HomeMy WebLinkAbout21-1385 m ' �-�46 City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001386-2021 F Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 02/22/2021 • Permit Type: Electric Service Replacement/Misc Property Number Street Address 1126 210010 08100 0090 38801 9Th Avenue Owner Information Permit Information Contractor Information Name: FRANK BAKER ROBIN TIPTON Permit Type:Electric Service Replacement/M Contractor: GREENHOUSE SOLAR Class of Work:Add/Alter Residential Address: 38801 9Th Ave Building Valuation:$0.00 ZEPHYRHILLS,FL 33542 Electrical Valuation:$20,400.00 Phone: Mechanical Valuation: rj Plumbing Valuation: Total Valuation:$20,400.00 Total Fees:$213.00 Amount Paid:$213.00 Date Paid:2/22/2021 8:57:29AM Project Description INSTALLATION ROOF MOUNT SOLAR PV Application Fees Electrical Permit Fee $142.00 Electrical Plan Review Fee $71.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. RACTO SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permlttin 727- —--940- _- 25 -17-I-ri-I-I-T - - -- - - ._a I-i-�-� ... Owner's Name Robin Ti ton Owner Phone Number Owner's Address "38801 9th ave Ze h rhills, FL 33542" Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS "38801 9th ave Ze h rhills, FL 33542" LOT# 0 SUBDIVISION ZHLH PARCELID# 11-26-21-0010-08100-0090 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR Q ADDIALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE SFR = COMM = OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL = DESCRIPTION OF WORK INSTALL ROOF MOUNTED PV SOLAR SYSTEM 10.2KW SYSTEM BUILDING SIZE SQ FOOTAGE HEIGHT [:= / =BUILDING $ VALUATION OF TOTAL CONSTRUCTION fdl =ELECTRICAL $ 20 400.00 AMP SERVICE = PROGRESSENERGY = W. C. f =PLUMBING $ !v =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO — v BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# SL NATURE ` �4 ��A--.;COMPANY E REGISTERED GREEN HOUSE SOLAR FEE CURREN YrN Address st bea4ater, License# ee13005971 PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address I License# MECHANICAL COMPANY F SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII11111111111111111111' RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal dale. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stonmwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500.a Notice of Commencement Is required. (A/C upgrades over$7500; Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofsifshingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..neods ROW �' NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors.to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands, that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulafions, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Su scr' d an sworn t or aff e G by a by Who is/are personally known to me or has/have produced Who is/are personally know a or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of typed,printed orgoo 8I618son 23 s GREEN HOUSE SOLAR AND AIR INC. 13575 58th Street N. s Suite 253 Clearwater, FL 33760 2uaitifier: Robert Bussa EC13005971 1, Robert Bussa, authorize the following individuals to sign for an obtain permits: Stephanie Stephens Rachaei Hansen Signature of C lualifiec -� Date: _4Z�6z! Notary PUWIC State bt Florida +' oatta J mi.pple,_ . My Commission.GG 932423 �d rP Expires 11/1712023 GODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop, Pensacola, FL 32526 1 (850)712-4219 1 chadC@godwineng.com January 8, 2021 To: Zephyrhills Building Department 5335 8th St. Zephyrhills, FL 33542 Re: Tipton- Residential PV Roof Mount Installation 38801 9th Ave. Zephyrhills, FL 33542 Plan Reviewer, This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above. I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2020 Florida Building Code 7th Edition, FBC ASCE 7 Min. Design Loads for Buildings&Other Structures Per 2020 FBC,the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V„it) - 137mph 3sec gust, Exposure Category- B The PV System consist of the modules, railing, and connection hardware.The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is 24ga. Metal panel with min.1/2" plywood decking and 2"x 4"roof trusses 24" O.C. The roofing,decking,and roof trusses are in good condition.The existing structure will be adequate for supporting the additional PV dead load and wind loads. The securement method of the PV system is to be flush mounted to the metal panel roof with the Ironridge railing and the protea bracket metal mounts.The attachments can be attached up to 32" apart in roof zone 1,and 16" apart in roof zones 2 &3.The mounts should be staggered,where possible,to allow distribution of the design loads evenly to the structure.The mounts shall be installed with 4 x 6mm x 25mm Bi-metal self-piercing screws. Please see attached documents and contact me should you have any questions. Sincerely, D.Chad Godwin, PE 81360 Exp. 02/28/2021 ���1111III//��// 81160 � e s i s 0 ST E OF 10iOlAl. ASCE 7-16 CHAPTER 29 WIND LOADS-Rooftop Solar Panels Minimum Design Loads-Part 1:Enclosed(gable,h<60ft,7°<0<20°) Risk Category II Table 1.5-1 Load Types Load,PSf Basic Wind Speed(Ult) 137 mph Figure 26.5-1B Dead Load,D 3 Wind Speed(asd) 106 mph IBC 1609.3.1 Weight of Ice,Di 0 Roof Angle 18 Earthquake,E 0 Effective Wind Area 10.00 ftZ 26.20 Fluid,F n/a Wind Load Parameters Flood Load,Fa n/a Wind Directionality Kd 0.85 Table 26.6-1 Lateral Earth psi,H n/a Exposure Cat. B,C,or D B Section 26.7 Live Load,L n/a Topographic factor K„ 1.00 26.8 or 26.8.2 Roof Live,L, n/a Ground Elevation Factor Ka 0.86 Table 26.9-1 Rain,R n/a Velocity Exposure Coefficient K, 0.70 Table 26.10-1 Snow,S 0 Array Edge Factor -/E 1.50 29.4.4 Self-Straining,T n/a Solar Panel Equalization Factor -/a 0.80 Fig.29.4-8 Wind,W see calc Velocity Pressure qp 14.75 psf qi,=0.00256 K,K„KdKeVZ Wind-on-Ice,Wi n/a Mean Roof Height h 20.00 ft 0.4h 8.00 ft least horizontal dim 528 in 10%of least horizontal dim 4.40 ft Roof Zone Set Back a 4.40 ft Figure 30.3-2b(Gable roof,h<60ft,7°<0<20°) Zone 1 2e 2n 2r Be 3r GCP -2.00 -2.00 -3.00 -3.00 -3.00 -3.60 uplift GCP 0.50 0.50 0.50 0.50 0.50 0.50 downward p=gh(GCP)(-/E)(/J -35.40 -35.40 -53.11 -53.11 -53.11 -63.73 psf uplift p=gh(GCP)(-/E)(ya) 8.85 8.85 8.85 8.85 8.85 8.85 psf downward downward case 1 11.85 11.85 11.85 11.85 11.85 11.85 psf D+(0.6W OR 0.7E) downward case 2 6.98 6.98 6.98 6.98 6.98 6.98 psf D+0.75L+0.75(0.6W)+0.75(Lr or S or R) downward case 3 7.11 7.11 7.11 7.11 7.11 7.11 psf 0.6D+0.6W uplift case 1 -18.24 -18.24 -28.86 -28.86 -28.86 -35.24 psf D+(0.6W OR 0.7E) uplift case 2 -12.93 -12.93 -20.90 -20.90 -20.90 -25.68 psf D+0.75L+0.75(0.6W)+0.75(L,or S or R) uplift case 3 -19.44 -19.44 1 -30.06 1 -30.06 1 -30.06 36.44 psf 0.61)+0.6W uplift case 4 -32.40 -32.40 1 -50.11 1 -50.11 1 -50.11 60.73 psf D+W Design Calculations for the Use of bracket to metal roof Module Length C 5.42 ft Module Width B 3.33 ft Module Area A 18.05 ftZ Total Design Load(Uplift) Pdesign -32.40 -32.40 -50.11 -50.11 -50.11 -60.73 psf Total Design Load(Downforce) Pdesign 11.85 11.85 11.85 11.85 11.85 11.85 psf Design Load per Module T p -584.86 -584.86 -904.36 -904.36 -904.36 -1096.06 Ibs T p=A*Pdesign Design Load per Module Tdown 213.90 213.90 213.90 213.90 213.90 213.90 Ibs Tdn=A*Pdesign Distributed Load(Uplift) P&t.Up -87.82 -87.82 -135.79 -135.79 -135.79 -164.57 plf T p/B*2 Distributed Load(Down) Pdist.Down 32.12 32.12 32.12 32.12 32.12 32.12 plf Tdn/B*2 Railspan Between Anchor Points L 2.67 1.33 1.33 1.33 1.33 1.33 ft Point Load per Mount(Uplift) R -234.18 -117.09 -181.05 -181.05 -181.05 -219.43 Ibs Point Load per Mount(Down) R 42.82 21.41 21.41 21.41 21.41 1 21.41 Ibs 2.00 Pullout Value for 4 x Metal to Metal Screws Ultimate Pullout Wt 1266 1266 1266 1266 1266 1266 lbs Ultim t fVq j*PPP'r, rS-5l Design Pullout Value per Mount W, 633 633 633 633 633 633 /�IfQ� ePu��t�lu �//// SAFTEY FACTOR SF 2.70 S. 3.50 3.50 3.50 2.88 O . .81360 STA OF A �►� ®� GODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop, Pensacola, FL 32526 1 (850)712-4219 1 cliadogodwineng.com January 8, 2021 To: Zephyrhills Building Department 5335 8th St. Zephyrhills, FL 33542 Re: Tipton— Residential PV Roof Mount Installation 38801 9th Ave. Zephyrhills, FL 33542 Plan Reviewer, This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above. I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2020 Florida Building Code 71h Edition, FBC ASCE 7 Min. Design Loads for Buildings&Other Structures Per 2020 FBC,the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V„it) - 137mph 3sec gust, Exposure Category—B The PV System consist of the modules, railing, and connection hardware.The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is 24ga. Metal panel with min.l/a" plywood decking and 2"x 4"roof trusses 24" O.C. The roofing,decking, and roof trusses are in good condition.The existing structure will be adequate for supporting the additional PV dead load and wind loads. The securement method of the PV system is to be flush mounted to the metal panel roof with the Ironridge railing and the protea bracket metal mounts.The attachments can be attached up to 32" apart in roof zone 1, and 16"apart in roof zones 2 &3.The mounts should be staggered,where possible,to allow distribution of the design loads evenly to the structure.The mounts shall be installed with 4 x 6mm x 25mm Bi-metal self-piercing screws. Please see attached documents and contact me should you have any questions. Sincerely, D. Chad Godwin, PE 81360 Exp. 02/28/2021 �`� C, G * ; 1360 ; ` TAT OF ' �► ASCE 7-16 CHAPTER 29 WIND LOADS-Rooftop Solar Panels Minimum Design Loads-Part 1:Enclosed(gable,h<60ft,7°<6<20°) Risk Category II Table 1.5-1 Load Types Load,PSf Basic Wind Speed(Ult) 137 mph Figure 26.5-113 Dead Load,D 3 Wind Speed(asd) 106 mph IBC 1609.3.1 Weight of Ice,Di 0 Roof Angle 18 Earthquake,E 0 Effective Wind Area 10.00 ftz 26.20 Fluid,F n/a Wind Load Parameters Flood Load,Fa n/a Wind Directionality Kd 0.85 Table 26.6-1 Lateral Earth psi,H n/a Exposure Cat. B,C,or D B Section 26.7 Live Load,L n/a Topographic factor K,t 1.00 26.8 or 26.8.2 Roof Live,L, n/a Ground Elevation Factor Ke 0.86 Table 26.9-1 Rain,R n/a Velocity Exposure Coefficient K, 0.70 Table 26.10-1 Snow,S 0 Array Edge Factor 7E 1.50 29.4.4 Self-Straining,T n/a Solar Panel Equalization Factor ya 0.80 Fig.29.4-8 Wind,W see calc Velocity Pressure qp 14.75 psf qi,=0.00256 K,K,,K,KeV2 Wind-on-Ice,Wi n/a Mean Roof Height h 20.00 ft 0.4h 8.00 ft least horizontal dim 528 in 10%of least horizontal dim 4.40 ft Roof Zone Set Back a 4.40 ft Figure 30.3-2b(Gable roof,h<60ft,7°<6<20°) Zone 1 2e 2n 2r 3e 3r GCP -2.00 -2.00 -3.00 -3.00 -3.00 -3.60 uplift GC 0.50 0.50 0.50 0.50 0.50 0.50 downward p=gh(GCP)("/E)(/a) -35.40 -35.40 -53.11 -53.11 -53.11 -63.73 psf uplift p=gh(GCP)(7'E)('/a) 8.85 8.85 8.85 8.85 8.85 8.85 psf downward downward case 1 11.85 11.85 11.85 11.85 11.85 11.85 psf D+(0.6W OR 0.7E) downward case 2 6.98 6.98 6.98 6.98 6.98 6.98 psf D+0.75L+0.75(0.6W)+0.75(Lr or S or R) downward case 3 7.11 7.11 7.11 7.11 7.11 7.11 psf 0.6D+0.6W uplift case 1 -18.24 -18.24 -28.86 -28.86 -28.86 -35.24 psf D+(0.6W OR 0.7E) uplift case 2 -12.93 -12.93 -20.90 -20.90 -20.90 -25.68 psf D+0.75L+0.75(0.6W)+0.75(Lr or S or R) uplift case 3 1 -19.44 -19.44 1 -30.06 -30.06 1 -30.06 -36.44 psf 0.6D+0.6W uplift case 4 -32.40 -32.40 1 -50.11 -50.11 1 -50.11 60.73 psf D+W Design Calculations for the Use of bracket to metal roof Module Length C 5.42 ft Module Width B 3.33 ft Module Area A 18.05 ftz Total Design Load(Uplift) Pdesign -32.40 -32.40 -50.11 -50.11 -50.11 -60.73 psf Total Design Load(Downforce) Pdesign 11.85 11.85 11.85 11.85 11.85 11.85 psf Design Load per Module Top -584.86 -584.86 -904.36 -904.36 -904.36 -1096.06 Ibs Top=A*Pdesign Design Load per Module Tdown 213.90 213.90 213.90 213.90 213.90 213.90 Ibs Tdn=A*Pdesign Distributed Load(Uplift) Pdist.Up -87.82 -87.82 -135.79 -135.79 -135.79 -164.57 plf Top/B*2 Distributed Load(Down) Pdist.Down 32.12 32.12 32.12 32.12 32.12 32.12 plf Tdn/B*2 Railspan Between Anchor Points L 2.67 1.33 1.33 1.33 1.33 1.33 ft Point Load per Mount(Uplift) R -234.18 -117.09 -181.05 -181.05 -181.05 -219.43 Ibs Point Load per Mount(Down) R 42.82 21.41 21.41 21.41 21.41 21.41 Ibs 2.00 Pullout Value for 4 x Metal to Metal Screws Ultimate Pullout Wt 1266 1266 1266 1266 1266 1266 Ibs Ultimate WA�t 41POn�-5! Design Pullout Value per Mount W, 633 633 633 633 633 633 Allow\ Ueut(Dlue(e�p�� SAFTEYFACTOR SF 2.70 5.41 3.50 3.50 3.50 2.88 ® 4P , ® 60 e � e e e e a s STA OF ;��® Utility Meter P -COGEN Disconnect Located adjacent to Utility meter -SE7600H-US Inverter \\\\ /// SNP S�il� pE, o GpO�N G Sod Z Inverter Type: SolarEdge o PV Panel: (32)Hanwha Q-Cells 315W Racking: Iron Ridge 3' Access Pathway Total Wattage: 10,080W Roof Type: Metal Wind Load: 7 to 20 Deg Fastener Type: Use Protea Brackets Sheet Index S-1 Cover Sheet/ Site Plan _________________ j / / ____ __ ___ / " 7 / / / S-2 Detail E-1 One -Line S-lA Mounting Plan General Notes: -SolarEdge SE7600H-US Inverter located near utility meter -SolarEdge P320 Optimizers R-1 R-3 are located on roof behind each module. # Modules (16) # Modules (13) -First responder access maintained and o 31311 from adjacent roof. Pitch: 15O Pitch: 15 } -Wire run from array to connection is 60 feet. Azimuth: 1800 R-2 Azimuth: 180O 5' 6" # Modules (3) Pitch: 15O 3' Access Pathway Azimuth: 270O Layout Subject to Change Based on Site Conditions Green House Solar & Air \\\� / 14451 60th Street N, C g Godwin Engineering and ��� ®���� Nsoo`y��' Clearwater, FL 33760 FRONT OF H O IJ SE Design, LLC ®' ;Z 844-987-6527 .81360 8378 Foxtail Loop '�a • System meets the requirements of NFPA 70th Edition, Chapter 11.12 Install will be done to Manufacturer Spec p Pensacola, FL 32526 Meets All Editions of Florida Fire Prevention Code 6th Edition D. Chad Godwin, PEETA OF Customer Info: Legend ® Chimney Chad@godwineng.com First responder access Satellite ❑� Utility Meter 0 Vent Pipe Represents all Fire Clearance 1st Responder Access Robin Tipton Date: 1/8/2021 minimum of 36" unobstructed as per ❑J PV Disconnect SolarEdge Inverter including Alternative methods 3 8801 9th Ave. Drawn by: RF 1 Section R324 of the 2018 IRC Zephyrhills, FL Revised by: + 2020 FL Residential Code & FBC, 7th Edition (2018 International Residential Code - 2nd Printing Ze p h y Rev #: 00 modified by the FL Building Standards , 2018 International Energy Conservation Code, 33542 Rev Date: City of Zephyrhills Code, 2017 National Electric Code. Page: S-1 Compass for Aerial Solar Module 3/8-16 X 3/4 HEX HEAD @OAT 3/8-16 • ___________ VLA OE NUT 3- L - Ironridge XR-10 General Notes: Install will be done to Manufacturer Spec - S-5 Brackets are secured to Roof Godwin Engineering and @ 32" O.C. in Zone 1 , @ 16" O.C in Zone 2, & @ 16" O.C. in Zone 3 Design, LLC g =°� a ss� using (4) 6mm x 25mm BI-Metal Self-Piercing 8378 Foxtail Loop ° Pensacola, FL 32526 - Subject roof has One layer. D. Chad Godwin, PE ®-�� ��OpP �� - All enetrations are sealed. Chad@godwineng.com p ________rrlrttt,�____l%�1 Roof Section Pitch Roof Rafter and Spacing Overhang Notes: R1-R3 3/12 2"x4" @ 24 O.C. 20" Truss Green House Solar &Air 144 1 60th Street N, Customer Info: ` Clearwater, FL 33760 844-987-6527 Designed as per ASCE7-16 Inverter Type: SolarEdge g PV Panel: (32) Hanwha Q-Cells 315W Racking: Iron Ridge Robin Tipton Date: 1/8/2021 Total Wattage: 10,080W 38801 9th Ave. Drawn by: Imo' h r Modules mounted flush to roof Roof Type: Metal Ze hills, FL Revised b y: Wind Load: 7 to 20 Deg Zephyrhills, Rev #: 00 no higher than 6" above surface. Fastener Type: Use Protea Brackets 33542 Rev Date: Page: S-2 Equipment list I PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 1 1 1 T LABEL PER NEC 690.56(C)-PROVIDE AT NEW SUB 11l '1 '2 0 0 o y 5 16 P V: PANEL OR SERVICE PANEL FOR RAPID SHUTDOWN 2 J COMPLIANT SERVICES (32) Hanwha Q-Cells 315 W PHOTOVOLTAIC SYSTEM DC DISCONNECT MAX POINT CURRENT:25.2 A Apply to DC MAX POWER POINT VOLTAGE:400 VDC pp Y (32) SolarEdge Power Optimizer P320MAX MAX SYSTEM VOLLTTIT RE�480 DC disconnect/inverter — :15 A (2) strings of(16) WARNING ELECTRIC SHOCK HAZARD I 1 2 3 ° ° ° PTI1 [11Th Inverter: IF GROUND FAULT IS INDICATED ALL Apply to Inverter NORMALLY GROUNDED A4 (1) SolarEdge SE7600H-US CONDUCTORNSDMAY MAYBE U ENERGIZED ROUNDED SolarEdge AC/DC Safety Switch WARNING ELECTRIC SHOCK HAZARD AC Disconnect: DO NOT TOUCH TERMINALS Apply to Disconnects Power Optimizer TERMINALS ON BOTH THE LINE AND Soladeck 60A Disconnect LOAD SIDES MAY BE ENERGIZED IN Typ THE OPEN POSITION SOLAR PV SYSTEM EQUIPPED I WARNING 3/8 IN MIN.TEXT WITH RAPID SHUTDOWN All wiring to meet the 2014 NEC and ELECTRIC SHOCK HAZARD Apply to each J box, combiner 2015 Energy Code THE DC CONDUCTORS OF THIS z box, disconnect,and device where TURN RAPID PHOTOVOLTAIC SYSTEM ARE SHUTDOWN SWITCHT energized, ungrounded circuits 3/16 IN MIN.TEX THE"OFF'POSITION TrN\ UNGROUNDED AND MAY BE SHUT DOWN PV ENERGIZED maybe exposed during service. SYSTEM AND REDUCE SHOCK HAZARD IN TH WARNING ARRAY. • • • DUAL POWER SUPPLY 4 #10 AWG Wire ■ • SOURCES:UTILITY GRID AND PV Apply to MSP ( re SOLAR ELECTRIC SYSTEM ! WARNING ! (1)#8 EGcI RATED AC OUTPUT CURRENT: 32A I In 3/4"EMT typ or NOMINAL OPERATING VOLTAGE: 24 VAC POWER SOURCE OUTPUT CONNECTION: - Apply to Disconnects FMC,PVC,LFNC DO NOT RELOCATE THIS OVERCURRENT DEVICE (depending on route to Load Side Connection Inv.Metal if interior) Busbar Ratin 1 200 Main Breaker Size 1 200 Bus Rating*1.2-Main Break Size 1 40 Max Allowable Load Side 40 Load Size Breaker Size 1 40 SolarEdge Inverter Godwin Engineering and SE7600H-US Design, LLC w/Integrated Disconnect 8378 Foxtail Loop ®: ETATE •��y Main Service Pensacola, FL 32526 _ 0 �� Inverter Output Ckt Utility PV AC Disco 200A - p 60A Non-Fused Disconnect 200A Bus D. Chad Godwin, PE To Overcurrent Protection Device �tanaal Lockable Dsconnrrl , Chad@godwineng.com O'., F00 , AC Max Output Current 32 4oA i �''-�OR1O ,.• AC Max Output Current * 1.25% 40 Overcurrent Protection(A) 40 ��/111111�� No. of Current Carrying Cond <4 12) o, Conductor Gauge AWG 8 AWGTHWN IGEC Green House Solar & Air eal� 1445160th Street N, AWG EGC in'F least 3/4"Conduit Typically Load side connection Per 705.12(D)(2)(3)(b) Clearwater, FL 33760 System meets the grounding requirements of NEC 690.43 Use Matching or equivalent approved breaker if Berating Clearwater, 844-987-6527 Including the label below ' GEC NOTES Customer Info' Note: -All wiring the 2014 NEC and Provide a grounding electrode system for an to meet ungrounded system per 690.47(C)(3). Date: 1/8/2021 Inverter Type: Robin Tipton In Case of Emergency Call Florida electric codes. - GEC must be installed per 250.64 Drawn by: SolarEdge - GEC must be continuous un-spliced or irreversibly spliced from g 60A Disconnect inverter to existing service ground system or continuous from the 3880 1 9th Ave. PV Panel: Green House Solar & Air arrays to the service ground system. Revised b -Type of conduit to be determined existing y � (32) - 1f GEC is not continuous from the array to the existing service ground Zephyrhills, FL Rev #' 00 Hanwha Q-Cells 315W at 844-987-6527 on Site by contractor. an additional ground system must be provided from the arrays to a grounding electrode per 690.47(D) 33542 Rev Date: Total Wattage: Must be metal if DC ran interior. GEC must be min#8 AWG and installed in conduit 10,080W Install will be done to Manufacturer Spec - If GEC is not in conduit.it must be#6 min per NEC 690.54 Page: E-1 33'-1 0" -. Z /' /' / 23'-0" 17'-711 C� l 24'-5 - _ 15'-g R-1 R-2 # Modules (16) # Modules (3) Iron Ridge Rail Pitch: 15° Pitch: 15° XR-10 17' 6 Azimuth: 180° Azimuth: 270° 3'-3" 29'-10" X R- 0 4' 12 5' 6" Plans satisfy zones FBC-1510.7.1 Install will be done to Manufacturer Spec 17'-7" Bar Godwin Engineering and Splice 6 Design, LLC S-5! Protea Mounts 121 8378 Foxtail Loop ®' sso Iron Ridge UFO's 78 Iron Ridge Sleeves/End Caps 28 20'-5" Pensacola, FL 32526 ; *` D. Chad Godwin, PE ', STATE OF wZ 6x6 J-Box 3 odwinen com %�` ' , Iron Ridge Ground Lugs 7 R-3 Chad @g g aR,aP ���``'� Hanwha Q-Cells 315W 32 # Modules (13) SolarEdge P320s 32 SE7600H-US Inverter 1 Pitch: 15O 60A Non-Fused Disconnect I Azimuth: 180° Green House Solar&Air 40A Breaker 1 14451 60th Street N, Customer Info: Clearwater, FL 33760 Max cantilever is 10.67" as per manufacturer spec. 844-987-6527 Zone 1: Inverter Type: SolarEdge Max Cantilever = Max Span * (3)=32"*(3)=10.67" PV Panel: (32) Hanwha Q-Cells 315W Max cantilever is 5.33" as per manufacturer spec. Racking: Iron Ridge Robin Tipton Date: 1/8/2021 Zone 2: Total Wattage: 10,080W 38801 9th Ave. Drawn by: RF Max Cantilever = Max Span * (3)=16"*(3)=5.33" ' Roof Type: Metal Zephyrhills, FL Revised by: Max cantilever is 5.33" as per manufacturer spec. Wind Load: 7 to 20 Deg 33542 ' 3542 Rev #: 00 Zone 3: Fastener Type: Use Protea Brackets Rev Date: Max Cantilever = Max Span * (3)=16"*(�)=5.3.3" yp Page: S-1A powered by ' 1 DUO Format 66.3 in x 39.4in x 1.26in(including frame) (1685 mm x 1000 mm x 32 mm) 13.9.552.5•350 Weight 41.21bs(18.7 kg) �xaw a.wem°am ces•39 aya Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology_Back Cover Composite film 3)50.551 mm1 Frame Black anodized aluminum "`'"°°°"" Cell 6 x 20 monocrystalline Q.ANTUM solar half-cells Junction box 2.76-3.35 in x 1.97-2.76 in x 0.51-0.83 in (70-85mm x 50-70mm x 13-21 mm),decentralized,IP67 ••'�'�9 eh�TMlN "�'.°'"` Cable 4mm2 Solar cable;(+)x43.3in(1100mm),(—)a43.3in(1100 mm) 13B 52-a ,E u° 9.ew n°•350 Connector Multi-Contact MC4,IP68 I , UO • 300=320 POWER CLASS 300 305 310 315 320 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/—O W) Power at MPP' P , [WI 300 305 310 — 315 320 j ' 1 s ' , Short Circuit Currant' Ix [Al 9.72 9.78 9.83 9.89 9.94 _I e Open Circuit Voltage' Va [V] 39.48 39.75 ( 40.02 40.29 40.56 Current at MPP I,,, [A] 9.25 9.31 9.36 9.41 9.47 Voltage at MPP V,, IV] 32.43 32.78 33.12 33.46 33.80 The new Q.PEAK DUO BLK-05 solar module from Q CELLS impresses with Efficiency' r [%] ≥17.8 ≥18.1 ≥18.4 ≥18.7 ≥19.0 its outstanding visual appearance and particularly high performance MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT° _ on a small surface thanks to the innovative Q.ANTUM DUO Technology. Power at MPP P,p, [W] 224.1 1 227.8 231.6 235.3 239.1 Q.ANTUM's world-record-holding cell concept has now been combined E ( Short Circuit Current I� [A] 7.83_.I 7.88 7.92 7-97 8.01 with state-of-the-art circuitry half cells and a six-busbar design, thus I Ourrent tMPPltage V0 [V] 37.15 37.40 . 37.66 37.91 37. 5 Current at MPP I,r, [A] 7.28 7.32 7.37 7.411 7.45 achieving outstanding performance under real conditions — both with voltage at MPP V,1., [V] 30.78] 31.11 31.44 31.76 32.08 low-intensity solar radiation as well as on hot, clear summer days. 'Measurement tolerancesP,,,,�t3%;I�VVt5%atSTC:1000W/m2,25x2'C,AM1.5GaccordingtolEC60904-3.2800W/m2,NMOT,spectrumAM1.5G 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY rag 110 --r-----r— i �--- - At least 98%of nominal power during first year. r Higher yieldper surface area, lower BOS costs, higherpower - — °' -^°'°°g g I e= Thereafter max 0.54%degradation per year. o °' ----- At least 93.1%of nominal power up to 10 years. classes, and an efficiency rate of up to 19.3/a. At least 85%of nominal power up to 25 years. INNOVATIVE ALL-WEATHER TECHNOLOGY All data within measurement tolerances. S m Fulls of rtheies in LLS sales organithzation the war of oty Optimal yields, whatever the weather with excellent low-light terms the QCELLS sales of your and temperature behavior. V respective country. B0 2w ,,, lRRnounr�[wAx�21 Z 09, , ENDURING HIGH PERFORMANCE ' Typical module performance under low irradiance conditions In �, $.,III•3tl 1.n°NN..A..Nte IO PY comwnb YEARS �J' „a•3,„-,,,,��,d,-m�,,,�p,,,�,,,�,,,,,,,,°•,20,,, comparison to STC conditions(25°C,1000W/m2). Long-term yield security with Anti LID Technology, QCELLS ------------------- -- Anti PID Technology', Hot-Spot Protect and Traceable Quality Tra.QTM. no,aeA.roev TEMPERATURE COEFFICIENTS ry Temperature Coefficient of I 1 a I [%/K] +0.04 Temperature Coefficient e1 Va [%/K] —0.28 EXTREME WEATHER RATING Temperature Coefficient of PM„ I y,1 [%/K] —0.37 Normal Operating Module Temperature NMOT ['F] 109±5.4(43 t3°C) 2018 --- ——e - .4(4 _. High-tech aluminum alloy frame, certified for high snow r. t. , (5400 Pa) and wind loads (4000 Pa) regarding IEC. Maximum System Voltage V81, IV] 1000(1EC)!1000(UL) Safety Class It Maximum Series Fuse Rating (A DC] 20 Fire Rating C(IEC)/TYPE 1(UL) O A RELIABLE INVESTMENT 11_.]_=1Max.Design Load,Push/Pull(UL}x [lbs/1t2] 75(3600 Pa)/55(2667 Pa) Permitted module temperature —40°F up to+185°F Inclusive 12-year product warranty and 25-year ouality Tested on continuous duty (-40°C up to+85°C) linear performance guarantee2. l _ Max.Test Load,Push/Pull(UL)2 [Ibslft2] 113(5400 Pa)/84(4000Pa) 2 see installation manual ..grrl STATE OF THE ART MODULE TECHNOLOGY ID.40032587 r I r PACKAGINGr r UL 1703;VDE Quality Tested;CE-compliant; Number of Modules per Pallet 32 Q.ANTUM DUO combines cutting edge cell separation IEC 612152016;IEC61730:2016,Application classA 3 and innovative wirinwith Q.ANTUM Technology. t Number of Pallets per 53'Trailer 30 I APT test conditions according to s -- ---- v I EC/TS 6280412015, method B(-1500V, 168h) C E `�® Number of Pallets per 40'High Cube Container 26 I s D E Pallet Dimensions(L x W x H) 69.3 in x 45.3in x 46.9 in 2 See data sheet on rear for further c°i us (1760•3•3 x mmx1190 mm) x 11 THE IDEAL SOLUTION FOR: information. u�.LII - Pallet Weight 1415 lbs(642642 k&kg) s NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use '- - - Rooftop arrays on of this product. g i •I residential buildings Hanwha 0 CELLS America Inc. 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949 748 59 96 I EMAIL inquiry@us.q-cells.com I WEB www.q-cells.us Engineered in Germany .i6 CC:LLS Sin le Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ 1 I PhaseInverterZ SE7600H-US / SE10000H-US / SE11400H-USS e , • OUTPUT r Y i t h HE Wa ve Technology Rated AC Power Output 3000 3800 @ 208V 5000 6000 @ 208V 7600 10000 11000 @ 208VVA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA for North America 3300 @ 208V 5000 @ 208V 10000 @ 20Bv AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 240 SE3000H-US / SE3800H-US / SE5000H-US / SE6000H AC / AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac SE7600H-US / SE1 0000H-US / SE1 1400H-U (1S AC3r 20qu n229) AC Frequency(Nominal) 59.3-60-60.81- Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Currenu @240V ��� Maximum Continuous Output - 16 - 24 - - 48.5 A Current @208V GFDI Threshold 1 A Utility Monitoring,Islanding r solar ! ' .-. Protection,Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 I 7750 1 9300 11800 15500 17650 W Maximum DC Power @208V 5100 7750 - 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc r ■ rr � a3a « Nominal DC Input Voltage 380 I 400 Vdc Maximum Input Current @240VO 8.5 10.5 1 13.5 16.5 20 I 27 30.5 Adc _ijMaximum Input Current @208Vm - 9 - 13.5 - - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 99 @ 240V % CEC Weighted Efficiency 99 % 98.5 @ 208V Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optionalw Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect Optimized installation with HD-Wave technology 2017690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 / Specifically designed to work with / Extremely small Grid Connection Standards 1EEE1547,Rule 21,Rule 14(HI) power optimizers Emissions FCC Part 15 Class B I Record-breaking efficiency I Built-in module-level monitoring INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG 3/4'minimum/14-6 AWG 3/4"minimum/14-4 AWG Range Fixed voltage inverter for longer strings I Outdoor and indoor installation DC Input Conduit Size of Strings/ 3/4'minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/14-6 AWG AWG Range I Integrated arc faultprotection and rapid shutdown forp grade Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 mm 9 p I Optional: Revenue data, ANSI C12.20 (HxWxD) NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) WeightwithSafetySwitch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 Ib/kg Noise <25 <50 dBA I UL1741 SA certified,for CPUC Rule 21 grid Cooling Natural Convection compliance Operating Temperature Range -40 to+140/-25 to+60t'1(-40'F/-40'C option)ls> Protection Rating NEMA 4X(Inverter with Safety Switch) ('i For other regional settings please contact SolarEdge support SWar m R ven er current ve ter may SbeE used;the inverter will limit its input current to the values stated aRevenue grade inverter P/N:SExxxxH-USODONNC2 solaredge.com 'I For power de-rating information refer to:httpsVAvww.solaredge.com/sites/defaulVUles/se-temperature-derating-note-na.pdf 3l-40 version P/N:SExxxxH-US000NNU4 solarEdge Technologies,Inc All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BV SOLAREOGE are trademarks or registered trademarks of SolarEdge Technologies,Inc All Ro H S / Power Optimizer 0 For North America Power Optimizer P320 / P340 / P370 / P400 / P405 / P505 For North America P320 / P340 / P370 / P400 / P405 / P505 •• " .. •' .. •• .. INPUT Rated Input DC Power tt 320 340 370 1 400 405 505 W Absolute Maximum Input I Voltage 48 60 80 1259) 831st Vdc (Voc at lowest temperature) Q MPPT Operating Range 1 8-48 8 60 8 80 12.5 105 12.5 83 Vdc Maximum Short Circuit Current 11 I 10.1 14 Adc (Isc) Maximum DC Input Current I 13.75 12.63 17.5 Adc _Maximum Efficiency F .5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE II INVERTER OFF) N Safety Output Voltage per 1 t 0.1 Vdc Power Optimizer STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System F 1000 Vdc Voltage Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(WxLxH) 129x153x27.5/5.1x6x1.1 129 x153 x33.5/ 129x159x49.5/ 129x162x59/ mm/in 5.1x6x1.3 5.1x6.3x1.9 5.1x6.4x2.3 Weight(including cables) 630/1.4 750/1.7 845/1.9 1064/2.3 grub I Input Connector MC4oi Output Wire Type/Connector , Double Insulated;MC4 Output Wire Length 0.95/3.0 1.2/3.9 m/ft Input Wire Length F 0.16/0.52 m/ft Operating Temperature Range _ -40-+85/-40-+185 'C/°F PV power optimization at the module-level Protection Rating _ IP68/NEMA6P Relative Humidity 1 0-100 _ _ % m Rated SIC power of the module.Module of up to+5%power tolerance allowed 1 NEC 2017 requires max input voltage be not more than 80V f Specifically designed to work with SolarEdge F Fast installation with a single bolt 1s For other connector types please contactSolarEdge inverters 1 Next generation maintenance with module- .- Up to 25% more energy level monitoring Minimum String Length P320,P340,P370, 8 10 18 o (Power Optimizers) P400 Superior efficiency (99.5%) 1 Meets NEC requirements for arc fault P405/P505 6 8 14 protection (AFCI) and Photovoltaic Rapid Maximum String Length 25 25 S0Ie I Mitigates all types of module mismatch losses, (Power Optimizers) g yp Shutdown System (PVRSS) s7oo(600o rovitn from manufacturing tolerance to partial Maximum Power per String 5E7600-US-SE11400 5250 600131') 1275011 W shading I Module-level voltage shutdown for installer _ _ US) , _ Parallel Strings of Different Lengths Yes and firefighter safety or Orientations 1 Flexible system design for maximum space ")For detailed string sizing information refer to:http://wvnv.solaredge.com/sites/default/files/string-sizing_na.pdf utilization m R Is not allowed to mix P405/P505 with P320/P340/P370/P400 in one string A string with more than 30 optimizers does not meet NEC rapid shutdown requirements;safety voltage will be above the 30V requirement m For SE14.4KUS/5E43.2KIJ5:It is allowed to Install up to 6,500W per string when 3 strings are connected to the inverter(3 strings per unit for 5E43.2KUS)and when the maximum power difference between the strings is up to 1,000W m For SE30KUS/SE33.3KUS/SE66.6KU5/SE100KUS:It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter(3 strings per unit for SE66.6KUS/SE100KU5) and when the maximum power difference between the strings is up to 2,000W solaredge.com so I a r - i O SolarEdge Technologies Ltd.All rights reserved.S0LAREDGE.the SolarEdge logo,OPTUAIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc E ROHS All other trademarks mentioned herein em trademarks of their respective owners Date:122018N01/ENG NAM.Subjecttoochenge without notice. IRONRIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific S 4 ` design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. Solar Is Not Always hinny Over their lifetime, solar panels experience countless - extreme weather events. Not just the worst storms in years, a but the worst storms in 40 years. High winds capable of '-4_: "�" ripping panels from a roof, and snowfalls weighing i+, enough to buckle�a panel frame. (` _ XR Rails are the structural backbone preventing / -----_________ - - these results. They resist uplift, protect XR10 XR100 XR1000 against buckling and safely and efficiently XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among transfer loads into the building structure. rail,designed for regions with light or mounting rail. It supports a range of solar mounting rails.It's built to handle Their Superior Spanning capability no snow. It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans up to 12 remaining light and economical. maximizing spans up to 8 feet. feet for commercial applications. requires fewer roof attachments, _ reducing the number of roof - 6'spanning capability • 8'spanning capability • 12'spanning capability penetrations and the amount Moderate load capability Heavy load capability Extreme load capability • Clear&black anodized finish Clear&black anodized finish Clear anodized finish of installation time. - t internal splices available • Internal splices available • Internal splices available Rail Selection The following table was prepared in compliance with applicable engineering codes and standards. Values are ,f based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean I / Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. / .. .- .. - �. , Force-Stabilizing Curve 100 Sloped roofs generate both vertical and lateral 120 forces on mounting rails which can cause them None to bend and twist.The curved shape of XR Rails 140 XR10 XR100 XR1000 J is specially designed to increase strength in-both-__ directions while resisting the twisting.This unique 160 feature ensures greater security during extreme weather and a longer system lifetime. t 100 120 l0-20 1-'-- 140 160 100 30 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 1 100 XR Rails are IronRidge offers All XR Rails are made of 6000-series _ 40 compatible with a range of tilt leg aluminum alloy,then protected with an 160 FlashFoot and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing 50-70 160 attachments. applications, a more attractive appearance. 80-90 160 Utility Meter ALL WORK SHALL COMPLY WITH PREVAIUN -COGEN Disconnect CODES FLORIDA BUILDING CODE, Located adjacent to �@ NATIONAL ELECTRIC CODE, Utility meter AND THE CITY OF ZEPHYRHILLS ORDINANCES -SE7600H-US z o Inverter REVIEW DATE MAR 1 ' 2011 CITY OF ZEPHYRHI PLAN EXAMINER G Inverter Type: SolarEdge o PV Panel: (32)Hanwha Q-Cells 315W Racking: Iron Ridge 3' Access Pathway Total Wattage: 10,080W Roof Type: Metal Wind Load: 7 to 20 Deg Fastener Type: Use Protea Brackets Sheet Index S-1 Cover Sheet! Site Plan S-2 Detail / / E-1 One -Line S-lA Mounting Plan General Notes: -SolarEdge SE7600H-US Inverter located near utility meter -SolarEdge P320 Optimizers R-1 R-3 are located on roof behind each module. 2 # Modules (13) f� -First responder access maintained and # Modules (16) O -3 from adjacent roof. Pitch: 15 R-2 Pitch: 15 O -Wire run from array to connection is 60 feet. Azimuth: 180O Azimuth: 180 5' 6" j # Modules (3) Pitch: 15O 3' Access Pathway ``\,\11111l//�� Azimuth: 270O Layout Subject to Chan *%forgi1G�J4 ns Green House Solar & Air 14451 60th Street N, `* Clearwater, FL 33760 Godwin Engineering and = 844-987-6527 PRO W"' OF HOUSE Design, LLC 8378 Foxtail Loop O• OF System meets the requirements ofNFPA 70th Edition, Chapter 11.12 Install will be done to Manufacturer Spec p Pensacola, FL 32526 �� �+ •-.___.- �C?�� Meets All Editions of Florida Fire Prevention Code 6th Edition Customer Info: D. Chad Godwin, PE I//Ill Legend ® Chimney Chad@godwineng.com3 / ® First responder access Satellite Access Utility Meter 0 Vent Pipe Represents all Fire Clearance 1st Responder Robin Tipton Date: 1/8/2021 g including Alternative methods minimum of 36" unobstructed as per 38801 9th Ave. Drawn by: RF 1 \ LIIFU PV Disconnect L><] SolarEdge Inverter Section R324 of the 2018 IRC FL Revised b : 2020 FL Residential Code & FBC, 7th Edition (2018 International Residential Code - 2nd Printing Zephyrhills, Rev #: ` 00 modified by the FL Building Standards , 2018 International Energy Conservation Code, 33542 ______________ _____ ___ + Rev Date: City of Zephyrhills Code, 2017 National Electric Code. Page: s-1 Compass for Aerial Solar Module 3�/B-16 X 3/4 HEX HEAD BOLT z - .3/8-16 FUraheGE NUT Ironridge XR-10 General Notes: Install will be done to Manufacturer Spec - S-5 Brackets are secured to Roof \01111111/0 Godwin Engineering and @ 32" O.C. in Zone 1 , @ 16" O.C In Zone 2, & @ 16 O.C. in Zone 3 Design, LLC I ; o; using (4) 6mm x 25mm BI-Metal Self-Piercing 8378Fail Loop 32526 = * 13so Pensacola, - Subject roof has One layer. D. Chad Godwin, PE �o�., STA14 of Chad@godwineng.com �it�`s•:c�0R10?.-G����` - All penetrations are sealed. Roof Section Pitch Roof Rafter and Spacing Overhang Notes: R1-R3 3/12 2"x4" @ 24 O.C. 20" Truss Green House Solar &Air 14451 60th Street N, Customer Info: � Clearwater, FL 33760 844-987-6527 Designed as per ASCE7-16 Inverter Type: SolarEdge PV Panel: (32) Hanwha Q-Cells 315W Racking: Iron Ridge Robin Tipton Date: 1/8/2021 Total Wattage: 10,080W 38801 9th Ave. Drawn by: RF Modules mounted flush to roof Roof Type: Metal Revised by: no higher than 6" above surface. Wind Load: 7 to 20 Deg Zephyrhills, FL Rev #: 00 g Fastener Type: Use Protea Brackets 33542 Rev Date: Page: S-2 Equipment list PHOTOVOLTAIC EQUIPPED WITHTEM RAPID SHUTDOWN SYS1 LABEL PER NEC 600.56(C)-PROVIDE AT NEW SUB'1 '2 0 0 0 15 16 PV: PANEL OR SERVICE PANEL FOR RAPID SHUTDOWN !. J COMPLIANT SERVICES (32) Hanwha Q-Cells 315W PHOTOVOLTAIC SYSTEM DC DISCONNECT MAX POINT CURRENT:25.2 A Apply to DC MAX POWER POINT VOLTAGE:400 VDC MAX SYSTEM VOLTAGE:480 DC pp Y (32) SolarEdge Power Optimizer P320disconnect/inverter gp MAX CIRCUIT CURRENT:15 A (2) strings of(16) WARNING 1 2 3 15 16 ELECTRIC SHOCK HAZARD Inverter: IF GROUND FAULT IS INDICATED ALL Apply to Inverter NORMALLY GROUNDED (1) SolarEdge SE7600H-USAND CONDUCTORSENERGIZEDROUNDED _ = SolarEdge AC/DC Safety Switch WARNING ELECTRIC SHOCK HAZARD Power Optimizer AC Disconnect: DO NOT TOUCH TERMINALS Apply to Disconnects TERMINALS ON BOTH THE LINE AND Soladeck 60A Disconnect LOAD SIDES MAY BE ENERGIZED IN Typ THE OPEN POSITION SOLAR PV SYSTEM EQUIPPED WARNING 318IN MIN.TEXT WITH RAPID SHUTDOWN All wiring to meet the 2014 NEC and ELECTRIC SHOCK HAZARD Apply to each J box, combiner 2015 Energy Code THE DC CONDUCTORS OF THIS box, disconnect,and device where SHUTDOWN TURN SWATCH T PHOTOVOLTAIC SYSTEM ARE g g 3116 IN MIN.TEX THE"OFF"NOSITIOH T CD UNGROUNDED AND MAY BE energized, ungrounded circuits SHUT DOWN PV ENERGIZED maybe exposed during service. SYSTEM AND REDUCE SHOCK HAZARD IN TN ARRAY. WARNING UAL POWER SUPPLY I Apply to MSP # re 10 AWG Wi1111 jj'ire SOURC . ' ILITY GRID AND PV (4) SOLAR EL CTRIC SYSTEM ! WARN -! (1)#8 EGC In 3/4"EMT typ or POWER SOURCE OUTPUT CONNECTION: FMC PVC,LFNC • Apply to Disconnects DO NOT RELOCATE THIS OVERCURRENT Main Disconnnect DEVICE (depending on route to RATED AC OUTPUT CURRENT: 32A 200A Main inv.Metal if interior) NOMINAL OPERATING VOLTAGE: 240VAC L1 L2N Line Side SolarEdge In `ter Tap \ M Godwin Engineering and \%\ Design, LLC SE7600H S o ,�GEN F•,,�y��,�� w/Integrated sconnect 60A Service Rated 8378 Foxtail Loop 360 Fused Disconnect Neutral to Ground Bond = ; Pensacola, FL 32526 — � * �� ' = Inverter Output Ckt '� AC Disconnect . Chad Godwin, PE of ;feu Manual Lockable Disconnect o , To Overcurrent Protection Device - 40A Chad@godwineng.com FL QR110 AC Max Output Current 32 Fus N AC Max Output Current * 1.25% 40 u Overcurrent Protection (A) 40 a — No. of Current Carryin .Cond <4 Located Adjacent to Utility Meter GEC Ground Conductor Gauge AWG 8 1RefertoNEC3i28for #8 Li,L2 & neutral #6 Li,L2 & neutral Conditions on taps in switch Green House Solar & Air 8 Ground (1)#8AWG EGC&GEC and over current devices In 3/4" Conduit Enclosures. I 14451 60th Street N, If the conditions are not In @ least 3/4" Conduit met a tapboxwiIt Clearwater, FL 33760 System meets the grounding requirements of NEC 690.43 need to be installed. 844-987-6527 Including the label below Note: G : .NOT s er o: -All wiring to meet the 2014 NEC and Provide a grounding electrode system for an ungrounded system per 690.47(C)(3). Date: 1/8/2021 Florida electric codes. - GEC must be installed Inverter Type: In Case of Emergency CallRobin Tipton Drawn by: Imo' SolarEdge GEC Hurst be continuous per 250.64 i or irreversibly spliced from g 60A Disconnect inverter to existing service ground system or continuous front the 38801 9th Ave. NM PV Panel: Green House Solar & Air arrays to the existing service ground system. Revised b -Type of conduit to be determined (32> If GEC is not continuous from the array to the existing service ground Zephyrhills, FL Rev #• 01 Hanwha Q-Cells 315W at 844-987-6527 on site by contractor. an additional ground system(mist be provided from the arrays to a 3/3/2021 Total Wattage: Must be metal if DC ran interior. -rounding electrode per 690.47(Di 33 542 Rev Date: 10 080W - GEC must be min#8 AWG and installed in conduit Install will be done to Manufacturer Spec - If GEC is not in conduit it must be#6 min per NEC 690.54 Page: E-1 3 3'-l 0" 231_011 171_711 rrs rr 11'-3"LLLLL 24'-5" 15'-8" R-1 R-2 # Modules (16) # Modules (3) Iron Ridge Rail Pitch: 15O Pitch: 15O XR-10 17' 6 Azimuth: 180° Azimuth: 270° 3'-3" 29'-10" XR-10 1 12 < / // / / / / 51_611 Plans satisfy zones FBC-1510.7.1 Install will be done to Manufacturer Spec „�. 171_711 `�����1►l��t/����i Splice Bar 6 Godwin Engineering and S-5! Protea Mounts 121 Design, LLC Iron Ridge UFO's 78 8378 Foxtail Loop * ; 1360 Iron Ridge Sleeves/End Caps 28 _ 201_511 Pensacola, FL 32526 r , D. Chad Godwin, PE �', sTa OF Iron Ridge Ground Lugs 7 ,`cv 6x6 J-Box 3 R_3 Chad@godwineng.com '� :•.' �oRIo�:• Hanwha Q-Cells 315W 32 # Modules (13) SolarEdge P320s 32 Pitch: 15° SE7600H-US Inverter 1 60A Fused Disconnect 1 Azimuth: 180° Green House Solar &Air 40A Fuses 2 14451 60th Street N, Customer Info: Zone 1: � Clearwater, FL 33760 Max cantilever is 10.67" as per manufacturer spec. 844-987-6527 Inverter Type: SolarEdge Max Cantilever = Max Span * (3)=32"*(3)=10.67" PV Panel: (32) Hanwha Q-Cells 315W Max cantilever is 5.33" as per manufacturer spec. Racking: Iron Ridge Robin Tipton Date: 1/8/2021 Zone 2: Total Wattage: 10,080W 38801 9th Ave. Drawn by: >� Max Cantilever = Max Span * (3)=16"*(3)=5.33" ' Roof Type: Metal Zephyrhills, FL Revised by: NM Max cantilever is 5.33" as per manufacturer spec. Wind Load: 7 to 20 Deg Rev #: 01 Zone 3: Fastener Type: Use Protea Brackets 33542 Rev Date: 3/3/2021 Max Cantilever = Max Span * (3)=16 *(3)=5.33" Page: S-l A