Loading...
HomeMy WebLinkAbout21-1514 .a J101110flr City of ZephyrhillS PERMIT NUMBER L - 5335 Eighth Street Zephyrhills, FL 33542 BNR-001514-2021 Phone: (813) 780-0020 - Issue Date: 03/18/2021 Fax: (813)780-0021 Permit Type: Building New Residential Property Number Street Address 04 26 21 0260 00000 0190 1 6809 Shelby Lynn Way Owner Information Permit Information Contractor Information Name: LINKS AT CALUSA SPRINGS LLC Permit Type:Building New(Residential) Contractor: LINKS AT CALUSA SPRING! Class of Work:SFR Construct LLC Address: 2301 Lucien Way 260 Building Valuation:$148,230.00 MAITLAND,FL 32751 Electrical Valuation:$6,300.00 Phone: Mechanical Valuation:$5,200.00 Plumbing Valuation:$5,900.00 Total Valuation:$165,630.00 / (_ 7_ Total Fees:$14,799.28 Il Amount Paid:$14,799.28 Date Paid:3/18/2021 2:16:51 PM Project Description CONSTRUCT SINGLE FAMILY 2,403 SQ FT-LAC Application Fees Building Permit Fee $771.15 Sewer Connection Residential Fee $2,090.00 Address Fee $30.00 Mechanical Plan Review Fee $33.00 Driveway Fee $45.00 Public Safety Impact Fee-Admin $26.35 Irrigation 3/4 Meter(Calc) $732.71 Electrical Plan Review Fee $35.75 Plumbing Plan Review Fee $34.75 SIF 1 percent Fee $83.28 Building Plan Review Fee $385.58 School Impact Fee $8,328.00 Public Safety Impact Fee-Police $254.00 Mechanical Permit Fee $66.00 3/4 Water Meter Fee(Calc) $732.71 Electrical Permit Fee $71.50 Plumbing Permit Fee $69.50 Water Connection Residential Fee $1,010.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ,y1QgL4_)L-*rn CONTRACTOR SIGNATURE PE 7MIT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE1111 :4 -._FOR CITY OF,.ZEPHYRHILLS BILLING CONTACT LINKS AT CALUSA SPRINGS LLC $0.1 2301 LUCIEN WAY 260J MAITLAND, FL 32751 2 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00002845 03/16/2021 03/16/2021 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-001514-2021 3/4 Water Meter Fee(Calc) $732.71 Address Fee $30.00 Building Permit Fee $771.15 Building Plan Review Fee $385.58 Driveway Fee $45.00 Electrical Permit Fee $71.50 Electrical Plan Review Fee $35.75 Irrigation 3/4 Meter(Calc) $732.71 Mechanical Permit Fee $66.00 Mechanical Plan Review Fee $33.00 Plumbing Permit Fee $69.50 Plumbing Plan Review Fee $34.75 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 Sewer Connection Residential Fee $2,090.00 SIF 1 percent Fee $83.28 Water Connection Residential Fee $1,010.00 6809 Shelby Lynn Way Zephyrhills, FL 33542 SUBTOTAL $14,799.28 REMITTANCE INFORMATION TOTAL $14,799.28 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 March 16,2021 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 FASCO COUNTY, FLORIDA, Permit No. Date Permitted 2 ' yBuilder Name/Owner Name E� 7+" �—� - Control#' County Parcel No.() 2_�2-1 b ) SubDIv: /r� dc'/z � Address/Locatlon h/!. cli- ClassiflcationlType of UsgI �C(i TRANSPORTATION IMPACT FEE . Rate: Sq.Ft Unit: i ' Exempt ❑Yes Q No How Determined Impact Fee Amount $. Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount (057) Mobile Home (058) Other Residential 123) Collection Fee ` Exempt [�Yes. ❑No How Determined PARKS:AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone _ TOTAL AMOUNT $ '• � Exempt ❑Yes ❑No How DetePmined LIBRARY FEE �- Land Accounf Land Credit Land Total Facility Account Facility Credit Facility Total Exempt (]Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOl1NTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE•OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY INSTR#202102695E OR BK 10276 PG 1452 Page 1 of 1 02/09/2021 02:13 PM Rcpt:2259108 Rec:10.00 IDS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller Parcel ID Number:04-26-21-0260-00000-Q 19 0 Prepared By Daphne Clark and K Hovnanian Homes Return To: 2301 Lucien Way,Suite 260 Maitland,FL 32751 NOTICE OF CONIIVIENCEMENT. State of Florida. County of PASCO. The undersigned hereby gives notice that improvements will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement. 1. Description of property: LOT 19 Legal Description: LINKS AT CALUSA SPRINGS according to the plat thereof,as recorded in Plat Book 81 Page 74-79 of the public records of Pasco County,Florida. Addresses G 809 She I bu Ly nn U A j Zephyrhills FL 33542 2. General description of improvements: New Single Family Home 3. Owner information: Name Links At Calusa Springs,LLC Address 2301 Lucien Way,Suite 260,Maitland,FL 32751 4. Fee Simple Title Holder:N.A. 5. Contractor name and address: Name K.HOVNANIAN FLORIDA OPERATIONS,LLC Address 2301 Lucien Way,Suite 260,Maitland,FL 32751 6. Surety:N.A: 7. Lender:N.A. 8. Persons within the State of Florida designated by the Owner upon whom notices or other documents may i be served as provides by 713.13(1)(a)7.,Florida Statutes: N.A. 9. In addition to himself,Owner designates the following to receive a copy of the Lienor's Notice as provided in 713.13(1)(b),Florida Statutes. N.A. 10. Expiration date of notice of commencement:One year from the date of recording. WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTENT TO OBTAIN FINANCING,CONSULT YOUR LENDER OT ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. 11.Date Signed: 21$102 r Signature of Owner's Agent: Ja es Maki nsky Sworn to and subscribed before ale this' 1 vl 2021 by James Mmkransky who is personally known to me. Notary Public. " '. vry DAPHNtiACLARK .• � myssionll GG 368695 Daphne A Clark 'l'j• ., . plrasJune27,�23 My commission expires:6/27/2023 + 60*0 Serial No:GG 308696 : N ry Signature: ; oe�' eoosd�ry seal: oF� aP:r iBf��Q/S State Of Florida,County Of Pasco This is to certify that the foregoing is a o true and correct copy of the document on file or of public record in this office. dot- it ess my hand and official seal this day of - ,b 2®c T �� �a, Nikki Alvar wiles,Esq.,CI &Comptroller 0• �� ��' Pasco Co Florida �� ®�- By , Deputy Clerk 813-780-0020 City of Zephythills Permit Appliaifbn Fax-Eli3-780-0621 Building Department Date Received :1 one Contact fbr.Permitting 257 -6940 Ph F4071 owner's Name LINKS AT CALLISA SPRINGS. LLC Owner Phone Number 407-257-6940 Owner's Address 1. Lucien Way, Ste 260, Maitland FL 32751 Owner Phone Number Fee Simple Titleholder Name N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS (E(25:_,9_0-9—Ske1b,9 L rNr, WO. 7epkj rh,,115 1-1 33542l LOT# SUBDIVISION LINKS AT CALUSA SPRINGS PARCEL ID# 04-26-21-0260-00000�)0_ (OBTAINED FROM PROPERTYMNOTICE) WORK PROPOSED =V NEW CONSTR ADD/ALT SIGN LJ DEMOLISH INSTALL R REPAIR PROPOSED'USE SF.R X F-71 COMM OTHER TYPE OF CONSTRUCTION BLOCK iFRAME STEEL DESCRIPTION. .OF WORK NEW SINGLE FAMILY HOME Total Sq Ft,_�403 A: ILMng, BUILDING SIZE TOTAL Under Roof SQ FOOTAGE Area HEIGHT 12 11 WWI 14 1 W I i i I R i I ®BUILDING ao VALUATION OF TOTAL CONSTRUCTION T3 , 00 [XDELE&TRIC AMP S 6 300.AL 17F" ERVICE 150 PROGRESS,ENERGY F ®PLUMBING 5,900.00 ®MECHANICAL 1' 5,200.00 VALUATION OF MECHANICAL INSTALLATION =GAS .[E ROOFING F__1 SPECIALTY = OTHER' FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA F­1YES ®.NO I i fl�iii�1 4444 PUILDER' 1K HOVNANIAN FLORIDA OPERATIONS,LLC SIGNATURE REGISTERED I YIN FEE CUR COMPANY REN 2301 Lucien Way,Ste 260,,Maitland FL �263047­ -Address License PCI ELECTRICIAN ROBERSTON ELECTRICAL SERVICES, INC SIGNATURk [4 COMPANY RE61STFAED I Y/ N FEE CURREN LYLN _J Address F16812 Silver Shores Lane,Odessa,FL 33556 [:EC13002645 PLUMBER COMPANY BAYONET PLUMBING, HEATING St AIR-COND.LLC I NATURE. T REGISTERED Y/`N '"FEE CURREN LY _L N_J dress P.O.Box 5308,Byonet Pdint,FL34674 '--Ucense#°FCFC042998 MEC AN COMPANY AIR FLOW DESIGNS, INC. SIG;A TU� ✓ REGISTERED I YIN, I FEE QURREN Y_.LN J 250 Jasmine Rd.,Casselbegy FL 32707 License# f—qAC1814423' Address OTHER RO HUdH MACDONALD/ALVAREZ ROOFING SIGNATURE COMPANY REGISTERED I Y/ N FEE qUI1REh LYLN J 10825 Tom Folsom Rd.,Thonotosassa,FL 33592 CCC1329662 Address License# = Hl RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of.Energy Forms;R-04V Permit for new construction, MI-619mum ten(10)working days after submittal.date. Required ondite,Construction Plans,Stormwater Plans w/Silt Fence instali6d, Sanitary Facilities&1 dtimpster;Site Work Permit for subdivisionsnarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of.Enetgy.Forms.R-O-W Permit for.new-construction. MinImUM ten(10)workin,g,days after submittal date. Required onsite,Cons truction Plans,.Stormwater Plans W/Silt Fence installed, Sanitary'Facilides&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2'sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. ------------- ..............T.................... Fill,out application completely. Owner&Contractor sign,back of application,notarized If over$2500,a Noticei,of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PlottSurvey/Footage) Driveways-Not over Counter if on public roadw6ys..needs ROW �r PLOT PLAN (NOT A SURVEY) DESCRIPTION:LOT 19, b LINKS AT CALUSA SPRINGS, a AS RECORDED IN PLAT BOOK 81, BASIS OF BEARINGS: �1 PAGES 74-79,OF THE PUBLIC RECORDS CIL OF RIW OF SHELBY LYNN WAY OF PASCO COUNTY,FLORIDA. BEARS S.02°03'37"W.PER PLAT. rn THE PROPERTY DESCRIBED HEREON IS LOCATED IN FLOOD ZONE")(" PER FLOOD INSURANCE RATE MAP NUMBER 12101C 0289F,EFFECTIVE DATE SEPTEMBER 26,2014,COMMUNITY No.120235 PANEL 0289 F. LOT 18 1 d i U m ' 'BS• "•SO• 0 i d U I `° S.87°56'23"E. 108.00, 16 1 I —By-a a` H ' ide Setback a Pa o'es -------------ram I 0 I i I U) LL 12.801 ' I ago } i I O ¢ 6 m #6e09 PmPosed I N x 1 {I 15.00, O I d- w op`Y. 0 1 N.— Proposed House Entry ,O.B I 31 I PADUE LO ai Plan-Dupont-A Io- I I Z o V Z P)lanal ^, �- d ("M I ED .0'OL Ge2ge-LEFT " I } c='J °° 5,20' O 12.80'I to Proposed Lavest FloorEla �0 Ol i U eh CD I _� Approved GradiniO3,84g Plan. LOT 19 !� I H d m � O I I w Approved Grading Pan. y I OM a Z vly 1 m 1 r„ ? o _I - 1I CV LLI yi 70.00'L------- —— o'os I Cn fn 9'Sidesetback --'--'---- -----. �5.20. N.8705623"W. 108.001 - I to LOT 20 ZJ LEGEND: PWE=APYYCORPS DF BBGWFeA6 EwF•6AN]EY wREHEYCE rH•D•iWrID NLL&DIM La 391] P.AD UE=PPoVAn AC[E6S rmvwa IUNrEG6DTHi—SEN—) DWJNAGEa W&ICURINEAEeIFM IOI=CRCUAi® TAPS=FOgLRA6P—sna ASP=req PPPROVED6UEWAt1(PIFN ®NfAHETREN51gA PoEER W.NYAYCHOR PA•PPOreRNLME �aEARNG OA.HONEDMBEP6ASSOdAnoH PrC=PoLNNIILCILLORYE Cdt=dAIIFI®CONNFARECdA6 ImPE•HbIDEN6nYP¢YE1NYlFXE (RI•aODIK an=wauuxmDEvaorYExr RPE p{e.gILN6 gST1nCi 0=OENMFAnON PEINWRdI]NNdEn RPE d•NPo31Mfr �•INm•s.BPE WEss CIF. �gWAYwYFe1C S OYOR -WATRT W`fANOYgRRYE NEO=YATdl En611NG GRPOE SEC=6ECTION -WATFAVALVE mP•CdWUGATe]NEfN.PIPE YH=NANHttE 11YP•iOVMSHIP C=CONCRETE I I•NONAAYL4 RGE.RANGE NREHYDM iT•dTY OFT—A �q.xOgrHAyEyy°pH 61R=Sn'SETLROx R00 CA•d3rIEALWE =FN6a TACK EEr OE•ORNNAGEEASFMQAr VQinCALDALUN IBA! La 3B1] NGIO•HAnONAL GENETC 3!A=6ETMAleOW(ra]BI] DaAE=D�IHAGEANOA[CF56 =UTH SEr w+ncraonrina ls]A sPK•6EraAnKEaxxoxxu DYE=OR.wIAf>EArmlxaarss�EGRrss xrs=xoT ra scA.E sAFnYo=soumWEsr RgAo.AwATER Qf.unYTVParE FAs�rm ccrarnREDORDs uuacelwrdsrwcr Dau=OPALVAGEAYOURIN —OUL-gvEPoIFM UiILINYNE6 1aN•IEYPoRAPleENCIMARK aEv.=IaprAnox P cPa PenAPrnovm Drt emDRAH =u]al°LLrvArnDRNne�E 4�R=EtEV.(PAfPI NO TREES per approved PAVING, e'dBC•FNNPONNFMHFRoiECnoX ppO�p=PERAPPPOVIDGRADINO WGRE65A:GRE66E/SeIEM ' GRADING AND DRAINAGE PLAN-B. dlYwsNcx oFlalseoaauGx AAO DPAIrvAOE RAx uE=unnrFwmlrxr Pa=RAT— WC=YdME66COPNER Drainage E5ar•EA69IaBi 11—m FINIEA6ECngA Nc9_WEIWY—on FW=FNtO CONCREIEYONUNEM PC•PoINTOFNRVANPE EASBIE .na FIGW a w°Nmmq RPE PCL=rOWTOFCCNPOGr9 m wrwa=wE wroco"6a`°A"q] 'o—"'T"= Sidewalks&Gutters per approved PAVING, rm=S4 rcuxo woxaco,ressl] PCP•PElw.w�BAT.-... AREASETaicauxE Arrow alaE DiIEAW+EEHD,rfl, PRD=19RATnrRE4ER6ENRnE wT=—rEHDE GRADING AND DRAINAGE PLAN-B. .. flO•�Ixo --i—Tora n0c wAaE=weulamscraEAAmeurrFR N RK=Fdrtp PA¢'ERWION NAL PoC=rbWr OFPANNEHLEYFM FASEIABII N FOF.WFOnE•ROPoM[iWENO RUA•PEWJAxEMPFFFAEN[ENONWBrT co WArOR6HCW]IISYON RS.PNOFESSIONk LONO SURVEYOR ii xsERwnoxEAmrExr Psr=PRorFseaxN.wavEYoxeuawER Datum Conversion N SOD AND CONCRETE CALCS NGVD 1929-0.84'= (NAVD 1988). m Total Lot Area in Total Sod Area in Total Concrete Total Cona Walk A/C Pad Percent proposed Lot II CAL DATUM NOTE: y Square Fe SquareFeelt SquuareFeeti pnSddalonLot)Community Feetrt Coverage± LotGr(PAGP,pe AREEVERTILEVA ELEVATIONS SHOWN HEREON IIIIIIIIIIuIIW011lllllllll IIIIuIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Walk an Lot) ARE REFERENCED TO NGVD 1929. u Wu u N 5495 25o4 291 288 9 41% A zcle 211112. m I This Sketch Prepared For : K.Hovnanian Homes N a U Gi Description R E V ID to Dwn. Ck'd Order No. opt R. FQ� Dually signed a �( ' colt R CERTIFICATE b ler o a FLOaDA te: 2021.02.04 En meerin &Surveying Corporation °`A"°s 5:45:47 -05'00' � a 8515 Palm River Road Tampa,Florida 33619 a ATE Gr (B13)621-7841 (813)664-1832(fax) M Client No:2018 SCOTT R. FOWLER SIGNATURE vwvw.lesc.com L.B.#3913 Drawn:TJW FEB.01,2021 a o Checked: FLORIDA REGISTERED LAND SURVEYOR NO. 5185 3 Original No.: 22111224 lCurrent No.:22111224 Survey Date: NIA a Sec.: 4 Twp.: 26 S Rge.: 21 E 04-26-21-0260-00000-0190 1 Pasco County Property Appraiser https://search.pascopa.com/parcel.aspx?parcel=2126040260000000190 Parcel ID 04-26-21-0260-00000-0190 (Card: 1 of 1) Classification 00000-Vacant Mailing Address Property Value LINKS AT CALUSA SPRINGS LLC Ag Land $0 2301 LUCIEN WAY STE 260 Land $23,079 MAITLAND, FL 32751 Building $0 Extra Features $0 Physical Address 6809 SHELBY LYNN WAY, Just Value $23,079 ZEPHYRHILLS, FL 33542 Assessed (Non-School Amendment 1) $23,079 legal Description (First 200 characters) Non-School Taxable Value $23,079 See Plat for this Subdivision School District Taxable Value $23,079 LINKS AT CALUSA SPRINGS PB 81 PG 074 LOT 19 Jurisdiction CITY OF ZEPHYRHILLS — _ Land Detail (Card: 1 of 1) Line Use _Code ;Description Zoning Units Type Price _Condition Value _ 1 0100V LP1-1 SFR OPUD 5,495.00 SF $6.00 0.70 $23,079 Additional Land Information --- ----- - ----- --- -- — - --------------- ---------- Acres _ Tax Area _ FEMA Code_ _ Neighborhood Code(s) 0.13 30ZH -- LKCS Building Information (Card: 1 of 1) Unimproved Parcel Extra Features (Card: 1 of 1) Line Code :Description ;Year Units Value No Extra Features Sales History Previous Owner: UNITED CAPITAL FUNDING CORP M_onth/Year Book/Page _ Type _ DOR Code 'Condition _Amount_ 10/2019 i _9987 / 0218 Warranty Deed 05 Vacant $2,760,000 — 04/2016 _9350 / 2262 _ Certificate of Title - 12 Vacant _$0 _ 12_/2011 8639 / 3248 _ Warranty Deed 05 _ Vacant $0 — 11/2011 _8627_/ 0126 - ----Warranty Deed 12 ___ Vacant $0 _ —05/2008 _ 7848 / 0427 - _ Quit Claim Deed _ _ _ _ Vacant $0 05/2008 7836 / 1714 Certificate of Title Vacant $0 1 of 1 2/8/2021, 11:19 AM STATE COPS( FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHO1830 Dupont(TAM) Builder Name: K Hovnanian Homes Street: 6809 Shelby Lynn Way Permit Office: City of Zephyrhills City,State,Zip: Zephyrhills,FL,33542 Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type�1692.9 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1412.70 ft2 b.Frame-Wood,Adjacent R=11.0 280.22 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 11.Ceiling Types (1830.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1830.00 ft 6. Conditioned floor area above grade(ft2 1830 b.NIA R= ft2 Conditioned floor area below grade(ft2) 0 c. A R= ft2 7. Windows(158.1 sqft.) Description Area 12.Ducts R ft2 a. U-Factor: Dbl,U=0.34 101.94 ft2 a.Sup:Attic,Ret:Main,AH:Main 6 250 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.63 40.00 ft2 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 26.9 SEER:15.00 c. U-Factor: Dbl,U=0.34 16.19 ft2 SHGC: SHGC--0.29 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.530 ft. a.Electric Heat Pump 28.0 HSPF:8.50 Area Weighted Average SHGC: 0.259 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15.Hot water systems SHGC(AVG): N/A a.Electric Cap:50 gallons 9. Floor Types (1830.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1830.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 16.Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 56.64 PASS Total Baseline Loads: 56.44 I hereby certify that the plans and specifications covered by Review of the plans and tT34E S-P this calculation are in compliance with the Florida Energy specifications covered by this 4+ Code. calculation indicates compliance with the Florida Energy Code. ' PREPARED BY: �l � v lC/ Before construction is completed DATE: 2-1-2 2V this buildingwill be inspected for P compliance with Section 553.908 , hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. COD yyF,'L�� OWNER/AGENT: Scwac . ZNera. BUILDING OFFICIAL: DATE: 2/8/2021 DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 1/25/2021 12:22 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 4 O - MD • Single Family Dwelling Plan Review Comments 1. F;F E shall.be a minimum of 8" above the road-elevation-and an engineered site plan. 2.. .Lots shall:be graded to.coi'- y with R401:3:of the F.B.C. 3:. Compaction test required if 24".or more of fill.dirt is brought in at any one.place: 4: Tie in survey required before,pouring-concrete: - - 5: .Driveways require.a R,O:W use permit: All 4 sides--Of driveway thru the sidewalk shall have expansion material. 6. .All setbacks shall be met. -7. All.property:markers shall be uncovered.and marked at time:of first inspection. - 8: All A:D.A.requirements shall:be.xnet:.. 9; No electric,.plumbing;mechanical,or.framing shal .be:covered without an inspection and . approval-first. 10:-All Garages-shall comply with section:R302.6 of theF.B:C. (Fire Separation).: 1.1. Appliances.shall notb.e installed in a location where subject to mechanical damage unless protected by:approved barriers: M3034 of the EB.0 12..-Water heaters shall comply with section P607.3 of the F:B:C: 13. Foundation supports for A/C units..shall.be raised at least 3" above finished grade. M1308A . 14: Return air iri all bedrooms: F.B:C.. M1620:4 15. Smoke detectors.are to be installed in accordance with R313:1 of the F.B.C. 16. All glazing requirements are to be in accordance:with R308A of the F.B:C: 17. All means of egress are to be in accordance with R311 of the F.B.C: . 18. "Green gypsum board"shall riot be used as'a backer'in showers or tubs.R702:4:2 F.B.C. 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. - 20. Carbon monokide alarms will be required in new construction that uses fossil-burning heating. or appliances or an attached garage. They shall be installed in accordance with the F.B.C: 21. All plumbing,mechanical; and electrical shall be separate from unit to unit: This includes all underground plumbing grid electric. 22. All 2016 N.E.C. Codes will be enforced: 21 Tamper- Resistant Receptacles in accordance with 406.11 of the.2016 N.E.C. 24. In accordance with the.Land Development Code,lots..shall.be sodded before final at least_ 10 feet around the structure. 25. R403.5.3Hot Water.pipe insulation, Insulation for.hot:water pipe with'a minimum thermal resistance (R-value) of R-3 shall. be applied to the followin Piping'V.inch (19.1 mm)and larger in. nominal diameter. Piping serving more than-one dwelling unit. Piping located outside the conditioned space. Piping from thew at ef heater to a distribution manifold: Piping'located under,a floor slab. .Bred in piping, Supply and return piping in recirculation systems other.thari demand recirculation systems: 25. Blower-door test shall be provided Before CO: 26. A cony of the eneM.each shall be with permit at all times. 27. Cope of fnal-'insulation report shall be pr®vided with permit before rnaL 28. No fence,pool or screen enclosure':&issued.witliahis-permit.- F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6t'Edition R.O.W.'-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) 81:9-780-0020 City of Zephyrhills Permit Application Fax-7813-780-0021 Building Department Date Received Phone Contact for Permitting [407 -1 -257 &940 rTTM... ...... II33:CCC="rrr1 310 MMI-C-1-1 Owner's Name LINKS AT CALLISA SPRINGS. LLC Owner Phone Number 407-257-6940 Owner's Address 12301 Lucien_Way, Ste 260, Maitland FL 32751 Owner Phone.Number Fee Simple Titleholder Name- fN/A Owner.Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 0809 5- hel bA L Linn 0J, 2epb4ch,Its 335742 LOT# 19 SUBDIVISION LINKS AT CALLISA SPRINGS I PARCEL ID9 104-26-21-026Q-00000.0 0 {OBTAINED. FROM PROPERTY TAKINOTICE) WORK PROPOSED f—u-1 NEW CONSTR ADDIALT SIGN DEMOLISHINSTALL R REPAIR PROPOSED USE SFR X Q COMM OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL DESCRIPTION OF WORK'- NEW SINGLE FAMILY HOME Total Sq Ft BUILDING SIZE fOTAL Under Roof SQ FOOTAGE wng HEIGHT WWW W44441 11 IZDBUILDING $11111.1 VALUATION OF TOTAL CONSTRUCTION �ELECTRICAL $ AMP SERVICF150 PROGRESS ENERGY Q W.R.E.C. (PLUMBING $5,900.00 Z3MECHANICAL $__ VALUATION OF MECHANICAL INSTALLATION =GAS � ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES X NO. BUILDER 'COMPANY SIGNATURE REGISTERED Y/ N- FEE"CURREN A0dress Udensr6.# ELECTRICIAN COMPANY SIGNATURk REGISTERED Y/ NI FEE CURREN LILN J Address LiceniSe'4 COMPANY SIGNATURE REGISTERED CURREN I Y/N Q>O)< 119q , j)ovp Address ir, FL 53V2,) License#'FE0067q i-z o 7-o MECHANICAL COMPANY SIGNATURE REGISTERED I 'Y/ N1 FEE CURREN Address License 9 QtHERR00FER COMPANY SIGNATURE REGISTERED, I Y:/.N._j FEE CURREN Address License# P- RESIDENTIAL Attach Plot Plans,,(2)sets of Building Plans;(1)setpf Energy Forms;R-O-W Permit for new construction, Minimum.ten(10)working-days after submfti date. Req6ired'onglte,Construction Plans,Storinwater Plans wl Sift Fence installed, Sanitary Facilities&1 dUmoster,Site Work Permit for subdivisionsnarge projects COMMERCIAL Attach(2)complete sets of Building Plans plusa Ufe:Safety Page;(1)set,of Energy Formv.R-O-W-Permlt for new Construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,.Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions. Fill out application completely. Owner Contractor sign.back of application,notarized If over$2400,a.Notice of Commencement is required (AIC upgrades over$7500) Agentffor the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy.of contract required) Reroofs If shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Drivoways-Not over Counter if on public roadways-needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to°deed°restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: if the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both'the owner and contractor maybe cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,theyare advised to contact the Pasco County Building Inspection Division=Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractors) sign portions of the "contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor, that maybe an indication that he is not properly licensed and is'not entitled to permitting privileges in Pasco -County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that'Transportation Impact Fees and Recourse Recovery Fees may apply to'the construction of new buildings, change of use in existing buildings,.or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07;,as amended. The undersigned also understands; that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certficate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be.paid prior to.permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713; Florida Statutes,as amended): If valuation of work is$2,600.00 or more,.I certify that 'l, the applicant, have been provided- with a copy of the "Florida Construction-Lien Law Homeowner's Protection Guide prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that l have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement.. CONTRACTOR'S10WNER'S AFFIDAVIT: 1.certify that all.the information in this application is accurate and that all work will be done in compliance with all applicable taws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do Work-and' ins-Wiation at:indicated. I certify that no work.or installation has commenced,prior to issuance of a permit and that.all work will be performed to meet standards of all laws regulating construction;,.County,and'City codes, zoning regulations, and Iand'deVelopment regulations in the jurisdiction. I also certify that-1 understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas'and Environmentally Sensitive Lands,'Water/Wastewater Treatment. Southwest Florida Water Management District Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks, NavigableWaterways. - Department of Health & Rehabilitative Services/Environmental -Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US'Environmental Protection Agency-Asbestos abatement. Federal-Aviation Authority-Runways. I understand that-thefoilowing restrictions apply to the use of fill: Use of-fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used In Flood Zone "k. , it is understood that a drainage ,plan addressing a .compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used'in Flood Zone "A" in connection with a permitted building using stem wall construction;"1-certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of.such fill will not adversely affect adjacent properties: -If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre wtieh,are,elevated by fill,an engineered drainage plan is required. If I am.the.AGENT�POR`:T�IE OWNER, I promise in good faith to inform the owner of the permitting conditions set-forth in this affidavit-brior to commencing.construction. i understand that:a separate permit may be required for electrical work, plumbing,-s rit; welts,:-;pools;`a'ir-conditioning, gas, or other installations not specifically included in the,application. A permit'issued shall be=construed to be a license to proceed with,the inrork and not as authority to violate, cancel, alter, or set asitle:any.provisions`",of:the'.technical codes, nor shall issuance of.a permit prevent the Building Official from thereafter of requiring,a correction errorsin.plans,construction or violations of any codes. 'Every permit issued shall become invalid unless theyuorkrauthorized 6y such permit is commenced-within six months,-of-permit issuance, or if work.authorized"by the permitiis suspended or.abandoned for a period of six(6)months after,the:time'the work is commenced. An extension may be requested, in writing,,from the_Building Official for a:period.not to exceed ninety(90) days and will demonstrate justifiable cause for the extension""If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO.OWNER:- YOUR-;FAILURE.TO RECORD A NOTICEOF.COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE-FOR IMPROVEMENT$TO YOUWPROPERTY. IF YOU INTEND TOOBTAIN FINANCING,CONSULT WITH YOUR tLENDER.OR AN ATTORNEY BEFORE'RECORDING YOUR'NOTiCE OF COMMENCEMENT. FLORIDA JURAT(F.S. 7.03) OWNER OR AGENT CONTRACTOR -)- Subsc led and swom to or affirmed) efore m this Subscribed and sworn to a BOWIE re eARK b A ES MAK S o s are personally known Dr has/havelprpduced o islare ersonall known to r haslhave produced a identificatio as identification. } Notary Public Notary Public Commission No. GG 308696 Commission No. GG 308696 ' Daphne Clark Daphne Clark Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped C1.P� DAFNKE�'Co DAPKNE A GG 3086� ot�gr Puevc on#GG 308696 t�gY PUB��c mm%gon# 023 a * Comm 2023 dune 2 s * Wires June 275 sew p,�TDNB"� ul ?A OF rM1 9�OF�o