HomeMy WebLinkAbout21-1535 1 4 .Q. FIUIItOf_Iry City Of Zephyrhilis PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BAR-001635-2021 Phone: (813)780-0020 Issue Date: 03/01/2021 Fax: (813)780-0021 Permit Type: Add/Alter (Residential) Property Number Street Address 04 26 210070 00100 0020 6378 Silverado Ranch Boulevard Owner Information Permit Information Contractor Information Name: D R HORTON INC Permit Type:Add/Alter(Residential) Contractor: D R HORTON INC Class of Work:Add/Alter Residential Address: 6378 Silverado Ranch Blvd Building Valuation:$2,000.00 ZEPHYRHILLS,FL 33541 Electrical Valuation:$1.00 Phone: (813)549-1968 Mechanical Valuation:$1.00 Plumbing Valuation:$1.00 Total Valuation:$2,003.00 Total Fees:$142.50 p /✓��� Amount Paid:$142.50 Date Paid:3/1/2021 12:28:23PM Project Description REMOVE SALES OFFICE CONVERT TO GARAGE BP#17936 Application Fees Building Permit Fee $50.00 Building Plan Review Fee $25.00 Plumbing Permit Fee $45.00 Plumbing Plan Review Fee $22.50 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner:Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER QtVDf7eohY[hU\s Permit Anp\\CatiOD Fsx-813-780-0021 ` . Building Department ' Date Received IC Owner's Name Owner Phone Numl 3�L Owner Phone Number -Fee Simple Titleholder Name -s-rl w_ Owner PhPne Number Fee Simple Titleholder Address JOB ADDRESS o6 LOT# (OBTAINED FROM P ROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE ' SFR 'COMM OTHER DESCRIPTION u,WORK BUILDING SIZE =BUILDING VALUATION OF TOTAL CONSTRUCTION �--�E��C�R\CAL AMP �--1 p �-� ___' . 0AA Id q ����—\PLU rw �-_� =�KiG �pn~ .�� � ~ =mECMANIcAL MECHANICAL INSTALLATION '[--�GAS 1:2RDOFNG F1 ' SPEC|8�`� | | OTHER7r ' /Soo F(N\SHEDFLOORELE\A\TONG FLOOD ZONE AREA [__]YES No ' ="/L"Em C"='=`' SIGNATURE eco\orsneo L_l/_N_J rEP:c«mRE^ L_Y/NL_| Address License# ELECTRICIAN >RLCOMPANY SIGNATURE nEo/aTsnso L_11�L_] resouRneN L_l7 N_� Address PLUMBER � SIGNATURE '^ Address MECHANICAL COMPANY SIGNATURE �2 Address OTHER COMPANY SIGNATURE REGISTERED -.Y1 ' Address u x x 11 1 x x u m 1 u x n m m x x u x x x x `u x u x x-m I x I I K I x u 1 101,10 N 1 1 x 1 x 1 1 1 1 w x x K RESIDENTIAL Attach Cq Plot Plans; sets of Building Plans;(,I)set of Energy Forms;R'0-W Permit for new construction, ` Minimum ten(1V)working days after submittal date. Required onsite.Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Pergilt for subdivlsions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms,R-O-W Permit for new Construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities Q1dumostar.Site Work Permit for all new projects.All commercial requ|m�nantsmuetmoe6com�ianno SIGN PERMIT /�avh�� �� sof Engineered P|�ns. ' ~°°°PROPERTY SURVEY required for m\|^NEYVconstruction. - Fill out application completely. � Owner&Ounhacior sign back of application,notarized If over*usun^a Notice qfCommencement is required. (Vc upgrades over$75OO) � Agent(for the contractor)or Power of me�(for the owner)would bo someone with notarized letter from owner autho in sama O�ER THE COUNTER PERMITTING (copy ofcunhant�qu(md) Remofs if shingles Sewers Service Upgrades A/C Fonpes(P|ot/Sumey/Footag' Orha,aaym-Not over Counter ifnn public madvaym'ooe4aROW � . NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions.• UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as.required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County.Building Inspection Division—Licensing.Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have thb contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly.licensed and is not entitled to permitting privileges in Pasco County. 'TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees'and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power•release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must'be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): if valuation of work is $2,600.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is ,.my responsibility to identify what actions I must take to be in compliance. Such agencies include,but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells', Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage• plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by-the State of Florida. If the fill'material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter., or set aside any-provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a-correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the.-work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER,OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT - --- __ FLORID/_,1.URAT_(F.S,-117.03) - - --- OWNER OR AGENT �=�� CONTRACTOR Subscribed and sworn to(or affir d)befor me this Subscribed and sworn to(or affirmed)before me this by �f1t`- UI.r•g1 o by Who is/are personally known tome or has/have prodbued Who is/are personally known to me or has/have produced as Identification. as identification. b Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed of stamped Name of Notary typed,printed or stamped Notary Publlo State �Fl_d.EPPAL Mlah®Ile MoyesMy Commla9lon HH t397 Explrea 12/21/2024 SQ.FT. CALC. S A ■ CH I T E C Ti ' 110 LIVING 1828 SQ.FT. I'-4 ii '-4GARAGE 430$a FT. 12'8' IS'-0` 9'-b' ENTRY IS SQ.FT. 3'-4' Ib'_0• 101_0° LANAI 88 SQ.FT. TOTAL 2362 5Q FT. Dpc,#jn (2)30S2-S4-4 G EGESS R (2)3052-SH ---------- 441 N.RONALD REAGAN BLVD. LONGWOOD,FL 32750 I PH:407-7746078 FAX 407-7744078 R'OO 8 4NGLG ip 0 www.abdesi�group.com IID' I m AA#:0003325 EXTERIOR MASONRY 01SYUNITES WALL BRG.HEIGHTS 8'-8'GLG. 6068 BGD. ® h x8 DINING e 'a I _ a'-a'cLG. 8-0' 4'-8 r-' 8'2 4'-8' l-5' b-II° in ! iiiiii ,. I O v 2'-4 n Irc HITCHEN I 4 SHWR AN I • • 0 0 - IR-ISH ING �q b I REF I [LIII A � I i I I I ti" l ' a'-B'CLG. MT. a SVHDIV. ae MT: m O SILVERADO = wH. r 22'x84' 1 .0 -, LOT 2 I ACCESS I BLK 1 I /ccND)I i ii PROJECT ? ['..- J� BOLLARD 4' 3-8' _ V. b 8' 3-4" 04128.00-02012 v AS REa a =uj c `� ATH 2 m3 s ARCH MODE a REVIEw DAT Es 2102 m CODE LDG. s QI I a 8B B'CLG �J 4EBB PLAN QTY of �pHYF�M� "1828-CALI" EXAMINER LS G a GARAdE S�rnra: OPT.LOCATION- m I0 LEFT EXPRESS HOMES FOYER- — I pAa REPRESENTATIVE 8'-8'CLG. 0 BDRM•#2 TO FIELD VERIFY 3068 W) a-B°CLG' e 0 FLOG R 36'X10'TRANS. `n - LINTEL B 1'-B' PLAN ENTRY �1 AFP. 8-S L . 'n I pF��L LI ?8 * 77 150 MPH EXP. B I6'-0X --- 1 i0(2)3082-SW ___ T OP�� rOfE b'plpHp(y� IEIl1R(B ' '1'-0X1' I EGRESS ll A FOOTl1(£ I MIN.WINDOW ----------------- ST OF A CRITERIA 10 5 25/-33 0 28' II-4' EXTERIOR SWING IS 5 24/-31 2'-8' 16'-0' 2'-S' 2'- 2'-2' 1'-0' 1'-0' DR MIN.CRITERIA 21'-4' 4'-4' 14'-0' CRITERIA 41 5 a2/-28 35' 5' 3 '-S' _ 16010 O.H.D. 112 5 2V-25 B ro A. BASIC WIND SPEED MPH = 150 (Vu1t) INTERNAL AR PRESSURE COEFFICENT = t 0.18 BLDG. CAT.=II, NOTE: -2-8 LOUV.DOOR W/AIR HANDLER ON METAL STAND OR 2-8 SOLID EXP-=B, MEAN ROOF HT. = 15'-0" DOOR W/RETURN PLENUM AND RETURN AIR GRILLE. 2-12-_1 -VERIFY CONDENSER PAD LOCATION WITH SITE PLAN. SCALE 1/4"=1'-0" PRESSURES HAVE BEEN MODIFIED PER SECTION 612.2 -FRONT DOOR ASSEMBLY TO BE THER IA-TRU FIBERGLASS DOOR A D( LI THE E FBCR 5TH ED. (2014) TO MEET TESTED W/TRANSOM(SINGLE ASSEMBLY) /E��tiles\.C 11 SHEER' ALLOWABLE OR NOMINAL HE LOAD VALUES FROM T -20 MIN.FIRE RATED DOOR FROM GARAGE TO RESIDENCE TO BE PRODUCT MANUFACTURER.COIIIPq.DATE071. EQUIPPED W/SELF-CLOBING DEVICE(R302.5.0 FBCR 5TH ED.(2014). • STD. CALC5 - OFF-RIDGE VENTS ONL1 A R C N 1 T E C T E AREAOFATTIC = 2364$Q FT. 1NET FREE VENTILATION AREA REQUIRED = 2/100 REQUIRED VENTILATION AREA = 2364/300 7.88 VENTILATION AREARSO.INCHES PER FT.(144) = 1134.72 SO.IN. MN.REQUIRED VENTLATION = .5X 1134.72 VW n IN UPPER PORTION OFATTIC n 117 o1,Xy IN, Grou bfa OFF RIDGE VENTILAT10N AREA = 115 SQ IN.PER VENT 567.36/115 441 N.RONALD REAGAN BLVD. TOTALIIOFVENTS REQUIRED = 4.93357 LONGWOOD,FL 32750 TOTALBOFVENTS PROVIDED = 5 I PH407_774-8078 +/-IS'-II BLCG.HGT. - - - - - 'AREAOFATTIC IS THE PERIMTEROFTHE HOUSE,LESSTHEOVERH4NG FAX:407-774.4078 (EIRERIOR OF WALLTO E)MRIOR OF WALL.NO OVERHANGSSNCLUOED) www.abdesigngmup.com FYPON LV12X24 ---_ m SHINGLE AA#:0003325 OR EQUIVALENT - ROOF 6 OFF RIDGE VENT F 12 BKTIDCIT OR h EQUIVALENT R: 0 h 8'-8' HGT. BRG. — — 8—� I'-0' -- .J 16'X62'FYPONi_0 ® v m� EQ R OR ❑� ❑ �„� 0 EQUIVALENT I ' ' ' ' ' ' r SAND CTYP.J r 0'-0'FIN.FLR — — 0' 0'-0'FIN.FLR — — _ — — — — 0�FIN.FLR RO T ELEVATION REAR ELEVATION TEXTURED FINISH TEXTURED FINISH OFF RIDGE VENT OFF RIDGE VENT • I'-0 22 n 12 \I 8'-8'BRG.HGT.-� - - - - - - - - - - - - - - ,_0. v ) BUBDIV. dt LOT. ''"'J " SILVERADO ■ LOT 2 ,LOUVER DETAIL BLK 1 \. l SCALE:112'= 1'-0' PROJZCT 04128.000-02012 MODEL -0'FIN.FLR 4EBB 111828-CALI" LEFT ELEVATION TEXTURED FINISH LEFT PAGE: FRONT,REAR, OFF RIDGE VENT OFF RIDGE VENT LEFT & 12 �6 RIGHT ELEVATIONS 150 MPH B 8TA - C'-8'BRG. T. 1 1 'v v A NOW 0'-0'FIN.FLR 0'-0'FIN.FLR DPA�E 2-12-21 - - - - - - - - - - - BCALE:1/4"=1'-0" __ SHEET RIGHT ELEVATION TEXTURED FINISH 3 D A R C N I T E C T s EQ. Ea Design Ea EQ, EQ. Ea Grou .-, 441 N.RONALD REAGAN BLVD. LONGWOOD,FL 32750 a•,, PH:407-774-6078 WAS) FAX.407-774.4078 TYP. s www.abdesigngroup.com 1 AI AA#:0003325 I I 7 4L. TYP, " 1 B { ij11 ' T1r I II I I I __ E® I II FRONT EVATION REAR ELEVATION pr� I w A TYP iBDIV & LOT SILVERADO II LOT 2 BLK 1 04122 00#-02012 LEFT ELEVATION MODS4EBB "1828-CALI" GARAGE S717NG: LEFT PAGE: WALL ASSEMBLY ELEVATIONS 150 1 EXP TEOF I = = =I I g 15, /1 AA ■ II II IITYR II I I I I NO 9373 II II PA�D 2-12-21 SCALE:1/4"=1'-O" RIGHT ELEVATION [ 3D, 2 2 ARCHITECTS LOAD CALCULATIONS ONE FAMILY DWELLING WITH HEAT PUMP SEC CODE VV HOUSE PLAN: MODEL '"CALI" LOAD INFORMATION VA 7628 8Q Pt GENERAL UGITTEG E S VA PEN 9p PT 6494 - POtJ 2 YO AID'APPLWICE CQtl.=A1',600 YA Yl 3000 Des n A:ANAI I 1 yl fin. 1ppG CEILING Gi lea LIVING ROOM MTD.LIGHT 1 nwrmE LOT xwle➢uTs nwrOrc of coomoProYaN 12oG6 )"t TO BE I I EA asATme 4a6o INSTALLED,I 1 �� 1441 N.RONALD REAGAN BLVD. OWNER'S r PRE-WIRED WP I PROVIDE I — LONGWOOD,FL32750 SUITE CLG FAN GFI I J-BOX FORI I c1ATTE3 D 6084 PH:407-7746078 r \ / OPT.FAN I 1 DISPOSAL 600 FAX 407-774-4078 �� www.abdesigngmup.com \ ———_ --...— 1 lac9GxAVE lobo AA 8:0003325 PRE-WIRED \\ � 1 1�cs�TOR 1200 GLG FAN \ \ 1 n DINING SUDIOTAL OF GENERAL LOAD 80884 ROOM FDi9T 10 OVA O➢GENERAL TOAD AT 100L 10000 (� U I It - ' tiDIwINDER or GENERA,LOAD AT 40%2852.VA 0.4 10364 I S O I — TOTAL HINT GENERAL LOAD 2086_ i I I 35 TON AT PU1D'(T/SOT EMZNGENCY NEAT STRIP) Ry r 21 AMP s 240 VA --- / / HE // ——_ as TOM IO COOiG 3Y3f4Y 40 A1@ s f110 Y •BBOD x / NET GENERAL LOAD 20304 !/ �� ----- '6ITLET ITCH M NET TOTAL 0850 cbob y0. FOR OW CABINET TOTAL LOAD acc6_ 01 1 CALCULATED LOAD FOR SERVICE D. aces_ VA/04O w 126 w1G• jBATH `1 GFI — GF1 I 150 AMP SERVICE GPI I — I---- — rte--1 •x/9sr c 6 CAuvR-wTw�em.DYAe LOAD J \ DW I IREF I `Y`{ \ 5 \ KITCHEN NEUTRAL CALCULATION: --� -- L VP I � LI300IDIVA•P002,REMAINDER s LIA24CE,LAUNDRY LOADS: I4Z83 VA p1 LAUN. _ PAN. NET LOAD: 8,40 VA I ----- / RANGE:12.000 i l0% 8,400 VA —— / RANGE / DRYER:5,000•10% 3500 VA 31 / GFI GFI NEUTRAL AMPAGITY: 13,448 1240 18 A TOTAL 18+849 VA BDRM. --J __ A2 AL MINIMUM NEUTRAL CONDUCTOR u / I E I / I I = OUTLET WIRE W/ I I FUTURE MICRO _ • PRE-WIRED Sp. CLG FAN CJ 5Oj I BDRM.#3 "_,,.� I I I -— I- II I / 7� E IRA I I I I PRE-WIRED / CLG FAN 41- 5p r O A4•FF. r----- ' I � � � GARAGE DOOR I _�I sv>eDLv & LOT COND.I BOLLARD / I AS REG. / S9 SILVERADO LOT 2 PER BLDG. / `�-- L-_-J CODE WALL MOUNTED // LIGHT W/SWITCH I I I BATH #22 BLK 1 / ATTIC I L / 1 I ,� KEYLESS 41 8 00-02012 FIELD w th FIXTURE • \ MODEU METER LOG - IL CLG. \ 4EBB OUTLET \\ BDRM.#2 "1828-CALI" IRRIGATION OUTLET• GARAGE awDlG. 48'AFF. r/ �J^{ )--C LEFT GFI P GARAGE - I CLG FANWIRED PAGE ELECTRICAL FOR I PLAN 150 E . 1AA /ATE ELECTRICAL PLAN g � 0 NO 937 DATE_ 2-12-21 9CALIO 1/4"=1'-0" skim=T 5