HomeMy WebLinkAbout21-1543 � O F���Ii,•III._ City of Zephyrhills PERMIT NUMBER 5335 Eighth Street Zephyrhills, FL 33542 BNR-001543-2021 Phone: (813)780-0020 Fax: (813)780-0021 Issue Date: 03/19/2021 Permit Type: Building New (Residential) Property Number Street Address 32 25 21 0040 01300 0220 35832 Morse Willow Court Owner Information Permit Information Contractor Information Name: D R HORTON Permit Type:Building New(Residential) Contractor: D R HORTON INC Class of Work:SFR Construct Address: 12602 Telecom Dr Building Valuation:$160,000.00 TAMPA,FL 33637 Electrical Valuation:$8,200.00 Phone: (813)549-1968 Mechanical Valuation:$6,000.00 Plumbing Valuation:$9,500.00 Total Valuation:$183,700.00 Total Fees:$14,770.94 Amount Paid:$14,770.94 Date Paid:3/19/2021 12:48:18PM I•t✓v���' I Project Description CONSTRUCT SINGLE FAMILY 3,713 SO FT SILVERADO Application Fees Transportation Impact Fee-City $36.32 Transportation Impact Fee $3,595.68 Public Safety Impact Fee-Admin $26.35 Building Permit Fee $830.00 Address Fee $30.00 Plumbing Permit Fee $87.50 Building Plan Review Fee $415.00 Mechanical Permit Fee $70.00 School Impact Fee $8,328.00 Electrical Plan Review Fee $40.50 SIF 1 percent Fee $83.28 Plumbing Plan Review Fee $43.75 Park Impact Fee-Single Family/Townhome $769.56 Mechanical Plan Review Fee $35.00 Driveway Fee $45.00 Electrical Permit Fee $81.00 Public Safety Impact Fee-Police $254.00 REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each subsequent reinspection. Notice: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permit required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property.If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. /D? - y)Q9L4_) CONTRACTOR SIGNATURE PE IT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INVOICE1111 ® ' • BILLING CONTACT DAVID GUDE D R HORTON INC 12602 TELECOM DR TAMPA, FL 33637 INVOICE NUMBER INVOICE DATE INVOICE DUE DATE INVOICE STATUS INVOICE DESCRIPTION INV-00002852 03/16/2021 03/16/2021 Due NONE REFERENCE NUMBER FEE NAME TOTAL BNR-001543-2021 Address Fee $30.00 Building Permit Fee $830.00 Building Plan Review Fee $415.00 Driveway Fee $45.00 Electrical Permit Fee $81.00 Electrical Plan Review Fee $40.50 Mechanical Permit Fee $70.00 Mechanical Plan Review Fee $35.00 Park Impact Fee-Single Family/Townhome $769.56 Plumbing Permit Fee $87.50 Plumbing Plan Review Fee $43.75 Public Safety Impact Fee-Admin $26.35 Public Safety Impact Fee-Police $254.00 School Impact Fee $8,328.00 SIF 1 percent Fee $83.28 Transportation Impact Fee $3,595.68 Transportation Impact Fee-City $36.32 35832 Morse Willow Court Zephyrhills, FL 33541 SUBTOTAL $14,770.94 REMITTANCE INFORMATION TOTAL $14,770.94 City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 March 16,2021 5335 8th Street,Zephyrhills,FL 33542 Page 1 of 1 PASCO COUNTY, FLORIDA _ Permit No. c Data Permitted Z- Z Builder Name/Owner Name Control County Parcel No. 32- Z-5 Z] 0( 6 02W SubDiv: cSl Address/Locadon 3 2- 1ba) Cr Classificationrrype of UsQ C.1 t TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑Yes [] No (_ How Determined Impact Fee Amount $. ��� Zone No. TAZ: SCHOOL IMPACT FEE 4 Account (056) Single-Family Detached House Amount $ (05.7) Mobile Home —r (058) Other Residential d 23) Collection Fee Exempt Yes- 0 No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT Exempt El Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes No How Determined Total Amount4D­_�_ RESOURCE FEE ERU TOTAL AMOUNT Prepared By - Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AM04NTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply recelpt of a copy of this form,placing the building permit owner,on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY City of Zephyrhills Permit Application Fax 813-780-0021 Building Department Date Received covv) Phone Contact for Permitting Owner's Name nr Owner Phone Number 1z_qi 1. Owner'sAddress Owner Phone Number -Fee Simple Titleholder Name owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 114oesi M-1--aJ 64"'e'-_2g-p11.y&1yws, -33 / LOT# SUBDIVISION PARCELID# 32-Z-5ZI-004001300 -0Z?,Q (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH e . INSTALL El REPAIR PROPOSED USE SFR 'co mM OTHER TYPE OF CONSTRUCTION V BLOCK Q FRAME STEEL DESCRIPTION OF WORK :51mIg Fawlilm resiJea-L 3,5 Al -fy6a4 BUILDING SIZE sQ FOOTAGE F2,f_Y&A7/3#* HEIGHT QBUILDING VALUATION OF TOTAL CONSTRUCTION F-:71ELECTRICAL AMP SERVICE 0 PROGRESS ENERGY W.R.E.C. EZ:fPLU'MBING IZIMECHANI'CAL ' o oI VALUATION OF MECHANICAL INSTALLATION o - =GAS ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS 132'Iflo 77 FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED YtN I FEtCURREi Y/N Address 0?_ me)g cwi ItrT414 I License# lcsco'sc� ELECTRICIAN COMPANY . Ar4 Ejer+p- r SIGNATURE REGISTERED Y/ N I ' FEE-CORREN L_Y!N Address jdlnz� License# Q()3-1 PLUMBER > COMPANY pluiane (z SIGNATURE REGISTERED Y1 N 'FEE CURB Address 6, BW RD?) 33GI 1- License# C MECHANICAL COMPANY SIGNATURE REGISTERED f I'N i FEECURREN -ff_Y_LN _J Address Cf I�J e SA J(A 34�S__� License# CPrC033 � lae- OTHER COMPANY MA mah_rl SIGNATURE REGISTERED Y1 N 1 FEE CURREN Y/N Address &g 3 License# flItIlIIITIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIHIIIIIIIIIIIIIIIIIIIIIIIIIIIIll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans-,(I)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days-after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Slit Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&I dumoster.Site Work Permit for all new projects.All commercial requireffients must-meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. *PROPERTY SURVEY required for all NEW construction, Directions- Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (AJC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone With notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Fcotag6),:­11..; Driveways-Not over Counter if on public roadways..rieeds ROW II NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any, r. applicable deed restrictions.' UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and focal regulations. If the contractor is not licensed as.required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing.Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have thb contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not prop erly.licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILI"I DES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings,.or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at,the time of permitting. It is further understood that Transportation Impact Fees'and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power.release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County WaterlSewer Impact fees are due, they must'be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): if valuation of work is $2,500.00 or more, 1 certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that 1-have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: 1 certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. 1 certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. 1 also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include,but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions.apply to the use of fill: Use of fill is.not allowed in Flood Zone W" unless expressly permitted. - if the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill'material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - if fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. if use of fill is found to adversely affect adjacent properties, the'owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) mouths after the time the work is commenced. An extension may be requested, in writing, from the Building O.ff'l.cial for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the.extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER'OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. "— FLORIDA JURAT(F.S.117.08) OWNER OR AGENT — CONTRACTOR �Subsc• ed nd sworn to(or affir d)befor me this Subscribed and sworn to(or affirmed)before me this by �Sa n r` Ll f t r1� by Wh is/are personally knowri to me or has/have prodbred Who is/are personally known to me or has/have produced as identification. as identification. °&xi€_A� Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped 7$,eN3Mry Publle State of Florida helle Moyes �ommlaaion HH 088es7 lles 12/21/2024 ' � r Single :Family Dwelling Plan Review Comments 1. F:F.E...shall be a minimum of 8"above the road elevation and an engineered site plan. 2. Lots shall be graded.to.comply with R401.3 of the F.B.C. 3: Compaction test required if 24" or more of fill dirt is brought in at any one place. 4: Tie in survey required before pouring concrete: 5. Driveways require a R.OM.use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7 All.property markers shall be uncovered_and.marked at tin' of first inspection. 8: All A.D.A.requirements shall be met: . . 9-. No electric,plumbing;mechanical,or framing shall be covered without an inspection and approval first. 10.. All Garages shall comply with section R302:6 of the F.B.C. (Fire Separation).. 11. Appliances.shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4.of the F.B:C 12. Water heaters sha11-comply with section P607.3 of the F.B.C: 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1- . 14. Return air iri all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.G. 17. All means of egress are.to be=in accordance with R311 of the F.B.C. 18. "Green gypsum.board" shall not be used as a backer in showers or tubs.R702.4.2 F.B.C. 10. Combination-type AM breakers are required at all locations requiring an AM type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C: 21. All plumbing, mechanical, and electrical shall be separate from unit to unit: This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced: 23. Tamper- Resistant Receptacles in accordance with 406.11 of the„2016 N.E.C. 24. In accordance with the Land Development Code,lots..shall be sodded before final of least 10 feet around the structure. :25-. R403.5.3Hot wate. pipe insulation _Insulation for hot:water pipe with-a minimum thermal resistance (R-value) of,R-3 shall.be applied to the following:,_ , PipingV4 inch (19:1 mm)and larger in.nominaa.diameter. Piping,serving more than one dwelling'unit: Piping located outside the conditioned space: Piping from the water heater to a distribution manifold.. Piping located under.a floor slab. Buried in piping.: Supply and return piping in recirculation systems other than demand recirculation systems. 25.Blower door test shall be provided before C.O. 26.A copy of the energy.caels'shall be:with permit at all times 27.. Copy of vial insulation report shall be provided with permit Before fnaL 28.No fence,pool or-screen'enclosure :is issued with:thispermit.` F.F.E.-Finished Floor Elevation - RB.C-.Florida Building Code 6t'Edition R.O.W.-Right of Way - A.D.A. Americans with Disabilities Act N.E.C.-National Electric.Code(2016) PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 22, BLOCK 13, SILVERADO RANCH SUBDIVISION PHASE 10A AS RECORDED IN PLAT BOOK 80, PAGE(S) 107-112, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. MORSE WILLOW COURT TRACT F 60' WIDE PRIVATE RIGHT OF WAY (REFERENCE BEARING) _ __9 136.921 C N89*SS52E _ 1p_I CENTERUNE OFJ 10250' 34.46 RIGHT—OF—WAY 9 '53*89 N8953 2"E:47.50 1* z = 30' 10,PUE SCALE 15 30 r 7.5! N 20& z10.3-1, I cn Isl ( 0 0I t ;a COVERED 0 M M ENTRY I C5 -U C5 mucri—GEN KITCHETTE' 00 00 M LOT 23 ca BLOCK 13 PROPOSED 0 2795—CAMDEN 9 FINISHED FLOOR o, ct ELEVATION-1,32 80' 50.w 0 i I Ln 0 I&S �0 7­7 0 9 93O.-r I 5! BLOCK 13 8,203 M FT d: kt DRAINAGE TYPE A S89*53'52"W 72.50' LOT 21 BLOCK 13 PREPARED FOR: Curve Table Curve 01 Length Radius I Delta Chord Bearing Chard ION* CI .39.2-r 25.00'[GliFWOD' N44'53'52"E 35 AW "_04$4S.' BUILDING SETBACKS LEGEND: BUILDING SETBACK LINE FRONT; 20' ON LOT CALCULATIONS CENTERLINE REAR: 15! LOT = 8,203 SO. FT RIGHT OF WAY LINE SIDE- 5! (51Y LOTS) LIVING AREA = 2,836 SO. Fr. 7.5' (55' & 60' WIDTH LOTS) GARAGE = 619 SQ. Fr. PROPOSED ELEVATION SIDE STREET: 15* ENTRY = 65 SO. Fr. PROPOSED DRAINAGE FLOW NOTES: LANAI = 193 SO. FT. MULTI—GEN = 25 SO. Fr. CONCRETE PLANS PROVIDED BY THE 1, ELEVATIONS SHOWN ARE PER LOT GRADING DRIVEWAY 680 SO. Fr. A/C AIR CONDITIONER DRIVEWAY2. ELEVATIONS ARE BASED ON NAVD 1988 A/C PAD = 9 SO. FT. Shy SIDEWALK WALKWAY 23 SO. FT. POINT OF INTERSECTION DATUM. IMPERVIOUS 54% PC POINT OF CURVATURE 3. FOR ALL LOTS WHERE SIDE—YARD PT POINT OF TANGENCY 4450 SQ. FT. RP RADIUS POINT SETBACKS ARE LESS THAN 7.50 FEET, A SOD 3,753 SO. FT. PRC POINT OF REVERSE CURVATURE MINIMUM 5.00 FOOT WIDE DRAINAGE AND ACCESS EASEMENT IS REQUIRED PER PASCO OFF LOT CALCULATIONS PCC POINT OF COMPOUND CURVATURE TYP TYPICAL COUNTY LAND DEVELOPMENT CODE. RIGHT OF WAY = 3563 SQ. FT. CS CONCRETE SLAB DRIVE APRON = 302 SO. FT. (P) PER PLAT (C) THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES PUBLIC S/W = 1071 SO. FT. CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF SOD = 2,110 SO. FT. PB PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND TOTALS PGS PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK AREA = 11,766 SQ. FT. SO.FT SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. DRIVEWAY = 1.062 SQ. FT. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM I SIDEWALK = 1094 SO. FT NGVD NATIONAL GEODETIC VERTICAL DATUM THIS IS NOT A SURVEY SOD — 5,863 SO. FT. D&UE DRAINAGE&UTILITY EASEMENT POE PRIVATE DRAINAGE EASEMENT THIS IS A PLOT PLAN ONLY PUE PUBLIC UTILITY EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.P-M.MAP NO.1210ILD288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 2%2014,AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS. RIGHT APPEARS ID UE IN ZONE'r, AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAJN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS:BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF MORSE 3. NOT VALID WITHOUT THE AUTHENTIC A5M ELECTRONIC SIGNATURE AND THE AUTHENTIC WILLOW COURT BEND NB9'5SS:rF,PER PLAT. ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) REVISED: M I—= Fz;,* I CAN SURVEYOR AND MAPPER. U F--',\/IFE N'I "4Z3 oDigitally signed bylarnes W Boleman ON:c=US,st=Fluridla.toOrtando, SCALE 1'—30 FEET 8L MAPPING INC. Zi�•j • -AMEFU CAN SURVEYING&MAPPING, W.-INC.—jameswilafeman, APPROVED BY: is CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 _V�%.%:-1"F.01 err,ail bole�n@asworparatexom FOR Datc,:20211.01.2113AM2-051DO THE 200647 LOT 22,BLOCK 13 FIRM 3191 MAGUIRE BOULEVARD, SUITE 200 A 1 JOB NO. ORLANDO, FLORIDA 32803 ar, (407)426-7979 0 DRAWN BY. DSB 1 PLOT PLAN 01/1412021 JG WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE Z 1 - 813-780-0020 City of Zephyrhills Permit Application Fax 813-780-0021 Building Department Date Received —/ Phone Contact for Permitting dsbeauchaine@drhorton com Owner's Name DR Horton Tric Owner Phone Number 813-549-1968 Owner's Address 12602 Telecom Drive,Tampa,FL 33637 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address �� JOB ADDRESS ( D/'S� I D Ld C LOT# SUBDIVISION .A__dL� �� t� -----;) PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED R NEW CONSTR B ADD/ALT = SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR 0 COMM OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME STEEL = DESCRIPTION OF WORK � BUILDING SIZE SQ FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS E Oq NE =PLUMBING $ e3 =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION ` l�l =GAS = ROOFING 0 SPECIALTY = OTHER 1 FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER ® COMPANY DR Horton,Inc SIGNATURE REGISTERED Y/N I FEE CURREN Address 12602 Telecom Drive,Tampa FL 33637 License# CBC039062 ELECTRICIAN COMPANY Strada Electric SIGNATURE REGISTERED Y/N EE CURREN Y/N Address 3400 St Johns Pkwy,Sanford,FL 32 License# EC13003715 PLUMBER COMPAN Northwest Plumbing SIGNATURE REGIS ED Y/N FEE CURREN Address 6310 Mableton Pkwy,St 1000,Mableton,GA 126 ense# CFC1427137 MECHANICAL COMPANY Progressive Air ms SIGNATURE REGISTERED Y/N J FEE CURRE Address 7130 Meighan Ct,New rt Richey,FL 34652 License# CAC033 OTHER COMPANY Brad McDonald Roofing SIGNATURE REGISTERED Y/N FEE CURREN Address 7143 SR 54,New Port Richey,FL 34653 License# CC1325833 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R=0-W Permit for new construction, Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisionsAarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. sae Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required.(A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING . (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what.licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009. Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy'or final power release.If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant, have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance.Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE-OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT, FLORIDA J URAT(F.S.117.0q OWNER OR AGENT CONTRACTOR Subs ib and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this Subs Deanne Beauchaine by W o is/a a personally known to me or has/have produced Who is/are personally known to me or has/have produced 6 as identification. as identification. ,4e 13 " Notary Public Notary Public on No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Notary Public Sfete of Florid® MlOh€slle PAoyes ° My�Cifl9flllssion NH 066897 1212112024 0 R PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 22, BLOCK 13, SILVERADO RANCH SUBDIVISION PHASE 10A AS RECORDED IN PLAT BOOK 80, PAGE(S) 107-112, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. MORSE WILLOW COURT TRACT F 60' WIDE PRIVATE RIGHT OF WAY PI (REFERENCE BEARING) _ --�N�$9'53'S2"E 736.96' CENTERLINE OF/ 102.50' 34.46 i RIGHT—OF—WAY 1 Z I I! , 00o qP= :j3o.6e N89'53'52"E;47.5 — Z '30 1 30 10' PUE ( :.:.:(;' I GRAPHIC SCALE 0 15 30 v. rn I ;. • 15.0' 7.7':' __r s N. 20.W 7.5' N y I ':°'` y I 0 I COVERED i ,5.3' ENTRY 1 0 I W I ci� I LOT 22 I o mo>�m CK 13 Uo i A eB204 SO. FT f i TT7 LOT 23 = I Ct DRAINAGE TYPE A cn BLOCK 13 o ( PROPOSED ,ta l o O 2795 — CAMDEN B oo I R° FINISHED FLOOR P' n D FCTI I �x ELEVATION=132.80' m I I j I —50.00 C0 i I U1 0 I 19.3' 1 REV E.R E_. Ey�A DATE cF TyE y�R L 15.01 7.5' PH !0 ' p/AV rn HILL o' ad Uj� 2 cY S89"53'52"W 72.50' tq+FL�pLy es I LOT 21 NgTlp�q�bGRiO� J 'LYVvp 'IV f y BLOCK 13 rHCL�CTR/C L?111�G Clio . PREPARED FOR: Curve Table Carve length I Radius Del ta Chord Bearing Chord D I�HOli1�No N ti , C7 1 39.27'1 25.00' 90-00-00" N44-53'52'E 35.36' LEGEND: BUILDING SETBACKS — — •— BUILDING SETBACK LINE FRONT: 20' ON LOT CALCULATIONS _ — 1S' � "'— CENTERLINE REAR: SIDE: 1 {50' LOTS} LOT = 8,203 SQ. FM — _ _ RIGHT OF WAY LINE 7.5' (55' & 60' WIDTH LOTS) LIVING AREA = 619 SQ. FT.SQ. FT. GARAGE = PROPOSED ELEVATION SIDE STREET: 15' 5 ENTRY = 65 SQ, FT. PROPOSED DRAINAGE FLOW NOTES: LANAI = 193 SQ. FT. —) CONCRETE 1. ELEVATIONS SHOWN ARE PER LOT GRADING DRIVEWAY = 25 SQ. FT. J PLANS PROVIDED BY THE CLIENT. A/CDRIVEWAY = 680 50. FT. A/C AIR CONDITIONER 2. ELEVATIONS ARE BASED ON NAVD 1988 WALKWAY PAD = 9 50. FT. pi SIDEWALK DATUM. WALKWAY = 23 SQ. FT. Pl POINT of INTERs£CnoN IMPERVIOUS = 54% PC POINT OF CURVATURE 3. FOR ALL LOTS WHERE SIDE—YARD 4450 SQ. FT. PT POINT OF TANGENCY SETBACKS ARE LESS THAN 7.50 FEET, A RP RADIUS POINT MINIMUM 5.00 FOOT WIDE DRAINAGE AND SOD = 3,753 SQ. FT. PRC POINT OF REVERSE CURVATURE ACCESS EASEMENT IS REQUIRED PER AND OFF LOT CALCULATIONS PCC POINT OF COMPOUND CURVATURE COUNTY LAND DEVELOPMENT CODE. RIGHT OF WAY = 3563 SQ. FT„ TC1S'P CONICRETE CAL SLAB DRIVE APRON = 382 SQ. FT. PER PLAT THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES PUBLIC S/W = 1071 SQ. FT, (�j CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF SOD = 2,110 SQ. FT. PB PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND TOTALS PGS PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK AREA = 11,766 SQ. FT. SQ. FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F1R.M. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. DRIVEWAY = 1,062 SQ. FT. F„LR„M. FLOOD INSURANCE RATE MAP SIDEWALK = 1094 SQ. FT. NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY. NGVD NATIONAL GEODETIC VERTICAL DATUM 5QQ = 5,863 SQ. FT. LIE DRAINAGE do UTILITY EASEMENT POE PRIVATE DRAINAGE EASEMENT THIS IS A PLOT PLAN ONLY PUE„ PUBLIC UTILITY EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CD288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE HAVE SEPTEMBER 26, 2014, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO UE IN ZONE"X", AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0,2R ANNUAL CHANCE FLOODPLAIN, THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION, 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: A5hA3. NOT VAUD WITHOUT THE AUTHENTIC BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF MORSE ELECTRONIC SIGNATURE AND THE AUTHENTIC WILLOW COURT BEING N89'53'S2'E,PER PLAT. �—^^ ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A-M E FR I Ur A N SURVEYOR AND MAPPER. DBe=omigAli5tMi l=EjRbInC lAeNm a nb@yaJsammceasr Wpo B raotlee .mcoaan (FIELD DATE:) DN:=US,1t-FI =Orando,U Y SURVEYING& : i"= 3Q FEET J „-,MAPPING INC.cn=lamesWSGALE � PPINV INC. eman, APPROVED BY: CERTIFICATION CATION OF AUTHORIZATION NUMBER LB/6393 F OR 3191 MAGUIRE BOULEVARD, SUITE 200 ate:2021 A4.2708:46:00.04'00' THE JOB NO. 'ORLANDO, FLORIDA 32803 Adobe Acrobat-.1— L0,23 FIRM 200647 LOT 22,BLOCK 73 -.1— DSB REMOVE DOOR 04/27J21 NMK WWWAMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 648 426-7979 5 p0.� DRAWN BY: PLOT PLAN 01 14 9021 JG