Loading...
HomeMy WebLinkAbout21-1517 F v " City of Zephyrhilis PERMIT NUMBER r 5335 Eighth Street Zephyrhills, FL 33542 BNR-001517-2021 Phone: (813) 780-0020 Fax: (813)780-0021 Issue Date: 03/18/2021 Permit Type: Building New Residential Property Number Street Address 04 26 21 0260 00000 0690 6828 Shelby Lynn Way Owner Information Permit Information Contractor Information Name: LINKS AT CALUSA SPRINGS LLC Permit Type:Building New(Residential) Contractor: K HOVNANIAN FLORIDA Class of Work:SFR Construct OPERATIONS LLC Address: 2301 Lucien Way 260 Building Valuation:$215,946.00 MAITLAND,FL 32751 Electrical Valuation:$6,300.00 Phone: Mechanical Valuation:$5,200.00 Plumbing Valuation:$5,900.00 ^ (- Total Valuation:$233,346.00 J� Total Fees:$15,307.14 Amount Paid:$15,307.14 Date Paid:3/18/2021 2:27:38PM Project Description CONSTRUCT SINGLE FAMILY 3,264 SQ FT LAC Application Fees Sewer Connection Residential Fee $2,090.00 Plumbing Permit Fee $69.50 Address Fee $30.00 Public Safety Impact Fee-Police $254.00 SIF 1 percent Fee $83.28 Electrical Plan Review Fee $35.75 Irrigation 3/4 Meter(Calc) $732.71 Plumbing Plan Review Fee $34.75 Building Permit Fee $1,109.73 Public Safety Impact Fee-Admin $26.35 Water Connection Residential Fee $1,010.00 Building Plan Review Fee $554.86 3/4 Water Meter Fee(Calc) $732.71 Electrical Permit Fee $71.50 Mechanical Permit Fee $66.00 Driveway Fee $45.00 Mechanical Plan Review Fee $33.00 School Impact Fee $8,328.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. LZ - ,q I Q 9 CON SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICEI B fi l FOR CITY OF 7--EPHYRHILLS BILLING CONTACT JAMES CLARK K HOVNANIAN FLORIDA OPERATIONS LLC 2301 LUCIEN WAY STE 260 MAITLAND, FL 32751 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00002843 03/16/2021 03/16/2021 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-001517-2021 3/4 Water Meter Fee(Calc) $732.71 Address Fee $30.00 Building Permit Fee $1,109.73 Building Plan Review Fee $554.86 Driveway Fee $45.00 Electrical Permit Fee $71.50 Electrical Plan Review Fee $35.75 Irrigation 3/4 Meter(Calc) $732.71 Mechanical Permit Fee $66.00 Mechanical Plan Review Fee $33.00 Plumbing Permit Fee $69.50 Plumbing Plan Review Fee $34.75 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 Sewer Connection Residential Fee $2,090.00 SIF 1 percent Fee $83.28 Water Connection Residential Fee $1,010.00 6828 Shelby Lynn Way Zephyrhills, FL 33542 SUB TOTAL $15,307.14 REMITTANCE INFORMATION TOTAL $15,307.14 City of Zephyrhills 5335 8th Street Zephyrhills,FL 33542 March 16,2021 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 s PASCO COUNTY, FLORIDA Permit No. 51 Date Permitted Builder Name/Owner Name f� Z`� Control# County Parcel No. SubDiv: LS' LG Address/Location t �'� 4n ClassiflcationiType of Usg TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: L Exempt- Q Yes [] No How Determined Impact Fee Amount ,�, Zone No. TAM SCHOOL IMPACT FEE � Account (056) Single=Family Detached House Amount $ �Ax1,?—A_____ t (057) Mobile Home 1 (058) Other Residential 123) Collection Fee Exempt [ Yes No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ '-Z4,, l°,6 3 Exempt ❑Yes ❑No How Deteirmined� LIBRARY FEE ` Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMO!#NTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Ackifowiedoement below does not Imply acceptance of concurrence,but simply recelpt of a copy of time form,placing the building permit owner-on notice of tide assessment and the conditions of payment for some. DATE RECEIVED BY RECEIPT NO. DATE BY INSTR#2021026950 OR BK 10276 PG 1 447 Page 1 of 1 02/09/2021 02:13 PM Rcpt:2259108 Rec:10.00 DS:0.00 IT:0.00 Nikki AlvarezSowles,Esq.,Pasco County Clerk&Comptroller • r Parcel ID Number:04-26-21 -0260-00000-0 69 0 Prepared By Daphne Clark and K Hovnanian Homes Return To: 2301 Lucien Way,Suite 260 Maitland,FL 32751 NOTICE OF COMMENCEMENT. State of Florida. County of PASCO. The undersigned hereby gives notice that improvements will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement. 1. Description of property: LOT Legal Description: LINKS AT CALUSA SPRINGS according to the plat thereof,as recorded in Plat Book 81 Page 74-79 of the public records of Pasco County,Florida. Addresses G 82 8 $he 1 b!, L.l i%n W gL j Zephyrhills FL 33542 2. General description of improvements: New Single Family Home 3. Owner information: Name Links At Calusa Springs,LLC Address 2301 Lucien Way,Suite 260,Maitland,FL 32751 4. Fee Simple TItle Holder:N.A. 5. Contractor name and address: Name K.HOVNANIAN FLORIDA OPERATIONS,LLC Address 2301 Lucien Way,Suite 260,Maitland,FL 32751 6. Surety:N.A. 7. Lender:N.A. 8. Persons within the State of Florida designated by the Owner upon whom notices or other documents may be served as provides by 713.13(1)(a)7.,Florida Statutes: N.A. 9. In addition to himself,Owner designates the following to receive a copy of the Lienor's Notice as provided in 713.13(1)(b),Florida Statutes. N.A. 10. Expiration date of notice of commencement:One year from the date of recording. WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY,A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTENT TO OBTAIN FINANCING,CONSULT YOUR LENDER OT ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. 11.Date Signed 12ov Signature,otOwner's Agent: Ja s Makr nsky Sworn to and subscribed before me•this 2 2(�2•l.i by James Ma nsky who is personally known to me. Notary Public DAP ��ytr�bq�,o IiNEA CLAttK Commtaston*GG 3t18G`J8 Daphne A Clarkale �� * Ex4 $4una2.7.2023 My commission expires:6/27)2023'' .y; �e� ,anwwaads" Serial No.GG 308696 Notary Signature: '�'0FF`° 9 ary seal: $Me Of Iflorldtii,County Of P6666 9°h1§is to qortlfy that tho forGaging ig a truo end comsat appy of th@ omment on file or of p0llo r @P(3fd In thin office. al this 2s my hewsn offielal so -$i Wltn 2 Q Nikki Alvar les,Esq.,Cler Comptroller Pasco Cou rida Deputy Clerk r 813-780-0020 City Of2ephyrhillS Permit AOplicgfbn .Fax-813-78M021 `Building Department Date Received Phone Coritact for.Permittins . 407 257 —6940 LINKS AT CALUSA SPRINGS. LAC Owner's Name. Owner PBone Number. 407-257-6940 Owner's Address . 2361 Lucien UVay, Ste 260, Maitland FL 32751 Owner Phone Number •Fee'Simple Tltleholder Name CN/A Owner Phone Number Fee Simple i Itieholder Andress N/A _71 .fps ADDRESS. t;Ci S-L, SheI b2 Lq nn U69 , -2ep K4 rk,IIs,FL 33542 LOT# susaiiinsiOw LINKS AT CALUSA_SPRINGS PARCEL ID# 04-26-21-0260-00000 a to q 0 (OBTAINED FROM PROPERTY_ TAXNOTICE) WORK PROPOSED Pq mEw cordsTR B ADD/ALT SIGN Q Q DEMOLISH .INSTALL REPAIR PROPOSED USE ® SFR X M COMM OTHER TYPE.OF CONSTRUCTION ® BLOCK C:] FRAME [ ,� STEEL. Q DEscRvnbNoFWoRK: NEW SINGLE FAMILY HOME Total Sq F IZ-G-1—) . TOTAL Under Roof ~ Giving BUILDING SIZE ... ✓-2t SQ.FOOTAGE,Area(2�q�o�oi HEIGHT —r-- [nBUILDING VALUATION OF TOTAL CONSTRUCTION ®ELECTRICAL $ AMP SERVICE'150 EX] PROGRESS ENERGY Q W.R.E.C. .6,300.00 [K]PLUMBING $ 5,900.00V� ®MECHANICAL $ 5,200.00 VALUATION OF MECHANICAL INSTALLATION =GA5 ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS j 3, $ FLOOD ZONE AREA AYES M NO, BUILDER �� (I coMPAMY K HOVNANIAN,FLORIDA OPERATIONS,LLC SIGNATURE 4 OV w" ' REGISTERED Y/ N FEE CURREA Y./N •Address 2301 Lucien Way,Ste 260,.Maitland FL 32751 License#' CBC1263047' ELECTRICIAN COMPANY ROBERSTON ELECTRICAL SERVICES, INC SIGNATURt;' �`^'}`^ ' ' :REGISTERED Y/.N .. E cuRREr, Y/N Address 16812 Silver Shores Lane Odessa FL 33556 License# F EC13002645 t?LUMIBER COMPANY BAYONET.PLUMBING HEATING&AIR-COND.LLC SIGNATURE. 4 REGISTERED Y/'N `FEE CURRD Y/.N Address P.O.Box 5308,Bayonet Point,FL34674 t:icense# CFC042998 MECHM16AL �:,_j� /j COMPANY AIR FLOW DESIGNS, INC. SIGNATURE e.^'`� �I-W G"� REGISTERED' Y/ N ' FEE gURREn Address 250 Jasmine Rd.,Casselberry FL 32707 License#.rCAC1814423 � OTHER ROOFER ���, J COMPANv HUG MAC_DONALD/AL.VAREZ ROOFING .$IGNATURE REGISTTEREU I Y/.N. FEE CURREI% r Y/.N Address 10825 Tom Folsom Rd.,Thonotosassa.FL 33592 License# I CCC1329562 REStr)ENTIAL Attach(2)Piot Plans;(2);sets of.Building.Piaris;(1)set of.Energy Forms;R-O=W Permit for new construction. Minimum ten(10)woddng days after:submi ittal.date. Re u.iiced'onsite.Constriction 01ans,Stormwater Plans w/'Silt Fence installed, Sanitary Facilities.&1 dumpster;Site Work Permit for subdivisions/large projects _ COMMERCIAL Attach(2)complete sets of Building Plans phis alife Safety Page;(1)set of,Energy Forms.R-O-W Permitfcr new construction.., . Minimum:ten(10)working;days after submittal date. Required onsite,.ConstrucUon Plans,:Storrnwater Plans wl'Silt Fence instb[IW, SanitaryFacllitles,&'1 dumpster.Site Work Permit far all,nevv projects,Aii:c dmmercial requirements must meet compliance_ SIGN PERMIT Attadh'(2)sets of Engineered:Plans. ` *PROPERTY:SURVEY required-forall NEW:cdnstrucfion. piractionw. Fill out applicatlon,completely. Owner&Contractor sign—back-of application,notarized If over.$2500,a Notice of Comrimencernent is required. (A!C upgrades over$7500) Agenf(for the contractor)or Pointer of Attorney(for the owner)would'be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) :Reroofs if shingles Sewers Service Upgrades A/C 'Fences(Plot(Survey/Footage) briveways=Not over Counter if on public roadways..needs ROW 4 Single .Family Dwelling Plan Review Comments 1. F.F.K.shall..be a minimum of-8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F:B.C. 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5. Driveways regiiire.a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material.. 6. All setbacks shall be rivet. 7:. All property markers shall be uncovered.and marked at time of first inspection_. 8 All'A.D.A.requirements shall be,met: 9: No electric,plumbing;mechMical, or.framing shall.be covered without an-inspection and approval first: 10:.All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): 11. Appliances shall not be installed in a location.where_subiect.to-mechanical.damage unless protected by approved barriers. M3034 of the F.B.0 12. Water heaters'shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C tinits;.shall.be raised at least 3" above f nished grade. M 1308:1_ 14: Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors.are to be installed in accordance with R313:1 of the F.B.C. 16: All glazing requirements are to be in accordance.with R308.4.6f the F.B.C. . . 17. All means.of egress are to be in accordance with RM I of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C: 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all underground plumbing and.electric. 21 All 2016 N.E.C. Codes will be enforced. 21 Tamper-Resistant.Receptacles in accordance with 406.11 of the 2016 N.E. 24. In accordance with the Land Development Code,lots:.shall be sodded before final at least 10 feet around the structure. .25. R403.5.3Hot water pipe insulation. insulation for.hot.water-pipe with-a minimum thermal resistance (R-value) of R-3 shiall.be applied to the followin Piping�1; inch (4.9.1 mm)and larger,in nominal diameter., Piping serving more than:one dwelling unit. Piping located outside the conditioried space.. Piping'from the:water heater to a-distribution manifold.. Piping located under a floor slab: Buried in piping. Supply and return piping ifi recirculation'systems other than demand recirculation systems: 25.Blower door test shall be provided before C.O: 26.A copy of the enemy cacls'shall be with permit at all.times 27. Conn oMal insulation report shalibe provided with permit before final 28.No fence.pool or enclosure':is issued with ahis permit F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6f' Edition' R.O.W.-Right of Way. A.D.A.-.Americans with Disabilities Act. N.E.C.-National Electric Code(2016) 8113=780-0020 City of ZephyrhilIsPermit Applicabort Fax-81 3-780-0021 Building Department Date Received 407 257 MA 'Phone Contact for Permitting ........ 0031=3333M rTT ......... ....T'T owner's Name LINKS AT CALUSA SPRINGS. LLC Owner Phone Number I 407_957-6940 Owner's Address 12301 Lucien Way Ste 260, Maitland FL 3 Owner Phone.Number F_ Fee Simple Titleholder Naive F/A Owner Phone Number Fee Simple Titleholder Address IN/A - J-00 ADDRESS f_G Slie 164 L4 n r1 U A 2ee&h,I Is 1 FL 3 3 S 4 2 LOT# SUBDIVISION IINKS AT CALUSA SPRINGS I PARCEL ID910-4-26-21-026H 0000-069 (OBTAINED FROM PROPERTY TAXNOTICF) WORK PROPOSED NEW CONSTR 8 ADDIALT SIGN OtMOUSH INSTALL REPAIR PROPOSED USE SFR X F__J COMM OTHER I TYPE OF CONSTRUCTION 'BLOCK E3 FRAME STEEL DESCRIPTION OF WORK NEW SINGLE FAMILY HOME Total Sq Ft BUILDING SIZE. f-0TAL Under Roof SO FOOTAGE E= HEIGHT C- JZDBIJILDING $ VALUATION OF TOTAL CONSTRUCTION 1�_�,� IZDELECTRICAL 1$ AMP SERVICE160 PROGRESS ENERGY W.R.E.C. 71 ZIPLUMBING $5,900.00 Z]MECHAN.ICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING SPECIALTY OTHER FINISHED-FLOOR ELEVATIONS FLOOD ZONE AREA =YES X Noti_ HHHHHH!Hl i- 1.!1 H�H I I!,1114 Hill! H BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEEfCURREA LL-Y/W— Address LIc'qnse,# F ELECTRICIAN COMPANY sir.NATURk REGISTERED L FEE CURREN Address License# F CCJJ -1,A 3,�ti crm +L&,,JSeAPe3 ftOMBE* J 9 SIGNATUREASIGNATURECOMPA%Y At 1. REGISTERED I Y N--1 -FEE CURREN LXLN J Address IP-0. GOX 1194,0ov" ,r-L`33 License wi- 2d20 2C MECHANICAL COMPANY SIGNATURE REGISTERED Y-/ N." FEE CURREN L_IL—N J .Address License QTHtRR00FER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN E�_N Address License# H!+HHi1HHH I HiHil RESIDENTIAL Attach Plot Plans,.,(2)sets of Building-Plans;(1)set of.Energy Forms;R.O-W Permit for new construction, Minimum ten(10)working-days after submittal I date. Required'onsite,C66structl6n Plans,Stormwater Plans W1 Silt Fence installed, Sanitary Facilities-&I du m-pster,Site Work Permit for subdiviSlons/large projects COMMERCIAL Attach(2)complete-sets of Building Plan's plus a Life Safety Page;(11)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working-days after submittal date. Required onsite,Construction Plans,Stoirriwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpstet.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGH PERMIT Attach.(2)sets of-Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. .............. N 1. 1 1-14 pp Directions: Fill out application completely. Owner&Contractor sign.back of application,notarized Over$2540,a Notice of COmmeridementis required. (AfC upgrades over$7600) Mentffor the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorising same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sbwers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if an public roadwoys..needs ROW NOTICE"OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions° which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may cited for a misdemeanor violation -under state law. If the owner or.intended contractor are uncertain as to what.licensing.requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division-Licensing Section at 727447- 8009. Furthermore, if the owner has hired a contractor or contractors, he, is advised to have the contractor(q) sign portions of the "contractor Block" of this application for which they will be responsible. If.you, as the owner sign as the contractor, that may be an indication that-he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees.and Recourse Recovery Fees may,apply to the construction of new buildings, change,of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07'and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood-that Transportation Impact Fees and Resource Recovery Fees.must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 71% Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify that .1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",- I certifythat i have obtained a.copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement...•. CONTRACTOR'S/OWNER'S'AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable taws regulating construction, zoning and land development_ Application is hereby made to obtain a permit to do work-and' installation as indicated. 1 certify that no work.or Installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction; County.and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wefis, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks, Navigable Waterways. - Department of Health $ Rehabilitative Sery ces/Environmental Health Unit-Wells, Wastewater Treatment, Septic.Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority=Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone``V°unless expressly permitted. If the fill material is to be used in' Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time.of permitting which is prepared by a professional engineer licensed by the State of Florida. . If the fill material is to:be,used'in Flood Zone "A" in connection with a permitted building using stem wall constructions I certify that.fill will be used only to -fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre which:;aro;blevated by fill,an engineered drainage plan is required. If I am:the:A6ENTfORTHE:dWNER, 1 promise in good faith to inform the-owner of the permitting conditions set forth in this affidavif`;prior to commencing.construction. I understand that a separate permit may be required for electrical work, plumbing;signs;°viieiisr:poo1s, i0r. conditioning, gas, or other installations not'specifically included in the,application. A permit issued shall-be.construed to be a license to proceed with,the..,Work and.not as authority to violate, cancel, alter, or set asiderany provisions;of tFte,.technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring.A%correctionoferrorsin plans,construction or violations of any codes. Every permit issued shall become invalid unless theiwork authorized bysuch permit is commenced within six months_of permit issuance, or if work authorized,by the permifli suspended or abandoned for a period of six(6)months afterthe:time'the work is commenced. An extension may be requested, in writing,.from the Building Official for a period,.not to exceed ninety(90) days and will demonstrate justifiable cause for the`extension:"-If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO.OWNER:- YOUR-:FAILURE TO. RECORD A NOTICE OF-COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE-FORIMPROVEMENTS TO YOUR`PROPERTY.-.IF YOU=INTEND TG OBTAIN FINANCING,CONSULT WITH YOUR!LENDER OR AWATTORNEY BEFORE'RECORDINGYOUR'NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. .03) OWNERAR AGENT CO TO Subscribed and sworn to( r affirm befo me this Subscti�and swo �((o�r affirmed before me this b TAT AS MA RA S TA ES BOWIE CLARK VVffo slare personally known o r has/hdve produced o is/are ersonall known to ti—have produced as identification. IAA as identification. Notary Public Notary Public Commission No. GG 308696 Commission No. GG 308696 Daphne Clark Daphne Clark Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped �APFINE gg 86 o�'gY PU84c Dominion#GG 30 mp,Q o wFAG gg = * Fxpites June 2 $0*0 o4,gYPUB�j�, 2023 m o 11+� _ ' * Eypires3uae2 ry1FOF�oe Bader * o* iPjgrF OF��? )4-26-21-0260-00000-0690 1 Pasco County Property Appraiser https:Hsearch.pascopa.com/parcel.aspx?parcel=2126040260000000690 Parcel ID 04-26-21-0260-00000-0690 (Card: 1 of 1) Classification 00000-Vacant Mailing Address Property Value LINKS AT CALUSA SPRINGS LLC Ag Land $0 2301 LUCIEN WAY STE 260 Land $25,025 MAITLAND, FL 32751 Building $0 Extra Features $0 Physical Address 6828 SHELBY LYNN WAY, ZEPHYRHILLS, FL 33542 Just Value $25,025 Assessed (Non-School Amendment 1) $25,025 Legal Description (First 200 characters) Non-School Taxable Value $25,025 See Plat for this Subdivision School District Taxable Value $25,025 LINKS AT CALUSA SPRINGS PB 81 PG 074 LOT 69 Jurisdiction CITY OF ZEPHYRHILLS Land Detail (Card: 1 of 1) Line ;Use Code _ _Description _ ZoninglUnits ,Type _ Orice _iCondition}Value 1 j 0100V I CP1-1 i SFR OPUD 5,500.00 SF i $6.50 0.70 l $25,025 - ------._.._. -----.._. -....- - - �. .. Additional Land Information Acres Tax Area i FEMA Code Neighborhood Code(s) i ---------- -- - - -- --- -- - --- --- 0.13-- --------------30ZH` -----�----------_-_-----------1•--------- --__._._ LKCS Building Information (Card: 1 of 1) Unimproved Parcel Extra Features (Card: 1 of 1) Linew -_Code iDescription 'Ly ar ;Units Value No Extra Features Sales History Previous Owner: UNITED CAPITAL FUNDING CORP Month/Year ;Book/Page jType ODOR Code ;ConditionAmount 10/2019 I 9987 / 0218 Warranty Deed ' 05 Vacant $2 760 000 ._a 04/2016 I 9350 / 2262 Certificate of Title 12 1 Vacant $0 _..__........_.__.._...__......__.,........__._.._..__..._.___.____...___.__...._._ ...._-__..----___._........................_____._1.__._......_—....-._._.._._ _....._-....__..__.____._.. _........__.-.......__._.._._..-__......_. 12/2011 8639 / 3248 ! Warranty Deed ' 05 1 Vacant $0 _ _._ ._. 11/2011 1 _...._8627 / 0126 ___..-.._l.__....._.Warranty Deed - 1-2.__..____...._ ..__._Vacant-----_._ .`_.. ._. _N...._ ._-- 05/2008 I 7848 / 0427 i Quit Claim Deed i Vacant I $0 05/2008 7836 / 1714 Certificate of Title Vacant $0 I of 1 2/8/2021, 11:30 AM STATE COP`( FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KH02743 Ivanhoe(TAM) Builder Name: K Hovnanian Homes Street: 6828 Shelby Lynn Way Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number. Owner., Jurisdiction: Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type42785.3 sqft.) Insulation Area 2. Single family or multiple family Detached a.Frame-Wood,Exterior R=11.0 1312.00 ft'b.Concrete Block-Int Insul,Exterior R=4.1 1112.20 ft' 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 361.11 ft' 4. Number of Bedrooms 5 d.N/A R= ft' 5. Is this a Worst Case? Yes 11.Ceiling Types (1610.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1610.00 ftz 6. Conditioned floor area above grade(ft2) 2666 b.N/A R= ft' Conditioned floor area below grade(ft') 0 c.N/A R= ft' 7. Windows(211.1 sqft.) Description Area 12.Ducts R ft' a. U-Factor. DbI,U=0.34 109.75 ft' a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 274.3 SHGC: SHGC=0.23 b. U-Factor. Dbl,U=0.34 61.19 W 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.29 a.Central Unit 33.1 SEER:15.00 c. U-Factor. Dbl,U=0.63 40.20 ft' SHGC: SHGC=0.32 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 1.000 ft. a.Electric Heat Pump 32.6 HSPF:8.50 Area Weighted Average SHGC: 0,265 8. Skylights Area c. U-Factor:(AVG) N/A ft' 15.Hot water systems SHGC(AVG): N/A a.Electric Cap:50 gallons 9. Floor Types (2666.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1131.00 ft' b. Conservation features b.Floor Over Other Space R=0.0 1066.00 ft' None c.other(see details) R= 479.00 ft' 16.Credits Pstat Glass/Floor Area: 0.079 PASS Total Proposed Modified Loads: 80.93 P q S�+ Total Baseline Loads: 80.61 I hereby certify that the plans and specifications covered by Review of the plans and O�R4B sr`fTA this calculation are in compliance with the Florida Energy specifications covered by this0Vs Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: .A/6y Before construction is completed DATE: 2-1-9 2rz this building will be inspected for 0 !` a compliance with Section 553.908 * ° � I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: SGWa.L 1Zvverctw BUILDING OFFICIAL: DATE: 2/8/2021 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.60 ACH50(R402A.1.2). 1/25/2021 1:45 PM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5 DESCRIPTION:LOT69, PLOT PLAN (NOT A SURVEY) 0 LINKS AT CALUSA SPRINGS, a AS RECORDED IN PLAT BOOK 81, BASIS OF BEARINGS: PAGES 74-79,OF THE PUBLIC RECORDS CIL OF RIW OF SHELBY LYNN WAY OF PASCO COUNTY,FLORIDA. BEARS N.02°03'37"E.PER PLAT, THE PROPERTY DESCRIBED HEREON IS LOCATED IN FLOOD ZONE W PER FLOOD INSURANCE RATE MAP NUMBER 12101 C 0289F,EFFECTIVE DATE SEPTEMBER 26,2014,COMMUNITY No.120235 PANEL 0289 F. I o LOT 70CD I I CD S.87°56'23"E. 110.00kr5 Q1 22.531 42.0 05'SideSetback —� z q O 15.00, Je "13, 52.00' O PAD.U.E.IN y1 41 o j �-' LLo I I g I £ O c� Ia 1 n 1L I O --' �rL 22.531 S.0' 16E18 I } ¢ LLJ 1 a . a Proposed House 1 LD 2 c , �e =J Planlvanhae-A I I r W j l o M 25.2 1 5.3' Garage-t[anal o g 10.0' 35.47 I— X q M I II z v v1rnPro Fluor Ele 103.84'per Un Pm-dGradingPla I-- o. .n 35.47' i N ~ I Slab an LOT 69 Grade 1 O Construction —Pmpased— I (n 25.29' 39.3' �A/C I �I I o N. 7°56' 32 W. 110.00' o Ui o � I LOT 68 LEGEND: =AxarmPFsof on— µ •PoWuss7JJ PJ10.IIE•PwVATE ACfE O=NINE " lR9NA4a weSR0rrPHW15EN01m1 OiLLNYPASEYENr AIEaPJA'AOEa PLH10 19'O/EtlAA1E0 GA- f01Rb RNLP0AD 6wIQ PAEP•PFA TYUNeJ6OEWHKRAn PwN•uE—,aebN RIS& OA.grVµp,00. PA=PPOPE0.IVYNE ®=NOm@EAPIND NaA•XOMEDNNFASASSOCU110r1 PA;=PLlWIr1J1 PJ¢oRmE mR•<fA1Hm mPo1FHRKOws J[IPE•wN OENSIIYP¢YETNriB1E (RI'R/tlw. m0•oourJuraJroEeaoJaEJrt wPE —usrca o•oENnFlrwnnV Ra.Rexfwrm cOxmETEPPE a•onrm Ia.u�JsneusxEss Rm=REssTmm O•NfeDAET rq.r,.Jey/.{ PIW=RGNi4 WAV •WATERNEI63 DP•—c..TPOIE 15.11 F1JEE➢suRVEYOR fsl•aNM1M ® .WATE MVE OYP•WNNMIE➢NETKRFE YEe•WTN EMe11NOGW0E SEC=SECIbN mc•mxWEtE N•uANxalE iWP=IOVMSMP FlflEHMRANr T•erfV o<TWJPA INRI•NONRILaIL RGE=RANGE GL=CEH—NE NAw•NmJHNJEJNVN en=S—Rannu, RAMAGEEAS .T �.HUa aTA4X 6Er DE=D VEAIIGY MTW IW ..Is DAAE•a.—wUACG55 xow•runmu GEmETrc sJw=s:rxAA aoisxJaJeo ♦•IATH SET FAEeIENr WinV• —1BJ9 9"f=EET PARI(ERWLm NIA DYE•G0.NNApEArAMG0.ER&EGf✓ESS MeNOTi o SCIIE ASFR.➢.EWnfWEST R00.OAWAte1 •Ilr14J1'PolE FASaIEM �.�tlNRECORps YAWfL@Ja@MSJwR Deu•DRAxwEArmuJUTr ErovnnrJwEs Tau-- -AWN p--AppppyIDOPIc— WSE.I" •EIEV.(PACE E➢NC FMN—.T.f0.0TELJbN UILIIY WADRNNNJE 4S90N OFHl15a0RNGH PAGJOP•PERN ➢GRAaWO MGRESSENESSEASENEHr AAna—a—aRN! UE=URIrYEcon—i E91T=EA.— .-�To WL=WNNE$$[c. re'-f—D ONVCRETENCMNBR PoMi OF WIEPSECfbN IWB=WETJAwICO.YEERVAnm Je'•WJJONOH PPE POMOFNRVATURE EAREYFM`a Pm PoVROFOGNPNmC1Nl£ WCI5.•WEIWA ca+ssavAnav Fw=j('imwlRN Pm,m 1NJ PCP.PEPNMrENT[ONIR4 M{YT ARFAEE'R.LAIINE DV¢E on1EMlI6E x0THl1 grC.PoMOFRE4E0.'E NR4E NF=NUNF➢ILE RD•FNw P09•POMOf NEtlNNMG WIDE+WALLIAws[MEµn aLFJER fef•PoLW PA0.NE14 NAA p00.JpWr OFCWNFNGeIEM EASeJEM FJ3F.WF.CGE•ROROANwEPJaJ wW•PaWANmTRFEFAmCENOMMEM fPEEXWAIERFlENmWISVON Re•PNOFFSSIONKLVbeURNEYm mrJSEINA1bN EAENEM p4l.MOFESLON/1 SURVEYORaYWPai NO TREES per approved a Drainage SOD AND CONCRETE CALCS Flow PAVING,GRADING AND DRAINAGE PLAN-B. � �^r--= Total Sod Area in Arrow N Total Lot Area in Square Feet t NV Total R Sod Total Conc.Walk Sidewalks&Gutters per approved cSquare Feet is (Includes right-of-way,area between Square Feel t Square Feet 3 N PAVING,GRADING AND DRAINAGE PLAN-B. property line and back or Curb) Datum Conversion 5500 3162 NIA 279 i NGVD 1929-0.84'= (NAVD 1988). Total Conc.Driveway Total Conc.Apron Total RM Walk A/C Pad percent rcc nt Proposed Lot VERTICAL DATUM NOTE: IIII IIIIIIII on Square Feel t Square Feel t Square Feet* Square LotFeet x Coverage Gr(PAGP)pe THE ELEVATIONS REFERENCED TO SHOWN HEREON929 IIIIOIuI�IIuIIIIIIIWIIII IIIIIIIPIIIII�llllllllllllllllllllluulllllllll m 291 N/A NIA 9 1 29% 1 Bm zole 22111010 R, This Sketch Prepared For :K.Hovnanian Homes N q U REVISIONS Digitally signed o a Description Date Dwn. Ck'd I Order No. opt P- Fpo s a revised house model 1/22/21 CRZ 22111010 ca � Scott R N Q' h cenPicare .: . D rp. / Ffo ler o a FLOM E iz ' e'P te: 2021.01.25 Engineering&Surveying Corporation Fa I °`A"°5 7:29:50 -05'00'a 8515 Palm River Road Tampa,Florida 33619 a DATE or (813)621-7841 (813)564-1832(fax) M Client No:2018 SCOTT R. FOWLER SIGNATURE www.lesc.com L.B.#3913 Drawn:TJW DEC.01,2020 a o 1 Checked: FLORIDA REGISTERED LAND SURVEYOR NO. 5185 3 Original No.: 22028455 lCurrent No.:22111010 I Survey Date: NIA Sec.: 4 Twp.: 26 S Rge.: 21 E