HomeMy WebLinkAbout21-1509 City of Zephyrhills PERMIT NUMBER
5335 Eighth Street
Zephyrhills, FL 33542 BAR-001509-2021
Phone: (813)780-0020
Fax: (813)780-0021 Issue Date: 03/09/2021
Permit Type: Add/Alter (Residential)
Property Number Street Address
02 26 210010 06000 0070 38493 County Road 54
Owner Information Permit Information Contractor Information
Name: CHIPPY HOLDINGS LLC Permit Type:Add/Alter(Residential) Contractor: JOPPA FACILITIES
Class of Work:Add/Alter Residential SERVICES LLC
Address: Pmb 170 35246 Us Hwy 19 N Building Valuation:$12,000.00
PALM HARBOR,FL 34684-1931 Electrical Valuation:$0.00
Phone: (813)928-1111 Mechanical Valuation:$0.00
Plumbing Valuation:$0.00
Total Valuation:$12,000.00
Total Fees:$150.00
Amount Paid:$150.00
Date Paid:3/9/2021 4:08:55PM
1ProjectDescription-
REPAIR VEHICULAR DAMAGE WINDOW MALLS&ROOF
jApplication Fees
Building Plan Review Fee $50.00 Building Permit Fee $100.00
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county,and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
APA.P
CONTRAC36R SIGNATURE PE IT OFFICEU
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
a���sauozo City of Zephyrhills Permit Appl(callvn Fax-813a80-021
Bvadtng Daportmam
Dote Received Z Plharm Contact tar Parmittlr7
OwAoesName uJ r Ownall'b"a'N9u�mmbber"p �(!� '���^fill
OrmrrrsAdd7a�s 35+� 7A4 d o�vraho"Illar (�
Foe Simple TWahotdar Hamo Owner Phone Number
h
Poo S1mplo TItlahotdar Address Al
JOB ADDRESS Chi. 1 fJ � -35 J LOT
SUBDIVISION PARCEL itAN Q "�(V - l 4 f p 0 6>Q a d'00!
JOSTArnEO FROM MPOW TAXbrOT7CE)
WORK PROPOSED � NSWCCNSrRO ADDIALT SIGN DEMOLISH
INSTALL ri REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
DESCRtMNOFWORK 4✓� 'J"0 'Z;>AVvtA t A-4465
BUILDING SIZE .�W FOOTAGE I.�-:3,C HEIGHT [7�=
VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL Is AW SERVICE PROGRESS ENERGY W.R.C.C.
[7PLUMSJNG Is ,AID
=MECHANICAL S /�, 'JALUATION OF MECHANICAL INSTALLATION
=GAS Q 1 ROOFING ED SPECIALTY= OTHER
FINISHED FLOOR(ELEVATIONS FLOM ZONE AREA MYES NO
BUILDER COMPANY �X4r05 S12d.-0t I,GGC.
SMRATURE REOSSTEAED Y I N . FEE CtrRr#3 Y r N
Addrocs 3�S 0/ 1QG ,BABSprvA Uatursmk CSC:tuo ury D
ELECTRICIAN COMPANY
SIGNATURE, 'Y N FL�CVFSREa Y Ai
Address Lfcansafl F_
PLUMBER Nj C014PANY
SIGNATURE `� REGW tETtcA YIN r'EE aU,4Rtil,
Add.. 1.1-vsnso
MECHANICAL =IVA, COMPANY
SIGNATURE REG ST-D Yr N , MCUnFmh Llai
Address License N
OTHER / COIItPANY
SIGNATURE •" Rt riFST17IED Y r N FEE CS Z4 Y I N
Addrosa LIWISa A
11IdT118111iIl9llillitillilll9171lifiill! ) illi9AiilII/ 9ili! lI9II )II
RESIDENTIAL Attach(2)Pot Plans:(2)e013 orBlAiding Plans:(1)sot at Energy Forms:R-O-W Permit for now construrAon,
;dntmum ten(ID)wemking days altar submiltb data RMdred aorta,Conutrmbon ftM,Stommala Ptens W1 SRt Fcm;q irMtaflr4,
Sanitary Facilities R T dumpstar,Site'Ara*Permit for subdMstons&:rIta projoets
COMMERCIAL Attacth(2)completo sets of BWfdiaq Piers plus auto Sooty Page:(1)set of Energy Foim,.RA-W Permit for now construcSon.
Nr4mum ton fig)wotldttg days aft submittaT data.Rog0W onstte,Cons:nrc6an Plane,Stormwater Plans Wl SRI Fen=grstatfed.
Statw FaaTites B t tiumpster.SRO work Pamlt(or an new projects.AE=nmt requirements must meal rmnpiLmoe
SIGN PENO Attmh(2)sets ar,Englneerod PUm.
-PROPERTY SURVEY ragWrod farall NEW con hmtlan.
Diroctlons:
FRI out sppU=Wn completely.
Owner a Contractor sign bark of application.notartzed
lfovw=500,alloticoofComimr,temomtsmqutrod. (AiCupgmdas over$7600)
" Agent(for the contractw)or Power ofAttomoy(ror the owner)vsnWdbesomeang vAthnotai Wletterfromc%=auahortngssmo
OVER THE COUNTER PERMITTING (copy at%;=bvrR regwml)
Rkanarp it zwlnt�pc Sevv= ScMeo Upgndoa A10 Fonces(PIaUSurvoytFaotagej :;.
Drlvoways-Not over Coanterit on pub0amodways-needs ROW f
h ;
NOTICE OF OEED•R MICTIONS:The undersigned understands that thlspermit maybe subject to'deed'reswc*#s'
maybewifth than County regutallow The umdersfwW assumes responsWty for compbanoe mM any
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSHMAM. If the owner has hired a contractor or
contactors to trdartadce worts,they may be required to be licensed In accordance with state and local regulatlom if the
contractor Is not ilcaned as required by law.troth the owner and contractor may be efted for a misdemeanor viclWM
under state law. It the owner or Intended contractor are uncertain as to what Ihensft requirements may apply for the
Intended work they are advised to cornet the Pasco County Building Inspection Section at 72M7-
SM, FuNtermore,if the owner has tared a contractor or contractors,he Is advised to have the r(s)sign
portions of the'cmatactor Block'of this application for which they wig be responsible. if yo%as the owner sign as the
oontractar,that may be an indication that he is not properly licensed and is not entitled to permitting prideges In Pasco
Cal mly-
TIMSIMIRTATtON IMPACT/Si'M1ES 11WACT AND RESOURCE RECOVERY FEES: The undersgned underulands
that Transportation Impact Fees and Rsamtcrse Recovery Foes may apply to the constroarm of now buildings,change of
-use in WNW buildings,or awtsion of e>dating bltgdlmgs,as speoifted In Pasco County Ordinance number MOT and
tl0.07,as amended. The undersigned also understands.that such fees.as may be due.will be identNed at the time of
penro t og. it Is,further understood that TimnsporMon impact Fees and Resource Recovery Fees must be paid pft to 3i
' s Io release,the paid t t hermit Firifter torep If retease. If the project does M Pam County aterlSewer Impact film power
Teas ire dim,they must be paid prlaf to pormItUsuencetnaecpordartce wrih a nllable Pasco Co"ordinances.
"CONSTRUCTION L.Ii:N i.AW(Chapter•713; 160da Statutes,as amendee tivAtation of work Is$ZM 00 or more,t
..:• idly that 1. on applicant, have been provided with a copy of the'Flotlda Consbuction Lien Law,--Homeownees
Protection Grime'prepay by the Rotlda Qeparbnent of Agriculture and Consumer Affairs. If the applicant Is sorneore
otheathan the'owner',i certify that Me%obtained a copy of the above described document and promise In good faith to t�
delhrer fttothe lowrneY prh�tosommenramrtent. :;
r CONiRACTMNOWNMAFIMAVi3: t cerBly total d the iMomtation in this application Is accurate and Well work
WE be done In compliance withall applicable taws regulating constructlon,zoning and led development. Application is
f. hereby made to obtain a permit to do work and iron as indicated. 1 certify chat no work or installation has
r" comma carl prior twis+wmce.of a permS:ard that ail worts will be performed to meet'standards of all taws regulating
consbuctlom County and Gllyy.code%zoning regtdaRta»,and land development regulations In the jurtsdicti mm, t also
oett*ltmnt I understand that the reVAGons of nther.gwerrpnorttagancies may apply to the Intended work,and that It Is
my rebEllyto idenIffy what actions 1 must take to be In compliance. Such agencies dude but are not ihrnitad to:
Degarinent of.EnvIronmental Prolectlon•Cypreas Bayheads,Welland Areas and Environmentally Sensitive
Lands,Wator/Wast"plerTmalmed t.
Seuthwast Florida water Nbrnageanent Qistri"elis, Cypress Bayfieads, Weiland Areas, Altering
Watercourses.
Army Corps of t:ngirmaers-Seawalls,Docks.Havigabte Waterwrays.
- Department of Health &Rehabilitative Servloe8 tvtronmerdet Health unit Welts,Wastewater Treatment.
SeptioTanks.
US Environmental Protection Agancy Asbestas abatement
Federal Avtetiorm Rulhortly-�trm'ays.
1 understand that the following r+eokbons apply to the use of 0.
Use offM is not dlowed to Flood Zone"r unless expressly permntecL
0 the fig material 14 to be used In Flood Zone A. it Is understood that a drainage plan addressing a
'compensating volume will be submitted at tune of permitting which Is prepared by a professional ensinear
gcermsedby time SiateolFlorida.
• I the fill material Is to be used In Flood Zone'A'In,connection with a permitted building using stem wag
construction,i�thaM wig be used orayto ftlh the"area within the stem vra L �
N S mateft Is to are used in any area..1 cWy that use of such N will not adversely affect adjacent
m be died for vkbft
the conditiortaH theuse fflbuilding permit Issued unifet permit won,for lotsless than
am whtahare etsvatedtylHl,an engineered drairnage plan Is required.
l` N I am the AGENT FOR THE OWNER,i promise In good faith to Worm the owner of the permitting cormMons set forth In
this ad6davit prior to o+arimen ft construotion. I understand that a separate permit maybe inquired for electrical work,
plumbing,signs,wells,pools,aV comffttoni g,on,or other Installations not speoifitelly)iuded to the applicatlam A
permit Issued shag be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
set aside any proiftrta of the technical codes,nor stag issuance of a permit prevent tore OWIding Otflotel from thereafter
requiring a correction of errors In plans,construction or violaVons of any codes. Every permit Iscrted shall became invalid
unless the work mdbwb ed by such penal is commenced within in sic months of permit Issuarm,or If work authorized by
the permit is suspended ar abandoned fora period of abt ffl months after the time the work Is commenced. An ext"Won
may be requested,in w dtbQ,from the i uPAI g ORkW for a period not to e>oosad ninety(00)days and will demortstate
k istillable cause fdr the a dension. N work ceases for ninety(90)consecutive days,the job its considered abandoned.
WARNING TO OWNER: YOUR FALURE TO RECORD A NOTICE OF CON MFRCBUW MAY RESULT IN YOUR
PAYING TWICE FOR IMPROV4MENTSTO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
O 1 G YOUR FLt'>MA,NiM(F.8.117.03)
og�WMMQR'ARiINT.es�ti�.eC`e.l.r�
ygs
—WTw�Nat!
0roduax! WhomeRyy�iowritiieiaoi ---- ,t�
r�sr
-71
ran +ri'l. - --e�m/�.`�... ��gl�tr&�(�I•t�tdRtf�s
anameOrmuaaeYtrlrariHvaedaatam�ed tvameorwamryb�.F�asdvrammp�l
y etAtNiziiatFNxcmrmamimFzsmrunpar
ia� Notary Public,State of Florida .,sr" `ti LEVAH RENE CNUMMS
COMOssiorM GG 284504 :; Notary fublk-State of Florida
1 ! My Comm expires Des 16.2022 Commtssion r s A 2170 2,
T�,�.• t a ,.f My Comm.Expfreb Apt Z3,T022
• .+• " Bonded through N0orwI Notary Assn,
JOPPA FACILITIES SERVICES
Date: February 8,2021
Subject: LETTER OF AUTHORIZATION TO BOBTAIN A BUILDING PERMIT FOR THE REPAIR WORK BASED
ON THE REPORT FROM ADVANCED ENGINEERING CONSULTANTS LLC.
Report Date:January 21,2021
Project Address:38493 CR 54 ZEPHYRHILLS, FL.33542
To Whom it may concern:
I Michael R. Brown authorize Ronald L. Peeples to,on my behalf,obtain a building permit for the repair
work at the above specified address.
I certify that I am the holder of the CBC License 1263600 in the state of Florida and the owner/Managing
Partner of Joppa Facilities Services LLC.
Address: 1325 Thornburg Rd. Babson Park, FL. 33827
Phone: (770)294-4910
Fax:_(863)456-4191
Email:m.brown@ioppafacilities.com
Owner: Michael R.Brown
'}'k4 LEVANfu liENE CHI-Stated
ESS
Flo
Notaryfublk-Stateoiflorida
Commission I GG 210321
0f.. My Comm.Expires Apr 23,2022
Bonded through Naha w Notary Am.
Notary Public: Leyah Rene Childress:
CLIENT INFORMATION
Client: F and R Block Homes,Jose Sanchez
Project Address: 38493 County Road 54,Zephyrhills,FL 33542
Client Email: nune1987@yahoo.com
Limited Visual Structural Engineering
Report of Visual Review of Car Crash
j
s
� d
i
Job No: 21006
Inspection Date: January 21,2021
Report Date: January 28,2021
DVANCED ENGINEERING
CONSULTANTS LLC
Michael Koffman P.E. 67584
Engineering Certificate of Authorization: 28038
Website:www.advanced-engineers.com
Address: 2651 Narnia Way, Unit 102 Land 0 Lakes, FL 34638
Phone: 321-794-6465 Email: mhoffman@advanced-engineers.com
2651 Narnia Way, Unit 102, Land O Lakes,FL 34638
Advanced Engineering Consultants LLC,321-794-6465
Contents
Introduction:.........................................................................................................................................................3
Findings:................................................................................................................................................................3
Exterior:South Facing Front Wall.....................................................................................................................3
Exterior:Roofing Panels....................................................................................................................................5
Interior:Interior Non-Load Bearing Wall..........................................................................................................6
Interior:Ceiling.................................................................................................................................................8
Conclusionsand Recommendations:..................................................................................................................11
Exterior:South Facing Front Wall...................................................................................................................11
CMUWall........................................................................................................................................................11
Windowsand Doors........................................................................................................................................11
Exterior:Roofing Panels..................................................................................................................................11
Interior: Interior Non-Load Bearing Wall and Ceiling Plaster.........................................................................12
2651 Namia Way, Unit 102,Land O Lakes, FL 34638 Page 2 of 12
Advanced Engineering Consultants LLC,321-794-6465
Introduction:
On January 21, 2021 Advanced Engineering Consultants LLC met with the owner of the multi-
family complex at the above-referenced site to visually review reported building distress from a
car crash. The purpose of the engineering report it to evaluate the degree of structural concern and
provide recommendations for the repair of the damaged area.
Findings:
Exterior: South Facing Front Wall
Front Door Placement
INFILL WITH CMU Window Placement
Figure 1:South Facing Front Wall,Internal View
2651 Narnia Way, Unit 102,Land O Lakes, FL 34638 Page 3 of 12
Advanced Engineering Consultants LLC,321-794-6465
Rebuild wall below bond beam per section
detail.
Figure 2:South Facing Front Wall,External View
S i
THIS OPENING TO BYC^ 1
INFILLED WITH CMU
BLOCK AND REPLACED
Shear Vertical Crack from Car
WINDOW PER SECTION = Crash. MINOR DAMAGE
�,
DETAIL A = ALLOWED TO REMAIN.CMU
WALLTO BE INFILLED BENEITH
Figure 3:Shear Vertical Crack from Car Crash
2651 Narnia Way, Unit 102, Land O Lakes, FL 34638 Page 4 of 12
Advanced Engineering Consultants LLC,321-794-6465
Exterior: Roofing Panels
Possible loose screws from car crash.
See recommendations section of report.
Figure 4:Metal Roofing Panel Loose Screws
The inspection started on the south wall of the multi-family complex where the car crash
occurred. This collision damaged a 152"section in length and 82"of damage in height of the
concrete masonry unit(CMU)wall as per Figure 1 and Figure 2. T'here is a vertical crack in the
CMU block above the temporary opening (this opening to be infilled to restored to its original
condition with new CMU.. In addition,the impact caused the roofing panel screws to loosen
which could lead to water intrusion and cause water damage.
2651 Narnia Way,Unit 102,Land O Lakes, FL 34638 Page 5 of 12
Advanced Engineering Consultants LLC,321-794-6465
Interior: Interior Non-Load Bearing Wall
-.t
LL �
Figure 5:interior Wall Damage from Car Crash(East Looking View) SOUTH FACING
EXTERIOR WALL
2651 Narnia Way,Unit 102,Land O Lakes,FL 34638 Page 6 of 12
Advanced Engineering Consultants LLC,321-794-6465
yam,
Y
i
"0. I �r-• t.: t_. III _ .
4., ,. i 'd Collapsing Door Frame
, .o
q -
,.,•"mod r�. ,s,
Figure 6:Interior Wall Damage from Car Crash(East Facing)
1.
1 {
Figure 7:Damage due to shear from car impact to the Interior Wall Corner
2651 Narnia Way, Unit 102,Land O Lakes,FL 34638 Page 7 of 12
Advanced Engineering Consultants LLC,321-794-6465
Interior: Ceiling
Figure 8:Wall and Ceiling Destruction from Car Crash
As per Figure 5 and Figure 6,there has been significant damage to the interior non load bearing
wall within the apartment complex. As a result,this has caused the door frame, leading into the
bedroom,to start to collapse. In addition,there is cracking along the corner of the wall that can
be seen in figure 7. Also, parts of the ceiling have been damaged due to the upward force of the
sheet rock and wall studs pushing into the ceiling. The wall is in-between the two trusses above.
No damage was observed to the trusses. After demolition contractor shall verify that no damage
has taken place to the trusses. Contact Advanced Engineering,to speak with Engineer of record
for any new findings.
2651 Narnia Way, Unit 102,Land O Lakes, FL 34638 Page 8 of 12
Advanced Engineering Consultants LLC,321-794-6465
Unit 38485 Unit 38487 Unit 38489 Unit 38491 Unit 38493
F
87
t -
N
Location of Internal wall damage
(non-load bearing) Kitchen
�5 BASM ! 25
Bedroom Living
8r
Location of Car Crash Damage
F. r
.,''�' _ _� � �`• P-�__ ;r--- - ate •
41
M € V
Figure 4—CONDITION PRIOR TO CRASH,FRONT ELEVATION FACES SOUTH
2651 Namia Way, Unit 102,Land O Lakes, FL 34638 Page 9 of 12
Advanced Engineering Consultants LLC,321-794-6465
EXISTING METAL ROOFING IN GOOD CONDITION.n10:C2-IN
GALVANIZED SELF-DRILLING ROOFING SCREWS TO BE
USED TOREPLACEALL SCREWS %TI1iIN 10'OF DAMAGE.
EXISTING TRUSSES OBSERVED
TO BE IN GOOD CONDITION EXISTING DAMAGED PLASTER CEILING TO BE
REPLACED.PER 2020 FBC-RESIDENTIAL7TH EDITION
SECTION R701 INTERIOR COVERS.MATCH EXISTING
THICKNESS AND FINAL FINISH
EX BOND BEAM IN GOOD CONDITION TO
REMAIN
c
1>0 P.T.GROUND AT ALL WINDOWS FOR
CURTAIN ATTACHMENT AND FASTENING TO
DRYWALL
#6 BARS DOWEL IN CMU CELLS TO EITHER SIDE
OF OPENING.&V4 6IMBEDDMENT INTO BOND
BEAM(SECURE WITH SIMPSON SET XP-EPDXY, t
DOWEL TO HAVE 251NCH OF OVERLAP WITH NEW
r'f VERTICAL STEEL(SAW CUTFACE SHELL OF =
NEW CMIU BLOCK TO INSERT#5 BAR AS z
NECESSARY.)GROUT VERTICAL CELLS
p CONTRACTOR TO SUPPLY FLORIDA PRODUCT m
p O
APPROVALS.CONTRACTOR SMALL INSTALL
NBY WINDOW IN ACCORDANCE TO FLORIDA c�
DAMAGED BLOCKS PRODUCT APPROVALS.
ui
SHALL BE REMOVED
AND REPLACED PRECAST SILL W1 1X3 BELOW
m
BLOCK PAINTED TO _ 112"DRYWALL ON 1X2 P.T.FURRING EVERY&O.C..
MATCH EXISTING FASTENED EVERY 6"O.C_ON EDGE&ffi'IN FIELD
R-5.7 INSULATION ON ALL EXTERIOR WALLS.
`S IA\V FORM R402-2017
�z
#5 VERT WALL REINFORCEMENT EVERY 4'MAX•
W13000PSI GROUT FILLED CELLS
WOOD OR VINYL BASE
EXISTING FOUNDATION IN GO D CONDITION
EX GRADE
EPDXY AND ANCHOR NOTE:
SIMPSON SET-XP EPDXY.95 REBAR MINIMJM 6"EMBEDOMIENT INTO FOUNDATION WITH
MINIMUM 25"EXTENSION ABOVE FOUNDATION FOR LAP SPLICE.INSTALL IN EPDXY
ACCORDANCE WITH MANUFACTURER INSTRUCTIONS.MAINTAIN MINIMUM EDGE
DISTANCE OF 2 112"FROM EDGE OF SLAB
2651 Namia Way, Unit 102,Land O Lakes,FL 34638 Page 10 of 12
Advanced Engineering Consultants LLC,321-794-6465
Conclusions and Recommendations:
Exterior: South Facing Front Wall
CMU Wall
1. The exterior south facing front wall should be repaired using#5 rebar dowelled into
existing foundation AND at bond beam with a minimum of 6"embedment with Simpson
SET-XP epoxy. Apply in accordance with manufacturer instructions.
2. It is our professional opinion that#5 vert. wall reinforcement is placed every 4'max, w/
3000 psi grout filled cells. There should be a 25"minimum lap splice with#5 vertical
rebar.
3. It is advised that the damaged blocks shall be removed and replaced, and block painted to
match existing.
4. We recommend that all exterior cracks should be sealed to prevent water entry. For
sealing it is recommended to use a whole surface sealant equivalent to Seal-Krete. If after
sealing should exterior cracks continue to develop to widths 1/8"or greater, contact this
Engineer or other professional for further review.
5. R-5.7 insulation should be used on all exterior walls, IAW form R402-2020
6. We recommend using a steel anchor that is epoxied into the foundation at 8"minimum.
Windows and Doors
7. It is our recommendation that lx6 p.t. header is used at all windows for curtain
attachment and fastening to drywall.
8. precast sill w/ 1 x3 below
9. We recommend that 1/2" drywall on lx2 p.t. furring every 6" o.c., fastened every 6" o.c.
on edge& 8" in field.
10. Contractor to supply Florida product approvals. contractor shall install new window and
door in accordance to Florida product approvals.
Exterior: Roofing Panels
1. Upon inspection,the existing metal roofing is in good condition,but we recommend that
#10 x 2-in galvanized self-drilling roofing screws to be used to replace all screws within
10' of damage.
a. Tough 16 mm EPDM washer should be used to help form a water-tight seal.
2651 Narnia Way, Unit 102,Land O Lakes,FL 34638 Page 11 of 12
Advanced Engineering Consultants LLC,321-794-6465
t i
Interior: Interior Non-Load Bearing Wall and Ceiling Plaster
1. The interior non-load bearing wall will be replacing existing non-load bearing wood
framed all with 2x4 16" o.c. with existing electrical to be reused.
2. Plaster per 2020 FBC-Residential 7t'Edition, Section R701 Interior covers.Match
existing thickness and finish
Respectfully submitted,
Digitally signed by
Michae I VV Michael W Hoffman
Date:2021 .01 .28
Hoffma.,'n' 7.47 _ , ,
.00 05 00
Michael W. Hoffman,State of Florida, Professional Engineer, License No. 67584
Advanced Engineering Consultants,LLC
This item has been digitally signed and sealed by Michael W.Hoffman on the date indicated here. Printed copies of
this document are not considered signed and sealed and the signature must be verified on the electronic copies.
Per rule 61G15-23.004(3)(d)(2.)(When a digitally created seal is not used and paragraph(e)"A digital signature
applied to an item in electronic form shall have the same force and effect as signing all of the individual sheets or
pages contained within that item unless otherwise limited as specified in subsection 61G15-30.003(3), F.A.C."
2651 Narnia Way, Unit 102, Land O Lakes, FL 34638 Page 12 of 12
Advanced Engineering Consultants LLC,321-794-6465