Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
21-1434
'v ► !I�u��.; City of Zephyrhills PERMIT NUMBER !" , 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001434-2021 - Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 02/24/2021 � s Permit Type: Electric Service Replacement/Misc Property Number Street Address 05 26 21 0100 00700 0080 6964 Silverado Ranch Boulevard Owner Information Permit Information Contractor Information Name: DAN GREGORY ONEAL MARTHA Permit Type:Electric Service Replacement/M Contractor: TESLA ENERGY BEACH Class of Work:Add/Alter Residential OPERATIONS INC Address: 6964 Silverado Ranch Blvd Building Valuation:$0.00 ZEPHYRHILLS,FL 33541 Electrical Valuation:$26,800.00 Phone: (919)815-7549 Mechanical Valuation: Plumbing Valuation: Total Valuation:$26,800.00 �,2 Total Fees:$261.00 Amount Paid:$261.00 Date Paid:2/24/2021 10:07:32AM Project Description INSTALLATION ROOF MOUNT PHOTO VOLITIAC SYSTEM SOLAR Application Fees Electrical Permit Fee $174.00 Electrical Plan Review Fee $87.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER r 7 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received 2- -� Phone Contact for Permitting L=813 �460 7640 -rr�-ems-rr - - -rrrr Owner's Name ONEAL DAN GREGORY Owner Phone Number 919.815.7549 Owner's Address 6964 SILVERADO RANCH BOULEVARD Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6964 SILVERADO RANCH BOULEVARD, ZEPHYRHILLS 33541 LOT# SUBDIVISION PARCEL ID#1 05-26-21-0100-00700-0080 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED B NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE SFR F-1 COMM = OTHER I SOLAR TYPE OF CONSTRUCTION BLOCK FRAME = STEEL INSTALLATION OF ROOF MOUNTED PHOTO VOLTAIC SYSTEM AND (1) TESLA DESCRIPTION OF WORK BUILDING SIZE SQ FOOTAGE= HEIGHT =BUILDING $26,800.00 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY = W.R.E.C. =PLUMBING $ ✓� 1=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION CD C-!V =GAS = ROOFING = SPECIALTY = OTHER 5\ ✓c FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER �s� �({,/n ' COMPANY TESLA ENERGY OPERATIONS, INC. SIGNATURE L � REGISTERED Y/ N FEE CURREN Address 5012 JOANNE KEARNEY BLVD TAMPA, FL 3361 License# I EC13006226 ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# i l l l l l l l l l l l l l l l l l l l l l l t l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l 1.1 1 1 1 1 1 1 1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, — - Sanitary Facilities-&-1-dumpster,-Site Work"Permit for subdivisions/large-projects ---- COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms. R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""`*PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) •* Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 0 �1 W . oW SOLAR- PURCHASE DISCLOSURE This disclosure is designed to help you understand the key terms of your purchase of a solar electric system ("System"). It is not a substitute.for your purchase contract:("Contract"), loan or any other documents.associated with this transaction. Information.presented below is subject to the terms of your Contract. Read all documents carefully so you fully understand the transaction. For more information on becoming a smart solar consumer please visit www.seia.org/consumers. .Provider: Tesla,-Inc. Installer: Tesla Energy Operations, Inc. Customer: Greg Oneal Address: 3500 Deer Creek Road Address: 901 Page Avenue- System Installation Address: Palo Alto, CA 9.4304 Fremont, CA 94538 6964 Silverado Ranch Blvd, Tel.: 888-518-3752 Tel.: 888-765-2489 Zephyrhills, FL 33541 License#(if applicable): Not State/County Contractor License#: Customer Mailing Address: Applicable FL EC13006226/CCC1331559 6964 Silverado Ranch Blvd , Email: Email: Zephyrhills, FL 33541 energycustomersupport@tesla.com energycustomersupport@tesla.com Email: goneal@tesla.com I Contract Date: 1/27/2021 Purchase Price Your purchase price,, including the cost of the Powerwall(s): $26,800.00 List of any credits, incentives or rebates included in the above purchase price: $100.00 *NOTE: Not everyone is eligible for credits,,incentives or rebates or can fully use them. Consult your tax professional or legal professional for further information. Payment Schedule Amount you owe Provider at Contract signing: $0.00 Amount you owe Provider at the commencement of installation: $0,00 Amount you owe Provider at the completion of installation: $0.00 Your financing partner will make the final payment to the Provider after installation for the following amount: $26,800.00 Financing Your system: WILL be financed NOTE: If your System is financed, carefully read any agreements and/or disclosure forms provided by your lender. This statement does not contain the terms of your financing agreement. If you have any questions about your financing . arrangement, contact your finance provider and read.all financing disclosures before signing a Contract. Installation Timing Approximate Start Date: 7-90 days from the date the Agreement is signed. Approximate Completion Date: 7-90.days from the day installation begins. Interconnection Approval PROVIDER is responsible for submitting a System interconnection application. Site & Design Assumptions for your Purchase The estimated size of your System is: 8.16 kW DC Estimated gross annual electricity production in kilowatt-hours (kWh) from your System in Year 1: 10,769 kWh Solar Purchase Disclosure v.2021 4450525 NMI 0 Estimated System Lifetime: 30 years Estimated annual electricity, production decrease due to natural aging of the System: 0.5% System location on your property: rooftop Connectivity: The System WILL'be connected to the electric grid. At the time"of installation, your local utility WILL credit you for excess energy your System,generates. The rules applying to such credit are set by your jurisdiction. Your utility offers a net energy metering policy"as required under state statute or as regulated by a public utility commission. Changes in net energy metering policy or utility rate structures during the life of the system may result in lower utility bill savings than estimated or none at all; Tesla.Energy will not be responsible for reassessing the contract rate. Your 1 Powerwall system has an initial storage capacity of 13.50 kWh and contains an integrated storage inverter/charger capable of providing a combined 5.00 kW of continuous power and 7.00 kW of surge power. System Maintenance & Repairs System maintenance IS included for 20 years from the Installer. You are required to perform the following system maintenance: • Shade Management: Shading on your solar display dramatically reduces electricity production. Keep trees or other tall plants trimmed to prevent shade on your system. • Panel Cleaning: Cleaning your panels"of debris can improve your system performance. Flushing the panels from the ground with a water hose can let more sunlight'penetrate through the glass cover. "System repairs" refers to actions needed to fix your System,if it is malfunctioning. System repairs ARE provided by..the Installer. If System repairs ARE included, the coverage periods for each hardware component of your System (in years) are: Solar Panels: at least 12 years Inverter Warranty: at least 10 years , Powerwall Warranty: 10 years Please check the Manufacturer's warranty for the coverage period of other hardware components. If System repairs ARE included, the coverage periods for the labor/workmanship for each component,of your System (in years) are: Solar System: 20 years .Powerwall System:4 years Please review your Contract for additional information about any warranties on the System installation and equipment. Note that equipment warranties for hardware are not required to include labor/workmanship. Your Provider may assign or subcontract any of its rights or obligations under this Agreement to any affiliate, successor, partner or purchaser. If such a transfer occurs,you will be notified if this will change the address or phone number to use for system maintenance or repair requests. Roof Warranty Your roof IS warranted against leaks from the system,installation for the first 10 years by the Provider. Performance or Production Guarantee Provider is not providing you with a performance or production guarantee. Taxes You are responsible for property taxes on property you own. Consult a tax professional to understand any tax liability that may result from entering the Contract. Utility and Electricity Usage/Savings Assumptions You HAVE NOT been provided with a savings estimate based on your purchase. Solar Purchase Disclosure v.2021 4450525 - / r t [oil M If provided, the savings estimate was calculated based on: System size. The savings estimate to you assumes the following: Your system will last: 30 years It is important to understand that electricity rates are estimates only. Your actual current and future utility rates and utility rate increases may vary.. Provider IS NOT guaranteeing these savings. Cooling Off Period/Right to Cancel In addition to any rights you have under state or local law, you HAVE the right to terminate this agreement without penalty within three (3) business days or within five (5) business days (CA Customers only) of 1/27/2021 8:47:47 PM +00:00 by notifying Provider in writing at the above address. SEIA Solar Business Code Provider DOES abide by and agrees to be bound by SEIA's Solar Business Code and its complaint resolution process. For more information about the SEIA Solar Business Code and complaint resolution process, please visit http://www.seia.org/consumers Additional Disclosures or Terms Powerwall System The Powerwall will draw 100% of its charge from the Solar Array. In backup mode, the Powerwall will provide automatic backup power to the circuits to which it is connected. In self-powered mode, the Powerwall will capture excess solar energy during the day to power your,Home at'night. Final determination of eligible circuits will be made prior to installation. Eligible circuits must be located in the same'electrical panel used to connect the Solar Array at the time we install.If we cannot install a Powerwall so as-to provide backup energy to at least eight (8) circuits that you request due to access or electrical constraints, you may cancel the Powerwall, and either opt to have a solar-only system installed, or cancel this Agreement entirely. Customer's Initials hereG O Solar Purchase Disclosure v.2021 4450525 • 0 0• : • 1 t Tesla Energy Products Purchase& Home Improvement Agreement This "Agreement" is between you and the Tesla entity ("Tesla", "we" "us" or "our') identified-below. It consists of (1) the below Price Sheet and (2) the attached terms & conditions, and is effective on the date you agree to this Agreement (by electronic acceptance, signature"or e-mail) and shall supersede all prior existing agreements between you and Tesla for the Testa Energy Products described below. Price Sheet !"Your information ..Greg Oneal 6964 Silverado Ranch Blvd Zephyrhills, FL 33541 9198157549 Tesla entity/Provider " Tesla, Inc. of 3500 Deer Creek Road, Palo Alto, CA, 94304 888-765-2489 Installer" Tesla Energy Operations, Inc. of 901 Page Avenue, Fremont, CA 94538 ' FL EC13006226/CCC1331559 Salesperson Name and License Number Laura Sherman, Energy Products and Contract Price Solar System $16,400.00 8.16 kW DC Solar Panels $4,592.00 Inverter(s) &.Balance of System $2,132.00 Mounting Hardware $984.00 Installation, Permitting, and Other Fees $8,692.00, Powerwall $10,600.00 1 Powerwall(s) $7,000.00 1 x Backup Gateway(s) $1,000.00 Powerwall Installation $3,500.00 Powerwall +Solar Discount ($1,000.00) r - • System Price $26,900.00 Taxes $0.00 Contract Price, $26,900.00 Credit for Order Payment '-($100.00) Energy Products Purchase&"Home Improvement Agreement V9.0, 1/1/2021 Testa, Inc. 4450525 1 Credit for Rebate Value ($0.00) Amount Due $26,800.00 Customer's Initials: G O Schedule of Payments Paid at Order, $100.00 Due When Installation Begins $0.00 Loan Amount $26,800.00 The schedule of progress payments must specifically describe each phase of work, including the type and amount of work or services scheduled to be supplied in each phase, along with the amount of each proposed progress payment. IT IS AGAINST THE LAW FOR A CONTRACTOR TO COLLECT PAYMENT FOR WORK NOT YET COMPLETED, OR FOR MATERIALS NOT YET DELIVERED. HOWEVER, A CONTRACTOR MAY REQUIRE A DOWNPAYMENT. The pricing in this Agreement is valid for 30 days after 1127/2021. If you don't sign this Agreement and return it to us on or prior to 30 days after 1/27/2021, Tesla reserves the right to reject this Agreement unless you agree to our then current pricing. You,the buyer,may cancel this transaction at anytime prior to midnight of the third business day or fifth business days after the date of this transaction.See the attached notice of cancellation form for an explanation of this right. Customer's Initials: G O If you are financing your System through one of our financing partners, the timing and amount of your payments (and any applicable interest accrued) will be subject to the terms and conditions of your agreement with your financier. If your financier fails to make payment on your behalf, or your financing is terminated by you or your financier, you will remain obligated to make payment under the terms of this Agreement. Estimated First Year Production (not guaranteed) 10,769 kWh Approximate Installation Start Date 7-90 days from the date of this Agreement Approximate Completion Date 7-90 days from the date of this Agreement Signed by Your signature Testa,Inc. Greg Oneal Name: Greg Oneal Date: 1/27/2021 8:47:47 PM +00:00 Name:RJ Johnson Title:Senior Director,Energy You are entitled to a completely filled in copy of this Agreement, signed by both you and Tesla, before any work may be started. Energy Products Purchase&Home Improvement Agreement V9.0. 1/1/2021 Testa, Inc. 4450525 2 INSTR#2021 012SIO3 OR BK 10262 PG 136 Pagel of 1 01/21/2021 10:02 AM Rcpt 2251252 Rec: 10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles, Esq., Pasco County Clerk&Comptroller Pem9t No. Parcel ID No 05.26-21-0100-00700-0080 NOTICE OF COMMENCEMENT state of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713.Florida Statutes, ' the following information is provided in this Notice of Commencement: 1. Description of Property. Parcel Identification No.05-26-21-0100007000080 SILVERADO RANCH SUBDIVISION PHASES 7 eB 11A AND I I B PB 77 PG 079 BLOCK 7 LOT Street Address: 6964 SILVERADO RANCH BOULEVARD,ZEPHYRHILLS,FL 33541 2. General Description of Improvement Installation of roof-mounted photo-voltaic system and'fesla Powerwall(s) 3 Owner Information or Lessee information it the Lessee contracted for the improvement: - DAN GREGORY O'NEAL Name 6964 SILVERADO RANCH BOULEVARD _ ZEPHYRHILLS FL Address City Slate Interest in Property: HOMEOWNER Name of Fee Simple Titleholder: N/A WA (If different from Owner listed above) N/A NIA Address City Stale 4. Contractor Tesla Energy Operations,Inc. Name 5012 Joanne Kearney Blvd Tampa FL Address City State Contractor's Telephone No: 813.460.7640 5, Surety. Name WA WA N/A Address City Stale Amount of Bond $NIA Telephone No: MA 6 Lender. WA Name NA NIA NIA Address CIry State Lender's Telephone No.. NIA T. Persons within the State of Florida designated by the owner upon wham notices or other documents may be served as provided by Section 71313(1)(a)(7),Florida Statutes NIA Name N/A N/A NIA Address City State Telephone Number of Designated Person: NIA 8. In addition to himself.the owner designates NIA of N/A to receive a copy of the Lances Notice as provided in 6eclion 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner NIA 9 Expiration date of Notice of Commencement(the expiration date may not be before the completion of construcWn and final payment to the contractor,but will be one year from the date of recording unless a different date is specified) • WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,1 declare that 1 have read the foregoing notice I commenncceemee�nntt and thatthe facts stated therein are true to the best ' of my knowledge and belie(, STATE OF FLORIDA COUNTY OF PASCO Sig 1ptioid of'OViner or Lassie,or Owitens Or Lessees AU1horiTed OfRcol0t aclor/Pa i lnerlManagor Homeowner Signatory's Title/Office The foregoing utslrument was acknowledged before me this l6a y of�.�i�locy�120ji,by_ if AS Owner ,�tJ (type of authority,e.g.,officer,trustee,attorney in fact)for Owner Meet of oa-rty on behalf of w. 15trument was it cvlur!). Personally Known[I OR Produced Idenld+calwn❑ Notary Signature �' '4"(l�t_1 t Type of Identification Produced iiJ`I`I V.tllr �•f(-.l�InS P.. Name(Print) CYNTHW MARIE GARAFOL'O 4�f ''MY C0117MIS310N#GG14S8�0 EXPIRES SOPllWrrl�er 24,20V wpdata/bcs/no licecomm encement_pcO53048 NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain.as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide' prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone_ other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby. made to obtain a permit to do work and installation as indicated. I certify-that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. -If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under.the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work.ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING-TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN F!hKNCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTIC60F CaIMEMEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affir ed)before me this by o 2S Ojai by AI MLAe, AU66T fLp kkn Who is/are personally known to me or has/have produced WHO is/a a personally known to me or has/have produced as identification. 00. OL # 5CI410IRG as identification. Notary Public 1 I Notary Public Commission No. Commission o. 14 01 k1 7 Name of Notary typed,printed or stamped Name of Notary typed, k, SYDNEY WILLIAMS Notary Public-State of Florida • `o; Commission a HH 081157 y ovvtF My Comm.Expires Jan 14.2025 Banded through National Notary Assn. REVISION 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received 4/22/21 813.460.7640 Phone Contact for Permitting — err I = ' Owner's Name DAN ONEAL Owner Phone Number 919.815.7549 Owner's Address 6964 SILVERADO RANCH BLVD,ZEPHYRHILLS,FL 33541 Owner Phone Number Fee Simple Titleholder Name I I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6964 SILVERADO RANCH BLVD, ZEPHYRHILLS 33541 LOT# SUBDIVISION PARCEL ID# 05-26-21-0100-00700-0080 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT = SIGN = DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM = OTHER I sown TYPE OF CONSTRUCTION BLOCK FRAME = STEEL DESCRIPTION OF WORK REVISION - REMOVE LOAD CENTER AND LOADS MOVED TO MAIN SERVICE PANEL BUILDING SIZE SQ FOOTAGE= HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION J. =GAS ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER F - COMPANY TESLA ENERGY OPERATIONS, INC. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 5012 JOANNE KEARNEY BLVD.TAMPA,FL 33619 License# EC 13006226 ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N J FEE CURREN Y/N Address License# OTHER - COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# tllllllllltlllllllllllllllllllllllllllllllllllllll11111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2).sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after.submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, _Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. ■ t t-- t 1 1 1 - - A ■ Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) " Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW _j NOTICE.OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the.owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies.include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety '(90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FIN NCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICEC E EMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Zoe I Subscribed and sworn to(or affirmed)before me this Su crib d and sworn o(or a d)before me this by 2 I /ZO Who is/are personally known to me or has/have produced M6 is/ar personally known .me or has/have produced as identification. as identification. Notary Public Z42�t ,e Notary Public Commission No. Commission No. GG a 3 a 8 6P Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Notary Public State of Florida Loraine R Mullins my Commission GG 232486 Expires 05126/2022 T L Limited Power of Attorney Date:04/06/2021 RE:PERMIT AUTHORIZATION Lorraine Mullins Dear Sir or Madam: Colin Winslow Chantel Sharp This letter is to verify that Andrew Argudo is an authorized representative of Tesla Energy Operations and is authorized to pull any and all permits, business licenses, and other project related documents as needed. Please don't hesitate to call me if you have any questions. Sincerely Nich s Armstrong Responsible Managing Employee, License#EC13006226 Regional Vice President ALL-PURPOSE CERTIFICATE OF ACKNOWLEDGEMENT A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document,to which this certificate is attached, and not the truthfulness, accuracy or validity of that document. State of North Carolina County of Mecklenburg On April 6,2021 before me, Nicholas Armstrong personally appeared,who proved to me on the basis of satisfactory evidence to be the person who name is subscribed to the within instrument and acknowledged to me that he executed the same in his authorized capacity, and that by his signature on the instrument the person,or entity upon behalf of which the person acted, executed the instrument. I certify under penalty of perjury under the law of the State of Florida that the foregoing paragraph is t a c r ct O�PF1 Signature o otary •`r0TAR=Y2a1'- �' •• PUBLIC v: �� I%� ••.QBERA"' •��: T=SLn Fla. Admin. Code R. 61G15ER20-10 Section 61 G15ER20-10-Printed Copies of Digitally or Electronically Signed and Sealed Plans Considered Valid During the effective period of this rule,comprising ninety(90)days from the effective date, the restriction contained in Rules 61 G l 5-23.004(3)(c)3. and 61 G 15-23.005(4)(c)3., F.A.C., that printed copies of digitally or electronically signed and sealed plans or documents is removed,and printed copies of said plans or documents are deemed validly signed and sealed for any purpose allowed by law. After the expiration of this emergency rule,the restriction is re-imposed. Any licensee seeking to use printed copies of digitally or electronically signed and sealed plans or documents must retain an original copy of the signed and sealed plans. Flu.Admin.Code Ann.R.61G15ER20-10 RulemakingAulhoritr:471.008,471.025,471.033(2),FS.Lair Implemented:471.025,471.033(l)(n), (e),6), 668.003,668.006, FS. Adopted by Florida Register Volume 46,Number 141,July 21,2020 effective 7-17-20. w casetext i 1 Notice of Emergency Rule DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION Board of Professional Engineers RULE NO.: RULE TITLE: 61G15ER20-4: Printed Copies of Digitally or Electronically Signed and Sealed Plans Considered Valid SPECIFIC REASONS FOR FINDING AN IMMEDIATE DANGER TO THE PUBLIC HEALTH, SAFETY OR WELFARE: The Florida Board of Professional Engineers("FBPE") is statutorily mandated to require the forms by which plans or other documents are considered properly signed and sealed by a Florida Professional Engineer. Pursuant to this authority, the FBPE has promulgated rules in Chapter 61G15-23, Florida Administrative Code. These rules allow three forms of signing and sealing: digital, electronic, or physical. The current rules specifically mandate that printed copies of digitally or electronically signed and sealed plans are not considered signed and sealed. However, a number of building departments, authorities having jurisdiction, or other state, county, or local governmental agencies do not currently accept digital or electronic plans or documents, requiring physically signed and sealed documents be submitted or filed. On March 1,2020, Florida Governor Ron DeSantis issued Executive Order Number 20-51 which directed the State Health Officer and Surgeon General, Dr. Scott Rivkees, to declare a public health emergency in response to the spread of the Novel Coronavirus Disease 2019 (COVID-19). On March 9, 2020, Governor DeSantis issued Executive Order Number 20-52 (Emergency Management - COVID-19 Public Health Emergency) and officially declared that a state of emergency exists in the State of Florida. On April 1, 2020, Governor DeSantis issued Executive Order Number 20-91 (Essential Services and Activities During COVID-19 Emergency), which directed all persons within the State to remain at home unless engaged in the provision of essential services or engaged in essential activities. COVID-19 is a severe acute respiratory illness that can spread among humans through respiratory transmission and presents with symptoms similar to those of influenza. As of April 8,2020,there are over 14,000 confirmed cases of COVID-19 in the State of Florida. The Center for Disease Control ("CDC") recommends mitigation measures to combat the spread of COVID-19 such as staying home when sick, keeping away from others who are sick, staying home when a household member is sick with respiratory disease symptoms, and for those who are at higher risk, including older adults and those who have serious chronic medical conditions, to avoid non-essential travel, interpersonal contact,and to avoid groups of persons as much as possible. Since the issuance of the Executive Orders and declaration of a public health emergency by the State Health Officer and Surgeon General Dr. Rivkees, the FBPE office has received a number of calls and emails from licensees who are concerned about having to interact in person to physically sign and seal plans and documents in order to have those documents filed. All have suggested that removing the requirement that printed copies of digitally signed and sealed copies are not considered signed and sealed; they suggest this would allow the plans to be digitally or electronically signed and sealed,and then those documents could be transmitted by electronic means,and printed by the recipient,which would eliminate the need for groups of licensees to meet, or individual licensees to leave their homes to travel to a location to sign/seal the plans and then physically deliver them. It has been strongly suggested this will satisfy the purpose and intent of the signing and sealing law without exposure to the dangers of being in groups of people, necessity of travel itself, potential contribution to the spread of the virus, and most importantly, would ensure compliance with the State Health Officer's Orders,CDC Recommendations,and Governor DeSantis's Emergency Orders. Florida's Professional Engineers, and those who come in contact with them,should not be unnecessarily put at risk during this healthcare emergency. Accordingly,the FBPE, by emergency rule, will waive the restriction that printed copies of digitally or electronically signed and sealed plans or documents are not considered signed and sealed as required by Chapter 471, Florida Statutes, and Rule Chapter 61G15-23, Florida Administrative Code. The FBPE finds that this action is a measured regulatory approach that helps to mitigate the threat of exposure to COVID-19 to Floridians, including Professional Engineers and those that come in contact with them, while still satisfying the purpose and intent of the waived restriction. REASON FOR CONCLUDING THAT THE PROCEDURE IS FAIR UNDER THE CIRCUMSTANCES: Given the recently declared emergency in the State of Florida;Emergency Order 20-91;the recent guidance from the CDC; and the fact that professional engineers will be required to maintain the original digitally or electronically signed and sealed documents, the FBPE finds that an immediate danger to the public health, safety, or welfare necessitates immediate action regarding this issue.Notice of this meeting was published in the Florida Administrative Register in Volume 46,No. 71,on April 10,2020. 1n addition,notice of the FBPE's meeting was posted on the FBPE's official website. SUMMARY: The proposed emergency rule removes the restriction that printed copies of digitally or electronically signed and sealed plans or documents are not considered signed and sealed,thus allowing printed copies to be used in any manner in which physically signed and embossed sealed plans could otherwise be. Removal of the restriction would only be for the ninety-day effective period of the emergency rule. THE PERSON TO BE CONTACTED REGARDING THE EMERGENCY RULE IS: Zana Raybon, Executive Director, Board of Professional Engineers, 2639 North Monroe Street, Suite B-112, Tallahassee, FL 32303; (850)521-0500,ZRaybon@fbpe.org. THE FULL TEXT OF THE EMERGENCY RULE IS: 61G15ER20-4 Printed Conies of Digitally or Electronically Signed and Sealed Plans Considered Valid. During the effective period of this rule,comprising ninety(90)days from the effective date,the restriction contained in Rules 61G15-23.004(3)(c)3. and 61G15-23.005(4)(c)3., F.A.C., that printed copies of digitally or electronically signed and sealed plans or documents is removed, and printed copies of said plans or documents are deemed validly signed and sealed for any purpose allowed by law. After the expiration of this emergency rule, the restriction is re- imposed. Any licensee seeking to use printed copies of digitally or electronically signed and sealed plans or documents must retain an original copy of the signed and sealed plans. Rulemakine Authority: 471.008,471.025,471.033(2), FS. Law Implemented:471.025,471.033(1)(a). (e). (i).668.003,668.006 FS.Historv—New 4-15-26. THIS RULE TAKES EFFECT UPON BEING FILED WITH THE DEPARTMENT OF STATE UNLESS A - LATER TIME AND DATE IS SPECIFIED IN THE RULE. T E� S Ln March 26, 2019 Testa Powerwall Hardware Compliance Letter To whom it may concern: ` The installation manual for the Tesla Powerwall was reviewed for mounting considerations. Based on the weight of the unit and the attachment layout of the mounting bracket, it was determined that the following fasteners should be used: Wood Studs: (4) -%"wood screws with w/2-1/2" minimum embedment Metal Studs: (3)-'/4" sheet metal screws at each corner w/ 1-1/2" minimum penetration (25 ga stud minimum) (1)—'/4' sheet metal screws at each corner w/ 1-1/2" minimum penetration (18 ga stud and thicker) Concrete/CMU: Schedule "A"for clear height less than 2'-9" FASTENER SCHEDULE "A"+ MANUF MODEL DIAMETER EMBEDMENT SIMPSON TITEN Y"6 HILT] KWIK—CONN H + Y"v 1 " POWERS TAPPER + Ya"o Schedule "B"for clear height greater than 2'-9" and/or if the governing jurisdiction requires fastener ESR report*. FASTENER SCHEDULE "B"* MAvUF MODEL DIAMETER EMBEDMENT ESR SIMPSON TITEN HD 3�"0 2-" ESR-2713 (CONCRETE) & ESR-1056 (CMU) HILT] KH—EZ Wo 1%" ESR-3027 (CONCRETE) & ESR-3056 (CMU) POWERS .WEDGEBOLT + Wo 1Y2" ESR-2526 (CONCRETE) & ESR-1678 (CMU) E R` •sr ICH AS R O GORIDON -n Exp: m 0 CIVIL p a -a 410. 22W' TESLA MOTORS, INC 3500 Deer Creek Rd, Palo Aliu. CA. 0,1304 p 650.681.5000 f 650.681.5200 C , August 04, 2020 Re: Tesla Retrofit PV Structure Qualification Certification Letter Tesla's Retrofit PV.product is an assembly consisting of Tesla mounting hardware for comp shingle or tile roof coverings and PV modules using the Zep Compatible frame. Please refer to the product data sheets, UL listing, and installation documentation for further information. The Tesla Retrofit PV assembly does not exceed 3.5psf. Installation of the Tesla Retrofit PV assembly offsets load in areas of the roof designed to support a roof live load and provides a lower-friction surface than the existing roof. The weight of the offset live load or difference in accumulated roof snow load as a result of reduced surface friction (in regions where the roof snow load is greater than the roof live load) will exceed the weight of the PV assembly. Consequently, the net additional loading impact to existing gravity load resisting elements is less than 5% for the framing of pitched roof structures with existing roofing material comprised of comp shingle or tile. Note that this assessment does not apply to structures with existing metal roof coverings in regions where roof snow load is greater than roof live load. I certify that installation of the Tesla Retrofit PV assembly on existing structures with: a) existing roofing material comprised of comp shingle or tile roof coverings and b) with no existing structural damage; meets the criteria outlined in Section 403 of the IEBC (alterations to existing structures) and is therefore permitted by code without alterations or strengthening of the existing framing. �`��% As �O %�' ...•��ii��, �`♦G • 1GENS Q �� Digitally signed by Nick � •• v ••2 Nick Gordon'Gorcion * No.81915 * C Date:2020.08.0412:20:08 b = -07100' �� , •� Q E i •••� THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED By LAS GORDON N THE DATE SHOWN USING A ,,�,� •• �,,�Q``,,,, DIGITAL O O L SIGNATURE.PRINTED COPIES OF THIS DOCUMENT III tits ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Nick Gordon, P.E. Associate Manager, Professional Engineering, Tesla_ ngordon(a)-tesla.com Licenses: AZ, CO, CT, FL, MA, MD, MI, NH, NV, NY, OR, PA, RI, SC, TX &VT T S S L Fi Tesla,Inc. 3500 Deer Creek, Palo Alto.CA 9130n ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG 1 THIS SYSTEM IS GRID-INTERTIED VIA A UL-LISTED BUILDING CONC CONCRETE DC DIRECT CURRENT POWER-CONDITIONING INVERTER. EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. A NATIONALLY - RECOGNIZED TESTING EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN FIRE SET-BACK GALV GALVANIZED GEC GROUNDING 'COMPLIANCE WITH ART. 110.3. ELECTRODE CONDUCTOR GND GROUND HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING DIPPED GALVANIZED I CURRENT Imp CURRENT AT I MEANS MAY BE ENERGIZED IN THE OPEN POSITION, MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17. BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PROPERTY LINE P01 POINT OF INTERCONNECTION PHASE AND SYSTEM PER ART. 210.5. PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY STEEL STC STANDARD TESTING CONDITIONS TYP WITH ART. 250.97, 250.92(B). TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE OR ARE RUN IN METALLIC RACEWAYS OR AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ENCLOSURES TO THE FIRST ACCESSIBLE DC CD�l�ji� DISCONNECTING MEANS PER ART. 690.31(E). Nq 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 8. MODULE GROUNDED AT THE UL - LISTED LOCATION PROVIDED MANUFACTURER USING UL LISTED GROUNDING HARDWARE. /N 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE S' BONDED WITH EQUIPMENT GROUND CONDUCTORS. �•'���.O,C� �� VICINITY MAP NDEX Sheet 1 COVER SHEET Sheet 2 SITE PLAN Sheet 3 STRUCTURAL VIEWS Sheet 4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES Sheet 5 THREE LINE DIAGRAM Sheet 8 CUSTOMER PLAN - PORTRAIT 1. ALL WORK SHALL COMPLY WITH THE 2017 Cutsheets Attached FLORIDA BUILDING CODE (6TH EDITION), FLORIDA FIRE PREVENTION CODE (6TH EDITION). 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Zephyrhills City REV BY DATE COMMENTS REV A NAME DATE COMMENTS * * UTILITY: Duke Energy (FL) L * J B-3 35899 00 CUSTOMER: UE P�FT D DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: , CONTAINED SHALL NOT BE USED FOR THE Greg 0 Neal 8.16 KW PV ARRAY Alonso Ortiz T 5 L R BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 6964 Silverado Ranch Blvd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTSORGANIZA MODULES: Zephyrhills, FL 33541 THE SALE ON, EXCEPT IN CONNECTION �m AND USE OF THE RESPECTIVE (24) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: PERMISSION OF TESLA INC. INVERTER: SolarEd e Technologies Ltd. _SE760OH-US 240V COVER SHEET 1 12/15/2020 PITCH: 23 ARRAY PITCH:23 MP1 AZIMUTH:78 ARRAY AZIMUTH: 78 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 23 ARRAY PITCH:23 MP2 AZIMUTH: 168 ARRAY AZIMUTH: 168 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 20 ARRAY PITCH:20 MP3 AZIMUTH: 258 ARRAY AZIMUTH: 258 I MATERIAL: Comp Shingle STORY: 2 Stories RELAY Ins ASS OO D LEGEND (E) UTILITY METER & WARNING LABEL C INVERTER W/ INTEGRATED DC DISCO a SV m� & WARNING LABELS (E) DRIVEWAY p o IR AUTOMATIC RELAY ZT19 DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS 2 DC JUNCTION/COMBINER BOX & LABELS V ENERGY STORAGE SYSTEM FOR STAND a ESS ALONE OPERATION DISTRIBUTION PANEL & LABELS LG LOAD CENTER & WARNING LABELS DEDICATED PV SYSTEM METER tch Front Of House i2 RSD RAPID SHUTDOWN 3p 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR SV CONDUIT RUN ON INTERIOR GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED i "1 INTERIOR EQUIPMENT IS DASHED L /1 SITE PLAN N Scale: 1/8" = 1' IN E 0 1' 8' 16' S CON J 8-33589 9 00 CUSTOMER: DESCRIPTION: DESIGN: FlDENIIAL- THE INFORMATION HEREIN JOB NUMBER: � CONTAINED EEFIT SHALL NOT BE USED FOR THE Greg O'Neal 8.16 KW PV ARRAY Alonso Ortiz T 5 L n BENEFlT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 6964 Silverado Ranch Blvd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS Zephyrhills,rh ill s, FL 33541 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: p y THE SALE AND USE OF THE RESPECTIVE (24) Hanwho Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE: PERMISSION OF TESLA INC. SolarEdge Technologies ies Ltd. SE76OOH-US [240V1 SITE PLAN 2 12/15/2020 Si (N) PV MODULE (E) MOUNTING PLANE (MP) SV TYPICAL PV SIDE VIEW NTS PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER INSTALLATION ORDER ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT____________ J HOLE. --------- --- -------- ZEP MOUNTING BLOCK (4) FATTACH FLASHING INSERT TO AND ATTACH ZEP FLASHING INSERT (3) AFTERBUS ULOCKSING LAG SCREW. (E) COMP. SHINGLE (1) 22"MIN. INJECT SEALANT INTO FLASHING (E) ROOF DECKING (2) �(3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE ROOF PENETRATION. 5/16" DIA STAINLESS LOWEST MODULE SUBSEQUENT MODULES STEEL LAG SCREW rINSTALL LEVELING FOOT ON TOP [4) OF MOUNTING BLOCK & (E) RAFTER SECURELY FASTEN WITH BOLT. S1 STANDOFF Scale: 1 1/2" = 1' J B-3 35899 O O CUSTOMER: DESCRIPTION: DESIGN: CONFlDENTIAL- THE INFORMATION HEREIN JOB NUMBER Greg O'NealCONTAINED SHALL NOT BE USED FOR THE 8.16 KW PV ARRAY Alonso Ortiz T 5 L R BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: � PARTSHALL IT BE TO OTHERS I OUTSIDE THE HLE OR IN ZS Comp V4 w Flashing—Insert 6964 Silverado Ranch Blvd 13.5 KWH ENERGY STORAGE SYSTEM ORGANIZATION. EXCEPT IN CONNECTION WITH MODULES: Zephyrhills, FL 33541 THE SALE AND USE OF THE RESPECTIVE (24) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE PERMISSION OF TESLA INC. SolarEdge Technologies Ltd. SE760OH-US [24Ov1 STRUCTURAL VIEWS 3 12/15/2020 Jobslte Specific Design Criteria Design Code ASCE_7_10 Importance Factor I 1 Ultimate Wind Speed V—Ult 140 Fig.1609A Exposure Category C Section 26.7 Ground Snow Load pg 0 Table 7-1 MP Specific Design Information MP Name MP1 MP2 MP3 Roofing Comp Shingle Comp Shingle Comp Shingle Standoff ZS Comp V4 w ZS Comp V4 w ZS Comp V4 w Flashing—Insert Flashing—Insert Flashing—Insert Pitch 23 23 20 SL/RLL PV 0.0 psf 0.0 psf 0.0 psf SL/RLL Non—PV 19.0 psf 19.0 psf 19.5 psf Standoff Spacing and Layout MP Name MPI MP2 MP3 Landscape X—Spacing 72' 72' 72' Landscape 24' 24' 24' X-Cantilever Landscape Y—Spacing 41' 41' 41' Landscape _ — — 1—Cantilever Portrait X—Spacing 48' 48' 48' Portrait X—Cantiever 16' 16' 16' Portrait Y—Spacing 69' 69' 69' Portrait Y—Cantiever — — — Loyout Staggered Staggered Staggered X and Y are maximums that ore always relative to the structure framing that supports the PV.X is across rafters and Y is along rafters. CON J B-3 3589 9 00 CUSTOMER: DESCRIPTION: DESIGN: FlDENTIAL- THE INFORMATION HEREIN JOB NUMBER: , CONTAINED SHALL NOT USED FOR THE Greg O'Neal 8.16 KW PV ARRAY Alonso Ortiz T 5 L R BENEFIT EFlT O OF ANYONE EXCEPT PT TESLA INC., NOR MOUNTING SYSTEM: � SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 6964 Silverado Ranch Blvd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES Zephyrhills, FL 33541 ORGANIZATION, EXCEPT IN CONNECTION W ITH THE SALE AND USE OF THE RESPECTIVE (24) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DAIS PERMISSION OF TESLA INC. SolarEd a Technologies Ltd. # SE760OH-US [24OVJ UPLIFT CALCULATIONS 4 12/15/2020 GROUND SPECS MAIN PANEL SPECS I GENERAL NOTES LICENSE BOND (N) #6 GEC TO (N) GROUND ROD Panel Number: NoMatch CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:3465709 I I C-10 Underground Service Entrance E 200A MAIN SERVICE PANEL E5 200A/2P MAIN CIRCUIT BREAKER (N) 125A SQUARE D LOAD CENTER 04 AUTOMATIC RELAY 01 200A 2P RELOCATED LOADS 100A/2P 7OA/2P 40A/2P• TO • jjfEXISTING SOLAR — G ----- --------- --- N G r-- � a I (N) 1ODA 2P 3 I I I TOA/2F 00 L1 FEED THROUGH LUGS i �•RELOC i I L21 ENERGY N , •LOADS ' N I STORAGE --- EGC/GEC - (N) 200A INTERNAL I L_-_-__- _ EGC_ SYSTEM z ; LOAD CENTER 02 EGC N 12 L1 TO 120/240V I hr i SINGLE PHASE z UTILITY SERVICE I (N) 100A 2P r . • • (E) LOADS (E) 200A LOAD CENTER Voc* = MAX VOC AT MIN TEMP POI (1)SQUARE D N HQM23D —(1)Groygd Rod V (1)SQUARE D q HO►A2100 /t, X (1)1092170—OS—J Breaker; A/2P, 2 Spaces 5/8 x 8, Copper Breaker, 1DOA/2P, 2 Spaces /-� TESLA AC POWERWALL 2.0; Home Energy Storage,13.5KWH, Stackable, 5.8kVA Z (1)Tesla #1232100-00—E I Y (1)SQUARE D A HQM230 Back—up Gateway 2.0 NA for AC PW 2.0 Breaker; DA/2P, 2 Spaces —(1)Eaton # BW2100 —(1)SQUARE D 8 HQM24D 100A Main Circuit Breaker, 2—Pole, 240V, 1OkAIC Breaker; 4t)A/2P, 2 Spaces —(1)Tesla 11529623-00—C —(1)SQUARE D #HOM1224L125PRB Pane oard Accessory Kit for OW 2.0 NA; 200A. 6sp/12cir, 120/240V, 1Ph Load Center;125A,Convertible,NEMA3R,12sp/24Cir,120v/240v,1OkAIC,Surface —(1)CUTLER—HAMMER N BR2100 —(1)CUTLER—HAMMER #BR240 —(1)SQUARE D N HQM270 Breaker; 100A/2 , 2 Spaces Breaker, 40A/2P, 2 Spaces Breaker; 7UA/2P, 2 Spaces —(1)CUTLER—HAMfA R #BQC230230 Breaker 30A 2P-30A 2P, 2 Spaces, Quojd lex __ (1)AWG #3, THWN-2, Red —(1)AWG #4, THWN-2, Black (1)AWGBlack (1)AWG #3, THWN-2, Black ®R[ —(1)Conduit ®L_L(1)AWG#10, THWN-2, Red (1)AWG #3, THWN-2, White NEUTRAL (1)AWG#4, THWN-2, White NEUTRAL Kit; 1" EMT (1)AWG#10, THWN-2, White NEUTRAL —(1)AWG #8, THWN-2, Green EGC —(i)AWG.#8,.THWN,2, Green . .EGC. —(1)AWG#10, THWN-2, Green EGC —(1)Conduit Kit; 3/4" EMT (1)AWG#3, THWN-2, Red Il'(1)AWG #3, THWN-2, Black ���� (1)AWG#3, THWN-2, White NEUTRAL —(1)Conduit Kit; 1" EMT (1)AWG #3. THWN-2, Red —(1)AWG #8, THWN-2, Green EGC ® (1)AWG #3. THWN-2, Black - IIL (1)AWG#3. THWN-2, White NEUTRAL —(1)Conduit Kit; 1" EMT —'1:•AWG k= THWN Green EGC CONFIDENTIAL— J B-33589 9 00 CUSTOMER: DESCRIPTION: DESIGN: THE INFORMATION HEREIN JOB NUMBER: � CONTAINED SHALL NOT BE USED FOR THE Greg O'Neal 8.16 KW PV ARRAY Alonso Ortiz T 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 6964 Silverado Ranch Blvd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS EXCEPT IN WITH MODULES Zephyrhills,rhills, FL 33541 THE SALE AND USE OF THE RESPECTIVE (24) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 p y TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE INVERTER: PERMISSION OF TESLA INC. SolarEdge Technologies Ltd. # SE760OH-US 240V THREE LINE DIAGRAM 5 12/15/2020 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS r LICENSE Inv 1: DC Ungrounded INV 1 — (1) SolarEdge Technologies Ltd. #SE7600H—US 240V i— (24) Hanwha 0—CELLS#Q.Peak DUO BLK—G6+ 340 Inverter, 7600W, 240/208V, 997; SetApp HD Wave w/ZB,AFCI PV Module; 34OW, 318.1 PTC, 40MM, Black Fr, MC4, ZEP, 1000V INV 2 Voc: 40.66 Vpmax: 33.94 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER Inverter 1 > 3, SolarEdge Technologies Ltd. DC. SE7600H-US [240V] DC- MP1: 1x12 _ EGC—————————————————TO MAIN PANEL J r AND ENERGY DcSTORAGE SYSTEM E DC+ . - - -------------------------- --- LT_ Da c hI 'MP2,MP3: 1x12 GND __ EGC- - ----------------------------------- G (1)Conduit Kit; 3/4" EMT CONDUIT MATERIAL TYPE AND SIZE TO BE DETERMINED IN THE FIELD TO NEC 2014 STANDARDS CONDUIT MATERIAL TYPE AND SIZE TO BE DETERMINED IN THE FIELD TO NEC 2014 STANDARDS Voc* = MAX V0C AT MIN TEMP AC P V (24)SOLAREDGE P400-5NM4MZM DC PowerBox Optimizer;400W, ZEP lI1O (1)AWG#B, THWN-2, Black (2)AWG #10, PV Wire, 600V, Black Voc* =480 VDC Isc =15--ADC (1)AWG#8, THWN-2, Red (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC (1)Con #t0,Kit; 3/4' EM-2, Green EGC Vmp =400 VDC Imp=10.07 ADC (1)Conduit .3/4" EMT -(1 AWG THWN-2, Green EGC — 1 Conduit Kit; 3 4 EMT * 5 . . . . .. . . . / . . (2)AWG #10, Wire, 600V, Black Voc =480 VDC Isc=15 ADC (1)AWG#10, THHN/THWN-2, Green EGC Vmp =400 VDC Imp=10.07 ADC (1)Conduit Kit; 3/4" EMT J B-3 3 5 8 9 9 CUSTOMER: DESCRIPTION: DESIGN: CONFlDENTIAL - THE INFORMATION HEREIN JOB NUMBER: , CONTAINED SHALL NOT BE USED FOR THE Greg 0 Neal 8.16 KW PV ARRAY Alonso Ortiz T 5 L R BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 6964 Silverado Ranch Blvd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS Zephyrhills,rhIIIS, FL 33541 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES p y THE SALE AND USE OF THE RESPECTIVE (24) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT. WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. SolarEdge Technologies Ltd. SE7600H-US [240V1 THREE LINE DIAGRAM 5 12/15/2020 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 6964 Silverado Ranch Blvd UTILITY SERVICE r S INVERTER AND DC DISCONNECT , s ENERGY STORAGE SYSTEM --------------------------I SOLAR PHOTOVOLTAIC ARRAY(S) --------------------- - PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-335899-00 CUSTOMER: DESCRIPTION: DESIGN: CONFiDENTiAL ED SHALL NOT FRE MSTIONED HEREIN R REITH JOB NUMBER: JB-335899 00 Greg O'Neal BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: 8.16 KW PV ARRAY Alonso Ortiz T 5 L R SHALL IT BE DISCLOSED IN MOLE OR IN ZS Comp V4 w Flashing—Insert 6964 Silverado Ranch Blvd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS Ze h rh ills, FL 33541 ORGANIZATION. EXCEPT IN CONNECTION WITH MODULES p y THE SALE AND USE OF THE RESPECTIVE (24) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE PERMISSION OF TESLA INC. SolarEd a Technologies Ltd. SE760OH—US 24OV SITE PLAN PLACARD 6 12/15/2020 • sol a r =@@ sol ar - e e SolarEdge Power Optimizer - Zep CompatibleTM Module Add-On For North America P400-ZEP ---— 1111— --- --- SolarEdge l a r E d g e PowerOptimizer I_I_______ _-____—; P300 ZEP(for 60teI1 PV modules)_, P400-ZEP(for 72&96-cell modules) _-_ INPUT TM RatedInert.DC power 300 400 W Zep Compatible Module Add-On Absolul•.x,1,3aimurnMAOVct1'tag[+VrLAEla:t�. 48 80 rrrrll .ur . For North America P300-ZEP, P400-ZEP • MPPTGuerattrr Rarize. 8-48 $1811 Vdc Maximiir- hnri+,Ir I Ir;., eI,1.^ 10.1 Adc •F..'.I I . .. -:1 12.63 Adc Maximum Efficiency 99.5 • Weighted Efficiency 98.8 Overvoltage Category I' OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) - __ _ _-- __ -------------1111----- I•�1- I'',ru•:.rutt.-+t L'J' r--. t5 Adc 'utl;lr tic ,0 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) - Safety Output Voltage per Power Optimizer _ Vdc STANDARD COMPLIANCE • EMC FCC PartiS Class B,IEC61000-6-2,IEC61000-6-3 Safety IE{621[19 1 i4rass I s-rfptyr LIES 741 ROHS Yes INSTALLATION SPECIFICATIONS YMaximum Allowed System Voltage 1000 Vdc unn'r.'.Ir.r.t Inc!uLIr 8 r,tuuiInrigg I.ra%.LEI ;V' r,al-tl 128 x 196 x 27.5/5 x 7.71 x 1.08 128 x 196 x 35/5 x 7.71 x 1.37 mm r In 128x152x35/ Dimensions excluding mounting bracket (WxLxH) 128 x 152 x 27.5/5 x 5.97 x 1.08 5 x 5.97 x 1.37 n/in lAre811f(including cables a..c lnounttng to ar Intl 721) 1 6 840/99 kg:/lb ' P'1(c:r.ne'tc• MCI Compatible 0ut;'ut Connector Double Insulated;MC4 Compatible Output Wire Length ;a=_,i i 0 1.2/3.9 n, ft Operating Temperature Range -40-+85/ aC--18t F Protection Rating IP68/NEMA 6P 0-wi' nr r'h r,(,h..! N.i.:¢.or.,r'tr.-5'-,•— t,-ie'mr. a,luwae .. PV SYSTEM DESIGN USING A SINGLE PHASE SINGLE PHASE THREE PHASE THREE PHASE SOLAREDGE INVERTER121 HD-WAVE 208V 480V Minimu 8 10 —T 18 Compatible with Zep Groove framed modules Maximum String Length(Power Opfimizeis) 25 7 Maximum Power per String SE7600H-US) 6000 1:'fit W Parallel Strings of Different Lengths or Yes Orientations Or;z ac et Up tc: n cre er,erp - ro a Fy:hr,hte or eff;clency;9• - 1 - f a •--- .ue bM 1 www.solaredge.us 0 1 I r .r,- POWER L TYPICAL SYSTEM LAYOUTS n 'rgy sto-age 7- ( 4 Ur.- ^:O•"@ O' buc ng. Its :ae v _ I H - H c, I•�•:�I Backup Gateway Utility �tp! r PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS At•%t I+.,r1. Njr'ili,M, :7i"IIr!,:.:•'.• Grid Frequency rTo is+ny nDtlpn5 I. Powerwall •rra:= is s i,P Ii•f•ir riry 75Z -r 1i7 mm ;.I i•.K.r-' r•1.,, .r.n+•r l.r:;x (29.6 in) ,?dl-ewer.cLaF. C. all ul.0 r:er L) rrlr ,-3, r,,r li,;,(„I T _ a L n P1 w5.,fl ,", 'pr( a.rt C.4r'C..- Maximum Output Fault Current 1-50 m" -. (45.5 ni) Imbalance for Split-Phase Loads p 9wgr F.'[!or nhrpul Rana,. - Power Factor Range(Full-rated v.r•: +Internal Battery DC Voltage Warranty ENVIRONMENTAL SPECIFICATIONS !j F-1 Operating Temperature - S�L I . Backup Gateway Maly't.;il ,I .1111 h• :'c= Grid Recommended Temperature Operating Humidity(RH) ... COMPLIANCE INFORMATION Storage Conditions Ln: Grid Connection Maximum Elevation Emissions Powerwall 6 I• o-ic.r ,rc k 6„'-„'. Enclosure Type Seismic Ingress Rating F!, Wet Location Rating ... Noise . Sin le Phase inverter with HD-Wave Technology for North America Single Phase I nverter Z SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ • < SE7600H-US / SE10000H-US / SE11400H-US Wit h HD-Wave Technology m APPLICABLE TO INVERTERS I' PART NUMBER SFXXXXH-XXXXXBXX. for North America OUTPUT SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / Rated AC PowerOutut ( 240V 2sV rz 20SV V SE7600H-US / SE10000H-US / SE11400H-US },. P ç24 ' C !Z'00 20 v z, VA �.C OutO t`✓_Laga t�1 Ncm. Mzx ✓ ✓ ✓ ✓ ✓ ✓ ✓ -- AC Ourr,it V l: e t.1!n-Nori.-Maz - ✓ - ✓ - - AC Fre�uenc/(Nomirab - Hz Q Q Qur'ert'a24rV 15 _ ,_ _a Maximum Cc•' 1 _ � _ r4 _ - 48.5 4 r rl I:I ` F_' ar !M— ,95 Q GFDI TPesP,old o ® Unlit\Moni;o I I - P'otctien,C. •�IJ� Y_s INPUT solar�y[.[ .�- .,,, $ solar; L' ..4im� � r.1•:• [7D Paver dIL40V iR00 ON Maximum DC Power 203V - - - 0 - - 15500 Al 4 Q -I.-.- Marimuri P�put Vr,ItaUE Vdc Nominal DC Iopal Vol;aoe 4 dc I n 5 10.5 - - - - 2p 27 Adc Maximum I' 9 Ax Q 4 ,. . - 45 Ax Reve'se-Polar' 1'cs Gicund-Fault Ii.latior Deteubc ... Maximum Ltverter Efftcie^cy 99 240V Optimized installation with HD-Wave technology I Specifically designed to work with I UL1741 SA certified, for CPUC Rule 21 grid compliance power optimizers / Record-breaking efficiency I Extremely small / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp i i I gultn module level monitoring I Fixed voltage inverter for longer strings I Outdoor and indoor installation I Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article I Optional: Revenue grade data, ANSI C12.20 690.11 and 690.12 Class 0.5 (0.5%accuracy) solaredge.com so I a r = f / Sincile Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE1000OH-US / SE1 140OH-US ADDITIONAL FEATURES =: RS»E'5, Cellular(optic Revw•.ue Grade Data,ANSI G 1220 Optional In„error Col-�nossioning wit!',te r_-t N lr •..:•'c:r,.: - _ Rapp Shutdown-NEC 2014 a-,u Autolnetl[Rapid Shutdo 2017 590.12wn STANDARD COMPLIANCE LIL'741 SA,•if 'P C SG 2 Carad.an AFCI t, Ana to TI L 1-07 Grid Connection Standaras 1 IEEE1547,Rile 21,Rule 1-' H11 Emissions FCC '=Class B INSTALLATION SPECIFICATIONS AC Output Condodt Size/AWG 14-0 AWG ?./4' Range I DC Input Conduct Srce/tr of Stgs/ AWG Par:re -.1ris/"4 5 A4VG �i " I' i AWG iDimensions with Safety Switco , x 070x 174 : ?r -=x 7 /540 z 070 x 185 n HxWx D) V.r I .. Sa*et,4... . =2 t/1035 Noise OBA i--I Natural !7:-. :LrT,pe rsure R,nue __ F 'C • Raul g NEMA 4X(Inverter with Safety Svnt_hi Rev?nun grade n/erm-F-N.SEr.xxxH-JSW0Bf-_4 Ft;ll power to at Izas SIrC/f22'F.la eue e!:o.•. _ . . to -f5 I!p:}I,1,, IES'y•f=.1'.= ' Y'ID'-7• aauf SolarEdge Technologes,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo.OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All Ro H S other tradem m arks entioned herein are trademarks or Ihe,r respective owners.Date:1//019N01/ENG NAM Subject to change without notice. POWER . • I - ovr _ u. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS C Il.c9c ^ce- _ar: 7u•-.t-s•r- :rf-'1—rl• tyro-- :.r. - r.3 F't.0 rerL} M... r C options .. .. .I•'n i Short Circuit Carr _+ h:u•r--c oil r'rv.',=. e -r:�,.. [.itsgx••� !: h•r_tr .S•v C ^rent . f Y o 5 L R =ser I11 Criers �.•.-•;=i•=-Vfle- 660 0 nog. )';t. Optional Internal PC rlLj•,aro Warranty r- r.•t — 149 COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS i t.1 :: Cr'1�ret, y Fc:•1QI•'brn Operating Humidity 17p, Emissions Maximum Elevation E,:virnr,•rs&rnl Enclosure Type Ct; _ MECHANICAL SPECIFICATION D UC1 -• 68.5 x 40.6 x 1,57in(includingframe) ;174px1030x4Cmm) B°6 — 47.41bs(21.Skg) —�--=- 0.13ini32m^s)hermallyore-stressed glass - 6.a... M,.cr6. - '•ros uea mm; — — with anti-reilecticn technology ° wr°p.r.,n Tm' Q'a•y� ra Composite film Black arod'lzed aluminum � InIm .6s uc3cm,; 6 x 20 mcnocrystalline Q.AA T UN solar half cells Junction 2.09-3.98 x 1.26-2.36 n059-0 71 io(53 l01 x 32-60 e 15-18 mm), °. Protection class IP67 with byoass diodes Cable 4mm'Solar cable;(+)≥43.31n(11C0 mm),(—),43,31n in(1100 mm) •pp°ms;DEinr_n; 136mm0mm[ Connecto Stash MC4;IP68 - r rI6r1<c,m, DETA,.4 z;ummt IJ63(trmn; T- t'3sm am . • ELECTRICAL CHARACTERISTICS • POWER CLASS 330 335 340 345 • A --�.,•:'•,v.+•At try't' • P , ]Wt 330 335 340 345 QCELLS Isc Al 10. 1 5047 10.52 10.58 � • 6 QGpMPq l -. - T V: ]Vi 40.15 43.41 4066 40.92 • 1,,,. [Al 9.91 9.97 1002 10.07 raaA ra _• — — V.,,. IV] 3329 — — u3623394342 34.25 • • ?r:•IJ•n.i.^.�e t) [%] ≥18.4 ±18.7 ≥19.0 o19.3 e+�AC .$p 2019 QCELLS ..;f F ..'NORMAL _• — — — — — — — — 0MPA ,r t,rt.; P , IW 2470 2507 254.5 258.2 3 •.• ' t — — — — Y —4 [AI 8.39 8.43 8.48 8.52 ?a:-•. -� „r„gr V-- VI 37.86 36.10 38.34 38.59 Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY . '--__ Iv,. A] 7.80 7.84 7.89 7.93 nHigher yield per surface area,lower BOS costs,higher _ _ v�== :V — — 31.66 _ 3197 32,27 —3257 power classes,and an efficiency rate of up to 19.5%. Measurement tolerances P,, -3%:Irz,V-,--5%at S-C 1000W/m`,25x2°C,AM 1.5 acccroino to 1=C 60904-3•'800W/m',NMCT,spectr.mAM:.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE INNOVATIVE ALL-WEATHER TECHNOLOGY Al least 95%o'nominal power during /11c); Optimal yields,whatever the weather with ':.., first year thereafter max 0.54% C_J excellent low-light and temperature behavior. degradation pe'year At least 93.1% .w of nominal power up to 10 years.At . �is~ -` - least 85%o'nominal power up to 7 ENDURING HIGH PERFORMANCE 25 years ro. Long-term yield security with Anti LID and Anti PID Technology'. All data within measurement tcleranc- ` Hot-Spot Protect and Traceable Quality Tra.QTM. 3 es Fun warranties in accordance with . :o° .ao 600 60o moo the warranty terms or the Q CEL-S sales organization of your respective ZEP COMPATIBLETM FRAME DESIGN ° e country. - ,.-•` •- Typical module performanceurrder rc,s tr00W/m'cendrtions in High-tech black Zep Compatible M frame,for improved aesthetics, comparisonto SIC conditions(25°c.lDoow/m') easy installation and increased safety. TEMPERATURE COEFFICIENTS a %/K; —0.04 C_• f [%/K] -a27 A RELIABLE usive25-year product y [%/K; -0.36 Iodine Operating Temperature NMOT [°F] 109±5.4(43±3°C) ���7 Inclusive product warranty and 25-year - - l linear performance warranty'. PROPERTIES FOR SYSTEM DESIGN .. - [V] 7000(IEC)/1000tUL) II O STATE OF THE ART MODULE TECHNOLOGY [A DC] 2C C(IEC)/TYPE 2(UL) r Q.ANTUM DUO combines cutting edge cell separation [lbs/ft 50(2400Pa)/53(2400Pa] 4e°=up to+185'F and innovative wiring with Q.ANTUM Technology. (-4o°C unto+85°C) Max.Test Load.Pushi Put;(UL}- [lbs/ft'] 75(3600 Pa)/7_F(3600 Pa) API test conditons according to IEC/'S 62804-12015.method B(-1510 V.168h) 'See Installation Manual See data sheet on rear for further information QUALIFICATIONS AND CERTIFICATES UL 17C3,CE-compliant,IEC 61215:2016.IEC 61730,2016. —_ Application Class II.i.S.Patent No 9,893,215(solar cells) THE IDEAL SOLUTION FOR: pug E CUS rooftop arrays on — — m comerc and industrial buildings Note:Installation instructions must be followed.See:he installation and operating manual or contact our technical service department for further information on approved installation and use of this product. GICELLS 400 SpeOC CenterIJose.Suite Engineered in Germany 400 Spectrum Center Jnve.Sui-e 1400,trnine,CA 92618.USA 1TEL+1 949 74859961 EMAIL Inq J•ryCaus q-cells.coml WEB www q-cells us r50IdfClty ®pSolar Next-Level PV Mounting Technology $0IdfClty ®pSolar Next-Level PV Mounting Technology Components ZS Comp for composition shingle roofs Mounting Block Array Skirt Interlock • Part No.850-1633 Part No.850-1608 or 500-0113 Part No.850-1388 or 850-1613 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 Flashing Insert Grip Ground Zep V2 Part No.850-1628 Part No.850-1606 or 850-1421 Part No.850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 �OMPAT� �� °�� Description PV mounting solution for composition shingle roofs Works with all Zep Compatible Modules coMPl"I Auto bonding UL-listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Captured Washer Lag End Cap DC Wire Clip LISTED Part No.850-1631-001 Part No. Part No,850-1509 Specifications 850-1631-002 (L)850-1586 or 850-1460 Listed to UL 1565 850-1631-003 (R)850-1588 or 850-1467 • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" 1 • Zep wire management products listed to UL 1565 for wire positioning devices Leveling Foot Part No.850-1397 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1839-001 Rev 0 Date last exported: April 29,2016 11:22 AM Document#800-1839-001 Rev 0 Date last exported:April 29,2016 11:22 AM PITCH: 23 ARRAY PITCH:23 MP1 AZIMUTH:78 ARRAY AZIMUTH: 78 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 23 ARRAY PITCH:23 MP2 AZIMUTH:168 ARRAY AZIMUTH: 168 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 20 ARRAY PITCH:20 MP3 AZIMUTH:258 ARRAY AZIMUTH:258 RELAY Inv ESS _. MATERIAL:Comp Shingle STORY: 2 Stories oQ O j ----\ - _ //\ LEGEND c!? (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO (E) DRIVEWAY a SV m� & WARNING LABELS O R© AUTOMATIC RELAY ztl9 u�xa DC DISCONNECT & WARNING LABELS � AC AC DISCONNECT & WARNING LABELS 2 DC JUNCTION/COMBINER BOX & LABELS V s O ENERGY STORAGE SYSTEM FOR STAND ALONE OPERATION DISTRIBUTION PANEL & LABELS ® Lc LOAD CENTER & WARNING LABELS ® ODEDICATED PV SYSTEM METER tch lz � RSD RAPID SHUTDOWN Front Of House 0STANDOFF LOCATIONS CONDUIT RUN ONEXTERIOR SV CONDUIT RUN ON INTERIOR GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED ' 'I INTERIOR EQUIPMENT IS DASHED L-'J SITE PLAN N Scale: 1/8" = 1' w E 01' 8' 16' S CONFIDENTIAL J 8-335899 00 CUSTOMER: DESCPoPTION: DESGN: - THE INFORMATION HEREIN JOB NUMBER: Alonso OrtIZ CONTAINED SHALL NOT BE USED FOR THE Greg O'Neal 8.16 KW PV ARRAY T 5 L R BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 6964 Silverado Ranch Blvd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES Zephyrhills,rhlllS, FL 33541 ORGANIZATION, EXCEPT IN CONNECTION WITH P Y THE SALE AND USE OF THE RESPECTIVE (24) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 PAGE NAME SHEET: REV: DATE TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF TESLA INC. SolarEd e Technologies Ltd. SE760OH-US 1240V1 SITE PLAN 2 12/15/2020 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES LICENSE BOND (N) AWG #6 TO (N) GROUND ROD Panel Number: AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: Underground Service Entrance �E 200A MAIN SERVICE PANEL E5 200A/2P MAIN CIRCUIT BREAKER TESLA (N) 200A INTERNAL 7 BACKUP GATEWAY 200A 2P Z RELOCATED L0� 00�2P 70�2P 40 ,2P • TO NEW • SOLAR F--I A — G — e , I _ L1 L J i i 6 L2 y ENERGY SuBFEED I I N STORAGE EGC SYSTEM THROUGH LUGS N I i L-_____ _ EGC - J z z EGC' N L2 L1 -- 'GEC I TO 120/240V i SINGLE PHASE UTILITY SERVICE I 100A 2P - - • • (E) LOADS XXA/2P (E) 200A DISTRIBUT10N PANEL POI-(1)Gr rld Rod �I 1)AWG #3, THWN-2, Black 5/8 n 8, Copper ®L-L(1)AWG #3, THWN-2, Red H Z (1)Tea # 1232100-0D-E II��LL(1 1)AWG#3, THWN-2, White Back-up Gateway 2.0 NA for AC PW 2.0 -(1)AWG #8, THWN-2, Green -(1)Conduit Kit 1 EMT, -(1)Eaton ;Y BW2100 1)AWG#10, THWN-2, Black 100A Main Circuit Breaker, 2-Pole, 240V, 1OkAIC O (1)AWG #10, THWN-2, Red 30A2P, 2 Spaces AWG -(1)CUTLER-HAMMER #BR230 1 10, 1HWN-2 White Breaker, ( ) # -(1)CUTLER-HAMM R #BR240 -(1)AWG #10, THWN.2, Green -(1)Conduit Kit; 3/4' EMT Breaker, 40A/2P, 2 Spaces (1)AWG #4, THWN-2, Black Breaker -(1)CUTLER-HAMMER f BR270 2 Spaces (1)AWG #4, THWN-2, Red 70A/2P. -(1)Panelboard Accessory Kit for GW 2.0 NA tOOL.(1)AWG #4, THWN-2, White -(1)AWG #8, THWN-2, Green 200A, 6sp/12cir, 120/240V, 1PH y (1)1092170-05-J (1)AWG #3, THWN-2, Black TESLA AC POWERWALL 2.0; Home Energy Storage,13.5KWH, Stackable, 5.BkVA O (1)AWG #3, THWN-2, Red L�L(1)AWG #3, THWN-2, White (1)AN , THWN-2, Green —(1)Conduit Kit 1' EMT CON J B-3 3 5899 00 CUSTOMER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: ' Alonso Ortiz CONTAINED SHALL NOT BE USED FOR THE Greg O Neal 8.16 KW PV ARRAYT 5 L R BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: L IT BE DIS L OUTSIDE THE LECI'AIIOLE IN ZS Comp V4 w Flashing—Insert 6964 Silverado Ranch Blvd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS ORGANIZATION. EXCEPT IN CONNECTION WITH MODULES: I Zephyrhills, FL 33541 THE SALE AND USE OF THE RESPECTIVE (24) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 PAGE NAME SHEET: REV: DAIS TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF TESLA INC. SolarEdce Technologies Ltd. SE7600H-US [240V] THREE LINE DIAGRAM 5 12/15/2020