Loading...
HomeMy WebLinkAbout21-1476 a City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 ELCMISC-001476-2021 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 02/24/2021 Permit Type: Electric Service Replacement/Misc Property Number Street Address 24 26 210090 00000 0350 3209 Moulden Hollow Drive Owner Information Permit Information . Contractor Information Name: VALERIE JOHNSON Permit Type:Electric Service Replacement/M Contractor: GENESIS ELECTRIC Class of Work:Add/Alter Residential SERVICES Address: 3209 Moulden Hollow Dr Building Valuation:$25,156.00 ZEPHYRHILLS,FL 33542 Electrical Valuation:$3,000.00 Phone: (262)358-3054 Mechanical Valuation: Plumbing Valuation: Total Valuation:$28,156.00 11/J Total Fees:$331.17 Amount Paid:$331.17 Date Paid:2/24/2021 1:46:13PM Project Description INSTALLATION SOLAR ROOF MOUNT Application Fees Electrical Plan Review Fee $27.50 Building Permit Fee $165.78 Plan Review Fee $82.89 Electrical Permit Fee $55.00 REINSPECTION FEES: (c)With respect to Rein spection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CM06R SIGNATnE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER I 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting ( 813 ) 808 _ 0218 I # a1€ F € 111 I V 5 T # V 9 V V I W € aia € Owner's Name Valerie Ann Johnson Owner Phone Number (262) 358 - 3054 Owner's Address 1 3209 Moulden Hollow Drive,Zephyrhills,FL 33540 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number �., Fee Simple Titleholder Address JOB ADDRESS 3209 Moulden Hollow Drive, Zephyrhills, Florida 33540 LOT# 35 SUBDIVISION HIDDEN RIVER PH 1A PARCEL ID-4 24-26-21 -0090-00000-0350 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR 8 ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM = OTHER TYPE OF CONSTRUCTION = BLOCK FRAME = STEEL DESCRIPTION OF WORK ROOF MOUNTED SOLAR PANEL INSTALL BUILDING SIZE SQ FOOTAGE HEIGHT €€€€ €€€€€ c€€€€€€€€€€€€ t€€€€€€€€€ktttt€€€€€€�€€€€€ €€�€€€€�€€€€€€€ €€€�€�€� BUILDING $ 25,156 VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ 3,00 AMP SERVICE = PROGRESS ENERGY W.R.E.C. =PLUMBING $ life MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO I 1 I J BUILDER COMPANY US SOLAR SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address 2732 Broadway Center BLVD.Brandon, FL 33510 License# CVC57002 ELECTRICIAN COMPANY GENESIS ELECTRIC SERVICES LLC. SIGNATURE REGISTERED I Y/N FEE CURREN Y/N Address 2825 Murray Pass, Odessa FL 33556 License# EC13007122 PLUMBER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/N FEE CURREN Address License# llII II I III I tIII11II Is It I! I< I III IIa's € II I I€ & II< II IIItI tf I I I I I I I€ I I I I fill I RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW Sola" r Local Experts who Care 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions'which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowners Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTI FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by 02/04/2021 by Seann Gates Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. DL as identification. Notary Public otary Public Commission No. Commission No. GG 9 9064 Jason S. Monchgesang Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped JASON S. MONCHGESANG g=° Notary Public-State of Florida Commission # GG 959064 ,; °a�:� My Commission Expires ���i°ril1%1�� February 17, 2024 olar Local Experts who Care DocuSign Envelope ID:F70EI985-5D70-4A1B-BE9E-4186B4DE8816 I I CONTRACT FOR SALE AND INSTALLATION OF A 7.04 SYSTEM (hereinafter the"System")by and between US Solar Squared,LLC(hereafter"Seller"whose address is below provided)and Valerie Ann Johnson (hereinafter jointly or severally"Buyer")whose address is 3209 Moulden Hollow Drive Zenhyrhills Florida 33540 according to the terms and conditions hereafter stated. Buyer understands and agrees that this contract is binding only when accepted by Seller by having its duly authorized company officer or member execute this contract.Buyer further understands and agrees that the full contract price for purchase and installation of the System shall be the following price $29,156.00 unless amended by subsequent agreement of the parties. Buyer further acknowledges and agrees that Buyer is not to give the sales agent presenting me this contract any money or check as the sales agent is an independent contractor and is not authorized to collect money on behalf of Seller. TERMS AND CONDITIONS MECHANIC'SLIENNOTICE: ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001 - 713.37, FLORIDA STATUTES),THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND ARE NOT PAID IN FULL HAVE A RIGHT TO.ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY IF YOUR CONTRACTOR OR SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUBSUBCONTRACTORS, OR MATERIAL SUPPLIERS. THE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FORM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE ;TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY. BUYER'S RIGHT TO CANCEL This is a home solicitation sale,and if you do not want the goods or services,you may cancel this contract by providing written notice to the Seller in person,by telegram,or by mail.This notice must indicate that you do not want the goods or services and must be delivered or postmarked before midnight of'the third business day after you sign this contract. If you cancel this contract,the seller may not keep all or part of any cash down payment. Date Buyer signed this contract is: 1/18/2021 _. If Buyer decides to cancel this contract,Buyer will send the cancellation notice to Seller at its address provided below within three business days after this date. By signing below,Buyer agrees to the tenns and conditions stated above and on the reverse side of this page. Buyer(s):(If n7arr'ed,Rouse must sign as well). QoeuLigned'6y: By �a�riLro,4oLor '.. By 6FC018B65D0472... ACCEPTANCE:By signing below,Seller hereby accepts Buyer's offer according to the terms and conditions stated above and on the reverse side. D"U gned 6y: US Solar Squared,LLC By�C � /_',.L e 2732 Broadway Center Blvd. Seann Gates,President Brandon,Florida 33510 20A494735BBB49A... State License#CVC57002 Date Accepted 1/18/2021 CHAPTER 558 NOTICE OF CLAIM CHAPTER 558, FLORIDA STATUTES, CONTAINS IMPORTANT REQUIREMENTS YOU MUST FOLLOW BEFORE YOU MAY BRING ANY LEGAL ACTION FOR AN ALLEGED CONSTRUCTION DEFECT. SIXTY DAYS BEFORE YOU BRING ANY LEGAL ACTION, YOU MUST DELIVER TO THE OTHER PARTY TO THIS CONTRACT A WRITTEN NOTICE, REFERRING TO CHAPTER 558, OF ANY CONSTRUCTION CONDITIONS YOU ALLEGE ARE DEFECTIVE AND PROVIDE SUCH PERSON THE OPPORTUNITY TO INSPECT THE ALLEGED CONSTRUCTION DEFECTS AND TO CONSIDER MAKING AN OFFER TO REPAIR OR PAY FOR THE ALLEGED CONSTRUCTION DEFECTS. YOU ARE NOT OBLIGATED TO ACCEPT ANY OFFER WHICH MAY BE MADE. THERE ARE STRICT DEADLINES AND PROCEDURES UNDER THIS FLORIDA LAW WHICH MUST BE MET AND FOLLOWED TO PROTECT YOUR INTERESTS. Installation 11.10 DocuSign Envelope ID:F70E1985-5D70-4A1B-BE9E-4186134DE8816 1.INCORPORATION:The parties agree that the terms and provisions set forth on the front page are incorporated into this contract by reference. 2.JOB SPECIFICATIONS:The specifications for the System are set forth in the work order attached hereto and incorporated herein by reference. The contract price set forth on the front page shall include i) the purchase of the System described in the work order; ii) the installation of the System by Seller or its subcontractor, and iii) costs of supplies and materials used in the installation of the System. Buyer agrees to be fully responsible for all sales taxes,if any,levied in connection with the purchase and installation of the System.Unless otherwise set forth in this contract, the installation shall occur at the address of Buyer stated in the preamble.It is the obligation of the Buyer to provide Seller or its subcontractor utility services so that Seller may properly install the System. 3. SERVICE AGREEMENT: Buyer agrees that this is not a contract governed under Chapter 672,Florida Statutes, as this is a contract primarily for the installation of the System.Seller is not responsible for securing for Buyer any Federal Tax Credit,State or Power Company rebate,if any. 4.RESTOCKING FEE:Except for instances caused by US Solar Squared,LLC,US Solar Squared,LLC will charge the customer a restocking fee of 15%for any cancellations after the recession period ends. 5.FINANCING: If Buyer does not have the funds readily available to pay the contract price following the installation of the System,Buyer agrees to apply to a financing company to pay the contract price on forms provided by the financing company. Such application shall be undertaken by Buyer independent of Seller whom Buyer agrees is neither Buyer's agent nor the agent of the financing company in connection with any loan application. If Buyer applied for financing in connection with this contract, Buyer understands that Seller will not accept Buyer's offer unless the financing is approved by a duly licensed financing institution in good standing in the State of Florida. If Seller accepts Buyer's offer and thereafter learns that the financing has not been issued, or if issued is then withdrawn by the financing company, Seller may terminate this contract without any liability to Buyer. 6.WARRANTY: Seller agrees,on condition that the full contract price has been paid on completion of the installation of the System,to warrant the operation of the System for one year following its installation.If,during this one year period,the System or any its components should fail to operate in accordance with the manufacturer's specifications, Seller agrees to replace or repair the System at its sole cost and expense, including parts, supplies and labor.US Solar provides a 10 year Workmanship Warranty and a 5 year Roof Penetration Warranty. 7. LIMITATIONS OF WARRANTY:The warranty of repair and replacement given by Seller in paragraph 5 above shall be null and void if Buyer or anyone else shall damage or improperly maintain or operate the System, or should injury or damage be caused the System by fire,rain, freeze, storm (including hurricane)or any other force majeure or act of God. Furthermore,Buyer acknowledges and agrees that the proper maintenance and operation of the System is dependent upon the conditions of proper design,construction and maintenance of Buyer's property and building(and pool if applicable)where the System is to be installed and operated,and that the plumbing and electrical services serving Buyer's property are adequate to maintain and operate the System as intended once installed. If the System fails to operate within the manufacturer's specifications because of the failure of any of these conditions, then the warranty of Seller is null and void. Furthermore, it is specifically agreed that SELLER DOES NOT PROVIDE AN IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AS TO THE SYSTEM BEING INSTALLED. 8. LIMITATION OF LIABILITY:The exclusive obligation and liability of Seller, and that of its officers,subcontractors,agents and employees, to Buyer for any direct, indirect or consequential damages arising from or related to i) the failure of the System to operate according to the manufacturer's specifications, or ii) damage to the property or building of Buyer due to a defect in the System or to the negligent or improper installation of the System, or iii) for any personal injury (including death) caused Buyer by a defect in the System or its improper or negligent installation is limited to the contract price; and,except to that extent,the Buyer hereby releases,discharges and waives any other claim or demand for damages, injuries or losses of any kind or nature, or any other suit or action that Buyer may or does have against Seller, or any of its officers, employees or agents,based upon a defect in the manufacture, installation or operation of the System, including any claim, demand, suit or action Buyer might or could make or bring for the negligent installation of the System by Seller and its officers, subcontractors, agents and employees. Furthermore,neither Seller nor any of its officers, subcontractors, employees or agents, shall be liable for any damage caused to the building or property of the Buyer during the installation of the System unless Buyer serves written notice on Seller of the alleged damages within five (5) days following installation. 9. ARBITRATION:Any dispute arising under or related to this contract, including any tort action arising out of or related to the installation of the System,shall, if not resolved by the parties,be referred to binding arbitration. Only a court of competent jurisdiction shall have the right to determine if the subject matter of the proposed arbitration comes within the terns of this arbitration provision if the parties disagree as to the arbitrability of the matter. Arbitration shall be conducted in the Hillsborough County, Florida in accordance with Commercial Arbitration Rules of the American Arbitration Association then pertaining,and judgment on any award rendered in such arbitration may be entered in any state or federal court. The parties agree to allow the American Arbitration Association to choose the arbitrator,and its decision as to the selected arbitrator shall be binding unless either party can show the chosen arbitrator to be incompetent or biased for or against any party.Notices in connection with such arbitration must be served by personal delivery or certified mail, return receipt requested, on Seller at its address stated on the front page hereto. Costs of arbitration, including the filing costs and related arbitrator fees, shall be awarded as determined by the arbitrator; but only a court having jurisdiction over the parties may make a determination whether attorneys fees are recoverable, and if so, in what amount. Notwithstanding the foregoing,the parties hereto,and those in privity with the parties hereto,agree that any action or suit to foreclose a mechanics lien brought pursuant to Chapter 713,Florida Statutes,shall be exempt from the application of this arbitration agreement. 10. MERGER:This contract, if accepted by Seller,represents the final expression of the representations,terms and covenants of the relationship established between Seller and Buyer and the installation of the System. Buyer agrees that Buyer is not relying upon any other representation or statement made heretofore by any sales agent,independent contractor or representative of Seller to Buyer as an inducement to enter into this contract, and Buyer releases Seller from any other inducement or representation that is not included herein,even if such representation was material to Buyer's decision to enter into this contract.Buyer agrees that only an officer or member of Seller has the authority to bind Seller to this contract,or waive or modify any of its terms. Furthermore,Buyer understands and agrees that no sales agent,independent contractor or employee of Seller has the right to promise Buyer that any rebate of any sort will be made oi•given with respect to the purchase or installation of the System. 11.GOVERNING LAW,VENUE:This contract is to be construed tinder and governed by the laws of the State of Florida.Any action,suit or other proceeding between the parties hereto, whether or not such action, suit or proceeding arises under this contract, shall be brought in Hillsborough County,Florida; and the parties agree to waive venue in any other county.However, if the suit or action includes a mechanic's lien foreclosure, venue shall be placed in the county where the System was installed. 12. NON-ASSIGNABILITY:Buyer may not assign this contract,nor any of Buyer's rights hereunder,to another. 13. PAYMENT:Buyer agrees to pay the full contract price on completion of the installation of the System,time being of the essence. 14. DEPOSIT:If the work order given in connection with this contract provides for Buyer to give Seller a deposit as a condition of Seller accepting Buyer's offer, Buyer shall have the right to withdraw its offer if the amount of the deposit is not agreeable to Buyer. Payment of the deposit to Seller's employee shall be conclusively deemed Buyer's agreement to enter into this contract and pay the deposit. Despite accepting such deposit, Seller shall not be obligated_to apply for any permit within thirty days of accepting the deposit or coniinence work within 90 da_ys of the perniit(s) being issued,and the parties hereto waive application of Florida Statute§489.126(2)to the extent it applies to this contract,if atall. 15. ACCEPTANCE: If Seller does not provide notice to Buyer that Seller has accepted Buyer's offer within forty days following the date Buyer signs this contract,Buyer's offer to enter into this contract shall expire.However, should Seller proceed to install the System following expiration of the acceptance period with Buyer's knowledge and approval,then the parties hereto shall be bound by the terms of this contract. Installation l 1.10 INSTR#2021022793 OR BK 1 0272 PG 304 Page 1 of 1 02/03/2021 11:25 AM Rcpt:2256650 Rec: 10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles, Esq., Pasco County Clerk&Comptroller Permit No. NOTICE OF COMMENCEMENT smte a T THE UNDERSIGNED hereby gives notice dot tmprowanam will be made to certain real property,and In e000rdeno s with Chapter 713,Florida Statutes, the fdbwhg Information is provided In this Notice of COMMW4an8111: 1. Description erMopW..PmcelldatstketlonNo, ;;Ii-1-PIER-a1-()()qn 000-D SO StreetAddreas: �.00l Iv10wdkvn s1\, E I— ).--�•J `v 2. General Desaipdon of Improvement 3. Im(amatlop or Lessee irft nation it Me Leases contracted forthe improvement �U1r' -T©Yr\rrsc,v-\ _3gc,g bLm61'Ev\ BOXIC."u') Address �//1 City State Interest inPropety:_I a)cI-,/. - - Name of Fee Simple TdMhddar. C (ifdilfaerd flan Owner fisted above) Address4. Contractor. S L'I of city State-- contractor'sstate Ta,aphone No.: -SC�U-�3�r—3U3c _AddrwCity 5. stew. Name Adder City state Amountof Bond:s Telephone No.: 8. Lends. Name Address City State Lenmra Teirptana No.: 7. Persoru vAMtn die State of FIaMe daalateled by the owner upon whom notices or other d0ctanents may be served as pmvldm by Sed on 713 Ml)(a)(T),Florida StrIsAw: Name Address city state Telephone Number of Designated Person: a. In addition to h1m6W.the MW designates of to reoelve a ropy of the Lienoh Notice as provided in Sectim 713.13(1)(b),Florida Statutes. Teteph m Number of Person or EMRy Designated by Owner. a. 00ratlon date of Notice of Commencement(Iha aohation date may not be before the completion of construction and final payment to the aontractac,but will be one year from the date or ricaVitg unless a dilremrd data to spedllad: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE E)RRATION OF THE NOTICE O COMMENCEMENT RESULT INt YOUROPAYIMPROPER G TWICE FFOOR IMPNTS ROVEMENTNDER S TO YOUR PRROPERTTY. A NOTICE OFOCOMMENCEM COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WmH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Underpenatty a pahuty.I declare that I have reed Me foregoing notice of commenoemem and that the facts stated therein am true to the best or my IataNetlgo and txttlef. STATE OF FLORIDA COUNTY OF PASCO -x t /24 5ptSao amr owf ,^ Of Less",or VWrW8 eaeee'e Auamlxed oftedollacti lni" r SlgmaWs Tide/ORea The f "oinghwtnan9MW23adMMAedgedberoremeWs&�hvyorinvlt a6u 20 Lby \11-Au'Li 1rAA AS��✓\_ as h�V>ul 2(JJ.)0_k 7 (type of authedty,e.g.,of m.trust..aaonnW In fed)for of on whom Iqvunent was axecvtW). Persatmy Known O 4B Produced�ldemrtcadord Notary Type of Identification Produced Name(Print) S. Ml e.•,Lt GSc vt `oi`rti'v'"•''r•., JASON S. MONCHGESANG Notary Public-State of Florida •-` Commission C GG 959064 M Commission Expires wpdam rtotic�rnmertcertertt�ct)53o4a ''fir°;,�'`'� My 17.2024 7.04kW SOLAR ARRAY PLANS FOR PROJECT DESCRIPTION: GENERAL NOTES: 22 MODULES - MISSION SOLAR: MSE320SR8T 22 INVERTERS - ENPHASE: IQ7-60-2-US 1. THIS IS TO CERTIFY THAT TO THE BEST OF -0 T VALERIE ANN JOHNSON MY KNOWLEDGE AND BELIEF, THESE PLANS 'Q •. CONFORM WITH FLORIDA BUILDING CODE 2020 ��O GOVERNING CODES: WITH ALL SUPPLEMENTS AND ADDITIONS. 3209 M 0 U DEN H 0 L LO W D R 2020 FLORIDA PLUMBING CODE, 7TH EDITION 2. ALL PRODUCTS TO BE INSTALLED PER 2020 FLORIDA BUILDING CODE, 7TH EDITION MANUFACTURER'S WRITTEN SPECIFlCATIONS. 2020 FLORIDA MECHANICAL CODE, 7TH EDITION I, ANDREW D. HALL PE# 87479 AN ENGINEER Z EP HYR H LLS, FLO R DA 33540 NNEC FPA 2018 201LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FBC, FBC 107. TYP. EAVE DISCONNECT Wind Design Data Wind Speed 140 mph MIN. 4' CLEARANCE Risk Category 1I PER NEC 110.26(A) Exposure C Gust Factor ±0.18 "A"Dimension 5.1 ft Roof Pressure for Components and Cladding Zone 1 16.47 psf -25.65 psf Zone 2 16.47 psf -44.55 psf Zone 3 16.47 psf -66.15 psf DRIVEWAY 3' MIN. TYP TYP. RIDGE OBSTRUCTION �,._ 1//III ALL WORK SHALL COMPLY WITH PREVAILING CODES FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, AND THE CI•�'+ F HYRHILL3 DRAWING INDEX: ORDINANC9 S-1 COVER S-2 ARRAY LAYOUT & DETAILS S-3 ELECTRICAL TYP. EAVE MISSION SOLAR: S-4 NOTES MSE320SR8T (TYP) S-5 SPECIFICATIONS MODULE ROOF LAYOUT REVIEW DATE F S-6 SPECIFICATIONS EB S-7 SPECIFICATIONS NTS CITY pF ZEpHYRHI 02i S-8 SPECIFICATIONS PLAN EXAMINER `ewtu No PV MODULE QMR-UMC CLIP QMR 3/8"-16 X 3/4" HEX HEAD BOLT O' CROSSRAIL LIGHT 3/8" - 16 FLANGE NUT (Ti?) SUNMODO NANO SUNMODO NANO RAFTER MOUNT QMR RAFTER MOUNT (TYP) CROSSRAIL LIGHT (TYP) TOP VIEW EXISTING UNDERLAYMENT NTS EXISTING ROOF TRUSS 1/2" PLYWOOD 5/16" DIA SS LAG SCREW 2-1/2" EMBED MIN. TYPICAL SHINGLE ROOF ATTACHMENT NTS SUNMODO NANO RAFTER MOUNT 48 MAX. O.C. QMR-UMC CLIP (NP) (TYP) QMR-UEC CLIP (TYP) LI Li Li LI (I) Ln w � QMR-UEC MISSION SOLAR: MISSION SOLAR: (TYP) MSE320SR8T QMR-UMC CLIP MSE320SR8T Q� U (TYP) (TYP) (Ti?) ¢ w co w Li QMR-UMC CLIP QMR-RL14 (TYP) QMR-UEC CLIP SUNMODO NANO RAFTER MOUNT (TP) TYPICAL LAYOUT (TYP) (TYP) NTS ' A #10 THWN-2 (3 CONDUCTOR) NOTE: 3/4" EMT, FMC, FOR EXTERIOR ALL INVERTERS ARE EQUIPPED APPLICATION USE PVC OR W/ INTERNAL RAPID SHUTDOWN LFMC/LFNMC CONDUIT #10 THWN-2 (3 CONDUCTOR) SYSTEM PER NEC 690.12 3/4" EMT, FMC, FOR EXTERIOR LOCKABLE FUSED APPLCATION USE PVC OR PV AC DISCONNECT LFMC/LFNMC CONDUIT ENPHASE Q CABLE MISSION SOLAR: MSE320SR8T 30A 240V 2-POLE #10 THWN-2 (3 CONDUCTOR) ENPHASE Q CABLE Q-12-10-240 W/ ENPHASE IQ7-60-2-US 30A RK-1 FUSE 3/4" EMT, FMC, FOR EXTERIOR Q-12-10-240 (TYP) INVERTER APPLCATION USE PVC (TYP) OR LFMC CONDUIT N L2 L1 METER AC AC O L1 L1 DC DC L2 L2 NO. 1 NO. 11 N N SPACE 2D 20 MR-RL14 (TYP) SPACE q� 2D dJ 20 G NO. 1 NO. 11 NOTE: L#6 THWN 2 ALL STRINGS TO HAVE G AC AC TERMINATORS & SEALING CAPS DC DC INSTALLED PER MANUFACTURER'S 30 SOLADECK COMBINER BOX SPECIFICATIONS NEUTRAL GROUND 600V/ NON-FUSED OR SOLTECTION RESIDENTIAL TRANSITION BOX ENPHASE Q CABLE MISSION SOLAR: MSE320SR8T GEC BOND AT Q-12-10-240 W/ ENPHASE IQ7-60-2-US ENPHASE IQ COMBINER PLUS RACKING SYSTEM (TYP) INVERTER W/ (2) 20 AMP BREAKER (SEE NOTE #2) NEUTRAL GROUND AC PANEL 200 AMP/240V C/No NOTES: 1. 1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT MODULE SPECIFICATION INVERTER SPECIFICATION SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND MODULE MAKE MISSION SOLAR INVERTER MAKE ENPHASE STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION, MODULE MODEL MSE320SR8T INVERTER MODEL IQ7-60-2-US 2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43. 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(0). FSEC CERTIFICATION MAX AC POWER OUTPUT 250 VA 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS PMAX (STC) 320 W MAX. INPUT VOLTAGE 48 V RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE VOC (STC) 40.80 V NOM. DC VOLTAGE @ 240V 240 V ITEMS IDENTIFIED IN NOTE 1. VMPP (STC) 34.22 V NOM. AC VOLTAGE 16-48 V 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING NTINUOUS OUTPUT CURRENT 1.00 A MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING-ELECTRIC SHOCK HAZARD - DO MAX.. ISC (STC) 10.03 A NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN IMPP (STC) 9.35 A MAX. DC CURRENT 15.0 A POSITION OR EQUIVALENT. NOCT 46 C MAX. DC POWER (STC) 350 W 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON TC ISC 0.039 %/" CEC EFFICIENCY 97 % THE PREMISES AT SERVICE ENTRANCE. TC VOC -0.280 %/C 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. TC PMPP -0.377 %/C 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION. OPERATING TEMP. -40-+85 C 9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS. AN I NEC 310.15 (B)(2) SAFETY LABELS AND MARKINGS GENERAL NOTES: N EMERGENCY Co I VTACi 10.ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE NEC. 1 EQUIPMENT E LABELS FOUND HEREIN SHALL BE APPLIED SUCH INVERTERS MODULES HAVE SUCH U S S O BAR 12.PV ARRAY INTERCONNECTION TO BE MADE WITH BACK-FEED BREAKER. PRE-APPLIED 13.GFI BUILT IN TO ALL INVERTERS. EQUIPMENT FOR M 2. LABELS AND MARKINGS SHALL BE APPLIED TO COMPONENTS IN 1 -813-434--0284 ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. 3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV RESISTANT OUTDOOR-RATED LAMINATED VINYL IN ACCORDANCE WITH ANSI Z535.4-2011. SAFETY LABELS AND MARKINGS LEGEND A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT POCC. MAIN_SERVICE DISCONNECT MARKING CAUTION SOLAR PHOTOVOLTAIC SYSTEM A A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE ® -WARNING- DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT THIS SERVICE IS SUPPLIED BY MULTIPLE -WARNING- ELECTRIC SHOCK HAZARD.THE DC SOURCES. SEE DISCONNECTS BELOW. AUTHORIZED PERSONNEL ONLY CONDUCTORS OF THIS PHOTOVOLTAIC CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH SYSTEM ARE UNGROUNDED AND WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A w Ac DEMEcr RATED AC CURRENT: Y7,5A MAY BE ENERGIZED NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." NOMINAL AC VOLTAGE: 240V AUTHORIZED PERSONNEL ONLY THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER LOCATION: MAIN PV PANEL LOCATION: DISCONNECTS, (ENCLOSES JUNCTION BOXES, OTHER ENCLOSES RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. HOLDING DC CONDUCTORS CIRCUIT DISCONNECTING MEANS MARKING A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT PHOTOVOLTAIC DISCONNECT BREAKER CONTROLLING THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM ELECTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. A A THE LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL LETTERS AT -WARNING- LEAST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: ELECTRIC SHOCK HAZARD PHOTOVOLTAIC SYSTEM EQUIPPED "PHOTOVOLTAIC DISCONNECT." THE LABEL SHALL BE CONSTRUCTED OF DO NOT TOUCH TERMINALS. TERMINALS W� RAPID SYSTEM SHUTDOWN ON PJARRAY BOTH THE UNE AND LOAD SIDES MAY BE DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL. ENERGIZED IN THE OPEN POSITION. LOCATION:AC DISCONNECT(S) ' e11ki N o1 L � P PERC 60 CLASS LEADING 315325W e,. �'• —`. ;_ a Enphase IQ 7 and IQ 7+ Microinverters ors Electrical Parameters at Standard Test Conditions(STC) INPUT DATA(OC) 107-60-2-US IQ7PLU8-72-2-US Module Type MS£3155t28T MBE32OSRST MSE32SSRST IEC Commonly utad module p.IrIng;' 235 W-350 W+ 225W•446 at+ Power Output Pmax Wp 315 320 325 61215-61730-61701-Salt mist Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Mod r Efficiency1 R,63 18.94 19.24 UL Peak power tracking voltage 27V-37V 27V-45V Tolerance 0'+3% 0"+3% 0"+3% UL 1703 listed operating range 16V-48V 16 V-60 V Shost-Clrcult Current l_ A 9.957 10,026 10.060 .. ...................................._................._._................................... ......... Min/Max start voltage 22 V(48 V 22 V/60 V Open Circuit Voltage Voc V 40.44 40.80 41.14 c® CEC Max DC short r.rrcitit current(modufa lse) 1y4 15 A RatedCurrennt Iwo A 9 2`3 9.351 9:387 USIal.._ Dvervolta a 9class DC p ort II II Rated Voltage Vmp V 34.04 34.22 34.62 DC port backfeed current (IA CIA PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; Fuse Ratbtg 20 .C 20 AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter iQ 7+Microinverter Peak output power 250 VA 295 VA MSE320SRST:3201NP,60 CELL SOLAR MODULE Maximum continuous output power 240 VA 290 VA Womtal Operating Coll Temperature(NOCT-i 45.D9C(12'+=:1 CURRENT-VOLTAGE CURVE Nominal(L-l.)soitagelren9a° 240V/ 208V/ 240 Vi 208 V t 211..2641/ €83.229 V 211264V 183 229 V Temperature Coefficient of Pmax -0.377%t°C 12 :.- - --- ...... -. .---- Maxfmumcontinuousoutputcurrent 1.0A 1.1sA 1.21 A 1.39A Temperature coelf nt of Voc -0.280%/ 0 censlemc-25 c Nominal frequency 60 Hz 60 Hz Temperature Coefficient of Ise 0.039%t°C 15 ;- tncden lrrd._leosyl/n3.. — ...._....... Extended frequency range 47-68 Hz 47-68 Hz ......... ,... - . ....... ....... AC churl circuit Tara currem Duet 3 cycles 58 Arms 5.8 Arms e� Incident .irrd: eeo.:µr/ma Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(240 VAC) 13(208 VAC) 11(208 VAC) ingidcnt .;lad,=..wp m1m,. ...... Maximum System Voltage t,Ototivdc t'j s Oveervoltage<.1ass AC port 1#I III Operating Temperature Range -40°C(-40°F)to+85°C(185'F) 6 =40e W/m3. AC part backfeed current 0 A 0 A Power factor setting 1 Cl 1 C ntfetyC 8sFcation11n9 Type ncident o-d.=Zoo W/m2 Power factor(adjustable 0.7leadin 0.71a in 0.7leadin 0.7la m 1 } 9... 99 9 9... 99 9 Fire Safety Classification Typ 1,Class C 2 tt EFFICIENCY @240 V @208 V @240 V @208 V Front&Back Load(kit standard) 5631 Pa(111( per) ° 'k` Peak CEC efftr,:.ncy ti'7.h' 97.6 a 97.5".. 673% Tested to UL1703 standard ° f9 , to CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% Hail Safety Impact Velocity 25mm at 23 m/s Voltage M MECHANICAL DATA IQ 7 Microinverter Current-voltage characteristics with dependence on irradiance ------------ and module temperature Ambient temperature range -49°C to-66"C m i Relative humidity range 4410100%(condensing) Solar Cabs P type mono-crystalline Silicon (156.75mm) Connector type MC4(or Amphenai H4 UTX w`th additional 6-DCC-S adapter) Cell Orientation till cells(6x10),5 busbar BASIC DESIGN(UNITS:mm) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weigh: 1L08 kg(2.38 ibs) 1676mm x I008mm x 40mm Doe Module Dimension '- `-'� {65.98 .x1.'58in.} Cooling Natural convection-No fans in x9€1.68in Weight 20 kg(441b) ,s $s ApprfwW for wet locations Yes Pollution degree PD3 Front Glass 3.2mm(0.126 in.)tempered, Imwiron,anti-reflective coating111111111 1111111ff Fll1ll r o Enclosure Class 11 double insulated,corrosion resistant polymeric enclosure . Environmental category/UV exposure rating NEMA Type 6/outdoor Frame Anodized aluminum alloy ' 'm FEATURES Encepaulant Ethylene vinyl acetate(EVA) „°n° Communication Pourer Line Communication(PLC) ��— J-Box Protection class IP67 with 3 bypass-diodes am Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Cables PV wire,tm(39.37 in.),4rf /12 AWO „ aieig Disecnrlec?i>ng means The AC and DC connectors have been evaluated and approver;by ill-for use as thetoad-break Connector MC4 Compatible disconnect required by NEC 690. Compliance CA Rule 21(UL 1741-SA) UL 62109-1,UL1741/iEEE1547,FCC Part 15 Class B, ICES-0003 Class B, i" a s- CAN/CSA-C22.2NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and GontatnerFT Paflets Panels 320 W NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 53' Double stack 36 936 299.52 kW Front View Back View 1.No enforced DC/AC ratio.See the compatibility calculator ai ht1Rs,Lleupll .00nrLsn:u5 suggox.t.mm il _cumttAlikility 40' Double stack 28 728 232.96 kW 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. Panels Weight Height Width Length x Pallet _. ; To learn more about Enphase offerings,visit enphase.com EN PHASE 26 1,19$Ibs 42.45" A5.50' 67.00" P MI551©N SOLAR 2018 En^h^:i Energy.All riyh;c reso-ved.Alf traderrarks or bends u3ed arc the p:opr:ty o,E^phosra Energy,Inc ENERGY 21113-it2-rI Minion Solar Energy reserves the right to make specification changes without notice Mission Solar Energy 18303 s.New Braunfels Ave.,San Anionic,Texaolas 78235 000WENT Al, 2 th'r".,eO:A N-7Jie4oN K 422:iEvYe,DN nh r:s.23:..^.2C - intor�missionsolaccom i www.missionsccom Nc Enphase Q Cable Accessories Enphase IQ Combiner 3 MODEL NUMBER Q AGGREGATOR SPECIFICATIONS IQ Cntrdtfner 3 IC Combs tar 3 with Enphase 10 Envoy"primed circuit board for integrated revenue grade PV —� --— X l0 At�t 240-3 production trteterlrit (ANNSI C12,20+/0 5%)and optic al*Consumpilsan Monitoring(+1-2.5%). Aggregator Q-EA-3-tP-6ft(stngh.-phase).Comt tesuptothreernicerinverlert�rancf#esintoonehomerun. ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Protect with maximum 60 A,2•pole 0.CPD. Q Commercial Aggregator Q-BA-3-3P-35(three-phase).Combines up to three,single-phase microinverter branches into a three- Enphase idobiie Connect'° phase home run.Protect with maximum 40 A,3-pole OCPD, CEL LMODFM 03(4(I/12-year data plan) Plug and play industrial grade cellular modern with data plan for systems up to 60 CELLMODEM 01 3G/5 year data plan) iv icroinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, Dimensions 190 mm(W)x227 mm(0)x 80 min(H)17.5 in(W)x9 in(D)x 32 in(H)1 �; - CELLMODEM-Ml(4Gbased LTE-M/5-year dataptan) whereThere as adequate cellular service in the installation area.) Homerun conductor size range #12 to#4 AWG Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/1 2.5%). CT-200-SPLIT Enafo acre rating NERlA3.(up to 45"from horizontal) 'tcnxum°i cn mo itoring is revu,�d'or E u hz_e 5ar5e Systems Temperature range -40'Cio+55'C(-40'F to+122'F) Wire eec USB adapter Installed etthe IQ Envoy.For communications with Enphase Encharge'storage and Enphase COMM S-KIT 01 Enpewer"smart switch.includes USB cable for connection to IQ Envoy or Enphase i0 Combiner' Compliance UL1741(assembled produel)and UL6703(butkhe3d connectors) and allows redundant wireless communication with FJtr ttarge and Fnpower, CONDUCTOR SPECIFICATIONS Circuit Breakers Supports Eaton 88210,815,820,811230,811240,BR230,BR240,BR250,and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 Certitcation UL200S(raw cable),Ut 9703(cable assemblies),CG r:able BRK-15A-2.240 Circuit breaker,2 pole,15A,Eaton 811215 Flame test rating FT4 BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton 811220 Ei}I-;,•-01 Power fine carrier(communication bridge pair),quantity-one pair Gomptianc=_• i1oHS,OIL RES E GE,UV resistant,combined UL for the United States XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) Conductor type THHNITH W N•2 dry/wet Disconnecting mean$ The AC and D C bulileud Crime cturs have been evacuated and approve-d by UL for use as the load-break X A-L NV-PCCA-3 Replacement tG Envoy printed circuit board(PCB)for Comlrier 3 Aliscdnnectrequtred by NEC 69q ELECTRICAL SPECIFICATIONS Q CABLE TYPES/ORDERING OPTIONS —_._._.__ �_ •-__.______ �._. _ _�_a_m _ ._ Paring Continuous duty Model Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box System voltage 120/240 VAC,60 Hz Q12-1O-240 ?77 VAC 1 3m(4.2 ft) Portrait 248 F.ator+eR SCiCT bulbar rating 125 A Q-12 17-240 277 VAC 2.0 m(6.5 ft). Landscape(60-cell) 240 Max.continuous current rating(output to grid) 65 A Q-11-20-200 277 VAC 2.3 n1(7.5 ft) Landscape(72 cell) 200 Mar.fuse/circuit rating(output) 9u A ENPHASE Q;CABLE ACCESSORIES Branch circuits(solar and/or storage) Up to tour 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Name Model Number Description- - Max.continuous cacrrenl rating(input from PV) 64 A Raw(i Cable Q-12-RAW-200 300 meters of 12 AWG table with no connecter:. Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included Field-wireable connector(male) Q-CONN-10M Make connections from any Q Aggregator open connector Production Metering CT 200 A solid co.e pre-installed and wired to IQ Envoy Field-wireable connector(female) Q-CONN-1OF Make connections from any 0 Cable open eonnecrar MECHANICAL DATA Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Oirriensiofss(WxHxOj 49s x 975 x 16.8 cm(19.5"'x t f-75"s663) Height is 21.06 (5,15 cm wish mounting brackets). Disromlecttvol Q DISC 10 Disconneottool for Q Cable connectors,DC connectors,and AC module mount Weight 7$kg(16,5 lee) Q Aggregator sealing caps(male) Q-BA-CAP-10 Seating cap for unused aggregator connections Ambient tcmprrature range •40°C to+46°C(-40°to 115°i-) Q Cable sealing caps(female) Q•5FAL•10 One needed to wear each unused connector on the cabling Cooling Natural convection,plus heat shield Terminator Q'TERM-10 Terminator cap for unused cable ends Enclosure environmental rating Outdoor,NRTL-certified,NEMAtype 3R,polycarbonate construction Replacement DC Adaptor(MC-s) Q-DCC-2 j DC adaptor to MC4(max voltage 100 VDC) I Wire size, • 20 A to S0 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input:4 to 1/0 AWG copper conductors Replacement DC Adaptor(UT k; Q-DCC-5 ❑C adaptor to UTX(•,sax voltage 100:VDC) Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. TERMINATOR SEALING CAPS Altitude To 2000 meters(6,560 feet) Terminatords slnapcar often cable a caps INTERNET CONNECTION OPTIONS ends,sold in packs often and cable connections ." ---..- M ___ �.._ .,_ _ --__ __ (0-TERM-10) (Q-BA-CAP-10 and Q-SEAL-10) Integrated Wi-F3 802,11b/g,n Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) Ce.-ilar optirrnsi,CEl I MODEM-01(30)or CEt LMODEM-03(4G)or CELLMODFM-M1(4G based LSE-M) IIIDISCONNECT TOOL CABLE CLIP that included) Plan to use at least one per Used to fasten cablingtothe racking COMPLIANCE installation,sold in packs of ten or to secure looped cabling,sold in Ccrmpile'ncc,Combiner "� UL 1741,GAN!'L'SA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 (Q-DISC-10) packs of ten(Q-CLIP-100) Production metering'ANSI C12 20 accuracy crass 0 S(PV production) Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No,61010-1 To learn more about Enphase offerings,visit enphase.com To learn more about Enphase offerings,visit enphase.com /"� 82016 Enphase Energy.All rigs reserved,lived.Enphase,the Enphase lays,IQ Combiner 3,and other trademarks or son ice varies are the 1;2015 Enphase Energy.All ri,i,ts reserved.All trademarks or brands used entire property of Enphase Energy.Inc. """^"' EN P H AS E. hademarks of Errph.me Energy,Inc. ENPHASE, 20'rot t{?w 2018 C�1-'J3 '`.�Of No r "� • SUNMD1 __ SA 5 levels of protection against Aesthetically pleasing • unibody aluminum cast water penetration construction FASTEST I 360-degree positioning, serrated surface on both sides for rail mounting • • a Versatile mounting option includes direct-to-decking for fast installation • • • • - Integrated Ultra Soft Weather Resistant silicone gasket Alignment markers if s s s ■ s s The NanoMount Advantage enable easy installation - - ,/` The fastest roof attachment in �► • - solar / Versatile mounting options - - ' ' including direct-to-decking . „ / Eliminates the need to lift shingles and prevents damage to rApplicatian Composite shingle and rolled asphalt shingle I Material High grade aluminum, 304 stainless steel hardware High-Velocity Hurricane Zone Finish Black powder coating i. - Approved - Passed TAS 100 (a) Roof Attachment Rafter and decking Wind-Driven Rain Test Structural integrity IBC and IRC Compliant * ./ All materials are compatible with p Warranty 25 years • roof shingles SunModo, Corp. Vancouver, WA., USA , www.sunmodo.com • 360.844.0048 • info@sunmodo.com *� Nq Structu ral quick Mount PV ENGI UITV. $P CT THECtCtF Ingenuity in Engineefing Rail Spans for Quick Mount PV QRail Light System Mean Roof Height: 0<h≤15 ft Panel Orientation: Portrait Table 3 Roof Angle: 7<0 ≤27 degrees Exposure Category: C Roof Ground Wind Speed(mph) Wind Snow Zone Load 100 110 115 120 130 140 150 160 170 175 180 190 0 81 81 81 81 81 76 71 66 62 60 59 55 10 76 75 74. 73 71 69 67 66 62 60 59 55 20 61 61 61 51 60 59 58 56 55. 55 54 53 30 52 52 52 52 52 52 51 50 50 49 49 48 Zone 40 45 45 45 45 45 45 45 45 45 45 45 44 1 50 41 41 41 41 41 41 41 41 41 41 41 41 60 38 38 38 38 38 38 38 38 38 38 38 38 70 35 35 35 35 35 35 35 35 35 35 35 35 80 33 33 33 33 33 33 33 33 33 33 33 33 90 31 31 31 31 31 31 31 31 31 31 31 31 0 78 70 67 64 59 55 51 48 45 43 42 40 10 76 70 67 64 59 55 51 48 45 43 42 40 20 61 61 61 61 59 55 51 48 45 43 42 40 30 52 52 52 52 52 52 51 48 45 43 42 40 Zone 40 45 45 45 45 45 45 45 45 45 43 42 40 2 50 41 41 41 41 41 41 41 41 41 41 41 40 60 38 38 38 38 38 38 38 38 38 38 38 38 70 35 35 35 35 35 35 35 35 35 35 35 35 80 33 33 33 33 33 33 33 33 33 33 33 33 90 31 31 31 31 31 31 31 31 31 31 31 31 0 62 56 54 52 48 44 41 38 36 35 34 32 10 62 56 54 52 48 44 41 38 36 35 34 32 20 61 56 5452 48 44 41 38 36 35 34 32 30 52 52 52 52 48 44 41 38 36 35 34 32 Zone 40 45 45 45 45 45 44 41 38 36 35 34 32 3 50 41 41 41 41 41 41 41 38 36 35 34 32 60 38 38 38 38 38 38 38 38 36 35 34 32 70 35 35 35 35 35 35 35 35 35 35 34 32 80 33 33 33 33 33 33 33 33 33 33 33 32 90 31 31 31 31 31 31 31 31 31 31 31 31 Notes: 1. Tables are based on critical rail span for load combinations as specified in chapter 2 of the ASCE 7-10 and allowable design loads per the 2015 Aluminum Design Manual. 2. Panels are assumed to be in portrait orientation with a maximum length of 67.5" 959 Larchmont Court,Aurora,IL 60504 3/4/2019 630-219-1997(P) www.structuralenginuityinc.com C3