HomeMy WebLinkAbout20-552 D
F"onto" City Of ZephyrhillS PERMITNUMBER-:f'
5335 Eighth Street `
Zephyrhills, FL 33542 BNR-000562-2020
Phone: (813)780-0020
Fax: (813)780-0021
Issue Date: 09/10/2020
R ,
Permit Type: Building New (Residential)
Property Number Street Address
32 25 210100 01800 0390 35592 Burma Reed Drive
Owner Information, Permit Information Contractor lriformation
Name: D R HORTON Permit Type:Building New(Residential) Contractor: D R HORTON INC
Class of Work:SFR Construct `
Address: 12602 Telecom Dr Building Valuation:$105,000.00
TAMPA,FL 33637 Electrical Valuation:$7,000.00 (�
Phone: (813)549-1968 Mechanical Valuation:$7,500.00 ,
Plumbing Valuation:$5,000.00
Total Valuation:$124,500.00
Total Fees:$14,599.94
Amount Paid:$14,599.94
Date Paid:9/10/2020 3:08:20PM
Project.Description
CONSTRUCT SINGLE FAMILY 2,362 SQ FT
Application Fees _"
Plumbing Permit Fee $65.00 Address Fee $30.00
Transportation Impact Fee $3,595.68 Park Impact Fee-Single Family/Townhome $769.56
Building Permit Fee $555.00 Public Safety Impact Fee-Admin $26.35
Public Safety Impact Fee-Fire $273.00 Electrical Permit Fee ((-2-JM $75.00
Mechanical Permit Fee t(4 Z� $77.50 Electrical Plan Review Fee $37.50
School Impact Fee $8,328.00 Building Plan Review Fee 32. $277.50
Driveway Fee $45.00 Transportation Impact Fee-City $36.32
Public Safety Impact Fee-Police $254.00 SIF 1 percent Fee $83.28
Mechanical Plan Review Fee $38.75 Plumbing Plan Review Fee $32.50
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
PASCO COUNTY, FLORIDA
Permit No. �
Date Permitted T"�a.CZP7.
Builder Name/Owner Name t K Control#' * _
County Parcel No. 37— 2-5 24 6(00 b t8& 0 c3 tD SubDiv: c5t
4
Address/Locaflon
ClassiflcaflonRype of Usk ��i'`GtT.44,1�1
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z1-36-2 -
Exempt ❑Yes [].No How Determined
Impact Fee Amount . _3 1 37i` Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Famlly Detached House Amount $ —i (, 211
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [ Yes- .Q No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit -Recreation Total
Zone TOTAL AMOUNT
y
Exempt ❑Yes ® No How Determined 12
LIBRARY FEE
Land Adbount Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑Yes ❑No How Determined Total Amount - Cl
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE.ISSUED OR FINAL INSPECTION
PERFORMED UNTIL WtTOTAL AMOUNT-$LISTED HAVE
SEEkPAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,butalmply,recelpt of-a copy of this form;placing
the building permit owner on notice of ihla assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
_ ---- uay oT /_epnyfhU|SPerm1t Application Fax-813-780-0021
Building bepartment
Date Received Phone Contact for Permitti g
owner's Name Ow ier Phone Number
Owner's Add r.'SS Owner Phone Number
Fee Simple Titleholder Name -sn Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 5 �,k,-,C,C?_� -Dvi\f? D ID�)u I- LOT# Rom I
mUaoN1nxON pARoELKD#
(OBTAINED FROM PROPERTY NOTICE)
—
WORK PROPOSED woyoomsrm 8oD�J]' �--1 s\GN F--) �—� DEMOLISH
115'
INSTALL R
REPAIR
PROPOSED USE �—� . SFR 7--1 COMM �--7 OTHER
TYPE OFCONSTRUCTION BLOCK �—� FRAME �--1 STEEL F--\
DESCRIPTION OF WORK 1
`+
BUILDING SIZE SQ FOOTAGE f4_ HEIGHT
=BU(LD|NG VALUATION OF TOTAL CONSTRUCTION
�--�ELECTRCAL AMP SERVICE F--� PROGRESS ENERGY �—1 YY.plE.C.
___
=PLUMB|NG
�—��ECHANk�\ �AL\N8T��L�ODN ���
�__^ _ '—�� *'
�—�G�s ���' ROOFING �—1 � SPECIALTY OTHER
DTHER
���
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YE8 NO
07
BUILDER COMPANY
SIGNATURE nsG/orsnso Fseconneu L_y����
Address License#
ELECTRICIANC)eR I
COMPANY
SIGNATURE �so/orsoso L���L� FssounREh LY_��_J
Address License#
PLUMBER COMPANY
SIGNATURE Rsoonsnso LY/_N_ 'pssnonnt^ L]!/N_�
Address Ucense#
MECHANICAL COMPANY
SIGNATURE REGISTERED ` L����_| psecunnsx [Y/_NLJ
Address � License#
OTHER COMPANY
SIGNATURE nsa/orEnso L�2��_| rEsounnEx L_Z LNL_�J
Address Licenoe#
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set nf .
Minimum ten(10)working days after submittal date. Required orisite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(1O)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed,
Sanitary Facilities&I dumoster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets nf Engineered Plans.
°°°°PROPERTY SURVEY required for all NEW construction. '
Fill out application completely.
Ovmnr&Contractor sign back of application,notarized
If over$250o'allotine of Commencement is nv9qimd. (A/C upgrades over$J5UV)
°~
Agent(forib000ntractor)nrPovwerofAttxne�0orthanwnmjwmo|dbeoomeoneWithnobydzad|eUorfromowmereuthohzinAsama
OVER THE COUNTER PERMITTING (copy of contract required)
Remofsifshingles Sewers Service Upgrades A/C Fenmm(P|ot/Gumey/Foobge)
Driveways-Not over Counter ifon public moUvays..000deROW
' .
` ^
` -
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"daed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired e -contrador or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as.required by (nvv, both the owner and contractor may be cited form misdemeanor violation
under state |ovv, If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing-Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contrecto[8, he is advised to have the contractor(s) sign
portions of the "contractor B|ooK' of this application for which they will be responsible. If you, as the owner n\Qn an the
contractor, that may be on indication that he |a notpnoperly]|uanead and is not entitled to permitting pdvOaQea in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES': The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buUdings, or expansion of existing buUdings, as apaoU]ed in Pasco County Ordinance number 89-07 and
90-07' as onnuOdad. The undersigned also undarutendo, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Feae'and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project doeenntinvo|veocertifnateofoccuponoyor
final power.release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713. Florida Statutes, asomnende6): |f valuation cf work io $2'GOU.00or more, \
certify that \, the app|iuont, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver itto the"m*ner"prior tocommencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has
onrnmenmad prior to issuance of o permit and that all work will be performed to meet standards of all \avva regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. | also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
nnyresponaibi\ib/toidentif/yvhotactionalrnuetbakeboba1ncomp|ionne. Such agencies include but are not limited to:
- Department ofEnvironmental Protection-Cypress Boyheods. VVeUondAreas and Environmentally Sensitive,
Lands,Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayhemdn, VVetiend Areaa, Altering
Watercourses.
- Army Corps ofEngineen*GeovvaUs, OoCka. Navigable Waterways.
- Department of Health & Rehabilitative Sarvioen/Environn7enta| Health Unit-We\|e, Wastewater Treatment,
Septic Tanks.
- UG Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Autho[\ty-Runvvayo.
| understand that the following restrictions-apply totheuse of fill:
' Use of fill |o not allowed in Flood Zone 'V' unless expressly permitted.
' If the fill material is to be used in Flood Zone "A". it is understood that o drainage plan addressing e
"compensating vo\ume" vv||| be submitted at time of permitting which is prepared by e professional engineer
licensed by the State of Florida.
' /f the fiU'0n±er|a| is to be used in Flood Zone ''N' in connection with a permitted building using stem vva||
construction, I certify that fill will be used only to fill the area within the stem wall.
' If fill material is to be used in any area, \ certify that use of such hU Will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots |eea than one (1)
acre which are elevated by fill, an engineered drainage plan iarequired.
\f ) annthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction, | understand that separate permit may be required fbr electrical vvork,
p|u[nbing, aigne, vvaUs' pon|a, air cunditioning. Qao, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not aa authority toviolate, oonue|' mlhsr, or
set aside any provisions of the technical codes, no'r shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
uO|eua the vvnrh authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requeSted, iO writing. from the Building Official for a period not to exceed ninety /QO\ days and will demonstrate
justifiable cau's8 for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned.
.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. YOU INTEND TO OBTAIN FINANCING,ICONSUILT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR-NOTItE OF COMMENCEMENT.
OWNERORAGENT CONTRACTOR
Subscribed and sworn to(or affirmed)beforp m@ this Subscribed and sworn to(or affirmed)before me this
Who islare p or has/have prod1rued Who is/are personally knov�n to me or has/have produced
as identification. as identification.
//P
Notary Public
Commission No. - Commission No.
Name of Notary typed,printed or,st d Name of Notary typed,printed or stamped
/
1
D
Q
i
1 �
Single Family Dwelling
Plan Review Comments
1. F.F.E..shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C.
3. Compaction test required if 24"or more of fill dirt is brought in at any one"place.
4: Tie in survey required before pouring concrete.
5: Driveways require a R.O.W. use permit: All 4 sides.of driveway thru the sidewalk shall have
ekpansion material.
6: All setbacks shall be met.
-7: All property markers shall be uncovered.and marked at time of first inspection.
8: All A:D.A. requirements shall be met: .
9. No electric,plumbing;mechanical, or framing shall be covered without an inspection and .
Approval first.
10. All Garages shall comply with section R302:6 of the F.B.-C. (Fire Separation).:
1.1. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by:approved barriers. M303:4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the E.B.C.
13. Foundation supports for A/C iinits.shall be-raised at least 3"above finished grade. M1308:1
14. Return air in all bedrooms. F.B.C. M1620A
15. Smoke detectors are to be' installed in accordance with R313:1 of the F.B.C.
16:All glazing requirements are to be in accordance with R308.4 of the RB:C:
17. All means.of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board' shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. .
10. Combination-type AM breakers are required at all locations requiring an AM type breaker.
20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating .
or appliances or an attached garage. Thoy shall be installed in accordance with the F.B.C:
21. All plumbing,mechanical; acid electrical shall be separate from unit to unit. This includes all
underground plumbing and electric.
22. All 2016 N.E.C. Codes will be enforced:
1,
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0
24. In accordance with the Land Development Code,lots shall be sodded before final at least 10
feet around the structure.
25.. 14403.5.Mot water pipe insulation
Ins.ulatioh for hot water pipe with a minimum thermal resistance (R-value) of R-3.shall be applied to the
following:
Piping.3h inch (19.1 mm) and larger_in:nominal diame_ter..
Piping,serving more than one dwelling unit.
Piping located outside the conditioned space:.
Piping from the water heaterto.a distribution manifold.
Piping located under a floor slab.
Buried in-piping.
Supply and return piping in recirculation systems other than demand recirculation'systems.
25. Blower door test shall be provided before C.O.
26.A coon of the enerffV eacls shall be with permit at all times
27 Coon of final.insulation report-shall be provided with Permit before flnaL
28. No fence.Pool or screen enclosure .is issued with this-permit
F.F.E.-Finished Floor Elevation
RB.0 Florida Building Code 6'h Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016)
PLOT PLAN
DESCRIPTION:(AS FURNISHED)
LOT 39, BLOCK 18, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A AND 11B
AS RECORDED IN PLAT BOOK 77, PAGE(S) 79-86, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
BURMA REED DRIVE
TRACT "G"
60' WIDE PRIVATE RIGHT OF WAY
(REFERENCE BEARING)
PT _ TS89'SW20'E _ 435.00' PC oa
CENTERUNE OFJ -179.47' �- 755.53'
RIGHT OF WAY
W iz
o GRAPHIC SCALE
18 0 15 30
I
10'PUE
Tn :..': ul Tfl
0''
5.2' 5,2'
., 21.3' .14.0'
COVER 4.3'
ENTRY
LL1
a PROPOSED 1.
LOT 38 ¢ 1 CAU LOT 40
BLOCK 18 a w FINISHED FLOORE BLOCK 18
LEVATION-138.90'
q0
O � o0
Z 39,67' n O ON LOT CALCULATIONS
11.0' 0 LOT = 6,264 SO. FT.
?COVER LIVING AREA = 1,828 SQ. FT.
M ,LANAI GARAGE = 430 SQ. FT.
52' C2&7 `"5.2' ENTRY = 16 SQ. FT.
LANAI = 88 SO. FT.
PATIO = 0 SO. FT.
DRIVEWAY = 328 SO. FT.
N A/C PAD = 12 SQ. FT.
WALKWAY = 28 SO. FT.
Uri u-i N LOT 39 � N IMPERVIOUS == 273730 SQ. FT.
BLOCK 18 SOD = 3,534 SO. FT.
6,264 SQ_FT.f OFF LOT CALCULATIONS
DRAINAGE TYPE A RIGHT OF WAY = 850 SO. FT.
-------------- DRIVE APRON = 228 SQ. FT.
10'FILE A PUBLIC S/W = 25D SO. FT.
SOD = 372 SO. FT.
-.—.—. .—•—.— TOTALS
S89"59'26"W 50,00' AREA = 7,114 SO, FT.
DRIVEWAY = 556 SQ. FT.
PREPARED FOR: ZEPHYRHILLS COLONY COMPANY SIDEWALK = 278 SQ. FT.
LANDS SOD = 3,906 SO. FT.
D•It HORRIN'R, PLAT BOOK 1, PAGE 55
ta�t*i�'a-`s tatt
BUILDING_ SETBACKS
FRONT: 20'
REAR: 15'
SIDE: 5' (50' LOTS)
7.5' (55' & 60' WIDTH LOTS)
SIDE STREET: 15'
NOTES:
1. ELEVATIONS SHOWN ARE PER LOT GRADING LEGEND:
PLANS PROVIDED BY THE CLIENT.
2. ELEVATIONS ARE BASED ON NAVD 1988 — — BUILDING SETBACK LINE PI POINT OF INTERSECTION
DATUM. PC POINT OF CURVATURE
3, FOR ALL LOTS WHERE SIDE-YARD —-u CENTERUNE PT POINT OF TANGENCY
RIGHT OF WAY LINE RP RADIUS POINT
SETBACKS ARE LESS THAN 7.50 FEET, A - PRC POINT OF REVERSE CURVATURE
MINIMUM 5.00 FOOT WIDE DRAINAGE AND PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE
ACCESS EASEMENT IS REQUIRED PER PASCO TYPICAL
CS
COUNTY LAND DEVELOPMENT CODE. PROPOSED DRAINAGE FLOW CS CONCRETE SLAB
PER PLAT
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES ^ CONCRETE (c) CALCULATED
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/C AIR CONDITIONER Pcs Paces OOK
THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND S/W SIDEWALK SQ. FT. SQUARE FEET
OPT10N LIST FOR CONSTRUCTION. ALL BUILDING SET BACK REM.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.LR.M. FLOOD INSURANCE RATE MAP
AND IS FOR INFORMATIONAL PURPOSES ONLY. NAVD NORTH AMERICAN VERTICAL DATUM
NGVD NATIONAL GEODETIC VERTICAL DATUM
EASEMENT
THIS IS NOT A SURVEY PDEE PRIVATE DRAINAGESEASEMENTT
THIS IS A PLOT PLAN ONLY PIE PUBLIC ATE"LLA LANDSCAPE EASEMENT
FLOOD NOTE: SURVEYOR NOTES:
I HAVE EXAMINED THE F.I.R.M.MAP NO.12101CO2881F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE
DATED SEPTEMBER 26.2014,AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT
APPEARS TO UE IN ZONE'X%AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WWH10i
0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND.
GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE
LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
LOCATED EXCEPT AS SHOWN.
BEARING BASIS:
BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF BURMA A!5hA 3. NOT VALID WITHOUT THE AUTHENTIC
REED DRIVE BEING SB9'S9'20%PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC
ELECTRONIC SEAL OF A FLORIDA LICENSED
REVISED: A M R I GA N SURVEYOR AND MAPPER.
(FIELD DATE:) S U IRS/D Y I N G
SCALE 1"- 30 FEET
,eo a Diq,talysg me nedbylasWBnleman
..- �,.�,.. k;
8c MAPPING INC. UN:mUS at=flor da kO Iam}o
�� � �-•ooAMERKAN SDAVEYGtG&MtPPWG,
APPROVED BY: `B CERTIFICATION OF AUTHORIZATION NUMBER L8/6393 ;;:ti'n"�':: MC.—jamesw Bateman, FOR
t „omaiktboleman@asmcorporate.com
180820 LOT 39, 3191 MAGUIRE BOULEVARD, SUITE 2O0 ,;;.• Date:2020.073n2.ovs2.04'00' THE
JOB NO. BLOCK 18 ORLANDO.FLORIDA 32803 FIRM
(407) 426-7979
DRAWN Br. DSB PLOT PLAN D7 29 2020 JC WWW.AMERICANSU VEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE
INsm 2020144171 OR BK 10i 69 PG t6$ Page 1 ar!
' Nt MiSo G%Eq P m County Cieerrk&c mptroile r
P&vdNo, �R�.-f]6LSS ram=Zd Panel lD No-12 IS;-2 e,I MIs Q-33{).
NOME or-toM)bAHNCBB w
State of Florida Comyof Plasm
THE UNDERSIGNED hereby glues notlee thtd t nprwAMM vAll be made to ceft Mal properifr,end to eocm dance w4h Chapter l?%Florida St dLm.
thefoTiawttgbNormatbnfe provtdedia9ilsNotks ofComrtterrcemersr
1. DasalptianofProperty:Parcel Idantrfic0onNo, # y�cj `Fs Qt" �kfQY»Gc�1! 4+1= 1�"
ShdAddless -j`Vp,?,Qp6 ,iT�1_ �2c41
2 Geneml Desaiptlorr of lmpm ernem,New Sing a Famt'iV Re 9denCe
3 Owner tgorrne6on orLessee Mlontration ifthe Lemes omtracM fartha Ir v,,mom
�R Hortcln ins
Name �a�rncv 33837
draw ttgr state
IrMtest In Property: Fee tile__
Name of Fea>»n►Pa Tttlahnider.
Addraw
• (tftfAt�e+dtlomOvarer above} .
4. Cannbador: D.R. Horton_Inc. Skate
126n9ITIOM Drive - 3am 33637 FL
Address y sf
Contradms Telephone Nw
s. Surety NIA
Name
Address MY State
Amotmt of Bond:I MIA Telephone No®
8. lender: NIA
J A
Name
Address Croy Slate
LendetsTelephona No-
7. Pera"wdtdrs the Stub of Flcdda desWated by the owear upon wham noiiaa ov adw doaanerds may be served as PWded by
Sadtott7l3 Florida Sbahates: .
Davjd GUde
Name
196Q2 Telecom Diva Tema 33637 _FL
Addross CIy state
Telephone Nunber olOaslgrretea Person: S'�74Q9720
8. in adcoon to blrnself,ire owner dasignsfa NI of—
to receive a copy of the Usnora Nmkx as prwtded In Saetion 713,13(t)(o),Florida SWIdes.
TelephmeNionberofPerson or En*DesiprtatedbyOwner
9. ExPka6ce debt of Ndoa of Cm=encemart Mm expiration dete stay not be before the eanpWan of mnatudon end final Payment to the
coobadtar,butwil be one year from Ire We afleccoft LOOMS a diHererd dabs Is SPedaed]:
wARAdrtS3 T'O OyUNEIZ: ANY FAYMF3dTS MADE BY THE OWNER APiER THE E7CPiRAT1ON OF TffE hIDTICt:OF COMAIEIQCENIF7dT
• ARE OONSIDERETi IMPROPER PAYMiNNTS UNDER CHAPTER 7t3, PART t, S£•cTtON 7l3.13 FtARtDA SSATUT69 AND CAN
R�ECOLRD�A�Np P POSTED ON�'ItiE OB BITE BFFo $'ME FIRST OINSP�i14�N�1F Y4U t T�F1JD TD aBT�gtNM�CEt�I Q M�UN51s'�T .
Vtltti•t YOUR LENDER OR RN ATTORNEYLhEFORE COMtLENCING WORKOR RECORDING YOUR NOTICE OF CAMAdENGEMENT.
Under pwdtyafpe,17 tdedtarethatI have toad the fores ing ce eammorroamerdandi oft facts stebedtheretnam true to the bad
of my krrowledge end betiieL
STATE OF FLORIDA
COUNTY OF PASCO
Owner or Lessee,of Owners or lessees Authafged
• OfScerfDlrectalPertnertManatier .
AnR'0Rp'jw;l,,W4M-R.Horton.Inc
sl9netort+s .f "
The f0MgoingLnahtanentmasadiowMedged Wore mettdeafayot by
ea As al nt 80ratA41 ((M01out4*,04,,dfficer,bustse; ymfutliar
D,r,.Horton Inc (nameofperty gb�aljflj/promr m rrtwyasv�mrpacursd).
Pawra4 Known IM OR Produced Identf Wbri❑ Ndaty
Type of ldenff6o#on Produced Narno aldr[l>
Wdww�S+�, N�ypnd�lesntearHodda
IVt0orranlMielon�fjQtt67a2t
ES�Yas17ll1Ra2o
wpdatafbcamoticedo