Loading...
HomeMy WebLinkAbout21-1418 J City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001418-2021 t Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 02/01/2021 Permit Type: Electric Service Replacement/Misc Property Number Street Address 04 26 210070 00200 0120 36046 Stable Wilk Avenue Owner Information Permit Information Contractor Information Name: FRANCISCO&LYDIA COLON Permit Type:Electric Service Replacement/M Contractor:VIVINT SOLAR DEVELOPEF Class of Work:Add/Alter Residential LLC Address: 36046 Stable Wilk Ave Building Valuation:$4,147.00 ZEPHYRHILLS,FL 33541 Electrical Valuation:$16,588.00 Phone: (813)369-2598 Mechanical Valuation: Plumbing Valuation: Total Valuation:l$20,735.00 Total Fees:$275.52 (� Amount Paid:$275.52 r1 lJ Date Paid:2/1/2021 10:27:26AM Project Description INSTALLATION ROOF MOUNT SOLAR PV Application Fees Building Permit Fee '$60.74 Plan Review Fee $30.37 Electrical Plan Review Fee '$61.47 Electrical Permit Fee $122.94 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. 'Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording;your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRAC OR SIGNATURE PE IT OFFICE PERMIT EX IRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CAL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Permit No- ParcellDNoQ�•7� 1•�2?�'V�ZQ�tI�ZQ NOTICE OF COMMENCEMENT L fi Stated Florida County of Pasco M O THE UNDERSIGNED hereby gives nice that improvement will be made to certain real property,and in accordance with Chapter 713.Florida Statutes, ti!it L the following information is provided in this Notice of Commencement (a O 17,91 1. Description of Property:Pa I tiflaatkLNQ�. I t p �.. YI E Sheet Address: V O �/ 1 V .c—`� �e Q O -- W U T 1 Y rt W t•- 2. General Description of Improvement Installadon of a roof-mounted solar photovoltaic system cc 0. fY r-4 y eE 3 L IA-) E O 01 3. Owner Information or lessee information if the Lessee oonhaeted for the improvement 9 O m ! tJ Caw%c1. C010 ,a 16 is,ct® o a me57J�Iej f A P� fly L N > 7 Ad City State N g N Q V Interest in Property. N O Name of Fee Seriph Titleholder ia- lV .i (If different from Owner fisted above) Z , v -'Z N H m tY o ZLL Address city State 4. Contractor. Vivint Solar Developer,LLC Name 5100 W Hanna Ave Tama FL-1�34 Address City State Contractors Telephone No.: _ (818)359-MU i S. Surety: Name Address city State Amount of Bond:S Telephone No.: n. Lender. Name Address City Stall Lenders Telephone NO.: T. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(/),Florida Statutes: Name i Address City State Telephone Number Of Oeaignated Person: a. In addition to himself,the owner designates of_ to receive a copy of the Liencrs Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner, 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction final payment to the contractor,but will boons year from the dated recording unless a different date is specified): WARNING TO OWNER. ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY- A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING.CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that r have read the foregoing notice at commencement and that the facts stated therein are true to the best of my knowledge and befiet_ 00 /-- STATE OF FLORIDA COUNTY OF PASCO ftnallZa of Owner or Lessee,or Owners or Lessee's Authored OfficedolrectoLlpartnedManager � /�►t _ Signtat1ory'sTitlelOfficye.; [I� �'•.., �i-�/The foregoing instrument was acknowledged beforenis this0 kw n� day of 1 ai. 20a, t I a �_I sK_` cc/ 11 as (type of authority.e.g.•officer,trustee,attorney in fact)for (name Of party on hsh2lf at whom inmrf ni s execut/ed/)t. Personalty Known❑OR Produced rdentification Notary Sigriature Type of Identification Produced O Name(Print) —�v State Fltxifa GO 903833" gig@ wpdatafbcslnoticecammencement_pe0S30�16 Building Department Untie Racotifed _j 7T PhomeConiact for Pend 51.5 "i's / . Ownaft Name . . . .Owner 40Phone Number r1 2S Qwriads AddressslaBLE hLELM AJE. owner Phone Number Fee Simpille Titleholder Name F7- owner Phone Number Fee Simple TilleftolderAddress JOB ADDRESS 190M.0 509RLT JAIULI ii--ZrP1-19DJr6ATffi SUBOMSION E=,rP4 bd JP PARCEL 109 (OWAIKEDPROPERTYTAXWnCE) WORK PROPOSED NEW CONSTRR ADO/ALT SIGN r-1 OEMOUSH R INSTALL REPAIR PROPOSED USE 0 SFR p COMM OTHER I TYPE OF CONSTRUCTION p BLOCK p 'FRAME Q STEEL =] r— DESCRIPTION OF WORK 1rAJVM-1.1qrZQA1 BUILDING SIZE SO FOOTAGE "EIGHT . . . .. . . .. . . ... . . .. . . . . . . . . . . . . . . . . .. .... BUILDING 14 L/I VALUATION OF TOTAL CONSTRUCTION 16LECTRICAL $ * AMP SERVICE p PROGRESS ENERGY Q W.R.E.C. I Apa =pLumaING 1 3 =MECKWCAL VALUATION OF MECHANICAL INSTALLATION =GAS p ROOFING p SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOO ZONE AREA [ YES NO . . . . .. . . . . . . . . . . . . ... .. . . . . . . . . . . . . . . If BUILDER COMPANY r a VVAJ r Lne SIGNATURE REGISTERED YIN I FEECuRREN LILM 1 Fr-r - 'Address 9zo W.)41glyAtiq "4vr—1 j Lici '?00t1-7 .q ELECTRICIAN COMPANY QgLAR SIGNATURE REGISTERED YIN I FEJ1---CURPEi% L_jLN J F'�;�11'eo P License#FT-C/:Too(,-7 q Addmas P V 1:-� PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEECURREN Address License MECHANICAL COMPANY = SIGNATURE F REGISTERED I Y/ N FEECURREN Address I ucense#F— OTHER COMPANY = SIGNATURE REGISTERED I Y/N I FEECURREw LXLN 1 Addr.. License#F ttttttttttttettttttttttttttttttttttrttttttttttetttttttttttttttttttt RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for now cortzmuction. Minimum tan(10)working days altarsubmittal date. Required onsite.Construction Plans,Stomwrater Plans wl Silt Fence Installed, Sanitary Facifftles&I dumpster,Site Work Permit for subdivislonsilarge projects COMMERCIAL Attach(2)complete saw of Building Plans plus a Ufa Safety Page;(1)set of Energy Farms.R-O-W Permit for now constructicri. Minimum ten(10)working days after submittal date. Required onsits,Construction Plans,Stormwateir Plans wl Silt Fence installed, Sanitary Facilities&I dumpater.Site Work Permit for d now projects.AD commercial requirements must meet compliance SIGN PEWIT Attach(2)sets at Engineered Plans. PROPERTY SURVEY required forall NEW construction. Ol161611"it. . . . . . . . . . . . ...0 Fig out application completely. Owner&Contractor sign back of application,notarized If over Mae,a Notice of Commencement is required. (AlCuPgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroaft if shingles Sewers Service Upgrades A/C Fences(PlatfSurvey/Footage) Driveways-Not over Counter if an public madways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed'restrictions" which may be more restrictive than C6unty regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. I . f UNLICENSED CONTRACT014S AND CONTRACTOR RIESOONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance!with StetaL and local regulations. If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, If the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the'contractor Bloch'of this application for which they Will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not property licensed and is not entitled to permitting privileges In Pasco County. TRANSPORTATION IMPACTAITILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89417 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,Will be identified at the time of permitting. It Is further understood that Transportation Impact Fees and Resource Recovery Fees,must be paid prior to receiving a'certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or trial power release,the leas must be paid prior to;permit issuance. Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I car* that 1, the applicant have been provided�with a copy of the 'Florida Construction Lien Law—Homeowner's Protection Guider prepared by the Florida Department of Agriculture and Consumer Affairs. if the applicant Is someone other than the'owner",I certify that I have obtained a copy of the above described document and promise in good%M to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT. I cartify that all the Information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land developmenL Application is hereby made to obtain a permit to do work and installation as Indicated. I certify that no work or Installation has commenced prior to issuance of a permit and that all work Will be performed to meet standards of all law's regulating construction, County and City codes,zoning regulations, and land development regulations In the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the Intended work,and that it is my responsibility to identify what actions I must tak4 to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads,Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater TreatmenL - Southwest Florida Water Management District-Wells, Cypress Bayheads, Weiland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. I US Environmental Protection Agency Asbestos abatement Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill Is not allowed in Flood Zone'T unless expressly permitted. - If the fill material is to be used in Flood Zone 'A7, it is understood that a drainage plan addressing a "compensating volume Will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. i - If the fill material is to be used In Flood Zone"K in connection with a permitted building using stem wall construction,I certify that fill Will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill Will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by ill[,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing,signs,wells, pools,air conditioning,gas,'or other Installations not specifically Included in the application. A permit issued shall be construed to be a license to proceed With the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors In plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested,In writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER. YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE ON COMM ENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and swam to(or affirmed)before me this Subscribed and dWom-07(or afflrmedybsfcWm1"#S.— Who Were personally known to me or hasihave produced who ally� as Identification. �94� Notary Public _Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Docu-Sign Envelope ID:7FBB976C-F93F-4B2A-8632-2A5DFF93FCBB vw'nt solar° 18®® hShU� Blvd. A sunrun COMPANY. J.Matthew Walsh, PE Kirk M. Nelson, SE Samuel Brown, PE.Civil Director of Engineering Shuctural Engineering Structural Engineering james.walsh@sunrun.com kirknelson@sunrun.com sam.brown@sunrun.com December 18, 2020 i Re: Structural Engineering Services Colon Structure 36046 Stable Wilk Ave; Zephyrhilis, FL S-6532783; CAD Version: 5; FL-01 To Whom It May Concern: i We have reviewed the following information regarding solar panel installation on the roof of the above referenced structure: 1. Site visit by a representative .from our, office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. .Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels' and have the following comments related to our review. and evaluation: A:.Description of Structure: The existing structure has typical wood,framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Southern Pine#2 or better with-standard construction components. The designed areas of the home consist of the following framing methods: • Roof Section: Prefabricated trusses at 24" on center. Survey photos indicate that there was free access to verify the framing size and spacing. • Roof Section: Prefabricated trusses at 24" on center. Survey photos indicate that there was free access to verify the framing size and spacing. B. Loading Criteria 14.66 PSF= Dead Load (roofing/framing) 3.00 PSF= Dead Load (solar panels/mounting hardware) 17.66 PSF =Total Dead Load 20 PSF= Roof Live Load (based on local requirements) Wind speed of 145 mph (based on Exposure Category D-the total area subject to wind uplift is calculated for the Interior,-Edge, and Corner Zones of the dwelling.). C.Solar Panel,Anchorage 1.. Installation shall proceed.in accordance.with;the applicable guidelines and, recommendations indicated below. If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. • SnapNrack Installation Manual,which can be found on the SnapNrack website(https:Hsnapnrack.com). vivint.Solar° Page Iof2 Asunrun COMPANY DocuSign Envelope ID:7FBB976C-F93F-4B2A-8632-2A5DFF93FCBB i 2. The solar panels are 1'/" thick. Ati.no time will the panels be mounted higher than 10" above the existing surface of the roof. 3. The following mounting types shall be used. Please refer to the mounting details for the associated mounting method requirements. Based on our evaluation, the uplift demand.is less than the maximum allowable per mount and therefore is adequate: . • RL-U SpeedSeal: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) of timber construction specifications for Southern Pine is 235 Ibs/inch penetration. 4. Fasteners are installed.to meet industry standards and this document satisfies requirements in 2017 FBC 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above,.using the wind load uplift-procedures of ASCE 7-10: These spacing requirements apply to all mount types indicated above. The following values have been verified by in-house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections should be staggered, where possible, to distribute load to adjacent members. . Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner -Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 48 48 48 33 31 34 Cantilever in 16 16 16 11 10 11 D.Summary Based on the above evaluation,with appropriate panel anchors being utilized,the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida Building Code- Residential 6th.Edition, current ind__ustry standards and practice, and the information supplied to us . at the time of this report. ' If there are any questions regarding the above, or if more information is required, please contact me. \\\ �,�NE W y�, Regards, �\ Q. .9 i1, J. Matthew Walsh, PE • S FL License No. 84923 * N 84 } STATE OF DocySig'ned by: I % i((/� N Matthew Walsh z... /� s 111111.ONAI.,O?\\\� December 21,2020 1 5:47 PM MST 12/18/2020 This item has been electronically signed and sealed by Matt Walsh . . using a Digital Signature and date.Printed copies of this document are not considered signed and sealed and the;signature must be verified on any electronic copies. vivint.-Solare, Page 2of2 A:Sunrun COMPANY DocuSign Envelope ID:7FBB976C-F93F-4B2A-8632-2A5DFF93FCBB Structural Design Criteria _ Project Address Date: December 18,2020 Colon Residence 36046 Stable Wilk Ave Zephyrhills,FL S-6532783 \\\ '(14E VI/ Residence \� �Q'•�,\c E N SF•, �� i�� Risk Category II 1•, y Roof Area 1849 sf * No 84y' Upper Floor Area 1387 sf — Number of Stories 2 STATE OF Mean Roof height 25 ft 0", , Upper Floor height loft i�F, '�CORIOP'�,IN C9?`\ \�\ Location Parameters ��Ss10NAL Latitude 28.25134699 ��►mr��ae\� Longitude -82.22047525 Site Class D(Default) Risk Category II Existing Gravity Parameters Roof Dead Load Floor Dead Load 5 psf Composite Shingle 7.50 psf Floor Finishes 2 psf 3/4"Plywood Sheathing 3.30 psf 1 1/8" Subfloor Sheathing 2 psf Roof Framing @ 24 in;o.c. 3.40 psf Joists @ 16'o.c. 3 psf Ceiling,Mechanical,Electrical 15 psf Partitions 2 psf Miscellaneous 3.60 psf Ceiling,Mechanical,Electrical 15 psf TOTAL - 1.25 psf Miscellaneous 34 psf TOTAL Roof Live Load 20 psf Wall Dead Load Ground Snow Load 0 psf 8 ft Wall Height Flat Roof Snow Load 0 psf 300 ft Wall Length 12 psf Wall Weight New Gravity Parameters Roof Dead Load 3.00 psf Solar Panel Weight Roof Live Load with Solar Panels 0 psf Roof Slope Factor 0.8 Roof Slope Factor(ASCE 7-10 Fig.7-2b) Roof Snow Load 0 psf ASCE 7-10 Eq.7.4-1 Seismic Parameters SS = 0.067 g 0.2 sec Spectral Response Acceleration Sl = 0.034 g 1.0 sec Spectral Response Acceleration Fa= 1.600 g Site Coefficient from ASCE 7-10,Table 11.4-1 Fv= 2.400 Site Coefficient from ASCE 7-10,Table 11.4-2 SDS = 0.071 g Short Period Design Spectral Acceleration SD1 = 0.054 g 1 Second Period Design Spectral Acceleration Page 1 of 4 DocuSign Envelope ID:7FBB976C-F93F4B2A-8632-2A5DFF93FCBB Wind Parameters Wind Speed 145 mph Exposure Category D Roof Angle, 0 23.0 deg Product Information No.of Panels 29 Weight 3.00 psf including mounting system Installed Area 526.4 ft2 No.of Connectors 38 Total Existing Roof Load=Roof Dead Load+(Roof Live Load or Snow)x Spacing 69.32 plf Total New Roof Load=Roof Dead Load+Added Dead Load+(Roof Live Load or Snow)x Spacing) 35.32 plf Change in Demand=(Total New Load-Existing Load)/Existing Load 49.05% Total New Gravity Loads are less than Existing Loads. OK 2015 IEBC Section 707.2 states: "Where addition or replacement of roofing or replacement of equipment results in additional dead loads,structural components supporting such reroofing or equipment shall comply with the gravity load requirements of the International Building Code. EXCEPTION 1.Structural elements where the additional dead load from the roofing or equipment does not increase the force in the element by more than 5 percent." 2015 IRC Section AJ501.4 states: "The minimum design loads for the structure shall be the loads applicable at the time the building was constructed,provided that a dangerous condition is not created. Structural elements that are uncovered during the course of the alteration and that are found to be unsound or dangerous shall be made to comply with the applicable requirements of this code." 2017 FBC Section AJ104.1 states: "Detached one-or two-family dwellings that are not irregular buildings under Section R301.2.2.2.5 and are not undergoing an extensive reconstruction shall not be required to be evaluated." Page 2 of 4 DocuSign Envelope ID:7FBB976C-F93F-4B2A-8632-2A5DFF93FCBB }}� 1800.�?-Ashtoh Blvd.Lehi, UT 84043 StE'L1dural Grdup J /IRaftNeW Ulna/sty,PE Kirk_Nl.Nelson, SE Samuel Brown;,PE-:Cqv!!, .Director of En fneeii S�tucCurai .g n9 Er(pFneeruig : SruureP E+1girrrng. rames:walsh vivintsolar com kirkn-eison@vivintsolar.com sam.hrownsvivfnrsolarcorn Mount Spacing Calculation ASCE 7-10 Simplified Procedure for Components and Cladding NDS Section 12 ICC Code Cycle 2015 Wind speed (V) 145 mph Exposure Category D Roof Slope (0) 23.0 deg Effective Wind Area 20 sf Least Horizontal Dimension 30.00 ft Adjustment.Factor(A) 1.61 Topographic (Kt) 1 Panel Dead Load (Pd) 3 psf Ground Snow Load 0 psf Flat Roof Snow Load (pf) 0 psf ASCE 7-10 Eq. 7.3-1 Slope Factor(CS) 0.78 ASCE 7-10 Fig. 7-2b Panel Snow Load 0 psf Pfc. Total Dead Load (D) 3 psf Panel Dead Load + Roof Snow Load Portrait Landscape Vertical Spacing (L) 67 in 39''in Based on length of the panel Wind Pressure Zone 1 Zone 2 Zone 3 Lookup Pressure (Pnet30) 31 psf 49 psf 89 psf ASCE 7-10 Fig. 30.5-1 Uplift Pressure W 51 psf 79 psf 144 psf A*Kzt*Pnet.30 Fastener Type 5/16 Yield Equations NDS Table 12.3.1A Diameter 5/161 in I m 654 Ibs Fasteners 1 I s 1235lbs Embedment (Dpen) 2 1/2 in II 363 Ibs Load Duration (Cd) 1.6 III m 376 lbs. Pullout per Inch (W) 235 lb/in III s 393 Ibs IV 339 Ibs Uplift Capacity 939 Ibs DpenCdW Shear Capacity 339 Ibs Based on equations from NDS 12.3.1A Page 3 of 4 �,�1 it Docuftn Envelope,ID:7FBB976C-F93F-4B2A-8632-2A5DFF93FCBB li 180O.W A6hton Surd: Lela, LPT W43 :structural Group J. I aftlieKrWafs ;PF Kir3c.A I i9on, SE Samuel roa�irn;-PE'-.,Caaiil, �7irectn�bfEnArrreerir� - �tPuctur�J..Eragrnee�ing �rrErtgi,�eirrrg james-waJsh@vivinrso/ar co►r� kirkrretsan,@vivintsofar o.m sarn�cQural:browii vivinFsolar eom i Mount Types: Uplift Shear Fasteners . (Capacities based on manufacturer testing) RL-U.S eedSeal 4431bs 238Ibs 1 i Fastener Capacity 939 Ibs 3391lbs Controlling Capacity 443 Ibs 23811 lbs Portrait Zone 1 Zone 2 Zone 3 Uplift 33 in 31!in 34 in Shear 437 in 658 in 1316 in Capacity Manufacturer or AHJ 48 in 46 in 48 in L*SIN(9)*D Controlling Spacing 33 in 31 in I 34 in Landscape Zone 1 Zone.2 Zone 3 Capacity Uplift 57'in 54 in 58 in L*0.6(D-W) Shear 750 in 1127 in 2255 in Capacity Manufacturer or AHJ 48 in 481 in 48 in L*SIN(6)*D Controlling Spacing 48 in 48!in 48'in Tributary Area (Atrib) Zone 1' Zone 2 Zone 3 Mount.Spacing *Vertical Spacing Portrait 15 sf 1 G sf 5 sf Landscape 13 sf 9'sf 4 sf I Demand in Uplift Atdb*0.6(Pd-W) Portrait 443 Ibs 443 Ibs- 443 Ibs Landscape 372 lbs 39$ lbs 365 lbs Capacity, in Uplift 443 Ibs 443 Ibs 443 Ibs Max Utilization=1.00 Demand in Shear- AWb*SIN(6)*D Portrait 18 Ibs 11 ilbs 6 Ibs Landsca a 15 Ibs 10 Ibs 5 Ibs Capacity in Shear 238 Ibs 238 Ibs . 238 Ibs Max Utilization=0.08 Page 4 of 4vivin r s d nsol �. �s . ...... r � � • o.PERC o a c dule k m �"' 0N A``'B�pCK N'gn densl 320 W 340 133b,3351340�AS C51N,320132 POWER tion Warranty.on R,aterials ORE sore area, ct ize the light ab 16°� ,,5 enhanced p an h'p* Maxim to 2 i uP-ro efficiency.UP. and Workm - 2o.16°to module ears � Q'"A4amm+� B- coefficient(pi�'ax)' rantY�` how temperature over output War %/`C 4) $ linear p rranty statement. year' Solar uniited Wa ,��, Canadian shading tolerance to the applicable�a ...•............ «pccordin9 Sir Better YSTEM CERI,IFICA?E MANpGEM�Nt a)ity management OsteM en al management system' 0151 vironm ationa1 health&safety 150 g001:2 occup ISO 14001:2015/standards en. E RE1.Ip►g�E 20071 International standards for MOR ONSp518001: `oWer internal current, -a ficK'{ES* of temperature PROV)UCT V It, cE 1 MC5 u5)1 F5Ec(6S Florida) loW er hot sp IEC 61730:VDE 1, CEC listed region, IEC 612151 ante: small IEC 61215 perform 62716:VDE Cell crack risk limited r ul 1703/C5A 1 IEC 61701 ED2:VDE 1 IEC enhance the module reliability u►.17o3: •�"� CE tact Your Take a"Way lease con e ets•p to the to 5400 p a, f �r is indifferent ,faca es applicable OW load UP DVE Cous�lr on requiretnen spedfic c d Heavy sn 2400 pa ° t certirica`es ntatNe for tareta b . Wind load UP t0 a a tansthan sofa o in Wh1ci' roducts .........•to pro in high 5 to inthe reg. ......................m►tted vidna service Products.........................O R I{�C.is CO sol►1�tion5 a uality'. CANpp�N S solar system.module supplier for q. roducts, NO. rn . orner Insight quality solar.P World. Module Cuss ers around the do in IFIS d manufacturer custom anceipriPV protect developer an d the WO and perform deployed at SuNey As a leading over 3$GW Of solar modules since 2001 ENGINEERING DRAWING(mm) CS1 H-330MS/I-V CURVES Rear View Frame Cross Section A-A A A 1g0 1 12 r" 11 11 35 10 10 ❑ ill 9 9 8 s-la y 8 / m 7 7 ze /I ounl�Fting T 6 6 I ' 5 5 _______-__-_11 4 4 _____.Mounting Hole 3 3 z 2 -- ° v ° v 5"10 15 20 25 30 35 40 45 50 5 10 15 20 25 30 35 40 45 50 6-m5 Grounding H. 'II "-I-" .1000 W/w 5-C ■ A ",i JA S goo wrro 25°C ■ l' ® 600 W/M' 45°C 9 9 400 WW 65°C 2 200 W/W ELECTRICAL DATA I STC* 11AECHANICAL DATA CS1H 320MS 325MS 330MS 335MS 340MS Specification Data Nominal Max.Power(Pmax) 320 W 325 W 330 W 335 W 340 W Cell Type Mono-crystalline Opt.Operating Voltage(Vmp) 36.2 V 36.6 V 37.0 V 37.4 V 37.8 V Dimensions 1700 X992 x35 mm Opt.Operating Current(Imp) 8.85 A 8.88 A 8.92 A 8.96 A 9.00 A (66.9 x39.1 x 1.38 in) Open Circuit Voltage(Voc) 44.0 V 44.1 V 44.2 V 44.3 V 44.5 V Weight 19.2 kg(42.3 Ibs) Short Circuit Current(Isc) 9.41 A 9.45 A 9.49 A 9.53 A 9.57 A Front Cover 3.2 mm tempered glass Module Efficiency 18.98% 19.27% 19.57% 19.86% 20.16% Frame Anodized aluminium alloy Operating Temperature -40*C-+85°C J-Box IP68,3 bypass diodes Max.System Voltage 1000V(IEC/UL) Cable 4.0 mm2(IEC), 12 AWG(UL) TYPE 1 (UL 1703)or Cable Length 1350 mm(53.1 in) Module Fire Performance CLASS C(IEC 61730) (Including Connector) Max.Series Fuse Rating 15 A Connector T4 series or H4 UTX or MC4-EV02 Per Pallet 30 pieces Application Classification Class A Per Container(40'HQ) 780 pieces Power Tolerance . 0-+5 W *Under Standard Test Conditions(STC)of irradiance of 1000 W/mz,spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA I NMOT* TEMPERATURE CHARACTERISTICS CS1H 320MS 325MS 330MS 335MS 340MS Specification Data Nominal Max.Power(Pmax) 236 W 240 W 243 W 247 W •251 W Temperature Coefficient(Pmax) -0.37%/°C Opt.Operating Voltage(Vmp) 33.4 V 33.7 V 34.1 V 34.5 V 34.8 V Temperature Coefficient(Voc) -0.29%/°C Opt.Operating Current(Imp) 7.07 A 7.11 A 7.14 A 7.17 A 7.20 A Temperature Coefficient(Isc) 0.05%/*C Open Circuit Voltage(Voc) 41.0 V 41.1 V 41.2 V. 41.3 V 41.5 V Nominal Module Operating Temperature 44±3*C Short Circuit Current(Isc) 7.60 A 7.63 A 7.66 A 7.70 A 7.73 A *Under Nominal Module Operating Temperature(NMOT),irradiance of 800 W/m2 spectrum AM 1.5,ambient temperature 20°C,wind speed 1 m/s. PARTNER SECTION .......................................................................................................... The specifications and key features contained In this datasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement.Canadian Solar Inc.reserves the right to make necessary adjustment to the information described herein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. :...:......:............................................................................................... ................................................................................................................................................................................................................................................ . . . Sin le "Phase Inverter g wit h H D W- a.v:' ' e Te c h•no' I gy for North America 'SE3000WUS / SE3800H-US / SE5000H-US / SE6000H=US SE760OH-US /:SE1:000OH-US:/:SE11400H-US. YEAR :. T �— solar ••- solar-.. h.:. .. b ...1- i v o. Optimized installation with HD-Wave technology / Specifically designed to work with / Extremely small power optimizers / Record-breaking efficiency / Built-in module-level monitoring /. Fixed voltage inverter for longer strings / Outdoor and indoor.installation / Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data,ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) / UL1741 SA certified,for CPUC Rule_21 grid compliance solaredge.com' Solar • • / Single Pha$e Inverter with HD-Wave TechnOlOgy for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V S000 6000 @ 240Y 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000.@.208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min.-Nom.-Ma x. ✓ ✓ ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3 60-60.50) Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240v Maximum Continuous Output 16 24 48.5 A Current @208V GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 S900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 I 15500 — W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240Vj4 8.5 10.S 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V12l - 9 13.5 I 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kn Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V Nighttime Power Consumption <2.S W ADDITIONAL FEATURES Supported Communication Interfaces RS48S,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional"' Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG DC Input Conduit Size/ of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1°Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 In/ (HxWxD) mm Weight with Safety Switch 22110 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -13 to+140/-25 to+60(4)(-40°F/-400C option)'ll T/`C Protection Rating NEMA 4X(Inverter with Safety Switch) I11 For other regional settings please contact SolarEdge support 123 A higher current source may be used;the inverter will limit its input current to the values stated 01 Revenue grade inverter P/N:SExxxxH-1JS000NNC2 ldl For power de-rating information refer to:httpsV/wvAv.solaredge.com/sites/default/files/se-temperature-deraCng-note-na pdf rn-40 version P/N:SExxxxH-US000NNU4 m SolarEdge Technologies,Inc All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc All RO H S