HomeMy WebLinkAbout21-1327 Q , D i�oniun - City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BGC-001327-2021 --- Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 02/02/2021 s Permit Type: Building General (Commercial) Property Number Street Address 35 25 210010 08800 0000 7348 Gall Boulevard Owner Information Permit Information Contractor Information Name: PROVEST TOWNVIEW LLC& Permit Type:Building General(Commercial) Contractor: FLORIDA SIGN COMPANY MISSION HILLS EQUITIES LLC Class of Work:Wall Sign Address: 7348 Gall Blvd Building Valuation:$2,400.00 ZEPHYRHILLS,FL 33542 Electrical Valuation:$50.00 Phone: Mechanical Valuation:$0.00 f Plumbing Valuation:$0.00 Total Valuation:$2,450.00 Total Fees:$145.50 G� Amount Paid:$145.50 Date Paid:2/2/2021 1:59:04PM Project Description INSTALLATION WALL SIGN 29.24 W ELECTRIC PINCH PENNY Application Fees Building Plan Review Fee $26.00 Building Permit Fee $52.00 Electrical Permit Fee $45.00 Electrical Plan Review Fee $22.50 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CO RACTOR SIGNATURE PE r IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received /` SCURNESUMqt'�, � _ Phone Contact for Permitting aaaateaaFViroRve ataaaOwner'sName 10'__' i1� ..��-�-c Owner Phone Number Owner's Address 1•Oi, K 5l J So 125341Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address 1 q °6 JOB ADDRESS .)Li p WA zqillAi ? 't L- LOT# SUBDIVISION PARCEL ID# 35"a5-Z 1- ®eR300 G€3 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT = SIGN � = DEMOLISH e INSTALL e REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL Q L DESCRIPTION OF WORK BUILDING SIZE SO FOOTAGE d►•� HEIGHT L'CLL-aa'LLa`a:CL'CC-L"CLCXWLf.L CLa aa'=•.L L L L L L C C a a a L L L C a L LL C L■.a a-a WN:L C-LLa-Ca LC 4L-9 BUILDING $ ©0.,00 VALUATION OF TOTAL CONSTRUCTION ELECTRICAL oO AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION r 7 SPECIALTY FINISHED FLOOR ELEVATIONS GAS ROOFING 0 FLOOD ZONEA OTHER AREA =YES NO BUILDER COMPANY or't�la-V� f-I CO.—L,(LC SIGNATURE REGISTERED Y/N I FEE CUMEN I Y/N Address I 1u)D'7Aye. W.B na mkz) r License li�7J 1 ELECTRICIAN COMPANY 1 Q m 6P.1h�. SIGNATURE- REGISTERED_ Y/N I FE URREN I Y/N Address [/ - License# PLUMBER COMPANY SIGNATURE REGISTERED. Y/N FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N 'FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE- REGISTERED I Y/N FEE CURREN Address License# aal Illegal I III lagalt''Il allililt istJ1l1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stonnwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Storrnwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet Compliance SIGN PERMIT Attach(2)sets of Engineered Plans. •"•PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner.&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) Agent(for the Contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit Issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,600.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant Is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be In compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LE "EX 13EF-ORE RECORDING YOUR ^^RAR9EbLQEME NT. FLORIDA JURAT(F.S.11 . 3 OWNER OR AGENT CONTRACTOR S bs� ribe'yd and�wo to( 4 bg re me this S ubs5-.2and by o (a ed)befo eQm_e this Vyt�§/are personally known to me has/have produced Who i5slare geerrsonally known tome or hag/have produced as identification. as identification. " Notary Public /1� 0o* p Notary Public C mmission No. , Com fission No. 19�� A 1 �a(pl'� Q IS0,r\0, �WCac\ � 1�e Name of Notary typed,printed or Aamped Name of Notary typed,printed or slam d r xr. KAREN 0.DRING ,r�Y PUB KAREN 0.DRING Commission#GG 293829 r6��:••• 4 r� �� Commission#GG 293829 * � •' N Expires May 21,2023 N��l \o� Expires May 21,2023 �►iF��oP Boded Thtu Budget NomryS*Nlcos fop Ft�F BandedThruBulptNotarySuviae SINCE 1951 AFL ORIDA SIGNCOMPANY January 5.,2021 City ofZephyrhills Department of Permitting Re: Pinch A Penny 7348 Gall Blvd Zephyrhills FL To Whom It May Concern, Please let this letter serve as my authorization for Lori Duvall, Beth Payne or James Duvall to submit or pick up permits or sign any documents necessary to obtain sign permits for the above. Sincerely, Charles Ogle Florida Sign Co. Inc 1101 29th Ave W Bradenton, FL 34205 941-747-1000 941-746-5689 (Fax) 941-238-7915 (cell) Sworn and subscribed before me this day of 20 by Charles Ogle who is person ly known Notary Name o14a��u� KAREN O.DRING Commiselon#GG 293829 Expires May 21,2023 yrFOFR,OQ� Bonded Tteu Budget NotaryServices i 1101 29THAVE. W. BRADENTON,FL. 34205 PH.(941)747-f000/FAX(941)746-5689 VISIT OUR WEBSITEAT FLORIDASIGN.COM "From Conception to Completion" i 11/11/2020 City of Zephyrhills Building Dept i Re: 7348 Gall Blvd, Zephyrhills, FL To whom it may concern, As owner or authorized agent for the above address please let this serve as my authorization for Florida Sign-Co Inc. to install signs and pull permits for the above address. Sincerely, printed name and date State of Florida County of Sworn to and subscribed before me this day ofjA& a r ,20 S gnature of Notary qVft Notary publlC State of Florida Noemi Figueroa Acevedo y My Commission GG 230983 vja� Expires 10112t2022 35-25-21-0-130 5-2L5-21;0010 Legend zEP6 fYR COl'iI3M®Ns z�P� lRtal>ILL cO NYC oMPANY LA g 'PRASE I P��1 PG 55 Street (Labels) Parcel (Lines) �RETT OND GOAD Subdivision 7 Q (Boundaries and Labels) i Pa rcels El (Clickable Info) Blocks (Boundaries and Labels) -- Lot (Lines) 352521-00: 0 ►'�__ zEPHYRHlLLS'.CoLONY,.coMPANY,LANDS PB:1 P6,5x-.47wN t. I y�3 � � ^ r.�rlr •�� FI F" 7, TOW,MEtNr<'4VENtAE .• Mi-keWells Pasco County Property Appraiser Property Appraiser Proudly Serving Pasco County,Florida 0 0.0175 0.035 0.07 mi I I I I I I I I I 11sl9n91 tl �7 n7 PM EasySeat.s . easyseals.conn DESIGN CALCULATIONS FOR r? •y - PINCH A PENNY WALL-MOUNTED.SIGNS Zephyrhills,FL This document has been Digitally signed GENERAL NOTES: digitally signed and sealed by g y SI g Christian Langley,PE on the b Christian 1. Design is in accordance with the Florida Building Code 7th Edition (2020) date noted in this digital y for use within and outside the High Velocity Hurricane Zone(HVHZ). signature. Printed copies of Langley this document are not g y 2. Wind loads have been calculated per requirements of 7-16 as considered signed&sealed,& Date: 2021.01.13' p q the signature must be verified shown herein. onan60y3ele 8roni co71 pieibncrn 18:16:38-05'00' 3. These engineering calculations pertain only to the structural integrity of those systems,components,and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The Index: .- existing host structure(if any)is assumed to be in good condition, _Pg i Cover capable of supporting the loaded system,subject to building department Pg 2 Wind Loads approval. No warranty,either expressed or implied,is contained herein. Pg 3 Anchor Design 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5. Where site conditions deviate from those noted herein,revisions may be Engineer's signature0 and seal valid required or a separate site-specific engineering evaluation performed. .�� - tom`` for; ages". 'tfiroag �3 6. Aluminum components in contact with steel or embedded in concrete shall be protected as prescribed in the 2015 Aluminum Design Manual, ". No. 67382 Part 1. Steel components in contact with,but not encased in,concrete ' �( � �r 4( shall be coated,painted,or otherwise protected against corrosion. �-o 4� 7. Engineer seal affixed hereto validates structural design as shown only. � '° STATE O ° � Use of this specification by contractor,et.Al,indemnifies and saves �,e'•°k,Jan^13�2Q210�, harmless this engineer for all costs&damages including legal fees& Christia S'Lb'Angl'ey #67382 apellate fees resulting from deviation from this design. Easy Seels,io,,,r Cert% #31124 1200 N Federal Hwy,#200 Boca Raton,FL 33432 Easy Sea I S.com Page 1 �as Seal5 CALCULATIONS FOR WALL-MOUNTED SIGNS easyseaissom / SCE 7-16 Design.Wind Loads WALL-MOUNTED SIGNS Building Specs V=- 140 mph' 'Basic wind speed ASD Load Combo Coeff: 0.6 Exposure! . C Calculations a= 9.5 3-sec gust speed power law exponent Kd= 0.85 Directionality factor zg=900, Nominal ht.of atmos.boundary layer Kzt= .. 1.0 Topographic factor Gcpi= 0 Internal pressure coeff Ke= 1.0 Ground elevation factor A= 10-sq ft ." Tributary area 140 mph Exp"C" WALL-MOUNTED SIGNS ASD WIND.PRESSURES SIGN - CENTER CORNER u n a HEIGHT" (Zone 4) (Zone 5) Y qz U_ U 15 ft 23.9 psf 30.4 psf" 0.85 36.2 -1.10 -1.40 20 ft.. 25.4 psf 32.3 psf. 0.90 38.5 -1.10 -1:40 -25 ft 26.6 psf 33.9 psf.- 0.95 40.3 -1.10 -1.40 30 ft: 27.6 psi $5.2 psf 0.98 .41.9 -1.10 -1.40 35 ft 28.6 psf 36.4-psf 1.01 43.3 -1.10 -1.40 40 ft 29.4 psf 37.4 psf 1.04 .44.5 -1.10 -1.40 45 ft 30.1 psf 38.3 psf 1.07 45.6 -1.10 -1.40 50 ft 30.8 psf 39.2 psf 1.09 46.6 -1.10 -1.40 55 ft 31.4 psf 40.0 psf 1.12 47.6 -1.10 _ -1.40 •60 ft 32.0 psi 40.7 psf 1.14" 48.5 -1.10 -1.40 70 ft-: 27.0 psf 54.1 psf 1.17 50.1 -0.90 -1.80 '.80 ft 27.8 psf 55.6 psf 1.21 51.5 -0.90 -1.80 90 ft" 28.5 psf 57.0 psf 1.24 52:8 -0.90 -1.80 100 ft 29.1 psf 58.3 psf 1.27 54.0 -0.90 -1.80 -110 ft :' 29.7 psf 59.5 psf 1.29 . 55.1 -Mo -1.80 126 ft 30.3 psf 60.6 psf 1.32 56.1 -0.90 -1.80 130 ft " 30.8 psf 61.6 psf 1.34 57.0 -0.90 -1.80 140 ft- . 31.3 psf 62.6 psf 1.36 57.9 -0.90 -1.80 150,ft 31.7 psf 63.5 psf 1.38 58.8 -0.90 -1.80 175 ft 32.8 psf 65.6 psf 1.42 60.7 -0.90 -1.80 .200 ft. 33.7 psf 67.5 psf 1.46 62.5 -0.90 -1.80 250 ft 35.3.psf . 70.-7 psf 1.53 65.5 -0.90, -1.80 Page 2 Easy Seals CALCULATIONS FOR WALL-MOUNTED SIGNS Wall Sign Anchor Design Structure Dimensions&.Loading Design wind pressure: P= . : 35.2 psf Sign type: r . Raceway. Sign size: h= : '20.0 ..inches (height) Wall.material: Masonry: ;(ASTM C90,1,500 psi min) Anchor type/size: j :1/4"Tapcori Ref: ITW Tapcon,catalog Min Embedment: 1" Min edge dist: 4" Anchor tensile capacity: Tcap= 125.0 lb (per anchor) . Check Anchors for Pullout .. Total Reaction: Rt= 59 Ib/ft, ...=P*ii (along raceway) Anchor.spacing req'd s= 51.2 in O.C. ..._(2*cap)/Rt Pairs of anchors at 51 inches on center(max). 4.3 feet on center OK,.typical anchor option shown. Limit to pairs at 48"O.C. max. Ref anchor.schedule for other anchor options. Page 3 Za N 'ANCHORSCHEDULL •ALL FAfrFNfRS SHALL BE.VAQBfVENLY•• I _ __11 QTYor SPACING, WALL MATERIAL ANCHORTYPE , . or tEfE(3laQ 1/4•TNREAOED RODS WITH MIN 2'EMBED INADNESIVE PAIRS AT 30°O.G CONO R HOLLOWMA1. or 1/4'TAPCONS(OR EQUIV)WITH 1.75°EMBED PAIRSAT48'O.C. - r 1/4-IXPANSION ANOIORS WITH 2.5-EMBED- PAIRSAT48'O.G' • Y" 1/2'PLYWOOD 1/4•,TOGGLE BOLTS, PAIRSAT48'0.C. . y� (NO ACCESS BEHIND) 1/4`WOODSCREWS,FULL EMBED PAIRS AT 46'0.C. , ��Sg I METAL STUDS/PANELS 414 METAL SCREWS TO MIN 18ea STEEL OR 0.090•ALUM .PAIRS AT 48.0.CG 3 � HOLLOW WALL.BLOCKING '1/4'THRUBOLTS OR LAGS TO SOUD BLOCKING BEHIND :PAIRS AT 48'O.G: s 20'STOREFRONT , . . .. - ra' 41... Izoss MIN(3)#10 SMs PER 210" LETTERTO RACEWAY.. . Rob .Its 20. FABRICATE AND INSTALL'RACEWAY MOUNTED CHANNEL'-LETTERS'WITH RED LED'S TO. ILLUMINATE LETTERS:,FACE COLORS TO BE 2283 RED WITH.GOLD TRIM CAP AND BRONZE RETURNS.PAINT RACEWAY TO MATCH SW 2804 RENWICK ROSE BEIGE- -_ sea PM This,alraiaing-Is'for illustration purposes only Colors and scaling in drawing may Dry°_ 5 '.' PROJECT NAME: PINCHAPENNYZEPERHILLS'DATE: 10/2a8/20 it .E[eaystlon m a0 Si.Or g �9 L]' g5 a �. . ' Fi Pe On all factor oxce4atlons Florida Sign Company will.notify Sunshine utility locate'servlco,to' a!?la T .Identify.participating mombors underground utilities.Any damage to private.utilities such es'sower lines,Irrlgetten, No water supplles,'eommunleatlon cables etc.will be'the responsibility of the owner to repair unless nodfleatlon has been given to Florida Sign Company In writing.of potential conflicts with underground services.At that time a Sitemete' to 'location or another.coarso of action will be discussed. o a Any unforsesn obstacles underground such as old"concrete pads or(ootinga,unusual soli conditions with o w ii .tom d a V5� excessive rock deposits or any other"surprises"that require extra_lahor or oqulpmont to excavate will be the responsibility of.the ¢ owner.PRIMARY WIRING TO SIGN BY OTHERS.WE WILL CONNECT TO PRIMARY IF WITHIN t0.OF SIGN AND,EASY CONNECTION. ,``,`Yt��11 Er1"''rf r7jr♦♦♦i�, I have carefully reviewed and hereby accept-the drawing(s).as shown. All Q? fLOR/ RCS/O�V COMPAN , 91q additional changes' must be in,writing'and approved by.both parties._ ��,,� e.. IQINLLYR.TIVE _ . $ _ ✓. SIGVA CHm OoTL,SIG Ir�fL n° C M a 110E�4tht�ven e.Westsv � Z.. a Brl!,1a1r.F 4205 .OD.: Signature date' Phone:941. 47 Fax:'94147 .561 ASCE 7.16 WIND LOADS: •Sign Height=30 ft max Wall components&cladding: 1200 N Federal Hwy,#200 Christian Langley 5f °• r11 - •V=140 mph•Exposure 'C •Kzl=1.A Kd=0.85,G=0.85 •Zone,[i±27.6psf Boca Raton,FL 33432 Florida PE#67382� 'W ..*•• t10� $o -Risk Category 2 Structure •ASDLoad CoeB=0.6 •Zone 5:t 35.2 psf, 1-888-371.3113 CertofAuth#31124�:0' rrerrr]Ltttlft, �.,