HomeMy WebLinkAbout21-1513 B
x
F�onlull City Of Zephyrhilis PERMIT NUMBER"-
- 5335 Eighth Street
Zephyrhills, FL 33542 BNR-001513-2021
Phone: (813) 780-0020
Fax: (813) 780-0021 Issue Date: 03/18/2021
Permit Type: Building New (Residential)
Property Number Street Address
04 26 21 0260 00000 0170 6825 Shelby Lynn Way
Owner Information Permit Information Contractor Information
Name: LINKS AT CALUSA SPRINGS LLC Permit Type:Building New(Residential) Contractor: K HOVNANIAN FLORIDA
Class of Work:SFR Construct OPERATIONS LLC
Address: 2301 Lucien Way 260 Building Valuation:$215,946.00
MAITLAND,FL 32751 Electrical Valuation:$6,300.00
Phone: Mechanical Valuation:$5,200.00
Plumbing Valuation:$5,900.00 ;
Total Valuation:$233,346.00 "
Total Fees:$15,307.14
Amount Paid:$15,307.14
Date Paid:3/18/2021 2:27:38PM J
Project Description
CONSTRUCT SINGLE FAMILY 3,280 SQ FT LAC
Application Fees
Mechanical Plan Review Fee $33.00 Building Permit Fee $1,109.73
Irrigation 3/4 Meter(Calc) $732.71 Plumbing Permit Fee $69.50
SIF 1 percent Fee $83.28 Sewer Connection Residential Fee $2,090.00
Public Safety Impact Fee-Admin $26.35 Water Connection Residential Fee $1,010.00
3/4 Water Meter Fee(Calc) $732.71 Building Plan Review Fee $554.86
Electrical Permit Fee $71.50 Driveway Fee $45.00
Electrical Plan Review Fee $35.75 Address Fee $30.00
School Impact Fee $8,328.00 Mechanical Permit Fee $66.00
Plumbing Plan Review Fee $34.75 Public Safety Impact Fee-Police $254.00
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
C CTO SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
• 1111
• ' IZEPHYRHILL
BILLING CONTACT
JAMES CLARK Stan
K HOVNANIAN FLORIDA OPERATIONS LLC
2301 LUCIEN WAY STE 260
MAITLAND, FL 32751
INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION
INV-00002848 03/16/2021 03/16/2021 Due NONE
REFERENCE NUMBER FEE NAME TOTAL
BNR-001513-2021 3/4 Water Meter Fee(Calc) $732.71
Address Fee $30.00
Building Permit Fee $1,109.73
Building Plan Review Fee $554.86
Driveway Fee $45.00
Electrical Permit Fee $71.50
Electrical Plan Review Fee $35.75
Irrigation 3/4 Meter(Calc) $732.71
Mechanical Permit Fee $66.00
Mechanical Plan Review Fee $33.00
Plumbing Permit Fee $69.50
Plumbing Plan Review Fee $34.75
Public Safety Impact Fee-Admin $26.35
Public Safety Impact Fee-Police $254.00
School Impact Fee $8,328.00
Sewer Connection Residential Fee $2,090.00
SIF 1 percent Fee $83.28
Water Connection Residential Fee $1,010.00
6825 Shelby Lynn Way Zephyrhills, FL 33542 SUBTOTAL $15,307.14
REMITTANCE INFORMATION TOTAL $15,307.14
City of Zephyrhills
5335 8th Street
Zephyrhills, FL 33542
March 16,2021 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1
•. . PASCO COUNTY, FLORIDA
Permit No.
Date Permitted
Builder Name/Owner Name Le� Control W
County Parcel No. D T I G U--G Rkh 0iY M6 d1 D SubDly:
�.r P�
Address/Location 6 2v1o_/
Lbv
Classiticatlon/Type of Us@
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 21 6 a
Exempt 1(es Q No How Determined
i
Impact Fee Amount Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ 2-6
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [j Yes..C1 No How Determined
PARKS AND RECREATION FEE-
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $
Exempt Yes No How Determined.
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt Yes E] No How Determined Total Amount
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AM04NTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY
AdWowtedgement balow does not Imply acoeptenoe of concurrence,but simply receipt of•a copy of this form,placing
the building permit owner.on notice of this assessment and tho condfilons of payment for same. /
DATE RECEIVED BY
RECEIPT NO. DATE BY
INSTR#2021026948 OR BK 10276 PG 1445 Page 1 of 1
02/09/2021 02:13 PM Rcpt:2259108 Rec:10.00 IDS:0.00 IT:0.00
Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller
Parcel ID Number:04-26-21 -0260-00000- 0
Prepared By Daphne Clark
and K Hovnanian Homes
Return To: 2301 Lucien Way,Suite 260
Maitland,FL 32751
NOTICE OF COMMENCEMENT.
State of Florida.
County of PASCO.
The undersigned hereby gives notice that improvements will be made to certain real property,and in accordance
with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement.
1. Description of property: LOT 17
Legal Description: LINKS AT CALUSA SPRINGS according to the plat thereof,as
recorded in Plat Book 81 Page 74-79 of the public records of Pasco
County,Florida.
Addresses 6 8 2 5 S h e l bsj L ^n W ay_Zephyrhills FL 33542
2. General description of improvements: New Single Family Home
3. Owner information: Name Links At Calusa Springs,LLC
Address 2301 Lucien Way,Suite 260,Maitland,FL 32751
4. Fee Simple Title Holder:N.A.
5. Contractor name and address: Name K.HOVNANIAN FLORIDA OPERATIONS,LLC
Address 2301 Lucien Way,Suite 260,Maitland,FL 32751
6. Surety:N.A.
7. Lender:N.A.
8. Persons within the State of Florida designated by the Owner upon whom notices or other documents may
be served as provides by 713.13(l)(a)7.,Florida Statutes: N.A.
9. In addition to himself,Owner designates the following to receive a copy of the Lienor's Notice as provided
in 713.13(1)(b),Florida Statutes. N.A.
10. Expiration date of notice of commencement:One year from the date of recording.
WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13,FLORIDA STATUTES,AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTENT TO OBTAIN FINANCING,CONSULT
YOUR LENDER OT ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
11.Date Signed: 2 9 2021 Signature of Owner's Agent: Q.�L4"
Ja es Makrak ky
Sworn to and subscribed before me this 2 9 26 2I.• by James Makransky who is personally known to mp.
• : pAPNNEA,C �q8
Notary Public ��rttsslot+�G2,0
Daphne A Clark +4•' * trea3uno W&O
My commission expires:6/27/2023
Serial No.GG 308696 otary Signature: aFp° Notary seal:
;,ao3G���. State Of Florida,County Of Pasco
This Is to certify that the foragoing Is a
true and correct copy of the document
m '•...bg on file or of public record in this office.
Tr $ Wit ss my hand an official seal this
day M
of Q 2
<t Nikki Alvar es,Esq.,Cl &Comptroller
Pasco Co n rida
gy , Deputy Clerk
CITY OF " " BUILDING
ZEPHYRHILLSNOTICE DEPARTMENT
OF ADDITION OR CORRECTION
D • NOT REMOVE
ADDRESS DATE PERMIT#
THIS JOB HAS NOT BEEN COMPLETED.The f0owind additions or correc ons shall be made before the job
will be accepted.
It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL
cover or cause to be covered,any part of the work with flooring,lath,earth
or other material,until the proper inspector has had ample time to approve 780-0020 FOR RE-INSPECTION
the installation.
OFFICE HOURS 8:00 AM-4:30 PM MON.-FRI. INSPECTOR
8IX780-0020 City of2ephyrhills Permit Applicati6h Fa"13-780-0021
Building DepaMnent
z
Date.Received L )I -Phone Contact for Permitting 407 257 -6940................
m LINKS AT CALUSA SPRINGS. L 407-257-6940
owners Name LC Owner Phone Number
'Owners Address 2301. Lucien Way Ste 260, Maitland FL 32751 Owner Phone Number
Fee-Simple Titleholder Name I N/A Owner Phone Humber
Fee Simple Titleholder Address N/A
joB ADDRESS (E 2 r In't
LJA� I IS, PL 3 3 2 LOT#
SUBDIVISION LINKS AT CALUSA SPRINGS PARCEL 10# 04-26-21-0260-0000OLd 71C)O
(00TAINED FROM PROPERTYTAXnariCE)
WORK PROPOSED =V
LnL I NEW coNsTR ADD/ALT SIGN 0 Q DEMOLISH
INSTALL REPAIR
PROPOSED USE 1XI SFR X COMM OTHER I
TYPE OF CONSTRUCTION BLOCK 0 FRAME Q STEEL Q _J
DESCRIPTION OF WORK' - I NEW SINGLE FAMILY HOME Total Sq Ft,'379-E)
TOTAL Under R, UvIng
Roof SQ FOOTAGE xQ;o(-" 'EIGHT
BUILDING SIZE ea( H
WiMis;
®BUILDING
VALUATION OF TOTAL CONSTRUCTION
®ELECTRICAL $ 6,300.00 AMP SERVICE 150 PROG§E S NERGY Q WA.E.C.
MPLUMBING _51900.00
®MECHANICAL $ 5,200.00 VALUATION OF MECHANICAL IN S-TAL$ON
1
,=GAS M ROOFING Q SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES ®.NO
HHHH".H HHH
ii tit i.4!,H!44t,91,
BUILDEIP COMPANY K HOVNANIAN FLORIDA OPERATIONS I LLC
44,
SIGNATURE REGISTERED I YIN FEE
_J + iICURRE
L___J
Address 2301 Lucien Way,Ste 260,,Malfiand FL 3276 License'#,'J CBC12MO47
ELECTRICIAN COMPANY R BERSTON ELECTRICAL,SERVICES, INC
SIGNATURE"' 'W REGISTERED I Y/.N FEE CURREN LYI_N
_J
Address 16812 SlIvO Shores Lane,Odessa.FL 33556 License# EC13002645
BAYONET PLUMBING, HEATING&AIR-COND.LLC
COMPANY
-SIGNATURE ja_"�L REGISTERED I Y/'N "PEE CURREN LILN J
Address P.O.Box 5308,Byonet Point,FI_34674 rCF C7042998
MECHANICAL COMPANY AIR FLOW DESIGNS, INC.
SIGNATURE REGISTERED Y/ N - I FEE CURREN
Address 250 Jasmine Rd.,Casselberry FL 32707 I-Idense# rGAC1814423
:OTHER ROOFER COMPANY HUGH MACDONALD/ALVAREZ ROOFING
.,SIGNATURE REGISTERED I Y/ N FEE CURREN LYLt N
F_
Address 10825 Tom Folsom Rd.,Thonotosassa,FL 33592 License# PCC1329562
.11 it H:1 N,f H 111 Hi+ !'I I I IIH I H I I 11 M 1111!-to 11, !,1 1
RESIDENTIAL Attach(9)Plot Plans:(2)sets of Building Plans;(1)set of Energy Forms;R-OwW Permit for new construction,
Minimum. n te (10)working-days after submittal,date. Requ�lred op9ite,Construction Plans,Stormwat6r Plans W/Silt Fence installed,
Sanitary Facilities&I dumpstei—,Site Work Permit for subdivisionsnarge projects
COMMERCIAL Attach(2)-complete sets of Building Plans plus a Ufe,Sqfqty Page;(1)set of Energy Forms.R-O-W Permit fornew construction.
Minimum,ten(16)working days after submittal date. Required onsite,Construction Plans,-Stormwitee Plans W/Silt Fence installed,
Sanitary Facilities&I dumps*.Site Work Permit for all.new projects.All commercial requirements must rneet.compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
""PROPERTY SURVEY required,for all NEW construction.
`Directions: "
............. -----------
Fillout application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Nciticd of Commandeindrit is required. (AfC upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Remois.if shingles sewers Service Upgrades A/C 'Fences(Plot[Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
D
Q
Singe Family Dwelling
Plan Review Comments
1. RRE shall be a'minimum of 8" above the road elevation and an engineered site plan.
2:- Lots shall be graded to comply with R401.3 of the.F.B.C:
I Compaction test required if 24"or more of fill_dirt is brought-in at any one.place:
4: Tie in survey required before pouring concrete.
5; Driveways require.a R,ON. use pennit: .All 4 sides Of driveway thru the sidewalk shall have
: . expansion material.
61 Alt setbacks shall be met.
All:prop erty:markets shall be uncovered.-arid in at time:of first inspection.
8:: All A:D.A.requirements shall be met:
9: No electric,.plumbing;mechanical, or.framing shall.be:covered without an inspection.and .
approval first:
10:All Garages shall comply with section R302:6 of the F.B.-C. (Fire Separation).: -
11. Appliances shall not be installed in a location where subjectao mechanical.damage unless
protected by approved barriers. M303:4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the RB:C:
13. Foundation supports for AX uriits.shall.be raised at leas_t 3" above finished_ grade_. M1308..1.
14. Return air in all bedrooms. F.B.C. M1620:4
15. Smoke detectors are to be installed in accordance with R313:1_of.the F.B.C_.
16:All glazing requirements are to be in accordance with R308.4 of the F.B.C:
17..All means.of egress are.to be m accordance'with R311 of the F.B.C:.
18: "Green_gypsum board" shall not be used as a baeker'in showers or tubs:R702:4.2 F.B.C.
19. Combination-type AFCI,breakers are required at all locations requiring an AM.type breaker.
. .
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be installed in accordance with the F B.C:
21. All plumbing, mechanical, and electrical shalfbe separate from unit to unit: This includes all
underground plumbing and electric.
22. All 2016 N.E.C. Codes will be enforced:
23. Tamper-Resistant Receptacles in accordance with 406.11 ofthe 2016 N.E:C
24. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
25: R403.5.3Hof water.'pipe insulation.
Insulation for hot water'pipe with'a minimum thermal resistance (R-value) of R-3 shall be applied to the
foliow- in g: ,
Piping 3j;inch (1.9:1 mm)and larger in nominal diameter.
Piping serving more than one dwelling'unit:
Piping located outside the conditioned space:
Piping prn the:water heater'to a distribution manifold:
Piping:located under a floor slab:
Buried in piping.
Supply and return piping in recirculation systems other than demand recirculation-systems:
25. Blower door-test shall be provided.before C,O:
26. A coov of the a ergy cacls shall be:with Dern:it at all times
27 Copy of fina[in sulation reyo it-shall be provided ivith yermit before finch
28. No fence,pool or screen enclosure :is issued with.this hermit'
F:F:E:-Finished Floor Elevation
F.B.C-:Florida Building Code 6t'Edition
R.O.W.-Right of Way
A.D.A.=:Americans with Disabilities:Act- N.E.C.-National Electric.Code (2016)
813-780-0020 City of Zephyrhills Permit Application Fax-81 3-180-0021
Building Department
Date d Receive
Phone Contact foiPermitting L407 257 -694P
...........
Owners Name LINKS AT CALUSA SPRINGS. LLQ _j Owner Phone Number 1 407-257-6940
Maitland F-L 32751 F Owner's Address 12301 Lucien Way, Ste 260, Owner.Phone.Number
Fee Simple Titleholder N.M.. owner Phone Number
Pee Simple Titleholder Address NIA
.JOB ADDRESS 'g 2-E; Sk9_1_b L nr% (JCL,i e P6-,r S,K 3:3 5�l LOT#
SUBDIVISION ,LINKS AT CALUSA SPRING PARCELID#=04-26-2 1-0269-00000. )
(OBTAINED FROM PROPERTY TAXNOTICE)
WORK PROPOSED NEW CONSTR ADDIAL-r SIGN DEMOLISH
INSTALL R REPAIR
PROPOSED:.USE SFR X Q COMM OTHER
TYPE OF CONSTRUCTION EX-1 BLOCK 0 FRAME STEEL
DESCRIPTION OF WORK JNEW SINGLE FAMILY HOME Total Sq F.
BUILDING SIZE =OTAL Under Roof SO FOOTAGE iv+ng HEIGHT I
BUILDING $ VALUATION OF TOTAL CONSTRUCTION
ZDELECTRICAL $ AMP SERVICE150 PROGRESS ENERGY 0 W.R.E.C.
ZIPLUMBING r5,900.00
]MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
r___jGAS ROOFING F-1 SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES X NO
BUILDER
COMPANY
SIGNATURE REGISTERED I Yj N j FEE:PVRREN Y/,W-j
Address. F_ u9prige'o
ELECTRICIAN COMPANY
SIGNATORk REGISTERED Y/ N FEE cuRREN LYLN
Address :License#'
RR x �n;___ _ Fe 1,,x -Se- A on f-L*,y4 sc4j�p: LL C.
COMPANY rs
SIGNATURE REGISTERED I Y/1.Nj__'—FEE CURRE.N LILN_j
Address io, GQ;K 119t4 , bover FL 3S522 License# Ft}6:00 4 r7 2 020
MECHANICAL COMPANY
SIGNATURE REGISTERED FEE CVRREN
Address License#.F
QTHERROOFER COMPANY
$IGNATURE REGISTERED I Y'/ N FEE CUR110% LILN_j
Address License# F_
fft+ 1 lirlill-I 11 11111 1 1 1 H I 111+1 2 11 11 1 1-11 t 1 1111111 11 1 1
RESIDENTIAL Attach t2)Plot Plans,-'(?)Opts-of Building Plans;(1)set of.Energy Forms;R.O-W Permit for new construction,
0)-w Minimum ten(1orking days after submittal date. Re,qu.ired:'Onsite,Construction Plans,Stormwater Plans wl Silt:Fence installed,
Sanitary.Facilities.&1 dumoster,,Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Oullding'Plans pluse Life-Sdfejy Page;(1)set Of Energy Forms R-O-W'Permitfor new construction.
9
Minimum.ten(10)Workingdays'after submittal date. Required onsite,Construction Plans,Stonhwater Plans w/Silt Fence installed;
Sanitary Facilities&:I dumpst4t.Site Work Permit for all new projects.All commercial requirements must meet compliance
-SIGN PERMIT Attach(2)sets of Engineered Plans.
""PROPERTY SURVEY required for all NEW construction;
Direcfionsr
Fill out application completely.
Owner&Contractor sip.-back of application,.notarized
If over$2500,allotlCre'of Commencement is required. (A/C upgrades over$7600)
Agent(for the contractor)-or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy'of contract required)
Reroofs if shingles Vewers Service Upgrades A/C Fences(Flot(Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The'undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work,they may be required to be.licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may cited for a misdemeanor violation
under state law: If the owner or intended contractor are uncertain as to what.licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division=Licensing Section at 727-847-
8009.. Furthermore, if the owner'has hired a contractor or contractors, he is advised to have the contractor(s) sign
Portions of the "contractor.Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES-IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the.construction of new buildings, change of
use'in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood.that.Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or-final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be.paid prior to permit issuance in accordance with applicable Pasco County ordinances:
CONSTRUCTION.LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is,$2,50.0.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner",- I certify.that I have obtain ed-acopy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement...
CONTRACTOR'S'!OWNER'S-:AFFIDAVIT: 1-certify.that all.the..information in this application is accurate and that all work
Will be done in compliance with all applicable:laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work=and" installation as indicated. I'certify that no work.or installation has
commenced prior to issuance of a permit and;that,all work will be performed to meet standards of all laws regulating
construction;-County:and City-codes", zoning regulations; and land'development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
Southwest Florida Water Management District Weils, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls,Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to-the use of fill:
Use of fill is not allowed in Flood Zone W"unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used•in Flood Zone"A" in connection with a permitted building using stem wall
construction;I-certifythat.fill will be used only to fill the area within the stem wall.
If fill material is to bei used in any area, I certify that use of,such fill will not adversely affect adjacent
properties. -If use of.fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one(1)
acre which,,aro;dlevated.by fill,an engineered drainage plan is required.
'if I am..the:AGENT,FOR-THE^;OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidav,.it:prior tb connttnencing.construction. I understand that a separate permit may be required for electrical work,
plumbing;aligns,"-ilveifsr';pools -air conditioning, gas, 'or other installations not specifically included in the,application. A
permit issued shall`be:construed to be a license to proceed with the•work and not as.authority to violate, cancel, alter,or
set aside'any:provisions pf:the=.technical codes, nor shall issuance of.a permit prevent the Building Official from thereafter
requiring4correcti.h of e"rrors°in-plans,construction or violations of any codes. Every permit issued shall become invalid
unless thervuork authorized:by such permit is commenced within six,months..of permit issuance, or if work authorized:-by
the perrhit'iti suspended or abandoned for a period of six(6)months after°the time'the work is commenced. An extension
may be requested, in writing,from the Building Official for a period--not to exceed ninety(90) days and will demonstrate
justifiable cause for the extension:"'If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER:- YOUR-;FAILURE TO RECORD A NOTICE.OF.COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE-FOR-IMPROVEIIIIENTSTO YOURVPROPERTY.-IF YOU'INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR.-LENDER OR AN AVORN&BEFORE'RECORDING YOUR'NOT ICEOF COMMENCEMENT.
FLORIDA JURAT(F.S.M_IWLJAL�
OWNERsOR AGENTCONTRACTaR
Sutiscritied and swom to r affirmed Before this Subscribed and sworn affirmed before me this
b TAMPS MA S b IES BOWIE CLARK
o s are personally known o r has/havq produced o islare erSnrimilvi known to r hasihave produced
as identification. as identification.
40 Notary Public Notary Public
Commission No.GG 308696 Commission No. GG 308696
Daphne Clark Daphne Clark
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped c8 DAP GG�S6g6
��rPue� DAPHNEA:CCWK zoti�;...,,�% COmmission#
r°•• '• ° Commission#GG 308696 ¢ Eypites June 2 2s
* e Expires June 27,2023w*e * Ttr+�O"'
9 tom°
tA?y y,° Ba+de4iMiei�etHof�Y ' �OFV,0417
�0F F`�
04-26-21-0260-00000-0170 1 Pasco County Property Appraiser https://search.pascopa.com/parcel.aspx?parcel=2126040260000000170
Parcel ID 04-26-21-0260-00000-0170 (Card: 1 of 1)
Classification 00000-Vacant
Mailing Address Property Value
LINKS AT CALUSA SPRINGS LLC Ag Land $0
2301 LUCIEN WAY STE 260 Land $23,079
MAITLAND, FL 32751 Building $0
Extra Features $0
Physical Address
6825 SHELBY LYNN WAY, Just Value $23,079
ZEPHYRHILLS, FL 33542
Assessed (Non-School Amendment 1) $23,079
Legal Description (First 200
characters)
Non-School Taxable Value $23,079
See Plat for this Subdivision School District Taxable Value $23,079
LINKS AT CALUSA SPRINGS PB 81 PG
074 LOT 17
Jurisdiction
CITY OF ZEPHYRHILLS
_ Land_ Detail (Card: 1 of 1)
Line :Use_ _Code Description_ Zoning-Units _,Type- 'Price Condition Value
1 0100V LP1-1 — SFR OPUD 5,495.00 SF $6.00 0.70 $23,079
_ Additional Land__Information
Acres Tax Area FEMA Code — Neighborhood Code(s)
0.13 30ZH -- LKCS
Building Information (Card: 1 of 1)
Unimproved Parcel
Extra Features (Card: 1 of 1) _
Line ;Code (Description v _ Year iUnits ;Value _
No Extra Features
Sales History
Previous Owner: UNITED CAPITAL FUNDING CORP
Month/Year !Book/Page jType _ -1,DOR Code !Condition Amount
10/2019 9987 / 0218 _' Warranty Deed 05 Vacant $2,760,000
04/2016 9350 / 2262 Certificate of Title 12 Vacant $0
12/2011 i 8639 / 3248 Warranty Deed 05 Vacant $0
11/2011 8627 / 0126 _ Warranty Deed --' _12 _ Vacant - -- $0 _
05/2008 j 7848 / 0427 Quit Claim Deed Vacant $0
05/2008 ! 7836 / 1714 Certificate of Title Vacant $0
1 of 1 2/8/2021, 11:15 AM
FORM R405-2020 STATE COPY
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KH02743 Ivanhoe(TAM) Builder Name: K Hovnanian Homes
Street: 6825 Shelby Lynn Way Permit Office: City of Zephyrhills
City,State,Zip: Zephyrhills,FL,33542 Permit Number:
Owner: Jurisdiction:
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Type$2785.3 sqft.) Insulation Area
2. Single family or multiple family Detached a. Frame-Wood,Exterior R=11.0 1312.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 1112.20 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 361.11 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
5. Is this a worst case? Yes 11.Ceiling Types (1610.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1610.00 ft2
6. Conditioned floor area above grade(ft2) 2666 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
7. Windows(211.1 sqft.) Description Area 12.Ducts R ft2
a. U-Factor: Dbl,U=0.34 109.75 ft2 a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 274.3
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.34 61.19 ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.29 a.Central Unit 33.1 SEER:15.00
c. U-Factor: Dbl,U=0.63 40.20 ft2
SHGC: SHGC=0.32 14.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 1.000 ft. a.Electric Heat Pump /hr HSPF:8.50
Area Weighted Average SHGC: 0.265
8. Skylights Area
c. U-Factor:(AVG) . N/A ft2 15.Hot water systems
SHGC(AVG): N/A a.Electric Cap:50 gallons
9. Floor Types (2666.0 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1131.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 1056.00 ft2 None
c.other(see details) R= 479.00 ft2 16.Credits Pstat
Glass/Floor Area: 0.079
Total Proposed Modified Loads: 80.93 PASS
Total Baseline Loads: 80.61
I hereby certify that the plans and specifications covered by Review of the plans and O�Z14E S744
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code. ti rr�r, , •' f ,° ,;,,, O
PREPARED BY: Before construction is completed
DATE: ?_1_ n24 this buildingwill be inspected for
P
compliance with Section 553.908 t.
hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code. CODS
OWNER/AGENT:- Sara.7'.iZ0Ve1a. BUILDING FI�I/,�L:ZU
DATE: 2/8/2021 DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.60 ACH50(R402.4.1.2).
1/25/2021 1:51 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5