HomeMy WebLinkAbout21-1563 a
riuiin,n City of Zephyrhills PERMIT NUMBER
5335 Eighth Street
Zephyrhills, FL 33542 ELCMISC-001563-2021
Phone: (813)780-0020
Fax: (813)780-0021 Issue Date: 03/12/2021
Permit Type: Electric Service Replacement/Misc
Property Number Street Address
24 26 21 0110 00000 2910 3107 Nubbin Ridge Lane
Owner Information Permit Information Contractor Information
Name: ANNISTECIA HALLIBURTON& Permit Type:Electric Service Replacement/M Contractor: US SOLAR
JOSEPH POWELL&JONTHAN Class of Work:Add/Alter Residential
Address: 3107 Nubbin Ridge Ln Building Valuation:$32,140.00
ZEPHYRHILLS,FL 33540 Electrical Valuation:$5,000.00
Phone: (813)693-7235 Mechanical Valuation:
Plumbing Valuation:
Total Valuation:$37,140.00
Total Fees:$398.55
Amount Paid:$398.55 v
Date Paid:3/12/2021 2:10:42PM
Project Description
INSTALLATION ROOF MOUNT SOLAR
Application Fees
Electrical Permit Fee $65.00 Electrical Plan Review Fee $32.50
Plan Review Fee $100.35 Building Permit Fee $200.70
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each subsequent reinspection.
Notice: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permit required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner:Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications add fee Must Accompany Application.All work shall be performed in
accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
ONTRACTOR SIGNATURE PE IT OFFICE
PERMIT EXPIRES I MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building bepartmerit
Date Received Phone Contact for Permitting ( 81 3 ) 808 — 0218
Owner's Name Joseph Powell Owner Phone Number ((813) 693-7235
Owner's Address F107 Nubbin Ridge Lane,Zephyrhills,FL 33540 Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 3107 Nubbin Ridge Lane, Zephyrhills, FL 33540 LOT# 291
SUBDIVISION HIDDEN RIVER PH 2 PARCEL ID# 24-26-21-0110-00000-2910
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR ADD/ALT 0 SIGN Q 0 DEMOLISH
INSTALL e REPAIR
PROPOSED USE SFR 0 COMM = OTHER
TYPE OF CONSTRUCTION BLOCK FRAME = STEEL
DESCRIPTION OF WORK ROOF MOUNTED SOLAR PANEL INSTALL
BUILDING SIZE SQ FOOTAGE HEIGHT
BUILDING $ 32,140 VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ 51000 AMP SERVICE = PROGRESS ENERGY = W.R.E.C.
=PLUMBING $ r16�2_3
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION �
��Chi'
=GAS = ROOFING Q SPECIALTY = OTHER 0,t3'
y'- �_ p
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES NO "/ `
BUILDER COMPANY 7 US SOLAR
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address 2732 Broadway Center BLVD.Brandon,FL 33510 License# CVC57002 11
ELECTRICIAN COMPANY [::G:E:N:ESIS ELECTRIC SERVICES LLC.
SIGNATURE REGISTERED Y/N FEE CURREN I Y/N
Address 2825 Murray Pass, Odessa FL 33556 1 License# EC13007122
PLUMBER COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License#
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License#
OTHER COMPANY
SIGNATURE REGISTERED Y/N FEE CURREN Y/N
Address License#
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date.Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum:ten(:10):workvt�g daySafter submittal date.Required onsite,Construction Plans,Stormwater Plans w!Silt Fence installed,
'Sanitary Facilities&.1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN I?ERMIT.` -Attach'(2)`•sets bf Engin746i,Pl2hs.
*'*PR OPERTY•SURVEYied 'd for all NEW construction,
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required.(A(C upgrades over$7500)
`* Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW S o I a r
Local Experts who Care
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Euilding Department
NOTICE OF DEED RESTRICTIONS:The undersigned understands that this permit may be subject to"deed"restrictions"which may be more restrictive
than County regulations.The undersigned assumes responsibility for compliance with any applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES:If the owner has hired a contractor or contractors to undertake work,they
may be required to be licensed in accordance with state and local regulations.If the contractor is not licensed as required by law,both the owner and
contractor may be cited for a misdemeanor violation under state law.If the owner or intended contractor are uncertain as to what licensing requirements
may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-8009.
Furthermore,if the owner has hired a contractor or contractors,he is advised to have the contractor(s)sign portions of the"contractor Block"of this
application for which they will be responsible.If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is
not entitled to permitting privileges in Pasco County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or
expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended.The undersigned also understands,that
such fees,as may be due,will be identified at the time of permitting.It is further understood that Transportation Impact Fees and Resource Recovery
Fees must be paid prior to receiving a"certificate of occupancy"or final power release.If the project does not involve a certificate of occupancy or final
power release,the fees must be paid prior to permit issuance.Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior
to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended):If valuation of work is$2,500.00 or more,I certify that I,the applicant,
have been provided with a copy of the"Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of
Agriculture and Consumer Affairs.If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described
document and promise in good faith to deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT:I certify that all the information in this application is accurate and that all work will be done in compliance with
all applicable laws regulating construction,zoning and land development.Application is hereby made to obtain a permit to do work and installation as
indicated.I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all
laws regulating construction,County and City codes,zoning regulations,and land development regulations in the jurisdiction.I also certify that I
understand that the regulations of other government agencies may apply to the intended wort,and that it is my responsibility to identify what actions I
must take to be in compliance.Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to
commencing construction.I understand that a separate permit may be required for electrical work,plumbing,signs,wells,pools,air conditioning,gas,or
other installations not specifically included in the application.A permit issued shall be construed to be a license to proceed with the work and not as
authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from
thereafter requiring a correction of errors in plans,construction or violations of any codes.Every permit issued shall become invalid unless the work
authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a
period of six(6)months after the time the work is commenced.An extension may be requested,in writing,from the Building Official for a period not to
exceed ninety(90)days and will demonstrate justifiable cause for the extension.If work ceases for ninety(90)consecutive days,the job is considered
abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YQ1JR LEblDER OR AN ATTORNEY BEFORE REGORDINQ YOUR NQT[ 1`101 I'm.ENCEM ENT,
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this
by 02/11/2021 by Seann Gates
Who is/are personally known to me or has/have produced Who is/are personal)yy known to me or has/have produced
as identification. DL as identification.
Notary Public Notary Public
Commission No. Co ission No. GO 959064
Jason S. Monchgesang
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
JASON S. MONCHGESANG
, Notaryy-Public-State-of-Fierida --
Commission N GG 959064
� My Commission Expires
February 17, 2024
olar
Local Experts who (Care
DocuSign Envelope ID:B2DADF5A-62BF-438F-AA69-2886CF1FAD20
CONTRACT FOR SALE AND INSTALLATION OF A 9.60 SYSTEM
(hereinafter the"System")by and between US Solar Squared,LLC(hereafter"Seller"whose address is below provided)and
Joseph Powell Annistecia Halliburton (hereinafter jointly or severally"Buyer")whose address is
3107 Nubbin Ridge Lane Zephyrhills Florida 33540 according to the terms and conditions hereafter stated. Buyer
understands and agrees that this contract is binding only when accepted by Seller by having its duly authorized company officer or member execute this
contract.Buyer further understands and agrees that the full contract price for purchase and installation of the System shall be the following price
$38 140.00 unless amended by subsequent agreement of the parties. Buyer further acknowledges and agrees that Buyer is not to give
the sales agent presenting me this contract any money or check as the sales agent is an independent contractor and is not authorized to collect
money on behalf of Seller.
TERMS AND CONDITIONS
MECHANIC'SLIENNOTICE: ACCORDING TO FLORIDA'S CONSTRUCTION LIEN
LAW (SECTIONS 713.001 - 713.37, FLORIDA STATUTES),THOSE WHO WORK ON
YOUR PROPERTY OR PROVIDE MATERIALS AND ARE NOT PAID IN FULL
HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR
PROPERTY IF YOUR CONTRACTOR OR SUBCONTRACTOR FAILS TO PAY
SUBCONTRACTORS, SUBSUBCONTRACTORS, OR MATERIAL SUPPLIERS. THE
PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR
PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL.
IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO
HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR
PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR,
MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A
SUBCONTRACTOR MAY HAVE FAILED.TO PAY. TO PROTECT YOURSELF, YOU
SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS
MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU. WITH A
WRITTEN RELEASE OF LIEN FORM ANY PERSON OR COMPANY THAT HAS
PROVIDED TO YOU A "NOTICE TO OWNER." FLORIDA'S CONSTRUCTION
LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN
ATTORNEY.
BUYER'S RIGHT TO CANCEL
This is a home solicitation sale,and if you do not want the goods or services,you may cancel this contract by providing written
notice to the Seller in person,by telegram,or by mail.This notice must indicate that you do not want the goods or services and
must be delivered or postmarked before midnight of the third business day after you sign this contract. If you cancel this
contract,the seller may not keep all or part of any cash down payment.
Date Buyer signed this contract is: 2/4/2021 _. If Buyer decides to cancel this contract,Buyer will send the cancellation
notice to Seller at its address provided below within three business days after this date.
By signing below,Buyer agrees to the terms and conditions stated above and on the reverse side of this page.
Buyer(s): f rB.rge9l poyuse must sign as well). DocuSigned by
BY BY
F52E209B4E81475... �F52E20964E81475...
ACCEPTANCE:By signing below,Seller hereby accepts Buyer's offer according to the terms and conditions stated above and on the reverse side.
DoeuSigned by:
US Solar Squared,LLC B,
2732 Broadway Center Blvd. Seann Gates,Preks'Kfent
Brandon,Florida 33510 20A494735BBM9A...
State License#CVC57002 Date Accepted 2/4/2021
CHAPTER 558 NOTICE OF CLAIM
CHAPTER 558, FLORIDA STATUTES, CONTAINS IMPORTANT REQUIREMENTS YOU MUST
FOLLOW BEFORE YOU MAY : BRING ANY LEGAL ACTION FOR AN ALLEGED
CONSTRUCTION DEFECT. SIXTY DAYS BEFORE YOU BRING ANY LEGAL ACTION, YOU
MUST DELIVER TO THE OTHER PARTY TO THIS CONTRACT A WRITTEN NOTICE,
REFERRING TO CHAPTER 558, OF ANY CONSTRUCTION CONDITIONS YOU ALLEGE ARE
DEFECTIVE AND PROVIDE SUCH PERSON THE OPPORTUNITY TO INSPECT THE ALLEGED
CONSTRUCTION DEFECTS AND TO CONSIDER MAKING AN OFFER TO REPAIR OR PAY FOR
THE ALLEGED CONSTRUCTION DEFECTS. YOU ARE NOT OBLIGATED TO ACCEPT ANY
OFFER WHICH MAY BE:MADE. THERE ARE STRICT DEADLINES AND PROCEDURES UNDER
THIS FLORIDA LAW WHICH MUST BE MET AND FOLLOWED TO PROTECT YOUR
INTERESTS.
Installation 11.10
f
DocuSign Envelope ID:B2DADF5A-62BF-438F-AA69-2886CF1 FAD20
1.INCORPORATION:The parties agree that the terms and provisions set forth on the front page are incorporated into this contract by reference.
2.JOB SPECIFICATIONS:The specifications for the System are set forth in the work order attached hereto and incorporated herein by reference.
The contract price set forth on the front page shall include i) the purchase of the System described in the work order; ii) the installation of the
System by Seller or its subcontractor, and iii) costs of supplies and materials used in the installation of the System. Buyer agrees to be fully
responsible for all sales taxes,if any,levied in connection with the purchase and installation of the System.Unless otherwise set forth in this contract,
the installation shall occur at the address of Buyer stated in the preamble.It is the obligation of the Buyer to provide Seller or its subcontractor utility
services so that Seller may properly install the System.
3.SERVICE AGREEMENT:Buyer agrees that this is not a contract governed under Chapter 672,Florida Statutes, as this is a contract primarily
for the installation of the System.Seller is not responsible for securing for Buyer any Federal Tax Credit,State or Power Company rebate,if any.
4.RESTOCKING FEE:Except for instances caused by US Solar Squared,LLC,US Solar Squared,LLC will charge the customer a restocking fee
of 15%for any cancellations after the recession period ends.
5.FINANCING:If Buyer does not have the funds readily available to pay the contract price following the installation of the System,Buyer agrees to
apply to a financing company to pay the contract price on forms provided by the financing company. Such application shall be undertaken by Buyer
independent of Seller whom Buyer agrees is neither Buyer's agent nor the agent of the financing company in connection with any loan application.if
Buyer applied for financing in connection with this contract, Buyer understands that Seller will not accept Buyer's offer unless the financing is
approved by a duly licensed financing institution in good standing in the State of Florida.If Seller accepts Buyer's offer and thereafter learns that the
financing has not been issued,or if issued is then withdrawn by the financing company, Seller may terminate this contract without any liability to
Buyer.
6.WARRANTY: Seller agrees,on condition that the full contract price has been paid on completion of the installation of the System,to warrant the
operation of the System for one year following its installation.If,during this one year period,the System or any its components should fail to operate
in accordance with the manufacturer's specifications, Seller agrees to replace or repair the System at its sole cost and expense, including parts,
supplies and labor.US Solar provides a 10 year Workmanship Warranty and a 5 year Roof Penetration Warranty.
7.LIMITATIONS OF WARRANTY:The warranty of repair and replacement given by Seller in paragraph 5 above shall be null and void if Buyer
or anyone else shall damage or improperly maintain or operate the System, or should injury or damage be caused the System by fire,rain, freeze,
storm (including hurricane)or any other force majeure or act of God. Furthermore,Buyer acknowledges and agrees that the proper maintenance and
operation of the System is dependent upon the conditions of proper design,construction and maintenance of Buyer's property and building(and pool
if applicable)where the System is to be installed and operated,and that the plumbing and electrical services serving Buyer's property are adequate to
maintain and operate the System as intended once installed. If the System fails to operate within the manufacturer's specifications because of the
failure of any of these conditions, then the warranty of Seller is null and void. Furthermore, it is specifically agreed that SELLER DOES NOT
PROVIDE AN IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AS TO THE
SYSTEM BEING INSTALLED.
8. LIMITATION OF LIABILITY:The exclusive obligation and liability of Seller, and that of its officers,subcontractors,agents and employees,
to Buyer for any direct, indirect or consequential damages arising from or related to i) the failure of the System to operate according to the
manufacturer's specifications, or ii) damage to the property or building of Buyer due to a defect in the System or to the negligent or improper
installation of the System, or iii) for any personal injury (including death) caused Buyer by a defect in the System or its improper or negligent
installation is limited to the contract price;and,except to that extent,the Buyer hereby releases,discharges and waives any other claim or demand for
damages, injuries or losses of any kind or nature, or any other suit or action that Buyer may or does have against Seller, or any of its officers,
employees or agents,based upon a defect in the manufacture, installation or operation of the System, including any claim, demand, suit or action
Buyer might or could make or bring for the negligent installation of the System by Seller and its officers, subcontractors, agents and employees.
Furthermore, neither Seller nor any of its officers, subcontractors, employees or agents, shall be liable for any damage caused to the building or
property of the Buyer during the installation of the System unless Buyer serves written notice on Seller of the alleged damages within five(5) days
following installation.
9.ARBITRATION:Any dispute arising under or related to this contract, including any tort action arising out of or related to the installation of the
System,shall,if not resolved by the parties,be referred to binding arbitration.Only a court of competent jurisdiction shall have the right to determine
if the subject matter of the proposed arbitration comes within the terms of this arbitration provision if the parties disagree as to the arbitrability of the
matter. Arbitration shall be conducted in the Hillsborough County, Florida in accordance with Commercial Arbitration Rules of the American
Arbitration Association then pertaining, and judgment on any award rendered in such arbitration may be entered in any state or federal court. The
parties agree to allow the American Arbitration Association to choose the arbitrator,and its decision as to the selected arbitrator shall be.binding
unless either party can show the chosen arbitrator to be incompetent or biased for or against any party.Notices in connection with such arbitration
must be served by personal delivery or certified mail, return receipt requested, on Seller at its address stated on the front page hereto. Costs of
arbitration, including the filing costs and related arbitrator fees, shall be awarded as determined by the arbitrator; but only a court having
jurisdiction over the parties may make a determination whether attorneys fees are recoverable, and if so, in what amount. Notwithstanding the
foregoing,the parties hereto,and those in privity with the parties hereto,agree that any action or suit to foreclose a mechanics lien brought pursuant to
Chapter 713,Florida Statutes,shall be exempt from the application of this arbitration agreement.
10. MERGER:This contract, if accepted by Seller,represents the final expression of the representations,terms and covenants of the relationship
established between Seller and Buyer and the installation of the System. Buyer agrees that Buyer is not relying upon any other representation or
statement made heretofore by any sales agent,independent contractor or representative of Seller to Buyer as an inducement to enter into this contract,
and Buyer releases Seller from any other inducement or representation that is not included herein,even if such representation was material to Buyer's
decision to enter into this contract.Buyer agrees that only an officer or member of Seller has the authority to bind Seller to this contract,or waive or
modify any of its terms.Furthermore,Buyer understands and agrees that no sales agent,independent contractor or employee of Seller has the right to
promise Buyer that any rebate of any sort will be made or given with respect to the purchase or installation of the System.
11.GOVERNING LAW,VENUE:This contract is to be construed under and governed by the laws of the State of Florida.Any action,suit or other
proceeding between the parties hereto, whether or not such action, suit or proceeding arises under this contract, shall be brought in Hillsborough
County,Florida; and the parties agree to waive venue in any other county.However, if the suit or action includes a mechanic's lien foreclosure,
venue shall be placed in the county where the System was installed.
12. NON-ASSIGNABILITY:Buyer may not assign this contract,nor any of Buyer's rights hereunder,to another.
13. PAYMENT:Buyer agrees to pay the full contract price on completion of the installation of the System,time being of the essence.
14. DEPOSIT:If the work order given in connection with this contract provides for Buyer to give Seller a deposit as a condition of Seller accepting
Buyer's offer, Buyer shall have the right to withdraw its offer if the amount of the deposit is not agreeable to Buyer. Payment of the deposit to
Seller's employee shall be conclusively deemed Buyer's agreement to enter into this contract and pay the deposit. Despite accepting such deposit,
Seller shall not be obligated to apply for any permit within thirty days of accepting the deposit or commence work within 90 days of the permit(s)
being issued,and the parties hereto waive application of Florida Statute§489.126(2)to the extent it applies to this contract,if at all.
M. ACCEPTANCE: if-Seller does not provide notice to Buyer that Seller has accepted Buyer's offer within forty days following the date Buyer
signs this contract,Buyer's offer to enter into this contract shall expire.However, should Seller proceed to install the System following ezpuation of- ——
the acceptance period with Buyer's knowledge and approval,then the parties hereto shall be bound by the terms of this contract.
Installation 11.10
INSTR#2021028124 OR BK 1 0277 PG 1 878 Page 1 of 1
02/11/2021 07:33 AM Rcpt:2259839 Rec:10.00 DS:0.00 IT:0.00
Nikki Alvarez Sowles,Esq.,Pasco County Clerk&Comptroller
-lJFWniiiDW �++
Jr
. . iMlfel�l
,
:r
`r
:.1 ''., ;;tiaex�iglgtqilt MYats�N4n<ihst� k� ii "
l
yt "'
,
_ vl
!='rt
"• C
•
"xAM}YTIOlW.1�D^=''
- _,Rf:..':•:::x ..: tav�;�V�v� TT}I`+�!i.:1.�� .'�^T,.'?Y,�':rllw!n;i+n}v^":�:an}+w
�7131�lM)(j);!!A7d1F+rdllr"[,
�b!i1:fiMwl.a4.1 ,777 7-7
'
-- ��t�6iTAl�?Cga.1�'>�1�10�" �lIdio„M�}plaitl:R19.`78{!�i►?.".�;Ia1Sd�,Ek�i4:
eta::.-,....... .-
'.Cyerr
t�wNM►" `i�i::d' i+l►ti;>pid1M0}r;- _
- _ �"'
" � J ''.
WflFI'1' lti„ : ICES .,-;.wo:._:- .'
tkWM a[ l4Mtet;I:lfalatll ±io4dtap�iplti� rfi±�liMslirilblid,�tf�iilliei'�iiofl�if;r:
:'o».1t�^..qa!!!�t�iGi+ .1►.�.�A�'!?M�!!y�pfe�.: `;?�K� :u:?ga�+:. M�e �' •`3 � �+
'``'��"' ''y�y� /gyp �{�� '•�''..',.�':
4"
H
� IQf1:Eic �!
Y+'' -- �tilrtlfeb
1JIIQ�f:•: •..'�
n.
..:. .... ..- '-....::'.': ... ..':..: fit.
9.6kW SOLAR ARRAY PANS
FOR PROJECTMODULES S -DESCRIPTION:
SOLAR: MSE320SR8T GENERAL NOTES: "�
30 INVERTERS - ENPHASE: IQ7-60-2-US 1. THIS IS TO CERTIFY THAT TO THE BEST OF
J OS E P H P 0 W EL E MY KNOWLEDGE AND BELIEF, THESE PLANS
CONFORM WITH FLORIDA BUILDING CODE 2020
GOVERNING CODES: WITH ALL SUPPLEMENTS AND ADDITIONS. •• p
2020 FLORIDA PLUMBING CODE, 7TH EDITION 2. ALL PRODUCTS TO BE INSTALLED PER
3107 NUBBIN RIDGE LN S'•,
2020 FLORIDA BUILDING CODE, 7TH EDITION MANUFACTURER'S WRITTEN SPECIFlCATIONS.
2020 FLORIDA MECHANICAL CODE, 7TH EDITION
Z E P HYR H I DES, FL0 R DA 33540 L NFPA 1 2018 ANDREW D. HALL PT CHAPT AN ENGINEER
NEC 2017 LICENSED PURSUANT TO CHAPTER 471, CERTIFY
THAT THE PV ELECTRICAL SYSTEM AND
ELECTRICAL COMPONENTS ARE DESIGNED AND
APPROVED USING THE STANDARDS CONTAINED IN
THE MOST RECENT VERSION OF THE FBC, FBC
107.
TYP. EAVE Wind Design Data
Wind Speed 140 mph
Risk Category II
Exposure C
Gust Factor ±0.18
"A"Dimension 5.1 ft
Roof Pressure for Components and Cladding
Zone 1 16.47 psf -25.65 psf
Zone 2 16.47 psf -44.55 psf
Zone 3 16,47 psf -66.15 psf
.3' MIN. TYP
OBSTRUCTION MISSION SOLAR: ?
MSE320SR8T (TYP)
ALL WORK SHALL COMPLY WITH PREVAILING
CODES FLORIDA BUILDING CODE
NATIONAL ELECTRIC CODE,
AND THE CITY OF ZEPHYRHILLS
ORDINANCES
TYP. RIDGE DRIVEWAY
REVIEbv 1J,. JAR AR 1 1 2021
CITY OF ZEPHY
PLAN EXAMINE
DRAWING INDEX:
S-1 COVER
S-2 ARRAY LAYOUT & DETAILS
DISCONNECT S-3 ELECTRICAL
MIN. 4' CLEARANCE S-4 NOTES
PER NEC 110.26(A) S-5 SPECIFICATIONS
MODULE ROOF LAYOUT 'YP. EAVE S-6 SPECIFICATIONS
NTS S-7 SPECIFICATIONS
S-8 SPECIFICATIONS
,
S q
QMR—UMC
PV MODULE ell
CLIP
QMR
3/8 -16 X 3/4" HEX HEAD BOLT ;O CROSSRAIL LIGHT
3/8" - 16 FLANGE NUT (TYP)
SUNMODO NANO SUNMODO NANO
RAFTER MOUNT QMR RAFTER MOUNT
(TYp) CROSSRAIL LIGHT (TYP)
TOP VIEW
EXISTING UNDERLAYMENT NTS
EXISTING ROOF TRUSS
V1/2" PLYWOOD
5/16" DIA SS LAG SCREW
/2-1/2" EMBED MIN. TYPICAL SHINGLE ROOF ATTACHMENT
NTS
QMR-UMC CLIP
SUNMODO NANO RAFTER MOUNT 48" MAX. O.C.
(TYP) (TYP) QMR-UEC CLIP
(TYP)
w „
QMR-UEC MISSION SOLAR: MISSION SOLAR:
MSE320SR8T QMR-UMC CLIP MSE320SR8T
(np) (TYP) (TYP) (TYP) Q w
Ma-
afV)
w
QMR-UMC CLIP QMR-RL14 (TYP) QMR-UEC CLIP
SUNMODO NANO RAFTER MOUNT (TYP) TYPICAL LAYOUT (lP)
(lip) NTS
v � • h
cif
#4
#6 THWN-2 (3 CONDUCTOR) NOTE:
3/4" EMT, FMC, FOR EXTERIOR ALL INVERTERS ARE EQUIPPED
APPLICATION USE PVC OR W/ INTERNAL RAPID SHUTDOWN
LFMC/LFNMC CONDUIT #6 THWN-2 (3 CONDUCTOR) SYSTEM PER NEC 690.12
3/4" EMT, FMC, FOR EXTERIOR
LOCKABLE FUSED APPLCATION USE PVC OR
PV AC DISCONNECT LFMC/LFNMC CONDUIT ENPHASE Q CABLE MISSION SOLAR: MSE320SR8T
60A 240V 2-POLE #10 THWN-2 (3 CONDUCTOR) ENPHASE Q CABLE Q-12-10-240 W/ ENPHASE IQ7-60 2 US
40A RK-1 FUSE 3/4" EMT, FMC, FOR EXTERIOR Q-12-10-240 (.�,P) INVERTER
APPLCATION USE PVC (TYP)
OR LFMC CONDUIT
N L2 L1
AC ' AC
METER DC DC
L1 L1
L2 L2 NO._1 NO. 15
N N SPACE 20
20I : 4
MR-RL14 (TYP)
SPACE I 20
f dJ 20IL ) : E _ _ NOTG NO. 1 NO. 15 ALL STRINGSTO HAVE
#6 THWN-2 G AC AC TERMINATORS & SEALING CAPS
DC DC INSTALLED PER MANUFACTURER'S
40 SOLADECK COMBINER BOX SPECIFICATIONS
NEUTRAL GROUND 600V/ NON-FUSED
OR
SOLTECTION RESIDENTIAL
TRANSITION BOX ENPHASE Q CABLE MISSION SOLAR: MSE320SR8T
Q-12-10-240 W/ ENPHASE IQ7-60-2-US
GEC BOND AT
ENPHASE IQ COMBINER PLUS RACKING SYSTEM (lP) INVERTER
W/ (2) 20 AMP BREAKER (SEE NOTE #2)
NEUTRAL GROUND
AC PANEL 200 AMP/240V
6/® h
O •
NOTES:
1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT
MODULE SPECIFICATION INVERTER SPECIFICATION SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND i3O •
MODULE MAKE MISSION SOLAR INVERTER MAKE ENPHASE STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION.
2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43.
MODULE MODEL MSE320SR8T INVERTER MODEL IQ7-60-2-US
3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D).
FSEC CERTIFICATION II MAX AC POWER OUTPUT 250 VA 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS
PMAX (STC) 320 w MAX. INPUT VOLTAGE 48 V RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE
VOC (STC) 40.80 V NOM. DC VOLTAGE @ 240V 240 V ITEMS IDENTIFIED IN NOTE 1.
VMPP (STC) 34.22 V NOM. AC VOLTAGE 16-48 V 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING
MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING-ELECTRIC SHOCK HAZARD - DO
ISC (STC) 10.03 A MAX. CONTINUOUS OUTPUT CURRENT 1.00 A NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN
MAX. DC CURRENT 15.0 A
IMPP (STC) 9.35 A POSITION OR EQUIVALENT.
NOCT 46 C MAX. DC POWER (STC) 350 W 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON
IC ISC 0.039 %/C CEC EFFICIENCY 97 % THE PREMISES AT SERVICE ENTRANCE.
TC VOC -0.280 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12.
TC PMPP -0.377 %/C 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION.
9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED
OPERATING TEMP. -40-+85 C TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE
HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO
3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED Al THE HIGHER AMPACITY, WHICH EVER IS LESS.
AN
NEC 310.15 (B)(2)
SAFETY LABELS AND MARKINGS GENERAL NOTES: N EMERGENCY CONTACT 10.ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE
NEC.
1. EQUIPMENT SUCH AS INVERTERS AND SOLAR MODULES HAVE U S SOLAR 12.PV ARRAY INTERCONNECTION TO BE MADE WITH BACK-FEED BREAKER.
PRE-APPLIED LABELS FOUND HEREIN SHALL BE APPLIED TO SUCH 13.GFI BUILT IN TO ALL INVERTERS.
EQUIMSES.
2. LABELSE AND NT FMARKINGS OR MSHALL BE APPLIED ATIONAL O TO COMPONENTS IN 1 -813-43 4-0284
ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC.
3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV
RESISTANT OUTDOOR-RATED LAMINATED VINYL IN ACCORDANCE WITH
ANSI Z535.4-201 1.
SAFETY LABELS AND MARKINGS LEGEND
A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN
SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT
POCC.
MAIN SERVICE DISCONNECT MARKING CAUTION SOLAR PHOTOVOLTAIC SYSTEM
A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE ® -WARNING-
DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT THIS SERVICE IS SUPPLIED BY MULTIPLE -WARNING- ELECTRIC SHOCK HAZARD.THE DC
CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH SOURCES. SEE DISCONNECTS BELOW. AUTHORIZED PERSONNEL ONLY CONDUCTORS ARE OF NGR NDD DAIC
SYSTEM UNGROUNDED AND
WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A RATED AC CURRENT: 37.5AMAY BE ENERGIZED
/ NOMINAL AC VOLTAGE 240V AUTHORIZED PERSONNEL ONLY
NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." -
THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER LOCATION: MAIN PV PANEL LOCATION: DISCONNECTS, INVERTERS,
JUNCTION BOXES, OTHER ENCLOSES
RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. HOLDING DC CONDUCTORS
w�twY
CIRCUIT DISCONNECTING MEANS MARKING
A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT PHOTOVOLTAIC DISCONNECT
BREAKER CONTROLLING THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM
ELECTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. /4\ _
THE LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL LETTERS AT -WARNING-
LEAST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: ELECTRIC SHOCK HAZARD I PHOTOVOLTAIC SYSTEM EQUIPPED
"PHOTOVOLTAIC DISCONNECT." THE LABEL SHALL BE CONSTRUCTED OF DO NOT TOUCH TERMINALS. TERMINALS ON WITH RAPID SYSTEM SHUTDOWN
BOTH THE LINE AND LOAD SIDES MAY BE
DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL.
ENERGIZED IN THE OPEN POSfDON.
LOCATION:AC DISCONNECT(S)
*• N�
PER.C 60 CLASS. LEADING 15- 2 .` .
Enphase IQ 7 and IQ 7+ Microinverters �•,,si '
Electrical Parameters at Standard Test Conditions(STC) INPUT DATA(DC) 107-60-2-US IQ7PLUS-72-2-US
Modu'e Type MSE31:5S1t9T M5E320SR87 MSES2SSR8T IEC Commonly used module pairings" 235W-350 W+ 23°,W-440W+
Power Output Pmax wp 315 320 325 61215-61730-61701-Salt mist Module compatibility 60-cell PV modules only 6u-cell and 72-cell PV modules
Module E:fflr ertcy ry 18.65 13 4a ;9.24 Maximum Input tae voltage 18 a f.-:u
UL ., Peak power tracking voltage 27V-37V 27V-45V
Tolerance 0-+3% 0'+3% 0-+3% UL 1703 listed Operating ranrje 16 V-48 V 16 V-613 V
Short-Cline Current 11p. A 9.997 10.025 10.060 ._..............................................................._.................................................................................... Min/Max start voltage 22V/48V 22V/60V
Open Circuit Voltage Voc V 40.44 40.80 41.14 A)-, CEC Max CiC shore ciroult current(rrnodule Ise) 15 A 15A
Rated Current Imp A 9253 9.351 9287 121155 _. Overvoltageclass DC port 11 11
Rated Voltage Vmp V 34.04 34.22 34.62 DC port bac.trfeed current 0 A 0 A
PV arrcy configuration 1 x 1 ungrounded array;No additional DC side protection required;
Fuse Rating 20 28 20 AC side protection regt•ires max 20A per branch circuit
OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter
Peak output power 2.i4 VA 2951/P
MSES20SR$T:320WP,60 CELL SOLAR MODULE Maximum continuous output power 240 VA 290 VA
[normal Operating Celt Temperature(NOCT) 4609°C(t2°C) CURRENT-VOLTAGE CURVE Nominal(1-1)voltagetrangep 2.40 V(
211-264 V 183-229 V 2112641/ 183✓229V
Temperature Coefficient of Pmax -0.377%/°C
22 ;.. -- -- .. -- --..---- .. ------ Maximum continuous output current 1.0 A 1,15 A 1.21 A 1.39 A
TempeeratureCosiiftclentofVcc -0.20%1°C i cels'remp.=25'c Nominalfrequery 60Nz Ggttr
Temperature Coefficient of lac 0.039%!°C lu - .•. ..In4den,....rrrd, a000.W/m2.. ..... ............ .... — -— Extended frequency range 47-68 Hz 47-68 Hz
-.. i.. ..........Incutent .., . z.......... ........:.. ...........,..,
AG short circuit fault current over 3 cycles 5.$Arms 5.8 Arms
Iced:=.See..W/m
G a Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(240 VAC)
v 1 13(208 VAC) 11(208 VAC)
5.?- .-..Incident ...tl'.C+t. 4fZQ WIn11..
Maximum System Voltage 1,000VdC t j 0eedvoltdge r iaat AC trort Iii ill
Operating Temperature Range -40°C(-40°F)to+85°C(185°F) a, ncidnt.................W/m2.... AC port backfeed current 0 A 0 A
1.f3 Power factor
Maximum Sergi Fuse Ratin nd. Power factor(adjug 20A incident. I =200 W(m2. (adju 1 Liz ..... stable) 0.71eading...0.71agging 0.71eading...0.71agging
Fire Safety Classification Type 1,Class C EFFICIENCY @240 V @208 V @240 V @208 V
6631 Pa(117 pef) t.--..... ... .. ...... Peak CEC efficiency 97!,% 07 4 . 97.5% 97.3 r
Front&Back Load(kit starndard) Tested to UL1703 standard 0 10 a . 02
CEC weighted efficiency 91.0' 9/0% 91.0% 97.0
Hail Safety Impact Velocity 25mm at 23 m/s Voltage M MECHANICAL DATA 10 7 Microinverter
Current-voltage characteristics with dependence on irradiance — —- --
e €,.
and module temperatureAmbient temperature range -405C to*65°C
Relative humidity range 4%10 100%(condensing)
Solar Culls F•type mono-crystalline sifioon (158.75mm) Connector tySe MC4(or Amohenol H4 UT?(with additional O-DCC-5 adapter)
Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket)
Cell Orientation 60 cells(6x10),5 busbar BASIC DESIGN(UNITS:mm)
1Cx7t1rnm x 100$mm x 40mra ight 1.08 kg(we 2 3B Ibs)
Module Dimension eee
(6528 in x 39.66 in x 1.58 h1) Cooling Natural convection-No fans
Weight 20 kg(441b) t; u5 Approved for wet locations Yes
Pollution degree PD3
3,2mm(0.12.6 h.)tempered,
1rroM Glass aw ,'TJ Ericloeure Class 11 double insulated,corrosion resistant polymeric enclosure
III 11111111111 IllIllIllIllIllI I iiimv-kort≥anti-reflective rotrting l
""' r Environmental category/UV exposure rating NEMA Type 61 outdoor
Frame Anodized aluminum alloy av FEATURES
raw ...-......... -------- ...........�,_.... ..........,,...... .. .__.,_...._ ...
lEncapsulant #hyiarte yt ocelots(E1fA) a,°Sae r emmunicat .__-_---• .fon Power Line Communication(PLC) -,.-,.,.-......-...._.-. _.. _ _
i
J-Box Protection class IP67 with 3 bypass-diodeslElifihil Ill II iiiioi IMonitoring Enlighten Manager and MyEnlighten monitoring options.
'°'° Il11ItII11IllltlIItHItltttlltIfl1 rule
Both options require installation of an Enphase IQ Envoy.
Cables °"wire,Im(39.37 In.),4mma/12 AWG wH Disconnecting means The AC and µC connectors have been evaluated ano approved by UL for use as the load-break
Connector MC4 Compatible disconnect required by NEC 690.
'a Compliance CA Rule 21(UL 1741-SA)
to_ UL 62109-1,UL1741/1EEE1547,FCC Part 15 Class B,ICES-0003 Class B,
CAN/CSA-C22.2 NO.107.1-01
M This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
Container FT Pallets Panels 3$O W11111 ii III IJ[II 111111111111IIIII F ° NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC
908 and DC conductors,when installed according manufacturer's instructions.
53' Double stack 36 936 299.52 kW Front View Back View 1.No enforced DC/AC ratio.See the compatibility•calculator at ttttvsNenhav s
,.e.ssmien-us, llR.P.s2r11n1Q.S1uiB:S4mF-atllriiitY.
4D Dottie stack 28 728 232.96 kW 2.Nominal voltage range can be extended beyond nominal if required by the utility.
3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area.
Panels Weight Height Width Length L3
Pallet 25 1,1g81bs 42.45° 45.50" 67.00' rlearn To more about Enphase offerings,visit enphase.com EN PHASE
MISSION SOLAR J O2018 Enphase Err-rgy.A I rights rescr ved.All tradernr.d s or brands used arc the propcity of Enphase Fsergy,Inc
ENERGY 2015-32-C8
Mission Solar Energy reserves the right to make specification changes without notice Mission Solar Energy 18303 S.New Braunfels Ave.,San Antonio,Texas 78235
oxuarervsa:aNtiz-te.sco:s r.'!IS,xrr:n2 fvi.swrar u2v.sss
infoCmissionsolar.com I www.missionsalar.com
ee
N.
�� q)
e S ��
9,eg
Enphase Q Cable Accessories Enphase IQ Combiner 3
MODEL NUMBER
Q AGGREGATOR SPECIFICATIONS 10 Combiner 3 — ��._.._ IQ Combiner 3 with Enphase€Q Envoy"printed circuit board for integrated revenue grade P
- X-IQ-AM1-240-B production metering(ANSI 012 20+/-0.5%)and optional*consumption monitoring i+1-2.5%).
r ggregatcr U BA 3-1P-FO{stnrle-t'hasff}.Corr,b ines rip to th ntaicsuinuerier branct;es into came twine run,
Protect with maxirn•um 60 A,2pole
ACCESSORIES and REPLACEMENT PARTS(not included,order separately}
QuPt)-
0 commercial Aggregator Q-BA-3-3P-35(three-phase).Combines up tothre,.single-phasemicroinverterbranchesintoathree- Enphase Mobile Connect"
phase.home run.Protect with maximum 40 A,3-pole OCPD. CELLMODEM 03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60
CELLMOD:EM-.ill(3G/5-year data plan) tnicroinaerters,(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin islands,
Dinpensions 140 mm(W)x227 mm(D)x 80 mm(H)[7.5 in(W)x 9 in(f))x?.2 in(H)) CELLMODEM-M1(4G based LYE-MIS-year data plan) where here is adequate cellular service in the installation area.)
Homerun conductor size range #12 to#4 AWG Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%).
CT-200-SPLIT
T.-
Enclosure rating NEiiAA3(up to 45'from n4rivk)iMal) _ 'Ccnlumpiion monitoring isrecui•ed for Enntiase Storage:systems
Temperature range 40°C to+55'C(4Q°F to+122°F) Wireless USS adapter Installed at the IQ Envoy.Farr communications with Enphase Encharge<storage and Enphase
COMMS-KCT 91 Enpowet"smart switch.Includes USB cable for connection to 1Q Envoy or Enphase IQ Combiner
Compliance UL1741(assembled product)and UL6/03(bulkhead connectors) and allows redundant wireless communication with Encharge and Enpower.
Circuit Breakers Supports Eaton 8R210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers.
CONDUCTOR SPECIFICATIONS BRK-1 DA-2-240 Circuit breaker,2 pole,l GA,Eaton BR210
CerliSeetion 1Ji.:IOXI(r a v.,sable).UL 9703(cable asscmblien).DG cat;ie BRK-15A-2-240 Circuit breaker,2 pole,l5A,Eaton BR215
BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220
Flame test rating FT-0
kPLC-01 Power line carrier(cnrturstuiication bridge pair)),quantity one pair
Conductorte Ro1H8,OIL 8£51,CE UV resistant,combined UL for the United States XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01)
Conductor type THHN/TH W N-2 dry/wet
Dscenrwcting means The AC and AC buihead connectors have been evaluated and approved by UL for use as the load-break XA-t IdV-PCESA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3
disconnect required by NEC 690. ELECTRICAL SPECIFICATIONS
Q CABLE TYPES/ORDERING OPTIONS Rating Continuous duty
Model Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box System voltage 120/240 VAC,60 Hz
Q 12-10-240 277 VAC 1.3 m(E-2 it) Pc3tt'alt 240 Eaton BR series bulbar rating 125A
01217-240 277 VAC 2.0 m(6.5 ft) Landscape(60-cell) 240 Max.continuous current rating(output to grid) 65 A
0-12-20-200 277 VAC 2 3 m(7.Sft) Landscape(/2-cell) LrIii Max.fuselcirciuit rating(output) 9r}A
ENPHASE 0 CABLE ACCESSORIES Branch circuits(solar and/or storage) Up to tour 2-pole Eaton BR series Distributed Generation(DG)breakers only(nct included)
Name Model Number 0escri pit en Max.continuous current rating(Input from PV) 64 A
Raw0 Cable Q-12-RAW-200 300 meters of 12 A G cable with no conneciore Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included
Field-wireable connector(male) Q-CONN-10M Make connections from any Q Aggregator open connector Production Metering CT 200 A soli core pre-installed and wiredto 10 Envoy
Field-wireable connector(female) O-CONN-10F Make connections from any C Cable open connector MECHANICAL DATA
Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Dimensions(WxHiD) 49.5 5x375 5 x 16.8 cm(19.5"x 14.75`x 6.83)•Height is 21.06°(53-5 em with rxwuntng brackets).
Disconnect tool 0 4)150-10 Disconnect:tot for Q Cable connectors,DC ccrrrieotors,and AC module mount Weight 7.5 kg(16.5 Ibs)
Q Aggregator sealing caps(male) O-BA-CAP-10 Sealing cap for unused aggregator connections Ambient temperature range -4p C m+4trp C(-40°to 115'F)
Q Cable sealing caps(female) Q-SEAt-1R One needed to cover each unused connector on the cabling Cooling Natural convection,plus heat shield
Terminator 0-TERM-i0 Terminator cap for unused cable ends Enclosure environmental tatloig Outdoor.NRTI;certlfled,NEMAlype 3R,pulycarbonete€onstruction
Replacement 130 Adaptor(MC4; Q-DCC-2 DC adaptor to MC4(nuts voltage 1170 VDC) Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors
60 A breaker branch Input:4 to 110 AWG copper conductors
Replacement DC Adaptor(UTX) Q-DCC-5 DC adaptor to UTX(max voltage 100 VDC) Main lug combined output: 10 to 2/0 AWG copper conductors
Neutral and ground: 14 to 1/0 copper conductors
Always follow local code requirements for conductor siz ig.
TERMINATOR SEALING CAPS Altitude' To2o00 meters(6,560feet)
Terminator cap for oftunused cable Sealing caps INTERNET CONNECTION OPTIONS
ends,sold in packs often and cable connections -- - — - - -
(QTERM-10) (C-BA-CAP-10 and 0-SEAL-IC) Integrated Wi-F' 802.11b/g/n
Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included)
DISCONNECT TOOL CABLE CLIP Ce i,rlar Optional,CEt LMODEM•01(3G)or CFI LMODFM-03(4C)or CELLMODEM-MI(4G based i TF-M)
(not included
Plan to use at least one per Used to fasten cabling to the racking COMPLIANCE
installation,sold in packs often or to secure looped cabling,sold in -------"--'-'---- -- —.
(Q-DISC-1fl) packs of ten(Q-CLIP-100) Compliance,Combiner UL 1,41,CAN/CSA C22.2 No.1G7,l,47i, art I5,Class B,ICES 003
Production metering:ANSI 012.20 accuracy class 0 5(PV production)
Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 N.o.61010-1
To learn more about Enphase offerings,visit enphase.com
To learn more about Enphase offerings,visit enphase.com to 251.3 r:erhaou tear,;.Al riy!s rosaaed.Enphoso,the Enia:ase logo,iQ Combiner 3,and other trademarks or service somas are the
O 2018 Enphase Etcrgy.NI nigh,,reserved.All trademarks or brands used are its property of Enphase Energy.Inc eE N R H AS E. :aamar"^ai Er�p€use Strain,ac. EN P H AS E.
^<078Cn-p3 2{�
SUNMOO*
J
`IA Oil
l��ll
5 levels of protection against Aesthetically pleasing
unibody aluminum cast
r • water penetration construction
■
360-degree positioning,
serrated surface on both.
ATTACHMENT
sides for rail mounting
■ ■ ■
Versatile mounting option
includes direct-to-decking
for fast installation
• • ',
r -
Integrated Ultra Soft
Weather Resistant
silicone gasket
Alignment markers
The NanoMount Advantage enable easy installation
' ° " ` ` ` ° ` - ",f The fastest roof attachment in
« • - solar
Versatile mounting options
including direct-to-decking
• a 5 0 O
■ ,� - - $ . / Eliminates the need to lift
shingles and prevents damage to Application Composite shingle and rolled asphalt
shingle Material High grade aluminum, 304 stainless steel hardware
• S '/ High-Velocity Hurricane Zone Finish Black powder coating
. ■ ■ o - - Approved - Passed TAS 100 (a) Roof Attachment Rafter and decking
_ _ , , _ Wind-Driven Rain Test
Structural integrity IBC and IRC Compliant
• 5 0 5 0 / All materials are com atible with
p Warranty 25 years
+ . • roof shingles
Sun•Modo, Corp. Vancouver, WA., USA a www.sunmodo.com • 360.844.0048 • info@s.unmodo.com
N c
A�AA cQuickMount PV
•
ii "r��r
ENG IT r RESPECT THE ROOF
ingenuity in En ineerin
Rail Spans for Quick Mount PV QRaiI Light System
Mean Roof Height: 0<h≤15 ft Panel Orientation: Portrait
Table 3 Roof Angle: 7<0 ≤27 degrees
Exposure Category: C
Roof Ground Wind Speed(mph)
Wind Snow
Zone Load 100 110 115 120 130 140 150 160 170 175 180 190
0 81 81 81 81 81 76 71 b6 62 60 59 55
10 76 75 74 73 71 69 67 66 62 60 59 55
20 61 61 61 61 60 59 58 56 55 55 54 53
30 52 52 52 52 52 52 51 50 50._ 49 49 48
Zone 40 45 45 45 45 45 45 45 45 45 45 45 44
1 50 41 41 41 41 41 41 41 41 41 41 41 41
60 38 38 38 38 38 38 38 38 38 38 38 38
70 35 35 35 35 35 35 35 35 35 35 35 35
80 33 33 33 33 33 33 33 33 33 33 33 33
90 31 31 31 31 31 31 31 31 31 31 31 31
0 78 70 67 64 59 55 51 48 45 43 42 40
10 76 70 67 64 59 55 51 48 45 43 42 40
20 61 61 61 61 59 55 51 48 45 43 42 40
30 52 52 52 52 52 52 51 48 45 43 42 40
Zone 40 45 45 45 45 45 45 45 45 45 43 42 40
2 50 41 41 41 41 41 41 41 41 41 41 41 40
60 38 38 38 38 38 38 38 38 38 38 38 38
70 35 35 35 35 35 35 35 35 35 35 35 35
80 33 33 33 33 33 33 33 33 33 33 33 33
90 31 31 31 31 31 31 31 31 31 31 31 31
0 62 56 54 52 48 44 41 38 36 35 34 32
10 62 56 54 52 48 44 41 38 36 35 34 32
20 61 56 54 52 48 44 41 38 36 35 34 32
30 52 52 52 52 48 44 41 38 36 35 34 32
Zone 40 45 45 45 45 45 44 41 38 36 35 34 32
3 50 41 41 41 41 41 41 41 38 36 35 34 32
60 38 38 38 38 38 38 38 38 36 35 34 32
70 35 35 35 35 35 35 35 35 35 35 34 32
80 33 33 33 33 33 33 33 33 33 33 33 32
90 31 31 31 31 31 31 31 31 31 31 31 31
Notes:
1. Tables are based on critical rail span for load combinations as specified in chapter 2 of the ASCE 7-10 and
allowable design loads per the 2015 Aluminum Design Manual.
2. Panels are assumed to be in portrait orientation with a maximum length of 67.5"
959 Larchmont Court,Aurora,IL 60504 3/4/2019
630-219-1997(P)
www.structuralenginuityinc.com C3
9. 6kW SOLAR ARRAY PLANS
No
PROJECT DESCRIPTION:
GENERAL NOTES:
FOR 30 MODULES MISSION SOLAR: MSE320SR8T
30 INVERTERS - ENPHASE: IQ7-60-2-US 1. THIS IS TO CERTIFY THAT TO THE BEST OF
JOSEPH P O •'
1 MY KNOWLEDGE AND BELIEF, THESE PLANS + •••
V J E L L CONFORM WITH FLORIDA BUILDING CODE 2020
GOVERNING CODES: WITH ALL SUPPLEMENTS AND ADDITIONS. �� F
10 7 N U B B N R D G E N 2020 FLORIDA PLUMBING CODE, 7TH EDITION 2. ALL PRODUCTS TO BE INSTALLED PER
3 2020 FLORIDA BUILDING CODE, 7TH EDITION MANUFACTURER'S WRITTEN SPECIFICATIONS.
2020 FLORIDA MECHANICAL CODE, 7TH EDITION I, ANDREW D. HALL PE# 87479 AN ENGINEER
Z E P H Y R H L LS, F LO R DA 335 40 NNEC FPA 2017
LICENSED PURSUANT TO CHAPTER 471, CERTIFY
1 2018
THAT THE PV ELECTRICAL SYSTEM AND
ELECTRICAL COMPONENTS ARE DESIGNED AND
APPROVED USING THE STANDARDS CONTAINED IN
THE MOST RECENT VERSION OF THE FBC, FBC
107.
TP. EAVE Wind Design Data
Wind Speed 140 mph
Risk Category II
Exposure C
Gust Factor ±0.18
"A"Dimension 5.1 ft
Roof Pressure for Components and Cladding
Zone 1 16.47 psf -25.65 psf
Zone 2 16.47 psf -44.55 psf
Zone 3 16.47 psf -66.15 psf
3' MIN. TYP
ISSION SOLAR:
OBSTRUCTION SE320SRST (TYP)
TYP. RIDGE DRI AY
DRAWING INDEX:
S-1 COVER
S-2 ARRAY LAYOUT & DETAILS
DISCONNECT S-3 ELECTRICAL
MIN. 4' CLEARANCE S-4 NOTES
PER NEC 110.26(A) S-5 SPECIFICATIONS
MODULE ROOF LAYOUT TYP. EAVE S-6 SPECIFICATIONS
NTS S-7 SPECIFICATIONS
S-8 SPECIFICATIONS
♦
NOTES:
1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT
MODULE SPECIFICATION INVERTER SPECIFICATION SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND
INVERTER MAKE ENPHASE STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. ,,�
MODULE MAKE MISSION SOLAR
MODULE MODEL MSE320SR8T INVERTER MODEL IQ7-60-2-US 2. ALL EQUIPM NTTS ALST BE E GROUNDED PER
D PER NEC (D). .
3. ALL EQUIPMENT SHALL LISTED PER NEC 690.4(0).
FSEC CERTIFICATION # MAX AC POWER OUTPUT 250 VA 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS
PMAX (STC) 320 W MAX. INPUT VOLTAGE 48 V RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE
VOC (STC) 40.80 V NOM. DC VOLTAGE ® 240V 240 V ITEMS IDENTIFIED IN NOTE 1.
5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING
VMPP (STC) 34.22 V NOM. AC VOLTAGE 16-48 V
MAX. CONTINUOUS OUTPUT CURRENT 1.00 A MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ 'WARNING-ELECTRIC SHOCK HAZARD - DO
ISC (STC) 10.03 A NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN
IMPP (STC) 9.35 A MAX. DC CURRENT 15.0 A POSITION OR EQUIVALENT.
NOCT 48 C MAX. DC POWER (STC) 350 W 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON
TC ISC 0.039 %/C CEC EFFICIENCY 97 7 THE PREMISES AT SERVICE ENTRANCE.
TC VOC —0.280 Y/c 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12.
TC PMPP -0.377 7./C 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION,
9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED
OPERATING TEMP. -40-+85 C TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE
HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO
3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS.
NEC 310.15 (B)(2)
SAFETY LABELS AND MARKINGS GENERAL NOTES: N AN V EM E R G EN CY CONTACT 10.ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE
NEC.
1 EQUIPMENTSUCH AS
INVERTERS
MODULES APPLIED TO SUCH U S S O BAR 12.PV ARRAY INTERCONNECTION TO BE MADE WITH BACK-FEED BREAKER.
PRE-APPLIED LABELS FOUND HEREIN SHALL BE
13.GFI BUILT IN TO ALL INVERTERS.
EQUIPMENT 2. LABELS FOR
ANDMARKINGSSHLBE APPLIED TO COMPONENTS IN 1 -81 3-44-0 2 8 4 3
ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC.
3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV
RESISTANT OUTDOOR-RATED LAMINATED VINYL IN ACCORDANCE WITH
ANSI Z535.4-2011.
SAFETY LABELS AND MARKINGS LEGEND
A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN
SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT
POCC.
MAIN SERVICE DISCONNECT MARKING \ CAUT ION SOW PHOTOVOLTAIC SYSTEM
A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE ® -WARNING-
THIS SERVICE IS SUPPLIED BY MULTIPLE ELECTRIC SHOCK HAZARD.THE DC
DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT -WARNING- CONDUCTORS OF THIS PHOTOVOLTAIC
CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH SOURCES. SEE DISCONNECTS BELOW. AUTHORIZED PERSONNEL ONLY SYSTEM ARE UNGROUNDED AND
WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A RATED AC CURRENT: 37.5A AUTHORIZED PERSONNEL MAY BE ERSON
ONLY
NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." NOMINAL AC VOLTAGE: 240V
LOCATION: DISCONNECTS, INVERTERS,
THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER LOCATION: MAIN PV PANEL JUNCTION BOXES, OTHER ENCLOSES
RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. HOLDING DC CONDUCTORS
P!ARRAY
CIRCUIT DISCONNECTING MEANS MARKING
A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT • PHOTOVOLTAIC DISCONNECT
BREAKER CONTROLLING THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM
ELECTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS.
THE LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL LETTERS AT -WARNING-
LEAST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: ELECTRIC SHOCK HAZARD PHOTOVOLTAIC SYSTEM EQUIPPED
"PHOTOVOLTAIC DISCONNECT." THE LABEL SHALL BE CONSTRUCTED OF Pi AC oC WITH RAPID SYSTEM SHUTDOWN
DO NOT TOUCH TERMINALS. TERMINALS ON
BOTH THE UNE AND LOAD SIDES MAY BE
DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL. ENERGIZED IN THE OPEN POSITION. I
LOCATION:AC DISCONNECT(S)