Department of Health & Rehabilitative S ervicea/Environmental Health Unit-VVe||o, Wastewater Treatment, Septic Tanks. - UG Environmental Protecti6O Agency-Asbestos abatement. - Federal Aviation Autho[ih/-Flunxvnya. | understand that the following restrictions apply tothe use of fill: - Use of fill \a not allowed in Flood Zone ''V' unless expressly permitted. - If the fill hnabahal is to be used in Flood Zone "A', it is understood that a drainage plan addressing a '''oonRpeOsediDg Yol.unOe" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State ofFlorida. - If the fill,material is to be used in Flood Zone "/Y' in connection with o permitted building using stem vve|| construction, | certify that fill will be used only tofill the area within the stem wall. - If fill [n8t8rio| is to be used in any area, | certify that use of such fill will not �dvenae|y affect acUocoO1 properties. If use of fill is found to adversely affect adjacent properties, the ovvOor may be cited for violating the conditions of the building permit issued under the attached permit application, for lots \ene than one /1\ acre which are elevated by fill, an engineered drainage plan iarequired. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. l understand that e separate permit may be required for electrical vvorh, p\urnb\ng, signs, vvm|\a, poWa, air condit\oning, gno, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not ao authority to violate, cancel, alter, or set aside any provisions of the technical codes, no[shall issuance ofopernO\1 prevent the Building Official fronn thereafter requiring aoo[nao�onufa�Vna \O plans, oonatnuoUoDur violations of any codes. Every permit issued shall become invalid uO|een the work authorized by such permit is commenced within six months of permit iasuanCB, or if work authorized by the permit is suspended or abandoned for a period of six/U\ months after the time the work is commenced. An extension may be requestod, in writing, from the Building Official for a period not to exceed ninety /00\ days and will.demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. . WARNING TO OWNER, YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT KYOUR PAYING-TWICE FOR|88pR[VEK8E l 'TQYOUBPR8PERTY' IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTOP ,NEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER pmAGENT cum/uxc/o Subscribed and sworn to(or affirmed)beforp mg this Subscribed and sworn to(or affirmed)before me this Who is/are p or has/have prodliced Who is/are personally kno%�n to me or has/have produced as identification. as identification. Notary Public -Notary Public Commission No. - Commission No. Name of Notary typed,printed or st Name of Notary typed,printed or stamped 4 Notary Public State of Florida Michelle MOYes my commission GG 057321 • PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 12, BLOCK 19, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A AND 11B AS RECORDED IN PLAT BOOK 77, PAGE(S) 79-86, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LOT 8 I LOT 7 LOT 6 I BLOCK 19 BLOCK 19 . BLOCK 19 S89'59'20"E I 50.00' LOT 12 '�r9 I BLOCK 19 I 9 5,746 So.FT t I z L� J CV DRAINAGE TYPE A C 0 t O �A�t SO�A 15 30 I I � � I I 1 I . 5.71 COVERED'b 26.7 1�7 ON LOT CALCULATIONS j emu.• c j LOT = 5.746 SQ. FT. 1 12-0' 1 LIVING AREA = 1,672 SO. FT. GARAGE = 432 S0. FT. LOT 11 1 38.67' I LOT 13 ENTRY = 38 SQ, FT. 1n 1 11n LANAI = 96 SQ. FT. BLOCK 19 w i i BLOCK 19 PATIO = 0 SO. FT. PROPOSED DRIVEWAY = 339 SO. FT. 1 P. 4EI B IA C ' o A/C PAD = 12 SO. FT. 1 ~ FINISHED FLOOR I 0 WALKWAY = 28 SO. FT. ET EVAnoN-137.00' IMPERVIOUS = 46% I 0 = 2617 SO. FT. 00 II O SOD = 3.129 SQ. FT. Z llY OFF LOT CALCULATIONS t'O ED j II O RIGHT OF WAY m 900 SQ. FT. Y (n DRIVE APRON 247 SQ. FT. 21 3' 1 PUBLIC S/W 250 SO. FT. 5.75.7 SOD = 403 SO. Fr. TOTALS - 80"•-` AREA 6,646 SO. FT. :.. ,., DRIVEWAY = 586 SQ. FT. RIVE SIDEWALK = 278 S0. FT. 1I SOD = 3,532 SQ. FT. �g Ipog z z 74250' 292.50' PT PC/� �- N8959'20'W - 435.00 ��UNE OF / _ � (REFERENCE BEARING) RIGHT OF WAY PREPARED FOR: BURMA REED DRIVE TRACT 'G' 60' WIDE PRIVATE RIGHT OF WAY D•R'H01M1N' BUILDING SETBACKS FRONT. 20' REAR: 15' SIDE: 5' (50' LOTS) 7.5' (55' & 60' WIDTH LOTS) SIDE STREET: 15' NOTES: 1. ELEVATIONS SHOWN ARE PER LOT GRADING LEGEND: PLANS PROVIDED BY THE CLIENT. 2. ELEVATIONS ARE BASED ON NAVD 1988 — —• — BUILDING SETBACK LINE PI POINT OF INTERSECTION DATUM. _ PC POINT OF CURVATURE CENTERLINE PT POINT OF TANGENCY 3. FOR ALL LOTS WHERE SIDE-YARD — - -— RIGHT OF WAY LINE RP RADIUS POINT SETBACKS ARE LESS THAN 7.50 FEET, A PRC POINT OF REVERSE CURVATURE MINIMUM 5.00 FOOT WIDE DRAINAGE AND PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE ACCESS EASEMENT IS REQUIRED PER PASCO CS TYPICAL COUNTY LAND DEVELOPMENT CODE PROPOSED DRAINAGE FLOW (P CONCRETE SLAB r:•,•`Y'` CONCRETE ) R PLAT CALCULATED THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF •/C. AIR CONDITIONER PGS PAGES BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND S/W SIDEWALK SQ. FT.' SQUARE FEET OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.I.R.M. FLOOD INSURANCE RATE MAP AND IS FOR INFORMATIONAL PURPOSES ONLY. NAVD NORTH AMERICAN VERTICAL DATUM NGVD NATIONAL GEODETIC VERTICAL DATUM THIS IS NOT A SURVEY POEE PRIVIATE NAGE D AINAGETMEASEMENTT THIS IS A PLOT PLAN ONLY D&AE DRAINA En&ACCESSMENT EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M, MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DAZED SEPTEMBER 26,2014,AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS 70 UE IN ZONE'X',AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION.PLEASE CONTACT THE LOCAL F.EM.A.AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF BURMA A5hA 3. NOT VALID WITHOUT THE AUTHENTIC REED DRIVE BEING N8959'20W, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC A M E 1�1 C/�N ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: SURVEYOR AND MAPPER. (FIELD DATE:) Digitallysigned byJamesW r- 3o FEET S U RV I-Y 1 N G �,11 o Boleman SCALE: ,. ON:-US,st=Florida,I—Orlando, 81: MAPPING INC- ' -AMERICAN SURVEYING& APPROVED BY: `B 5°"` ��, MAPPING,INC,cn=JamesW CERTIFICATION OF AUTHORIZATION NUMBER LB16393 `� {,c€ —Boleman, 180820 LOT 12, 3191 MAGUIRE BOULEVARD, SUITE 200 •n;° +; "email=jboleman@asmcorporateco� BLOCK 19 a,,J FIRM JOB NO, ORLANDO, FLORIDA 32803 m (407) 426-7979 Date:2020.06,091600A0 o DATE DRAWN BY: DSEI PLOT PLAN OB 04 2020 JG WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485