Loading...
HomeMy WebLinkAbout20-583 m o�Ufl City Of Z@phyrhlllS _ 1PER1WIT41NUM98Fk- ' 5335 Eighth Street Zephyrhills, FL 33542 BNR-000583-2020 Phone: (813)780-0020 •' � b;y Issue Date: 09/10/2020 Fax: (813)780-0021 Permit Type: Building New (Residential) Property Number ,° a Street Address: 32 25 21 0100 01900 0170 35633 Burma Reed Drive Owner Information" Permit Information ``•Contractoc.Information­,"­ -,,,," Name: D R HORTON Permit Type:Building New(Residential) Contractor: D R HORTON INC Class of Work:SFR Construct Address: 12602 Telecom Dr Building Valuation:$104,000.00 TAMPA,FL 33637 Electrical Valuation:$6,800.00 /I \ Phone: (813)549-1968 Mechanical Valuation:$7,000.00 Plumbing Valuation:$4,500.00 V' jD Total Valuation:$122,300.00 Total Fees:$14,583.44 j Amount Paid:$14,583.44 Date Paid:9/17/2020 1:02:48PM Project Description `= CONSTRUCT SINGLE FAMILY 1,900 SQ FT Application Fees Address Fee $30.00 Transportation Impact Fee-City $36.32 SIF 1 percent Fee $83.28 Mechanical Permit Fee $75.00 School Impact Fee $8,328.00 Plumbing Permit Fee $62.50 Building Permit Fee $550.00 Public Safety Impact Fee-Admin $26.35 Building Plan Review Fee $275.00 Electrical Permit Fee $74.00 Transportation Impact Fee $3,595.68 Public Safety Impact Fee-Police $254.00 Park Impact Fee-Single Family/Townhome $769.56 Plumbing Plan Review Fee $31.25 Driveway Fee $45.00 Electrical Plan Review Fee $37.00 Mechanical Plan Review Fee $37.50 Public Safety Impact Fee-Fire $273.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER PASCO COUNTY, FLORIDA Permit No. Date Permitted I-Ib=� Builder NamelOwner Name c`J ► or'" Control#' County Parcel No. 32- 2-5 2-1 w 0 a j,)-j Da 0/7 0 SubDIV: Address/Location 35(0 3 3 ,e Classlficatlon/Type of Use I TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑ Yes ❑.No How Determined Impact Fee Amount $. 5.kr 32, Zone No. TAZ: I ! SCHOOL IMPACT FEE' 1 Account (056) Single-Family Detached House Amount $ � (057) Mobile Home (055) Other Residential 123) Collection Fee Exempt [ Yes .❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total I Zone TOTAL AMOUNT $ 76 9.-66 Exempt ❑Yes No How Determined ? LIBRARY FEE Land'Accounf Land Credit Land Total i Facility Account Facility Credit Facility Total Exempt ❑Yes 0 No How Determined Total Afnouirrf' �_ - I RESOURCE FEE- ERU TOTAL AMOUNT i Prepared By Checked By i NO CERTIFICATE OF,OCCUPANCY WILL BE,ISSUED:OR=FI_NAL,INSPECTI'ON PERFORMED UNTIL THE TOTALAMOUNTS LISTED'HAVE BEEN PAIDAND . RECEIPTED FOR 13Y A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does'not Imply acceptande of-concurrence,.but slmply receipt ofa copy ofthis form,placing . the building permit owner on nofico.of this assessment and the condigons of payment for same. DATE RECEIVED'SY RECEIPT NO. DATE BY - ---- UllyOT/-apnvrhU OO� F�����%)� Permit �n�\\��fDD � uu*uz1 Building Department Phone Contact for Permitting Owner's Address 3�_ Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address - SUBDIVISION PARCsLUD# . ~-.~INED_._-PY TAX--_-- VxORKpROPOSBJ wewcomsTn ADOV\[r �--1 SIGN �-� �-� DEMOLISH | \ INSTALL E REPAIR PROPOSED USE = , aFR [--1 COMM �--1 OTHER TYPE OpCONSTRUCTION [-�q- BLO:K F-� FRAME F---1 GTEELBUILDING SIZE SQ FOOTAGE HEIGHT F-1 DESCRIPTION OF WORK ' BUILDING VALUATION OF TOTAL CONSTRUCTION �--lELECTR\C8L AMP �--� PROGRESS ENERGY [--1 YY.R.E.C. Lot �_� =PUJMoiNB [--��ECH�Nk�� MECHANICAL �-� -- �--lGAS F��� ROOFING [--l � SPEC|ALTY �--� OTHER " FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE nsomrsnEo LY/_N_ FEEtp»:mEa LZI N__J Address Lioanse# ELECTRICIAN COMPANY Eler SIGNATURE nsG/orexso LY/ N pescuRasN LS= Address License# PLUMBER COMPANY 14�SIGNATURE REGISTERED N 'FsEcunF�Itl\ LY/N I ~^ Address License* MECHANICAL SIGNATURE REGISTERED ` L����-| FEEounncx N-� Address � License# OTHER ooMpAwv SIGNATURE xeaaTsmso L_Y/_N_| Fssounne^ L_II NL_�J Address du 3 License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(1n)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisionsliarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(1O)working days after submittal date. Required nnaNa`Construction Plans,Stonnvat rP\anovl8iltFnnueinata@od` Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. °°°°PROPERTY SURVEY required for all NEW construction. ' Fill out appUcatinncompletely. ovmer&Contractor sign back of application,notarized If over*2sUo^a Notice of Commencement ismquimd. �JC upgrades over$75V0) � AOent(fxMmconhoctor)orPowarofAttome�(forthnovmer)wmu|dbeanmeone*ithnutadzed|eMarfromovmerauthoridngmema OVER THE COUNTER PERMITTING (copy of contract required) Romofs if shingles Sewers Service Upgrades A/C Fmnmm(P|ut/Sumey/Footage) ^^ Driveways-Not over Counter ifon public madmmym-needsROW ' . ` ^ NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" which may ba more reathctiv�than County regulations, The undersigned aeaumaerespone|bi|ityfovoornpUancovvithany ^ applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: |f the owner has hired anontradoror contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as.required by (avv, both the owner and contractor rn,ay be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing,Section at 727-847- 8009. Furthermore, if the owner has hired a contractor Or coOtraoturo, he is advised to have thA contractor(s) sign portions of the "contractor Block' of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that heis notpropedy]ioaneed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply tnthe construction of new buildings, change of use in existing bu||d\nQa^ or expansion of existing bui|dinge, as specified in Pasco County Ordinance number 89-07 and 90-07. as amended. The undersigned also underotande, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees'and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. |f the project domenotinvo|veamert0oeteofoocupanoyor final povverre|eaae. the fees must be paid prior to permit |aauanca. Furthermore. if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable PaaouOountynrd|nancea. CONSTRUCTION LIEN LAW(Chapter 713. Florida Statutes, as amended): If valuation of work ia $2.5OU.00 or more, | certify that |, the opp||oont, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver itto the"mwner" prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: \ certify that all the information in this application is accurate and that all work will be done in compliance with all applicable ievva regulating oonabzction, zoning and land development. Application is hereby made to obtain e permit to do work and installation as indicated. | certify that no work or installation has oonnnoanoed prior to issuance of a permit and that all work will be performed to meet standards of all \evxs regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. | also certify that | understand that the regulations of other Qovernmant agencies may apply to the intended vvork, and that it is nny responsibility to identify what actions | must take bobeiOcompliance. Such agencies include but are not limited to: - Department ofEnvironmental Protection-Cypress Beyheoda, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management [}inthct-YVeUa' Cypress Boyhaads, Wetland Areas, Altering Watercourses. - Army Corps ofEngineera'SmewvaUs, Docks, Navigable Waterways. - Department of Health & Rehabilitative Servicao/Environmental Health Unit-We||s, Wastewater Treatment, Septic Tanks. - UG Environmental Protection Agency-Asbestos abatement. - Federal Aviation Author\tv'RUnvvaya. \ understand that the following restrictions apply ho the use offill: - Use of fill ia not allowed in Flood Zone"\y' unless expressly permitted. ' |f the fill hnataha| is to be used in Flood Zone "A", it in understood that a drainage plan addressing a "nompenaating volume" will be submitted at time of permitting which is prepared by a professional engineer r licensed bv the State ofFlorida. ' If the fill'material is to be used in Flood Zone 'YY' in connection with o permitted building using stem vvo|\ construction, I certify that fill will be used only to fill the area within the stem wall. - If fill rn@teha\ is to be used in any area, \ certify that use of such O|| Will not adversely ofhaot acUooeOt properties. If use of fill is found to adversely affect adjacent propertieS, the owner may be cited for violating the conditions of the building pann(t issued under the attached permit application, for lots |oas than one (1) acre which are elevated by fill, an engineered drainage plan is required. \f | onnthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction, | understand that e separate permit may be required for electrical vvnrh, p|unobing, signs, vve||S, poo|a, air conditioning, gao, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not aa authority toviolate, o8nonl' a|tar, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuonoe, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (QO) days and will demonstrate justifiable cau'oe for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. . WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. - - OWNER OR AGENT � CONTRACTORSubscribed and sworn to(or affirnied)beforp mg this Subscribed and sworn to(or affirmed)before me this Who is/are p or has/have prodtrmd Who islare personally kno\�n to me or has/have produced as identification. as identification, Notary Public Commission No. Commission No. Name of Notary typed,printed Name of Notary typed,printed or stamped L,, Py, Notary Public State of Florida 401e, a of Michelle Moyes My Commission GG 057321 iNSTR#2O2O1 4417O OR BK 10169 PG 467 Page 1 of 1 09/02/2020 09:28 AM Rcpt:2199486 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez•Sowles,Esq.,Pasco County Clerk&Comptroller Permit No. ParceliDNo 3? NOTICE OF COMMENCEMENT state of Florida County of_ _QaSCO THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes, the following Information Is provided in this Notice of Commencement: L 1. Description of Property: Parcel Identification No. i lad- J3 Tk 4..l'� C -�►NO-17IO& r Y f(u StreetAddress:3S303 _`lw r_%-� �nr1 2.' General Description of Improvement New Single I"gmily ggsidence 3. Owner iriformafion or Lessee information if the Lessee contracted for the fmprovemet* D.R. Horton, inc Name _f 2f Tplennm r)r4vp Tmmpa ,33637 Address I City state Interest In Property. F5 Ss iMple Name of Fee Simple Titleholder. (if dtfferentfrom Owner listed above) Address City State 4. contractor D R Horton inc 2602 Tel=rr Ddy-et Tampa 33637 FL Address City state Contractor's Telephone No.: S. surety: N/A Name Address City State Amount of Bond: S N/A Telephone No.: 8. Lender. NIA Name Address city state Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: . David Gude Name 1QQ2 jelecom Qjjye Tampa 336377 FL Address City Sty Telephone Number of Designated Person: 'l� 3_740-9720 8. In addition to himself,the owner designates N/A to receive a copy of the Lienor's Notice as pravfded in Section 713.13(l)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expliallon date may not be before the completion of construction and final payment to the contractor,but will be one year from-the date of recording unless a different date is specified): WARNING•TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF'COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER713, PART 1, SECTION 713.13, FLORiDA STATUTES, AND CAN RESULT iN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT, Under penalty of perjury I declare that t have read the foregoing Lice commencement and that the fads stated therein are true to the best of my knowledge and be'tief. STATE OF FLORIDA COUNTY OF PASCO Stg Owner or Lessee,or Owner's or Lessee's Authorized Officer/Director/Partner/Manager ANIstant Secretary R. Horton Inc Signatory's Title/Office j The foregoing Instrument was acknowledged before me thist2±day of-A nLY 20& by as,Assistsrd Secrets Upe of authority,e.g.,oftloar,tust�ee,attorney in faoE for E) R Horton inc (nameofparty nbe elf f ham in Fm was executed). Personalty Known 1A0 Produced Iderrtifleation❑ Notary Signature G Type of Identification Produced Name(Print) NafAry Public Stain of Florida Ml COM Mayes My ComntiselonQG 057321 orwdf Er pIm 12(21*020 wpdatalbcslnoticecommencemenLpc053048 PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 17, BLOCK 19, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A AND 11B AS RECORDED IN PLAT BOOK 77, PAGE(S) 79-86, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LOT 3 I LOT 2 I LOT 1 BLOCK 19 BLOCK 19 BLOCK 19 S8959'20"E 50.00' ,�? I LOT 17 BLOCK 19 5.746 SO. FT f DRAINAGE TYPE A I z ' 1" = 30' 14 GRAPHIC SCALE (V 0 15 30 O I 1 0) � I •�:1o,�a I � A/C PAlIO:� '— ON LOT CALCULATIONS 6.0 LOT = 5.746 SO. FT. I 0 I LIVING AREA = 1,498 SO. FT. I moo' I x GARAGE = 385 SQ. FT. LOT 16 I 10 LOT 18 ENTRY = 17 SO. FT. BLOCK 19 i BLOCK 19 LANAI = 0 SO. Fr. I PROPOSED I PATIO = 80 SO. FT. Q l 0 4EWB I 3 DRIVEWAY = 360 SQ. FT. g FINISHED FLOOR � I p A/C PAD = 12 SQ. FT. p I ELEVATION-136.to' $ I o WALKWAY = 24 SO. FT. O I I IMPERVIOUS = 41% III III O = 2376 SQ. FT. O III III O SOD — 3,370 SQ. FT. Z VVVYYY I I IIIYYY O OFF LOT CALCULATIONS I COVERED I O RIGHT OF WAY = 900 SQ. FT. I c o I U) DRIVE APRON = 247 SO. FT. 6.0) 19.2' ;•: 'w 14.7 80, PUBLIC S/W - 250 SO. FT. I I SOD = 403 SO. FT. TOTALS' AREA - 6.646 SO. FT. DRIVEWAY =_607 SQ. FT. �' 1 .:.;.DRIVE"''` 10' PUE I SIDEWALK = 274 SQ. FT. SOD = 3,773 SQ. FT. lb g9 PC _ 392.50' _ I _42.50' ��` PST N8959'20'W 435.007(REFERENCE BEARING) \I—CENTERUNE OFRIGHT OF WAY BURMA REED DRIVE TRACT PREPARED FOR: 60' WIDE PRIVATEE RIGHT OF WAY 'AHa V& ". usy-'el BUILDING SETBACKS FRONT: 22, REAR: ' 13' SIDE: 5' (50' LOTS) 7.5' (55' & 60' WIDTH LOTS) SIDE STREET: 15' NOTES: 1. ELEVATIONS SHOWN ARE PER LOT GRADING PLANS PROVIDED BY THE CLIENT. LEGEND: 2. ELEVATIONS ARE BASED ON NAVD 1988 PI POINT OF INTERSECTION DATUM. — —•— BUILDING SETBACK LINE PC POINT OF CURVATURE 3. FOR ALL LOTS WHERE SIDE—YARD PT POINT OF TANGENCY SETBACKS ARE LESS THAN 7.50 FEET, A —-— CENTERUNE RP RADIUS POINT MINIMUM 5.00 FOOT WIDE DRAINAGE AND — --— RIGHT OF WAY LINE PRC POINT OF REVERSE CURVATURE ACCESS EASEMENT IS REQUIRED PER PASCO PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE COUNTY LAND DEVELOPMENT CODE. CS TYPICAL CONCRETE SLAB PROPOSED DRAINAGE FLOW (P) PER PLAT THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE 0 (C) CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PB PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PGs PAGES SQ. OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK F.E FT. SQUARE FEET .E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.I.R.M. FLOOD INSURANCE RATE MAP AND IS FOR INFORMATIONAL PURPOSES ONLY. NAVD NORTH AMERICAN VERTICAL DATUM NGVD NATIONAL GEODETIC VERTICAL DATUM THIS IS NOT A SURVEY D&UE DRAINAGE&UTILITY EASEMENT POE PRIVATE DRAINAGE EASEMENT THIS IS A PLOT PLAN ONLY PUE PUBLIC UTILITY EASEMENT D&AE DRAINAGE&ACCESS EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.RM. MAP N0. 121OICO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26.20 4.AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS 70 LIE IN ZONE'K', AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS"OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: LOCATED EXCEPT AS SHOWN. BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF BURMA A5hA 3. NOT VALID WITHOUT THE AUTHENTIC R®DRIVE BEING NB959'20'W,PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC A M E FR 1 CAN ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) REVISED: SURVEYOR AND MAPPP SURVEYING 90allysignedbylamesW ,srs'w eoleman SCALE: 1" 30 FEET yae°L DN:c=US,st=Florida,I=orlando, -& M A P P I N G INC. -AMERICAN SURVEYING& APPROVED BY: csau MAPPING,INC,cn=lamesW CERTIFICATION OF AUTHORIZATION NUMBER L FOR �'`+ 'n:m'F,t eoleman„ 18 LOT 17, 3191 MAGUIRE BOULEVARD, SUITE 200 "+ e'm'a0=)tolemanpasmm porace.co JOB No. BLOCK CK 19 ORLANDO, FLORIDA 32803 m THE Date:2020.0&03040426-G 00' FIRM PLOT DRAWN BY: PLAN WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM 6485 DAM 07 29 2020 JC D Q� iR Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2: Lots shall be graded:to.comply with R401.3 of the F.B.C. 3: Compaction test required if 24 or more of f ll.dirt is brought in at any one place. 4. Tie"in survey required before pouring concrete. 5. Driveways require a R.O.W.-use permit. All 4 sides of drive_ way thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 1. All property markers shall be uncovered and marked at time of first inspection. 8: All A.D.A.'requirements shall.be met: 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). 11. Appliances.shall not be installed in a location where subject to mechanical damage unless protected-by-approved barriers. M303 A of the F.B.0 12. Water-heaters shall comply with section P607.3 of the E.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.:1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C_. 16: All glazing requirement are to be in accordance with R308A of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum,board" shall not be used as a backer in showers or tubs:R7014.2 F.B.C. 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required iri new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C: 21. All plumbing,mechanical, and electrical shall be separate-from unit to unit. This includes all upderground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced: 21 Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code, lots shall be sodded before firial at least 10 feet around the structure: .25..R403.5.3Hot water pipe insulation Insulation-for hot water pipe With'a minimum thermal resistance (R-value) of R-3 shall be applied to the following: . . Piping.3/:inch (19.1 mm) and larger in.nominal diameter., Piping.serving more than_one dwelling unit. Piping located outside the conditioned space: Piping from the:water heater to a distribution manifold: Piping'located under a floor slab: Buried in piping, Supply and return piping in recirculation systems other than demand recirculation systems. 25.Blower door test shall be provided before C.O: 26. A cope of the energy cacls'shall be with permit at all tunes 27. Copt/of linaT insulation report shall be provided with perfnit before final 2.8. 1Vo fence,pool or'screen enclosure is issued with ihispermit F.F.E:-Finished Floor Elevation F.B.C-Florida Building Code 6a'Edition R.O.W.-Right of Way- A.D.A.=Americans with Disabilities Act N.E.C.-National Electric.Code (2016) . CITY OF " " BUILDING ZEPHYRHILLSNOTICE DEPARTMENT OF ADDITION OR CORRECTION . • NOT REMOVE ADDRESS DATE PERMIT# ,S(�33 Air M"LU k d 63 THIS JOB HAS NOT BEEN COMPLETED.The following additions or corrections shall be made before the job will be accepted. It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth or other material,until the proper inspector has had ample time to approve 780-0020 FO -1 N P CTI ON the installation. OFFICE HOURS 8:00 AM-4:30 PM MON.-FRI. INSPECTOR