HomeMy WebLinkAbout21-1307 a CI of Ze h rhills PERMIT NUMBER City p Y 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001307-2021 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 01/15/2021 Permit Type: Electric Service Replacement/Misc ProMyrty Number Street Address 35 25 210140 00900 0400 7811 Davie Ray Drive Owner Information Permit Information Contractor Information Name: JEREMY HALL TIFFANY SWANSOI` Permit Type:Electric Service Replacement/M Contractor: UNICITY SOLAR ENERGY Class of Work:Add/Alter Residential LLC Address: 7811 Davie Ray Drive Building Valuation:$0.00 ZEPHYRHILLS,FL 33541 Electrical Valuation:$24,325.00 Phone: (321)355-9454 Mechanical Valuation: Plumbing Valuation: Total Valuation:$24,325.00 Total Fees: 2 Amount Paid:d:$242.2.43 I Date Paid: 1/15/2021 1:26:11PM l I'rloject Description INSTALLATION ROOF MOUNT SOLAR SYSTEM Application Fees Electrical Plan Review Fee $80.81 Electrical Permit Fee $161.62 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT"EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780.0021 Building Department i Date Received Phone Contact for Permitting 727 637 _ 1450 ,aaaaaaaa aaaaa Owner's Name Jeremy Hall I Owner Phone Number (321)355-9454 Owner's Address 1 7811 Davie Ray Dr,Ze h rhills,FL 33540 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 7811 Davie Ray Dr,Zeph'rhilis,FL 33540 LOT# SUBDIVISION PARCELID# 35-2521-0140-00900-0400 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT 0 SIGN = = DEMOLISH INSTALL e REPAIR PROPOSED USE SFR Q COMM = OTHER TYPE OF CONSTRUCTION Q BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK RESIDENTIAL ROOF MOUNTED SOLAR PV SYSTEM BUILDING SIZE SQ FOOTAGE HEIGHT ca-ra- BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ 24,325 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION4 %I / =GAS = ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO O 1 �l� / L BUILDER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address I License# ELECTRICIAN COMPANY UNICITY SOLAR ENERGY, LLC SIGNATURE REGISTERED Y N FEE CURREN Y/N Address 612 FLORIDA AVE,PALM HARBOR,FL 34683 License# EC13008698 PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN I Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address I License# OTHER COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN I Y/N Address License# Etaaaal.aaala.aaaaa.aaa€€a.ease€.a.aaa.eases€aaaa€aaaaaa€€a.a_aa.a.a€€aaa_€€€.sit RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Farms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisionstlarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. -PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department i NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner,I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner prior to commencement CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER 0 A FO E RECORDING YOUR NOTICE MMENCEMENT- FLORIDA JURAT(F.S.117.03) OWNER OR AGENT "" CONTRACTOR Su d sworn to irtn efo`�j ers and sworn to(or a ed)bef r Su /�( V !� by Whc is/are personally known to me orhaslillave produced Wtfb is7are personally known to me or haslhavd produced as identification. as identification. Notary Public Notary Public Commi ' No._ commiss' o. Name of Notary typed,pdn d or stamped Name of Notary typed,printed or Mimped JORDAN KUJAT JORDAN KUJAT Notary Public,State of Florida Notary Public,State of Florida My Comm.Expires Jun.26,2023 My Comm.Expires Jun.26,2023 No.GG 348789 No.GG 348789 INSTR#2020186292 OR BK 10209 PG 2226 Page 1 of 1 11/03/2020 11:10 AM Rept:=748 Rec:10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk&Comptroller i Permit Number Parcel ID Number 35-25-21-0140- 900 Od00 NOTICE OF COMMENCEMENT State of Florida County of'Pi fry,—kl OAS THE UNDERSIGNED hereby gives notice that improvements vrill be made to certain real property,and In accordance with Section 713.13 of the Florida Statutes,the following information is prodded in this NOTICE OF COMMENCEMENT. 1.Description of property(legal description): ZEPHYR LAKES SUBDIVISION_PHASES 1A 2A 2B 8 4A PB 80 PG 37 BLOCK 9 LOT 40 a)Street(fob)Address: 7811 DAViE RAY DRIVE.ZEPHYRHILLS,FL 33541 2.General description of improvements: ROOF MOUNTED SOLAR PHOTOVOLTAIC INSTALLATION— 3.Owner information or lessee information if the Lessee contracted for the Improvement: a)Name and address: Jeremy Hall 7811 DAVIE RAY DRIVE,ZEPHYRHILLS._FL 33541 b)Name and address of fee simple tilleholder(if different than Owner listed above) c)Interest in property: OWNER 4.Contractor Information a)Name and address: UNICITY SOLAR ENERGY LLC- 612 Florida Ave Palm Harbor FL 34683 b)Telephone No.: 727-945-6060 __ _..._._._. Fax No.:(optional) _ _....... S.Surety(if applicable,a copy of the payment bond is attached) a)Name and address: b)Telephone No.: c)Amount of Bond: ti.Lender a)Name and address: b)Telephone No.: 7.Persons within the State of Florida designated by Owner upon uvhom notices or other documents may be served as provided by Section 713.13(1)(a)7.,Florida Statutes: a)Name and address: b)Telephone No.: _ Fax No.:(optional) 8.a.ln addition to himself or herself,Owner designates of to receive a copy of the LienDes Notice as provided in Section 713.13(1)(b),Florida Statutes. b)Phone Number of Person or entity designated by Owner. 9.Expiration date of notice of commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be I year from the date of recording,unless a different date is specified): ,20 _ WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR I PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN j ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. _._—j Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true-to the best of my knowled�a�Um r ( tgnawre of Owner or Lessee,or Owner's or Lessee's(Autlwri zed OHicer1DirettndPaMeriMana9er) (dnt Name and Provide Si natenfs Titiel0ffice) The foregoing instrument was acknowledged before me this __g _ day of U_ Ct0jag,,V^ 20 .20 _ by ^�� VNI t aam-u as `h nA.9 n XN"-- (type of authority,e.g.oftr.trustee,adomey in fact) (Nameof Person) (type of authoft...eg.officer,trustee,attorney In fact) for .r (j (name of patty on behalf of whom instrument was executed). Perso>laalfy_ ti. :.. , Produced.ID CRI . Typea;!.f iD _ � -- Notary Signature Print name OND HH�053166 Q` EXPIRES:QCSbbet 13 20lA - _ :�1 .•,�s,f;e. t3ondeAThiuNofaryl�EtYellndpYrrfUfs= � �` . . �1� I / Address: 78110avie.Ray or Zephyrhills,FL 33540 . System Size: 6.40 kW Unicity Panel Qty: 20 Solar Energy Site Assessment Elm A O 4 i� O a v"' PHOTOVOLTAIC MODULE GENERAL NOTES: INSTALLATION OF MODULES SHALL RUCTU LENGIDINROOFWINDZONE1AND2. WIND ZONE SERRATED 1-BOLT " Castillo ci 3 REQUIRES SITE SPECIFIC STRUCTURAL ENGINEERS APPROVAL. 1. APPLICABLE CODE: 2017 FLORIDA BUILDING CODE 6th ED.&ASCE 7-10 MINIMUM DESIGN I 1-SSSERRATED FLANGE NUT t Engineering LOADS FOR BUILDING AND OTHER STRUCTURES. 3 2 2 4'TYP. 3 L-FOOT WITH GROMMET 4.000 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2017 FLORIDA BUILDING DESIGNED TO PERMIT' CODE(6TH EDITION)REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHER 5/16'z 4"SS LAG BOLT YELLOW PINE(SYP)RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. WINS EPDM BONDED WASHER CASTILLO ENGINEERING 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL GABLE END BUILDING HIP END BUILDING 4' / SERVICES,LLC ROOFS,CONSIDERING FROM A 7"TO A MAXIMUM 27"(2/12 TO A MAXIMUM 6/12 PITCH)ROOF ROOF 2.375 COA#28345 IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOT EXCEED 30'-0"MEAN ROOF HEIGHT. ROOF WIND AREA 1 • 2.937 ZONES WIND AREA ZONES 00.375 2925 W.STATE ROAD 434, 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511,AND IS THE 1 2 \ SUITE 111 RESPONSIBILITY OF THE CONTRACTOR TO FILL ALL HOLES. i LONGWOOD,FL 32779 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURERS \ 8"FLASHING a.5sz MANUALS FOR ALL ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND SOLAR SPECS. ERMOCRA SLE4CASTILLO-FL PE 52590 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS 3 2 2 I I COPYRIGHTED BY OTHERWISE NOTED. I- -I 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. CASTILLO ENGINEERING 8. ALL 39"X 65"PV MODULES MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION O SERVICES,LLC DRAWING. 9. UNIRAC RACKING,PCM ATTACHMENTS,AND MODULES SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS. REVISIONS LiIID10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2017 FLORIDA BUILDING CODE(6TH ED)OR LOCAL GOVERNING CODE. 2 O �^ 12" O DESCRIPTION DATE REV __ fa i!D \ULTIMATE WIND EXPOSURE B WIND EXPOSURE C WIND EXPOSURE D EMBED. WIND MAX SPAN, MAX SPAN, MAX SPAN, DEPTH SPEED MAX CANTILEVER MAX CANTILEVER MAX CANTILEVER REQ. 3 2 2 3 2^ V"u(MPH) CONCRETE Le 3.00,5.00.OR 7.00 COMPOSITION " , PROJECT INSTALLER 110 6'-0"O.C.,1'-4"CTLVR 6'-0"O.C.,1'-4"CTLVR 4'-0"O.C.,1'-4"CTLVR 3" SHINGLE ROOF FINISH 120 6'-0"D.C.,1'-4"CTLVR 4'-0"O.C.,1'-4"CTLVR 4'-0"O.C.,1'-4"CTLVR 3"* TYPICAL PHOTOVOLTAIC ARRAY PITCHED ROOF LAYOUT-WIND ZONES-SCHEDULE-PLAN 130 6'-0"O.C.,1-4"CTLVR 4'-0"O.C.,1'-0"CTLVR 4'-0"O.C.,1'-4"CTLVR Y* SCALE: NONE G OCT c} 2020 14O 4'-0"O.C.,1'-4"CTLVR 4'-0"O.C.,1'-4"CTLVR 4'-0"O.C. 1'-4"CTLVR 3"* 1 0.250 CD 4 l 15O 4'-0"O.C.,1'-4"CTLVR 4'-0"O.C.,1'-4"CTLVR 2'-0"O.C.,l'-4"CTLVR** 3"* #10-16x1/2"ST STL SELF TAPPING SCREW TYP 4 160 4'-0"O.C.,1'-4"CTLVR 4'-0"O.C.,V-4"CTLVR Z-0"O.C.,1'4"CTLVR** 3"* PLCS PER BEAM SPLICE 12"ALUMINUM INTERNAL SPLICE BAR(USE WHEN SPLICE AT PCM FBS-AS L-FOOT 170 4'-0"O.C.,1'-4"CTLVR 2'-0"O.C.,1'-4"CTLVR 2'-0"O.C.,9"CTLVR** 3"" _ __ _. I MID-SPAN W/(4)#10-16X1/2"ST UNIRAC SM MOUNT L-FOOT gnature I STL SELF TAPPING SCREWS TYP AND FLASHKIT PRO SCHEDULE REFLECTS COMPONENTS AND CLADDING(C&C)NOMINAL WIND PRESSURES WITH EXPOSURE"B"-"C"-"D",RISK CATEGORY II,ENCLOSED BUILDING AND h<60-0"PER ASCE 7-10"MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES"AND 2017 F.B.C. PHOTOVOLTAIC UNIRAC STANDARD RAIL LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. TYPICAL SOLAR RAIL BEAM SPLICE DETAIL **3RD RAIL IS REQUIRED PER ROW OR COLUMN FOR SPECIFIED WIND SPEED AND EXPOSURE. SCALE: 1-1/2" l'-O" S_01 MODULE TYP. COMPOSITION SHINGLE ROOF OJECT NAME (DET OMITTED FOR CLARITY) CUT OUT OR REMOVE TILE TO INSTALL"ROOF 0- LL ATTACHMENT.RE-INSTALL,RE-FILL AND RE-SEAL TILES 3/8"-16 HEX CAP ST STL d AFFECTED WITH APPROVED ROOF MATERIALS BOLT AND ST STL SERRATED Q 0 USE ANTI-SEIZE AND TIGHTEN TO PHOTOVOLTAIC O MODULE TYP. FLANGE NUT TYP. ` TORQUE PER MANUF.INSTRUCTIONS GROUNDING , U) LLU 3/8"-16 HEX CAP ST STL MID/END CLAMP III Z = BOLT AND ST STL SERRATED APPLY A GENEROUS AMOUNT O U FLANGE NUT TYP. OF MIAMI-DADE NOA APPROVED 0 0- ROOF SEALANT/CEMENT PRIOR UNIRAC; UJ GROUNDING TO A RAIL ATTACHMENT INSTALL STANDARD RAIL] z 0 IMID/END CLAMP COVERING AREA SIMILAR IN I l UNIRAC STANDARD SIZE TO THE ATTACHMENT,FILL UNIRAC 0 } S.Y.P.2X4 SPANNER LOCATE BETWEEN TRUSSES AND PCM FBS-AS CUT TILE CAVITY COMPLETELY FASHKIT J NAIL WITH 2-16D NAIL 3",5",or 7"L-Foot , AND SMOOTH TO TILE CONTOUR FLASHING Q < � Q PATTERN AT EACH END TO -�' WOOD TRUSS WOOD ROOF W �����,HF+�.�^ +��EVAILI TRUSS TYP._ (1)5/16"ST STL LAG BOLT- 0 � AL Q A- ,IAA But-C)i3 G GLIDE' Q' P- "� � NAtMXLFEl` cTp'Ic GCODE - WOOD SEE SCH FOR EMBED �t�YR s SHEATHING DEPTH REQUIRED " PND THE CI"Ty OF CUT TILE,COMPLETELY C �� �y 4A1�5� 0. SHEET NAME OLT- STRUCTURAL FILL CAVITY AND � (2)5/16"ST ST'L'' B a� '{ CONTOUR WITH SEE SCH FOR EMBED JlQI� 321 ATTACHMENT CEMENT r WOOD DEPTH REQ-RE�/IEUV DATE POSITION SHINGLE SHEATHINGZEPHYR ROOF FINISH CONNECTION DETAIL DETAILS FLAT OR BARREL CITY OF I�� SCALE: 1-1/2"=1'-0" ANSI B S-01 SHEET SIZE BLOCKING FOR MISSED ROOF TILES 4"X4"TRUSS SPANNER OR M h+ TYP. PLAN EXA TRUSS ATTACHMENT (IF REQUIRED) I I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE 11'E X 17" CONC TILE CONNECTION DETAIL 4 WITH FBC:BUILDING CHAPTER 16 AND FBC:RESIDENTIAL CHAPTER 3. SHEET NUMBER ' - SCALE: 1-1/2"=1'-0" BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND MISSED TRUSS CONNECTION DETAIL , S-01 SCALE: 1-1/2"=1'-0" S-01 LATERAL AND UPLIFT FORCES,AND EQUIPMENT DEAD LOADS. S-01 SOLAR ARRAY 6.400 KW-DC SIC) Cast jib O U ❑ Engineering_ Y (20)HANWA:HANWHA Q.PE_AK DUO BLK-G5(320W) J _- _ DESIGNED TO PERMIT• ti9ODULES 320 � - - - - - - _ I . (O2)BRANCHES OF 10 MODULES CA:iTILLO ENGINEERING _ - SERVICES,LLC COA M 29345 NOTE: 620 N.WYMORE ROAD, Q CABLES 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE SUITE 250, ❑ Q -I ❑ p ❑ ❑ ] 0 REQUIREMENTS OF THE NEC 2014,AND THOSE SET FORTH BY MAITLAND,FL 32751 1 n {;= ice = THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, ERMOCRA TEL:(407)289-2575 TES E.CASTILLO•FL PE 52590 - . INCLUDING MAXIMUM NUMBER OF MODULE STRINGS,MAXIMUM COPYRIGHTED BY . - - - - -- - - - - - - - - - - - NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, CASTILLO ENGINEERING MODULE MANUFACTURER AND MODEL NUMBER, INVERTER SERVICES,LLC MANUFACTURER AND MODEL NUMBER,AS APPLICABLE. ENPHASE IQ7-60-2-US 2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL REVISIONS MICROINVERTERS GUTTER SPACE IS INADEQUATE. PV MODULES 3. DOWNSTREAM PANEL FROM LOAD TAP TO BE PROTECTED DESCRIPTION DATE REV Y8 3PRE-EXISTING OR ADDITIONAL OCPD AS NEEDED PER NEC B PROJECT DEVELOPER INTERCONNECTION ' 120%RULE-NEC 7O5.12(D)(2)(3)(b) r UniCity 1, UTILITY FEED+SOLAR BACKFEED >��� Solar Energy 150A+30A=180A BUSS RATING x 120% TO UTILITY GRID si9°'(Ufel I ipta I si n 200A x 120%=240A 9 y 9 _ by Ermocrate L1 IL2I 1 N =' E Cdstlllo BI-DIRECTIONAL UTILITY M5TER F Date: 1-PHASE,240V 1__ J I i- 2020.11.02 N SOLADECK - 11:17:19 _ QO ( ) L1 L2 N PROJECT NAME 600 V,NEMA 3R (N)AC DISCONNECT: (E)MAIN BREAKER UL LISTED I (N)125A ENPHASE IQ COMBINER 3 240V,60AMP RATED, 150A/2P,240V I T I -- TO BE (X-IQ-AM1-240-3)[WITH UPTO(4) NEMA 3R,UL LISTED, L1 L2 N PROTECTED BY -'-2 `�I L1 2-POLE BREAKERS AND ENVOY LOCKABLE&FUSIBLE, PRE-EXISTING COMMUNICATION GATEWAY] WITH 30A FUSES dCPD ASIONAL Gi 1L2' Lt .. Lt REQUIRED L1 L1 L1 1l_-(• - M L2 L2 • L2 j 7 z �' J 2 10/2 ROMEX RUN IN ATTIC N N I LIJ Q U- ( ) LN I OR - - - - -•- - - (2)#10 AWG THWN-2-RED G L1 (2)#10 AWG THWN-2-BLACK - L2 L2 Li j LJ.I J I - (1)#10 AWG THWN-2 GND L1 L1 I L1 -L1 QQ IN 3/4"IMC,RMC,FMC,LFMC, _ PVC,HOPE,NUCC,RTRC, L2 ,L2 L2 - L2 I (3)#6 AWG THWN-2 I _ _ LFNC,EMT,FMT OR ENT (1)#10 AWG THWN-2 GND ] L1 �, L1 J _3/4"VC, CONDUIT RUN IN PIHDPE NUCC RTRCC I L1- -f[ _ _ LFNC,FMT,ENT OR EMT L2 L2 L2 L2 CONDUIT RUN - N aCWJ LOAD TAP USING FEEDER - LUGS ORINSULATION N I 200A RATED,240V. SHEET NAME PIERCING PER NEC 705.12(B) L__ - - - G EXISTING WIRE ELECTRICAL LINE DIAGRAM 2OAl2P (E)MAIN DISTRIBUTION L1� -1 PANEL,200A RATED,240V SHEET SIZE - - L2 ANSI B L�oAl2P' EXISTING GROUNDING 11 X 17" 121— j ELECTRODE SYSTEM I 1 ELECTRICAL LINE DIAGRAM P SHEET NUMBER N G E-01 SCALE: NTS E-01 AC CONDUCTOR AMPACITY CALCULATIONS: AC CONDUCTOR AMPACITY CALCULATIONS: Castillo(FROM ROOF TOP SOLADECK TO LOAD CENTER FROM AC COMBINER BOX TO MSP EngineeringDESIGNED TO PERMIT. CASTILLO ENGINEERING MODULE PROPERTIES SERVICES,LLC MODULE MANUFACTURER HANWHA VOC 40.56 IBC 9.94 COA#28345 E MODULE_MODEL q.PEAK DUO BLK-G5 32a - - ELECTRICAL NOTES 620 N.WYMOREROAD, PHASE VMP. 33.8 IMP 9.47 SUITE 250, INVERTER MANUFACTURER MAITLAND,FL 32751 ENPHASE IQ 7 TO VDc -0.27%!'K TO VMP -0.36g4/`K 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND TELI(407)269-2575 INVERTER MODEL ERMOCRATES E.CASTILLO-FL PE52590 MODULES/BRANCH CIRCUIT 1 1 O PMP 320.0 NOCT 45 °C LABELED FOR ITS APPLICATION. 1 0 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 COPYRIGHTED BY MODULES/BRANCH CIRCUIT 2 CASTILLO ENGINEERING TOTAL ARRAY POWER (KW) 6.40H DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR SERVICES,LLC SYSTEM AC VOLTAGE 240V 1-PHASE 75 DEGREES C. INVERTER PROPERTIES DESIGN TEMPERATURE. r PUT VOLTAGE 240 L-L I-PH 3. THE WIRES ARE SIZED ACCORDING TO NEC. 110.14 . REVISIONS 4 WIRING, CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS DESCRIPTION DATE REV MIN. AMBIENT TEMP. 'F a2 INPUT DC VOLTAGE 4e VDC SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS RATING RANGE 1 6 • 46 vOC POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. MAX. AMBIENT TEMP. 'F 1 1 7 PT VOLTAGE RANGE 27 - 37 Von 5, WORKING CLEARANCES AROUND ALL NEW AND EXISTING CALCULATED MAX. VOC CONDUIT FILL MAX INPUT POWER 350 22 VDC `7 START VOLTAGE ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. CALCULATED MIN VMP ��_ _ WDC 6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTINUOUH AC POWER 240 VA CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, NUMBER OF CONDUITS SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE PROJECT DEVELOPER AMPACITY CALCULTIONS CODES AND STANDARDS. 90 'C AMBIENT TEMP CONDUIT FILL DEBATED MAXIMUM CIRCUIT 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS fJ,�► u���� •L� S .25 X AWG /( CIRCUIT MAX AMPS ARE NOT SPECIFIED,THE CONTRACTOR SHALL SIZE THEM ` MAX AMPS AMPACITY TEMP �F DEBATE FILL DEBATE AMPACITY BREAKER Uri Energy ACCORDINGLY. Sater 4 ❑•B z❑ A 8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED CIRCUIT 1 1 0.0 12.5 #10 40 1 30 0.76 3 AND READILY VISIBLE. SI9rIE urawl ETa CIRCUIT 2 1 0.O #,❑ 40 1 3D 0.76 a 0 B z° A 9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE signed by AC COMBINER 20 O __._ #B ss 9s O 46 a 1 - - ;°. FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP , w Ermocrates PANEL OUTPUT MANUFACTURER'S INSTRUCTION. _r Castillo 10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER " }s Date: 1s;`... G.E.C.VIA WEER LUG OR ILSCO GBL-4DBT LAY-IN LUG. 2020.11.02 MAXIMUM CIRCUIT VOLTAGE DROP 2% 11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE . 11:17:25 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL _- PROJEC VOLT GE DROP CALCULATIONS PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE th CIRCULAR MAX I_ ENTRANCE. CIRCUIT AwG MILLS I V LENGTH 13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. CIRCUIT 1 #10 1 0380 1❑.0 Sa.D 14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. LLJ dam' CIRCUIT 2 #10 1038❑ 10.0 244 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS U LO � M COMBINER PANEL OUTPUT #a 16510 20.0 240 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6(C)(1)AND ARTICLE z p (� 310.10 (D). >' J 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE LL FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10(C). O W (n NOTES TEMP DEBATE BASED ON NEC TABLE 31 O.1 S(B)(2)(A) -- -- J CONDUIT FILL DEBATE BASED ON NEC TABLE 31 0.1 5(B)(3)(A) � Jy MODULE MANUFACTURE TEMPERATURE COEFFICIENTS PER NEC 690.7(A) ENPHASE IQ7-60-2-US MICROINVERTER W p it MAXIMUM VOC CALCULATED U91NG Input Data(DC) UNLESS OTHERWISE SPECIFIED, ALL WIRING MUST BE THHN OR THWN-2 COPPER J O ALL WIRE SIZES LISTED ARE THE MINIMUM ALLOWABLE Recommended Input Power($TC) 235-350W+ —J a IN ANY CELL INDICATES THAT THE SYSTEM IS SAFE AND COMPLIES WITH NEC REQUIREMENTS Maximum Input DC Voltage 48V = ~ N IN ANY CELL. INDICATES A POTENTIALLY UNSAFE CONDITION Peak Power Tracking Voltage 27V-37V INFORMATION INPUT BY SYSTEM DESIGNER Operating Range 16V-4 INFORMATON OBTAINED FROM MANUFACTURER DATASHEETB Min./Max. Start Voltage 22V/48V Max DC Short Circuit Current 15A SHEET NAME Output Data(AC) WIRING Maximum Output Power 240W CALCULATIONS I ERMOCRATES CASTILLO PE# 52590 AN ENGINEER Nominal Output Current 1.0A SHEET SIZE LICENSED PURSUANT TO CHAPTER 471, CERTIFY Nominal Voltage/Range 240W211-264V THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL ANSI B COMPONENTS ARE DESIGNED AND APPROVED USING Nominal Frequency!Range 60 Hz 1 111 X 1711 THE STANDARDS CONTAINED IN THE MOST RECENT Extended Frequency/Range 47-68 Hz VERSION OF THE FLORIDA BUILDING CODE. FBC 107. Power Factor at rated power 1.0 SHEET NUMBER Maximum unit per 20A Branch Circuit 16(240 VAC) E-02 INSTALLATION OF MODULES SHALL BE LOCATED IN ROOF WIND ZONE 1 AND 2. WIND ZONE SS SERRATED T-BOLT Castillo PHOTOVOLTAIC MODULE GENERAL NOTES: 3 REQUIRES SITE SPECIFIC STRUCTURAL ENGINEERS APPROVAL. SS SERRATED FLANGE NUT Engineering 1. APPLICABLE CODE: 2017 FLORIDA BUILDING CODE 6th ED.&ASCE 7-10 MINIMUM DESIGN ... LOADS FOR BUILDING AND OTHER STRUCTURES. 3 2 4'TYP. 3 L-FOOT WrrH GROMMET 4.000 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2017 FLORIDA BUILDING oesIGHeo TO PSIN n CODE(6TH EDITION)REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHER 5/16"xa"SS LAG BOLTT CASTILLD ENGINEERING YELLOW PINE(SYP)RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. w/ss EPDM soNDED WASHER 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL GABLE END BUILDING HIP END BUILDING O P. _ SERVICES, LLC ROOFS,CONSIDERING FROM A 7°TO A MAXIMUM 27°(2/12 TO A MAXIMUM 6/12 PITCH)ROOF ROOF WIND AREA ROOF 2.375 conttzeaas 00.37 2.937 2925 W.STATE ROAD 434, IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOT EXCEED 30'-0"MEAN ROOF HEIGHT. ZONES WIND AREA ZONES O 2 ��� 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511,AND IS THE SUITE 111 RESPONSIBILITY OF THE CONTRACTOR TO FILL ALL HOLES. 0.562 LONGWoo)2 FL 32779 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURERS 8"FLASHING TEL:.CA)TILLO- MANUALS FOR ALL ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND SOLAR SPECS. ERMOCRATES E.CASTILLD•FL PE 52590 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS 3 2 COPYRIGHTED BY OTHERVSE NOTED. --z.0000— FCASTILLO ENGINEERING 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. 3 2i -mom SERVICES,LLC 8. ALL 39"X 65"PV MODULES MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION -_ DRAWING. 9. UNIRAC RACKING,PCM ATTACHMENTS,AND MODULES SHALL BE INSTALLED PER REVISIONS MANUFACTURERS INSTRUCTIONS. 10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED 2 - 1z., DESCRIPTION DATE REV PER 2017 FLORIDA BUILDING CODE(6TH ED)OR LOCAL GOVERNING CODE. O 1��" I ULTIMATE WIND EXPOSURE B WIND EXPOSURE C WIND EXPOSURE D EMBED. WIND MAX SPAN, MAX SPAN, MAX SPAN, DEPTH 2 J - 3 1 _El SPEED MAX CANTILEVER MAX CANTILEVER MAX CANTILEVER REQ. - - r�"- 3.00,5.00.OR 7.00 V°il(MPH) CONCRETE TILE OR COMPOSITION -s " PROJECT INSTALLER 110 6'-0"O.C.,1'-4"CTLVR 6'-0"O.C.,1'-4"CTLVR 4'-0"O.C.,1'-4"CTLVR 3"* SHINGLE ROOF FINISH "" TYPICAL PHOTOVOLTAIC ARRAY PITCHED ROOF O ,`` w m 120 6'-0"D.C.,1'4"CTLVR 4'-0"O.C. 1'4"CTLVR 4'-0"O.C. 1'4"CTLVR 3"* ,•...... `O s�banr� LAYOUT-WIND ZONES-SCHEDULE-PLAN •, ! 1 ,52gf,•., 5*10 1 130 6'-0"O.C.,1'4"CTLVR 4'-0"O.C.,1'-4"CTLVR 4'-0"O.C.,1'-4"CTLVR 3"* \S-0') M1 'No. TA 2590'. SCALE: NONE [ ` R STATE OF ', ,ne**ofmi5E°,menl nd o.zso O `..F w 140 4'-0"O.C.,1'-4"CTLVR 4'-0"O.C.,1'-4"CTLVR 4'-0"O.C.,1'-4"CTLVR 3" Jmwna am°*n° *• * #10-16x1/2"ST STL SELF 4 c .'s "� s 150 4'-0"D.C.,1'-4"CTLVR 4'-0"O.C.,1'-4"CTLVR 2'-0"O.C. 1'-4"CTLVR 3"* TAPPING SCREW TYP 4 12"ALUMINUM INTERNAL SPLICE L 160 N-0"O.C.,T-4"CTLVR 4'-0"D.C.,1'-4"CTLVR Z-O"D.C.,1'-4"CTLVR 3"* PLCS PER BEAM SPLICE BAR(USE WHEN SPLICE AT " POM FBS-AS L-FOOT S are wh. Seal 170 4'-O"O.C.,1'-0"CTLVR 2'-0"O.C.,1'a"CTLVR 2'-0"O.C.,9"CTLVR 0° 3"" �-__ MID-SPAN W/(4)#10-16X112"ST UNIRAC SM MOUNT L-FOOT to s I n ed `�- STL SELF TAPPING SCREWS TYP AND FLASHKIT PRO g y -SCHEDULE REFLECTS COMPONENTS AND CLADDING(C&C)NOMINAL WIND PRE SSURES mocrates E WITH EXPOSURE"B"-"C"-"D",RISK CATEGORY 11,ENCLOSED BUILDING AND h<60'-0"PER ASCE 7-10"MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES"AND 2017 F.B.C. UNIRAC STANDARD RAIL aStIIIO *LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. TYPICAL SOLAR RAIL BEAM SPLICE DETAIL Z PHOTOVOLTAIC **3RD RAIL IS REQUIRED PER ROW OR COLUMN FOR SPECIFIED WIND SPEED AND EXPOSURE. SCALE: 1-1/2"=1'-0' S-Q1 MODULE TYP. ate. 2020.10.29 COMPOSITION SHINGLE ROOF :S nP5Fpd�CT�12V0o1 (DET OMITTED FOR CLARITY) > lJL V CUT OUT OR REMOVE TILE TO INSTALL"ROOF 3/8"-16 HEX CAP ST STL n'• O ATTACHMENT.RE-INSTALL,RE-FILL AND RE-SEAL TILES BOLT AND ST STL SERRATED Q AFFECTED WITH APPROVED ROOF MATERIALS PHOTOVOLTAIC 0 FLANGE NUT TYP. LL USE ANTI-SEIZE AND TIGHTEN TO MODULE TYP. TORQUE PER MANUF.INSTRUCTIONS GROUNDING Z = 3/8"-16 HEX CAP ST STL MID/END CLAMP A Z = O -f- BOLT AND ST STL SERRATED ' APPLY GENEROUS AMOUNT OF MIAMI-DADS NOA APPROVED = �f FLANGE NUT TYP. ROOF SEALANT/CEMENT PRIOR UNIRAC - U GROUNDING STANDARD RAIL °� Z O TO ATTACHMENT INSTALL z Z >,M MID/END CLAMP COVERING AREA SIMILAR IN UNIRAC Q C LL UNIRAC STANDARD RAIL A SIZE TO THE ATTACHMENT,FILL Q S.Y.P.2X4 SPANNER I OCATE ° CUT TILE CAVITY COMPLETELY FASHKIT -i . BETWEEN TRUSSES AND PCM FBS-AS AND SMOOTH TO TILE CONTOUR FLASHING NAIL WITH 2-16D NAIL 3",5",or 7"L-Foot „4 `� ` WOOD ROOF w N PATTERN AT EACH END TO ` TRUSS TYP. O '-'- -- r WOOD TRUSS i� - -_ (1)5/16"ST STL LAG BOLT- Q (o 00 N / WOOD ROOF WOOD SEE SCH FOR EMBED _ N �c DEPTH REQUIRED TRUSS TYP. -- I _ =f � SHEATHING ��� �� SHEET NAME CUT TILE,COMPLETELY- (2)5/16"ST STL LAG BOLT- STRUCTURAL FILL CAVITY AND a o!_�' SEE SCH FOR EMBED ATTACHMENT CONTOUR WITH _ _ COMPOSITION SHINGLE CEMENT WOOD DEPTH REQ. ROOF FINISH CONNECTION DETAIL 5 DETAILS SHEATHING } SCALE: 1-112"=1'-0" S-01 SHEET SIZE 4"X4"TRUSS SPANNER OR tit FLAT OR BARREL BLOCKING FOR MISSED ROOF TILES TYP ANSI B j�- TRUSS ATTACHMENT (IF REQUIRED) I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE 11" X 17" CONC TILE CONNECTION DETAIL WITH FBC:BUILDING CHAPTER 16 AND FBC:RESIDENTIAL CHAPTER 3. SHEET NUMBER SCALE: 1-1/2"=l'-0" S-01, BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND MISSED TRUSS CONNECTION DETAIL LATERAL AND UPLIFT FORCES,AND EQUIPMENT DEAD LOADS. S-O 1 SCALE: 1-1/2" 1'-0" (1) -Q Castillo Engineering DESIGNED TO PERM ITa CASTILLO ENGINEERING SERVICES,LLC COO#28345 620 N.VVYMORE ROAD, powered by 1 —_ c SUITE 250, DLBD Format 66.3in x 39.4in x 1.261n(including frame) ,__ - SUITE ND, 5L 32751 (1685mm x 1000mm x 32mm) TEL,(407)209-2575 4 ERMOCRATES E.CASTILLO-FL PE 52580 Weight 41.21bs(18.7 kg) From Cover 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology y, COPYRIGHTED BY CASTILLO ENGINEERING Back Cover Composite film i SERVICES,LLC Frame Black anodized aluminum �4+ Call 6 x 20 monocrystalline Q.ANTUM solar half-cells ❑ "°� REVISIONS Junction box 2.76-3.35i0 1<1.97-2.76 in x 0.51-0.83 in ,,,,,,,,,, (70-85mm x 50-70mm x 13-21 mm),decentralized,IP67 + ' ^*d10"L"' + DESCRIPTION DATE REV Cable 4mm'Solar cable;1+)x43.3in(1100mm),(—)≥43.3i0(1100mm) 1�rxeww ,,,,, Connector Multi-Contact MC4,(P68 DUO 300-P-3201 POWER CLASS 300 305 3)0 315 320 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/—OW) Power at MPP' PPP, [WI 300 305 310 315 320 Short Circuit Current' I,, [Al 9.72 9.78 9.83 9.89 9.94 PROJECT DEVELOPER eY IV] 39.48 39.75 40.02 40.29 40.56 L ' l ' e Open Circuit Voltage' °c Current at MPP l,, [Al 9.25 9.31 9.36 9.41 9.47 lJnicity Voltage at MPP V,, [VI 32.43 32.78 33.12 33.46 33.80 The new Q.PEAK F11 r3!?`t solar module from Q CELLS impresses with Efficiency' n [%] 217.8 218.1 218.4 ≥18.7 219.0 ,�,j Solar Energy its outstanding visual appearance and particularly high performance MINIMUM PERFORMANCE AT NORMAL OPERATIND CONDITIONS,NMOr W] 224.1 227.8 231.6 235.3 239.1 on a small surface thanks to the innovative ., Power at MPP Parr [:AANTU.'r Technology.UNTUM's world-record-holding cell concept has now been combined Short Circuit Cument le (Al 7.83 7.88 7.92 7.97 8.01 Signature with Seal E Open Circuit Voltage l e [V] 37.15 37.40 37.66 37.91 38.17 with state-of-the-art circuitry half cells and a six-busbar design, thus g Current at MPP I,,,PP [Al 7.28 7.32 7.37 7.41 7.45 achieving outstanding performance under real conditions --• both with Voltage at MPP Vp,P [V) 30.78 31.11 31.44 31.76 32.08 low-intensity solar radiation as well as on hot, clear summer days. 'Measurement tolerances P,a v3%;Ix,Vuvs5%at sic,100000/mr,25s2°C,AM 1.50 according to IEC 60904-3-'800 WueC,NMOT,spectrum AM 1,50 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE Q Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY °,E,r, At least er m of nominal power during first yeas ° PROJECT NAME classes,and an efficiency rate of up to 19.3%. • `-"°"'"°'"'""'"""'"""" Thereafter moo.0.54%degradation per year. Higher yield per surface area, lower BOS costs,higher power - At least 93.1%of nominal power up to 10 years. Im At least 85%of nominal power up to 25 years. pf All data within measurement tolerances. INNOVATIVE ALL-WEATHER TECHNOLOGY ® Full warranties in accordance with the warranty 8 terms of your Q CELLS sales organization of your p Optimal yields,whatever the weather with excellent low-light ¢¢ _ respective country. ax .°P p r r '° IRRADIANCE rwAsv rJ r and temperature behavior. LL co u , nazis Typical module performance under low irradiance conditions in Q C) ENDURING HIGH PERFORMANCE p comparison to STC conditions 125°c,100000/m'). Cb Z Long-term yield security with Anti LID Technology, � CELLS o } J m°ucw° TEMPERATURE COEFFICIENTS Anti PID Technology', Hot-Spot Protect and Traceable Quality Tra.QTM- TIi x,2018• Temperature Coefficient oflu a 1%/Kl +0.04 Temperature Coefficient of V,0 p [%/K] —0.28 _ Temperature Coefficient at P0,, v [%/Kl —0.37 Normal Operating Module Temperature NMOT [°F] 109±5.4(43 t3°C) EXTREME WEATHER RATING Q (/) W J ' High-tech aluminum alloy frame,certified for high snow f' "'' o W > 2 (5400 Pa)and wind loads(4000 Pa)regarding IEC. Maximum system Voltage V,,1 [VI 1000(1 LC)11007(UL) Safety class u a O ry Maximum Series Fuse Rating [A DC] 20 Fire Rating C(IEC)/TYPE 1(UL) d J A RELIABLE INVESTMENT 113(5400 Pa)/84( on cont Max.Design Load,Push/Pull lUL)s [Ibs/N'l 75(3600 Pa)/55(2667 Pal Permitted module temperature —40°F up to+185°F continuous duty (-40°C up to+85'C) a Q Inclusive 12-year product warranty and 25 year a+arlty r°at°dinstallationW W .ewr linear performance guarantee Max.Test Load,Push/Pull(UU' (160181 113 Pa) s see manual 2. *+... N STATE OF THE ART MODULE TECHNOLOGY 14D 0032587 UL 1703;VDE Quality Tested;CE-compliant; Number of Modules per Pallet 32 Q.ANTUM DUO combines cutting edge cell separation IEC 61215:2016;IEC 61730:2016,Application class A Number of Pallets per 53'Trailer 30 and innovative wiring with Q.ANTUM Technology. ' APT test conditions according to C Aw Number at Pallets per High Cube Container 26 IEC/TS 62804-1:2015, pVE method 8(-1500 V,168h) Pallet Dimensions(L x W x Hl 69.3 in x 45.3 in x 46.9 in SHEET NAME c ur (1760mm x 1)5Omm x 1190mm) ' See data sheet on rear for further °" " MODULE information. Pallet Weigle 14151b5(642 kg) THE IDEAL: N FOR: DATA SHEET NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. — Rooftop areas c.l residential buildings Hanwha 4 CELLS America Inc. 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA 1 +1 949 748 59 96 1 inquiry®us.q-cells.com I WEB www.gtells.us SHEET SIZE OCELLS ANSI B1 Engineered in Germany 1" X 17" SHEET NUMBER DS-01 Castillo Engineering DESIGNED TO PERMIT- CASTILLO ENGINEERING SERVICES,LLC COA#28345 Enphase IQ Combiner 3 620 N.WYMORE ROAD, SUITE 250, MAITLAND,FL 32751 Enphase Networking MODEL NUMBER _ -- _ -T TEL(407)255-2575 ERMOCRATES E.CASTILLO-FL PE 52590 IQ Combiner 3 X-IQ-AM1-240-3 10 Combiner 3 with Enphase IQ Envoy'"printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2 5%). COPYRIGHTED BY ACCESSORIES and REPLACEMENT PARTS(not included,order separately) CASTILLO ENGINEERING �_ SERVICES,LLC Enphase Mobile Connect'" CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 REVISIONS CELLMODEM-01(3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1(40 based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) DESCRIPTION DATE REV Enphase The Enphase IQ Combiner 3'"with Enphase Consumption Monitoring*CT CT-200-SPLIT Split core current transformers enable whole home consumption metering(+/-2.5%). IQ Envoy consolidates interconnection Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. IQ Combiner 3 BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 equipment into a single enclosure and BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 (X-IQ-AM1-240-3) streamlines PV and storage installations by EPLC-01 Power line carrier(communication bridge pair),quantity 2 providing a consistent,pre-wired solution for XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) PROJECT DEVELOPER residential applications. It offers up to four XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS _ '^ unICI't'L 2-pole input circuits and Eaton BR series Rating Continuous duty ( Solar Energy busbar assembly. System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Signature with Seal Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.continuous current rating(input from PV) 64 A Max.total branch circuit brehker rating(input) 80A of dl9tributed generation/90A with IQ Envoy breaker included Smart Production Metering CT 200 A sblld core pre-installed and wired to if Envoy Includes IQ Envoy for communication MECHANICAL DATA T �_.. and controlPROJECT NAME _ Dimensions(WxHxD) 49.5 x 37.5 x 16.8 dm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). Flexible networking supports Wi-Fl, Weight 7.5 kg(16.51bs) ii Ethernet,or cellular Optional AC receptacle available for PLC Ambient temperature range -40°C to+46°C'(-40°toll 5°F) bridge Cooling Natural conv9dtlotl,plus heat shield 't Provides production metering and optional Enclosure environmental rating Outdoor,NRT[certified,NEMA type 3R,polycarbonate construction f , M consumption monitoring Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG Copper conductors z 60 A breaker branch input: 4 to 1/0 AWG copper conductors >_ J Main lug combined output: 10 to 2/0 AWO copper conductors Q Neutral and ground: 14to 1/0 copper conductors Simple Always follow local code requirements for conductor sizing. • Reduced size from previous combiner Altitude To 2000 meters(6,560 feet) W J • Centered mounting brackets support single INTERNET CONNECTION OPTIONS T T — _. W Q = stud mounting Integrated WI-FI 80211b/g/n O D • Supports back and side conduit entry Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) J J — = _ . ^ Up to four 2-pole branch circuits for 240 VAC Cellular Optional,CELLMODEM-01(3G)or CELLMODEM-03(4G) or CELLMODEM-M1(4G based LTE-M) Q 00 a- r� plug-in breakers(not included) (not included) _ ~ N • • 80 Atotal PV or storage branch circuits COMPLIANCE Compliance,Combiner UL 1741 CAN/CSA C22.2 No.107.1 Reliable 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12 20 accuracy class 0.5(PV production) • Durable NRTL-certified NEMA type Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 SHEET NAME 3R enclosure *Consumption monitoring is required for Enphase Storage Systems. COMBINER BOX • • Five-year warranty w L • ULlisted DATA SHEET To learn more about Enphase offerings,visit enphase.com /� LISTED E N P HA SE. 0 2018 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. e E N PHASE. SHEET SIZE To learn more about Enphase offerings,visit enphase.com 2018-09.13 ANSI B 11EE X 17" SHEET NUMBER DS-03 Castillo Engineering DESIGNS° 70 PERMITH CASTILLO ENGINEERING SERVICES,LLC COA v 28345 620 N.WYMORE ROAD, Data Enphase IQ 7 and IQ 7+ Microinverters SUITE 250, MAITLAND,FL 32751 Enphase Microinverters CASTILLO Region: INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US F�r ERMOCRATES E. .2575 75 TEL: PE 52590 Commonly used module pairings' 235 W-350W+ 235W-440W+ COPYRIGHTED BY Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules CASTILLO ENGINEERING Maximum input DC voltage 48 V 60 V SERVICES,LLC Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16V-48V 16 V-60 V REVISIONS DESCRIPTION DATE REV The high-powered smart grid-ready Min/Max start voltage 22V/48V 22V/60V Enphase Enphase IQ 7 Micro'"and Enphase IQ 7+Micro"" Max DC short circuit current(module lsc) 15 A 15 A Overvoltage class DC port II II !Q 7 and IQ 7+ dramatically simplify the installation process while DC port backfeed current 0 A 0 A achieving the highest system efficiency. PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit Microinverters Part of the Enphase IQ System,the IQ 7 and OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter IQ 7+Microinverters integrate seamlessly with Peak output power 250 VA 295 VA PROJECT DEVELOPER the Enphase IQ Envoy'",Enphase Q Aggregator' Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V/ Enphase IQ Battery ,and the Enphase Enlighten'" 211-264V 183-229V 211-264V 183229V p;:S, UnicitlJ monitoring and analysis software. Maximum continuous output current 1.0 A 1.15 A 1.21 A 1.39 A Enorgy Nominal frequency 60 Hz 60 Hz IQ Series Microinverters extend the reliability Extended frequency range 47.68 Hz 47-68 Hz standards set forth by previous generations and AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Signature with Seal Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(240 VAC) undergo over a million hours of power-on testing, 13(208 VAC) 11(208 VAC) enabling Enphase to provide an industry-leading overvoltage class AC port III III warranty of up to 25 years. AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% PROJECT NAME Easy to Install CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA IQ 7 Microinverter Lightweight and simple Ambient temperature range -40°C to+66°C �r...• a A�v • Faster installation with improved,lighter two-wire cabling Relative humidity range 4%to 100%(condensing)• O W Built-in rapid shutdown compliant(NEC 2014&2017) Connector type MC4(or Ampnenol H4 UTX with additional 0-DCC-5 adapter) LLC) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) z o M Weight 1.08 kg(2.38 Ibs) J Productive and Reliable Cooling Natural convection-No fans Q LL Optimized for high powered 60-cell and 72-cell*modules Approved for wet locations Yes • More than a million hours of testing Pollution degree PD3 (/) w• Class II double-insulated enclosure Enclosure Class II double-insulated,corrosion resistant polymeric enclosure uj 5 J • UL listed Environmental category/UV exposure rating NEMA Type 6/outdoor Q FEATURES _ _ ... . __ J Communication Power Line Communication(PLC) J _ Smart Grid Ready Monitoring Enlighten Manager and MyEnlighten monitoring options. Q CO Both options require installation of an Enphase I0 Envoy. ~ W• Complies with advanced grid support,voltage and —_— frequency ride-through requirements Disconnecting means The AC and OC connectors have been evacuated and approved by UL for use as the load-break N disconnect required by NEC 690 Remotely updates to respond to changing Compliance CA Rule 21(UL 1741-SA) grid requirements UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, • Configurable for varying grid profiles CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and • Meets CA Rule 21(UL 1741-SA) NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC SHEET NAME and DC conductors,when installed according manufacturer's instructions. *The 107+Micro is required tosupport72-cell modules. 1.No enforced DC/AC ratio.Sea the compatibility calculator athttoa /enpbase.com/st//su000rt/module-compatibilitx. INVERT �ER 2.Nominal voltage range can be extended beyond nominal if required bythe utility. DATA SHEET 3.Limits may vary.Refer to local requirements to definethe number of microinverters per branch in your area. vEN PHASE. To learn more about Enphase offerings,visit enphase.com v EN PHASE. SHEET SIZE To learn more about Enphase offerings,visit enphase.com O 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,I c. ANSI B 2018-02-08 11" X 17" SHEET NUMBER DS-02