HomeMy WebLinkAbout21-1522 Q
r�uninn City of Zephyrhills PERMIT NUMBER
.:r• �, 5335 Eighth Street
Zephyrhills, FL 33542 BNR-001522-2021
Phone: (813)780-0020
Fax: (813)780-0021 Issue Date: 03/02/2021
s ,
Permit Type: Building New (Residential)
Property Number Street Address
04 26 21 0120 00000 0280 1 6292 Bradford Woods Drive
Owner Information Permit Information Contractor Information
Name: PULTE HOME COMPANY LLC Permit Type:Building New(Residential) Contractor: PULTE HOME COMPANY
Class of Work:SFR Construct LLC
Address: 2662 Falkenburg S Rd Building Valuation:$127,176.00
RIVERVIEW,FL 33578 Electrical Valuation:$5,689.00
Phone: (813)964-5182 Mechanical Valuation:$4,745.00
Plumbing Valuation:$5,147.00
Total Valuation:$142,757.00 /J
Total Fees:$14,109.86
Amount Paid:$14,109.86 I
Date Paid:3/2/2021 8:48:14AM
Project Description
CONSTRUCT SNGLE FAMILY 2,892 OAKS OF PASCO
Application Fees
3/4 Water Meter Fee(Calc) $473.78 Irrigation 3/4 Meter(Calc) $473.78
Public Safety Impact Fee-Police $254.00 Electrical Plan Review Fee $34.22
School Impact Fee $8,328.00 SIF 1 percent Fee $83.28
Building Permit Fee $665.88 Address Fee $30.00
Plumbing Permit Fee $65.74 Building Plan Review Fee. $332.94
Public Safety Impact Fee-Admin $26.35 Mechanical Plan'Review Fee $31.86
Plumbing Plan Review Fee $32.87 Mechanical Permit.Fee $63.72
Water Connection Residential Fee $1,010.00 Sewer Connection Residential Fee $2,090.00
Driveway Fee $45.00 Electrical Permit Fee $68.44
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
4L-"rn
ON C OR SIGNATURE PE IT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
INVOICEoo0o . •
FORCITYOF
BILLING CONTACT
JODY SALTER
PULTE HOME COMPANY LLC
2662 FALKENBURG S RD
RIVERVIEW, FL 33578
INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION
INV-00002692 1 02/22/2021 02/22/2021 Due NONE
REFERENCE NUMBER FEE NAME TOTAL
BNR-001522-2021 3/4 Water Meter Fee(Calc) $473.78
Address Fee $30.00
Building Permit Fee $665.88
Building Plan Review Fee $332.94
Driveway Fee $45.00
Electrical Permit Fee $68.44
Electrical Plan Review Fee $34.22
Irrigation 3/4 Meter(Calc) $473.78
Mechanical Permit Fee $63.72
Mechanical Plan Review Fee $31.86
Plumbing Permit Fee $65.74
Plumbing Plan Review Fee $32.87
Public Safety Impact Fee-Admin $26.35
Public Safety Impact Fee-Police $254.00
School Impact Fee $8,328.00
Sewer Connection Residential Fee $2,090.00
SIF 1 percent Fee $83.28
Water Connection Residential Fee $1,010.00
6292 Bradford Woods Drive Zephyrhills, FL 33542 SUB TOTAL $14,109.86
REMITTANCE INFORMATION TOTAL $14,109.86
City of Zephyrhills
5335 8th Street
Zephyrhills, FL 33542
February 22,2021 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1
Building Department
ate Received '� �� - /v� JPhone Contactfor Permitting . ) q _- +I'J ( jam.
�Irtrtr e-ate-® - _
/I l
wner's Name �o c ���'U(l1 C N fA x'0`1 c. (,L Owner Phone Number
r
J
wner'sAddress ��G�Z S' �GLlilb(ttG �l ' iV��bll2�t� L Owner Phone Number �r
m Simple Titleholder Name /A Owner Phone Number
m Simple Titleholder Address I A
)B ADDRESS Lh /S �v LOT# D �
UBDIVISION DOA-'SO VMCIP PARCEL ID# v Z/— — 2/ - 01 219-00000-0,R90
(OBTAINED FROM PROPERTY TAX NOTICE)
FORK PROPOSED a NEW CONSTR 8 ADD/ALT SIGN Q DEMOLISH
INSTALL REPAIR
ROPOSED USE ® SFR. F__J COMM OTHER
YPE OF CONSTRUCTION 'EJ BLOCK 0 FRAME 'STEEL [�
ESCRIPTION OF WORK
UILDING SIZE SQ FOOTAGE �1" p�1~ HEIGHT01hD-
=BUILDING VALUATION OF TOTAL CONSTRUCTION
s. (�
=ELECTRICAL Is 6 U q ,10 AMP SERVICE PROGRESS ENERGY W.R.E.C.
=PLUMBING Is /qn/00 J
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS = ROOFING SPECIALTY OTHER
'INISHED FLOOR ELEVATIONS al q n / FLOOD ZONE AREA OYES NO
MILDER COMPANY a'fc (.
iGNATURE REGISTERED Y/ N FEE CURREN p, Y/N
Address 0��9i t�G� /id�+crC' l(/�/�/eC[)I�Li33J�� Licensse#
ELECTRICIAN COMPANY cJkazla U et/_I a"l G
)IGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 1 , h [CG 7!- tV v 7) Q/rp L License# EC 1 3 00 7 5
DILUMBER COMPANY
5)GNATURE REGISTERED Y 1 N FEE CURREN
Address 3/33/l/:r 2i Imo' �j r�Lc ,FL�✓LJr License# I I`?a7_:�7_7
WECHANICAL COMPANY /1)4C/7pS /fw (b-'VU�/•<<
31GNATURE REGISTERED Y/ N FEE CURREN L Y./N
�(/3 I�GrLt67 1 fiZ1f� dSLY►,�L 3c/(P(a� License / 3 Address
DTHER COMPANY
/ did PCIQJ fi
SIGNATURE REGISTERED L_ILLN J FEE CURREN
Y/N
Address ���/n �f ' "�R, License# 6/3-�F g�
tleA088 :0eeotl :e.tlaaaetltlatlaeatlegltlteAe99eunlltleaol< etleeea � oeQEYeflCetleeflanen
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed.-
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a.Life Safety Page;(1)set of Energy Fonns.R O-W Permit for new construction.
Minimum ten'(10)working days after submittal date. Required-onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster..Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
*""PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application, notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
O
i
{
Single Family Dwelling
Plan Review Comments
1. FF.E; shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to cortiply with R401.3 of the F.B.C.
3: Compaction test required if 24" or more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5: Driveways require.a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
1. All property markers sliall be uncovered.and marked at time of first inspection.
8: All A.D.A.-requirements shall be met:
9. No electric, plumbing,-mechanical, or framing shall be covered without an inspection.and
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C. (Fite Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303 A of the F.B.0
12. Water=heaters shall comply with section P607.3 of the E.B.C:
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1
14. Return air in.all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance withF.B.C.R313.1 of the F.
16:All glazing requirements are to be in accordance with R308.4 of the RB:C.
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C.
19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage. They shall be-installed in accordance with the F.B.C:
21. All,plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all
underground plumbing and electric.
22. All 2016 N.E.C. Codes will be enforced:
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C
24. In accordance with the Land Development Code,lots.shall be sodded before final at least 10
feet around the structure:
25: R403.5.3Hot water pipe insulation.
Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the
following:
Piping 31:inch (1.9:1 mm)and larger in nominal diameter..
Piping serving more than.one dwelling unit.
Piping located outside'the conditioned space.
Piping from the water heaterto a distribution manifold:.
Piping located under a floor slab:
Buried in piping,
Supply and return piping in recirculation systems other than demand recirculation systems.
25. Blower door test shall be provided before C.O.
26.A copy of the energy cacls shall be with'permit at all times
27. Copu of fnahinsulation report shafl be provided with permit before rna'
28.No fence,Pool or screen enclosure :is issued with:this.permit
F.F.E.-Finished Floor Elevation
F.B.C-,Florida Building Code 6t'Edition
R.O.W.-Right of Way
A.D.A.-.Americans with Disabilities Act N.E.C.-National Electric.Code(2016)
w
PASCO COUNTY, FLORIDA,
4
? Permit No.
Date Permitted
Builder Name/Owner Name _Pit/k 9-4te's ControW
County Parcel No. -t `fi 76OZ& SubDly: 6akj
Address/Location !i S
ClasslflcatlonlType of Usq
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z
Exempt ❑'Yes E] No How Determined
Impact Fee-Amount $. Zone No. TAM
SCHOOL'IMPACT'F— EE
I Account (056) Single-family Detached House Amount $ � L
i (057) Mobile Home
i (056) Other Residential
123) Collection Fee
Exempt Yes..❑No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $
Exempt ❑Yes ❑'No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑Yes ❑-No How Determined Total Amount
z
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Chocked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL.THE TOTAL AMO' t.j S LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY
Ack owtedgement below does not Imply acceptance of concurrence,but simply recelpt of a copy of We form,placing
the building permit owner on notice of this assessment and the conditions of payment for some.
DATE RECEIVED BY ;s
RECEIPT NO. DATE BY
Building Department
Date Received Phone Contact for Permitting
FlUalt7fa G £ T x+ - 3= a Q a. s. aul, ar u"U -.aE PE
,:f J , „ /l ,, i3
Owner's Name f. �1 , .• Owner Phone Number -
Owner's Address J ' L Owner Phone Number
Fee Simple Titleholder Name IVIA Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 71 �r l� _Z_ � J , LOT#
SUBDIVISION I .� fj: � PARCEL ID#
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED B NEW CONSTR H
ADD/ALT SIGN [� DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR COMMA OTHER / l fj)j
TYPE OF CONSTRUCTION nBLOCK (FRAME STEEL
DESCRIPTION OF WORKf
BUILDING SIZE I O'X l # SQ FOOTAGE HEIGHT.
MAW_IL W.If IL T.FE M_E _ -z UL C&W_i� R4L sk €
BUILDING VALUATION OF TOTAL CONSTRUCTION
ELECTRICALCo AMP SERVICE PROGRESS ENERGY Q W.R.E.C.
PLUMBING
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
GAS Q ROOFING 0 SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS 41,q7 FLOOD ZONE AREA =YES NO
BUILDER COMPANY ti
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License#
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License#
PLUMBER COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address I License#
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address �) ) License#
OTHER COMPANY V// �I(�` il �. 17�G!{J D� IG�GLi.�%L��/GIi
SIGNATURE REGISTERED Y/N FEE CURREN Y/N —�
Address / ka� License#
(1 � 8tiDA.999aI.ga0 Ga% Lria�l '� � � i 60 � R SOtt � � �z� Ott � � ttR:� z � � � 5 >& � 0� 11@ir �� :f� utf ® iJ
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W:Permit for new construction,
Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms. R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
ouuuuiy vepaiunent
NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive
than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they
may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and
contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Lic$nsing Section at 727-847-8009.
Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this
application for which they will be responsible.If you,as the owner sign as the contractor,that may'be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or
expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that
such fees,as may be due,will be identified at the time of permitting.It is further understood that-Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a"certificate of occupancy"or final power release:If the projA-Act does not involve a certificate of occupancy or final
power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant,
have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of
Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as
indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.1 also certify that I
understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I
must take to be in compliance.Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or
other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with,the work and not as
authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a
period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to
exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered
abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
FLORIDA JURAT(F.S. 117.03)
OWNER OR AGENT CONTRACTOR
Subscribed and swo t--o``or affirmed)bipfore me this Subscribed and sworn_ r affirmed)be re this r
5� 7�2 7 /2 _by /�2d./a L. II .1/1DIOS� Z�by t�� LL—
WWh are personally known to me or has/have produced Who is/ar personally known to ma or has/have produced
as identification. as identification.
Notary Public Notary Public
Comm' 'o No. (� 3 S/ 7/ Commission
LL
Namef of Notary typed,printed or stamped Name of NdtarylVped,printed or stamped
PATRIOIA OUROHM- PATRICIA OURCHEtT
= o MY COMMISSION#GG365171 4(, W COMMISSION#GG365171
EXPIRES:AUG 13,2023 EXPIRES:bUG 13,2023
a Bonded through 1st State Insutance Bonded through 1st State Insurance
CITY OF ZEPHYRHILLS'
66cify Of Pura Water"
5335 Eighth Street°Zephyrhills,Florida 33542-4312
(813)780-0000-Fax(813) 780-0005
GENE WHITFIELD Mayor June 13, 2018
Mr.David Waronker
CITY COUNCIL 1420 Celebration Blvd., Suite 200
LANCE A.SMITH Celebration,FL 34747
Council President
Dear Mr.Waronker,
KENNEM M.BURGESS,JF-
VicePresident City of Zephyrhills Ordinance 1003-08, Section 12, Paragraph 5, provides that
planned unit developments (PUD) approved prior to September 30, 1988 are
CHARLES E.PROCTOR exempt from paying transportation impact fees unless amended to permit
additional development that would generate traffic.
W.ALAN KNIGHT
The Silver Oaks PUD was approved on its third and final reading on January 11,
JODI WILKESON 1988, and therefore is exempt from paying transportation impact fees as stipulated
in Ordinance 100308 provided the original permitted number of dwelling units
remains the same. According to Todd Vande Berg,city planner,those numbers
within the Silver Oaks PUD have remained constant.
STEVEN F.SPINA
City Manager
Therefore,the Oaks at Pasco is exempt from paying these fees. A copy of
LORI L.HILLMAN Ordinance 1003-08-is provided for your information. The exemption and credits
City Clerk,CMC section is located on page 10.
MATMW E.MAGGARD Sincerely,
City Attorney
Steven F, Spina,PhD
City Manager
cc: Todd Vande Berg, City Planner
Bill Burgess,Building Official
Matthew E. Maggard, City Attorney
p-7
._,......_._.� �.. _.._
D�-7 i ! 1
+ 25 I i 26 27 I I �- - 9- yi, f4 30 ► 31
7S L
I 8g.10 TV 89.20 T14. 89.35
r w 82, W
fAfIOi+IS FER :-
,,`
I ram"'
PLOT PLAN
DESCRIPTICIN:(AS FURNISHED)
LOT 28, OAKS OF PASCO
AS RECORDED IN PLAT BOOK 80, PAGE(S) 113-118, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
ON LOT CALCULATIONS
LOT = 5,750 SQ. FT.
LIVING AREA = 2,196 SO. FT.
GARAGE = 615 SQ. FT.
ENTRY = 34 SQ. FT.
LANAI = 260 SO. FT.
PATIO = 0 SO. FT.
DRIVEWAY = 347 SQ. FT.
A/C PAD = 9 SQ. FT.
WALKWAY = 32 SO. FT.
IMPERVIOUS = 61%
= 3493 SQ. FT.
SOD = 2,257 SQ. FT.
OFF LOT CALCULATIONS
RIGHT OF WAY = 394 SQ. FT.
DRIVE APRON = 57 SO. FT.
PUBLIC S/W = 250 SO. FT. 1" = 30'
SOD = 87 SQ. FT. MQ�SCALE
TOTALS 0 15 30
AREA = 6,144 SO. FT.
DRIVEWAY = 404 SQ. FT.
SIDEWALK = 282 SO. FT.
SOD = 2,344 SQ. FT.
0
GO
04
i6PS82*53.12 E OaFLOOD ZONE "AE"
gi 20.00, _j
S82
0
'53sl2"E
211.7' t6 115.00s
1 0
UD
5
D&AE"
66.0,
Oa , o
0�_ z 76,00,
0 cq craf
Lu
• B.O.
,
C.)
4110 0 I
p
j: 10
0 a5NI 0 'cv
b
co
LL_ SO tie
c) 6.0. Do It:tu
uj
00 _j
-q-
0 10 2d,91
ca
b zo
WI T
64.01
.0
-c
A/C
1
PREPARED FOR: '�tr N82*53'12 W 115. 0 27.3
00
p^1v FLOOD ZONE "X"
cli
0
APPROXIMATE 100 YEAR FLOOD
C) ELEVATION LINE PER FEMA FLOOD ZONE "AE"
BUILDING SETBACKS
FRONT- 20'
REAR: 10,
SIDE: 5'
SIDE STREET: 15'
NOTES:
1. PROPOSED ELEVATIONS SHOWN HEREON ARE BASED
ON THE APPROVED ENGINEERING PLANS PREPARED LEGEND:
BY CORNELISON ENGINEERING & DESIGN INC.
2. ELEVATIONS ARE BASED ON NAVD 1988 BUILDING SETBACK LINE PI POINT OF INTERSECTION
DATUM. PC POINT OF CURVATURE
1 FOR ALL LOTS WHERE SIDE—YARD CENTERUNE PT POINT OF TANGENCY
SETBACKS ARE LESS THAN 7.50 FEET, A RIGHT OF WAY LINE RP RADIUS POINT
MINIMUM 5.00 FOOT WIDE DRAINAGE AND PRC POINT OF REVERSE CURVATURE
PROPOSED ELEVATION POP PERMANENT CONTROL POINT
ACCESS EASEMENT IS REQUIRED PER PASCO TYP TYPICAL
COUNTY LAND DEVELOPMENT CODE. PROPOSED DRAINAGE FLOW CS CONCRETE SLAB
(P) PER PLAT
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (C) CALCULATED
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PB PLAT BOOK
THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PAGES
OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/w SIDEWALK SO. FT. SQUARE FEET
DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY D+AE F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
F.I.R.M. FLOOD ANCE RATE MAP
CONSTRUCTION. NAVD NORTH INSUR AMERICAN VERTICAL DATUM
SANITY SEWER
THIS IS NOT A SURVEY DESSE DRAINAGE EASEMENTEASEMENT
THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT
FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M. MAP NO. 121UIC0452F SURVEYOR NOTES:
DATED 09/26/2014 AND FOUND THE SUBJECT PROPERTY APPEARS TO UE 1. THE SURVEYOR HAS NOT ABSTRACTED THE
PARTIALLY IN ZONE "X- &-AE-. ZONE-X-, AREAS DETERMINED TO BE LAND SHOWN HEREON FOR EASEMENTS, RIGHT
OUTSIDE THE 0.2%ANNUAL CHANCE FLOODPLAIN. ZONE*AE" AREAS
DETERMINED TO BE SPECIAL FLOOD HAZARD AREAS SUBJECT Y6 OF WAY, RESTRICTIONS OF RECORD WHICH
INUNDATION BY THE 1Z ANNUAL CHANCE FLOOD EVENT, WE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND.
ELEVATIONS DETERMINED TO BE 88.5'. THE SURVEYOR MAKES NO
GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
LOCAL F.E.M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN.
BEARING BASIS:
BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF A5M 3. NOT VALID WITHOUT THE AUTHENTIC
BRADFORD WOODS DRIVE BEING N07*06'48"E, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTICELECTRONIC SEAL OF A FLORIDA LICENSED
REVISED: M I—= F;Z I CAN SURVEYOR AND MAPPER.
(FIELD DATE:) 43 U F:;,'\/I—=N'I r-J C�- Digitallysigned by James W Boleman
• DN;�US,53=Florida,I=Orlando,
SCALE: 1" = 30 FEET o-AMERICAN SURVEYING&MAPPING,
Sc MAPPING INC.
APPROVED BY: J13
com CER71FICATI0N OF AUTHORIZATION NUMBER LB#6393 FOR
3191 MAGUIRE BOULEVARD, SUITE 200 F '-Date:2021.01.04 7610:24-05,00, THE
JOB NO. —191105 LOT 28 ORLANDO, FLORIDA 32803 Adobe Acrobat version:11.0.23 FIRM
(407) 426-7979
DRAWN BY. DSB PLOT PLAN 12/30/2020 JG WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE
L_