HomeMy WebLinkAbout21-1340 ( � I
D �
Q�
t �r�!►+�+f+_ City of ZephyrhillS PERMIT NUMBER
5335 Eighth Street
Zephyrhills, FL 33542 BNR-001340-2021
Phone: (813) 780-0020
Fax: (813)780-0021 Issue Date: 02/02/2021
I
Permit Type: Building New (Residential)
Property Number Street Address
04 26 21 0260 00000 0150 6849 Shelby Lynn Way
Owner Information Permit Information, Contractor Information
Name: LINKS AT CALUSA SPRINGS LLC Permit Type:Building New(Residential) Contractor: K HOVNANIAN FLORIDA
Class of Work:SFR Construct OPERATIONS LLC
Address: 2301 Lucien Way 260 Building Valuation:$148,230.00
MAITLAND,FL 32751 Electrical Valuation:$6,300.00
Phone: Mechanical Valuation:$5,200.00
Plumbing Valuation:$5,900.00I
Total Valuation:$165,630.00
Total Fees:$14,799.28
Amount Paid:$14,799.28 (/
Date Paid:2/2/2021 12:49:45PM
Project Description
CONSTRUCT SINGLE FAMILY 2,403 SQ FT LAC
Application Fees
SIF 1 percent Fee $83.28 Mechanical Permit Fee $66.00
3/4 Water Meter Fee(Calc) $732.71 Public Safety Impact Fee-Admin $26.35
Electrical Permit Fee $71.50 Building Plan Review Fee $385.58
School Impact Fee $8,328.00 Electrical Plan Review Fee $35.75
Water Connection Residential Fee $1,010.00 Public Safety Impact Fee-Police $254.00
Sewer Connection Residential Fee $2,090.00 Mechanical Plan Review Fee $33.00
Address Fee $30.00 Irrigation 3/4 Meter(Calc) $732.71
Building Permit Fee $771.15 Driveway Fee $45.00
Plumbing Plan Review Fee $34.75 Plumbing Permit Fee $69.50
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may bel additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
a IQ L014-Y
CONTMMTTR SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
INSTR#2021006668 OR BK 10256 PG 1594 Pagel of 1
01/12/2021 03:32 PM Rcpt:2247956 Rao:10.00 IDS:0.00 IT:0.00
Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller
Parcel ID Number:04-26-21-0260-00000-0 I'j 0
Prepared By Daphne Clark
and K Hovnanian Homes
Return To: 2301 Lucien Way,Suite 260
Maitland,FL 32751
NOTICE OF COMN[ENCEMENT.
State of Florida.
County of PASCO.
The undersigned hereby gives notice that improvements will be made to certain real property,and in accordance
with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement.
1. Description of property: LOT 15
Legal Description: LINKS AT CALUSA SPRINGS according to the plat thereof,as
recorded in Plat Book 81 Page 74-79 of the public records of Pasco
County,Florida.
Addresses f0$y9 Shel b,A L, nn 00-4. Zephyrhills FL 33542
2. General description of improvements: New Single Family Home
1
3. Owner information: Name Links At Calusa Springs,LLC
Address 2301 Lucien Way,Suite 260,Maitland,FL 32751
4. Fee Simple Title Holder:N.A.
5. Contractor name and address: Name K.HOVNANIAN FLORIDA OPERATIONS,LLC
Address 2361 Lucien Way,Suite 260,Maitland,FL 32751
6. Surety:N.A.
7. 'Lender:N.A.
8. Persons within the State of Florida designated.by the Owner upon whom notices or other documents may
be served as provides by 713.13(1)(a)7.,Florida Statutes: N.A.
9. In addition to himself,Owner designates the following to receive a copy of the Lienor's Notice as provided
in 713.13(l)(b),Florida Statutes. N.A.
10. Expiration date of notice of commencement:One year from the d to of recording.
WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13,FLORIDA STATUTES,AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY,A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTENT TO OBTAIN FINANCING,CONSULT
YOUR LENDER OT ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
11.Date Signed: 111112021 Signature of Owner's Agent
ict
es,Ma rans
Sworn to and subscribed before me this i 1.1 20Z 1,Eby,James Makransky who is personally known to me.
Notary Public
Daphne A Clark pPs �
My commission expires:6/27/2023'' �v ,�
Serial No.GG 308696 Nora Signature: - . teo+ otary seal:
tote of Florida,- County Of Pasco
his Is to certify that the foregoing Is a
e and correct copy of the document
file or of public record In this office.
ness my hand 9 d official seal this
n c
A day ofj10AUt-W 2.0;;)-1
ki AlvarerSowies,Esq.,tw &Comptroller
a 14
A 'k
86 asco C nt ,PArida
Deputy Clerk
i
INVOICE. 00� �
FOR OF
BILLING CONTACT
JAMES CLARK
K HOVNANIAN FLORIDA OPERATIONS LLC
2301 LUCIEN WAY STE 260
MAITLAND, FL 32751
i
INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION
INV-00002538 01/26/2021 01/26/2021 Due NONE
I
REFERENCE NUMBER FEE NAME TOTAL
BNR-001340-2021 3/4 Water Meter Fee(Calc) $732.71
Address Fee $30.00
Building Permit Fee $771.15
Building Plan Review Fee $385.58
Driveway Fee $45.00
Electrical Permit Fee $71.50
Electrical Plan Review Fee $35.75
Irrigation 3/4 Meter(Calc) $732.71
Mechanical Permit Fee $66.00
Mechanical Plan Review Fee j $33.00
Plumbing Permit Fee $69.50
Plumbing Plan Review Fee $34.75
Public Safety Impact Fee-Admin $26.35
Public Safety Impact Fee-Police $254.00
School Impact Fee $8,328.00
Sewer Connection Residential Fee $2,090.00
i
SIF 1 percent Fee j $83.28
Water Connection Residential Fee $1,010.00
6849 Shelby Lynn Way Zephyrhills, FL 33542 SUB TOTAL $14,799.28
REMITTANCE INFORMATION TOTAL $14,799.28
City of Zephyrhills
5335 8th Street
Zephyrhills, FL 33542
I
i
I
I
January 26,2021 5335 8th Street,Zephyrhills,FL 33542 _ - Page 1 of 1
i
i
I
613-796-0020' City of Zephyrhills;Permit Application Fa"13460-oozy
'Building Department
Date Received Z Phone ContacEfor Perinitt'Ing : 407 257 _6940
Owner's Name. LINKS AT CALUSA SPRINGS. LLC Owner Phone __Number 407-257-6940
Owner's Address 2301 Lucien Way, Ste 260, Maitland FL 32751 o InerPhone Number
Fee Simple Titleholder Name N/A . Owner Phone Number
Fee Simple Titleholder Address FNIA
JOB ADDRESS he lb I" nn Ua 2e h rl-,,11s FZ S `2 LOT*' -j -...•�.
suBDivi316N LINKS AT CALUSA SPRING PARCEL ID# 04-26 21-0260-00000»a 1 S 10
(OBTAINED FROM PROPERTYTAXNOTICE)
WORK PROPOSED r-71 NEW CONSCR 8 AIIDIALT Q I SIGN Q 0 DEMOLISH
INSTALL REPAIR
PROPOSED USE St?R X Q COMM INNER
TYPE OF CONSTRUCTION BLOCK 0 FRAME STEEL Q
DESCRIPTION&WoRK_ NEW SINGLE FAMILY HOME Total Sq Ft-�40 3) .
TOTAL Ursdet Roaf0g
BUILDING SIZE . sQ FOOTAGE Area( 34 HEIGHT -
®BUILDING $ ea VALUATION OF TOTAL-CONSTRUCTION
Mpt,ECTRiCAL $ AM-P SERVICE 150 ;� PROGRES .'E RGY Q *.R.E.C.
s.300.00
b
=PLUMBING $ 5,900.00 q
®MECHANICAL $ 5 200 Q� VALUATION OF MECHANICAL INSTALLATION
,=GAS ® ROOFING SPECIALTY [ ] OTHER
FINISHED FLOOR ELEVATIONS �_l�5. 3�� FLOOD.ZONE AREA YES ®.NO
K HOYNNNIAN FLORIDA OPERATIONS.3UiLDER: COMPANY
SIGNATURE REGISTERED RREN ,
w _
Address 2301 Lucien Way,Ste 260,,MaiBand FL 32751 License# �CBC1213 7.
ELECTRICIAN ,() COMPANY �RSTON ELECTRICAL SERVICES_ ,INC -
StGNATUR i`y`�{'''�' REGISTERED I Y IN FEE CURREn Y J N
Address 16812 Silver-Shores Lane Odessa FL 33556 License EC13002645. -�
'PLUMBER COMPANY BAYONET,PLUMBING HEATING&AIR-COND.LLC
.SIGNATURE. .. REGISTERED Y 1`N '` FEE cURREh Y J N
.Address P.O.Box 5308,Bayonet Point FL34674 License# CFC042998
f" t .
MECHANICAL -, coMPANY' AIR FLOW DESIGNS,INC.
.SIGNATURE { �•� REGISTERED Y 1 N-, FEE CURREN Ly J N
Address
250 Jasmine Rd.,GasselIe FL 32707 ticerise#. GAC1814423
DTHER ROOFER COMPANY HUGH MACDONALD/ALVAREZ ROOFING
;SIGNATURE i. REGISTERED Y l.N FEE CUR
REn Y 1 N
Address 10825 Tam Folsom Rd.,Thonotosassa,.FL 33592 License# CCC1329562HIM H!
RESIDENTIAL Attach-(2)-Plot Plans;.(2):sets of Building'Plans;(1)set of Energy Forms;11=0=.W,Permit for new construction,
Minimum teri(10)working days alter subinittai date. Requited onsite,Construction Plans;Storinwater Plans rvf Siii-Fence installed;
Sanitary Faailities4-1 diimpsw,,Site Work Permit for subdivisionstlarge projects
.COMMERCIAL Attach(2)complete sets of Building Plaris phis a Life Safety Page;(1)set of Energy Forms:R-O-W Permit for new construction.
Minimum:ten(10).working days.after-submittai date. Required onsite,Construction Plans;Stormwater Paris w1 Slit Fence installed,
Sanitary Facilities&'1 dumpster.Site Work Permit for all.new projects:AII.Commercial r6quirements must meet compliance.
SiGN PERMIT Attach(2)sets of Engineered Plans.
"`.PROPERTY.SURVEY required-for all NEW construction,
'`plrectionsd
Fill out.apptication completely
Owner&Contractor sign.back of application,.notarized
If over.$2500,a Notice'of Corrimenc6hient is regiriredi (AIC'upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Rero6fs if shingles Sewers Service Upgrades A/C 'Fences(PlottSurvey/Footage)
Driveways-Not over Counter if_on publto.roadways..needs ROW
i
D
L
r
x �
Single Family Dwelling
Plan Review Comments
1. F.F.E...shall be a minimum of 8" above the road elevation and an engineered site.plan.
I Lots shall be graded to comply with R401:3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4: Tie in survey required before pouring concrete.
y q p s of driveway thru the sidewalk shall have
5. Drivewa s require a R.O.W. use permit. All 4 side
expansion material.
6. All setbacks shall be met.
7: All.property markers shall be uncovered and marked at time of first inspection.
8: All A.D.A."requirements shall be met:
9. No electric, plumbing, mechanical, or framing shall be covered without an inspection.and
approval first.
10: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall-not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M3014 of the F:B.0
.12. Water heaters shall comply with section P607.3 of the F:B.C:
13. Foundation supports for A/C units shall.be raised at least 3" above finished grade. Ml308.1 .
14: Return air in all bedrooms. F.B.C. M1620.4
1.5. Smoke detectors are to be installed_ in accordance_ with.R313.1 of the.F.B.C.
16. All glazing requirements are to be in accordance with R308:4 of the F.B.-C:
17. All means of egress are to be in accordance with;R31 I of the F.B.C.
18. "Green gypsum board" shall riot be used as a backer in showers or tubs. R702.4.2 F.B.C.
10. Combination-type AM breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage.' They shall be installed in accordance with the'RB.C:
21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all
underground plumbing and electric.
22. All 2016 N.E.C. Codes will be enforced.
i
21 Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0
24. In accordance with the Land Development Code,lots shall be sodded before final at least.10
feet around the structure.
25. R403.5.3Hot water pipe insulation
insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall.be applied to the .
following:
Piping 3/;inch (19.1 mm) and larger in nominal diame_ter.
Piping:serving more than.one dwelling unit.
Piping located outside the conditioned space._
Piping from the water heater to a distribution manifold.
Piping:located under a floor slab. j
Buried in piping.
Supply and return piping in recirculation systems oth Ir than demand recirculation systems.
25. Blower door'test shall be provided before C.O:
26.A copy of the merry.cacls shall be with permit at all times-
27. Copy of final.insulddon report shall be provided iuith permit before final
28.No fence,Pool or'scre-en enclosure :is issued with:this-permit:
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 6t'Edition
R.O.W.-Right of Way j
A.D.A.=Americans with Disabilities Act_ N.E.C.-National Electric.Code (2016)
i
i
i
I
i
PLOT PLAN (NOT ASURVEY)
DESCRIPTION:LOT 15,
LINKS AT CALUSA SPRINGS, BASIS OF BEARINGS:
AS RECORDED IN PLAT BOOK 81, C,�6F-RW OF�SHELBY LYNN WAY
PUBLIC RECORDS BEARS S.62-03,37-W,PER PLAT.
PAGES 74-79,OF THE
OF PASCO COUNTY,FLORIDA.
THE PROPERTY DESCRIBED HEREON
IS LOCATED IN FLOOD ZONE W
PER FLOOD INSURANCE RATE MAP
NUMBER 12101 C 0289F,EFFECTIVE
DESCRIPTION:
14,COMMUNITY
DATE SEPTEMBER 26,20
No.120235 PANEL 0289 F.
LOT 14 1
Rr 4 '
S.87056'23"E. 108.00' i 18 RCP
S'Side Setback i Z�
—------------——
BO i aes i i 20 >—
Cqa aISO! Oq <
c>
Z SO 12.80i pmp;�Oiiam PADUE L0
LL
Lu Tot Pt—Dupont-A Z
0 ;E - ', N w lwd
LLJ uj Gamg�LEFT z
!2 �5.20'-
Ap7md llng Pian. cc
oG 12.80'1 a)
Lu CV) Proposed Lowest Flw'
Elw�ios.Wp�
Gm
0
04 sla z Grade 14 C14 W i JWI C
C strucfian
C�
z LOT 15
-70.00
09------------------- 5.20'-
N.87056'23"W. 108.00'
a
LOT 16
LEGEND)
61.3=780-0o20 City of Zophyrhi!!S Permi#Application Fax-M-760-0021
Building Departrneni
Date Received Phone Contact for.Permitting, 4 C17 257 -
Owner's Name LINKS AT CALUSA SPRINGS. LL6 Owner Phone Number 407-257-6940
Owner's Address 2301 Lucien Way, Ste 260 Owner.Phone Number
Fee Simple Titleholder Name I N/A Owner Phone Number
i.
Fee Simple Titleholder Address N/A
JOB ADDRESS a-9 y-`1---�-S h e0 b L n 4 Ze h �Ir;,1 I,,5 FL .3 3va LOT# —"-�
SUBDIVISION INKS AT CALUSA SPRINGS PARCEL ID# 04-261-21-0260-0000 4T►-S)
(OSTAINED FROM PROPERTYTAX'NOTicE)
WORK PROPOSED �} NEW caNST I� ADDIAL7 �'] SIGN 0 � DEMOLISH
Q INSTALL REPAIR
PROPOSED-USE LXJ SFR X COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME [ ] STEEL Q
i
DESCRIPTION OF WORK NEW SINGLE FAMILY HOME Total S
BUILDING SIZETA Under Roof S(,l FOOTAGE �n9�-"T1 HEIGHT
fZDI
BUILDING —?J VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ AMP SERVICE150 I [ PROGRESSfNERGY Q W.R.E.C.
ZIPLUMBING $5,900.00—�
li—]MECHANICAL VALUATION OF MECHANI I CAL INSTALLATION
=GAS ROOFING SPECIALTY OTHER
FlNISHE6 FLOOR ELEVATIONS FLOOD ZONE AREA ]YES® NO
BUILDER COMPANY
SIGNATURE R REGISTERED
Address License#
I
ELECTRICIAN COMPANY 1. 1
SIGNATURk -'�' REGISTERED Y/ N FEE CURREN
i
Address �, 'License#
err �rf i ar,
tee LL C.PhUMBERr COMPANY Fe k)< Zrrr Q' n C o + a^clsc
'SIGNATURE REGISTERED Y/N FEE CURREA LZIN
Address p.O. 40X 1994, bovee ,,PL 3 3527 License# 0000q`)-2o2O
MECHANICAL COMPANY
SIGNATURE � } REGISTERED I Y/ N " FEE cURREA
Address License# F
0T.HERROOFER ._— COMPANY
SIGNATURE l REGISTERED Y/ N 'FEE CURREN
Address License#
RESIDENTIAL Attach(2)Plot Plans;(2),sets of-Building Plans;(1)set of.Energy Forms;11-O-1IU Permit for new construction,
Minimum ten_(10)working,days after submittal date. Required onsite,'Constriction Plans,Stormwater Plans w/Slit Fence installed,
Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/iarge projects ~
'COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stonnwater Plans w/Silt Fence installed_,,
Sanitary Facilities&1 dumpster,Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
""PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out applicatoon completely.
Owner&Contractor"Sign.balk of"application,notarized
If over$2500,a Notice of Commencement Is required. (AIC upgrades over$7500)
" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
-OVER THE COUNTER PERMITTING (copy of contract-required)
-Reroofs if shingles Sewers Service Upgrades A/C Ferices(PlottSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The:undersigned"understands that this permit may be subject to"deed"rest ICUons"
which may be-more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor .or
contractors to undertake work, they may be required-to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as:to what licensing requirements may apply for the
intended work,they are advised.to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, .if the owner has hired 'a contractor or contractors, he is advised to have the contractors) sign .
portions of the "contractor Block" of this application for which they will!be responsible. If you, as the owner sign as-the
contractor, that may bean indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing-buildings, or expansion of existing buildings, as.specified in Pasco County Ordinance number 89-07 and.
90-07; as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that-Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must.be.paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I
certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner.", 1 certifythat 1 have obtaihed a copy of the above described document and promise in good faith to
deliver it to the"owner"'prior to commencement.:.
CONTRACTOR'SIOWNER'S AFFIDAVIT:, I.certifythat all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work•and installation as indicated. 1'certify that no work.or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all.laws regulating
construction; County,.and'City codes, zoning regulations, and, land' development regulations in'the jurisdiction: I also
certify that,I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance! Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,VllaterNllastewater Treatment:_ . .
Southwest Florida Water Management District Wells, ',Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls,-Docks, Navigable-;Waterways.
- Department of Health ,� Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
understand that thefollowing restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone-"V°unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it'is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State.of Florida.
If the fill material is to-be used In Flood Zone "A" in connection with a permitted building using stem_wall
constructional certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of.such fill will not adversely affect adjacent
properties: -If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building.permit issued under the attached permit application, for lots less than one(1)
acre wt ieh.,are..elevated,by fill,an engineered;drainage plan is required.
If I am,the-MENT_FOR'THE OWNER, I promise in good fai to With informithe owner of the permitting conditions set forth in
this aftidavilf�brior to commencing,construction. I understand that a separate permit may be required for electrical work,
plumbing;signs; .'I[ I*,:pools,air conditioning, gas, or other installations not'specifically included in the-application. A
permit issued shall be construed to be a license to proceed-with the-work and not as authority to violate, cancel, Alter,.or
set aside'any.pi ovisioi s''of the te-hnical codes; nor shall issuance of.a permit prevent the Building Official from thereafter
requiring4.correcti6n of errors in-plans,construction or violations of any�codes. Every permit issued shall become invalid
unless the work authorized by such°permit is commenced within six months..of permit issuance, or if work.authorized by
the permitsis suspended or abandoned for a period of.six(6)months afterthd1irn6Ahe work is commenced. An extension
may be requested, in writing,from_,the.Building Official for a.period-not to exceed ninety(90) days and will demonstrate
justifiable cause for the extension."''If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER:- Y. OUR;FAIL"URE TO RECORD A NOTICE OF-COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE-FOR`1MPROVEMENTS TO'YOUWPROPERTY.' IF YOU114TEND TO"OBTAIN FINANCING,CONSULT
WITH YOUR_LENDER.OR ANATTORNEY BEFORE'RECORDINGYOUR NOTICE'OF COMMENCEMENT.
FLORIDA JURAT(F.S. .03)
OWNER�ORAGENT CC9NTRACTOfi-
Ssscribed and swum to` r affirmed?? fore a this Subscribed and swo � ((or affirmed berore me this
b AM S MAT( SO ANTES BOWIE CLARK
o s/are personally known r haslhave roduced o is/are ersonall known to haslhave produced
as Identification. N/A as identification.
Notary Public Notary Public
Commission No. GG 308696 Commission No. GG 308696
Daphne Clark Daphne Clark
Name of Notary typed,printed or stamped Name of Notary typed;printed or stamped
t*aYpne� DAPHNEA.CLARK 2pt1�YF(/94P DAPHNEA.CLARK
Commission#GG 308696 * * Commission#GG 308696
ge Expires June 27,2023 °9 \aQ Expires June 27,2023
��OFf1.0a� BOfW6dR"&JW"WA= FFI�Q kr&dTh 6WQ6 waryser&,q
E12 W34
UGR=2711 BA8=816
S24 S24 N24
E12 W18 E34
FOP=72 1-. -_ _ ._Window___
E18
This is a acceptable Site plan submittal,to be included with the product approval cover sheet for windows; and can be obtained from
the Pasco County Property Appraiser web site.
Rev 2010-02
FORM R405-2017 STATE COPY
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation- Residential Performance Method
Project Name: KHO1830 Dupont(TAM) Builder Name: K Hovnanian Homes
Street: 6849 Shelby Lynn Way Permit Office: City of Zephyrhills
City,State,Zip: Zephyrhills,FL,33542 Permit Number:
Owner: Jurisdiction:
Design Location: FL,Tampa County:) Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall'Types(1692.9 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.70 ft2
b. Frame-Wood,Adjacent R=11.0 280.22 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d. N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1830.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1830.00 ft2
6. Conditioned floor area above grade(ft2) 1830 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(158.1 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 290
a. U-Factor: Dbl,U=0.34 101.94 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.63 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 26.9 SEER:15.00
c. U-Factor: Dbl,U=0.34 16.19 ft2
SHGC: SHGC=0.29 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a. Electric Heat Pump 28.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.530 ft.
Area Weighted Average SHGC: 0.259 14.Hot water systems
8. Floor Types (1830.0 sqft.) Insulation Area a.Electric Cap:50 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1830.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 60.31 PASS
Total Baseline Loads: 60.04
I hereby certify that the plans and specifications covered by Review of the plans and t11iE ST,q�,
this calculation are in compliance with the Florida Energy specifications covered by this ti� _ �0�,
Code. calculation indicates compliance � .�;,''�% •s+
with the Florida Energy Code.
PREPARED BY: Before construction is completed
DATE: 12-7 20M this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code. COD yV> �
OWNER/AGENT: .Scwa.R.2wercal BUILDING OFFICIAL:
DATE: 1/11/2021 DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403 13.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in;accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
12/2/2020 8:52 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4
A-26-21-0260-00000-0150 I Pasco County Property Appraiser https:Hsearch.pascopa.com/parcel.aspx?parcel=2126040260000000150
Parcel ID 04-26-21-0260-00000-0150 (Card: 1 of 1)
Classification 00000-Vacant
Mailing Address Property Value
LINKS AT CALUSA SPRINGS LLC Ag Land $0
2301 LUCIEN WAY STE 260 Land $23,079
MAITLAND, FL 32751 Building $0
Extra Features $0
Physical Address
6849 SHELBY LYNN WAY,
ZEPHYRHILLS, FL 33542 Just Value $23,079
Assessed (Non-School Amendment 1) $23,079
legal Description (First 200
characters)
Non-School Taxable Value $23,079
See Plat for this Subdivision School District Taxable Value $23,079
LINKS AT CALUSA SPRINGS PB 81 PG
074 LOT 15
Jurisdiction
CITY OF ZEPHYRHILLS
Land Detail (Card: 1 of 1)
Line JUse ;Code Description ;Z gingiUnits ; Type jPrice _Condition Value
.__... -.f.....- _ f - .
1 0100V I LP1-1 l SFR OPUD i 5,495.00 j SF j $6.00 i 0.70 11 $23,079
Additional Land Information_
- -------- _ -- - — - _----------
Acres Tax shborhood Codeia I F Area Code ? Neighborhood
- -- -- - ---- - --- - - - -__----.--------._:..-- --- ---... _9.. ----- - ---- -(-)
0.13 30ZH } -- j LKCS
Building Information (Card: 1 of 1)
Unimproved Parcel
Extra Features (Card: 11 of 1)
Line ;Code 'Descri tion Year Units Value
_....__-.. _. _-- _...__... P-._._.—_..__.__._-.-.__- i_....___._____._._-
No Extra Features
Sales History
Previous Owner: UNITED CAPITAL FUNDING CORP
Month/Year _. 9 _ Type - . _--------_-__
Book/Pa e T e DOR Cody rCondition `Amount
-- --- - - -- - _.. -- ----- - --- - _ I --- --o. ---- - -----_--------------_--_
10/2019 9987 /.0218 Warranty Deed ; 05 1 Vacant $2,760,000
04/2016 , ; -9350/-2262 _..._...__4......-_Certificate.of Title i__......._1.2..__._._.._.._F....._..Vacant $0..._...__.........
12/2011 ! 8639 / 3248 f Warranty Deed 05 Vacant $0
11/2011 8627 / 0126 Warranty Deed I 12 Vacant $0
_---._._-.------.---._--.-._ ;_ __. _...._...__.__...._.___.__-.__..-__.__-.._.;._._.._._-___.._..___... --_---_-----.---.-.--. ---_..._..___.__..__._._-----
05/2008 ( 7848 / 0427 j Quit Claim Deed i Vacant $0
05/2008 7836 / 1714 Certificate of Title I Vacant ! $0
i
l of 1 1/11/2021,2:16 PM