21-1413
t m v ►��,�� Cityof Ze h p Y rhills PERMIT NUMBER ' 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001413-2021 Phone: (813)780-0020 Fax: (813) 780-0021 Issue Date: 02/2312021 Permit Type: Electric Service Replacement/Misc Property Number Street Address 35 25 21 0140 00800 0280 7808 Broad Pointe Drive Owner Information Permit Information Contractor Information Name: ROSAIDY&SERRANO MUNOZ Permit Type:Electric Service Replacement/M Contractor: MOMENTUM SOLAR- Class of Work:Add/Alter Residential SOLAR Address: 7808 Broad Pointe Dr Building Valuation:$24,255.00 ZEPHYRHILLS,FL 33540 Electrical Valuation:$1.00 Phone: (321)247-6073 Mechanical Valuation: Plumbing Valuation: Total Valuation:$24,256.00 J z Total Fees:$390.06 Amount Paid:$390.06 Date Paid:2/23/2021 3:42:33PM Project Description INSTALLATION ROOF TOP PHOTO VOLTAIC SOLAR W/ELECTRIC Application Fees Electrical Permit Fee $45.00 Electrical Plan Review Fee $22.50 Building Permit Fee $161.28 Building Valuation Fee $161.28 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PEf IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INSTR#2021014529 OR BK 10263 PG 3331 Page 1 of 1 01/25/2021 10:13 AM Rcpt:2252271 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles, Esq.,Pasco County Clerk&Comptroller Permit Number: Follo/Parcel ID#: 3525210140008000280 Prepared by: Lauren EI-Taher/Momentum Solar 6210 Haffner Ave Suite 1 Orlando,FL 32822 Return to: Momentum Solar 6210 Haffner Ave,Suite 1 Orlando;FL 32822 NOTICE OF COMMENCEMENT State of Florida,County of The undersigned hereby gives notice that Improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes,the following'Information is provided In this Notice of Commencement. 1. Description of properly(legal description of the property,and street address ff available) ZEPHYR LAKES SUBDIVISION PHASES 1A 2A 2B S 4A PB 80 PG 37 BLOCK 8.LOT 28 2. General description of Improvement 7808 BROAD POINTE DRIVE,ZEPHYRHILLS,FL 33540 Installation of photo voltaic solar panel on rooftop 3. Owner information or Lessee Information If the Lessee contracted for the Improvement Name Rosaldy Adomo Munoz Address 7808 BROAD POINTE DRIVE,ZEPHYRHILLS,FL 33540 Interest In Property Owner Name and address of fee simple titleholder(If different from Owner listed above) Name N/A Address 4. Contractor Name Momentum Solar/Cameron Christensen Telephone Number 321-247-6073 Address 6210 Haffner Ave,Suite 1,Orlando;FL 32822 5. Surety(If applicable,a copy of the payment bond is attached) Name N/A Telephone Number Address Amount of Bond $ 6. Lender Name N/A Telephone Number Address 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by§713.13(1)(a)7,Florida Statutes. Name N/A Telephone Number Address 8. In addition to himself or herself,Owner designates the following to receive a copy of the Llenor's Notice as provided In§713.13(1xb),Florida Statutes. Name N/A Telephone Number Address 9. Expiration date of notice of commencement(the expiration date will be 1 year from the date of recording unless a different date is specified) 07/22/2021 WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART L SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE R D ED THE JOB SrE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WRH ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Owner Swww or or ,'or Owner's or Lessae's Authorized ORlcer0 edodPerinadVeneger Signator�fa 7rdeJOrfice The foregoing instrument was edcnowledged before me this 22 day of 01/2021 by Roseldy Adoring Munoz mmilow name of person as Owner for attorney in Ted Name of party on befreli of whom inabunent was eurecuted Nicole Schiller { tGn Pu PdrrR type, stamp DomrNseloned name oT Notary Public Personally Known -A OR Produce ID JAB-. Type ofIDProduced t NIGGLE SCHILLER In Person-1-or On4ine Signatures r,, ur,�=Notary Public-State of FlorTde �• •_ Commission#HH 46180 MSoler23,2i024 Expires e b 813-780-0020 City.of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 321 247 6073 aaaaaaaa aaaaa Owner's Name Rosaldy Adomo Munoz owner Phone Number. (321)247-6073 Owners Address .7808 BROAD POINTE DRIVE Owner Phone.Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 7808 BROAD POINTE DRIVE,.ZEPHYRHILLS,FL 33540 LOT# 28 SUBDIVISIONZephyr Lakes PARCELID#F3525210140008000280 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT' . 0 SIGN = 0 .DEMOLISH ® INSTALL .e REPAIR PROPOSED USE = SFR 0 COMM OTHER TYPE OF CONSTRUCTION =, BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK Installation of photovoltaic solar panel on rooftop BUILDING SIZE SO FOOTAGE HEIG BUILDING $ VALUATION OF TOTAL CONS RUC ION 255 QELECTRICAL $ AMP SERVICE PROG ESS E GY = W.R.E.C. =PLUMBING $ X-DUKEENERGY =MECHANICAL $ VALUATION OF MECHANICA LATI =GAS = -ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA =YES NO .BUILDER COMPANY MOMENTUM SOLAR. SIGNATURE REGISTERED I. Y/N I FEE CURREN Y/N Address 6210 Hoffner AIve Ste 100 Orlando FL 32822 License# CVC57036 ELECTRICIAN COMPANY MOMENTUM SOLAR SIGNATURE REGISTERED Y/N FEE CURREN Y/N ' Address 6210 Hoffner Ave.Ste 00 ,landG FL 32822 License# EC13008217 PLUMBER COMPANY SIGNATURE REGISTERED I YIN FEE FEECURREN '�Y/,N Address License# 'MECHANICAL COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN I Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED I Y/N FEE CURREN Y/N Address License# !!!!!!!lift!!!!!t!■!lift!!!!!!!!!!!! t!!t!!!!t!!!!tt!!t!!!'!!!!!'t!1!!1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisionsnarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Ufa Safety,Page;(1)set of Energy Fortes.RwO-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. -PROPERTY SURVEY requlred.for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required.(A/C upgrades over$7500) •• Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department i NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy'orfinal power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner,I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN NANCING,CONSULT WITH YQUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF ... FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this SPh. crib and sworn (or affirmed)b o e t 's by by Who is/are personally known to me or has/have produced is/ a personally known to me or has/have produced as identification. as identification. Notary Public Public Commission No. Commissio No. Nicole Schiller Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped �vaYpr.,, NICOLE SCHILLER ♦P UB��i 20 Notary Public•State of Flori a ._ Commission N HH 46180 P� My Commission Expires %,°;;;°�� September 23, 2024 1/22/2021 35-25-21-0140-00800-0280 1 Pasco County Property Appraiser Parcel ID 35-25-21-0140-00800-0280 (Card: 1 of 1) Classification 00000-Vacant Mailing Address Property Value MUNOZ ROSAIDY EMILIE A &SERRANO Ag Land $0 ISAAC S Land $23,000 7808 BROAD POINTE DR Building $0 ZEPHYRHILLS, FL 33541 Extra Features $0 Physical Address 7808 BROAD POINTE DRIVE, Just Value $23,000 ZEPHYRHILLS, FL 33540 Assessed (Non-School Amendment 1) $23,000 Legal Description (First 200 characters) Non-School Taxable Value $23,000 See Plat for this Subdivision School District Taxable Value $23,000 ZEPHYR LAKES SUBDIVISION PHASES 1A 2A 2B &4A PB 80 PG 37 BLOCK 8 LOT 28 Jurisdiction CITY OF ZEPHYRHILLS Land Detail (Card: 1 of 1) Line,Use _Code Description _ Zoning;Units_ Type jPric ond_ition Value 1 ; 0100V I LP1-1 _ SFR I IOPUD j 4,600.00 P SF i $5.00 1 1.00 $23,000 - _ Additional Land_Information Acres_ j Tax Area 1 FEMA Code --( Neighborhood Code(s) 0.11 30ZL -- ZPLK Building Information (Card: 1 of 1) Unimproved Parcel Extra Features (Card: 1 of 1) _ Line —,Code- - Description Year _Units Value No'Extra Features Sales History Previous Owner: DR HORTON INC Month/Year �lBook/Page IType _ODOR Code Condition Amount _ _12/2020 _ _10229 / 3374 1 Warranty Deed j 01 Vacant 1 $241,000 03/2020 10073 / 2619 i _ Warranty Deed 1 05 Vacant j $325,500 09/2011 8606 / 3376 _ Warranty Deed �l 05 ---f Vacant j $0 06/2010 _ 8360 / 1872 Certificate of Title 12 Vacant I $0 06/2006 70_17 / 0395 - Quit Claim Deed Improved $0 05/2006 �7026 / 0555 Warranty Deed I Improved $0 https://search.pascopa.com/parcel.aspx?parcel=2125350140008000280 1/1 T 3 is Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman NJ.08558 908-872-3664 StudioGdesign@comcast.net January 21,2021 Re:Proposed Photovoltaic Solar Panel Installation Rosaidy Adorno 7808 BROAD POINTE DRIVE ZEPYRHILLS,FL 33541 Dear Plan Reviewer: Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Regarding the solar panel array installation on the above referenced project please note that an inspection was performed by a representative of the Architect/Engineer.of Record,and analysis of the existing structure was conducted.There is adequate structural capacity for the installation of the array with the following recommendations: 1.The array will be installed on the existing roof.The roof framing is constructed of 2"x4"wood trusses @24"o.c. spanning 15'with a top chord length of 167'with intermediate supports at 1/2 points,making the effective longest span equals 9'5" with 1/2"plywood sheathing.The new array(See Site map by contractor)will add 2.63 Lb./SE overall to the roof.No additional structural support is required for the roof structure. 2.The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed instructions.The attachment system shall be UL 1703 approved tested.Provide 6 mil.vapor barrier between dissimilar metals.Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer's installation manual.The panel angle shall match the roof slope.Reference summary table below: Roof Type: Shingle Fastener Max Spacing(in.) Attachment System: "Ecofasten Solar""Rock-IT'® Wind Zone 1 Wind Zone 2 Wind Zone 3 Fastener Info: min.5/16"x 4"long stainless-steel lags with a min. 48 24 24 embedment of 3"into the rafters 3.Solar Modules shall be UL-1703 rated.Refer to manufacturers specifications sheets. 4.Positive drainage of the system shall be so as not to void the existing roof warranty. 5.All aspects of the installation shall comply with the Florida Administrative Code,2020 Florida Building Code- Residential Seventh Edition,ASCE-7-16,2020 Florida Building Code—Energy Conservation,Seventh Edition,2017 National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by law.All components used meet the criteria of the Florida Solar Energy Center. 6.Please refer to the attached structural calculations. If you have any questions relating to this matter,please contact me at your earliest convenience.Thank you. CO.." •.® ® EL W. Daniel W.Dunzik,RA.LEED-AP o FL.Lic.No.AR98795 �', AR987 5 •:� ��®All i Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman NJ.08558 908-872-3664 StudioGdesign@comcast.net January 21,2021 Gravity Load Calculation Criteria Structural Design Loads per ASCE 7-16 Dead Loads= 10 psf+2.6 psf(new solar panels)=12.6 psf Roof Live Load=20 psf Ground Snow Load/Live Load=0 psf Wind Load Calculation Criteria Wind Loads per ASCE 7-16,Ch.30 method 1 Using an area of 10 SF,wind loads from Figure 30.5-1: Zone 1 =-36.5 psf Roof Slope=21 degrees Roof Mean Height= 15 ft Zone 2=-47.4 psf Basic Wind Speed=140 mph Zone 3=-54.7 psf Exposure=B Per section 2.4.1,ASD combo=D+0.6W: Zone 1 =2.6 psf+0.6(-36.5 psf)_-19.3 psf Zone 2=2.6 psf+0.6(-47.4 psf)_-25.8 psf Zone 3=2.6 psf+0.6(-54.7 psf)_-30.2 psf Check Attachment to Wood Truss Use 5/16 dia.Lag screw w/3"embedment into 2 in.wide roof rafter Lag Screw Spacing: Lag Screw Tributary Area: Zone 1 = 48"o.c.max Zone 1=(48"o.c.max)^2/144= 16 SF Zone 2= 24"o.c.max Zone 2=(24"oX.max)^2/144=4 SF Zone 3= 24"o.c.max Zone 3=(24"o.c.max)^2/144=4 SF Lag Screw Forces: W=2661b/in(Table 12.2A,2015 NDS) Zone 1 =19.3 psf x 16 SF=309 lb < W', OK Cd=1.6(Table 2.3.2,2015 NDS) Zone 2=25.8 psf x 4 SF= 103 lb < W', OK Ct=1 (Table 2.3.3,2015 NDS) Zone 3=30.2 psf x 4 SF= 121 lb < W', OK W'=W x embed x Cd x Ct W'=266 lb/in x 3 in.xl.6 x 1 = 1276.8 lb e 1r 1st LG N ' ON'02 LG350N1 C-V5 35OW The LG NeON®2 is LG's best selling solar module,and is one of the most. powerful and versatile modules on the market today.Featuring LG's Cello. Technology,the LG NeON®2 increases power output.New updates include an extended performance warranty from 86%to 90.08%to give customers higher performance and reliability. OVE C UL US C �� 1c i 1 Features Enhanced Performance Warranty Enhanced Product Warranty 4 - LG NeONW 2 has an enhanced . LG has extended the warranty of-the performance warranty.After 25 NeON®2 to 25 years including labor, years,LG.NeON®2 is guaranteed at which is top level in the industry. least 90.08%of initial performance. s. Better Performance on a sunny Day Roof Aesthetics 1y� LG NeON15 2 now performs better on LG NeONm 2 has been designed with sunny days,thanks to its improved aesthetics in mind using thinner wires temperature coefficient. that appear all black at a distance.The LG NeONm 2 can increase the.aesthetic value of your home.with a more modem design.. When you go solar,ask for the brand you can trust:LG Solar About LG Electronics LG Electronts is aglobal leader in electmNc pmdu=In the dram energy_*a.bynftnng solar PV pants and ena gy storage cyst--.The m pM fhst--baked on a War energy source research programin 1985,supported by LG Gmups ecteatertenre in theseny-wndunar.LCD;dem1my and materials industries.In 2010.LG 5olarwccesAully .�0 ar released hs 1'kat M=.X-series to the market which is now availabte In 32 cwnbim The Neon-(previous Mono%e NeON),Ne0Na2 NeoNo2 Mcial won the'In—tar RRRsss44�� AWARC-m 2013,2015 and 2016.which demorNbates LGs leaders-p and Inn-vation m the solar Industry. 10350N1GV6.Ittdd 1 M111;-1,02 PM I I L E. 02 LG35QN1CN5 Preliminary, General Data Electrical Properties(STC`) CetiPropertles(MaferaVTyp _� :Va 'YstalYnetN_type rfoda! CeQMaker _ LG35ON7GVS - —' - _.._ LG Maxtre—p-mr(Pmax)) i[Wa 3SO 60Ce1'4(Gx10) PdPPVoltnge(Vmpp) ! M 353 Numberaf8ustras -22„A -. MAP Cument(ImpP) — [A]i 9.92 Maduia D(mentiorc x W x H -------- -(L ) 1,666mmx t,plGmmxdO rnm Open Coait Voltage Noe 5%) [V) A1.3 .�.__....—__..._..____..„,... 171 kg _ ShaK Grcuit CLrrcnt(Isc,_SX) [A] 10.61 G1ass'(Materat) ____•_ ..._--__._._ Tempered Glass Wth AR CaaUng. x&toduh fiffiacncy {96] 20.4 Backshec;(Cator} Po—Tol White _'— .--.•.••." '— erance 0-43 Frarne(Matena0------_.-_. Anodized Now— AM 15,MeasuteTa e—s 3% Lmctian 8ax(ProtecCton 0e4rca}..`._�`. - iP 68 wIlh 30ypass Qiades cmtesttcngm)^ .._v.___.._.__.__ 1,ODpmmx2EF —�--- Operat)ngCond'rtiarls Cannaetor(Type(IU4eWv) MC4/MC Operat g Tempemt— .[°C) _ -40- 90 _ system Certifications and Warranty r`°m n"n sa es r.:e rratmg [A] 20 ._-. Meth NofTes•.raad'(Frortt) '_[Pa/p5ff _S,d00/713 IECG721 S-rl-7-7f2:2076,IEC 51730-l12201b MetlsaNmtTest lnad'(Rear] �-_(Patpsf]_'•_ - -�-^- 4,0pp1B4 -- - certifications — w 900t,rso 74001.1SO 50001 --_ •lAechanlol Test Load,SR00 Paid.000 Pa hazed on IEC 61215.2:2016(Test lnod- L.M.--.y-- Oli5A51B001 Factor(t5)) Daslin Safety 'SaltA tc..m IDDTast I[C 6170t,76t7 t+'.'"rlty" AntntanlaC rasinnTest IEC 5271 G;2013 Packaging Configuration Fire RaOn^ _ - - Class C(UL 790) Number of Modules per Pallet [EA] _ 25' Solar Modulo Pr.duct%y.ranty 25 Years Number of Maduies per 40ftH4 Container {EA] 550 Solar ModuL Output Warranty _ Uaear Warranty —_--- Packt961g Bax_0.'mms7ans(Lx V{x N) -; [mm] —__1,7SO x 7,120 x 7,221 —, Mmprosed;7sx year 96%Qhom2-24thyeu:433%fyeardmvlaftcr 25th}wr.90.06X -- Packaging B-ox Gm55 Weight_- .__D�] .__._464.__._ Temperature.Characteristics Dimensions(mminch) — NMOT" 42 t 3 -� Pmex WC]. -036 .Vac—....__._.__..-_---- [M+'c7 -0.27 tma.ao.o pun •NYAriNommalModzkO ifn.T .. ." P� 9�rrpemturekhradiana:B00Wfm2Aadkmtemperanus20'C � tzxr«r ,... r .ae.a o. .sm Whd speed?naRSpzctnmrA?A SS \ j _ ciao•» f f I ElecMcal-_Properties Mader. U335cN1c-US I . Maxknunl Power(Pmax) F _ 261 MPPVoltage(VmpP) ! [V] 33A MPPcwTmt(l.pP) [A] —•.��`M 7s7 , Open Graft Voltage Nae)i [V] 3880 Sh —r-- aKC7lakNrrent(Isc) [A] -_•4 U53 -� I-V Curves t o l MOM - aoun arxN/ � i _i 20n 30,0 40.o Vologe(V) Saa,=siness tnc cb Product saaMcaticnsare subject to thangev rtriaut naam ■sw`� Solo-Business Dr.en LG350N7C-VS_AUS.adf L ^� 200o ire,ILk 006 ■��aaasss',Mss Lincolnshire,IL 60069 Life'sGooi u(g_saiarcam 02019LGElettmni¢Nd rights reserved, �- 'LQMN,PV3JrWd 2 . ! 697119 1A2PA1) Sheet Enphase-Microinverters ,r 14 -Enphase The high-powered smart grid-ready The lQ 7 Micro`and Enphase.10 7+Micro u IQ 7 dramatically simplify the installation process_while a achieving the highest system efficiency. . croinverters Part of the Enphase IQ System;the-IQ 7 and IQ 7+Micrdinverters.integrate.with the Enphase IQ Envoy.m,.Enphase IQ.BatteryTM,and the-Enphase Enlighten" monitoring and analysis.software. IQ Series.Microinverters extend the reliability. :standards set forth.by previous generations and'. undergo over a million hours of power-on testing, enabling Enphaseto.provide.an industry-leading warranty.of up to-25.years. Easy,to-Install -�" Lightweight and simpie Faster.installation with Improved,lighter.two-wire cabling i—iuii'� s • Built-in rapid shutdown compliant(NEC 2014&2017) 'Productive and Reliable. • Optimized for high powered 60-cell and-72-cell*modules • More than a million hours of testing • Class ll.double-insulated enclosure f • UL listed m Smart Grid Ready • Compiles with advanced grid support,voltage and frequency ride-through requirements • Remotely updates to respond to changing- __ __ .. grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) �t *The IQ 7+Micro-Is required to.support-72-cell.modules. To learn more about Enphase offerings,visit enphase.com uEMI Fs HAS-E. . 'Enphase lQ 7 and iQ 7+ Microinverters INPUT DATA(DC) •IQ7-60-2-US'/IQ7-60-8-US IQ7PLUS-72-2-US/I07PLUS-72=B-US Commonly used module pairings' 235 W-350.W+ 235 W 440 W+ -� Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37.V 27-V-45 V Operating range 16 V-48 V 16 V-60'V Min/Max start voltage 22 V/-48 V 22 V/60 V Max DC short circuit current(module.lsc) 15 A 15A Overvoltage class DC.port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection.requires.max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter AQ 7+Mlcroinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L).voltage/rangez 240 V/ 208 V7 240 V/ 20B V/ 211-264.V 183-229 V 211-264 V 183-229 V Maximum continuous outputcurrent 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault currentover3.cycles 5:8Arms 5.8Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC)' 13_(208-VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC.port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1;0 Power factor(adjustable) 0.7leading...0.7lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.6% MECHANICAL.DATA ---; -- ---- - 0 0 AmbienYtemperature range 40 C to+fi5 C Relative humidity range 4%to 100%'(condensing) Connector type(IQ7-60-2-US&_IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX.with ad'ditlonal.Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS-727B-1JS) Friends PV2.(MC4 Inter m ateab le).. Adaptors for modules with MC4 or UTX connectors: PV2 to MC4-.'Order ECA=S20-S22 PV2 to UTX:order ECA-S20-'S25 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without.bracket) Weight 1;08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-Insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) _ Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The-AC and DC.connectors.have been evaluated and approved by UL for.use as the'load-break disconnect required by NEC 690. Compliance CA Rule 21'(UL 174.1-SA) UL 62109-1,UL1741/IEEE1547,FCC.Part 15 Class B, ICES-0003 Class B; CAN/CSA-C22:2.N0.107.1-01 This product Is UL Listed as PV Rapid Shut Down Equipment and conforms wfth NEC-2014 and NEC-2017 section 690.12 and.C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC .and DC conductors,when.lnstalled according manufacturer's instructions. 1.No enforced DC/AC ratio:Seethe compatibility calculator at httos://ennhase.com/en-us/support/module-com atihility 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits tray vary.Refer to local requirements to define the number of microinverters per branch in your area. To(earn more about Enphase.offerings,visit enphase.com w EfV PHAS E ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018:05-24 Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman, NJ. 08558 908-872-3664 January 29, 2018 Building Department Attn: Plan Reviewer Re:Proposed Photovoltaic Solar Panel Installation Dear Sir: I have reviewed the following documents related to the"EcoFasten Solar"ROCK-IT SYSTEM 4.0 and certify that the attachment system when installed in strict compliance with the manufacturers Installation Manual appropriate for this application and is in compliance with the latest building codes including Florida Administrative Code, 2017 Florida Building Code -Residential Sixth Edition, ASCE-7-10, 2017 Florida Building Code—Energy Conservation, Sixth Edition, 2014 National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. I make this certification for the following listed documents: 1. ROCK-IT SYSTEM 4.0 Installation Manual 2. PZSE,Inc Structural Engineers Certification. 3. EcoFasten Solar Certificate No. US 82150026 4. ROCK-IT SYSTEM 4.0 Cut Sheet for Coupling, Hybrid Coupling, and Mount. If you have any questions relating to this matter,please contact me at your earliest convenience. Thank you. OF o . pN1EL pv :7 ••• o R98795 Jj 7; ` Daniel W. Dunzik RA. LEED-AP °° •e�� Fl. Lic.No. AR98795 AR Cut Sheet - Rock-It-4.0-Coupling e i 1. Installation to be completed in accordance with manufacturer's written specifications and installation instructions. 2. See spec sheet or contact manufacturer for detailed material,finishes,and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. ! 5. Subject to change without notice. i f I i i 3.17in ® ® ! ® ® ® [80.54mm] I i I i 7.00in [177.80mm] � I I ! F i j I t � f 2.02in I� 2.14in 2.34in l� 1 [51 .38mm] [54.37mm] [59.36mm] 32mm �35mm 40mm 4 f � I I 1 1 ! @ALPINE 4741 W Polk Stree Ste. 4 SNGUARDSjEcoI`asten Solar Phoenix,AZ 85043 j Toll Free Phone 1.888.766.4273. Toll Free Phone 1.877.859.3947 j Material:See Spec Sheet Toll Free Fax 1.888.766.9994 Toll Free Fax 1.888.766.9994 Scale: 1:4 j. 6/28/2017 j ASG: - EFS: x Cut Sheet - Rock-It-4.0-Hybrid Coupling 1. Installation to be completed in accordance with manufacturer's written specifications and installation instructions. 2. See spec sheet or contact manufacturer for detailed material,finishes, and configuration options. j 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. i i 3.16in ® ® ® 80.29mm I ; 7.00in [177.80m m] rn i m i i 5.00in [127mm] I i 2.02in 2.14in 234in I� [51 .38mm] [54.37mm] [59.36mm] 32mm �35mm 40mm ALPINE <@> N� ARI�s `OEcoFastn Sclar=''I Phoen xPAZ 85t043 Ste.4 Toll Free Phone 1.888.766.4273.� Toll Free Phone 1.877.859.3947 Material:See Spec Sheet Toll Free Fax 1.888.766.9994 Toll Free Fax 1.888.766.9994 Scale: 1:1 � 6/28/2017 ' ASG: - EFS: x i ROC K-IT SYST E M" 4.O RAIL-FREE RACKING UTII_IZ2S ECOFraSTen SOL-ars PaTenTeD TeCHnOLOGY d - A�coFasten S o ar aVA ��� ' Co.Faisten S-ol`ar@ Committed to the connection. Document Date:9.8.2017 Contents Pg. 1 ................................................................................................................................................... Assets of Design Features System Components Pg. 2. ............................................................................................................................. Rock-It 4.0 Mount Assembly Rock-It 4.0 Coupling Assembly Pg. 3 ........................................................................................................... Rock-It 4.0 Hybrid Mount Assembly. Rock-It Clip SS Assembly Rock-It Clip 2.0 Assembly Pg. 4.......................................................................................................................................................... Array Layout GreenFasten Flashing Install Pg. 5 ...................:.................................................................................................................. Rock-It System 4.0 Install Pg. 6 ...............:.................................................................................................................................. Ground Lug Install Pg. 7 ...................................:...................................................................................................... Rock-It Clip SS Install Rock-It Clip 2.0 Install Pg. 8 -12 ............................................................................................................................. Standoff Spacing Tables Snow Load 0-20 psf Snow Load 21-30 psf Snow Load 31-40 psf Snow Load 41-50 psf Snow Load 51-60 psf Pg. 13 ........................................................................................... . ........... ..................... Grounding Information Bonding Assembly and Bonding Path Pg. 14 ................................................................................................................ Thermal Expansion and Bonding Bracket Spacing Staggered Layout Cantilever Pg. 15.. . .................................................................................................................................... System Specifications Evaluated, Compatible Modules ROCK-IT SYSTeI'1"l 4.0 Designed.with the installer in mind. x ` EcoFasten Solar specializes_in solar roof attachments that are fast and easy to install,straightforward,secure and- .cost-effective.EtoFasten offers a wide variety of standard products as well as custom solutions,for a one-stop source for all of your rooftop anchoring needs: Products-are.rigorously tested and approved above and.beyond industry standards in-house and.by third party agencies.'Ecofasten's patented conical sealing system has been in service in.the:snow guard and solar.industries for two decades. FeaTu res • New and.improved design North-South adjustability • Fastest,easiest to level system on the market • Only one tool required(1/2"deep well-socket) • Integrated electrical bonding 0Vertical adjustment of 3"4' • SIMPLE-only 4 components SYSTem cam POnenTS*' reaulreD y — ' ROCK-IT SLIDe ROCK-IT 4.0 ROCK-IT 4,0 COUPLinG. ROCK-IT 4.0 4" For comp SHinGLe MounT & LOaD BearinG FOOT Array SKIrF 8" For TILe. SYSTem componenTS* - 'OPTIona-L P""" \ - QWcoFasten n��� = Solar® -cam ROCK-IT SS - (ReFer TO".PG. 6) EcoFFasten Solar products are protected bythefollowingUS.Patents: � 8,151,522 8,153,700 8,181,398.8,166,713 8,146,299 , ;U, ROCK-IT-4.0 8,209,914 8,245,454 8,272,174 8,225,557 9,010,038 ROCK-IT 4.0 fi Array SKIrT 9,134,040 9,175,478 9,212,833 HYBrID IvlOUr1T "� EnD caps n oaa� ona(ReFer TO PG: 5) arei caps come EsT ROCK-IT'CLIP 2.0 eno of sKirT secnons) (ReFer TO PG. 6) *Components for use with 32mm modules are available as special order.Components for use with 32mm modules are labeled as such on system packaging.Please refer.to.evaluated,compatible modules grid on page 15 to identify system compatible.32mm modules. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 .1 r ROCK-IT 4.0 mounT ASSemBLY NOTe: ITems 1-7 SHIP assemBL.(�-D 1 5/16"-18 x 1.75"Hex Serrated Flange Bolt 300 Series SS 2 Rock-It 4.0 Mid-Clamp 6000 Series AL 3 Rock-It 4.0 Shelf 6000 Series AL 4, 4 Flange Level Nut 300 Series SS 5 Rock-It 4.0 Tie Plate 6000 Series AL 6 Rock-It Pedestal 6000 Series AL 7 5/16"-18 x 3/8"Hex Serrated Flange Bolt 300 Series SS - 8 '3/8"ID Star Washer 300 Series SS ` 9 3/8"-16 x 3"Hex Tap Bolt 300 Series SS � tl a r ROCK-IT SLIDes are accePTaBLe BracKeTS For Use WITH ROCK-IT 4.0 (SOLD SeParaTeLY) ROCK-IT 4.0 COUPLING aSSeMBLY NOTe: ITems 1-3 SHIP assemBLeD. 1 5/16"-18 x 1.75"Hex Serrated Flange Bolt 300 Series SS 2 Rock-It 4.0 Coupling Mid-Clamp 6000 Series'AL ® 3 Rock-It 4.0 Coupling Shelf 6000 Series AL ® 4 Rock-It Load Bearing Foot Clip I 5 . Rock-It Load Bearing Foot Base I ,I, 3 A 5 www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 2 ROCK-IT 4.0 HYBRID MOl. nT ASSeMBLJ- NOTe: ITems 1-10 SHIP assemBLeD 1 Rock-It 4.0 Shelf 6000 Series AL 2 Rock-It 4.0 Coupling Mid-Clamp 6000 Series AL 2 10 3 Rock-It 4.0 Coupling Tie Pfate6000 Series AL 4 Flange Level Nut 300 Series SS ® 5 Rock-It Pedestal 6000 Series AL 6 Rock-It Slide 6000 Series AL 7 3/8"-16 x 3"Hex Tap Bolt 300 Series SS 8 3/8"ID Star Washer 300 Series S Q 3� 9 5/16"-18 x 3/8"Hex Serrated Flange Bolt 300 Series SS 4 10 5/16"-18 x 1.5"Hex Serrated Flange Bolt 300 Series SS e . 0 b 7 ROCK-IT CLIP SS ASseMBLY ROCK-IT CLIP 2.0 ASseMBLY NOTe: ITems 1-3 SHIP assemBLeD NOTe: ITems 1-3 SHIP assemBLeD 1 Stainless Steel Carriage Bolt-.313-18X.75 1 Rock-It Clip 2.0 2 Rock-It Clip SS 2 Stainless Steel Flange nut.313-18 3 Stainless Steel Flange nut.313-18 3 Bolt.3125-18x1 x1-S I � i 3 O www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 3 Arra-Y LaYOUT • Find the required structural attachment points. ` Mark these using a vertical (N-S)chalk line on the center of the rafters. • Spacing may vary depending,upon project specific structural requirements;i.e.high snow and wind load areas may require lesser bracket spacing in the E-W axis vs.the maximum spacing.Max spacing is 48"for portrait orientation and 72"for landscape orientation.Consult project layout diagram for project specific bracket spacing on the roof. • Install Rock-It Mounts to predetermined mount spacing. • The Rock-It Array Skirt-sections are the width of a typical 60 cell module—use the Rock-It Array Skirt as a guide to lay out module placement. Note:The distance between the rows of mounts is calculated by the module dimension N-S plus 1 3/8" (35mm).Lag screw should be installed as close to center of exposed shingle as possible. The minimum distance between the lag screw and the edge of the shingle is 1/2" GreenFEISTenTm FLaSHinG inSTaLL 1 Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. -2 Drill a pilot hole(1/4"diameter)for the lag bolt..Backfill with sealant.EcoFasten Solar recommends an EPDM mastic. 3 Insert the flashing so the top part is under the next row of shingles and pushed far- _ enough up slope to prevent water infiltration through vertical joint in shingles.The leading edge of flashing must butt against upper row of nails to prevent turning when torqued. 4 Line up pilot hole with GreenFasten flashing hole. Insert the lag bolt through the EPDM bonded washer,the Rock-It slide,the gasketed hole in the flashing and into the rafter: Torque:The range is between 100-140 torque inch-pounds depending on the type of wood and time of year.The visual indicator for proper.torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses.If using an-impact wrench to install the fasteners be careful not to over torque the fastener.You may need to stop and use a ratchet to finish the install. *The Engineer of Record shall check capacity of rafter to support lag screw loading. www.ecofastenso[ar.com info@ecofastensolar.com 877-859-3947 4 .ROCK-IT SY STeITI 4.O inSTaLL r' jd. .AQ Fig. A 1. Install EcoFasten Solar Flashing,with Rock-It o'unts •Follow EcoFasten Solar Install Instructions for flashing and bracket install(GreenFasten shown above).. •Optimum vertical distance between'lag bolts Is 13/8'plus,module dimension. •Set mounts on eave most row so that the Rock-It Pedestal[son the South end of Rock-It Slide. • Set mounts on all upper rows so that the Rock-it Pedestal is on the North end of Rock-It-Slide.. 2 Install Rock-It-Array Skirt onto Eave.Mounts Slide Rock-lt Array Skirt into front channel on Rock-It Shelf. Array Skirt End Caps are pre-instal led.on the East end of each skirt section,and are used to couple the skirt sections where needed(see Fig.A). • Tighten Mid-Clamp bolt,"clamping Rock-It Array Skirt to mount:Torque to 2001n4bs.(1301n-lbs.when Installing with 32mm modules). 3-4 Install Rock-It Couplings(when joining 4 panels with a Coupling,the use of a load bearing.foot is-required)- • Prior to mounting on the roof,snap Load Bearing Foot'into the bottom of Rock-it Coupling'if required. (Each Load Bearing Foot is set to same height as the Rock-It Mounts-adjust accordingly) • Oneave row only,slide Rock-It Array Skirt onto Rock-It Coupling Shelf.Torque to specified value. NOTE:If a coupling,lands on.a rafter,the Hybrid Mount*should be used in piace.of the Rock-It Coupling"(refer to Image 3a).. 'Hybrid Mount can be made in the field by assembling a coupling to a mount pedestal,or by purchasing separately. C, Align and Straighten First Row-of the Rock-It System with Rock--It-Array Skirt • Use North-South adjustment of-the Rock-It Pedestal to straighten Rock-It Array Skirt and align module with Array Skirt. •Torque screw on side of.Rock-It Pedestal to 150 in-Ibs.to secure It to the Rock-It Slide. •"Adjust Flange Level Nut to level the system(optional-can be leveled during or after installation): Install.1st Row-of PV Modules 6-9 . Slide upslope Rock-ICMounts down to engage top offirst module. • Install Rock-It Couplings on the upslope side of 1 st row of panels.. •Torque 2nd row of Mid-Clamps on Rock-It Mounts and Rock-It Couplings to specified value. • Install balance of PV modules,ensuring that the Rock-It Pedestals are in the appropriate.position,then torque Mld-Clamps to secure modules. 10 Level the Rock-It System • When assembly is complete,level the entire system by.adjusting Flange.Level Nuts(Flange Level-Nuts have no torque value). • Height between roof surface and underside of modules should be 3'or less,when Installed With Type 2 modules. INSTALLATION NOTE:Modules should be-installed so that the junction box is installed upslope;away from the leading-edge of the array. www.ecofastensolarcom info@ecofastensolar.com 877-859-3947 5 GrounDnG LUG nsTaLL =: .. Necessary Components: One of the following ground lugs (or any UL 2703 compliant ground lug): Burndy CL50-1TN Ground Lug (UL 2703-E351343 / UL 467-E9999) ILSCO SGB-4 Ground Lug (UL 2703-E354420 /UL 467-E34440) ILSCO GBL-4DBT(UL 2703-E354420 /UL 467-E34440) ILSCO GBL-4DBTH (UL 2703-E354420 /UL 467-E34440) ILSCO GBL-4SS (UL 2703-E354420 /UL 467-E34440) Note:Drill and deburr hole in Ground Lug prior to installation - 14 AWG-4 AWG Copper Ground Wire* Torque Values: - 8-32 x 0.5"Serrated Flange Head Bolt(300 Series SS) 14-10 AWG=20 in-Ibs. - 8-32 Serrated Flange Nut(300 Series SS) 8 AWG=25 in-Ibs. - 11/32"and 1/4"wrenches or ratchets/sockets 6-4 AWG=35 in-Ibs. 1 Insert the flange bolt into the module ground hole.Place Star Washer over bolt. Place ground lug over the bolt and Star Washer,and turn to desired orientation. 2 Install Flange Nut. 3 Tighten Flange Nut/Bolt. 4 Place wire in Ground Lug channel and tighten setscrew to complete assembly. *Wire should be sized in accordance with the National Electrical Code,NFPA 70,Section 690.45,and a minimum of 1/4"clearance required between bare copper wire and aluminum. Drill hole per grounding lug manufacturers i - specifications in the upslope part of Rock-It Coupling !! ' for attaching grounding lug. 1'L (Iff l II rY Note:Deburr hole in Ground Lug and Rock-It Coupling prior to installation. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 6 ROCK-IT CLIP S S- i n STa LL 0 A(uptAIP MountingLncitiom R� a -- -714in from JunctionRox 1 1 .Locate all parts -Locate the Rock-It Clip SS,micro-inverter/power optimizer,and the section of the module frame in which you will be mounting the micro-inverter/power optimizer. See fig.A for acceptable mounting locations. 2 Install the Rock-It Clip SS • Slide the Rock-It Clip SS onto the:lip of the module frame. • Slide.the micro-inverter/power optimizer into the.opposite lip of.the Rock-It Clip:55. • Tighten the bolt to 150 in-lb minumum to clamp the Rock-It Clip SS to the module frame and the micro-inverter/power optimizer to the Rock-it Clip SS. • Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power optimizer flange is tight against the clip flange to avoid rotation during tightening. ROCK-IT CLIP 2.0 inSTaLL Inverter Flange - t Module Frame Rock-It-Clip 2.0 1 Locate all parts -Locate the Rock-It-Clip 2.0,micro-inverter/power optimizer,and the section of the module frame in which you will be mounting the micro-inverter/power optimizer. 2 Install.the Rock-It Clip 2.0(See below detail) • Slide the Rock-It Clip 2.0 onto the-lip of the micro-inverter/power optimizer. • Slide the micro-inverter/power optimizer into the opposite lip of the module frame: • Tighten the bolt to 150 in-lb to clamp the Rock-It Clip 2.0 to the module frame and the micro-inverter/power optimizer to the Rock-It Clip 2.0. • Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power optimizer flange is tight against the clip flange to avoid rotation during tightening.. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 7 Snow Load 0-20 psf Modules in Landscape Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 ASCE 7-05 ASCE 7-10 Cate o Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 159 93 59 85 mph 110 mph C 114 67 42 88 88 D 96_ _ 56 35 91 74 74 B 146 _ 85 54 90 mph 115 mph C 104 61 38 98 80 80 D 88 _ 51 32 83 68- 68 B 123 72 45 95 �95 100 mph 125 mph C 88 51 32 83 68 68 D 74 "43 27 70 , 57 57 B----- ---98-� �-67 _ -'36`- --------93-- -----76---- —_76 110 mph . 140 mph C 70 41 26 66 54 54 D 59 34 22 56 46 _ 46 B 85 50 31 81 66 66 120 mph 150 mph C 61 36 22 58 47 47 D 51 30 19 49 40 40 . Notes: Spacing Governed by Snow Load 1:)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafterspacing 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module width of 40" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is included in this table Snow Load 0-20 psf Wind Speed Exposure 2.12<Roof Pitch'<6:12 7:12<Roof Pitch<1.2:12 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1. Zone 2 ,Zone 3 B 91 53 33 85 mph 110 mph C 65 38 24 61 50 50 D 55 32 20 52 42 42 B 83 49 30 90 mph 115 mph -C 59i 35 22. 56 46 46 D 50 29 18 47 38 �541 B 70 41 26 54 100 mph 125 mph C 50 29 18 47 39 39 D 42 26 15 40 32 32 B 56 33 20 53 43 43 110 mph 140 mph . C 40, 23 14 38 31 31 D 34, 19 12 32 26 26 B 49 28 18 46 37 37 120 mph 150 mph C 35 20 12 33 27 27 D 29 17 10 28 22 22 Notes: -Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5-)Values based on a maximum module length of 70" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is included in this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 8 Snow Load 21-30 psf Modules in Landscape Wind Speed Exposure 2:12 <Roof Pitch <6:12 7:12<Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 10 93 59 8 8 68 85 mph 110 mph C 110 67 42 68 68 68 D 96 56 35 68 68 68 B 110 85 54 8 6'- 68 90 mph 115 mph C 104 61 38 6-8 68 D 88 51 32 _ 68 6 68 B 10 72 45 68 '8 6 100 mph 125 mph C 88 51 32 D 74 43' 27 68 57 57 B 98 57 36 EWE= 110 mph 140 mph C 70 41 26 66 54 54 D 59 34 22 56 46 46 B 85 �50_-- - 31 68 66 66 120 mph 150 mph C 61 36 22 58 47 47 D 51 30 19 49 40 40 Notes: ®Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafterspacing 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module width of 40" 6.)Based on Risk Category II (ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1. No site specific engineering is included in this table Snow Load 21-30 psf Wind Speed Exposure 2:12< Roof Pitch <6:12 7:12 < Roof Pitch <12,12 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone,2 Zone 3 -------- -�-^ B 53-----33 — 85 mph 110 mph C 65 38 24 D 55 32 20 B - 49 -- 30 90 mph 115 mph C 59 35 22 D 50 29 _ 18 38 38 100 mph 125 mph C 50 29 18 39 39 D 42 26 15 40 32 32 - --- - - B - -"56-- -----33- - -- - -20 - - 110 mph 140 mph C 40 23 14 38 31 31 D 34 19 __ 12 _ 32 26 26 B 49 28 18 37 37 120 mph 150 mph C 35 20 12 33 27 27 D 29 17 10 28 22 22 Notes: ®Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module length of 70" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is included in this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 9 Snow Load 31-40 psf Modules in Landscape Wind Speed Exposure 2:12< Roof Pitch <6:12 7:12<Roof Pitch<12:12. ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 83 8r3 59 5 513 8 85 mph 110 mph C 8 67 42 D_ 8 56 35 1 B 8a.- 83 54 5 5 1 90 mph 115 mph C 61 38 5 D 8� 51 32 100 mph 125 mph C 83 51 '32 1 D 74 43 27 1 B 8 57 36 110 mph 140 mph C 70 41 26 5 D 59 34 22 1 46 46 120 mph 150 mph C 61 •36 22 51 47 47 D 51 30 19 49• 40 40 Notes: ®Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafterspacing 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module width of 40" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1. No site specific engineering is included in this table Snow Load 31-40 psf Wind Speed Exposure 2:12< Roof Pitch <6:12 7:12<Roof Pitch<12:12 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 33 85 mph 110 mph C 38 24 --- - - -- .---D - --- -- -32- - -- _20 - B 49 30 90 mph 115 mph C 35 22 D 29 18 ----'- � B - �41 26 100 mph 125 mph C 29 18 D 42 26 _ 15 110 mph 140 mph C 40 23 14 D 34 _ 19 12 26 26 B 49 28 18 120 mph 150 mph C 35 20 12 27 27 D 29 17 10 28 22 22 Notes: -Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module length of 70" 6.)Based on Risk Category II (ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is included in this table www.ecofastensolar.com info@ecofastensolar.com 1 877-859-3947 10 Snow Load 41-50 psf Modules in Landscape Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 ASCE 7-05 ASCE 7-10. Category Zone 1 Zone 2 Zone 3 Zone 1 .. Zone 2 Zone 3 B 66 66 59 5 85 mph 110 mph C 66 66 42 51 5 D. 66 56 35 1 ----- -- -- - -- --- ----- B_-- - 66 66 54 51 5 5 66 90 mph 115 mph C 66 61 38 5 D 51 32 5 5 - - - - - - -.- - - B- 66 66 --45 - 5 100 mph 125 mph C 66 51 32 51 D 66 43 27 5 N. B 66 57 36 5 110 mph 140 mph C 66 41 26 51 D 59 34 22 5 46 46 120 mph 150 mph C 61 36 22 51 47 47 D 51 30 19 49 40 40 Notes: Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafterspacing 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module width of 40" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is included in this table Snow Load 41-50 psf Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 ASCE_7_-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 33 85 mph 110 mph C 38 24 D 32 20 B 30 90 mph 115 mph C 35 22 D 29 18 - - —_--- -B 26 100 mph 125 mph C 29 18 D 26 15 B 33 20 110 mph 140 mph C 23 14 D 19 12 - — - ---- -B---- — 28 18-- 120 mph 150 mph C 35 20 12 D 29 17 10 22 22 Notes: Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module length of 70" 6.)Based on Risk Category If(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is included in this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 11 Snow Load 51-60 psf ` Modules in Landscape Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 ASCE 7-05 ASCE 7-10' . CategoryZone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 B 5'• 5T5 5r5 3T 4 3' 85 mph 110 mph " C 55 55 42 34 34 4 D 5'5 55 35. 34 34 B 55 5 54 34 34 4 90 mph 115 mph C 55 55 38 4 3 4 D 5 51 32 34 34 34 B 55 55 45 34 34 34 100 mph 125 mph C 55 51 32 34 3 34 D 55 43 27 34 4 B 5• 55 36 34 34 110 mph 140 mph C 55 41 26 4 34 4 D 55 34 22 4 34 - --- - - - ——— B --- 55 —-50— -- 31 3-4 4 34 120 mph 150 mph C 55 36 22 34 34 D 51 30 1 19 34 3 3 Notes: ®Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, however the designer must round down to meet appropriate rafterspacing 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module width of 40" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is included in this table Snow Load 51-60 psf Wind Speed Exposure 2:12<Roof Pitch<6:12 7:12<Roof Pitch<12:12 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 85 mph 110 mph C 24 D_ 32 20- B 30 90 mph 115 mph C 22 D 29 18 B 26 100 mph 125 mph C 29 18 D 26 15 110 mph 140 mph C 23 14 D 19 _ 12 --- —'-- B--- — 28 18 120 mph 150 mph C 20 12 D 29 17 10 Notes: ,-Spacing Governed by Snow Load 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" 3.)Maximum allowed standoff capcity=547#(per testing results) 4.)Includes additional factor of safety of 1.5 for lag pullout capacity 5.)Values based on a maximum module length of 70" 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height 7.)All adjustment factors are set to 1.No site specific engineering is included in this table www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 12 GrounDinG inFormaTion The rail-free Rock-It System maybe used to mount and ground PV modules that comply with UL 1703,only when that specific module has been evaluated for mounting and grounding,in compliance with the included installation instructions. Note:Grounding lug must be visible to inspectors from the entire perimeter of the PV array. Multiple Use Grounding Pins Grounding pins within the Mid-Clamp are multiple use bonding/grounding devices.Modules will need to be adjusted if the Mid-Clamps are loosened to ensure there is"new"metal to pierce into upon retightening. Grounding Method Rock'-It 4.0 Mount bonds N-S rows of modules Rock-It 4.0 Coupling bonds E-W rows of modules Rock-It Array Skirt bonds E-W along the entire array when installed One Burndy CL50-1TN ground lug is required per PV array,limited to 300 modules placed in either portrait or landscape orientation. BonDinG AssemBL-Y anD BonDinG PATH Bond Path •�'Grounding Lug Conductor Grounding Integrated Bonding �-Conductor Grou - genera0ytoearth ground w Rock-It Coupling ■ Rock-It Mount d Rock-It ArraySklrt i Bond Path I 'Bond Path Grounding Lug '0 Grounding Lug Equipment Grounding �—Conductor(EGCJ- �—Equipment Grounding gcrxrally to.a th Conductor(EGC)n pound g.ntrally to.erth - grouttd Rock.lt Coupling Rock-I[Coupling 0,Rock-lt Mount ®Rock-It Array Skirt m Rock-It Maunt Rock-it Array Skirt www.ecofastensolar.com. info@ecofastensolar.com 877-859-3947 13 THermaL Expansion anD BonDi.nG JL A thermal expansion gap is required per each.continuous 40'length of modules. Bond Path Grounding Lug Omit-a coupling and leave a 2"gap in .the Rock-It Array Skirt and also-between / —Equipment ooruiducte�t(EGQ-ding generally to earth. the modules at:that point. ground Rock-It Coupling ■ Rock-It Mount If e —Rock-It Array Skirt BracKeT sPacinG Portrait Orientation Landscape Orientation Maximum east/west bracket spacing is 48"OC. Max east/west bracket spacing is 72"OC. 32mm modules:Max east/west bracket spacing is 48"OC. Spacing may vary depending upon project specific structural requirements,i.e.high snow and wind load areas may require lesser spacing E-W than the maximum. sTaGGereD LagOUT canTILever anD OFFseT Staggered Mounting Points Cantilever Offset �► .Rock-It Mount _Rock-It Coupling Cantilever: Maximum cantilever is 1/3 bracket spacing. For portrait orientation installations,check layout prior to installing. The.array layout instructions in this installation manual offer a general overview of layout. Periodically;due to a variety of Offset: Offset from all roof edges depends on wind speed,snow factors(roof obstacles,shading,etc.)other.layouts are required. loads,local fire and building codes.per location www.-ecofastensolar.com info@ecofastensolar.com 877-859-3947 14 ROCK- IT S Y STe M 4.0 sYSTem sPecIFIcaTions Max No.of Panels 300 Modules per ground lug Materials 300 Series Stainless, 6000 Series Aluminum Max System Voltage 1000VDC Coating BlackAndodization/Mill Finish Class A Fire.Rating With UL1703 Type 1 Rated Lug Specifications. Burndy CL50-1TN.Ground Lug Modules;see note below. .(UL Listing#KDER E9999) Leveling Range 3-4" Ground Wire 14 AWG-4 AWG Copper Per above Lug spec. Ground Wire Rock-It Slide Comp Range 3" Max Module Size 64.96"(1650mm)x Rock-It Slide Tile T' 39.05"(992mm)x 2"(50mm) Min/Max Roof Slope 1/2:12/12:12 Max Downforce/Uplift Rating 45-PSF Max Anchor Spacing(35mm/40mm) .72" Rock-It Mount Load Rating 547lbs with Single 5/16"Lag 3.0 Max Anchor Spacing(32mm) 48" Safety Factor Skirt Box QTY 6 units Slide Fastening Hole 5/16"diameter Mount Box QTY 1.2 units Module Cantilever Maximum cantilever is 1/3 Rock-It Slide Box QTY 50 units bracket spacing Coupling Box QTY 12 units Warranty 1.20Year Material and Workman- ship Codes:National Electric Code,ANSI/NFPA.70,NEC 250;NEC 690,IRC;IBC Standards:UL 2703:First Edition,UL 1703 ,pt, �,'BF.coF.+,t.S.tur L[oliutcn$O�aY ROCK IT SYSTEM ROpKK�,naSTEM MFG IO CODE OGT.Q2-7016 CONFORMSTO UL7F07 CONFORMS TOUL2703 lOM G1P'4 YCix5TAWTKM ,savv�-n WNWLiOxI"MWlP1G5 ....-.._.-.O /Ssoal>•�vmm scicau uoDut£5 The EcoFasten Solar Rock-It System is a rooftop PV racking system consisting of 6000 Series Aluminum and 300 Series Stainless Steel components.The Rock-It System includes the rack components but does not include the PV. panels, inverters or electrical components.The PV modules to be used with Rock-It shall be certified under UL.1703.The system shall be used on steep slope roofs mounted over a Class A-fire rated roofing material and attached to the roof structure using 5/16"diameter,minimum 4"long 300 series Stainless Steel:lag bolts with minimum thread embedment depth of 21/2"into the roof structure. Periodic re-inspection for loose components The system is subject tore-inspection.as required by the PV module manufacturer or by the Authority Having Jurisdiction._Re-inspection,as required,should include evaluation of any loose components or loose fasteners.All loose components and fasteners should be secured in accordance with these instructions.The system should also be evaluated for any evidence of.corrosion.Any corrosion should be removed.Any affected part should be cleaned.or replaced in accordance with these instructions. P®a 'a v EeoFasten Solar' www.ecofastensolar.com info@ecofastensolar.com :877=859-3947 15 A a FeaTures • New and.improved design •. North-South'adjustability • Fastest;easiest to level system on the market Only one tool required.(1%2"deep well socket) • Integrated electrical bonding •- Vertical adjustment of3"-4" • SIMPLE-only 4 components EvaLuaTeD, compaTIBLe MODULes Module Manufacturer Model Type CY'usecito Module Dim ensens(mm) Module Dimensions(In) -Downward Pressure Upward Pressure Doyen-slope Design Maximum damp Indicate.variabietest) Design Load(psf) -Design Load(k. Load(psf) $dmum(In) Trina Solar TSM-xxx4PX05.08 1640x992x40- 64.95"49.05"x1.57" 33.3 -33.3 20 72 Canadian Solar CSGP.-xxxM 1638 x922 x40 64.48:'x38.66"x1.57" 33.3 33.3 20 72 Canadian Solar CSGP-xxxP 1638x982x40 64.5"x38.7"x1,57" 33.3 33.3 20 72 Jlnko Solar JKM-xxxP-60 1650 x 992 x 40 64.96"x39.0 VA.57" 30 30 20 72 Jlnko Solar JKMxxxW60 1650 x992 x40 64.96"x39,05"x1.57" 30 30 :20 72 JlnkoSolar JINXXXPP-60 1650x992x40- 64.96"x39A5"x1.57" 30 30 20. 72 Jlnko Solar JIW XXXMM-60. 1650 x 992 x 40. 64.96"x39.05"x1.57" 30 30 20 72 Ming]ISolar YL2xxP-29b 1650 x990 x40 64.96"48.97'x1.57" 30 30 20 72 LG Elcetronics. LG3001`dGB3 1640 x 1000 x 35 164.57"x39.37'x1.38" 30' 30 20, 72': LG Elcetronics LG300N1K-G4 1640 x 1000 x 40 64.57"49.37'd-.57" 30 .30 :20 . 72 Axitec Solar AC-xxxM/156.60S 1640 x992 x40 64.5"x39:06'.k1.38" 30 30 20 .48. RECOM RCM-2xx-6MB 1640 x992 x35 64.56"x39.05"x1.37" 30, 30 20 72 Sllfab SLA2xicP 1650.x990 x38 i64.96"x3B.9T'x1:49" 30 30 20 72 Solaria 'PowerXr xxxR-BX '1621 x 1056 x 40 '63.89"01.53"x1:57" -.30 30 20 48- Hanwha-Q calls* Q.PRO G42xx 1670 x 1000 x 32 65.75"49.3TNI.25" 30. 30 .20 48- Hanwha-Q calls* 0,PRO.G42xx 1670 x 1000 x 32: 65.75"49,37'x1.25" 30 30 20 72 Sunpreme GxB-3xxT 1670 x997.x40 65;75"x39,25"x1.57" 30 30 20 48 REC' REC-xxx-6MB 1675 x997,x38 65.94"x39.25"x1.5" 20' 20 20. 72. REC REC-xxx-6MB 1675x997x38 65.94"x39.25"x1.5 30 30 20 48 SolarWodd. SW xxx Mono Blade 1675 x 961 x 33 65.95"x37.8':x1.30" 20 20. '20 72 SolarWddd Sw xxx Mono Black .1675x961.x33 65.95"x37.8"x1.30" 30 30 .20 .48 •Hanwha Q-Cells 32mm modules to be used with special order Rock-It System components.Call foe details. AAA: ®V.EcoFasten Solar®. www.ecofastensolarcom info@ecofastensolar.com 877-8597-3947 16 Cut Sheet,- Rock-It-4.0-Mount j1. Installation to be completed in accordance with manufacturer's written specifications and installation instructions. 2. See spec sheet or contact manufacturer for detailed material,finishes, and configuration options. 1 f 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. I ® 1 O i j ; i 3.17in [80.54mm] 2.50in [63.50 m m] f i I i �II i 1 1 i { 7 O i a o o o 2.02in 2.14in 2.34in [51 .38mm] [54.37rnm] [59.36mm] I 32mm 35mm 40mm I i '� *EALPINE ' coFasten Solaro 4741 W Polk Street Ste.4 SNGIJARDS` Phoenix,AZ 85043 j Toll Free Phone 1.888.766.4273 Toll Free Phone 1.877.859.3947 (Material:See Spec Sheet Toll Free Fax 1.888.766.9994 Toll Free Fax 1.888.766.9994 �,� �_ , Scab e: 1:2 ;6/28/2017 � A$G: - EF$: X Data Sheet Enphase Networking Enphase The Enphase'IQ.Combiner,3" with Enphase IQ Envoy' consolidates iliterconnection IQ ®IYIbll1el° 3 equipment into a single enclosure and (MlID-AM1-240-3) streamlines PV and storage installations by providing:a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart Includes IQ Envoy for communication i and control ! Flexible networking supports Wi-Fi, 1_1� Ethernet,or cellular Optional AC receptacle available for PLC LI k : — 4 bridge IA o Provides-proddction metering and optional consumption monitoring Simple 6 Reduced size from previous combiner i • Centered mounting brackets support single stud mounting 1 � Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in.breakers(not included) 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA.type 3R enclosure U� • Five-year warranty UL listed LISTED � E N P H A SE. To learn more.about Enphase offerings,visit enphase.com O./ Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy"printed circuit board for integrated revenue grade PV production metering(ANSI C12.20_+/-0.5%).and optional*consumption monitoring(+/-2.5%). ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Enphase Mobile Connect" CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1(4G based LTE-M/5-year data plan) where there,is adequate cellular service in the installation area.) Consumption Monitoring*CT CT-200-SPLIT Split core current transformers enable whole home.consumption metering(+/-2.551°). Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers.. BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton B9215 'BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VA6,.60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only'(not.included). Max.continuous current rating(input from PV) 64 A Max.total branch circuit breaker rating(input) 80Aof distributed generation/90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets).: Weight 7.5 kg(16.5 Ibs) Ambient temperature range -40°C to+460 C(-40°to-1151 F) Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20 Ato 50 A breaker inputs: 14to 4AW.G copper conductors • 60 A breaker-branch input: 4 to 1/0 AWG copper conductors • Main lug combined output:.10 to 2/0 AWG.copper.conductors -'Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing.- Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet Optional,802.'3;.Cat5E(or Cat 6)-UTP Ethernet cable (not included) Cellular Optional,CELLMODEM-0.1 (3G)or CELLMODEM-03(4G) or CELLMODEM-M1(4G based LTE-M) (not included) COMPLIANCE Compliance,Combiner UL 1741 CAN/CSA C22.2 No.107.1 47 CFR,Part 15,Class B,ICES 003' Production metering:ANSI C12.20 accuracy class 0.5(PV production) Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010=1 *Consumption monitoring is required for-Enphase Storage Systems. To learn more about Enphase offerings,visit enphase.com /� `, ©2018 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. E N P H A J E. 2018-09-13 `� Installation Manual: Soltection RJw1 Rooftop Solar Junction Box Flashing Unit For Composition/Asphalt Shingle Roofs v F. Manufactured by: Soltection: a division of Vynckier Enclosure Systems, Inc. 271 McCarty Street Houston,TX 77029 1-866-227-0577 www.soltection.com Soltection RJ-1 Installation Manual Page 1 c TABLE OF CONTENTS INSTALLATION INSTRUCTIONS Contents IMPORTANT SAFETY INSTRUCTIONS........................................................................................................................4 SAFETY WARNINGS &CAUTIONS .....................................................................................................................:....4 ELECTRICALPRECAUTIONS....................................................................................................................................5 MECHANICALPRECAUTIONS..................................................................................................................................5 PRODUCTINFORMATION.............................................................................................................................................. 6 OVERVIEW...................................................................................................................................................................... 6 PREP & PLACEMENT...................................................................................................................................................... 7 REQUIREDTOOLS.......................................................................................................................................................7 PRODUCT PLACEMENT..............................................................................................................................................7 SPECIFICATIONS .......................................................................................................................................................... 11 MECHANICAL/ELECTRICAL................................................................................................................................... 11 TORQUERATINGS..................................................................................................................................................... 11 WARRANTIES: Seller warrants to Buyer that products and any services furnished hereunder will be free from defects in material,workmanship and title and will be of the kind and quality specified in Seller's written quotation.The foregoing shall apply only to failures to meet said warranties (excluding any defects in title)which appear within two years from the date of shipment hereunder. The conditions of any tests shall be mutually agreed upon and Seller shall be notified of, and may be represented at, all tests that may be made.The warranties and remedies set forth herein are conditioned upon (a)proper storage,.installation, use and maintenance, and conformance with any applicable recommendations of Seller and (b) Buyer promptly notifying Seller of any defects and, if required, promptly making the product available for correction. If any product of service fails to meet the foregoing warranties(except title), Seller shall thereupon correct any such failure either at its option, (i)by repairing any defective or damaged part or parts of the products,or(ii)by making available, F.O.B. Seller's plant or other point of shipment, any necessary repaired or replacement parts.Where a failure cannot be corrected by Seller's reasonable efforts, the parties will negotiate an equitable adjustment in price. The preceding paragraph sets forth the exclusive remedies for claims (except as to title) based on defect in or failure of products or services;whether the claim is in contract, indemnity,warranty,tort(including Seller's negligence), strict'liability or otherwise and however instituted. Upon the expiration of the warranty period, all such liability shall terminate and Buyer shall have a reasonable time,within thirty days after the warranty period,to give written notice of any defects which appeared during the warranty period. Except as set forth in Article 2, "Patents," the foregoing warranties are exclusive and in lieu of all other warranties, whether written, oral, implied or statutory. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE SHALL APPLY. Seller does not warrant any products or services of others which Buyer has designated. www.soltection.com Soltection RJ-1 Installation Manual Page 3 IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS ; SAFETY WARNINGS PRIOR TO INSTALLATION NOTE: SAVE THESE INSTRUCTIONS This manual contains important instructions that shall be followed during.installation and maintenance of.the Soltection RJ-1 rooftop junction box with flashing. -LETHAL VOLTAGES ARE PRESENT DURING THE INSTALLATION;OPERATION AND SERVICE OF THIS EQUIPMENT.. PROPER PRECAUTIONS MUST BETAKEN AT ALL TIMES TO ENSURE THE.SAFETY OF THE SERVICE PERSONNEL.. . SAFETY WARNINGS & CAUTIONS Only.qualified personnel or licensed electricians should install this product and the instructions herein are provided for those individual(s)only. ■ To reduce the risk of.electric .shock, injury, .or death, all.electrical wiring and connections must be performed by-qualified personnel. ■ Lethal voltages are present during the installation, operation, and-servicing of this equipment. Proper precautions.must be taken at all times to ensure the safety of the service personnel. ■ Follow state and federal Occupational Safety and Health Administration (OSHA) -guidelines and regulations when-installing this.product. ■ Utilize proper Personal Protective Equipment(PPE)as required per national and local regulations as well as for installation best practices. ■ Install this apparatus in accordance with ANSI/NFPA 70, National Electrical Code (NEC). Follow all national or local electrical codes. ■ Install, operate, and use this product in a..manner consistent with,.the instructions provided..Failure to follow the procedures indicated may result in roof leaks, property damage, or consequential damage. www.soltection.com Soltection RJ-1 Installation Manual Page 4 00, 04A.WUNNIN, ELECTRICAL PRECAUTIONS ■ Ensure all electrical conductors are.at zero voltage potential:before installing or servicing this unit. ■ Never break contact on a circuit without using the appropriate disconnect device. ■ Follow established-lockout and tagout procedures for all electrical conductors prior to servicing. ■ Beware of power lines in.the vicinity of the roof, where inadvertent contact may result in electrocution, personal injury, or.death. ■ When disconnecting,source.or supply circuits, provide sufficient time.as stated in the.power-electronics manufacturer's instruction manual in order to..ensure discharge of all conductors in the circuit. • Always verify the integrity and proper installation of the electrical components prior to energizing electrical circuits. ■ Non-metallic enclosures do not provide grounding means between conduit connections. The use of grounding hubs and jumper wires are required. ■ Grounding must be sized per NEC requirements, and is the responsibility of the installer. MECHANICAL PRECAUTIONS ■ When drilling into an attic space, ensure that electrical wires, mechanical obstructions, or potential electrical hazards are removed from the vicinity and direction of the drill. ■ Do not install -if the roof is wet, frosted, or covered by ice or snow. ■_ If any part of this product becomes damaged, • remove and.destroy the entirety of-the unit. Failure to do so, may result in fire; property damage, personal injury, electrocution, or death. ■ Do not use the product to anchor fall protection equipment. www.soltection.com Soltection RJA Installation Manual Page 5. PRODUCT INFORMATION OVERVIEW ■ The Soltection RJ-1 Residential Rooftop Junction Box is a flashed roof penetration designed to protect electrical conductors entering the rooftop/attic. It is made of a high-strength UV-resistant and UV- stabilized polymeric material. ■ The RJA enclosures comes fully equipped with a slotted DIN rail mounted inside the enclosure designed for mounting of DIN rail accessories, such as terminal blocks. ■ A four position ground bar is also provided as a means to form a bond between the solar array mounted on the roof and the building. CORNER SCREWS MOLDED COVER PLASTIC SCREW FOR GROUND BAR AFFIXING DIN RAIL GROUND BAR 0 0 00 0 MOLDED BASE DIN RAIL www.soltection.com Soltection RJ-1 Installation Manual Page 6 PREP & PLACEMENT REQUIRED TOOLS ✓ Shingle IZpper Bar ✓ #2 Phillips Screwdriver ✓ Lumber Crayon ✓ Uni-Bit ✓ Hole Saw or Spade Bit ✓ Utility Knife ✓ Roofing Sealant RAFTER-_', - -- PRODUCT PLACEMENT -- - • Identify the location and placement.of the - flashing on the roof as shown. The product may be mounted beneath the array or adjacent to the array. - - v DO NOT LOCATE THE PRODUCT DIRECTLY OVERA RAFTER TO ENSURE THE RAFTER DOES NOT INTERFERE WITH THE WIRING -Remove template from packaging ENTRY INTO THE_ATTIC and use in Step.2 STEP 1 www.soltection.com Soltection RJ-1 Installation Manual Page 7 4=u'�• �',y�-,''�.'�y� fr`"<;`i�'� tea' .� ;,,;' �``4+��`�y•`a?'`-:.: i�?vLt pal ".� •1�+" , L' �� 3 � ,�''cj+". Wit.:='�:-•' Position the top edge of the template 1/2" Trace and continue using a lumber crayon to the above the 1st course of shingle as shown. bottom of the 2nd course. Cut along lines and remove shingles. STEP 2 STEP 3 .a1.� RECCOr.tEhIDED FOP COIIDUIt ElJTPY it-30 F.00F >r , RAISED APEA II! MOLDED BASE' Remove any roofing nails beneath the 15t 2"d, or DRILL PILOT HOLE 3rd course of tile that obstructs the position of Slide RJ-1 Junction box into place where you the roof flashing. cut shingle template.The image above shows STEP 4 where you will drill in the next step STEP 5 www.soltection.com Soltection RJ-1 Installation Manual Page 8 ` d n{a N43 s V. mow. � r � ` L / + •1, � � r u�,r' t 'to w { 9 4° i i L?�"':�c• -?�y.�s..'+'h'^i'�{. to a� . ,. • 1 � 1 Remove RJ-1,flip it over,wipe it clean&apply Reinstall Unit. Use the two supplied Decking a bead of roofing sealant to the underside of the Screws to mount the flashing to the roof. flashing unit. Ensure that it's placed in the Torque to the specification indicated in the "Upside-down U"Shape to support engress specifications. Refer to Table T2(page 10)for water protection, AS SHOWN. the proper tightening torques. STEP 10 STEP 11 POPULATE RJ-1 �k, I7 • Populate the RJ-1 unit using the appropriate wire connectors, terminal blocks, or other necessary components. • Ensure that the components installed are rated for and are suitable for the intended purpose. • The RJ-1 unit is provided with multiple }� a standoffs which can accommodate accessories to be mounted. Step 11 . A Install the cover onto the top of the enclosure. Tighten 4 cover screws to the Torque value indicated in Table T3(see page 10) STEP 12 www.soltection.com Soltection RJ-1 Installation-Manual Page 10 7 p SPECIFICATIONS MECHANICAL/ ELECTRICAL ■ Product Certifications: UL508A ■ Enclosure Rating:Type 4X ■ Attic.Conduit Pass Through Connector Size Range: 1/2"—1" ■ Max.Side Wall-Conduit Size: 1" ■ Maximum Current: N/A ■ Maximum Voltage: N/A ■ Ambient Operating Temperature: -35C to 75C TORQUE RATINGS Table T1: Ground Bar Connection-Wire Range:#4 to#14,4 Usable Connections o - o 0 0 Wire Size Tightening Torque(lb- in) 4-6 AWG 35 8 AWG 30 10-14 AWG 25 Table T1 Table T2: Mounting Screw, Mounting to Decking, 2 Provided Tightening.Tor ue Ib4n -15-20- Table T3: Torque Values, Cover/Lid Screws , 4 Provided, Captive Ti htenin Tor ue (lb-in): 11 www.soltection.com Soltection RJ-1 Installation Manual Page 11 s S.01tection"' by vynckier Soltection is a division of Vynckier Enclosure'Systems, Inc. 271 McCarty Street Houston.,TX 77029 1-866-227-0577