Loading...
HomeMy WebLinkAbout21-1456 ID v I Inn City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BNR-001456-2021 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 02/15/2021 Permit Type: Building New (Residential) Property Number Street Address 24 26 21 0110 00000 2370 39752 Harvest Creek Lane Owner Information Permit Information Contractor Information Name: LENNAR HOMES LLC Permit Type:Building New(Residential) Contractor: LENNAR HOMES LLC Class of Work:SFR Construct Address: 4600 W Cypress St 200 Building Valuation:$267,656.40 TAMPA,FL 33607 Electrical Valuation:$40,148.46 Phone: (813)574-5700 Mechanical Valuation:$18,735.95 Plumbing Valuation:$26,765.64 Total Valuation:$353,306.45 Total Fees:$19,616.77 Amount Paid:$19,616.77 Date Paid:2/25/2021 11:19:11AM Project Description v CONSTRUCT SINGLE FAMILY 2,376 SQ FT Application Fees Building Plan Review Fee $684.14 Public Safety Impact Fee-Admin $26.35 Plumbing Permit Fee $173.83 3/4 Water Meter Fee(Calc) $473.78 Water Connection Residential Fee $1,010.00 Electrical Plan Review Fee $120.37 Mechanical Permit Fee $133.68 Building Permit Fee $1,368.28 Park Impact Fee-Single Family/Townhome $769.56 School Impact Fee $8,328.00 Driveway Fee $45.00 Transportation Impact Fee $3,595.68 Plumbing Plan Review Fee $86.92 Mechanical Plan Review Fee $66.84 Public Safety Impact Fee-Police $254.00 Transportation Impact Fee-City $36.32 Sewer Connection Residential Fee $2,090.00 Electrical Permit Fee $240.74 Address Fee $30.00 SIF 1 percent Fee $83.28 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTO SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE1111 fORCITY OF BILLING CONTACT STEVE SMITH LENNAR HOMES LLC 4600 W CYPRESS ST TAMPA, FL 33607 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00002719 02/24/2021 02/24/2021 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-001456-2021 3/4 Water Meter Fee(Calc) $473.78 Address Fee $30.00 Building Permit Fee $1,368.28 Building Plan Review Fee $684.14 Driveway Fee $45.00 Electrical Permit Fee $240.74 Electrical Plan Review Fee $120.37 Mechanical Permit Fee $133.68 Mechanical Plan Review Fee $66.84 Park Impact Fee-Single Family/Townhome $769.56 Plumbing Permit Fee $173.83 Plumbing Plan Review Fee $86.92 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 Sewer Connection Residential Fee $2,090.00 SIF 1 percent Fee $83.28 Transportation Impact Fee $3,595.68 Transportation Impact Fee-City $36.32 Water Connection Residential Fee $1,010.00 39752 Harvest Creek Lane Zephyrhills, FL 33540 SUB TOTAL $19,616.77 REMITTANCE INFORMATION TOTAL $19,616.77 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 February 24,2021 5335 8th Street,Zephyrhills,FL 33542 w- Page 1 of 1 I 5 r PASCO COUNTY, FLORIDA Permit No. 7 Date Permitted Bider Name/Owner Name D(n l�1.(,tlr- Control#' ' County Parcel No. 2 q2-4 1,14 11b WOOD 2,176 b SuDiv: P� - Address/Location 3 / 7 5 Classification/Type of Use s TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑Yes ❑ No How Determined Impact Fee Amount $.- Zone No. TAZ: SCHOOL.IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential t d 23) Collection Fee ExemptYes []No How Determined I - 1. PARKS AND RECREATION FEE• Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation-Total Zone TOTAL AMOUNT . $ 74 9 Exempt n Yes ❑ No How determined i LIBRARY FEE i Land Accounf Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount i RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY W- ILL BE ISSUEQ OR FINAL.INSPECTION PERFORMED UNTIL THE.TOTAL AMOUNTS LISTED HAVE BEEN:PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner.on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 1 J ' 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting =813 �363 2891 Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 39752 Harvest Creek Lane LOT# 0237 SUBDIVISION Hidden River Phase 2 PARCEL ID# 24-26-21-0110-00000-2370 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR e ADD/ALT SIGN 0 Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR 0 COMM = OTHER TYPE OF CONSTRUCTION BLOCK FRAME = STEEL DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R IF 2376 SID FOOTAGE 1936 HEIGHT 1 Story ITrITI"IT'P'PR�IT TTrr 10 BUILDING $ $267,656.40 VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ $40,148.46 ® PROGRESS ENERGY = W.R.E.C. AMP SERVICE PLUMBING $ $26,765.64 �{MECHANICAL $ $18,735.95 VALUATION OF MECHANICAL INSTALLATION 'LrJ =GAS F-471 ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES DO -44— BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypress St.Ste.200,Tamp ,FL 33607 License# FEGC1518166 ELECTRICIAN COMPANY Km:o:nson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skipper Road,Tampa, FL 33613 License# EC13005408 PLUMBER COMPANY Bayonet Plumbing,-Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 34674-5308 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address P.O. Box 5308, Bayonet, FL 346 308 License# CAC058062 OTHER COMPANY I C Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address 4211 Shoal Line Blvd, Spring Hill, F1 34607 License# CCC057991 Illlllllllllllllllllllllllllllllilllllllllllllllllllllllllllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpsster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY,required for all NEW construction. ..4��f�l��l�l��l��l..�f�l..�f�:••r7�'.I.�f�1..��1..�f�1..4�iG.{�1..1..4.1..1..4.I�I�f4.��l..f��f{..���f�:•.l••l•.'r.p�C�:.:�f..4�1� Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy' or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a 11compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirm ore me this Subscribed and sworn to(or a me this GO-Jdf I-L I by Ashlee Callahan 28-Jan-21 by Ashlee Call an Who is/are personally known to me or hasihave PFOdUG84 Who is/are personally known to me or has/have pFedueed tification. as identification. blic o ary Public Commission No. HH 000460 Commission No. HH 000460 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped ELISSAM.HOLLERAN ,��'i��►4 k,, ELISSAM,HOLLERAN Commission#HH 000460 Commission#HH 000460 Expires June 8,2024 `�' Po Exoies June 8,2024 Bonded TNuTroyFalolaeurance$00.385.7018 R„t' DooMThmTrayFainlneuranco000�385.70I8 D Q 0 Single Family Dwelling Plan Review Comments 1. F.F.E; shall be a mim*mum of 8" above the road elevation and an engineered site plan. 2 Lots shall be graded to comply with R401.3 of the F.B.C. 3: Compaction test required.if 24"or more of fill dirt is brought in at any one place. 4. Tie in survey ,required before pouring concrete. 5-. Driveways require.a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection_ . 8: All A.D:.A.'requirements shall be met. .9. No electric,plumbing;mechanical, or framing shall be covered without an inspection and approval first: 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject.to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C: 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1309A 146 Return air in all bedrooms. F.B.C. M162.0.4 1.5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirenients are to be in accordance with R308A of the F.B.C. 17. All means of egress are to:be-in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are'required at all locations requiring an AFC type breaker. 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the'F B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit: This includes all underground.plumbing and electric. 22. All 20M N.E.C. Codes will be enforced. a 21 Tamper- Resistant.Receptacles in accordance with 406.11 ofthe-2016 N.E.0 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 feet atoun&the structure. 25:.R403.5.3Hot water.pipe insulation. Insulation for hot water pipe With'a minimum thermal resistance (R-value) of.R-3 shall be applied to the following: Piping 3/:inch (1.9.1 mm)and larger in.:nominal diameter. Piping serving more than:one dwelling unit. Piping located.outside the conditioned space.. Piping from the.water heater to a distribution manifold:_ Piping located under.a floor slab: Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25.-Blower.door-test shall be provilded before C.O. 26.A copy of the energy cacls shall be.with permit at all times. 27. Cony of final'insulation report shall be provided with permit before final 28.No fence, pool or screen enclosure Is issued with Ih is permit. . F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6t'Edition R.O.W.-Right of Way. A.D.A.-.Americans with Disabilities Act N.E.C.-National Electric Code(2016) . } FORM R405-2020 FLORIDA ENERGY EFFICIENCY�CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941AB sf ADS 1936 4 bed 40GEWH Builder Name: LennarHomes 0237 Street: 39752 Harvest Creek Lane Permit Office: V%Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 61 600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type$1668.7 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 72.70 ft' b.Frame-Wood,Adjacent R=11.0 86.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Numberof Bedrooms 4 d.N/A R= ft2 11.Ceiling Types (2040.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area abovegrade(ft2) 1936 b.Knee Wall(Vented) R=30.0 104.00ft2 Conditioned floor area belowgrade(ft2) 0 c.N/A R= ft2 7. Windows(157.3 sqft.) Description Area 12•Ducts R ft2 a.Sup:Attic,Ret:Main,AH:Main 6 309.7 a. U-Factor: Dbl,U=0.33 101.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.55 33.33 ft2 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl,U=0.33 23.00 ft2 SHGC: SHGC=0.21 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 1.212 ft. a.Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average SHGC: 0.250 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hotwatersystems SHGC(AVG): N/A a.Electric Cap:40 gallons 9. FloorTypes (1936.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservationfeatures b.N/A R= ft2 None c.N/A R= ft2 16.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 57.28 PASS Total Baseline Loads: 58.44 hereby certify that the plans and specifications covered by Review of the plans and ��. IrIE_Sr�? this calculation are in compliance with the Florida Energy specifications covered by this p Code. calculation indicates compliance �'��i� A� with the Florida Energy Code. ti 1nr '' ? ,ti•O PREPARED BY: DG-� .A� Before construction is completed DATE: this building will be inspected for - a. compliance with Section 553.908 hereby certify that this building, as designed,is in compliance Florida Statutes. with the Florida Energy Code. n O CQD yyE � ' OWNER/AGENT: �• V BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Proposed Qn of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405 .2.3 1/12/2021 1:14 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 4 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941ABsf ADS 19364 bed 40GEWH Builder Name: LennarHomes 0237 Street: 39752 Harvest Creek Lane PermitOftice: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Typeg1668.7 sgft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1382.70 ft2 b.Frame-Wood,Adjacent R=11.0 286.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Numberof Bedrooms 4 d.N/A R= ft2 11.Ceiling Types (2040.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area abovegrade(ft2) 1936 b.Knee Wall(Vented) R=30.0 104.00 ft2 Conditioned floor area belowgrade(ft2) 0 c.N/A R= ft2 7. Windows(157.3 sgft.) Description Area 12.Ducts R ft2 a. U-Factor: Dbl,U=0.33 101.00 ft2 a.Sup:Attic,Ret:Main,AH:Main 6 309.7 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.55 33.33 ft2 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl,U=0.33 23.00 ft2 SHGC: SHGC=0.21 Area Weighted AverageOverhang Depth: 1.212 ft. 14.Heating systems kBt Efficiency 34.6 HSPF:8.50 Area Weighted Average SHGC: 0.250 a.Electric Heat Pump 4. 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot watersystems SHGC(AVG): N/A a.Electric Cap:40 gallons 9. FloorTypes (1936.0 sgft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 16.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 57.28 PASS Total Baseline Loads: 58.44 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this 04 = TAp Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for 0 compliance with Section 553.908 I hereby certify that this building, as designed,is in compliance Florida Statutes. 1�,C ��C with the Florida Energy Code. i QD-y E' OWNER/AGENT: BUILDING OFFIPIAI : DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Proposed Qn of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405 .2.3 1/12/2021 1:14 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 4 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941 AB sf ADS 1936 4 bed 40GEWH Builder Name: Lennar Homes 0237 Street: 39752 Harvest Creek Lane Permitoffice: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type�1668.7 sqft.) Insulation Area 2. Single family or multiplefamily Detached a.Concrete Block-Int Insul,Exterior R=4.1 1382.70 ft2 b.Frame-Wood,Adjacent R=11.0 286.00 ft2 3. Numberof units,if multiplefamily 1 c.N/A R= ft2 4. Numberof Bedrooms 4 d.N/A R= ft2 11.Ceiling Types (2040.0 sgft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area abovegrade(ft2) 1936 b.Knee Wall(Vented) R=30.0 104.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 7. Windows(157.3 sgft.) Description Area 12.Ducts R ft2 a. U-Factor: Dbl,U=0.33 101.00 ft2 a.Sup:Attic,Ret:Main,AH:Main 6 309.7 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.55 33.33 ft2 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl,U=0.33 23.00 ft2 SHGC: SHGC=0.21 14.Heating systems kBtu/hr Efficiency Area Weighted AverageOverhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.250 a.Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot watersystems SHGC(AVG): N/A a.Electric Cap:40 gallons 9. FloorTypes (1936.0 sgft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservationfeatures b.N/A R= ft2 None c.N/A R= ft2 16.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 57.28 PASS Total Baseline Loads: 58.44 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this _ ;A0 ' Code. calculation indicates compliance with the Florida Energy Code. !rar '%�:: ;:��"'^�� 0 PREPARED BY: DCz'vl .4614� Before construction is completed "•Y DATE: this building will be inspected for O -1 li X. compliance with Section 553.908 * r, I hereby certify that this building, as designed,is in compliance Florida Statutes. with the Florida Energy Code. COD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler closure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Proposed Qn of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405 .2.3 1/12/2021 1:14 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 4 y FORM R405-2020 INPUT SUMMARY,CHECKLIST REPORT PROJECT Title: 1941AB sf ADS 1936 4 bed 40 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1936 Lot# Owner Name: LennarHomes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: LennarHomes Rotate Angle: 0 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: , Family Type: Detached FL, New/Existing: New(From Plans) Comment: Vinyl windows,shingle roof. CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATIO 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1936 15488 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1936 15488 Yes 5 4 1 Yes Yes Yes FLOORS # FloorType Space Perimeter R-Value Area Tile Wood Carpet 1Slab-On-Grade Edge Insulation Main 156'ft 0 1936 ft' ____ 0.3 0 0.7 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2097 ft2 0 ft, Medium N 0.85 No 0.9 No 0 22.62 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1936 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1936 ftz 0.11 Wood 2 , Knee Wall(Vented) Main 30 Batt 104 ft' 0.11 Wood 1/12/2021 1:14 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 4 } FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block-Int Insul Main 4.09999 14 10 8 0 118.7 ft' 0 0.5 0 2 W Garage Frame-Wood Main 11 16 4 8 130.7 ft' 0.23 0.01 0 3 N Garage Frame-Wood Main 11 19 5 8 155.3 ft' 0.23 0.01 0 4 W Exterior Concrete Block-Int Insul Main 4.09999 47 9 8 382.0 ft' 0 0.5 0 5 S Exterior Concrete Block-Int Insul Main 4.09999 34 8 272.0 ft' 0 0.5 0 6 S Exterior Concrete Block-Int Insul Main 4.09999 6 8 48.0 ft' 0 0.5 0 7 E Exterior Concrete Block-Int Insul Main 4.09999 65 8 520.0 ft' 0 0.5 0 8 N Exterior Concrete Block-Int Insul Main 4.09999 4 6 9 4 42.0 ft' 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .2 3 6 8 20 ftZ 2 N Wood Main None .4 2 8 6 8 17.8 ftZ WINDOWS Orientation shown is the entered orientation(=> changed to Worst Case. / Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.33 0.21 N 23.0 ft' 1 ft 0 in 3 ft 0 in Drapes/blinds Exterior5 2 S 5 Vinyl Low-E Double Yes 0.33 0.23 N 46.0 ft' 1 ft 0 in 0 ft 10 in Drapes/blinds Exteriors 3 S 5 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft' 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior5 4 S 6 Metal Low-E Double Yes 0.55 0.34 N 33.3 ft' 2 ft 0 in 0 ft 6 in Drapes/blinds Exterior5 5 E 7 Vinyl Low-E Double Yes 0.33 0.23 N 32.0 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 416ft' 416ft2 43ft 8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000356 1806.9 99.13 186.11 .1336 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.6 kBtu/hr 1 sys#1 1/12/2021 1:14 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 4 J • FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER:16 35 kBtu/hr 1050 cfm 0.85 1 sys#1 HOT''WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# CollectorModel# Area Volume FEF None None ft' DUCTS —Supply--- ---Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 309.7 ft2 Main 77.4 ft' Proposed Qn Main —cfm 154.9 cfm 0.08 0.50 1 1 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: rj ri Cooling Jan F:b Mar r Oct Nov Dec VHe Jan F enting Jan Feb �X�MMar ar JA Apr May Jun ri Jul Aug rl Sep Oct Nov Dec Oct X Nov DecJun Jul Aug Sep 1A Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8lbs/s .ft. 0 ftz Oft 0.3 Main 1/12/2021 1:14 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Intlnsul,Exterior R=4.1 1382.70ft2 b.Frame-Wood,Adjacent R=11.0 286.00 ft2 3. Numberof units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 11.Ceiling Type and insulation level Insulation Area a.UnderAttic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area(ft2) 1936 b.Knee Wall(Vented) R=30.0 104.00 ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.33 101.00 ft2 12.Ducts,location&insulation level R ft2 SHGC: SHGC=0.23 a.Sup:Attic,Ret:Main,AH:Main 6 309.7 b. U-Factor: Dbl,U=0.55 33.33 ftZ SHGC: SHGC=0.34 13.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.33 23.00 ft2 a.Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.21 d. U-Factor: N/A ft2 14.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.250 8. Skylights Description Area 15.Hotwatersystems Cap:40 gallons a. U-Factor(AVG): N/A ft2 a.Electric EF:0.95 SHGC(AVG): N/A b. Conservationfeatures 9. FloorTypes Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 Credits(Performance method) Pstat b.N/A R= ft2 c.N/A R= ft2 1 certify that this home has complied with the Florida Energy Efficiency Code for Building �JUE S-r Construction through the above energy saving features which will be installed (or exceeded) ..yyo Fo in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant !. rlr,l CQ tures. Builder Signature: Date: 01/29/21 - h a * Address of New Home: 397 Harvest Creek Lane City/FL Zip:Zephyrhills,FL 33540 cOZ)WF t *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 Building Analysis Job: 1941AB sf ADS wrightsofts 9 Date: 1/12121 Entire House By. Dave Aldrich Bayonet Plumbing Heating and Air 8950 New York are,Hudson,FL Phone:727-866-4636 Email:Daye@bayoret-inccom Project • • For. Lennar Homes Desi gn Conditions Location: Indoor: Heating Cooling Tampa IntemationalAP,FL,US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD(°F) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(grAb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/V Btuh %of load Walls 5.0 9460 31.1 ucts Glazing 20.9 3262 10.7 Doors 19.7 726 2.4 wails nfltration Ceilings 1.3 2429 8.0 Floors 4.3 8258 27.2 Infiltration 2.1 3056 10.0 Ducts 3221 10. Piping 0 0 0 Humidification 0 0 Floors Ventilation 0 0 Glazing Adjustments 0 Doors Total 30412 100.0 Ceilings Component Btuh/F Btuh %of load Walls 2.4 4607 17.4 Walls Glazing 49.0 7645 28.8 ntemal Gains Doors 15.4 569 2.1 Ceilings 1.7 3358 12.7 Floors 0 0 0 Infiltration 0.5 684 2.6 Duds 3628 13.7 Ventilation 0 0 Ducts Internal gains 6030 22.7 Glazing Blower 0 0 Infiltration Adjustments 0 Total 26521 100.0 Doors Ceilings Latent Cooling Load=4280 Btuh Overall U-value=0.103 Btuh/f l--°F Data entries checked. wrightsoTt- 2021-Jan•1213:01:12 MCAk •� Rigtt-SLite®thirersal202l 2l.O.O2 RSU18533 Page 1 equpmert11941sfADSTampaVW3tonCarrier.np Calc=MJB Front Door faoes:NW Prot S Job: 1941AB sf ADS wrightsoft® Project Summary Date: Ill2121 Entire House By. Dave Aldrich Bayonet Plumbing Heating and Air 8950 New%rkave,Hudson,FL Phone:727-86BA636 Email:Dave@bayoneWrcwm Project • • For: Lennar Homes Notes: vinyl windows Shingle roof Design Information Weather. Tampa IntemationalAP,FL,US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 27191 Btuh Structure 22893 Btuh Ducts 3221 Btuh Duds 3628 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfin) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30412 Btuh Use manufacturers data y Ratelswin multipplier 1.00 Infiltration Equipmengsensibleload 26521 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construcfion quality Semi-tight Fireplaces 0 Structure 3619 Btuh Ducts 660 Btuh Central vent(0 ctm) 0 Btuh Heating Cooling (none) Area 1936 1936 Equipment latent load 4280 Btuh Volume(ft') 16360 16360 Airchanges/hour 0.26 0.14 Equipment Total Load(Sen+Lat) 30801 Btuh Equiv AVF(cfin) 71 38 Req.total capacity at 0.85 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade PERFORMANCE 15 HP Trade PERFORMANCE 15 HP Model 25HBC537AP030 Cond 25HBC537AP030 AHRI ref 204837926 Coil FX4DNF037L AHRI ref 204837926 Efficiency 8.5 HSPF Efficiency 12.5 EER,16 SEER Heating input Sensible cooling 29750 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 5250 Btuh Temperature rise 26 °F Total cooling 35000 Btuh Actual airflow 1200 cfm Actual airflow 1200 cim Airflowfactor 0.039 dm/Btuh Airflowfactor 0.045 cfmBtuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point=29°F Backup:n/a n/a Input=5 kW, Output=17061 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsot t' 2D21-Jan•12 13:01:12 ^^• •-w^--••�w- Rigtt-SLite@)Uriversal202l 2l.O.O2 RSU18533 Page 1 ACM equpmert%1941sf ADS Tampa VW3tonCarriernp Caic=MJ8 Frort Door faces:NW Manual S Compliance Report Job: 1941AB sf ADS -�+ wrightsofto Date: 1/12121 Entire House By. Dave Aldrich Bayonet Plumbing Heating and Air 8950 Newlbrkaye,Hudson,FL Phone:727-868-4636 Email:Dave@bayonet-inccom Project • • For. Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 26521 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 4280 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain; 30801 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer. Carrier Model: 25HBC537AP030+FX4DNF037L Actual airflow: 1200 clam Sensible capacity: 29750 Btuh 112%ofload Latent capacity: 5250 Btuh 123%of load Total capacity: 35000 Btuh 114%ofload SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 30412 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer. Carrier Model: 25HBC537AP030+FX4DNF037L Actual airflow 1200 cfm Output capacity: 34600 Btuh 114%of load Capacity balance: 29 °F Supplemental heat required: 0 Btuh Economic balance: -99 of Backup equipment type: Bee strip Manufacturer. n/a Model: n/a+n/a Actual airflow: 1200 cfin Output capacity: 5.0 kW 56%of load Temp.rise: 13 °F Meets all requirements ofACCA Manual S. C * Wrlghtsoft- 2021-Jan-1213:01:12 •�, ,�. RigK-Sate®Uriversal 2021 21.0.02 RSU18533 Page 1 _equpmerfi1941sfADSTampaV�� W3tonCarrierny Calc=MJ8 Frorl Door faces:NW PLOT PLAN SKETCH ONLY SEC. 24 TWP. 26 S, RNG. 21 E. NOT A BOUNDARY SURVEY LOT 237 BEARING BASIS: HIDDEN RIVER PHASE 2 WEST BOUNDARY OF SUBJECT PLAT BEING N 0923'02" E PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND PRELIMINARY DRAWING: N NOTES TAKE PREFERENCE. THIS PLAN IS FOR PERMITTING PURPOSES ALL DATA SHOWN HEREON BASED ON THE ONLY, NOT FOR CONSTRUCTION. VERIFY -0 ENGINEERING PLANS OF KIMLEY-HORN AND ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ASSOCIATES, INC., PROVIDED BY LENNAR HOMES. LEGEND: 10' PUBLIC UTILITY EASEMENT PROPOSED DRAINAGE FLOW (00.00) = PROPOSED GRADE < E-00.00 0 EXISTING GRADE En NOTES: t LOT GRADING TYPE = A PROPOSED PAD ELEVATION FRONT SETBACK = 20' SIDE SETBACK = 10' REAR SETBACK = 10' 4) .00 amp. �• •�� ./,'. .�� `O" IN t! 0% LOT 238 j, ID b,\ 1�5 PC(P) N 43 >r, -(72-471) LOT 255 ON LOT AREA CALCULATIONS LOT =--.§.6-0L0--Q9L-SQ. FT. LIVING AREA =--1.UA---SQ. FT. LOT 236 I\ENTRY =--ZL----SQ. FT. GARAGE =--.±1-EL--SQ. FT. 0. COVERED LANAI ---SQ. FT. PATIO --_-SO. FT. CONC. DRIVE -A!!L---SQ. FT. 72.32)- A/C & CONC PAD =--k_--_-SO. FT. PRIVATE SIDEWALK --__SO. FT. LOT 256 IMPERVIOUS = 44----7. 1 2Z9�;L--S _ O. FT. C j SOD i0L--SQ. FT. OFF LOT AREA CALCULATIONS LOT 25711i RIGHT OF WAY FT. IC DRIVE APRON =--2fL---SQ. FT. PUBLIC SIDEWALK ---SQ. FT. < SOD ---SQ. FT. L13 3: o TOTALS AREA =--M%q--9CLsQ, FT. PROPOSED: > DRIVEWAY FT. ca SIDEWALK FT. LOWEST FLOOR ELEVATIONS: SOD =--3982--SQ, FT. LIVING AREA: 73.00' 0. GARAGE AREA: ry DESCRIPTION: ELEVATIONS REFERENCED TO LOT 237, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE 2", NATIONAL GEODETIC VERTICAL AS RECORDED IN PLAT BOOK 079, PAGES 102 THROUGH DATUM OF 1929. MEAN SEA 110, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101C 0458 F EFFECTIVE DATE: 09/26/2014 Square Feet; 6600.00 LENNAR HOMES LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, �= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= N CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE "CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED o PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT ,4- REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK No.4493, TBM= TEMPORARY 4 BENCHMARK, LIM= UTILITY POLE, W/F= WOOD FENCE z JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS SURVEYORS AND MAPPERS t 911 WEST ST. PETERSBURG DRIVE Checked By: JRB ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30' NOT VALID WITHOUT ORIGINAL SIGNATURE LOT PLAN 12/30/2020 ACS AND SEAL OF A FLORIDA LICENSED W MAPPER Revisions: SIGNIA E D 7E JOH R. BEACH 2 A FLORIDA REG.\LAND SURVEYOR No. 2984 LB#4493 t r r 224 73,0,5 FE DEL ra, r ',r , ' r' r �x V V1° 4-09 '� 251 'a' t �- r-------_._. �`�',.^' �•,�p�eepp � r r`°., ,. .>✓' :r•''.. �,. ;.� „+r^"'' �•+"' �,.• 1 �i+ltc:F.� Y%Y"�,SL,. �., .. r tS^k" .+�✓` r��t r, r r"• ` t ✓ y.'� ^•,, ,,,a rr r i` _ 6 x ` F ,- r"+`^. "•-/P��' .- ra r , �. _. ., __„ ,. r �,__ J r.r 7 .60r t' i •f 'd r 4 , BEd '� r .`•. �`f o` �..,. , , +, r r r r EL t'" 2 + ;r i`. r r r r ..r r 7�a h f r . ` .�. r ;r : � r,r r , - F * r r M1 . :8L r 23 r `�'t r rr FEL err ,�- �� �ZU3 4 � r L.Gr-•"-.x�',,,r� q � � r� � ,.. .r^'��'��W .. �,,:''`s,y r Et �a 2 / D5 �r A �, r .,^ , r r r pa-50 rr�rJc rrr FF ELyV � `4 �•F,r Y xas rr - .•� r FEES r r 2Ci2 '^ f� ~� $1 rr _ . � �a� r��_ r-..'� ,. 1 r PF 1- f' r r201 ��' �',r '' �'' r ..r ,r ��_ - '�. -' ..,� d `r 73.FlY. '� r• a4 � - , a+ � W rot ray r f "'''rr r FF ,r':ar T3, i ,f.. £r:: •., r �r g ry �"`l 73,4 tirA r ~� _ D EL r . •~ rk ����'.,. -' fa Y °a ='w, ? ,,r ° _� __ .y u - ' r r�" �n -r� , '02 Q ti\rr A '` r »� rj Aq r FF�.. -' C•L f ,/,'••1,W' S ,�^y' r y ` y'TM rr r 7 ^r ,,,, „_..•,,..-� ,r ," r r, �.£ .. r r +'{ �R" x,•a '.«... _ p �•y i !(R�¢ 1 r t y •� �'-� W V 4 M pb y, Y• .i \i.r `d ~ }V��, ` yry Syr. r r .. �r7 -•..y+r'V R !.. k 49 A, v V �r xt, q.., ux,.,. .rl;,:,l I .+^``✓'' „ b...`4` ?!A`rM W 4 �'+ '••+ V b V-.'.�"�V + Kx °' W. ?111 d M :r {Z.vYI r p - `�d f• y "r�y�` la��J rr -..-q. ••�.- J'yf'y -"" w T y, * +W,..,..Y 4 = W+• +M1 + Y" �Wv:•;� W '� '�' 1,A � P,`rt''`r *� ys5-1 y � W 4 w «Y.• Y w Y y W + �� �'rq 1 \ A 'r „ Y •.. .. � p �S„a � g � t� ,�{gJ 't y .,.,y,�c,. •} 'P 'i " a'�^`"'-v Y y' +!'• 'a' FF Et V f -` _ y� M "R '' f ww w.' ' Y W�« +W a 4 a Y = y" p W w� W •w f G >r•,.r .�s r., ,n- �.-"" ~� ;., `•�y/.�� r r rF `' r r lr r 4 � y 4 + -� w w = '� ` a �..�._+-.�-- �F � Y^' V' y, '^•-w. ~ + ,l^....4.. .>".,=m•.,i:, W �.y �•-"•'••� y�y�y x,4� +✓'" F ''••~ ^•• S p `t ry`��!] � �'' s't N� , + + W a y V + 4 4 ,i-"°.,,..4 4 yr W b ♦ i = �'..y"" W za ' .#�-'>" l rr r; ,M V Y V " nW-^"'Y�'a'Y ` tr •„e`i, iR .'t - f' ,' ..^"'" y, tr y '1• W W # 'L a •Y e µ V a,.,,, " b Y'/^Y A .. Nay _ gFgF'�E�ty t{�}r � ��/��+y rr r t '' \�2`� r �" a + + +. e r •, � «� + � W./ ' . Ii.VV 1 `trr 9 M �;yrt�r A A � 4 �,. .. Y.b ♦e +.v r4r•--�. '}`�+'�.v y•4•, 1• �,.` ♦ L gy .y Y ,. .+"..,f'X' i " ,� ."'- y� •- K V w x.a-^ '°"."'K�•M� b ' :pa jy! ••rti r a ♦w + Y V + > ",,.e `0..-s.y�~ +/ .Y• �' t e»+ "'~ A'I W W we' -�• '+...,,_r...,.-^ _,r"-d",,..M A r \ ,4 �,,•r,.-=' W W..>�',"TT-»x II y � � My � tr �•�^Y " Y .4_..b W e � Q w a �`,"•^-.-....,••.•�'�, 41vr•'• r s' �a � i. 1• � ,, �t i`,�i!''h �jiw �`• y 4 v' tr " r ,' . +, a'^-. + w a W + =a`. VF5L '•r `� [�`�. r` � � + -. "�v•,.y^ y W w� W p `.+ �� 4 «..•.-s ...y., ^' W �%--.�• r,. ,1 94 -�, 'sy;cY y r ,y s r�W w �'-,�„..-.� b e ,+, tr s .^m e '�' W ,�, _ ""u::�•+ e p ,y raa r" i ,/.1.• M +r W v ♦ ' W �, m 4 W .... V 4 ....Y.�,cW-v. ^..t"%^� ss",,..W �, iJ"�y�}4r i r �1 ri� ``rd ry w w~< W Y w».ww ♦ W e e ! 4 W V a + W Y W y p * w Y+-..W».».�.. 4 4 4 V 4493 ,]r /°�#' •Y �, M 1 W n Y a = +�" y. y, +W f Vr 'b .G V .`tr a+,!, ';.W w..V,,. w yhs,.tye +7' W p y +,r, ...''+' r � r� h' r �„e"�- 4�w a w+� V , �+ v�ry 4 w W ��• a �`r, e W ..,y; v� + a :+•^� ' 92 '.,.-:".-' �g �k r i r t r �q�,,/'J w W y. ••+)� `V r + W Y 'W . u .. " w-V + W w . ,-'�' .a �._''•."' '�~ � ar 4 �r �},� G'"" ` + p r. y 1 '" •>�+ .,, � e' K, w a w ! •" +..r ,y Y a _ 5 ••. ,-Fj,,. T•,°"'\ %x i �+�^ r �' y �' %x' Y y w + @ w f W a p 'd, M jip , _ (� • \ 1r rid =+ "+ t c .'b W W a ;# ,; 'IY` �e r � r r FP E�L L r4`` Yy194�• ■4je ,�,.ri �,1c oeu 4 �(i� yY w WwYe + at +_ +_ rs •_ r . T ' ff„✓'•x4 „ 1 \\ t`r` .,+'".,``^ "r µ= ," » w Y a w +., Y + °'' „?fi.f + W ui+e o .-. rY „A.......-m ^'_•=• {r,,.�"' � A� ✓• + }4 + + w w .y. �,.d+-.w LL w + i 4 i t{ ., • r !4,-.,m P P�ti•'� • p W v +' w yp ,Y + _ w ,•, w �" p P _.M."`...-w'. ,.,."..- w•_- ��F�.,,r � w PASCO COUNTY Receipt Date: 04109/2021 pABUILDING CONSTRUCTION SERVICES Receipt Number. 20'34474 I 1 Is C .8731 Citizdhs DrIV6 COUNTY RbRIE14y" Suite 230 OPEN SpAcm.VIBMW PLACES. NeW Port Richey,FL 34654 727-847;-8126 iNOT A F""'ERMIT Paid By Check# CC Auth# Cashier ID Workstation Check 01591462 MLARNOLD BCCCP47L Foe Description Amount Paid Impact Fee Residential Solid Waste Single Family 50.58 Total Payments: $50.58 Pa or. Address Phone LENNAR Comments: 24t26-21-01 10-0000o-2370 1456 39752 HARVEST CREEK LANE While you will be paying your 6111 with Pasco County Building Construction Services,the full-arnount of the credit card or 6-check foes,NOT shown above,Is collected by First Billing payment services. myrapor(VrepotfsllproductionIPASCOICustomer Receipt vlfrpt Print Date: 04/09/2021 Page 1 of 1 PASCO COUNTY i, Receipt Date: 04/09/2021 PASC BUILDING CONSTRUCTION SERVICES j Receipt Number: 2034474 8731 Citizens ens Drive 'COUNTY FLORI DAN Suite 230 OPEN SPACES.141BN.NT�I)l AM. New Port.Richey,FL 34654 ..727-847-8126 NOTA PERMT Paid BV Check# CC Auth# Cashier ID Workstation Check 01591462 MLARNOLb BCCCP47L Fee Description Amount Paid Impact Fee Residential Solid Waste Single Family 50.58 Total Payments: $50.58 ----------------------------_ ------ ----------Address------------ Phone LENNAR Comments: 24-26-21-0110-00000-2370 39752 HARVEST'CREEK LANE While you will be paying your I bill with Pasco County Building Construction Services,the fu aniouni of fhe cr dit card or e-check fees,NOT shown above,Is collected by First Billing payment services. ------------ ------------ ------------ ------------—------ - --------- --------- ------- ------------— myrepollslreportsllproductionIPASCOICustomer Receipt Of rpt Print Date: 04/09/2021 Page 1 of 1